Nec Cable Tray Spreadsheet

  • Uploaded by: Xin Li
  • 0
  • 0
  • February 2021
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Nec Cable Tray Spreadsheet as PDF for free.

More details

  • Words: 567
  • Pages: 1
Loading documents preview...
Smaller than 4/0 AWG----120MM2 Size and Type C.S. Area (Sq.In.) 3.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Cable Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Diam. In 2.16

Smaller than 4/0 AWG----120MM2 Size and Type C.S. Area (Sq.In.) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Cable Number

Tray

Tray

Percent

Maximum

Sum

Allowed Cross

Actual Cross

No.

Size

Fill

Fill

Diameter

Area Fill

Area Fill

5 Tray

12 Tray

60% Percent

8.4 Maximum

2.2 Sum

8.4 Allowed Cross

3.7 Actual Cross

No.

Size

Fill

Fill

Diameter

Area Fill

Area Fill

Tray

18 Tray

60% Percent

12.6 Maximum

0.0 Sum

12.6 Allowed

3.7 Actual

No.

Size

Fill

Fill

Diameter

Wide Fill

Wide Fill

24

60%

14.4

0.0

14.4

3.7

Diam.

Cable Number

4/0 AWG----120MM2 & Above One Layer Size and Type C.S. Area (Sq.In.) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Available Designed By: Cross Area Space Checked By: Approved By: 4.7 KBR No. Available Designed By: Cross Area Space Checked By: Approved By: 8.9 Available

KBR No. Designed By:

(Column 1) Smaller than 4/0 AWG----120MM2

Client Job No.

KBR No.

Note: If value change in table current percent value need to be re-load

Doc. No.

Rev.

(Column 2) 4/0 AWG----120MM2 & Above together with Smaller than 4/0 AWG----120MM2 Client Job No.

Doc. No.

Client Job No.

4/0 AWG----120MM2 & Above One Layer Note: To leave half inch space between cables and to add "SPACE" Doc. No. legendRev. in Cable Number

Wide Space Checked By: Approved By: 10.7

Diam.

Rev.

CABLE TRAY FILL ALLOWED TO USE FOR:

NEC ARTICLE 392

FEED STAGE 1 STAGE 2 STAGE 3

60% 60% 70% 80%

Note: Values can be modified without affect formula results

Column 1 apply for conductors smaller than 4/0 Column 2 apply for conductors larger than 4/0 and smaller than 4/0 in same CT

NA 6 12 18 24 30 36 A

Col1 & Col2 NA 60% 70% NA NA 7 4.2 4.9 14 8.4 9.8 21 12.6 14.7 28 16.8 19.6 35 21 24.5 42 25.2 29.4 B

80% NA 5.6 11.2 16.8 22.4 28 33.6

NA NA 6 12 18 24 30 36

7 14 21 28 35 42

One Layer 60% 70% NA NA 3.6 4.2 7.2 8.4 10.8 12.6 14.4 16.8 18 21 21.6 25.2

80% NA 4.8 9.6 14.4 19.2 24 28.8

1.2 1.2 1.2 1.2 1.2 1.2 C

equals to B/C

1.17 equals to 1.2