Diagrama De Flujo Del Procedimiento De Control De Calidad Para Un Diagnostico De Culata

  • Uploaded by: german lizarazu
  • 0
  • 0
  • January 2021
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Diagrama De Flujo Del Procedimiento De Control De Calidad Para Un Diagnostico De Culata as PDF for free.

More details

  • Words: 358
  • Pages: 4
Loading documents preview...
NOMBRE: GERMAN LIZARAZU VASQUEZ CODIGO: 12048 DIAGRAMA DE FLUJO DEL PROCEDIMIENTO DE CONTROL DE CALIDAD PARA UN DIAGNOSTICO DE CULATA

INICIO

DESARME DE LA CULATA

EXTRAER VALVULAS

INSTALAR PRENSA PARA RETIRAR VALVULAS EN UNO DE LOS ORIFICIOS DE ½-13 X 5.5” EN UNA SUPERFICIE RESISTENTE Y PLANA ACOPLAR EL RETENEDOR DE RESORTES Y COMPRIMIR LOS RESORTE DE LA VALVULA EXTRAER LAS CUÑAS CONICAS DE SUJECION ENTRE EL VASTAGO DE LA VALVULA Y EL RETENEDOR O CAZUELA DE RESORTES

RETIRAR LOS RETENEDORES, LOS RESORTES, LAS ARANDELAS Y LOS SELLOS DE VALVULA

EXTRAER LAS CUÑAS CONICAS DE SUJECION ENTRE EL VASTAGO DE LA VALVULA Y EL RETENEDOR O CAZUELA DE RESORTES LEVANTAR LA CULATA

LA VALVULA SE DESLIZA POR LA GUIA SI

NO

NOMBRE: GERMAN LIZARAZU VASQUEZ CODIGO: 12048

DAR UN GOLPE MODERADO CON MARTILLO DE GOMAEN EL VASTAGO DE LA VALVULA SOLDAR UNA VALVULA A REMPLAZAR EN EL ASIENTO QUE SE VA A RETIRAR

INSTALAR LA CULATA EN UNA PRENSA HIDRAULICA DEJANDO LA SUPERFICIE INFERIOR HACIA ABAJO EXTRAER ASIENTOS DE LAS VALVULAS

RETIRAR LAS GUIAS CON UN EXTRACTOR DE GUIAS

LIMPIAR LA SUPERFICIE PLANA DE LA CULATA CON UNA PULIDORA

INTRODUCIR LA CULATA EN UN HORNO PARA REALIZAR EL LAVADO QUIMICO A ALTA PRESION CON SODA CAUSTICA A 80°C DURANDE 60 MINUTOS

PRUEBA HIDRONEUMATICA

UTILIZAR PLATINAS Y EMPAQUES DE CAUCHO PARA SELLAR LA CULATA

SI

NO

NOMBRE: GERMAN LIZARAZU VASQUEZ CODIGO: 12048 FABRICAR PLATINAS DE ¾” A 1”

CORREGIR FUGAS DE AGUA

NO

SELLAR CIRCUITOS DE REFRIGERACION DE LA CULATA

SI PONER A CIRCULAR AGUA POR LA CULATA

TEMPERATURA DE LA CULATATA

SI

SE FINALIZA LA CIRCULACION DE AGUA Y SE INYECTA AIRE

INSPECCION VISUAL DE LA CULATA PARA EVIDENCIAR POSIBLES GRIETAS

PRUEBA DE TINTAS PENETRANTES

APLICAR REMOVEDOR O LIMPIADOR SOBRE EL AREA DE PRUEBA

NO

DEJAR CIRCULAR EL AGUA POR LA CULATA HASTA QUE LLEGUE A LA TEMPERATURA REQUERIDA

NOMBRE: GERMAN LIZARAZU VASQUEZ CODIGO: 12048

ROCIAR EL AREA DE PRUEBA CON TINTA PENETRANTE Y ESPERAR 10 A 30 MINUTOS

APLICAR REMOVEDOR O LIMPIADOR SOBRE EL AREA DE PRUEBA PARA RETIRAR LA TINTA PENETRANTE

INSPECCIONAR EL AREA DE PRUEBA PARA VER SI HAY ROTURAS

NO

SI

DESCARTAR CULATA

FIN

Related Documents


More Documents from "Eduardo Ribera Bruno"