Loading documents preview...
The SIMATIC S7 System Family SIMATIC PCS 7 SIMATIC NET
SIMATIC Software
SIMATIC PC
SIMATIC HMI
SIMATIC SIMATIC WinCC
SIMATIC DP SIMATIC Controller
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.1
Information and Training Center Knowledge for Automation
SIMATIC Overview SIMATIC PG SIMATIC PC
SIMATIC HMI
SIEMENS
S IM A T IC O P 17
PG 740
K1
K2
K3
K4
K5
K6
K7
K8
K9
K10
K 11
K12
K13
K 14
K15
K16
H E LP S H IF T
E S C
7
8 D
4
9 E
5 A
1
0 A C K
F
6 B
2
. C
3
S H IF T
IN S D E L
H E L P
E N T E R
MPI - Network Industrial Ethernet
SIMATIC NET SIMATIC NET
PROFIBUS
SIMATIC Controller SIEMENS
SF RUN STOP
I0 .0 I0 .1 I0 .2 I0 .3 I0 .4 I0 .5
Q0.0 Q0.1 Q0.2 Q0.3 Q0.4
CPU 212
Q0.5
I0 .6 I0 .7
SIMATIC S7-200
PROFIBUS-DP
SIMATIC DP
FM
ASI
SV
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.2
Information and Training Center Knowledge for Automation
S7-200
EM 221
SIEMENS
SF RUN STOP
I0.0 I0.1 I0.2 I0.3 I0.4
I1.0 I1.1 I1.2 I1.3 I1.4
I0.5 I0.6 I0.7
I1.5
Q0.0 Q0.1 Q0.2 Q0.3 Q0.4 Q0.5 Q0.6 Q0.7
Q1.0 Q1.1
CPU 214 I.1 I.2 I.3 I.4 I.5 I.6
SIMATIC S7-200
SIMATIC S7 Siemens AG 1999. All rights reserved.
DI 8 x DC24V I.0
I.7
Date: File:
04.09.2013 SYH_01E.3
Information and Training Center Knowledge for Automation
S7-200: Modules
CP242 - 2
EM
SIMATIC S7 Siemens AG 1999. All rights reserved.
EM
Date: File:
04.09.2013 SYH_01E.4
CP
Information and Training Center Knowledge for Automation
S7-200: CPU Design
Outputs
Memory Card
Mode Selector
Potentiometer SIEMENS
SF RUN STOP
I0 .0 I0 .1 I0 .2 I0 .3 I0 .4 I0 .5
Q0.0 Q0.1 Q0.2 Q0.3 Q0.4
CPU 212
Q0.5
I0 .6 I0 .7
SIMATIC S7-200
PPI Connection
Inputs
SIMATIC S7 Siemens AG 1999. All rights reserved.
Status Indicators
Status Indicators for integrated DI/DO
Date: File:
04.09.2013 SYH_01E.5
Information and Training Center Knowledge for Automation
S7-300
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.6
Information and Training Center Knowledge for Automation
S7-300: Modules
PS (optional)
CPU
SIMATIC S7 Siemens AG 1999. All rights reserved.
IM SM: (optional) DI
SM: DO
Date: File:
SM: AI
04.09.2013 SYH_01E.7
SM: AO
FM: - Couting - Positioning - Closed-loop control
CP: - Point-to-Point - PROFIBUS - Industrial Ethernet
Information and Training Center Knowledge for Automation
S7-300: CPU Design
SIEMENS
CPU314
SIEMENS
CPU315-2 DP
SF BATF DC5V FRCE RUN STOP
SF BATF DC5V FRCE RUN STOP
RUN-P
RUN-P
RUN
RUN
STOP
STOP
M RES
M RES
SIMATIC S7-300 Batterie
SIMATIC S7 Siemens AG 1999. All rights reserved.
SF DP BUSF
SIMATIC S7-300 Batterie
MPI
Date: File:
04.09.2013 SYH_01E.8
MPI
DP
Information and Training Center Knowledge for Automation
S7-400
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.9
Information and Training Center Knowledge for Automation
S7-400: Modules
PS
CPU
SIMATIC S7 Siemens AG 1999. All rights reserved.
SM: DI
SM: DO
SM: AI
SM: AO
Date: File:
CP
04.09.2013 SYH_01E.10
FM
SM
IM
Information and Training Center Knowledge for Automation
S7-400: CPU Design (Part 1)
DI 32xDC24V
CPU 414-2 X 2 3 4
X 2 3 4
421 - 1BL00 - 0AA0
414 - 2XG00 - 0AB0
INTF EXTF
INTF EXTF
FRCE CRST
FRCE CRST
RUN STOP
RUN STOP
Start-up Type Switch
CRST WRST RUN-P RUN
DP
INTF EXTF BUSF
CRST WRST RUN-P RUN
Mode Selector
STOP CMRES
STOP CMRES
X3
X1
e.g. CPU412-1
X1
EXT.-BATT.
EXT.-BATT.
5...15V DC
5...15V DC
e.g. CPU416-2DP
* for further CPUs please see catalog
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.11
Information and Training Center Knowledge for Automation
S7-400: CPU Design (Part 2)
DI 32xDC24V
CPU 414-2 X 2 3 4
X 2 3 4
421 - 1BL00 - 0AA0
414 - 2XG00 - 0AB0
Fault LEDs for general CPU faults
INTF EXTF
INTF EXTF
DP
FRCE CRST
FRCE CRST
RUN STOP
RUN STOP
CRST WRST
CRST WRST
RUN-P RUN
RUN-P RUN
STOP CMRES
STOP CMRES
Fault LEDs for integrated DP interface
INTF EXTF BUSF
DP interface
Slot for Memory Card
X3
MPI interface X1 EXT.-BATT.
5...15V DC
SIMATIC S7 Siemens AG 1999. All rights reserved.
X1 EXT.-BATT.
External battery supply
Date: File:
5...15V DC
04.09.2013 SYH_01E.12
Information and Training Center Knowledge for Automation
Programming Devices
PG760
PG740
PG720
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.13
Information and Training Center Knowledge for Automation
PG/PC Requirements for Installing STEP 7
Hardware/Software
Requirements
•
Processor
80 486 or higher, Pentium recommended
•
Hard Disk (free)
Min. 300 MB (for Windows, Swap File, STEP7, Projects)
•
RAM
>= 32 MB, 64 MB recommended
•
Interfaces
CP 5611 or MPI card or PC-Adapter Programming Adapter for Memory Card
•
Mouse
Yes
•
Operating System
Windows 95/98/NT
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.14
Information and Training Center Knowledge for Automation
Installing the STEP 7 Software
SIEMENS
or PG 740
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.15
Information and Training Center Knowledge for Automation
Result of Installation Double-click on Icon
Activate via Start menu
SIMATIC S7 Siemens AG 1999. All rights reserved.
Date: File:
04.09.2013 SYH_01E.16
Information and Training Center Knowledge for Automation