REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

UTILITY ALTA PRESION

INSPECTOR ING. FREDY CAMARGO

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

INSPECTION DATE

SERIAL NUMBER

18 Abril, 2013

NA

SITE

RIG

MODEL

SOPO

SAI 15 INSPECTION TYPE

NA

CUSTOMER SAN ANTONIO INTERNACIONAL

BOROCOPE INSPECTION

SITE CONTACTO ING. –JUAN DIEGO RENDON JEFE DE MANTENIMIENTO -SOPO

ALCANCE Este reporte describe y documenta la inspección boroscópicade 5Manguerasde alta presión, realizada el 2 de Septiembre de 2013 correspondientes al SAI 15. El propósito de esta inspección boroscopica fue buscar las condiciones consideradas anormales en la sección interna de la manguera. FOTOGRAFIAS Las fotografías incluidas en este reporte son las que mejor representan la condición interna de la Manguera. Las fotografías seleccionadas muestran las áreas problema y las vistas típicas de los componentes observados y se incluyen como parte de éste reporte para su documentación.

OBSERVACIONES Ver Tabla 1.”Resultados de inspección visual” y registros de inspección.

Ing. Fredy Camargo Inspector NDT Amcol Ingeniería Ltda http://www.amcolingenieria.com

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

TABLA 1. RESULTADOS DE INSPECCIÓN VISUAL MANGUERA

SAI

1

15

SERIE No. Fecha NLB032R S

ID HOS E (IN)

A (in)

B (in)

3.5

9

980

C (in)

9

LONG. HOSE (in)

FECHA DE PRUEBA

998

18/04/2013

CONDICION EXTERNA

-MARCAS DE CORTE -PERDIDAS DE MATERIAL

CONDICION INTERNA

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

VER REGISTRO No.

1-4

1-12 EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES 2

15

15220 7-2001

3.5

11

430

11

442

18/04/2013

-OK

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

4-8

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES 3

15

17184 1-03

3.5

9

174

9

192

18/04/2013

MARCAS DE CORTE -PERDIDAS DE MATERIAL

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

9-12

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES 17122 4

15

3.5

11

134

11

146

18/03/2013

MARCAS DE CORTE -PERDIDAS DE MATERIAL

-PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

13-16

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES 17138 5

15

3.5

11

134

11

146

18/04/201 3

MARCAS DE CORTE -PERDIDAS DE MATERIAL

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA. EL REVESTIMIENTO INTERNO PRESENTA PIZADURAS

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

17-20

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

FIGURA 1. COFLEXIP

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

MANGUERA 1 SAI 15 SN: NLB032RS

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 1

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

REGISTRO 2

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 3

COMENTARIOS .

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

REGISTRO 4

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

MANGUERA 2 SAI 15 SN: 15220

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 5

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

REGISTRO 6

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 7

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

REGISTRO 8

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

MANGUERA 3 SAI 15 SN: 17184

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 9

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

REGISTRO 10

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 11

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

REGISTRO 12

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

MANGUERA 4 SAI 15 SN: 17122

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 13

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

REGISTRO 14

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 15

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

REGISTRO 16

COMENTARIOS

.

EL REVESTIMIENTO INTERNO NO PRESENTA CONDICIONES ANORMALES.

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

O. S. No. : 410 Reporte No.: 03 Fecha: 2-SEP/2013

MANGUERA 5 SAI 15 SN: 17138

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 17

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

PRESENTA CORROSION EN LOS BORDES DE CONEXIÓN SECCION INTERNA.

REGISTRO 18

COMENTARIOS

EL REVESTIMIENTO INTERNO PRESENTA PICADURAS

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]

REPORTE DE INSPECCION POR BOROSCOPIA EN MANGUERAS SAN ANTONIO INTERNACIONAL

O. S. No. : 410

Para: ING. –JUAN DIEGO RENDON- JEFE MANTENIMIENTO. SAN ANTONIO INTERNACIONAL

REGISTRO 19

Reporte No.: 03 Fecha: 2-SEP/2013

COMENTARIOS

EL REVESTIMIENTO INTERNO PRESENTA PICADURAS.

REGISTRO 20

COMENTARIOS

EL REVESTIMIENTO INTERNO PRESENTA PICADURAS

Carrera 49B # 91 – 54 Telefax: (571) 621 86 34 – 621 86 61 – Cel: (03 310) 212 49 39 Bogotá, D.C. – Colombia – e-mail: [email protected]