Loading documents preview...
Doc Title: PUMP DATA SHEET (PDS)
PUMP DIVISION COIMBATORE
Document Rev:
Flowserve Document No.:
EX18195003_001-1003-01
Customer Name:
FLOWSERVE PERU S.A.C
FS Reference Number:
EX18195003
End User Name:
PLUSPETROL PERU CORPOTATION S.A.
Customer PO Number:
3133 & 20-JUN-18
Pump Tag No(s):
PBB-3315
Equipment Service:
NON PRESSURIZED DRAIN PUMP
Pump Size:
ECPJ 32-160-R
Quantity:
1 NOS
0
Rev
Revision Description
Created By
Checked By
Released By
Release Date
0
Issued For Approval
KS
SRR
RVS
30-Jul-18
A
30/07/2018
For Approval
REV.
DESCRIPTION
DATE
KS BY
SRR
RVS
CHK
APPD
PROJECT: PISCO DIESEL BLENDING
TITLE:
Perú Corp. S.A.
DATA SHEET FOR NON PRESSURIZED DRAIN PUMP PBB-3315 P&P FACILITIES DEPARTMENT All the information contained in this
ESC
DOCUMENT Nº:
document is confidential and property of Pluspetrol, and the totally or partial copy or reproduction of it is prohibited without previous authorization.
REVISION:
PPIS-548-HD-M-013 N/A
REPLACE TO:
0 Pag: 1 de 7
CLIENT: PROJECT:
PLUSPETROL PERU CORPORATION S.A PISCO DIESEL BLENDING Title: Page:
DATA SHEET FOR NON PRESSURIZED DRAIN PUMP PBB-3315 Code:
Perú Corp. S.A.
02 of 07
Revision:
PPIS-548-HD-M-013
0
API-610 CENTRIFUGAL PUMP PROCESS / SITE / PERFORMANCE / DRIVER DATA SHEET 1 Note APPLICABLE TO: 2
FOR
3
SITE
4
NO. REQ
5
MANUFACTURER
APPLICABLE NTL/INTNTL STANDARD:
PROPOSAL
PBB-3315 (NOTE 19)
NON PRESSURIZED DRAIN PUMP
TYPE
No. STAGES
VERTICAL
MODEL
6 7
Rev
PPIS-548-RI-M-003 TAG
SERVICE
PISCO PLANT PUMP SIZE
1
MR
API-610 11TH ED
UNIT
PLUSPETROL PERÚ CORP. S.A.
SERIAL NO.
LIQUID CHARACTERISTICS (FOR NORMAL CASE)
8
Units
9
LIQUID TYPE OR NAME :
10
VAPOR PRESSURE (NOTE 2):
11
RELATIVE DENSITY :
12
SPECIFIC HEAT : VISCOSITY (NOTE 3):
13
Maximum
Normal
Minimum
NOTE
INTERMITTENT
• IF INTERMITTENT NO. OF STARTS (NOTE 5):
0.5
values refer
PUMPS OPERATE IN:
0.89
only to the
CORROSION DUE TO : (6.12.1.9)
property
EROSION DUE TO : (6.12.1.9) H2S CONCENTRATION (ppm) : (6.12.1.12)
psia Btu/(lbm-°F) cP
SERVICE :
Max & min
HYDROCARBON
Listed
5.34
14 15
CHLORIDE CONCENTRATION (ppm) :
OPERATING CONDITIONS (6.1.2) Units
Maximum Flow
16 17
NPSHa Datum:
18
PUMPING TEMPERATURE :
Rated Flow (certified point)
°F
86
19
FLOW :
gpm
50
20
DISCHARGE PRESSURE (NOTE 8): (6.3.2)
psia
54
21
SUCTION PRESSURE :
psia
14
22
DIFFERENTIAL PRESSURE :
psi
40
23
DIFFERENTIAL HEAD :
ft
102
24
NPSHA (NOTE 12):
25
HYDRAULIC POWER :
Normal Flow
Minimum Flow
PARTICULATE SIZE (DIA IN MICRONS) PARTICULATE CONCENTRATION (PPM)
C.L. Impeller
ft
36
HP
1.1
NOTE: ALL OPERATING CONDITIONS ARE REFERED TO THE MINIMUM LIQUID CHARACTERISTICS. MAXIMUM LIQUID CHARACTERISTICS OR OTHER OPERATIONAL CASES ARE LOCATED IN THE NOTES PAGE
26 SITE AND UTILITY DATA (NOTE 6)
27 28
LOCATION:
COOLING WATER :
29
OUTDOOR
30
MOUNTED AT (NOTE 9):
31
ELECTRIC AREA CLASSIFICATION:
32
GROUP
INLET
UNHEATED
l
GRADE
TROPICALISATION REQD 6.1.22
Class I / Group D
DIVISION TEMP CLASS
Class I / Group D
33
SITE DATA :
34
ELEVATION (MSL) :
35
RANGE OF AMBIENT TEMPS:MIN / MAX
54
/
86
36
RELATIVE HUMIDITY: MIN / MAX
84
/
100
37
UNUSUAL CONDITIONS: •
TEMP
°F
2
PRESS.
psig
T3B
SOURCE
RETURN
DESIGN
MAX MIN
COOLING WATER CHLORIDE CONCENTRATION: ft
52
BAROMETER :
SPECIFY OTHER :
UTILITY CONDITIONS :
40
ELECTRICITY :
Psia
INSTRUMENT AIR :
°F
STEAM
HEATING
480
120
41
VOLTAGE
42
PHASE
3
1
43
HERTZ
60
60
CONTROL
ppm psig
DRIVERS TEMP °F
MIN
psig
HEATING
Max
Min PRESS. psig
DRIVERS
MAX
%
OTHER DUST/ MARINE COAST ENVIRONMENT (SALT MIST, SANDSTORM)
38 39
14.67
Max Min
SHUTDOWN
44 PERFORMANCE
45 46 47 48
DRIVER (7.1.5) (NOTE 16 & 17)
ECPJ 32-160-R
PROPOSAL CURVE NO.
3520
RPM
DRIVER TYPE
As Tested Curve No. IMPELLER DIA.:
49
RATED
RATED POWER
5.35
6.89 MIN.
MAX.
3.11 HP
5.31 36.80
EFFICIENCY
in.
VARIABLE SPEED REQUIRED
(%)
SOURCE OF VARIABLE SPEED
gpm
OTHER
gpm
MANUFACTURER
50
RATED CURVE BEP FLOW (at rated impeller dia)
51
MIN FLOW :
52
PREFERRED OPERATING REGION (6.1.11)
35.7
to
61.2
gpm
NAMEPLATE POWER (TO BE FILLED BY VENDOR)
53
ALLOWABLE OPERATING REGION
10.7
to
74.9
gpm
Nominal RPM
54
MAX HEAD @ RATED IMPELLER
123.72
ft
RATED LOAD RPM
55
MAX POWER @ RATED IMPELLER
3.87
HP
FRAME OR MODEL
56
NPSH3 AT RATED FLOW :
6.6
ft
ORIENTATION
57
CL PUMP TO U/S BASEPLATE
ft
LUBE
58
NPSH MARGIN AT RATED FLOW :
ft
BEARING TYPE:
59
SPECIFIC SPEED (6.1.9)
60
SUCTION SPECIFIC SPEED LIMIT
61
SUCTION SPECIFIC SPEED
62
MAX. ALLOW. SOUND PRESS. LEVEL REQD (6.1.14)
63
EST MAX SOUND PRESS. LEVEL
64
MAX. SOUND POWER LEVEL REQ'D (6.1.14)
65
EST MAX SOUND POWER LEVEL
66 67 68 69 70
MOTOR
GEAR
THERMAL
gpm
10.7
STABLE
(6.8.9)
gpm,rpm,ft
RADIAL THRUST
<12000 gpm,rpm,ft
STARTING METHOD <85 @ 1 mt (dBA) (dBA)
5
VERTICAL
/ / Open Valve (Fully-Loaded)
MOTOR TYPE ENCLOSURE TYPE SEE DRIVER DATA SHEET
TEFC
HP
CLIENT:
PLUSPETROL PERU CORPORATION S.A
PROJECT:
PISCO DIESEL BLENDING Title: Page:
DATA SHEET FOR NON PRESSURIZED DRAIN PUMP PBB-3315 Code:
Perú Corp. S.A.
03 of 07
Revision:
PPIS-548-HD-M-013
0
API 610 CENTRIFUGAL PUMP MECHANICAL DATA SHEET 2
API PUMP TYPE:
VS4
3 4
Rev
CONSTRUCTION
1 Note
NOZZLE CONNECTIONS (NOTE 3):
5
[Based on API 610 definitions]
CASING MOUNTING:
SEE ALSO PAGE 6
CASING TYPE:
(6.5.5)
OH3 BACKPULLOUT LIFTING DEVICE REQD. (9.1.2.6)
Size
Facing
Rating
Position
1.5"
RF
150
TOP
6
SUCTION
7
DISCHARGE
8
PRESSURE CASING AUX. CONNECTIONS: (6.4.3.2)
VERTICAL (6.3.10)
CASE PRESSURE RATING: MAWP :
No.
9
Size
Type
Facing
Rating
SINGLE VOLUTE
(6.3.6)
HYDROTEST :
Posn.
BALANCE/LEAK OFF
SUCT'N PRESS. REGIONS DESIGNED FOR MAWP
11
DRAIN
ROTATION:
12
VENT
•
IMPELLERS INDIVIDUALLY SECURED :
13
PRESSURE GAGE
•
BOLT OH 3/4/5 PUMP TO PAD / FOUNDATION :
14
TEMP GAGE
•
PROVIDE SOLEPLATE FOR OH 3/4/5 PUMPS
15
WARM-UP LINE
SHAFT FLEXIBILITY INDEX (SFI) (9.1.1.3) Drain Valve Supplied By
First Critical Speed Wet (Multi stage pumps only)
18
DRAINS MANIFOLDED
COMPONENT BALANCE TO ISO 1940 G1.0
19
VENT Valve Supplied By
SHRINK FIT -LIMITED MOVEMENT IMPELLERS (9.2.2.3)
20
VENTS MANIFOLDED THREADED CONS FOR PIPELINE SERVICE & < 50°C (6.4.3.2)
21
COUPLING:(7.2.3)
22
SPECIAL FITTINGS FOR TRANSITIONING (6.4.3.3)
MANUFACTURER
23
CYLINDRICAL THREADS REQUIRED (6.4.3.8)
MODEL
24
GUSSET SUPPORT REQUIRED
RATING (POWER/100 RPM)
25 VS 6 DRAIN
27
DRAIN TO SKID EDGE
N/A
(7.2.13.f)
in.
SERVICE FACTOR
> 1.5
RIGID
28
YES
COUPLING WITH HYDRAULIC FIT (7.2.10) MATERIAL (6.12.1.1) (NOTE 4)
29 30
APPENDIX H CLASS
31
MIN DESIGN METAL TEMP (6.12.4.1)
32
REDUCED-HARDNESS MATERIALS REQ'D (6.12.1.12.1)
33
Applicable Hardness Standard (6.12.1.12.3)
34
BARREL :
35
BOWL :
36
DIFFUSERS
37
IMPELLER :
38
IMPELLER WEAR RING :
39
S-1
COUPLING WITH PROPRIETARY CLAMPING DEVICE (7.2.11) COUPLING IN COMPLIANCE WITH (7.2.4)
NO NA
API 610 compliant
COUPLING GUARD STANDARD PER (7.2.13.a) Window on Coupling Guard
CARBON STEEL BASEPLATE CAST IRON
CASE WEAR RING :
40
SHAFT:
A322 GR 4140
MOUNTING :
41
Bowl (if VS-type)
CARBON STEEL
42
Inspection Class
Level 1
BASEPLATE CONSTRUCTION (7.3.14) BASEPLATE DRAINAGE (7.3.1) NON-GROUT CONSTRUCTION : (7.3.13) VERTICAL LEVELING SCREWS : LONGITUDINAL DRIVER POSITIONING SCREWS :
BEARINGS AND LUBRICATION (6.10.1.1) BEARING (TYPE / NUMBER):
l
GROUT AND VENT HOLES
45
RADIAL
SLEEVE
/
l
DRAIN CONNECTION
46
THRUST
ROLLER
/
MOUNTING PADS SIZED FOR BASEPLATE LEVELING (7.3.5)
(6.11.4)
SUPPLIED WITH :
REVIEW AND APPROVE THRUST BEARING SIZE : (9.2.5.2.4)
MOUNTING PADS TO BE MACHINED (7.3.6)
48
PROVIDE SPACER PLATE UNDER ALL EQUIPMENT FEET LUBRICATION :
(6.10.2.2) (6.11.3) (9.6.1)
OTHER
GREASE
PRESSURE LUBE SYSTEM TO ISO 10438-
50
(9.2.6.5)
N/A
ISO 10438 DATA SHEETS ATTACHED
51
Pressurized Lube Oil System mtd on pump baseplate
52
Location of Pressurized Lube Oil System mounted on baseplate :
N/A
53 INTERCONNECTING PIPING PROVIDED BY
Supplier
55 56
OIL VISC. ISO GRADE
57
CONSTANT LEVEL OILER :
58 59 60 61 62 63 64 65 66 67
YES
°F
API BASEPLATE NUMBER :
43
NO
COUPLING BALANCED TO ISO 1940-1 G6.3 (7.2.3)
S5
Carbon steel CAST IRON A426Gr.CPCA15 CAST IRON A426Gr.CPCA15
54
NO
SPACER LENGTH
26
50
°F
(VIEWED FROM COUPLING END)
17
49
°F
@
ROTOR:
16
47
@
psig
HYDROTEST OH PUMP AS ASSEMBLY
10
44
psig
VG
N/A
REMARKS :
ANSI B15.1
CLIENT:
PLUSPETROL PERU CORPORATION S.A
PROJECT:
PISCO DIESEL BLENDING Title: Page:
DATA SHEET FOR NON PRESSURIZED DRAIN PUMP PBB-3315 Code:
Perú Corp. S.A.
Revision:
PPIS-548-HD-M-013
04 of 07
0
API 610 CENTRIFUGAL PUMP DATA SHEET MECHANICAL SEAL / INSTRUMENTATION INSTRUMENTATION
1 Note 2
SEE ATTACHED API-670 DATA SHEET
3
ACCELEROMETER (7.4.2.1)
4
Number of Accelerometers
5
Mounting Location of Accelerometers
SEAL SUPPORT SYSTEM MOUNTING NO
(7.5.1.4) IDENTIFY LOCATION ON BASEPLATE
6
INTERCONNECTING PIPING BY
7
PROVISION FOR MTG ONLY
8
Number of Accelerometers
9
Mounting Location of Accelerometers FLAT SURFACE REQUIRED
12
Number of Accelerometers
13
Mounting Location of Accelerometers
MECHANICAL SEAL (6.8.1) SEE ATTACHED ISO 21049/API 682 DATA SHEET (6.10.2.11)
14 15
Supplier
(6.10.2.10)
10 11
Rev
SEAL SUPPORT SYSTEM MOUNTED ON PUMP BASEPLATE
YES
NO
ADDITIONAL CENTRAL FLUSH PORT
(6.8.9)
HEATING JACKET REQ'D.
(6.8.11)
API SEAL CODE SEAL MANUFACTURER
VIBRATION PROBES (7.4.2.2)
SIZE AND TYPE
16
PROVISIONS FOR VIB. PROBES
17
NUMBER PER RADIAL BEARING
MANUFACTURER CODE
18
NUMBER PER AXIAL BEARING
ARRANGEMENT
MONITORS AND CABLES SUPPLIED BY (7.4.2.4)
SEAL CHAMBER DATA
19 20 21 22
TEMPERATURE (7.4.2.3)
23
PROVISIONS FOR TEMP PROBES
24
RADIAL BEARING TEMP.
25 26 27 28
NUMBER PER RADIAL BEARING THRUST BEARING TEMP.
TEMPERATURE
gpm
PRESSURE
psig
FLOW
gpm
SEAL FLUSH PLAN MATERIAL SEAL FLUSH PLAN PIPING TYPE
NUMBER PER THRUST BEARING ACTIVE SIDE NUMBER PER THRUST BEARING INACTIVE SIDE
29
TEMP. GAUGES (WITH THERMOWELLS) (9.1.3.6)
30
PRESSURE GAUGE TYPE
AUXILIARY FLUSH PLAN MATERIAL AUXILIARY FLUSH PLAN PIPING TYPE
31 32
REMARKS
PIPING ASSEMBLY
33
THREADED
NO
34
FLANGED
YES
35
UNIONS
YES
36
TUBE TYPE FITTINGS
37
SOCKET WELDED
38
NECK WELDED
NO
39 40 41 42 43 HEATING AND COOLING (6.1.17)
44 45
COOLING REQ'D
46
COOLING WATER PIPING PLAN
47
COOLING WATER PIPING
48
FITTINGS
49
COOLING WATER PIPING MATERIALS
50
COOLING WATER REQUIREMENTS:
51
BEARING HOUSING
gpm
52
HEAT EXCHANGER
gpm
53
TOTAL COOLING WATER
54
HEATING MEDIUM
55 56
gpm
OTHER HEATING PIPING
57 PIPING & APPURTENANCES
58 59
MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)
60
VENT
61
DRAIN
62
COOLING WATER
63
TAG ALL ORIFICES (7.5.2.4)
64
SOCKET WELD CONN ON SEAL GLAND (7.5.2.8)
65 66 67 68
N/A YES NO
CLIENT: PROJECT:
PLUSPETROL PERU CORPORATION S.A PISCO DIESEL BLENDING Title: Page:
NON PRESSURIZED DRAIN PUMP PBB-3315 Code:
Perú Corp. S.A.
Revision:
PPIS-548-HD-M-013
05 of 07
0
API 610 CENTRIFUGAL PUMP DATA SHEET PAINT / TESTS / OTHER REQUIREMENTS SURFACE PREPARATION AND PAINT
1 Note 2
MANUFACTURER'S STANDARD
3
OTHER (SEE BELOW)
4
SPECIFICATION NO.
TEST (NOTE 14) NO
SHOP INSPECTION (8.1.1)
YES
PERFORMANCE CURVE
Rev
& DATA APPROVAL PRIOR TO SHIPMENT.
AS PER "PPIS-548-RI-M-003" PARAGRAPH 6.6
5
TEST WITH SUBSTITUTE SEAL (8.3.3.2.b)
6
PUMP:
7
PUMP SURFACE PREPARATION
MATERIAL CERTIFICATION REQUIRED
8
PRIMER
9
FINISH COAT
CASING (6.12.1.8)
AS PER "PPIS-548-RI-M-003" PARAGRAPH 6.6
IMPELLER SHAFT OTHER
10
CASTING REPAIR WELD PROCEDURE APPR REQD (6.12.2.5)
BASEPLATE:
(6.12.3.1)
11
BASEPLATE SURFACE PREPARATION
INSPECTION REQUIRED FOR CONNECTION WELDS (6.12.3.4.d)
12
PRIMER:
13
FINISH COAT
RADIOGRAPHY
14
DETAILS OF LIFTING DEVICES
LIQUID PENETRANT
(6.12.3.4.e)
MAG PARTICLE
15
ULTRASONIC
16
SHIPMENT: (8.4.1)
17
EXPORT BOXING REQUIRED
YES
MAG PARTICLE
18
OUTDOOR STORAGE MORE THAN 6 MONTHS
YES
RADIOGRAPHY
19
SPARE ROTOR ASSEMBLY PACKAGED FOR:
20
ROTOR STORAGE ORIENTATION (9.2.8.2)
HARDNESS TEST REQUIRED (8.2.2.7)
21
SHIPPING & STORAGE CONTAINER FOR VERT STORAGE (9.2.8.3)
ADDNL SUBSURFACE EXAMINATION (6.12.1.5) (8.2.1.3)
(NOTE 13)
INSPECTION REQUIRED FOR CASTINGS
EXPORT
LIQUID PENETRANT ULTRASONIC
22
FOR
23
N2 PURGE (9.2.8.4)
24
SPARE PARTS
METHOD
25
START-UP
YES
26
NORMAL MAINTENANCE
YES
PMI TESTING REQUIRED (8.2.2.8)
27 28
lb
WEIGHTS ITEM No
PUMP
DRIVER
COMPONENTS TO BE TESTED RESIDUAL UNBALANCE TEST (J.4.1.2)
GEAR
BASE
TOTAL
29
NOTIFICATION OF SUCCESSFUL SHOP PERFORMANCE TEST (8.1.1.c) (8.3.3.5)
30
BASEPLATE TEST (7.3.21)
31
HYDROSTATIC
32
HYDROSTATIC TEST OF BOWLS & COLUMN (9.3.13.2) OTHER PURCHASER REQUIREMENTS
33 34
COORDINATION MEETING REQUIRED (10.1.3)
35
MAXIMUM DISCHARGE PRESSURE TO INCLUDE
PERFORMANCE TEST YES
TEST IN COMPLIANCE WITH (8.3.3.2) TEST DATA POINTS TO (8.3.3.3)
36
MAX RELATIVE DENSITY
37
OPERATION TO TRIP SPEED
38
MAX DIA. IMPELLERS AND/OR NO OF STAGES
YES
TEST TOLERANCES TO (8.3.3.4) NPSH (8.3.4.3.1) (8.3.4.3.4) NPSH-1ST STG ONLY (8.3.4.3.2)
39
CONNECTION DESIGN APPROVAL (9.2.1.4)
NO
NPSH TESTING TO HI 1.6 OR ISO 9906 (8.3.4.3.3)
40
TORSIONAL ANALYSIS / REPORT (6.9.2.10)
NO
TEST NPSHA LIMITED TO 110% SITE NPSHA (8.3.3.6)
41
PROGRESS REPORTS
YES
RETEST ON SEAL LEAKAGE (8.3.3.2.d)
42
OUTLINE OF PROC FOR OPTIONAL TESTS (10.2.5)
RETEST REQUIRED AFTER FINAL HEAD ADJ (8.3.3.7.b)
43
ADDITIONNAL DATA REQUIRING 20 YEARS RETENTION (8.2.1.1)
COMPLETE UNIT TEST (8.3.4.4.1)
44
SOUND LEVEL TEST (8.3.4.5)
45
LATERAL ANALYSIS REQUIRED (9.1.3.4) (9.2.4.1.3)
NO
CLEANLINESS PRIOR TO FINAL ASSEMBLY (8.2.2.6)
46
MODAL ANALYSIS REQUIRED (9.3.9.2)
NO
LOCATION OF CLEANLINESS INSPECTION
47
DYNAMIC BALANCE ROTOR (6.9.4.4)
NO
NOZZLE LOAD TEST
48
INSTALLATION LIST IN PROPOSAL (10.2.3.l)
YES
CHECK FOR CO-PLANAR MOUNTING PAD SURFACES
49
VFD STEADY STATE DAMPED RESPONSE ANALYSIS (6.9.2.3)
MECHANICAL RUN TEST UNTIL OIL TEMP STABLE
50
4 HR. MECH RUN AFTER OIL TEMP STABLE (8.3.4.2.1)
51
TRANSIENT TORSIONAL RESPONSE
(6.9.2.4)
52
BEARING LIFE CALCULATIONS REQUIRED (6.10.1.6)
NO
IGNITION HAZARD ASSMT TO EN 13463-1 (7.2.13.e)
NO
NO
53
CASING RETIREMENT THICKNESS DRAWING (10.3.2.3)
54
FLANGES RQD IN PLACE OF SKT WELD UNIONS (7.5.2.8)
55
INCLUDE PLOTTED VIBRATION SPECTRA (6.9.3.3)
56
CONNECTION BOLTING (7.5.1.7)
57
CADMIUM PLATED BOLTS PROHIBITED
YES
58
VENDOR TO KEEP REPAIR AND HT RCDS (8.2.1.1.c)
YES
59
VENDOR SUBMIT TEST PROCEDURES (8.3.1.1)
YES
60
SUBMIT INSPECTION CHECK LIST (8.1.5)
YES
61
4 HR. MECH RUN TEST (8.3.4.2.2) BRG HSG RESONANCE TEST (8.3.4.7) STRUCTURAL RESONANCE TEST (9.3.9.2) REMOVE / INSPECT HYDRODYNAMIC BEARINGS AFTER TEST
YES
(9.2.7.5) AUXILIARY EQUIPMENT TEST (8.3.4.6) EQUIPMENT TO BE INCLUDED IN AUXILLIARY TESTS LOCATION OF AUXILIARY EQUIPENT TEST IMPACT TEST
(6.12.4.3)
PER EN 13445 PER ASME SECTION VIII
62 REMOVE CASING AFTER TEST
CLIENT: PROJECT:
PLUSPETROL PERU CORPORATION S.A PISCO DIESEL BLENDING Title: Page:
DATA SHEET FOR NON PRESSURIZED DRAIN PUMP PBB-3315 Code:
Perú Corp. S.A.
06 of 07
Revision:
PPIS-548-HD-M-013
0
API 610 CENTRIFUGAL PUMP DATA SHEET VERTICAL SUMP / CAN SPECIFICATIONS 1 Note VERTICAL TYPE (FIG 1.1) 2
Rev
VS4
REMARKS
3 4 5 VERTICAL PUMPS
6 7
VERTICAL PUMPS (CONT'D)
(+) UP
PUMP THRUST:
(-) DOWN
LINE SHAFT:
8
STATIC THRUST
lbf
lbf
LINE SHAFT DIAMETER
in.
9
AT MIN FLOW
lbf
lbf
TUBE DIAMETER
in.
10
AT RATED FLOW
lbf
lbf
11
AT MAX FLOW
lbf
lbf
12
MAX THRUST
lbf
lbf
13
SOLEPLATE REQUIRED
14
SOLEPLATE Length x Width
15
SOLEPLATE THICKNESS
16 17
ft
LINESHAFT CONNECTION
ft
X
in.
•
SUCTION STRAINER TYPE
•
LEVEL CONTROL
IMPELLER COLLETS ACCEPTABLE
MOUNTING FLANGE REQUIRED
HARDENED SLEEVES UNDER BEARINGS (9.3.10.5) RESONANCE TEST
COLUMN PIPE:
18
DIAMETER
in.
19
LENGTH
ft
20
NUMBER
21
SPACING
22
LINE SHAFT COUPLING:
STRUCTURAL ANALYSIS (9.3.5) DRIVER ALIGNMENT SCREWS
ft
SUCTION CAN SUCTION CAN
GUIDE BUSHINGS:
23
NUMBER
24
LINE SHAFT BEARING SPACING
THICKNESS
in. SEPARTATE MOUNTING PLATE (9.3.8.3.1)
26
PROVIDE SEPARATE SOLEPLATE (9.3.8.3.3)
27 BOWL HEAD CALCULATION REQUIRED
29
MATERIALS (additional)
30
SUCTION CAN / BARREL:
31
DISCHARGE HEAD :
32
BOWL SHAFT :
SHAFT ENCLOSING TUBE :
33
LINESHAFT :
DISCHARGE PIPE :
34
LINESHAFT HARDFACING :
PRESSURE RATING:
35
BELLMOUTH :
HEAD
36
BOWL BEARING :
CAST IRON
COLUMN PIPE
37
LINESHAFT BEARING :
CAST IRON
LINESHAFT SLEEVES :
BOWL
•
CARBON STEEL
38
BEARING RETAINER :
MAWP
SUMP / VESSEL ARRANGEMENT
39 SUMP DIMENSIONS :
40 41
SUMP DEPTH
L1
ft
42
SUMP STRUCTURAL COVER THICKNESS
L2
ft
43
FOUNDATION HEIGHT
L3
ft
44
GROUTING HEIGHT
L4
45
SUBMERGENCE REQUIRED
L5
46
SUMP TOP TO LOW LIQUID LEVEL
L6
47
GRADE TO 1ST STAGE IMPELLER
L7
By vendor
ft
48
PUMP LENGHT
L8
By vendor
ft
49
SUMP DIMENSIONS
ft By vendor
ft ft
ft
L9 X L10
50 51 52 53 VESSEL DIMENSIONS
54 55
VESSEL DIAMETER
M1
6
ft
56
BOOT DIMENSION (UNTIL TANGENT LINE)
M2
(NOTE 11)
ft
57
NOZZLE PROJECTION
M3
58
BOOT DIAMETER
M4
(NOTE 11)
ft
59
TOP OF DRUM TO LOW LIQUID LEVEL
M5
4.42
ft
60
NOZZLE TO 1ST STAGE IMPELLER
M6
By vendor
ft
61
SOLEPLATE NOZZLE DIMENSIONS
M7
2 (NOTE 4)
ft
62
PUMP SUBMERGENCE
M8
By vendor
ft
63
PUMP LENGTH
M9
By vendor
ft
66
in.
DRAIN PIPED TO SURFACE (9.3.13.5)
28
65
ft
DIAMETER
25
64
in.
LENGTH
2,5 (NOTE 4, 18) ft
HYDRO
CLIENT: PROJECT:
PLUSPETROL PERU CORPORATION S.A PISCO DIESEL BLENDING Title: Page:
DATA SHEET FOR NON PRESSURIZED DRAIN PUMP PBB-3315 Code:
Perú Corp. S.A.
PPIS-548-HD-M-013
07 of 07
Revision:
0
API-610 CENTRIFUGAL PUMP WELDING REQUIREMENTS AND NOTES PRESSURE VESSEL DESIGN CODE REFERENCES
1 Note 2
Rev
THESE REFERENCES MUST BE LISTED BY THE MANUFACTURER
3
CASTING FACTORS USED IN DESIGN ( TABLE 4)
4
SOURCE OF MATERIAL PROPERTIES
YES
5 WELDING AND REPAIRS
6 7
THESE REFERENCES MUST BE LISTED BY THE PURCHASER. (DEFAULT TO TABLE 11 IF NO PURCHASER PREFERENCE IS STATED)
8
ALTERNATE WELDING CODES AND STANDARDS
9
WELDING REQUIREMENT (APPLICABLE CODE OR STANDARD)
10
WELDER/OPERATOR QUALIFICATION
YES
11
WELDING PROCEDURE QUALIFICATION
YES
12
NON-PRESSURE RETAINING STRUCTURAL WELDING SUCH AS BASEPLATES OR SUPPORTS
13
MAGNETIC PARTICLE OR LIQUID PENETRANT EXAMINATION OF PLATE EDGES
YES (IF REQUIRED)
14
POSTWELD HEAT TREATMENT
YES (IF REQUIRED)
15
POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS
NO DEFAULT PER TABLE 11
16 MATERIAL INSPECTION
17 18
THESE REFERENCES MUST BE LISTED BY THE PURCHASER
19
ALTERNATIVE MATERIAL INSPECTIONS AND ACCEPTANCE CRITERIA (SEE TABLE 14) (8.2.2.5) TYPE OF INSPECTION METHOD
20
RADIOGRAPHY
21
ULTRASONIC INSPECTION
22
MAGNETIC PARTICLE INSPECTION
23
LIQUID PENETRANT INSPECTION
24 25 26 27
REMARKS : 1
28 29
CHARACTERISTICS OF THE HYDRAULIC CIRCUIT: Size Facing Rating DISCHARGE
1.5"
RF
150
30
2
FLUID VAPOR PRESSURE TO BE CONFIRMED BY PLUSPETROL.
31
3
VISCOSITY: 1.69 - 5.34 cP.
32
4
TO BE CONFIRMED BY VENDOR.
33
5
PUMP VENDOR SHALL INDICATE THE NUMBER OF MAXIMUM ALLOWABLE STARS PER UNIT OF TIME.
34
6
COOLING WATER IS NOT AVAILABLE.
35
7
HYDRAULIC CIRCUIT DESIGN CONDITIONS: DESIGN PRESSURE: 100 PSIG, DESIGN TEMPERATURE: 136 °F.
36
8
DISCHARGE PRESSURE AT GROUND LEVEL
37
9
PUMP WILL BE MOUNTED ON OPEN DRAIN VESSEL VBA-3315
38
10
DELETED
39
11
OPEN DRAIN VESSEL VBA-3315 IS UNDERGROUND AND DOES NOT HAVE A BOOT
40
12
NPSHA IS CALCULATED CONSIDERING PUMP SUCTION IS LOCATED 1 ft ABOVE VESSEL BOTTOM
41
13
PACKING ACCORDING DOCUMENT "PPIS-548-RI-M-003" PARAGRAPH 4.8.
42
14
INSPECTION AND TEST PLAN ACTIVITIES ACCORDING DOCUMENT "PPIS-548-RI-M-003" PARAGRAPH 7. PARTICULAR TECHNICAL REQUIREMENT, SEE DOCUMENT "PPIS-548-RI-M-003" PARAGRAPH 6.
43
15
44
16
MOTOR SHALL BE ACCORDING TO DOCUMENT PCSE-100-ET-E-001 "L.V ELECTRIC MOTORS".
45
17
MOTOR SHALL BE SUITABLE FOR END OF CURVE OPERATION.
46
18
DISTANCE FROM GRADE TO VESSEL TOP WALL: 2 ft.
47
19
FOR MORE DETAIL SEE P&ID DOC. PPIS-548-PL-Y-014-1.
48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65
DEFAULT TO TABLE 15 FOR FABRICATIONS
YES FOR CASTINGS