UPDATES ON CHAPTER 2 :  MINIMUM DESIGN LOADS          NATIONAL STRUCTURAL CODE  OF THE PHILIPPINES NSCP 2015, VOLUME 1

Ronaldo S. Ison, F.ASEP, PP 2002‐2004, FPICE Chancellor, College of Fellows

Significant Changes to Chapter 2  Minimum Design Loads 







Load combinations for are changed due to the  use of strength‐based wind loading based on  ASCE 7‐10 Additional live load designations for parking,  garage, and ramp live loading Basic wind speed are revised based on latest  studies For communication towers, ANSI TIA/EIA 222G  latest edition is fully referenced in the NSCP

Significant Changes to Chapter 2  Minimum Design Loads 







Near‐source factors are revised to consider distance  to source <2 km to be distinct and with higher values Revision of magnitude limits for Seismic Source Type  A Use of spectral acceleration based on ASCE/SEI 7‐10  is recognized as an alternative procedure for  determining earthquake forces Rest of the Sections in Chapter 2 are unchanged with  reference to NSCP 2010 6th Edition

Material Densities 

Loadings Dead Loads 

Loadings Live Loads 

Loadings Live Loads 

Loadings Live Loads 

Live Load  Reduction                                    

Live Load  Reduction                                    

Loadings Roof Loads 

Loadings Earthquake Loads  SCOPE ‐ Structures or portions thereof  shall be, as a  minimum, be designed and constructed to resist  the effects of seismic ground motion SEISMIC AND WIND DESIGN ‐ When the code prescribed produces greater  effects, the wind design shall govern, but  detailing requirements and limitations of Section  208 Earthquake Loads shall be followed.

Earthquake Loads Design Base Shear – Static Force Procedure 

Cv I V W RT

(208‐9)

The total design base shear need not exceed the  following: 2.5Ca I (208‐10) V W R

Earthquake Loads Design Base Shear – Static Force Procedure  The total design base shear shall not be less than  the following: (208‐11) V  0.11Ca I W In addition, for Seismic Zone 4, the total base shear  shall also not be less than the following: (208‐12) 0.8ZN v I V W R

Occupancy  Categories

Occupancy  Categories

Seismic Importance Factors 

NSCP 2015 and NSCP 2010

Soil Profile Types

NSCP 2015 and NSCP 2010

Seismic Source Types

NSCP 2015 

NSCP 2010 

Near Source Factors

NSCP 2015 

NSCP 2010 

Seismic Coefficients

NSCP 2015 

NSCP 2010 

Seismic Coefficients

NSCP 2015 

NSCP 2010 

Response Modification and  Overstrength Factors

Seismic Map  of the Philippines  The Philippines is divided  into two (2) Seismic Zones : Seismic Zone 2 (Z=0.2) Islands oF Palawan,  Tawi‐ Tawi and Sulu Seismic Zone 4 (Z=0.4) Rest of the Philippine  Islands

Fault Map  of the Philippines  Distribution of Active  Faults and Trenches  (PHIVOLCS)

Fault Map  of the Philippines  Active Faults in the  Cordillera  Administrative Region  (CAR)

Fault Map  of the Philippines  Active Faults and  Trenches in Region 1

Fault Map  of the Philippines  Active Faults and  Trenches in Region 2

Fault Map  of the Philippines 

Active Faults in Region 3

Fault Map  of the Philippines  Active Faults and  Trenches in Region 4A

Fault Map  of the Philippines 

Active Faults in Region 4B

Fault Map  of the Philippines  Active Faults and  Trenches in Region 5

Fault Map  of the Philippines  Active Faults and  Trenches in Region 6

Fault Map  of the Philippines  Active Faults and  Trenches in Region 7

Fault Map  of the Philippines  Active Faults and  Trenches in Region 8

Fault Map  of the Philippines  Active Faults and  Trenches in Region 9

Fault Map  of the Philippines  Active Faults and  Trenches in Region 10

Fault Map  of the Philippines  Active Faults and  Trenches in Region 11

Fault Map  of the Philippines  Active Faults and  Trenches in Region 12

Fault Map  of the Philippines  Active Faults and  Trenches in Region 13

Fault Map  of the Philippines 

Active Faults and Trenches  in Autonomous Region                    of Muslim Mindanao (ARMM)

Fault Map  of the Philippines  Active Faults in  National Capital  Region (NCR)

Earthquake Loads Design Base Shear – Static Force Procedure 

Cv I V W RT

(208‐9)

The total design base shear need not exceed the  following: 2.5Ca I (208‐10) V W R

Earthquake Loads Design Base Shear – Static Force Procedure  The total design base shear shall not be less than  the following: (208‐11) V  0.11Ca I W In addition, for Seismic Zone 4, the total base shear  shall also not be less than the following: (208‐12) 0.8ZN v I V W R

Earthquake Loads Building Period, T

T = Ct(hn)3/4 = 0.0853(30)3/4 = 1.093 sec

30 m

Ct = 0.0853 for steel SMRF

Ct = 0.0731 for concrete SMRF T = Ct(hn)3/4 = 0.0731(30)3/4 = 0.937 sec Ct = 0.0488 for other systems T = Ct(hn)3/4 = 0.0488(30)3/4 = 0.626 sec

6m

Ground

Earthquake Loads Sample Problem – Design Base Shear

Zone 4, Z = 0.4 Seismic Source Type = A Distance to seismic source = 10 km Soil Profile Type = Sc I = 1.0 R = 8.5 W = 7300 kN

25m

Given:

Earthquake Loads Sample Problem – Design Base Shear Determine the structure period T using Method A. For concrete moment –resisting frames, Ct is 0.0731 T = Ct(hn)3/4 = 0.0731(25)3/4 = 0.81 sec. Find near source factors Na and Nv from Tables    208‐9 and 208‐10 for Seismic Source Type A and  distance to seismic source of 10 km. Na = 1.0 Nv = 1.2

Earthquake Loads Sample Problem – Design Base Shear Determine seismic coefficients Ca and Cv from  Tables 208‐11 and 208‐12 for soil profile type Sc and Zone 4. Ca = 0.40 Na                 Cv = 0.56 Nv = 0.4x1.0            = 0.56x1.2     = 0.4                               = 0.672

Earthquake Loads Sample Problem – Design Base Shear The total design base shear in a given direction is: V  = CVI/RT x W (NSCP   208‐4) = 0.672(1.0)/(8.5x.81) x 7300 = 712 kN (GOVERNS) the total design base shear need not exceed the following: V = 2.5(CaI)/R x W               (NSCP  208‐5) = 2.5(0.40)1.0/8.5 x 7300 = 858 kN

Earthquake Loads Sample Problem – Design Base Shear the base shear shall not be less than the  following: V  = 0.11CaIW                              (NSCP  208‐6) = 0.11(0.40)(1.0)(7300) = 321 kN in Seismic Zone 4, the total design base shear shall also be not less than: V = 0.8NvI/R x W (NSCP 208‐7) = 0.8(0.40)(1.20)(1.0)/8.5 x 7300 = 330 kN

Earthquake Loads Vertical Distribution The total design base shear, V, shall be distributed at  different floor levels according to the following:  Fx = (V‐Ft) x wxhx wxhx where: V  : design base shear Ft :  .07TV, when period, T > 0.7 second,  else Ft = 0 wx :  mass at floor level hx :  height of floor from ground level

Earthquake Loads Dynamic Analysis – Response Spectrum

Load Combinations Buildings, towers and other vertical structures  and all portions thereof shall be designed to  resist the load combinations in NSCP Section  203. The critical effect can occur when one or more  of the contributing loads are not acting.

Load Definitions

  









D = dead load E = earthquake load  Em = estimated maximum earthquake force that  can be developed in the  structure  F = load due to fluids with well‐defined pressures and    maximum heights H = load due to lateral pressure of soil and water  in soil L = live load, except roof live load, including any permitted    live load reduction Lr = roof live load, including any permitted live load  reduction

Load Definitions    



L

= live load, except roof live load, including any  permitted live load reduction Lr = roof live load, including any permitted live load  reduction R = rain load on the undeflected roof T = self‐straining force and effects arising from  contraction or expansion resulting from  temperature change, shrinkage, moisture  change, creep in component materials,  movement due to differential  settlement, or combinations thereof W = load due to wind pressure

Load Combinations for  RC Design and Steel Design       

U  =  1.4 (D  +  F) U =  1.2 (D+ F+T ) + 1.6 (L+H) + 0.5(Lr or R)         U =  1.2 D + 1.6 (Lr or R) + (f1L or 0.50 W)           U =  1.2 D + 1.0 W + f1 L  +0.5 (Lr or R)              U =  1.2 D + 1.0 E+ f1 L                                            U  = 0.9 D + 1.0 W + 1.6 H                                  U =  0.9 D + 1.0 E + 1.6 H f1 =    1.0    for floors in places of public assembly,  for live loads in excess of 4.8 kPa,       and for garage live load =    0.5     for other live loads

Load Combination for Strength Design Application of the strength design load  combinations that involve the seismic load  E   for the moment resisting frame   Z = 0.4 Ca = 0.44 I = 1.0 ρ = 1.1 f1 = 0.5

Load Combination for Strength Design Beam A‐B and Column C‐D are elements of the special moment‐ resisting frame.  Structural analysis has provided the following  individual beam moments at A, and the column axial loads and  moments at C due to dead load, office building live load, and  lateral seismic forces. Dead Load D    Live Load L    Lateral Seismic Load Eh Beam Moment at A 135 kN‐m 65 kN‐m 165 kN‐m Column C‐D axial load   400 kN 180 kN 490 kN Column Moment at C      55 kN‐m 30 kN‐m 220 kN‐m PROBLEM : Find the strength design moment at beam end A  and strength design axial load and moment at column top C.

Load Combination for Strength Design

Strength design moment at beam end A. Determine earthquake load E: The earthquake load E consists of two components as  shown below in equation (208‐1).  Eh is due to  horizontal forces, and Ev is due to vertical forces. E = ρEh + Ev (Section 208‐1) The moment due to vertical earthquake forces is  calculated  Ev = 0.5CaID = 0.5(0.44)(1.0)(135) = 29.7 kN‐m

Load Combination for Strength Design The moment due to horizontal earthquake  forces is given as Eh = 165 kN‐m Therefore = ρEh + Ev = 1.1(165)+29.7 = 211 kN‐m

Load Combination for Strength Design

U  =  1.4 (D  +  F)  = 1.4D  U =  1.2 (D+ F+T ) + 1.6 (L+H) + 0.5(Lr or R)   = 1.2D + 1.6L        U =  1.2 D + 1.6 (Lr or R) + (f1L or 0.50 W)  = 1.2D + 0.5L          U =  1.2 D + 1.0 W + f1 L  +0.5 (Lr or R) = 1.2D +0.5L      U =  1.2 D + 1.0 E+ f1 L  = 1.2D + 1.0E + 0.5L  U  = 0.9 D + 1.0 W + 1.6 H   = 0.9D  U =  0.9 D + 1.0 E + 1.6 H = 0.9D +1.0E 

Load Combination for Strength Design

Apply earthquake load combinations The basic load combinations for strength design (or LRFD) are given in Section 203.3.1.  For this example, the applicable equations are:

1.2D + 1.0E + f1L (Section 203‐5) 0.9D  1.0E (Section 203‐6) Using Equation (203‐5) and Equation (203‐6), the strength design moment at A for combined dead, live, and seismic forces are determined.

MA = 1.2MD +1.0ME + f1ML = 1.2(135)+1.0(211)+0.5(65)  = 406 kN‐m

MA = 0.9MD 1.0ME = 0.9(135)1.0(211) = 333 kN‐m or –90 kN‐m Therefore, MA = 406 kN‐m or –90 kN‐m

Load Combination for Strength Design Apply earthquake load combinations,  continuation… MA = 0.9MD  1.0ME  = 0.9(135) 1.0(211)  = 333 kN‐m or –90 kN‐m MA = 1.2MD + 1.6ML = 1.2(135)+1.6(65)  = 266 kN‐m   Therefore, MA = 406 kN‐m or –90 kN‐m

Strength design axial load and moment at column  top C. Determine Earthquake load E: E = ρEh + Ev where

Ev = 0.5CaID = 0.22D for axial load

E = ρEh + Ev  = 1.1(490)+0.22(400) = 627 kN for moment

E = ρEh + Ev  = 1.1(220)+0.22(55) = 254 kN

Apply Earthquake Load combinations: 1.2D + 1.0E + f1L 0.9D  1.0E

(Section 203‐5) (Section 203‐6)

Design axial force Pc at point C is calculated as Pc = 1.2D + 1.0E + f1L  = 1.2(400)+1.0(627)+0.5(180)  = 1197 kN

Pc = 0.9D  1.0E = 0.9(400)  1.0(627) = 987 kN‐m or ‐267 kN Therefore, Pc = 1197 kN or –267 kN

Apply Earthquake Load combinations, continued 1.2D + 1.0E + f1L (Section 203‐5) 0.9D  1.0E (Section 203‐6) Design axial force Pc at point C is calculated as Pc = 0.9D  1.0E  = 0.9(400)  1.0(627)  = 987 kN‐m or ‐267 kN Therefore, Pc = 1197 kN or –267 kN

Design moment Mc at point C is calculated : Mc = 1.2D + 1.0E + f1L   = 1.2(55)+1.0(254)+0.5(30)  = 335 kN‐m Mc = 0.9D  1.0E = 0.9(55)  1.0(254)  = 304 kN‐m or ‐205 kN‐m Therefore, Mc = 335 kN‐m or –205 kN‐m 



Note that the column section capacity must be designed for the interaction of Pc = 1197 kN compression and Mc = 335 kN‐m (for dead, live and  earthquake), and the interaction of Pc = 267 kN tension and Mc = ‐205 kN‐m (for dead and earthquake).

Design moment Mc at point C is calculated , continued Note that the column section capacity must be  designed for the interaction of Pc = 1197 kN  compression and Mc = 335 kN‐m (for dead, live and  earthquake), and the interaction of Pc = 267 kN  tension and Mc = ‐205 kN‐m (for dead and  earthquake).

Significant Changes to Chapter 2  Minimum Design Loads 







Load combinations for are changed due to the  use of strength‐based wind loading based on  ASCE 7‐10 Additional live load designations for parking,  garage, and ramp live loading Basic wind speed are revised based on latest  studies For communication towers, ANSI TIA/EIA 222G  latest edition is fully referenced in the NSCP

Significant Changes to Chapter 2  Loads and Actions  







Near‐source factors are revised to consider distance  to source <2 km to be distinct and with higher values Revision of magnitude limits for Seismic Source Type  A Use of spectral acceleration based on ASCE/SEI 7‐10  is recognized as an alternative procedure for  determining earthquake forces Rest of the Sections in Chapter 2 are unchanged with  reference to NSCP 2010 6th Edition