Overview

Download & View 5g Solution Overview as PDF for free.

More details

  • Words: 1,414
  • Pages: 24
Loading documents preview...
Etisalat & Ericsson 5G cooperation and knowledge sharing sessions

5G

5G Final topology, NSA option 3x Antenna 2G/3G/4G

NR AIR6488 B42

5G/4G NSA

5G E/// EPC + UDC

eCPRI

OLT

gNB BB6630 (midBand)

GPON 10G SFTP+

eNB BB5216 (800,2100) Intelligent Connectivity

1G

DUW

10G

PE

Router 6471 +TDM1001 ML

E1

DUG

TCU

NGS Sych

Add 5G in co-loc w/ 4G site in NSA with band 4G, FDD

• •

• • Ericsson Internal | 2018-02-21

GPS GM Synch

1G

10G

DUS

WNC Pocket Router

IP/MPLS

PE

For FOA sites (B42), anchoring band will be B1 or B20

Replace TCU/SIU with R6471 with Time/Phase Synch source (GPS GM, 1588v2) and 10Gbps ports Both scenarios are shown here; GPON and MW. Dark fiber to be considered for some sites as well

R6471+TDM1001 Connectivity GPON/Dark Fiber BH

ENM LTE2300 LTE1800

1/1 1/2

3G2100

1/5

3G900

1/9

5G

BSC

1/10

1/3

GPON

R6471 DAS VRF

PE-AGG

IP/MPLS

1/4

RNC

TDM1001

EPC

RJ45 2G DUG 2018-08-12 | Ericsson Internal | Page 7

1G SFP 10G SFP E1 Cable

5G New hardware

BaseBand 6630

AIR 6488 Router6471 + TDM1001

2018-08-12 | Ericsson Internal | Page 10

AIR 6488 — Advanced Antenna System (AAS) — 64TX/64RX with 128 AE (B42 with 192 AE) — Up to 200W — EIRP upto 76 dBm — Up to 100 MHz IBW — Up to 3 carriers NR and/or LTE (band dependent) — Max total carrier BW is 100MHz for NR, or 60MHz for LTE — 3 x 10 Gbps eCPRI — Weight: ~ 45 kg — Size (H x W x D): ~ 810 x 400 x 200 mm (band depended) — -48 VDC — -40 to +55 ̊C

2018-08-12 | Ericsson Internal | Page 11

R6471+TDM1001 Connectivity GPON/Dark Fiber BH

GPS 3G2100

GPON 5G

LTE2300

LTE1800

DUG1_18 DUG1_9

3G900

DUG2_9

RJ45 1G SFP 10G SFP E1 Cable 2018-08-12 | Ericsson Internal | Page 8

AIR 6488 B42

AIR 6488 B43

Technical Specification

Technical Specification

Antenna Elements Antenna Branches Antenna Matrix (row x col) Band – B42D (FOA) Band –B42F IBW Output Power Power Consumption Weight Dimensions Type of cooling CEPT compliance Multi-layer MU MIMO:

Antenna Elements Antenna Branches Antenna Matrix (row x col) Band

128 64T64R 8 x 8, (2x1 subarray) 3600-3800Mhz

IBW Output Power Power Consumption Weight Dimensions Type of cooling CEPT compliance Multi-layer MU MIMO:

100 MHz 200 W <1200 W ~45 Kg 800*400*150 Passive

128 64T64R 8 x 8, (2x1 subarray) 3500-3600Mhz 3420-3600Mhz 100 MHz 200 W <1200 W ~45 Kg 800*400*150 Passive Up to 16 layers

Up to 16 layers

NOTE: AIR B42D will be the 1st available in Q3/4, then B42F and B43 in late Q4 AIR6488, BB6630, Router 3 x AIR6488 1x Baseband 6630 Router 6471/2 Total/5G 3sectors 2018-08-12 | Ericsson Internal | Page 12

Typical Max (W) (W) 1200 120 180 35 60

Power Fuse Rating(A) supply -48V DC 3*40 (min 50max) -48V DC 1*30 -48V DC 1*6

Total Power Consumption (W) 4200 180 60 4440

BASEBAND 6630

AIR 6488 Outdoor Installation Environments to Avoid The AIR unit is designed for outdoor use but to ensure optimal operation, avoid the following: • Hot microclimates caused by, for example, heat radiated or reflected from dark or metallic walls or floors . • Chimney mouths or ventilation system outlets • Large glass or concrete surfaces . Avoid radio interference by keeping the area directly in front of the antenna clear of the following: • Metal surfaces or objects such as railings, ladders, or chains . • Equipment generating electromagnetic fields, for example, electric motors in air conditioners or diesel generators . • RBS equipment

2018-08-12 | Ericsson Internal | Page 13

Hardware & Power

AIR Unit Fuse and Circuit Breaker Recommendations

AIR Unit Parts

2018-08-12 | Ericsson Internal | Page 14

AIR 6488 Unit Connection Interfaces

2018-08-12 | Ericsson Internal | Page 15

AIR 6488 Optical Indicators The AIR unit is equipped with optical indicators that show the system status.

2018-08-12 | Ericsson Internal | Page 16

Baseband 6630

— Optimized for main-remote configurations — — — — — — —

19 inch wide, 1U high, <352mm deep 15 SFP/SFP+ for CPRI inter-connect to Radio Units reducing the need for Baseband R503 2 optical 1/10Gbps SFP/SFP+ ports and 2 electrical 1Gbps RJ45 ports Eight External Alarm ports Dual 48V DC power feeding Self-contained environmental control & field replaceable fan unit Hardware Prepared for NR (5G) and eCPRI

2018-08-12 | Ericsson Internal | Page 17

comparison

Baseband

6620/30

Main Unit 6601

Baseband

5212/16

Baseband R503

Baseband Main Unit (6601) + Baseband 5216/5212 + dummy OR Baseband Main Unit (6601) + Baseband 5216/5212 + Baseband R503

› Baseband 6630/20 is standalone & has its own climate control › Baseband 6630/20 has 15 CPRI ports & dual power feeding › Typical power consumption estimated to (at 25°C and typical load) Baseband 6630: 123W Baseband 6620: 93W

2018-08-12 | Ericsson Internal | Page 18

› The RBS 6000 chassis is mandatory for Baseband 5216/12 › Baseband R503 needed to increase number of CPRI ports › Baseband 6630 will have > 50W lower power consumption compared to the corresponding Baseband Main Unit (6601) + Baseband 5216 + Baseband R503 configuration

HWAC to enable more than 6 CPRI ports

BB6630 Mounting —In controlled environments —Mounting in 19 inch racks or in Transmission (TM) compartment in Ericsson enclosures SCU

PCF SHU

PDU

D D U U x x

R R R R R R U U U U U U S S S S S S

Cable management

PDU Air restrictor plate incl CM

3.5U subrack

TCU 04

TM Space

2018-08-12 | Ericsson Internal | Page 19

BB6630 Front & rear view

2018-08-12 | Ericsson Internal | Page 20

BB6630 Front panel Interfaces

2018-08-12 | Ericsson Internal | Page 21

BB6630 Factory & power reset

— Use a pen to press down the Factory Reset Button for more than 8 seconds. Wait until the unit has been restarted and the Operational optical indicator once again is flashing slowly at 0.5 Hz, before releasing the button 2018-08-12 | Ericsson Internal | Page 22

BB6630 installation

• The standard brackets are movable and can be placed in two different positions to adjust the baseband unit in the right position in the hosting rack. • When installing the baseband unit in an RBS, make sure to have the brackets in the 50 mm position. • For cooling purposes the minimum free space is 30 mm behind the baseband unit. 2018-08-12 | Ericsson Internal | Page 23

GROUNDING

• Ground the baseband unit by connecting it to an grounding cable. • If the unit is installed in an RBS or Enclosure, the grounding cable is not required. 2018-08-12 | Ericsson Internal | Page 24

Router 6471

Indoor small site router

— — — — — — — — — — —

30G Full Duplex Forwarding Capacity 2x1/10G SFP+, 4x1G SFP, 4x1G RJ-45 2 Gbps IPSec ⃰ 128 L3VPN, 768 PW 8Gb packet buffer, 512 queues 1RU, 33W(TYP) 219 mm x 41mm x 220mm (250mm depth with optional fan) -40ºC to 65ºC Passive cooling with optional fan accessory for temp above 55C Advance sync features Programmability and SDN support

Hardened and cost effective CSR for emerging market and suburban sites.

⃰ HW prepared for 8 Gbps 2018-08-12 | Ericsson Internal | Page 25

6471 interfaces & capacity

4x 100/1000 Base-T RJ45 ports

Synchronization interfaces: 1x RJ45 port 1PPS+TOD (ITU-T G.703) 1x RJ45 console port 1x USB 2.0 port

Dual power feed 2x GE/10GE SFP+ ports 4x GE SFP ports 1x RJ45 Alarm port for 3 input and 1 output alarm contacts 2018-08-12 | Ericsson Internal | Page 26

1x GE Base-T Ethernet for out-of-band management

TDM 1001

E1 CES/ABIS expansion module

— — — — — — — — —

8xE1/T1 Abis over IP 16 x T1/E1 CES 1 x GigE RJ-45/SFP combo port 1 x Ethernet management port 1RU, 20W(TYP) 219 mm x 41mm x 220mm -40ºC to 65ºC, Passive cooling Managed as Attached Unit of any indoor Router 6000 variants (e.g. No seperate IP address) — Can be installed in the same 1RU hosting shelf next to Router 6471

Hosting Shelf 1RU

Router 6471

2018-08-12 | Ericsson Internal | Page 27

19”

TDM 1001

TDM 1001 interfaces & capacity

8x RJ45 ports for up to 16x E1/T1 interfaces 1x GE Base-T Ethernet for out-of-band management

Dual power feed

1x GE SFP 1x 100/1000 Base-T RJ45 ports 2018-08-12 | Ericsson Internal | Page 28

1x RJ45 console port

Ericsson.com

Related Documents

5g Solution Overview
January 2021 0
5g
January 2021 2
5g Introduction
February 2021 0
5g Beamforming
March 2021 0
Ddr Overview
February 2021 1
Infovista Planet 5g Nr
February 2021 0

More Documents from "Denmark Wilson"

Full Thesis.pdf
February 2021 1
5g Solution Overview
January 2021 0
Payslip Cognizant Mar 2018
February 2021 1
Electrical Checklist
January 2021 1