DOSIMETER KIMIA

KELOMPOK 6 • ANNISA NOVA • ARANSCA VANESSA

• ENY YUDIA L • FAISAL UTAMA • NASRULLAH KHADAFI

• NINA NURAENI

PENDAHULUAN DOSIMETRI MERUPAKAN KEGIATAN PENGUKURAN DOSIS RADIASI DENGAN TEKNIK PENGUKURAN DIDASARKAN PADA PENGIONAN YANG DISEBABKAN OLEH RADIASI DALAM SUATU BAHAN/MATERI. UNTUK MENGUKUR BESARNYA ENERGI RADIASI YANG DISERAP OLEH MATERI PERLU DIPERKENALKAN SUATU BESARAN YANG TIDAK TERGANTUNG PADA JENIS RADIASI, ENERGI RADIASI, MAUPUN SIFAT BAHAN PENYERAP, TETAPI HANYA BERGANTUNG PADA JUMLAH ENERGI RADIASI YANG DISERAP PERSATUAN MASSA BAHAN YANG MENERIMA PENYINARAN RADIASI TERSEBUT.

ADA BEBERAPA METODE YANG DAPAT DIGUNAKAN UNTUK MENGUKUR DOSIS SERAP DARI RADIASI. DOSIMETER STANDAR DAPAT DIGUNAKAN UNTUK MENENTUKAN NILAI DOSIS SECARA LANGSUNG. ADA TIGA JENIS DOSIMETER STANDAR YANG DIMANFAATKAN UNTUK DOSIMETRI RADIASI .RADIASI YANG DITERIMA TIDAK DAPAT LANGSUNG TERUKUR KARENA MANUSIA ATAUPUN LINGKUNGAN TIDAK PUNYA VARIABEL YANG MENUNJUKKAN BERAPA BESARNYA DOSIS YANG DITERIMA, MELAINKAN TERJADI PERUBAHAN YANG BERUPA EFEK KIMIA MAUPUN FISIKA DARI MATERI YANG TERKENA RADIASI. EFEK KIMIA INILAH YANG DIGUNAKAN SEBAGAI PENGUKUR DOSIS ATAU LAJU DOSIS RADIASI . PROSES KIMIA TERSEBUT

PEMBAHASAN • DOSIMETRI DAN DOSIMETER 1. DOSIMETRI DOSIMETRI ADALAH ILMU YG MEMPELAJARI BERBAGAI BESARAN DAN SATUAN DOSIS RADIASI. SEDANGKAN DOSIS ADALAH KUANTITAS DARI PROSES YANG DITINJAU SEBAGAI AKIBAT RADIASI MENGENAI MATERI. 2. DOSIMETER DOSIMETER DIGUNAKAN UNTUK MENDETEKSI DAN MENGUKUR DOSIS INDIVIDU DARI RADIASI EKSTERNAL. DOSIMETER DIGUNAKAN UNTUK MENGUKUR DOSIS RADIASI EKSTERNAL DAN TIDAK MEMBERIKAN PERLINDUNGAN TERHADAP PAPARAN RADIASI.

DOSIMETER KIMIA BERIKUT INI DIKEMUKAKAN PENJELASAN DARI KETIGA JENIS DOSIMETER KIMIA SERING DIMANFAATKAN UNTUK DOSIMETRI RADIASI- DOSIS TINGGI. YAITU :

1. DOSIMETER FRICKE 2. DOSIMETER FERRO–CUPRI SULFAT 3. DOSIMETER CERI-CERO SULFAT

1. DOSIMETER FRICKE DOSIMETER FRICKE MERUPAKAN SALAH SATU JENIS PENGUKUR DOSIS SERAP YANG DIPAKAI SEBAGAI DOSIMETER ACUAN KARENA ABSORBSINYA YANG TINGGI DAN MEMPUNYAI HUBUNGAN YANG LINIER TERHADAP DOSIS SERAP. DOSIMETER FRICKE DIBUAT DENGAN CARA MELARUTKAN 0,392G FE(NH4)2 (SO4) 2.6 H2O (FERRO AMMONIUM SULFAT) DAN 0,058G NACL (NATRIUM CLORIDA) DALAM 12,5ML 0,8N H2SO4 (ASAM SULFAT). LARUTAN DIENCERKAN HINGGA MENJADI SATU LITER DENGAN 0,8N H2SO4 PADA SUHU 25°C (KADAR LARUTAN ADALAH 0,001M FERRO AMMONIUM SULFAT, 0,001M NATRIUM CLORIDA DAN 0,8N ASAM SULFAT). LARUTAN 0,8N ASAM SULFAT DIBUAT DENGAN CARA MELARUTKAN 22,5 ML ASAM SULFAT PEKAT DALAM AIR DESTILAT SEHINGGA MEMBENTUK SATU LITER LARUTAN. PROSES IRRADIASI DAPAT MENGHASILKAN OKSIDASI ION FE2+ MENJADI FE3+. OKSIDASI INI AKAN MENYEBABKAN TERJADINYA PERUBAHAN RAPAT OPTIK PADA LARUTAN DOSIMETER SEHINGGA DAPAT DIMANFAATKAN UNTUK PENGUKURAN RADIASI. JUMLAH ION FERRI YANG TERBENTUK SEBANDING DENGAN BESAR PERUBAHAN RAPAT OPTIK DAN DAPAT DIUKUR SECARA TELITI DENGAN METODE SPEKTROFOTOMETRI. PENGUKURAN DILAKUKAN DENGAN PERALATAN

KEUNGGULAN DARI DOSIMETER FRICKE INI ANTARA LAIN : 1. APABILA LAJU DOSIS DARI SUMBER YANG DIUKUR TIDAK MELEBIHI 2 X 107 GY/S DAN TEMPERATUR TIDAK MENYIMPANG SELAMA PROSES IRRADIASI, MAKA LAJU DOSIS SUMBER TIDAK BERPENGARUH TERHADAP HASIL PENGUKURAN. 2. TINGKAT PERUBAHAN RAPAT OPTIS PADA PEMANTAU FRICKE CUKUP LINIER DENGAN DOSIS RADIASI YANG DITERIMA, SEHINGGA PERHITUNGAN DOSISNYA DAPAT DILAKUKAN MENGGUNAKAN SUATU FACTOR KONVERSI YANG MENUNJUKKAN HUBUNGAN ANTARA DOSIS DAN TINGKAT PERUBAHAN RAPAT OPTIS LARUTAN. 3. KEAKURATAN PENGUKURAN RADIASI DENGAN PEMANTAU FRICKE TIDAK TERPENGARUH OLEH VARIASI TEMPERATUR SISTEM ANTARA 1°C SAMPAI DENGAN 60°C SELAMA PROSES IRRADIASI.

KELEMAHAN DOSIMETER FRICKE : • HARUS DIGUNAKAN BAHAN-BAHAN KIMIA DENGAN TINGKAT KEMURNIAN YANG SANGAT TINGGI SERTA SEMUA PERALATAN YANG DIPERGUNAKAN HARUS BENAR-BENAR BERSIH UNTUK MENDAPATKAN SISTEM PEMANTAU YANG BAIK .

2. DOSIMETER FERRO–CUPRI SULFAT DOSIMETER FERRO-CUPRI SULFAT DIBUAT DENGAN CARA MELARUTKAN 0,392 G FE(NH4)2(SO4)2.6H2O (FERRO AMMONIUM SULFAT) DAN 2,50 G CUSO4.5 H2O (CUPRI SULFAT) DALAM 12,5 ML 0,8N H2SO4. LARUTAN SELANJUTNYA DIENCERKAN HINGGA VOLUMENYA MENJADI SATU LITER DENGAN MENAMBAHKANAIR TRIDEST. PROSES KERJA PEMANTAU FERROCUPRI SULFAT JUGA BERDASARKAN PADA PRINSIP OKSIDASI ION FERRO MENJADI FERRI KARENA RADIASI PENGION. PEMANTAU INI SERUPA DENGAN PEMANTAU FRICKE,NAMUN KEPEKAANNYA BERKURANG DENGAN PENAMBAHAN CUPRI SULFAT PADA LARUTAN, SEHINGGA DAPAT DIMANFAATKAN UNTUK PENGUKURAN RADIASI DENGAN DOSIS YANG LEBIH TINGGI. PERUBAHAN RAPAT OPTIS PADA LARUTAN FESO4 + CUSO4 KARENA OKSIDASI OLEH RADIASI PENGION DIUKUR MENGGUNAKAN

PENGUKURAN KADAR ION FERRI MELALUI SPEKTROFOTOMETRI INI DILAKUKAN PADA PANJANG GELOMBANG 305 NM. SEPERTI HALNYA PEMANTAU FRICKE, TANGGAPAN YANG DIHASILKAN OLEH PEMANTAU FERRO-CUPRI SULFAT INI JUGA LINIER TERHADAP DOSIS RADIASI YANG DITERIMA. OLEH SEBAB ITU, PERHITUNGAN DOSIS RADIASI DAPAT DILAKUKAN MENGGUNAKAN FAKTOR KONVERSI YANG MENUNJUKKAN HUBUNGAN ANTARA DOSIS RADIASI DAN TANGGAPAN. KETELITIAN DARI METODE INI TIDAK TERPENGARUH OLEH VARIASI TEMPERATUR ANTARA 20–60°C SELAMA PROSES IRRADIASI. TANGGAPAN YANG DIHASILKANNYA JUGA TIDAK BERGANTUNG PADA SPEKTRUM ENERGI RADIASI DARI 0,1–10 MEV.

KEUNGGULAN DOSIMETER FERRO–CUPRI SULFAT : 1.

JANGKAUAN KEMAMPUAN PENGUKURANNYA HINGGA MENCAPAI 20 KALI LEBIH TINGGI DIBANDINGKAN DENGAN KEMAMPUAN DOSIMETER FRICKE.

2.

TINGKAT PERUBAHAN RAPAT OPTIS DOSIMETER FERRO-CUPRI SULFAT TIDAK TERPENGARUH OLEH LAJU DOSIS RADIASI YANG DITERIMANYA.

KELEMAHAN DOSIMETER FERRO–CUPRI SULFAT : 1.

LARUTAN DOSIMETER FERRO-CUPRI SULFAT INI BERSIFAT SANGAT TIDAK STABIL SEHINGGA HARUS DIPERBAHARUI SETIAP HARI.

3. DOSIMETER CERI-CERO SULFAT DOSIMETER CERI-CERO SULFAT MERUPAKAN SISTIM PEMANTAU RADIASI DOSIS TINGGI YANG SUDAH SEJAK LAMA DIKENAL. . DOSIMETER CERI-CERO SULFAT UNTUK MENGUKUR DOSIS TINGGI DENGAN JANGKAUAN 10–1000 KGY SUDAH UMUM DIGUNAKAN DALAM PROSES RADIASI. LARUTAN CERI SULFAT DIBUAT MENGGUNAKAN REAGEN CE(SO4)24H2O, H2SO4 DAN H2O2 30 % YANG DILARUTKAN DALAM PELARUT TRIDES. APABILA LARUTAN CERI-CERO SULFAT DISINARI DENGAN GAMMA DOSIS TINGGI, MAKA AKAN TERJADI PROSES REDUKSI ION CERI (CE 4+) MENJADI ION CERO (CE3+). KARENA ITU, SISTIM PEMANTAU INI DIKENAL DENGAN NAMA CERI-CERO SULFAT. SEMAKIN BESAR DOSIS RADIASI, SEMAKIN BANYAK PULA ION CERI YANG TEREDUKSI MENJADI CERO. OLEH SEBAB ITU AKAN TERDAPAT PERBEDAAN JUMLAH ION CERO PADA LARUTAN YANG DIIRADIASI DENGAN LARUTAN YANG TIDAK DIIRADIASI. PERUBAHAN KERAPATAN OPTIK PADA DOSIMETER CERICERO YANG TELAH DIRADIASI DIUKUR MENGGUNAKAN SPEKTROFOTOMETER UV-VISIBLE PADA PANJANG GELOMBANG 320 NM. PENGUKURAN KADAR ION CERO DAPAT PULA DILAKUKAN MELALUI PENGUKURAN BEDA POTENSIAL ELEKTROKIMIA ANTARA LARUTAN

KEUNGGULAN DOSIMETER CERI-CERO SULFAT : 1. DOSIMETER CERI-CERO TELAH DITETAPKAN OLEH ICRU SEBAGAI DOSIMETER ACUAN KARENA CUKUP STABIL SEBELUM DAN SESUDAH IRRADIASI SERTA MEMILIKI KETELITIAN YANG SANGAT BAIK (± 1 %). 2. DOSIMETER CERI-CERO SULFAT LEBIH PEKA TERHADAP PENGOTOR DIBANDINGKAN PEMANTAU FRICKE.

KELEMAHAN DOSIMETER CERI-CERO SULFAT : 1.

SISTIM PEMANTAU JUGA MEMILIKI WAKTU HIDUP YANG TERBATAS, KIRA-KIRA HANYA SATU BULAN.

2. SEPERTI HARUS DIGUNAKANNYA BAHAN-BAHAN KIMIA DENGAN TINGKAT KEMURNIAN YANG SANGAT TINGGI SERTA SEMUA PERALATAN YANG DIPERGUNAKAN HARUS BENAR-BENAR BERSIH UNTUK MENDAPATKAN SISTIM PEMANTAU YANG BAIK.





SEKIAN & TERIMAKASIH

Related Documents

Dosimeter Kimia
January 2021 1
Kimia
February 2021 3
Makalah Kimia
January 2021 0
Kimia Medisinal
January 2021 1
Rangkuman Rumus Kimia
February 2021 0

More Documents from "Agus Darmadi Sala"

Dosimeter Kimia
January 2021 1
February 2021 0
Serotonin
February 2021 0
Saxophone Jubilee
January 2021 2