Wiley, Cleanroom Technology Fundamentals Of Design Testing Operation (2001)

  • Uploaded by: Joao
  • 0
  • 0
  • January 2021
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Wiley, Cleanroom Technology Fundamentals Of Design Testing Operation (2001) as PDF for free.

More details

  • Words: 65,572
  • Pages: 324
Loading documents preview...
Cleanroom Technology

Cleanroom Technology Fundamentals of Design, Testing and Operation

W. Whyte University of Glasgow, UK

JOHN WILEY & SONS, LTD Chichester

New York

Weinheim

Brisbane

Singapore

Toronto

Copyright 02001 W. Whyte Published by John Wiley & Sons Ltd, Baffins Lane, Chichester, West Sussex PO19 lUD, England National 01243 779777 International (+44) 1243 779777 e-mail (for order and customer service enquiries): [email protected] Visit OUT Home Page on http://www.wiley.co.uk or

http:l/www.wiley.com All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, scanning or otherwise, except under the terms of the Copyright, Designs and Patents Act 1988 or under the terms of a licence issued by the Copyright Licensing Agency, 90 Tottenham Court Road, London, UK WlP 9HE, without the permission in writing of the author. Other Wley Editorial Oflces

John Wiley & Sons, Inc., 605 Third Avenue, New York, NY 10158-0012, USA WILEY-VCH Verlag GmbH, Pappelallee 3, D-69469 Weinheim, Germany Jacaranda Wiley Ltd, 33 Park Road, Milton, Queensland 4064, Australia John Wiley & Sons (Asia) Pte Ltd, 2 Clementi Loop #02-01, Jin Xing Distripark, Singapore 129809

John Wiley & Sons (Canada) Ltd, 22 Worcester Road, Rexdale, Ontario M9W 1L1, Canada

British Library Cataloguing in Publication Data A catalogue record for this book is available from the British Library ISBN 0 471 86842 6

Produced from computer files supplied by the author Printed and bound in Great Britain by Biddles Ltd, Guildford and King’s Lynn This book is printed on acid-free paper responsibly manufactured from sustainable forestry, in which at least two trees are planted for each one used for paper production.

Contents ..............................................................................................................

Preface Acknowledgements...........................................................................................

....................................................................................................

...

xiii

xiv

1 Introduction 1.1 What is a Cleanroom? .................................................................................. 1.2 The Need for Cleanrooms .............................................................................. 1.3 Types of Cleanrooms ................................................................................... 1.5 What is Cleanroom Technology? ................................................................

1 1 7

5

7

..........................................................................

2 The History of Cleanrooms 9 2.1 The Early Years ........................................................................................... 9 2.2 Ventilated Operating Rooms ..................................................................... 12 15 2.3 Early Industrial Cleanrooms ...................................................................... 2.4 Unidirectional Flow Cleanrooms ............................................................... 17

.........................................................

3 Cleanroom Classification Standards 21 3.1 The History ................................................................................................ 21 3.2 The Basis of Cleanroom Standards............................................................ 22 3.3 Federal Standard 209 ................................................................................. 24 3.3. I The earlier Federal Standards 209 (A to 0)..................................... 24 3.3.2 Federal Standard 209 E ..................................................................... 24 3.4 IS0 Standard 14644-1 ............................................................................... 26 30 3.5 Pharmaceutical Cleanroom Classification ................................................. 3.5. I European Union Guide to Good Manufacturing Practice ................ 30 3.5.2 Guideline on Sterile Drug Products Produced by Aseptic Processing ............................................................................. 33

...................................................................................

4 Information Sources 4.1 The International Confederation of Contamination Control Societies (ICCCS) ...................................................................................... 4.2 International Cleanroom Standards ........................................................... 4.2.1 I S 0 standards .................................................................................... 4.2.2 Federal Standard 209E...................................................................... 4,2.3 Pharmaceutical standards ................................................................. 4.3 Cleanroom Books ......................................................................................

37 37 38 38 41 41 43

vi

Cleanroom Technolopy

4.4 Recommended Practices and Guides of the Institute of Environmental Sciences and Technology (IEST) ............................................................... 4.4.I IEST Recommended Practices (RPs).... ......................................... 4.4.2 IEST Guides ............... ................................ 4.5 Cleanroom Journals and M zines ..................... 4.5. I Free distribution ...................................................... 4.5.2 Journals and magazines available on subscr 4.6 Sources of Pharmaceutical Cleanroom Documents ................................... 4.7 lnternational Cleanroom Forum................................................................. 5 The Design of Turbulently Ventilated and Ancillary Cleanrooms

43 44

50 51

........ 53

5.1 Turbulently Ventilated Cleanrooms........................................................... 5.1.1 Air supply .............................. 5.1.2 High eficiency air filters ...... 5.1.3 Air movement within a turbulently ventilated cleanroom... 5.I .4 Room pressurisation and air movement co 5.1.5 Construction materials andfinishes .................................................. 5.2 Ancillary Cleanrooms ................................................................................ 5.2.1 Clothing change area ........................................................................ 5.2.2 Materials transfer area ...................................................................... 5.3 Containment Rooms ..................................................................................

53

62 63 63 66 67

................

6 Design of Unidirectional Cleanrooms and Clean Air Devices 71 6.1 Unidirectional Cleanrooms ........................................................................ 71 ................... 73 6.I . 1 Verticalflow unidirectional cleanrooms ........ 74 6.1.2 Horizontal flow unidirectionalflow rooms ....................... 6. I .3 UnidirectionalJlow rooms used in semiconductor manufacturing ... 76 6.2 Clean Air Devices ...................................................................................... 81 6.2.I Unidirectional air devices .................................... 6.2.2 Isolators and minienviron ............................................. 83

..........................................

7 Construction Materials and Surface Finishes 7.1 General Requirements ................................................................................ 7.2 Conventional Building Techniques ........................................................... 7.3 Modular Construction ................................................................................ 7.3.I Studless wall systems ...................... ........................................... 7.3.2 Framed wall systems .............................. .......................

91 91 93 95 95 96

Cleanroom Technology

7.4 7.5 7.6 7.7

vii

Doors and Widows ..................................................................................... 98 Floors .......................................................................................................... 98 99 Ceilings ...................................................................................................... Outgassing and Electrostatic Properties .................................................. 100

..................................................................

8 High Efficiency Air Filtration 8.1 Air Filters Used in Cleanrooms ............................................................... 8.2 The Construction of High Efficiency Filters ........................................... 8.3 Particle Removal Mechanisms ................................................................. 8.4 Testing of High Efficiency Filters ........................................................... 8.4.1 Military Standard 282 ..................................................................... 8.4.2 Sodium Flame Test (Eurovent 4/4) .................................................. 8.4.3 Institute of Erwironmental Sciences (ZEST) Recommended Practice ‘Testing ULPA Filters! ...................................................... 8.4.4 European Standard (EN 1822) ........................................................ 8.5 Probe (Scan) Testing of High Efficiency Filters ..................................... 8.6 Filter Housings for High Efficiency Filters .............................................

........................................................

9 Cleanroom Testing and Monitoring 9.1 Principles of Cleanroom Testing ............................................................. 9.2 Cleanroom Tests ...................................................................................... 9.2.1 Air supply and extract quantities ..................................................... 9.2.2 Air movement control between areas .............................................. 9.2.3 Filter installation leak test............................................................... 9.2.4 Containment leak testing ................................................................. 9.2.5 Air movement control within the room ............................................ 9.2.6 Airborne particles and microbial concentrations............................ 9.2.7 Additional tests ................................................................................ 9.3 Testing in Relation to Room Type and Occupation State ....................... 9.4 Re-testing to Demonstrate Compliance ................................................... 9.5 Monitoring of Cleanrooms .................................................................

103 103 104 106 109 109 110 110 110 111 112

115 116 116 117 117 118 118 118 118 118 119 120 121

................. 123

10 Measurement of Air Quantities and Pressure Differences 10.1 Air Quantities ......................................................................................... 10.1.1 Measuring air quantities fiom within a cleanroom ....................... 10.1.2 Anemometers .................................................................................. 10.2 Differential Pressure Tests .....................................................................

123 124 125 127

...

Vlll

Cleanroom Technology

10.2.1 Apparatus for measuringpressure differences ...... 10.2.2 Methods of checking pressure differences.. ........... 11 Air Movement Control Between and Within Cleanrooms..................131 11.1 Cleanroom Containment Leak Testing .................................................. I3 1 11.1.1 Methods of checking inJltration .......... .............................. 11.2 Air Movement Control within a Cleanroom .......................................... 11.2.1 Air movement visualisation ........... ...................... .. 134 11.3 Recovery Test Method ............................................................................ 139

.............................................................

12 Filter Installation Leak Testing 12.1 The Use of Aerosol Test Challenges ..................................................... 12.2 Artificial Smoke and Particle Test Challenges ...................................... 12.2.I Cold-generated oils ............................... ............................. 12.2.2 Hot generated smokes ..... 12.2.3 Polystyrene latex spheres ... ............................ 12.3 Apparatus for Measuring Smo .......................... 12.3.1 Photometer................................. .......................................... 12.3.2 Single particle counters.. ........... ............................... 12.4 Methods of Testing Filters and Filter Housings .................................... 12.4.1 Scanning methods ................................................................... 12.4.2 TestingJilters in unidirectionalJow rooms .................. 12.4.3 Filter testing in conventionally ventilated room............. 12.4.4 Repair of leaks ........................................

.......................................................................

141 144 145

147 147 148 149 150

13 Airborne Particle Counts 153 153 13.1 Airborne Particle Counters .................................................................... 156 13.2 Continuous Monitoring Apparatus for Airborne Particles .................... 158 13.3 Particle Counting in Different Occupancy States .................................. 160 13.4 Measurement of Particle Concentrations (IS0 14644-1) ...................... 13.4.1 Sample locations and number ..................................... 13.4.2 Airborne sampling volume ......... 13.4.3 Acceptance criteria .................... 162 13.5 Worked Example of I S 0 14644-1 Test Method .................................... 13.5.1 Number of locations................... ........................... . 162 13.5.2 Minimum air sampling volume ...................................................... 163 13.5.3 Sampling results ......................................................... ....... 163

ix

Cleanroom Technolopy

....................................................................................

14 Microbial Counts 14.1 Microbial Sampling of the Air ............................................................... 14.1.I Impaction onto agar...................................................................... 14.2 Microbial Deposition onto Surfaces ...................................................... 14.2.I Settle plate sampling ...................................................................... 14.2.2 Calculation ofthe likely airborne contamination .......................... 14.3 Microbial Surface Sampling .................................................................. 14.3. I Contact surface sampling .............................................................. 14.3.2 Swabbing ....................................................................................... 14.4 Personnel sampling ................................................................................

167 167 i68 171 171 172 173 173 174 175

...............................

15 Operating a Cleanroom: Contamination Control 177 15.1 Step 1: Identification of Sources and Routes of Contamination ............ 178 178 15.1,I Sources of contamination .............................................................. 15.1.2 Airborne and contact routes of transfer ........................................ 179 180 I5.I .3 Construction of a risk diagram ...................................................... 182 15.2 Step 2: Assessment ofthe Importance of Hazards ................................ 185 15.3 Step 3: Identification of Methods to Control Hazards ........................... 15.4 Step 4: Sampling Methods to Monitor Hazards and Control Methods .. 186 15.5 Step 5 : Establishing a Monitoring Schedule with Alert and Action Levels ..................................................................................................... 189 15.6 Step 6: Verification and Reappraisal of the System .............................. 190 15.7 Step 7: Documentation ........................................................................... 190 8: Staff Training ............................................................................. 191 Step 15.8

............................................................................

16 Cleanroom Disciplines 16.1 People Allowed into Cleanrooms .......................................................... 16.2 Personal Items Not Allowed into the Cleanroom .................................. 16.3 Disciplines within the Cleanroom .......................................................... 16.3.I Air transfer .................................................................................... 16.3.2 Personnel behaviour ...................................................................... 16.3.3 Handling materials ........................................................................ 16.4 Maintenance and Service Personnel ......................................................

...................................................................

17 Entry and Exit of Personnel 17.1 Prior to Arriving at the Cleanroom ........................................................ 17.2 Changing into Cleanroom Garments .....................................................

193 193 196 196 196 198 206 206 209 210 210

X

Cleanroom Technolopy

17.2.1. Approaching the pre-change zone .. .......................................... ............................................................. 1 7.2.2 Pre-change zone ....... ........................... 1 7.2.3. Changing zone ......... 17.2.4 Cleanroom entrance zone .............................................................. 17.3 Exit Changing Procedures .....................................................................

..................................................

18 Materials, Equipment and Machinery 18.1 Choice of Materials ................................................................................ 18.2 Items Supplied from Outside Manufacturing Sources ........................... 18.3 Wrapping Materials ............................................................................... 18.4 Transfer of Materials and Small Pieces of Equipment through an Airlock ............................................................................................... 18.4.I Transfer area with a bench ................................... 18.4.2 Transfer area without a bench.. 18.5 Entry of Machinery ................................................................................ 18.6 Transfer of Materials through Hatches and Sterilisers ..........................

...............................................................................

211 213 217 220

223 223 225 226 228

233 235

19 Cleanroom Clothing 237 19.1 Sources and Routes of Inert Particle Dispersion ................................... 238 19.1,I Sources ofparticles and mechanisms of release ........................... 239 19.1.2 Routes of transfer ofparticles ............................. ..................... 242 243 19.2 Routes and Sources ofMicrobia1 Dispersion ........................................ 19.2.1 Sources ofmicro-organisms ............ .......................... 241 19.2.2 Routes of microbial dispersion .................................. 244 245 19.3 Types of Cleanroom Clothing................................................................ 245 19.3.1 Clothing designs ............................................................................ 19.3.2 Cleanroomfabrics ............................ ................................. 246 .......................... 249 19.3.3 Garment construction ................................... .............. 249 19.3.4 Choice ofgarments ................................................. 19.3.5 Comfort ................................ 19.4 Processing of Cleanroom Garments and Change Frequency ................. 252 19.4.1 Processing ................................................................. 19.4.2 Frequency of change........................ ............................... 255 19.5 The Effect of Laundering and Wear ...................................................... 256 256 19.6 Testing of Cleanroom Clothing ............................................................. 19.6.I Fabric tests ........................... ................................. 257 19.6.2 Dispersal of airborne bacter ......................... 257

Cleanroom Technology

XI

19.7 Static Dissipative Properties of Clothing ...............................................

261

20 Cleanroom Masks and Gloves ............................................................... 20.1 Cleanroom Masks .................................................................................. 20.1.I Dispersion from the mouth ............................................................ 20.1.2 Face mask;s ..................................................................................... 20.1.3 Powered exhaust headgear............................................................ 20.2 Cleanroom Gloves ................................................................................. 20.2.1 Hand contamination and gloves .................................................... 20.2.2 Glove manufacturingprocess ........................................................ 20.2.3 Types ofgloves ............................................................................... 20.2.4 Testing of Gloves ...........................................................................

263 263 263 266 268 269 269 270 270 272

............................................................................

21 Cleaning a Cleanroom 21.1 Why a Cleanroom Must be Cleaned ...................................................... 2 1.2 Cleaning Methods and the Physics of Cleaning Surfaces ...................... 21.2.1 Vacuuming..................................................................................... 21.2.2 Wet wiping ..................................................................................... 21.2.3 Tacky rollers .................................................................................. 21.3 Implements Used to Clean Cleanrooms ................................................. 21.3.2 Dry and wet vacuum systems ......................................................... 21.3.2 Moping systems.............................................................................. 21.3.3 Wipers............................................................................................ 21.3.4 Tacky rollers .................................................................................. 21.3.5 Floor scrubbing systems ................................................................ 21.4 Liquids Used in Cleaning Cleanrooms .................................................. 21.4.1 Cleaning liquids............................... .......................................... 21.4.2 Disinfectants .................................................................................. 21.5 How Should a Cleanroom be Cleaned? ................................................. 21.5.1 General points ............................................................................... 21.5.2 Cleaning methods with respect to area type.................................. 21.5.3 Cleaning methods .......................................................................... 21.6 Test Methods ..........................................................................................

275 275 276 277 278 278 279 279 280 283 285 286 286 286 288 290 290 291 293 295

Index ................................................................................................................

297

Preface The dirt and bacterial-free conditions provided by cleanrooms are essential for much of modern manufacturing industry. Without clean conditions, products get contaminated and either malfunction or become hazardous to people. In recent years there has been a considerable increase in the number of cleanrooms. They are now used for the manufacture of items used in computers, cars, aeroplanes, spacecraft, televisions, disc players and many other electronic and mechanical devices, as well as the manufacture of medicines, medical devices and convenience foods. This rapid increase in the use of cleanrooms has created a demand for good quality information about cleanrooms that is free from the ‘hype’ of sales and marketing jarg,on. Information is also required to teach production personnel about their working environment, and how to conduct themselves within the cleanroom to minimi se contamination. Cleanroom technology can be divided into three parts: design, testing and operation. Cleanrooms have to be first designed and constructed; they then have to be tested to ensure they achieve their design specification and continue to do so; finally they have to be operated in such a way as to minimise contamination. This book covers, in a holistic way, these three main facets of cleanroom technology. This book has been written using the principals generally accepted within cleanroom industries. However, I have found many areas where no sound advice exists and have had to develop guidance using my knowledge and experience. Because of this, I have tried wherever possible to give the scientific reasons for the contamination control measures suggested, so that the worth of my opinions may be judged. However, many of the principals are one man’s opinion, and this should be borne in mind. This book is intended for anyone involved with cleanrooms who wishes an overview of the hndamentals of cleanroom design, testing and operation. However, it is inevitable that with my teaching background I would wish to help those who instruct, or are about to instruct, the subject of ‘Cleanroom Technology’ either at college, or to their cleanroom personnel. I hope the information given in this book is helpful in achieving these requirements.

x iv

Cleanroom Technology

Acknowledgements During my many years of involvement with cleanrooms I have been fortunate to meet many of the people who pioneered and developed cleanroom technology. Many of them I now consider as friends. From these people I received information that assisted me during my career; it is from my career experience that this book has been written. It would be impossible to name all of these people, and they must forgive me if they see an idea that they know was theirs. I must confine myself to acknowledging the help of those people who directly contributed to this book. This contribution has been in the nature of: being a co-author of an article that I have used when writing this book; reading and commenting on a chapter; helping in producing photographs. These people are (in alphabetical order) Neil Bell, Chuck Bernt, Roger Diener, Gordon Farquharson, Gordon King, Lynn Morrison, Bob Peck, Martin Reeves, Hal Smith and Neil Stephenson. I should also like to acknowledge the support of the Scottish Society for Contamination Control. The photographs on the cover of this book are reproduced by permission of Aberdeen City Council, Library and Information Service, Pentagon Technology, Analog Devices and Evanite Fiber Corporation. The permission to use other photographs, tables and drawings used within the book is acknowledged at the end of each chapter. Isabelle Lawson produced most of the drawings in this book, and Barbara McLeod read and commented on the script.

Introduction 1.1 What is a Cleanroom? It is clear that a cleanroom is a room that is clean. However, a cleanroom now has a special meaning and it is defined in the International Organization for Standarization (ISO) standard 14644-1 as: A room in which the concentration of airborne particles is controlled, and which is constructed and used in a manner to minimise the introduction, generation, and retention ofparticles inside the room and in which other relevant parameters, e.g. temperature, humidity, and pressure, are controlled as necessary.

The first two thirds of the definition is, in essence, what a cleanroom is. It is a room that minimises the introduction, generation and retention of particles. This is achieved, firstly, by supplying itwith exceptionally large quantities of air that has been filtered with high efficiency filters. This air is used to (1) dilute and remove the particles and bacteria dispersed from personnel and machinery within the room and, (2) to pressurise the room and ensure that no dirty air flows into the cleanroom. Secondly, a cleanroom is built with materials that do not generate particles and can be easily cleaned. Finally, cleanroom personnel use clothing that envelops themand minimises their dispersion of particles and micro-organisms. These and other similar measures that minimise the introduction, generation and retention of contamination in a cleanroom are discussed in this book. Cleanrooms can also control the temperature, humidity, sound, lighting, and vibration. However, these parameters are not exclusive to cleanrooms, and are therefore not discussed in any detail in this book.

Technology

2

Figure 1.1

Cleanroom

A cleanroom with personnel wearing special cleanroom clothing.

1.2 The Need for Cleanrooms The cleanroom is a modern phenomenon. Although the roots of cleanroom design and management goback for more than 100 years and are rooted in the control of infection in hospitals, the need for a clean environment for industrial manufacturing is a requirement of modern society. Cleanrooms are needed because people, production machinery and the building structure generate contamination. As will be discussed later in this book, people and machinery produce millions of particles, and conventional building materials can easily break up. A cleanroom controls this dispersion and allows manufacturing to be carried out in a clean environment. The uses of cleanrooms are diverse; shown in Table 1.1 is a selection of products that are now being made in cleanrooms.

3

Introduction Table 1.1 Some cleanroom applications Industry Electronics Computers, Semiconductor Production

TV-tubes, screens flat of integrated circuits inused computer memory and control

Micromechanics Gyroscopes, miniature bearings, compactdisc players equipment photographic laser Lenses, Optics film, Biotechnology Antibiotic production, engineering genetic pharmaceuticals, Pharmacy Sterile disposables sterile Medical Devices Heart valves, cardiac by-pass systems Food Drink and Brewery production,

unsterilized food and drink

It may be seen in Table 1.1 that cleanroom applications can be broadly divided into two. In the top section of Table 1.1 are those industries where dust particles are a problem, and their presence, even in sub-micrometre size, may prevent a product fimctioning, or reduce its useful life.

particle

c

Figure 1.2 Contaminating particle on a semiconductor

4

Cleanroom Technology

A major user of cleanrooms is the semiconductor fabrication industry, where processors are produced for use in computers, cars and other machines. Figure 1.2 shows a photomicrograph of a semiconductor with a particle on it. Such particles can cause an electrical short and ruin the semiconductor. To minimise contamination problems, semiconductors are manufactured in cleanrooms with very high standards of cleanliness. The bottom section of Table 1.1 shows manufacturers who require the absence of micro-organisms, as their growth in a product (or in a hospital patient) could lead to human infection. The healthcare industry is a major user of cleanrooms, as micro-organisms or dirt must not be injected or infused into patients through their products. Hospital operating rooms also use cleanroom technology to minimise wound infection (Figure 1.3).

Figure 1.3 Unidirectional flow system in an operating room

Introduction

5

It may also be seen from Table 1.1 that many of the examples are recent innovations and this list will certainly be added to in the future, there being a considerable and expanding demandfor these type of rooms.

1.3 Types of Cleanrooms Cleanrooms have evolved into two major types and they are differentiated by their method of ventilation. These are turbulently ventilated and unidirectional flow cleanrooms. Turbulently ventilated cleanrooms are also known as ‘nonunidirectional’. Unidirectional flow cleanrooms were originally known as ‘laminar flow’ cleanrooms. The unidirectional type of cleanroom uses very much more air than the turbulently ventilated type, and gives superior cleanliness. The two major types of cleanroom are shown diagrammatically in Figures 1.4 and 1.5. Figure 1.4 shows a turbulently ventilated room receiving clean filtered air through air diffusers in the ceiling. This air mixes with the room air and removes airborne contamination through air extracts at the bottom of the walls.

Figure 1.4 Conventionally ventilated type of cleanroom

6

Technology

Cleanroom

The air changes are normally equal to, or greater than, 20 per hour, this being much greater than that used in ordinary rooms, such as in offices. In this style of cleanroom, the contamination generated by people and machinery is mixed and diluted with the supply air and then removed. h i g h e f f i c i e n c y filters .

)

.

+

.

)

.

+

l

A

Figure 1.5

Unidirectional flow type of cleanroom

Figure 1.5 shows the basic principles of a unidirectional flow room. High efficiency filters are installed across a whole ceiling (or wall in some systems) and these supply air. This air sweeps across the room in a unidirectional way at a speed of around 0.4 m / s (80 Wmin) and exits through the floor, thus removing the airborne contamination from the room. This system uses much more air than the turbulently ventilated cleanroom but, because of the directed air movement, it minimises the spread of contamination about the room and sweeps it out through the floor.

Clean air devices, such as unidirectional benches or isolators, are used in both turbulently and unidirectional ventilated cleanrooms. These machines will give a localised supply of filtered air and enhanced air conditions where required, e.g. at the area where the product is open to contamination.

1.5 What is Cleanroom Technology? As can be seen in Figure 1.6, cleanroom technology can be divided into three broad areas. These areas can also be seen to parallel the use of the technology as the cleanroom user moves from firstly deciding to purchase a room to finally operating it. CLEANROOMTECHNOLOGY

CLEANROOM DESIGN AND CONSTRUCTION

standards layout construction material/* servicesand - water gases setting cleanroom to work

CLEANROOM TESTING and MONITORING

CLEANROOM OPERATIONS

\

testing that the new room performs as designed

testing to ensure that the room continues to perform as designed

0

monitoring the room conditions entry of people, machines and materials cleanroom disciplines to avoid contaminating the product cleanroom garments including gloves, masks, etc. cleanroom cleaning and cleaning equipment

Figure 1.6 Various parts of cleanroom technology and their interconnections

8

Cleanroom Technology

Firstly, it is necessary to design and construct the room. To do this one must consider (1) the design standards that should be used, (2) what design layout and construction materials can be used, and (3) how services should be supplied to the cleanroom. Secondly, after the cleanroom has been installed and working, it must be tested to check that it conforms to the stipulated design. During the life of the cleanroom, the room must also be monitored to ensure that it continually achieves the standardsthat are required. Finally, it is necessary to operate the cleanroom correctly so that the manufactured products are not contaminated. This requires that the entry of people and materials, the garment selection, cleanroom disciplines and the cleaning of the room are allcorrectly carried out. These fundamental elements of Cleanroom Technology are covered in this book.

Acknowledgements Figure 1.1 is reproducedbypermission of Compugraphicsand Pearce. Figure 1.3 is reproduced by permission of Fishers Services.

M+W

The History of Cleanrooms 2.1 The Early Years It is clear that the first cleanrooms were in hospitals. Lord Lister’s contribution to history was his realisation that bacteria caused surgical wound infection. He thought that the elimination of bacteria from the operating room should prevent infection. This was the scientific basis for the first cleanrooms. In the 1860s, Lister dramatically reduced infection in his operating room at the Royal Infirmary, Glasgow by use of an antiseptic solution (carbolic acid) that killed bacteria. He used this on the instruments, the wound and thesurgeon’shands,andheattemptedtoprevent airborne infectionby spraying it into the air. Shown in Figure 2.1 is a photograph taken in 1889 of a group of surgeons from the Aberdeen Royal Infirmary in Scotland using Lister’s spray, which sprayed carbolic acid into the air of an operating room. This photograph is interesting from several points of view. Lister’s spray is of historical interest, although it probably did little to reduce airborne bacteria. Also to be seen is the surgeon Ogston, who is the third figure from the right. He wasthe discoverer ofthebacteria Staphylococcus aureus, animportant cause of wound sepsis, then and now. It is interesting to observe the accepted mode of dress at that time. Although this photograph is probably posed, operations at that time were carried out without the protection of sterile (or even clean) clothing. The surgeonwouldoftenoperatewearinganoldfrockcoatcontaminatedwith bloody pus and bacteria. He might wear an apron or gown, but this would be used to protect him from blood and not meant to protect the patient from his bacteria.

Cleanroom Technology

10

? L

Figure 2.1 A group of surgeons with the Lister steam spray.

A photograph taken in the Royal Infirmary, Edinburgh, Scotland in the 1890s (Figure .2.2) shows a number of aspects of surgery that will interest those working in modern cleanrooms. The gas lamp seen in the top lefthand side of the picture confirms the age of the photograph, as do many other aspects. The surgeons can be seen to be wearing gowns, but not gloves, hats or masks. In the background of the operating rooms is a gallery where the medical students would crowd in to see the operation without consideration of the bacteria they dispersed; the gallery is the reason that operating rooms are still called operating ‘theatres’ in many parts of the world. The floor is exposed wooden flooring, and the sinks, buckets and exposed pipes reflect a bygone age where little was known of contamination control.

Figure 2.2 An operating room in the late 1890s.

Lord Lister’s reduction of wound sepsis was by an antiseptic method, as he used a disinfectant to kill the bacteria on bandages, the hands of the surgeon and in the operating room environment. One of his former assistants, Sir William Macewan, who succeeded Lister as Professor of Surgery at the University of Glasgow, along with other surgeons in Germany and the USA, developed Lister’s techniques into the fieldof aseptic techniques. By aseptic means they sought not to kill bacteria that entered the wound, but to prevent them from getting there. Boiling of instruments and bandages was introduced and the surgeons and nurses ensured their hands were rigorously ‘scrubbed’ to remove bacteria. By the year 1900, surgical gloves, masks and gowns had been introduced. These could be steam sterilised before an operation, although at a lower temperature and pressure than used today. These methods were the basisof cleanroom techniques used today. Shown in Figure 2.3 is an operating room in the Royal Infirmary, Edinburgh, photographed around 1907. The contrast to thephotograph in Figure 2.2 is noticeable. Electricity has been installed, but of more interest is the fact that the surgeon can be seen to wear gloves and a facemask. The face-

12

Technology

Cleanroom

Figure 2.3 Operating room in 1907 showing aseptic precautions

mask is below his nose, as it was not till the end of the 1930s that it was appreciated that it should go over the nose. There is also a terrazzo-type floor and tiled walls to facilitate disinfection and cleaning.

2.2 Ventilated Operating Rooms Although the operating rooms of yesteryear had contamination control methods that were similar to modem cleanrooms, an important omission was positive ventilation with filtered air. Artificial ventilation was rarely used in hospitals in temperate climates until the 1940s, and where ventilation was used it was more for comfort than contamination control. It was only aRer the end of the Second World War (l 945) that ventilation in hospitals was clearly advocated for contamination control. The problems of airborne infection of people in crowded situations that occurred in wartime, e.g. submarines, air raid shelters and army barracks, were studied. Microbiological warfare required the airborne dispersion of micro-organisms and

this was also studied. The airborne bacterial sampler was invented, and the ventilation of rooms and aerodynamics of particles were all studied during the Second World War. By the early 1960s, most of the principles that dictate the performance of turbulently ventilated rooms were known. Also established was the fact that people were the source of airborne bacteria, these being dispersed on rafts of skin, and that open-weave cotton garments did little to prevent this dispersion; tightly woven fabrics were required. In 1960 Blowers and Crew attempted to obtain a downward ‘piston’ of air (unidirectional flow, although they did not call it that) from an air diffuser fitted over the entire ceiling in an operating room in Middlesborough in England. Unfortunately, because of the thermal air currents from people and the operating room lamp, as well as movement of people, the low air velocity was disrupted; this made it impossible to achieve good unidirectional airflow. This was the situation when Professor Sir JohnCharnley (with assistance from Howorth Air Conditioning) decided to improve the ventilation in his operating room at Wrightington Hospital near Manchester in England.

Figure 2.4

The Chamley-Howorth ‘greenhouse’

14

Technolopy

Cleanroom

Charnley was a pioneer of hip replacement surgery. He devised an operation to replace a diseased joint with an artificial plastic and metal one. His initial operations gave a sepsis rate in the region of 10%.This was a major problem, and so he initiated a number of preventative measures. Using the knowledge that existed at the time (1961), Howorth and he attempted to perfect the ‘piston effect’ of a downward flow of air. Instead of using the whole of the operating room ceiling (as Blowers and Crew had done) they restricted it to a small area and hence improved the downward flow of air. They used a 7ft x 7ft-area ‘greenhouse’ placed within the operating room. This is shown in Figure 2.4. Figure 2.5 shows the diagram Charnley published of the airflow in the system; it can be seen that reasonable downward unidirectional flow was achieved.

A r e a o f failure to achieve downward displacement Operating table

f L

Figure 2.5 Section through Charnley’s original system showing the airflow

Charnley and Howorth Air Conditioning increased the air supply volume and thenincorporateddesignimprovementsusingtheknowledgegained from the work on laminar (unidirectional) flow systems in the USA and elsewhere. He found that the improvements in his operating room, and in

History

15

the fabric and design of clothing substantially reduced airborne bacteria. These reductionswereparalleledwithreductionsin deep hip infection. These werereducedfromabout10%in 1959, when his operatingroom conditions were poor, to less than 1.0% by 1970 when all his improvements were complete. The Medical Research Council of the United Kingdomconfirmed in the 1980s that the use of unidirectional flow enclosures with occlusive clothing would reduce the joint sepsis to one quarter of that found in turbulently ventilated operating rooms.

2.3 Early Industrial Cleanrooms In engineering industries, similar advances were being made. The development of the first cleanrooms for industrial manufacturing started during the Second World War, this was mainly in an attempt to improve the quality and reliability of instrumentation used in guns,tanks and aircraft. It was realised that the cleanliness of the production environment had to be improved, or items such as bombsights would malfunction. However, it was assumed that cleanrooms were kept clean like people’s homes. Surfaces like stainless steel, which did not generate particles, were used and kept clean. It was not appreciated that the airborne dispersionof large quantities of particles by machines and people should be minimised by supplying large quantities of clean air. For example, the dominant idea in a pharmaceutical production room was that it had to be kept free of micro-organisms by the use of copious quantities of disinfectants. The walls were made suitable for this purpose often being tiled, and the floor would be a terrazzotype having a gully and drains to remove the disinfectant. Ventilation was very basic, there being few air changes per hour, and there was little in the way of air movement control within the room, or between the production area and outside areas. Personnel were dressed in cotton clothing similarto that used in the operating rooms of that era, and clothes changing areas, if they existed, were very basic. The use of nuclear fission, as well as the biological and chemical warfare research carried out during the 1939-1945 Second World War, were thedrivingforcesfortheproduction of HighEfficiencyParticulate Air (HEPA) filters necessary to contain the dangerous microbial or radioactive

16

Technolorn

Cleanroom

contaminants. Their availability allowed cleanrooms to be supplied with very clean air, and low levels of airborne contamination to be achieved. Rooms with large volumes of well-filtered air supplied by ceiling diffusers were built between 1955 and the early 1960s. In the early 1950s the Western Electric Company in Winston-Salem, NC, USA was having a major problem in manufacturing missile gyroscopes. About 99 out of 100 gyroscopes were being rejected, the problem being identified as dust. It was decided that a ‘dust fiee’ production room should be built and this was designed by the AC Corporation and completed in 1955. Figure 2.6 shows the room soon after production started.

Figure 2.6 Gyroscope production room at Western Electric

This may be the first production cleanroom built that recognised all of the basic requirements of a cleanroom. Personnel wore synthetic fabric clothing with a cap; they also had a locker room for changing clothes. Construction materials were chosen for ease of cleaning and to minimise the production of particles. Cracks and comers were minimised and the vinylcovered floors were coved onto the wall and the lighting was flushmounted to minimise dust accumulation. As can be seen in the back right-

hand side of the photograph, pass-through windows were used. The airconditioned supply was filtered through ‘absolute’ filters that were capable of removing 99.95% of 0.3 pm particles, and the room was positively pressurised.

2.4 Unidirectional Flow Cleanrooms

Figure 2.7

Willis Whitfield in his original laminar flow room

18

Cleanroom Technolopy

The watershed in the history of cleanrooms was the invention, in 1961, of the ‘unidirectional’ or ‘laminar flow’ concept of ventilation at the Sandia Laboratories, Albuquerque, New Mexico, USA. This was a team effort, but it is to Willis Whitfield that the main credit goes. Shown in Figure 2.7 is a photograph of him in his original room, The room was small, being 6 ft wide by 10 ft long by 7 ft high (1.8 m x 3 m x 2.1 m). Instead of the air being supplied by ceiling diffusers and moving about the room in a random way, it was supplied by a bank of HEPA filters. This ensured that air moved in a unidirectional way from the filters across the room and out through the floor grilles. Shown in Figure 2.8 is a cross-sectional drawing of the original unidirectional airflow room. It may be seen that anyone working at the bench in the room should not contaminate anything in front of them, as their contamination would be swept away. F l o u r e s c e n t li h t s

Blower

A b s o l u t e filters

Figure 2.8 A cross-section of the original unidirectional cleanroom

History

19

The invention at Sandia was publicised in Time magazine of April 13th 1962, and this article created a great deal of interest. The article was as follows:

‘Mr Clean Scientists at the Sandia Corp. in Albuquerque, where nuclear weapons are designed and assembled, have a passionfor cleanliness. They have to. As weapons components are made smaller and still smaller, the presence of a single particle of dust can make larger and still larger trouble. The strictest housekeeper in all Sandia is Texas-born Physicist Willis J. Whitfield, creator of the Whitjield Ultra-Clean Room. “I thought about dust particles,” he says with a slight drawl. “Where are these rascals generated? Where do they go? Once he answered his own questions Physicist WhitJeld decided that conventional industrial clean rooms are wrong in principle. The usual system in clean rooms, which are necessary for an everincreasing number of industrial operations, is to keep dust particles from being released. Smoking is forbidden; so are ordinary pencils, which give off graphite particles. People who work in the clean rooms are ‘packaged” in special boots, hoods and coveralls and are vacuum-cleaned before they enter. The rooms themselves are vacuumed continually. But despite all these precautions each cubic foot of their air still contains at least 1,000,000 dust particles that are .3 microns (.000012 in.) or larger in diameter. This is a vast improvement over ordinary air, but Whitjield was sure he could do better. Abandoning the idea of keeping dust particles from being generated, he decided to remove them as soon as they appear. The Whitjield Ultra-Clean Room looks like a small metal house trailer without wheels. Its floor is metal grating. It is lined with stainless steel, and along one wall the workbench faces a 4 3 by l o f t bank of “absolutefilters ’’ that remove all particles above .3 microns from a slow stream of air. Most clean rooms use their filters simply to clean up incoming air. WhitjieldS trick is to make the clean air from the filters keep the room clean. It flows at I mph (a very faint breeze) across the workbench and past the people working at it. Workmen can dress in ordinary clothes and smoke if they desire. Dandrufi tobacco smoke, pencil dust and any other particles generated are carried away by the clean air, whisked down through the grating floor, and discharged outdoors. Every six seconds the room gets a change of ultra-clean air. No particles get a chance to circulate, and as a result, Physicist Whitjield’s room is at least 1,000 times as clean as the cleanest of its competitor’. ”

20

Technology

Cleanroom

The concept of unidirectional flowcleanroom ventilation wasvery quickly adopted by a large variety of industries, as high quality cleanrooms were urgently required.

Acknowledgements Figure 2.1 is reproduced by permission of Aberdeen City Council, Library and Information Services. Figure 2.2 and Figures 2.3 are reproducedby permission of Lothian Health Services Archive, Edinburgh University Library. Figure 2.4 is reproduced by permission of Howorth Airtech Ltd. Figure 2.5 is reproduced by permission of British Journal of Surgery. The article ‘Mr Clean’ is reproduced by permission of Time Inc.

3 Cleanroom classification standards 3.1 The History It can be argued, with justification, that the first standard written for cleanrooms was publishedby the American Airforce on March 1961 and known as Technical Manual (T.O.) 00-25-203. This considered cleanroom design and airborne particle standards, as well as operating procedures such as: entry procedures; clothing; restriction of certain articles; cleaning of materials; procedures for cleaning theroom. However, the standard that had the most influence on the design and operation of cleanrooms, and is the basis of most world cleanroom standards, including I S 0 standard 14644-1, was Federal Standard 209. The Sandia Corporation team that invented the unidirectional concept, aided by others from the USA military, industry and governmental agencies, produced the first Federal Standard 209 in 1963. This standard discussed both conventional and unidirectionalcleanrooms. In thestandard there is the first suggestion of measuring particles of2 0.5pm by meansof optical particle counters; these instruments had just become commercially available. It often asked why 0.5 km was adopted as the standard size on which the Federal Standard wasbased. The answer is thatit was the ‘art of the achievable’, as this was the smallest size that was easily measured by the particle counters available at that time. It has been asked why 90 ft/min was suggested in the Federal Standard 209 as the velocity to be used in unidirectional flow cleanrooms. It has

22

Technology

Cleanroom

been said that this was the velocity theoretically calculated to remove a particle dropped in front of the supply filter in the first laminar flow room at Sandia Corporation. An alternative opinion given was that the only air supply fan available to Willis Whitfield gave this air velocity. I have discussed this with Willis Whitfield who said that the fan was capable of giving velocities of between50 ft/min and 200 ft/min. When the room was run at high velocities,it was very noisy and expensive maintain. to When run at 50 ft/min, and with only one person in it, it was possible to obtain good particle counts. However, if several people were in the room, a velocity of about 90 ft/min to 100 ft/min was required to control the particle contamination. As he and histeam were under pressure to produce data for the design of unidirectional cleanrooms, and little time was available for a thorough scientific evaluation,this velocity was adopted. Cleanroom standards have beenwritten to cater for the needs of the expanded cleanroom industry. These are discussed below.

3.2 The Basis of Cleanroom Standards It is best to start this section of the book by giving some indication of the size of particles usedin cleanroom standards. The unit of measurement is a micrometre, one micrometre (1 pm) being one millionth of a metre. Figure 3.1 shows a drawing comparingparticle sizes. A human hair, a size that can be readily appreciated, is approximately 70-100 pm in diameter. Another size that helps to put particle sizes into perspective is the size of particle that can be seen on a surface. This is approximately 50 pm in diameter, although this varies quite considerably depending on the acuteness of sight of the person, the colour of particle the and the colour of the background. Cleanrooms areclassified by the cleanliness of their air. The most easily understood classification of cleanrooms is the one used in the earlier versions (A to D) of Federal Standard 209 of the USA. This classification has been superseded by the last version of the Federal Standard (E) and now by the International Standard I S 0 14644-1. However, this old classification is still widely used. In the older Federal Standards (A to D), the number of particles equal to, and greater than, 0.5 pm were measured in one cubicfoot

Classification

23

of air and this count used to classify a room. The most recent Federal Standard209 (E version) accepted a metric nomenclature, but in 1999, I S 0 14644-1 was published. This standard has been adopted by all countries in the European Union and is now being adopted by other countries. In this book,cleanroom classifications aregivenaccording to IS0 14644-1, with the Federal Standard 209 classification given in parentheses, e.g. IS0 Class 5 (Class 1.00).

THICKNESS OF HUMANHAIR 100

mp

VISIBLE P A R T I C L E

50

4

mp

0.5 m p P A R T I C L E

Figure 3.1 Comparison of particle diameters

Technology

24

Cleanroom

3.3 Federal Standard 209 3.3.l The earlier Federal Standards 209 (A to D)

The first Federal Standard 209 was publishedin 1963 in the USA and titled “Cleanroom and Work Station Requirements, Controlled Environments”. It was revised in 1966 (209A), 1973 (B), 1987 (C), 1988 (D) and 1992 (E). The cleanroom class limits, given in the earlier 209 A to D versions, are shown in Table 3.1. The actual class of a cleanroom is found by measuring the number of particles 2 0.5 pm in one cubic foot of room air, and determining which class limit is not exceeded; this is the cleanroom classification. Table 3.1 Federal Standard 209 D class limits Class

Particles 2 0.1

pm

2 0.2

1

35

10 100

350 NA

1,000 10,OOO 100,000

NA

7.5 75 750 NA

NA NA

NA NA

pm

/ ft’ 2 0.3 pm

20.5 pm l

2 5.0

3 30

10

300 NA NA NA

100

NA NA

1,000

7

10,000 100,000

70

pm

NA

700

3.3.2 Federal Standard 209 E In Federal Standard209Ethe airborne concentrations in the room are given in metric units, i.e. per m3 and the classifications defined as the logarithm of the airborne concentration of particles 2 0.5 pm per m3. For example, a Class M3 room has a class limit for particles 2 0.5 pm of 1000/m3. The logarithm of 1000 is 3, which is the class. This is shown in Table 3.2. The current version is available from the Institute of Environmental Sciences and Technology in the USA. Their contact information is given in Chapter 4.

Table 3.2 Federal Standard 209 E class limits

Class Limits

>O.lpm

Class Name

2 0.2pm

2

0.3pm

2

0.5pm

2 5pm

Volume Volume Units Volume Units Volume Units Volume Units SI

0.875

30.9

1

(R3)

(m3)English

2.14 M75.7 1 9.91 350 1.5 M35.3 3.00 l 106 7.50 1240265 35.0 2.83 100 M 2 8.75 309 21.4 3 500757 99.1 2.5 M 10 75.0 650 124002 350 M 3 7 991 000 35 570 100 3.5 M __ ___ 140 __ 2 700 M4 4.5

M M5 M 5.5 __ M 6 100 M 6.5 M7

000 __

-- __ __

I O 000

--

__

__ 000

--

__

Units

(m3)

(ft3)

(m3)

(ft3)

(m3)

(ft3)

(m31

(ft3)

10.0

0.283

__ __ __ -_ --

--

1.oo

__ 10.0 353 30.01 060 87.5 214090 3 26 500 750 10600 75 30900

__ __17.5 _-

-_ 618 __

__ --

__ __

1000

300 1003 530 875 10000

-__ 300 830 __ --2 __000 __ -__ _- 175 -- 180 __ 6 -__ 350

__

__

--

__

35 100 353 000 1000000 300 3 000 10000000

28.3 283 __

--

__ __ __ __

__

1 000 7.00 247

10000 2470 28 100 000 700700 24 283800 000 61

70.0

1750

3.4 I S 0 Standard 14644-1 The International Organization for Standards (ISO) is developing a series of cleanroomstandards. These cover a widevariety of important cleanroom issues such as design, testing, operation and biocontamination. The first document, published in 1999, is I S 0 14644-1 and entitled ‘Classification of Air Cleanliness’. Thisgives the cleanroom classification method.Other standards are also available and these are discussed in the Chapter 4. Information on where to purchase the IS0 14644-1 standard is also given in the Chapter4. The I S 0 classification is based onthe following equation:

where: Cn is the maximum permitted concentration (in particles/m3 of air) of airborne particles that are equal to, or larger, than the considered particle size. Cn is rounded to the nearest whole number, using no more than three significant figures. N is the I S 0 classification number, which shall not exceed the value of 9. Intermediate I S 0 classification numbers may be specified, with 0.1 the smallest permitted incrementof N. D is the considered particle size in pm. 0.1 is a constant with a dimension of pm. From equation 3.1, the maximum permitted airborne concentration of particles, i.e. the class limit can be calculated for any given particle size. Shown in Table 3.3 are the classes selected by IS0 14644-1 to illustrate class limits. It should be noted that there is a crossover to the Federal Standard 209 classes. If the particle concentration/m3 in the I S 0 standard is divided by 35.2 the count is converted to counts/ft3 . The equivalent Federal Standard

Classification

27

209 classification is then found in Table 3.3 at the 0.5 pm size, e.g. an I S 0 Class 5 is equivalent to Federal Standard 209Class 100 or M3.5. Table 3.3 Selected IS0 14644-1 airborne particulate cleanliness classes for

cleanrooms and clean zones

~

IS0 Classification number

Maximum concentrationlimits (particledm’ of air) for particles equal to andlargerthantheconsidered sizes shown below 20.1pm

IS0 Class 1

10

2

I S 0 Class 2

100

24

10

IS0 Class 3

1 000

:!37 35

102

IS0 Class 4

10 000

2 370

1020

352

83

I S 0 Class S

100 000

23 700

10200

3 520

832

29

I S 0 Class 6

1 000 000

237000 102000

35 200

8 320

293

I S 0 Class 7

352 000

83 200

2 930

IS0 Class 8

3 520 000

832 000

29 300

I S 0 Class 9

3s 200 000

8 320 000

293 000

4 8

Table 3.4 Comparison between selected equivalent classes ofFS 209 and IS0 14644-1 I S 0 14644-1 Class

3

5

Class Class 4

Class6 Class

7

Class 8

Classes

FS Class 209 Class Class Class Class Class Classes

1

6 10

100

1000

10 000

100 000

Technolopy

28

Cleanroom

Given in I S 0 14644-1 is the same information in a graphical form. This is shown in Figure 3.2. It should be appreciated that the airborne particle concentration of a given cleanroom is dependent on the particle generating activities going onin the room. 10' 10'

10' IO' l0

10' 10 10'

lo1 lo'

0.1

0.2

0.3 0.5 l.o Particle size, D ,in p m

5 .O

Figure 3.2 Graphical representationof ISO-class concentration limitsfor selected I S 0 classes.

If a room is empty, a very low particle concentration can be achieved, this closely reflecting the quality of air supplied. If the room has production equipment in it that is operating, there should be a greater particle concentration, but the greatest concentration occurs when the room is in full production. The classificationof the room may therefore be carried out in these different occupancy states.

Classification

29

The occupancy states defined in IS0 14644-1 are as follows: As built: the condition where the installation is complete with all services connected and functioning, but with no production equipment, materials or personnel present. At-rest: The condition where the installation is complete with equipment installed and operating in a manner agreed between the customer and supplier, but with no personnelpresent. Operational: The condition where the installation is functioning in the specified manner,with the specified numberofpersonnel present and working in the manner agreed upon.

The I S 0 14644-1 standard also gives a method by which the standard of a cleanroom may be ascertained by measuring particles at various sampling locations. The method for determining the number of sampling locations, thesamplingvolumeandcountingthenumber of airborne particles is similar toFederal Standard 209 E and discussed in Chapter 13 of this book. IS0 14644-1 also includes a method for specifying a cleanroom using particles outside the size range given in Table 3.2. Smaller particles known in the standard as ‘ultrafine’ ( S 0.1 pm) are of particular importance in the semiconductor industry and the large ‘macroparticles’ (2 5 pm) are of use in industries, such as parts of the medical device industry, where small particles are of no practical importance. Fibres can also be specified. The M descriptor method employed withmacroparticles uses the format: “(a; b);c’ where a is the maximum permitted concentration/m3 b is the equivalent diameter. c is the specified measurement method. An example would be: “(1 000; 10 pm to 20 pm); cascade impactor followed by microscopicsizing and counting’. A similar classification method is used with ‘ultrafine’ particles.

TechnoloPy

30

Cleanroom

3.5 Pharmaceutical Cleanroom Classification Cleanrooms used for pharmaceutical manufacturing have their own standards. The two most widely used arethose published by the EuropeanUnion and the USA.

3.5.l European Union Guide to Good Manufacturing Practice The most recent pharmaceutical standard used in Europe came into operation on January 1997. This is called ‘The rules governing medicinal products intheEuropeanUnion.Volume 4. Good manufacturing practices Medicinal products for human and veterinary use’. It is often called the European Union Guide to Good Manufacturing Products (EU GGMP). This is available in various languages of the EU. Information as to where the standard can be obtained is given in Chapter 4. For the manufacture of sterile medicinal products four grades of airborne cleanliness are given. The airborne particulate classification forthese grades is given in Table3.4. Table 3.4

Airborne classification in the EU GGMP

Maximum permitted number of particles/m3equal to or above Grade

at rest (b)

in operation

0.5 pm

5 Pm

0.5 pm

5 Pm

A

3 500

0

3 500

0

B(a)

3 500

0

350 000

2 000

C(a)

350 000

2 000

3 500 000

20 000

W4

3 500 000

20 000

not defined (c)

not defined (c)

Classification Notes (a) In order to reach the B, C and D air grades, the number of air changes should be related to the size of the room and the equipment and personnel present in the as HEPA for room. The air system should be provided with appropriate filters such grades A, B and C. (b) The guidance given for the maximum permitted numberof particles in the ‘at rest’ condition corresponds approximately to the US Federal Standard 209 E and the IS0 classifications as follows: grades A and B correspond with class 100, M 3.5, IS0 5; grade C with class 10 000, M 5.5, IS0 7 and grade D with class 100 000, M 6.5, IS0 8. (c) The requirement and limit for this area will dependon the nature of the operations carried out. The particulate conditions given Table 3.4 for the ‘at rest’ state should be achieved after a short ‘clean up’ period of 15-20 minutes (guidance value), after the completionof operations. Examples of operations to be carried out in the various grades are given in the Table 3.5. The particulate conditions for a grade A zone that is in operation should be maintained in the zone immediately surrounding the product whenever the product or open container is exposed tothe environment. It is accepted that it may not always be possible to demonstrate conformity with particulate standards at the point of fill when filling is in progress, due to thegeneration of particles or droplets from the product itself. Table 3.5

Examples of cleanroom conditions required for different operations

GradeExamples

of Operations for Terminally Sterilised Products

A

Filling of products, when unusually at

C

Preparation of solutions,whenunusuallyat

D

Preparation of solutions

GradeExamples

risk risk. Filling of products

and componentsforsubsequentfilling

of Operations for Aseptic Preparations

A

Aseptic preparation filling and

C

Preparation of solutions be to filtered

D

Handling of components after washing.

Technology

32

Cleanroom

Microbiological monitoring is also required to demonstrate the microbiologicalcleanliness ofthecleanroomduring production. The recommended limits are givenin Table 3.6. Table 3.6 Recommended limits for microbial contamination Air Sample Grade

cfu/m3 (diam.

Settle Plates 90 mm), (diam. cfu/4 hours (b)

Contact Plates 55 mm),

Glove Print 5 fingers

cfu/plate cfu/glove

A

< l< l

B

10

5

5

C

100

50

25

D

200

100

50



Notes (a) These are average values. (b) Individual settle plates may be exposed for less than4 hours. (c) Appropriate alert and action limits should be set for the resultsof particulate and microbiological monitoring.If these limits are exceeded, operating procedures should prescribe corrective action. The air classification required for a cleanroom that has an isolator used to protect against contamination depends on the design of the isolator and its application. It should be controlled and for aseptic processing be at least grade D. Blow/fill/seal equipment used forasepticproduction, which isfitted with an effective grade A air shower, may be installed in at least a grade C environment, provided that grade A/B clothing is used. The environment should comply with the viable and non-viable limits ‘at rest’, and the viable limit only when in ‘operation’. Blow/fill/seal equipment used for the proinstalled in at leasta duction of products for terminal sterilisation should be grade D environment.

Classification Standards

3.5.2

33

Guideline on Sterile Drug Products Produced by Aseptic Processing.

This document is produced by the Food and Drug Administration(FDA) in the USA and published in 1987. Information on how to obtain this document can be foundin the Chapter 4. The FDA defines two areas in aseptic processing that are of particular importance to drug product quality. These are the ‘critical area’ and the ‘controlled area’. A ‘critical area’ is described in the FDA document as: ‘one in which the sterilized dosage form, containers, and closures are exposed to the environment. Activities that are conducted in this area include manipulations of these sterilized materials/product prior to and duringfilling/closing operations’.

The ‘controlled area’ is described as: ‘an area in which it is important to control the environment, is the area where unsterilized product, in-process materials, and container/closures are prepared. This includesareaswherecomponentsarecompounded,and where components, in-process materials, drug products and drug product contact surfaces of equipment,containers, and closures, after final rinse of such surfaces, are exposedto the plant environment’.

The environmental requirements for these two areas given in the Guide are as follows: 3.5.2.1 Critical areas The FDA guidelines give the following information: ilir in the immediate proximity of exposed sterilized containers/closures and filling/closing operations is of acceptable particulate quality when it has a per-cubic-foot particle count of no more than 100 in a size range of 0.5 micron and larger (Class 100) when measured not more than one foot away from the work site, and upstream of the air pow, during filling/closing operations. The agency recognizes that some powder filling operations may generate high levels of powder particulates which, by their nature, do not

34

Cleanroom Technology

pose a risk of product contamination. It may not, in these cases, be feasible to measure air quality within the one foot distance and still differentiate "background noise'' levels of powder particlesfrom air contaminants which can impeach product quality. In these instances, it is nonetheless important to sample the air in a manner, which to the extent possible characterises the true level of extrinsic particulate contamination to which the product is exposed. Air in critical areas should be supplied at the point of use as HEPA $1tered laminar flow air, having a velocity suficient to sweep particulate matter away from the$lling/closing area. Normally, a velocity of90 feet per minute, plus or minus 20%, is adequate, although higher velocities may be needed where the operations generate high levels ofparticulates or where equipment configuration disrupts laminarflow. Air should also be of a high microbial quality. An incidence of no more than one colony forming unit per I O cubic feet is considered as attainable and desirable. Critical areas should have a positive pressure dlfferential relative to adjacent less clean areas; a pressuredtfferential of 0.05 inch of water is acceptable'.

3.5.2.2 Controlled areas The FDA Guidelines give the following information: 'Air in controlled areas is generally of acceptable particulate quality if it has a per-cubic-foot particlecount of not more than 100,000 in a size range of 0.5 micron and larger (Class 100,000) when measured in the vicinity of the exposed articles during periods of activity. With regard to microbial quality, an incidence of no more than 25 colony forming units per 10 cubic feet is acceptable. In order to maintain air quality in controlled areas, it is important to achieve a suficient air jlow and a positive pressure differential relative to adjacent uncontrolled areas. In this regard, an airflow suficienf toachieve at least 20 air changes per hour and, in general, a pressure dtferential ofat least 0.05 inch of water (with all doors closed), are acceptable. When doors

Classification

35

are open, outward airflow should be suflcient to minimize ingress of contamination’.

Acknowledgements Table 3.3 and Figure 3.2, as well as extracts of I S 0 14644-1 are reproduced by permission of the British Standards Institution.

4 Information Sources It is important to be able to obtain current information about cleanrooms through the latest standards, books, recommended practices, magazines and other documents, as well as through the Internet. This chapter gives such information. This information was current when this book was published but communication details are continually changing. It is hoped that this chapter can be updated from time-to-time but readers should be aware of the possibility that the information may not be current.

4.1 The International Confederation of Contamination Control Societies (ICCCS) The ICCCS is a confederation of societies that have an interest in cleanroom technology. The present membership is as follows: ACCS: Australian Contamination Control Society, Australia ASCCA: Associazione per lo Studio ed il Controllo della Contaminazione Ambientale, Italy ASENMCO: Association of Engineers for Microcontamination Control, Russia ASPEC: Association pour la Prevention et 1’Etude de la Contamination, France BCW: Belgian Cleanroom Workclub, A.S.B.L., Belgium CCCS: Chinese Contamination Control Society, China GAA-RR of DINNDI: Gemeinschaftsarbeitsausschulj Reinraumtechnik, GAA-RR, within DIN and VDI, Germany ICs: Irish Cleanroom Society, Ireland

38

TechnoloPy

Cleanroom

IEST: Institute of Environmental Sciences and Technology, USA JACA: Japanese AirCleaning Association, Japan R3 Nordic: Renhetsteknik och Rena Rum, Denmark, Finland, Norway and Sweden KACRA: Republic of Korea, South Korea SBCC: Sociedade Brasileira de Controle de ContaminacAo, Brazil SEE: Society of Environmental Engineers, UK SRRT: Schweizerische Gesellschaft fur Reinraumtechnik, Switzerland S2C2: Scottish Society for Contamination Control, Scotland; VCCN: Vereniging Contamination Control Nederland, the Netherlands. Anyone who is interested in the design, testing or operation of cleanrooms is advised to join their local society to keep their cleanroom knowledge upto-date. A current list of the secretariates of member societies and their contact information is available on the ICCCS web site (www.icccs.orq) or through its Secretariate atthe following address: ICCCS Secretariate Postbus 311 3830 A J Leusden The Netherlands. Tel: +31 33 43 45 752 Fax: + 31 33 43 21 581 E-mail: icccs C3 tvvl.nl

4.2 International Cleanroom Standards 4.2.l I S 0 standards A rangeof cleanroom standards is being produced by the International Organization for Standardization (ISO). Various committees of experts, nominated by countries throughout the world, are writing these standards. The standards that have been published, or being written at the time of publication of this book, are as follows:

Information Sources

39

4.2.1.1 I S 0 14644 This consists of the following parts, under the general title ‘Cleanrooms and Associated Controlled Environments’: Part 1: Classification of air cleanliness This gives the airborne particle limits for different standards of cleanrooms. Italso gives the methods that should be used to measure the airborne particles when testing a cleanroom to determine its class. Part 2: Specl9cations -for testing and monitoring toprove continued compliance with ISO14644-1 This gives information, including time intervals, for testing a cleanroom to show that it still complies with the IS0 14644-1 standard. Part 3: Metrology andtest methods This gives a description of the test methods that should be used to test the cleanroom to show that it is working correctly. Part 4: Design, construction, and startup This gives general guidance as to how a cleanroom should be designed, constructed and made ready for handing over to the user. Part 5 Operation This gives general advice on how to run a cleanroom. Part 6: Terms and definitions This isa collection of all the definitions of terms used in the I S 0 cleanroom standards. Part 7: Separative enclosures (clean air hoods, gloveboxes, isolator, mini environments) This gives information on clean air devices such as isolators and minienvironments. Part 8: Molecular contamination This gives information on gaseous contamination in cleanrooms. 4.2.1.2 I S 0 14698 This consists of the following parts under the general title ‘Cleanrooms and Associated Controlled Environments-Biocontamination Control’:

40

Cleanroom Technolopy

Part I : General principles andmethods This gives information on how to establish methods for measuring microorganisms in the cleanroom. Part 2: Evaluation and interpretation of biocontamination data Thisgives information on how to deal with the results obtained from measuring micro-organisms in a cleanroom.

These standards are also available throughout the world from the various national standard organisations; they arealso available in some national languages. For further information on the various I S 0 members worldwide, where standards can be bought, you should visit the Internet at www.iso.ch/addre.html or contact: International Organization for Standardization (ISO) 1 rue de Varembe Case postale 56 CH- 1211 Geneve 20 Switzerland. Tel: +41 22 749 0111 Fax: +41 22 733 3430 Web site: www.iso.ch Information about the availability of these standards is available in the UK from the British Standards Institution using the following contact information: British Standards Institution Customer Services 389 Chiswick High Road London W4 4AL UK. Tel +44 (0)20 8996 9001 Fax +44(0)20 8996 7001 Web site: www.bsi-alobal.com

Information Sources In the USA thesestandardsareavailablefromthe Environmental SciencesandTechnology(IEST)usingthe communication details:

41

Institute of following

Institute of Environmental Sciences andTechnology 940 East Northwest Highway Mount Prospect Illinois, 60056, USA. Tel: +l 708 255 1561 Fax: +l 708 255 1699 Web site: www iest.org

4.2.2 Federal Standurd 209 E Although this standard is being superseded by I S 0 14644-1, it is still in use throughout theworld. It is available from IEST, their communication details being given immediately above (Section4.2.1.2).

4.2.3 Pharmaceutical standards The two mostcommonlyused standards concernedwithpharmaceutical cleanrooms are available from the European Union and the Federal Drug Association (FDA) in the USA. 4.2.3.1. The European Union Guide to Good Manufacturing Practice (EU GGMP) This can be downloaded free from the Internet at the following address: httr,://r,harmacos.eudra.org. It is contained in the‘units activities’ section under the heading ‘Eudralex’. Volume 4 is the correct document. This document is also available in various languages of the countries within the EU and obtained from bookshops in these countries. Information as to where these outlets areto be found can beobtained from:

42

Cleanroom Technology

Office for Official Publications of the European Communities 2 rue Mercier L-2985 Luxembourg. Tel+352 29 29-42455 Fax: +352 29 29-42758 Web site: http:lleur-otxeu.int Theaboveoffice encourages customers to purchase from their local distributors, contact information being published in the Internet site. In the UK, the EU GGMP is available from: Stationery Office PO Box 29 Norwich, NR3 1GN UK. Tel: +44 (0) 870 600 5522 Fax: +44 (0) 870 600 5533 Web site: www.the-stationery-office.co.uk 4.2.3.2 Guideline on Sterile Drug Products Produced by Aseptic Processing This can be downloaded free from the web site ofthe FDA Centre for Drug Evaluation and Research at: www.fda.gov. After opening the FDA site you should click on ‘Drugs’. The document is available, at the time of writing, in their ‘Regulatory Guidance’ section where it may be found in the ‘GuidanceDocumentsWebPage’ under the ‘Compliance’ heading. It is also possible (but not encouraged) toget it from the following address:

FDA Drug Information Branch HFD-2 10 5600 Fishers Lane Rockville MD 20857 USA. Tel: +l-301-827-4527 Web site: www.fda.gov

Information Sources

43

4.3 Cleanroom Books The following is a list of books (in alphabetical order) written in the English language that I know to be available through a bookstore. I would be pleased to receive any other titles so that the list can be extended. 1. Cleanroom Design edited by Whyte, W. (1991). Wiley, Chichester, UK. ISBN 0-471-92814-3. 2. Clean Room Design by Ljungvist, B.and Reinmuller, B. (1997). Interpharm Press, Buffalo Grove, IL 60089, USA. 3. Cleanrooms-Facilities and Practices by Kozicki, M. N. with Hoenig, S. A. and Robinson, P.A. (1991). Van Nostrand Reinhold, New York. ISBN 0-442-3 1950-9. 4. Contamination Control and Cleanrooms by Lieberman, A. (1 992). Van Nostrand Reinhold, New York. ISBN 0-442-00574-1. 5. Handbook of Contamination Control in Microelectronics Edited by Toliver, D. L. (1988). Noyes Publications, Park Ridge, NJ, USA. 6. Introduction to Contamination Control and Cleanroom Technology by Ramstorp, M. (2000). Wiley-VCH. ISBN 3-527-30142-9. 7. Isolator Technolou by Wagner, C. M. and Akers, J.E. (1995). Interpharm Press, Buffalo Grove, IL 60089, USA. 8. Isolator Technologv - a Practical Guide by Coles, T (1998). Interpharm Press, Buffalo Grove, IL 60089, USA. 9. Practical Cleanroom Design by Schneider, R K. (1995). Business News Publishing Company, Troy, MI, USA. ISBN 1-885863-03-9.

4.4 Recommended Practices and Guides of the Institute of Environmental Sciences and Technology (IEST) The IEST in the USA produce a large number of Recommended Practices (RPs) and Guides that cover many topics. They are an invaluable source of information and are available from:

44

Cleanroom Technology

Institute of Environmental Sciences and Technology 940 East Northwest Highway Mount Prospect Illinois, 60056, USA. Tel: +l 708 255 1561 Fax: +l 708 255 1699 Web site:

4.4. l IEST Recommended Practices (RPs) The following RPs are available: IEST-RP-CCOOI: HEPA and ULPAJilters Thiscoversthebasic provisions for HEPA and ULPA filter units. Six levels of performance and six grades of construction are included. IEST-RP-CCOOZ: Laminarflow clean-air devices Covers definitions, procedures for evaluating performance, and major requirements ofunidirectional flow clean air devices IEST-RP-CC003: Garments required in cleanrooms and controlled environments Provides guidance for the specification, testing, selection and maintenance of garments usein cleanrooms. IEST-RP-CCOO4: Evaluating wiping materials used in cleanrooms and other controlled environments Describes methods for testing wipers used in cleanrooms for characteristics related to cleanliness and function. IEST-RP-CCOOS: Cleanroom gloves andJinger cots Describes parameters and tests that apply to gloves and finger cots. IEST-RP-CC006: Testing cleanrooms Describes tests to evaluate and characterise the overall performance of the cleanroom and clean zone system. IEST-RP-CCO07: Testing ULPAJilters Describes a test procedure for production testing of ULPA filters for particle penetration and pressure drop.

Information Sources

45

IEST-RP-CCOO8: Gas-phase adsorbercells Covers the design and testing of modular gas-phase adsorber cells for use where high efficiency removal of gaseous contaminants is required. IEST-RD-CCOO9: Compendium of standards, practices, methods, and similar documents relating to contamination control Lists standards, practices, methods, technical orders, specifications, and similar documents developed by government, industry and technical societies in the United States and other countries. IEST-RD-CCOl1: A glossary of terms and deJnitions relating to contamination control Defines terms relating to contamination control and contains lists of frequently used abbreviations and acronyms. IEST-RP-CCO12: Considerations in cleanroom design Makes recommendations regarding factors to consider in the design of cleanroom facilities. IEST-RP-CCOI3: Equipmentcalibration or validation procedures Covers definitions and procedures for calibrating instruments used for testing clean rooms and intervals of calibration. IEST-RP-CCO1.5: Cleanroom production and support equipment Suggests approaches for the design, installation and operation of production and support equipment used within a cleanroom to minimise the contribution of that equipment to the contamination of the product. IEST-RP-CCO16: The rate of deposition of nonvolatile residue in cleanrooms Provides a method for determining the rate of deposition of nonvolatile residue (NVR) on surfaces in cleanrooms. IEST-RP-CCO18: Cleanroom housekeeping-operating and monitoring procedures Provides guidance for establishing housekeeping procedures and monitoring surface cleanliness. IEST-RP-CC020: Substrates and forms fordocumentation in cleanrooms Provides guidance for substrates and forms used in cleanrooms for the purpose of documentation.

46

Technolopy

Cleanroom

1EST-RP-CCO21: Testing HEPA and ULPAJilter media Discussestestmethodsfor physical and filtration properties of high efficiency particulate air andultra low penetration air filtration media. l EST-RP-CCO22: Electrostatic charge in cleanrooms and other controlled environments Discusses methods for specifying and evaluating the effectiveness of techniques for controllingelectrostatic charge. IEST-RP-CCO23: Microorganisms in cleanrooms Provides guidelines for the control and quantitative measurement of viable air and surfacecontamination. IEST-RP-CCO24: Measuring and reporting vibration in microelectronic facilities Discusses equipment used in the manufacture, measurement and inspection of integrated circuits sensitive to vibration and sound in the microelectronics industry. IEST-RP-CCO26: Cleanroom operations Provides guidance for maintaining the integrity of the cleanroom during preparation ofsupplies and materials, modification ofthe facility, and installation and repair of equipment. l EST-RP-CC02 7: Personnel practices and procedures in cleanroom and controlled environments Provides a basis for establishing personnel procedures and the development of training programs for cleanrooms. IEST-RP-CCO29: Automotive paint spray applications Providesrecommended procedures for controlling dirt in paint spray operations IEST-RD-CC031: Building code reference handbook: a guide to alternative code compliance issues in the semiconductor industry This document is a reference guide for code issues that require alternative compliance to design, construct or operation of semiconductor facilities. IEST-RP-CCO34: HEPA and ULPAJilter leak tests Covers definitions, equipment and procedures for leak testing filters in the factory and in the cleanroom.

Information Sources

47

4.4.2 IEST Guides The following Guides are available to complement IS0 14644-1 and IS0 14644-2: IEST-G-CC1 001: Counting airborne particles for classijkation and monitoring of cleanrooms and clean zones This guide provides information on methods used to sample air in clean environments using a discrete particle counter to determine concentrations of airborne particles. IEST-G-CClOO2: Determination of the concentration of airborne ultrafine particles. This supplements the coverage of procedures for determining the concentration of ultrafine particles as provided by I S 0 14644-1. IEST-G-CClOO3: Measurement of airborne macroparticles. This covers the sampling of macroparticles, these being the larger particles to be found in cleanrooms. IEST-G-CClOO4: Sequential-sampling plan foruse in classiJication of the particle cleanliness of air in cleanrooms and clean zones. This expands the coverage of sequential sampling as introduced in I S 0 14644-1.

4.5 Cleanroom Journals and Magazines 4.5.l Free distribution The following magazines are often distributed free of charge. However, this free circulation may be restricted to the country of publication, and to individuals that the magazine publishing companies consider to have bona fide cleanroom credentials. A2C2-Journal of Advancing Applications in Contamination Control This publication is published monthly by: A2C2 Vicon Publishing, Inc. 62 Route 101A

48

Technology

Cleanroom

Ste. 3 Amherst, NH 0303 1 USA. Telephone +l-603-672-9997 Fax: +l-603-672-3028 Web site: www.a2c2.com CleanRooms Cleanrooms ismonthly magazine produced by: CleanRooms 98 Spit Brook Road Fifth Floor Nashua NH 03062 USA. Tel: +l 603 891 0123 Fax: + l 603 891 9200 Web site: www.cleanrooms.com Cleanroom Technology This publication is publishedmonthly by: Polygon Media Ltd Tubshill House London Road Sevenoaks Kent, TN13 lBY, UK. Tel: +44 (0)1732 470000 Fax: +44 (0)1732 470047 Web site: www.cleanroom-technologv.eu.com Micro Magazine This publication is concernedwith defect reduction and yield enhancement strategies for semiconductor andadvance microelectronics and is published monthly by:

Information

49

Canon Communications 11444 W. Olympic Blvd Ste. 900 Los Angeles CA 90064 USA Telephone (for subscriptions)+l-651 686 7824 Fax (for subscriptions):+l-651 686 4883 Web site: www.micromagazine.com

4.5.2 Journals and magazines available on subscription. Journal of the Institute of Environmental Sciences and Technology This is available free tothe members of IEST, or by subscription. It covers a wider field of interest than cleanrooms, but usually has at least one article about cleanroom related issues in each issue. It is availablefrom: Institute of Environmental Sciences andTechnology 940 East Northwest Highway Mount Prospect Illinois, 60056 USA. Tel: +l 847 255 1561 Fax: +l 847 255 1699 Web site: www.iest.org European Journal of Parenteral Sciences This is a quarterly journal published by the Parenteral Society in the UK and is the official journal of the European Sterile Products Confederation (ESPC). It usually has articles concerned with contamination control in pharmaceutical manufacturing. Available from: European Journal of Parenteral Sciences Euromed CommunicationsLtd

50

Technology

Cleanroom

The Old Surgery Liphook Road, Hastlemere Surrey England, GU27 INL, UK Tel: +44-(0)1428 656665 Fax: +44 (0)1428 656643 Web site: www.euromed.uk.com/eivs PDA Journal of Parenteral Science The Parenteral Drug Association (PDA) in the USA publishes this journal. It usually has articles concerned with contamination control in pharmaceutical manufacturing. It is available from:

Parenteral Drug Association 7500 Old Georgetown Road Suite 620 Bethesda, MD 208 14 USA. Tel: + l 301 986 0293 Fax: + l 301 986 0296 Web site:www.vda.org

4.6 Sources of Pharmaceutical Cleanroom Documents Interpharm Catalog A catalogue of technical books, regulatory documents, productivity software and audio-visual training tools is available from: Interpharm Press 15 Inverness Way East Englewood CO 80 112-9240 USA.

Information Sources

51

Tel: + l 303 662 9101 Fax: + l 303 754 3953 Website: www.intemhann.com Parenteral Society This Society has a selectionof books, monographs and videos. They can be reached at: Parenteral Society 99 Ermin Street Stratton St Margaret Swindon

Wilts, SN3 4N1, UK. Tel: +44 (0)1793 824254 Fax: +44 (0) 1793 832551 Web site: www.varenteral.ora.uk Parenteral Drug Association. Thissocietyhasaselection monographs and videos. They can be reached at:

of books,

Parenteral Drug Association 7500 Old GeorgetownR.oad Suite 620 Bethesda, MD 20814, USA. Tel + l 301 986 0293 Fax+13019860296 Web site: www.pda.org

4.7 International Cleanroom Forum This is a questions and answer forum on the Internet. It is sponsored by the International Confederation of Contamination Control Societies (ICCCS) and maintained by the Scottish Society for Contamination Control (S2C2).

52 Expertsareavailable to answersimpleorcomplexquestionsabout cleanrooms. It can be accessed at eitherW. s2c2.co.uk or www.icccs.org.

The Design of Turbulently Ventilated and Ancillary Cleanrooms 5.1 Turbulently Ventilated Cleanrooms The ventilation principles of turbulently ventilated cleanrooms are similar to those found in most air conditioned rooms, such as offices and shops. The air is 5.1 supplied by an air conditioning plant through diffusers in the ceiling. Figure is a diagram of a simple turbulently ventilated cleanroom. This type of cleanroom is called a ‘turbulently ventilated’ cleanroom in this book as the air moves in a turbulent-random way within the room. This distinguishes it from a unidirectional flow cleanroom, where the air enters through filters across the whole ceiling, or wall, and flows in a unidirectional manner across the cleanroom. A turbulently ventilated room is also known as a ‘non unidirectional’ cleanroom; however, this does not describe the airflow well. as The design of a turbulently ventilated cleanroom differs from an ordinary air conditionedroom in a number ofways. These are:

0

The air supply volume is much greater. High efficiency air filters are used and normally fitted where the air enters the cleanroom.

54

Technology

Cleanroom

The air movement within the cleanroom assists in the removal of contamination. The room is pressurised so that air flows out to less-clean adjacent areas. Construction material and finishes are of a high standard. These attributes of a turbulently ventilated cleanroom are more detail.

m

now discussed in

Recirculated Air

Figure 5.1 A turbulently ventilated cleanroom

Turbulent and Ancillary Cleanrooms

55

5.1.l Air supply A normal air conditioned room, such as an office or shop, will be supplied with just sufficient air to achieve comfort conditions; this may be in the region of 2 - 10 air changes per hour. However, a typical turbulently ventilated cleanroom is likely to have between 10 and 100 air changes per hour. This additional air is required to dilute the contamination dispersed into the room and to reduce it to a concentration specified in a cleanroom standard. Cleanrooms require large quantities of air that is air conditioned and filtered to an very high standard. To ensure an economic design, it is essential that the cleanroom air is recirculated back through the air conditioning plant. However, it is also necessary to provide fresh outside air for the health of personnel working in the cleanroom and to pressurise the cleanroom against outside contamination. Normally between 2% and 10% of the total air supply is fresh air; large airtight rooms require a lower percentage than small less-airtight rooms. If air extract systems are used to removecontamination from around machinery or processes, then the percentage of fresh air will have to be increased to compensate. When designing a ventilation system for a room like an office, it is necessary to calculate the amount of air required to keep the room cool; this is dependent on the heat generated in the room. In cleanrooms it is quite common to find that production equipment produces large quantities of heat. It is therefore not unusual to find that the amount of air required to cool the room is similar to that required to achieve the correct clean air standard. Air changes per hour are a common way of expressing air dilution in the room and give an indication of the cleanliness of a room. However, the airborne cleanliness of a turbulently ventilated cleanroom is really dependent on the volume of air supplied to the room in a given time. The airborne cleanliness is also related to the generation of contamination from production machinery and personnel working in the room. If the air supply remains constant the cleanroom is dirtier if there are (a) more people in the cleanroom, (b) more activity from people, (c) cleanroom garments that are less effective in preventing

56

Cleanroom Technology

dispersion of contamination, and (d) more contamination coming from production machinery and processes. An approximation of the likely airborne cleanliness of a turbulently ventilated cleanroom can be found by use of the following equation: Airborne concentration (count/m3)

=

Number of particles (or bacteria) generated / min Air volume supplied * ( m3 / min)

* including that from unidirectional flow work stations and benches This equation cannot be used with a unidirectional flow system where the air flows in unidirectional streams, as the equation assumes that the room air is well mixed. It also assumes that the supply air is free from contamination; this is always true for the comparatively large microbe-carrying particles and true for most other particles; the exception is very small particles that can pass through the air filters. My investigations have shown that an average person moving about with poor cleanroom garments, such as smocks or laboratory coats, can generate about 2 x lo6 particles I> 0.5 p d m i n , about 300,000 particles 2 5.0 p d m i n , and about 160 microbe-carrying particles per minute. If people wear welldesigned clothing (coverall, knee length boots, hood, etc.) made from effective fabrics the average generation of particles per minute will be about IO6 for particles 2 0.5 pm, 150 000 for particles 2 5.0 pm and 16 for microbe-carrying particles. As discussed in Chapter 19, this will vary from person-to-person and from time-to-time. Little information is available about the generation of particles from machinery used in cleanrooms, but this can account for millions of particles 2 0.5 pm per minute. By using the above equation and airborne dispersion rates, it is possible to get an estimate of the likely airborne quality of a turbulently ventilated cleanroom. Unfortunately, because of the likely lack of reliable data about the particle dispersion from the machinery and processes, it may be difficult to get an accurate result. However, as people are normally the sole source of airborne bacteria, an estimate of the airborne bacterial count will be more accurate.

Turbulent

57

5.l .2 High efficiency air filters A cleanroom uses air filters that are much more efficient than those used in offices etc. Cleanroom filters would be normally be better than 99.97% efficient in removing particles greater than about 0.3 pm from the room’s air supply. These filters are known as High Efficiency Particle Air (HEPA) filters, although Ultra Low Penetration Air (ULPA) filters, which have an even higher efficiency, are used in microelectronic fabrication and similar areas. Most cleanrooms use HEPA or ULPA filters, but in the lowest standards of cleanrooms they are not essential. In an IS0 Class 8 (Class 100 000)room, bag-type filters, with an efficiency near to 90% against particles 2 0.5 pm, are often used. In most cleanrooms, HEPA or ULPA filters are installed at the point where the air is discharged into the room (see Figure 5.1). In air conditioning systems in offices and the like, the filters are placed directly after the air conditioning plant and the filtered air distributed by air ducts to the air supply diffusers. However, particles may be drawn into the air supply ducts, or come off duct surfaces and hence pass into the room. The filters in cleanrooms are therefore placed in a terminal position in the air supply duct. In lower standards of cleanroom, such as I S 0 Class 8 (Class 100 000), the particles that could enter, or come from, the ducts will be a smaller proportion of the total count; filters are often installed in the traditional position, just after the central air conditioning plant.

5. l.3 Air movement within a turbulently ventilated cleanroom The type, number and placement of air supply diffusers, as well as the extract grilles, is an important consideration in a turbulently ventilated cleanroom. It is possible to supply the air to a cleanroom with, or without, a diffuser. Air diffusers are used in many air conditioned rooms and situated where the supply air enters a room; they are designed to minimise the draught caused by high air velocities and ensure good air mixing. This is illustrated in Figure 5.2.

58

Cleanroom Technology

FILER

\ I .

lJ-

“‘L

Figure 5.2 Airflow conditions produced by a ceiling diffuser

In some conventionally ventilated cleanrooms, diffusers are not used and the supply air is ‘dumped’ down directly from the air filter into the cleanroom. This method is chosen to obtain unidirectional flow and good contamination control conditions under the filter; it is shown diagrammatically in Figure 5.3.

2 FILTER

Figure 5.3 Aifflow conditions produced by a ‘dump’ system

Turbulent

59

It is my opinion that the use of diffusers is best in conventionally ventilated cleanrooms. ‘Dump’ methods will give enhanced conditions below the supply area, but must therefore give poorer conditions elsewhere in the room. If enhanced conditions are required at critical areas, then it is better to ensure good air mixing in the cleanroom by means of diffusers, and use unidirectional cabinets or workstations at the critical areas. Diffusers should, however, be selected so that there are a sufficient number and size to give good mixing and draughtfree conditions. If the ‘dump’ method is chosen then the filters should preferably be distributed evenly about the room. There may be an advantage in grouping the filters together to protect an area that must be kept clean. However, if grouping is employed, it should be remembered that the standard of the cleanroom is determined by the dirtiest part and this may give a lower classification. Some further information on this topic is given in Section 6.1.3. It is normal practice in cleanrooms to site the air extract grilles at a low level around the walls; it is thought that high-level extracts cause a shortcircuiting of air from the air supply and hence the room is not swept by clean air. This will happen in a unidirectional flow, as the air moves in lines. However, in turbulently ventilated cleanrooms when diffusers are used, the air supply is quickly and thoroughly mixed with the rest of the room; this is the function of a diffuser. If diffusers are not used, the airflow from the filters is more unidirectional and short-circuiting to an extract is more likely to occur. Where the air extract is positioned is likely to be of little consequence if diffusers are used; in this situation any small advantage in using low level extracts is unlikely to be significant enough to require low level extracts if the design is more logical with high-level wall extracts.

5.I .4 Room pressurisation and air movement control between rooms A cleanroom must be designed to ensure that contaminated air does not come into the room from dirtier adjacent areas. Air should therefore always move from the cleanroom to less-clean adjacent areas. In Figure 5.1 the air will move

60

Technology

Cleanroom

out from the central production room to both the clothing change and materials transfer areas, and onwards to the outside corridor. To ensure that the movement is in the correct direction, airflow can be observed by smoke, water vapour or streamers; these methods are discussed in Section 11.2. However, although this method is satisfactory when setting up a cleanroom prior to hand-over, it is not a long-term monitoring possibility. To monitor a cleanroom, it is normal practice to check that the cleaner areas are more positively pressurised than less-clean adjacent areas. If a cleanroom is at ahigher pressure than an adjacent area then air will flow from the cleanroom to the adjacent area. Differential pressures of 10 Pa between two cleanrooms, and 15 Pa between a cleanroom and an unclassified area, are reasonable design pressures (12Pa = 0.05 inch water gauge). Where practical difficulties arise in achieving these pressures, e.g. where there is a supply tunnel connecting the two areas, a minimum pressure differential of 5 Pa may be acceptable. In a cleanroom suite, the air pressures should be set up so that the air moves from clean to the less-clean areas. This means that the highest pressure should be in the production area. Figure 5.4 is a diagram of a cleanroom suite that is slightly more complicated than Figure 5.1, as it has a two rooms in the clothing change area and hence another pressure differential to be maintained. In this suite the production room would be set at a pressure of 35 Pa compared to the outside approach corridor. This is necessary to give a 10 Pa pressure difference between the production room and the clothing change room, a 10 Pa difference between the change room and locker room and 15 Pa between the locker room and the outside approach corridor; this gives a total of 35 Pa. Because a 35 Pa pressure difference is established between the production room and the outside corridor, the same pressure is available across the material transfer room. The material transfer area can therefore be 15 Pa less than the production area and 20 Pa greater that the outside corridor; this pressure differential is greater than required but quite acceptable. However, if too large a pressure difference is used, extra energy costs will be incurred. Problems may

Turbulent and Ancillary Cleanrooms

61

also be experienced when trying to open and close doors, as well as ‘whistling’ through cracks. OUTSIDE CORRIDOR

+W

P r e s s u r ed a m p e or r g r l l l e Extract Atr supply

Figure 5.4

A simple cleanroom suiteshowing pressures and aifflow between areas

It must be decided what type of air movement control scheme between rooms in the cleanroom suite should be used. Two adjacent rooms, with their door closed can be set up with just sufficient air flowing through the gaps to give the correct, differential pressure between them. This is known as the ‘closed door’

62

Technology

Cleanroom

solution. However, the air flowing through the doorway may be quite small (especially if the door is a tight fit). The consequence of this is that when the door is opened little air is available to pass out through the doorway. There can then be an exchange of air across the open doorway caused by the air turbulence and an air temperature difference between the rooms. This may be acceptable and many cleanrooms are set up in this way. To minimise this unwanted air transfer it is normal to use an air lock, e.g. the materials transfer, or clothes changing areas. These air locks should be ventilated so that the contaminated air from the outside corridor, and any contaminants generated within the air lock canbe diluted. It may not be possible to provide an airlock between each cleanroom area, or it may be considered that theairborne contamination within an air lock is too high and should not be allowed to flow into the production area. It will then be necessary to provide an ‘open door’ solution, in which a system of cascading air passes through the open doorway in sufficient volume to prevent contaminated air entering. The design used toensure the correct airflow between rooms when the doors are open can be quite complicated. A solution to these problems is outwith the scope of this book. Readers who are interested in this topic should consult Chapter 4 of my book ‘Cleanroom Design’ published by John Wiley & Sons (1 999).

5.1.5 Construction materials andjhishes Another indication that a room is a cleanroom is its construction method. Cleanrooms should be constructed tominimise air leakage out of the room. The internal surface finishes should also be sufficiently tough to resist chipping or powdering when impacted, or abraded. The surface finish should alsobe smooth, easy-to-clean and not harbour dirt in cracks. Construction materials and surface finishes are discussed further in Chapter 7 of this book.

Turbulent and Ancillary Cleanrooms

63

5.2 Ancillary Cleanrooms Adjacent to the main production cleanroom there will be other cleanrooms. The number and type of these rooms will vary according to what is being produced within the cleanroom suite and the complexity of the task. In the simple cleanroom of the type shown in Figure 5.1, it can be seen that there is a room for personnel to change their clothing, and one to bring materials in and out of the production room. In other cleanrooms there may be additional rooms to produce materials required for the production room. These may also require additional clothing change materials transfer and storage areas.

5.2.1 Clothing change area Rooms used for changing into, and out of, cleanroom clothing vary in design. The number of rooms in the change area, and whether these rooms are divided into two or more zones by crossover benches, will vary. The design of the change areas may also be complicated if separate change rooms are provided for the two sexes. Sometimes lockers for outdoor clothing and valuables are provided outside the change area, and sometimes inside. Figure 5.5 is a diagram showing the plan view of a one-room change area which can be either one or twozones. In this type of room, personnel come into the room, take off their excess clothing and change into cleanroom garments and exit directly into the cleanroom; all of the change procedures are carried out in the one room. A pass-over bench is often provided to divide this room into two zones. This bench provides a seat for personnel to change or cover footwear; it also divides the room into two zones of cleanliness. A single room is popular in the more economically designed cleanroom. It is alsosuccessfully used in high quality cleanrooms with high numbers of staff, and often found in the microelectronics industry. Sometimes an airlock is additionally provided to minimise the transfer of contamination from the change area into the production area.

Cleanroom Technology

64

Figure 5.6 shows three possible designs of a two-room change area; these roomscanalsobefurther divided into zones by a pass-over bench. These rooms and zones can also be built in line. Change areas that have the greater number of rooms and zones give a more secure method of ensuring that the outside of the clothing is not contaminated, but more time hasto be devoted to changing. zones

r o o m with two

O nr oeowmiot hnz oe nOen e

Figure 5.5

One-room change areas

T w or o o m sw i t ht w oz o n e sT w or o o mw i t ht h r e ez o n e sT w o

r o o m w i t hf o u rz o n e s

change

pre-change

change

Pass-over bench

Figure 5.6 Two-room change areas with, or without, pass-over benches

Turbulent and Ancillary Cleanrooms

65

Procedures used to change in and out ofcleariroom clothing are discussedin how detail in Chapter 19; this should be consulted for an explanation as to these rooms areused. Consideration should also be given to where cleanroom garments should be stored if they are used again on re-entry. They should be stored so that contamination is minimised. In higher quality cleanrooms, clothing hangers are provided in a unidirectional flow ofair. An example of this methodis shown in Figure 5.7.

Fig=

5.7

Cleanroom clothing under a vertical unidirectional airflow

Other methods require the provision of lockers, pegs for clothing bags, or pigeon holes; further information is given in Section 17.3. Some change areas, especially those where cleanroom garments are changedat every entry, have a separate area for personnel to leave the cleanroom.

66

Cleanroom Technology

Airshowersaresometimes provided between thechange areas and the cleanroom. Personnel enter the air shower and turn around as air jets play on their cleanroom clothing. An air shower is designed to remove particles from clothing and hence reduce dispersion in a cleanroom. However, their use is controversial. I have studied the particle dispersion from people after showering as well as the particle count in the cleanroom, and it is my opinion that air showersdo little to reduce contamination in cleanrooms. However, they do have a psychologicaleffect of remindingpersonnel that they are entering a special area. This benefit, however, should be balanced against the production time lost while using, or waiting to getinto, the air shower. Cleanroom flooring and mats that remove dirt from shoes should be placed on the change areas floor. Where they are placed, and the type used, varies. More information is contained in Section 17.2.1.

5.2.2 Materials transfer area Figure 5.1 shows a typical airlock used as a materials transfer area. This allows materials to betransferred into the cleanroom with the minimum of contamination. More information as to how these are used is given in Chapter 18. An airlock may be divided into two zones by a crossover bench. However, a bench should not be provided if it is an obstacle to large equipment that is brought into the room. The materials transfer airlock will minimise the transfer of contamination from the outside corridor to the production room, and give a clean environment suitable for unwrapping the materials transferred into the production room. It shouldtherefore be ventilated. Air lock doors are often interlocked to ensure that both doors cannot be opened simultaneously. This minimises the direct exchange of air from the outside corridor to the production room. Airlocks can also have indicator lights fitted outside the doorsto show if anyone is in it. They ensure that when a person from the outside corridor enters the airlock, personnel from the cleanroom cannot also enter.

Turbulent and Ancillary Cleanrooms

67

5.3 Containment Rooms Cleanrooms are used to prevent the contamination of articles produced in the room. However, some manufacturing processes produce toxic chemicals or dangerous bacteria and these must be contained in a clean environment. This can occur, for example, in the pharmaceutical industry where highly active pharmaceuticals, such as hormones, must be kept clean but must not reach the operator. Other examples are found in the biotechnology industry where rooms are required to contain the genetically-engineered micro-organisms. Microbiological laboratories dealing with dangerous micro-organisms require that the personnel working in them, or the people passing near them, are not infected.

EXHAUSTA'R

l

h

Figure5.8

Containment room

The technology associated with the design of these containment rooms is similar to that used in cleanrooms, as containment rooms are often cleanrooms with containment facilities.

68

Technology

Cleanroom

Figure 5.8 is an example of a containment room that might be used for working with micro-organisms which are dangerous to the health of the personnel workingwithin it, or to anyonepassing close to theroom. It may be seen that clean air is supplied to the room, but more air must be extracted so that the roomwill be under a negative pressure and air will always flow into the room. The air that is extracted must be filtered through a high efficiency filter before being discharged to the outside environment. In Figure 5.8 this is donethrough the safety, or containment, cabinet.

n CLASS I

CLASS II

CLASS 111

Figure 5.9 Containment cabinets

Within the containment room shown in Figure 5.8 there is likely to be a safety cabinet.Shown in Figure 5.9 is a diagrammatic representation of the three types of safety cabinets that are available, showing their airflow and isolation principles. In a room where there is not a very high safety risk, a Class I or Class I1 cabinet is used. If clean conditions similar to the cleanroom are acceptable, a Class I cabinet may be chosen, as this isolates contamination in it by drawing air from the room. However, if cleaner conditions than the room are

Turbulent and Ancillary Cleanrooms

69

required then a Class 11 cabinet is used; this type gives a flow of filtered air over the product, while still ensuring a flow of air into the cabinet. In a highrisk area, a Class 111 cabinet would be used. A Class 111 cabinet is very similar, if not identical, to some designs of negative-pressure isolators and an overlap in design occurs here. Negative-pressure isolators can therefore be used in such applications. Another feature that may be found in containment rooms is an air lock to allow people to change into special clothing and to minimise airflow out of the containment room. A pass-through autoclave may be available to allow the sterilisation of contaminated material. Other containment rooms may be of a higher or lower standard, depending on the toxic, chemical or microbiological hazard of the room. Less hazardous rooms would not use an airlock or pass-through autoclave and rely on the exhaust of a Class I cabinet to create a negative pressure in the room. Rooms in which the hazard was high would use a Class 111 type of cabinet or a negative pressure isolator, and may provide a shower area between the air lock and the room. In particularly hazardous situations, personnel would wear suits supplied with filtered air. Chapter 6 of my book ‘Cleanroom Design’ is devoted to the design of containment facilities.

Acknowledgement Figure 5.7 is reproduced by permission of Roger Diener of Analog Devices.

Design of Unidirectional Cleanrooms and Clean Air Devices Cleanrooms that are ventilated in the turbulent manner described in the previous chapter may achieve conditions as low as I S 0 Class 6 (Class 1000) during manufacturing, but this is more likely to be I S 0 Class 7 (Class 10 000). To obtain rooms better than I S 0 Class 6 (Class 1000) during operation, greater dilution of the generated particles is required. This can be achieved by a unidirectional flow of air.

6.1 Unidirectional Cleanrooms Unidirectional airflow is used in cleanrooms when low airborne concentrations of particles or micro-organisms is required. This type of cleanroom was previously known as ‘laminar flow’, both names describing the flow of air. The airflow is in one direction, either horizontal or vertical, at a uniform speed that is normally between 0.3 and 0.5 m / s (60 ft/min to 100 ft/min) and throughout the entire air space. Figure 6.1 is a cross-section through a typical vertical flow type of cleanroom. It may be seen that air is supplied from a complete bank of hig,h efficiency filters in the roof of the cleanroom. The air then flows down through the room like an air piston, thus removing the contamination. It then exits through the floor, mixes with some fresh air brought in from outside, and recirculates back to the high efficiency air filters.

72

Technolopy

Cleanroom

Figure 6.1 Vertical unidirectional flow cleanroom

Airborne contamination from people and processes can be immediately removed by this flow of air, whereas the turbulently ventilated system relies on mixing and dilution. In an empty room with no obstructions to the unidirectional airflow, contamination can be quickly removed by air velocities much lower than those mentioned above. However, inan operating room there are machines causing obstructions to the airflow, and people moving about it. Obstructions may cause the unidirectional flow to be turned into turbulent flow and local air recirculation to be established round the obstructions. Movement of people will also turn the unidirectional flow into turbulent flow. With lower air velocities and air dilution, higher concentration of contamination can be established in these turbulent areas. A velocity in the region of 0.3 m/s to 0.5 m / s (60 ft/min to 100 ft/min) is necessary so that disrupted unidirectional flow can be quickly reinstated and the contamination in turbulent areas round obstructions adequately diluted. I have studied the effect of velocity in a variable-velocity unidirectional flow room that was operational. The velocity could be varied from 0.1 m / s to 0.6 m / s (20 ft/min to 120 ft/min). The results showed that a velocity of 0.3 m/s (60 ft/min) was required to give stable unidirectional flow and low particle and bacterial concentrations. Increasing the air velocity, in stages up to 0.6 m/s (120 ft/min) gave lower airborne counts, but this worked on the

Devices Air Unidirectional Clean Cleanrooms and

73

‘law of diminished returns’. The information obtained can be interpreted as suggesting that a velocity of 0.3 m / s (60 fdmin) gives the best returns for effort, but if a cleanroam has a high density of machinery, or personnel, a higher velocity would give lower airborne contamination. Unidirectional airflow is correctly defined in terms of air velocity as the higher the velocity the cleaner the room. Air changes per hour are related to the volume of the room, e.g. ceiling height and are therefore incorrect units of measurement. The air supplied to unidirectional flow rooms is many times greater (1 0s or 100s of times) than that supplied to a turbulently ventilated room. These cleanrooms are therefore very much more expensive to build and run. Unidirectional flow rooms are of two general types, namely horizontal or vertical flow. In the horizontal system, the airflow is from wall to wall and in the vertical system it is from ceiling to floor. 6.l .l VerticalJlow unidirectional cleanrooms

A vertical flow unidirectional cleanroom is shown in Figure 6.1. This shows the air flowing through the complete area of a floor. However, unidirectional flow rooms are also designed so that air is returned through extract grilles distributed around the wall at floor level. This type is illustrated in Figure 6.2. This design can only be used in rooms that are not too wide, and 6 metres (20 ft)has been suggested as a maximum width.

Exhaust

Exhaust

Figure 6.2 Vertical unidirectional cleanroom with exhausts in the wall

74

Technolovy

Cleanroom

Care must be taken with this design. The route that the supply air takes to get to the air exhausts is the reason for the problem. Airflow of the type shown in Figure 6.2 gives poor unidirectional flow in the centre of the room and a flow of air that is not vertical in the rest. Personnel may therefore contaminate the product if they are positioned between the air supply and the product.

6.I .2 Horizontal flow unidirectionalflow rooms Figure 6.3 shows a typical design of a horizontal flow cleanroom. In this design, the air is suppliedthrough a wall of high efficiency filters and flows across the room and exits on the other side. The air is then returned to a ventilation plant and back through the air filters. The area of a wall in most rooms is usually much smaller than the ceiling, and hence a crossflow room will cost less in capital and running costs than a downflow one. The horizontal flow type of cleanroom is not as popular as the vertical type. The reason for this is illustrated in Figure 6.4, which shows the problem that can occur with a contamination source.

SUPPLY PLENUM

RECIRCULATING LIGHTING

HEPA FILTER AIR EXHAUSTGRILLE

Figure 6.3 Horizontal unidirectional flow cleanrooms

Devices Unidirectional AirClean Cleanrooms and

Figure 6.4

75

Dispersion in both a downflow and crossflow cleanroom

Any contamination generated close to the filters in a vertical flow will be sweptacrosstheroomand could contaminate work that is progressing downwind. Generally speaking, a vertical flow of air gives better contamination control (as shown in Figure 6.4) because the dispersed contamination is less likely to reach theproduct. If the crossflow cleanroom can be arranged so that the most critical operations are close to the supply filters and the dirtier ones at the exhaust end, then this typeof room can be successful. The following works well:

Technology

76

Cleanroom

1. A faulty component, requiring repair, enters the end of the room away from the filters. 2. The component is dismantled in stages as work progresses towards the filters. 3 . The most susceptible-to-contamination repair is carried out next to the supply filters. 4. The component is reassembled and then packaged on its way back up the other sideof the cleanroom. 5. The repaired component exits outof the room, on the opposite side from the entering components. A crossflow type of cleanroom can also be successful if the machineproor cess is placed close to the filter bank and no-one passes between the filter bank and machinewhen production is going on. 6.1.3 Unidirectionalflow rooms used in semiconductor manufacturing

Unidirectional flow cleanrooms are muchused in semiconductor fabrication where the verybest cleanroom conditions arerequired.

T

L

SUPPLY PLENUM

RI

FLEX

VIERATION ISOLATOR

/

R.A.

=

RETURNAIR

Figure 6.5 Vertical flow cleanroom often used in semiconductor manufacturing

Unidirectional Clean Cleanrooms and

Air Devices

77

The design of semiconductor cleanrooms has evolved over several years, but a design that hasbeen popular for a number of years is shown in Figure 6.5. The air in Figure 6.5 flows in a unidirectional way from a ceiling of high efficiency filters anddown through the floor of the cleanroom.As the manufacturing of semiconductors is sensitive to vibration, and anti-vibration measures are incorporated. Some designs return the air from just below the floor, while other designs (similar to the type shown in Figure 6.5) use a large basement, that basement being used for services. Other designs have both the sub floorand a basement below. The design shownin Figure 6.5 is oRen called a ‘ballroom’ type because there is one large cleanroom. Typically, it is over 1000 m2 in floor area and some rooms are large enough to hold two football fields. It is expensive to run but adaptable. Figure 6.6 shows a photograph of a typical ‘ballroom’ cleanroom before production equipment wasinstalled.

Figure 6.6 Ballroom type of cleanroom

In the ‘ballroom’ type of cleanroom, a complete ceiling of high efficiency filters provide clean air throughout the whole room, irrespective of need, and the machinery stands throughout the room. However, the best quality air is only really necessary where the product is exposed to airborne contamination, and lesser quality should be acceptable in other areas.

Cleanroom Technology

78

Service area

\

Cleanr,oom

l ' (

\

a )b a l l r o o mt y p e

\

Cleanroom tynnel

\\

Cleanroom Mini environment

sbe)r v iccheatsymecpei)enniv i r o n m et ny pt e

IS0 3 ( C l a s s 1 ) o r b e t t e r

0I S 0

6 (Class 1000)or worse

Figure 6.7 Plan viewsof three typesof cleanrooms

Usingthisconcept,lessexpensivecleanroomshavebeendesigned.One such design is that where service chases with lower cleanliness standards are inter-dispersed with cleanroom tunnels. This concept shown is in Figure 6.7 (b), and a photograph of a cleanroom tunnel is shown in Figure 6.8.

Figure 6.8 Cleanroom tunnel design

Unidirectional Cleanrooms

and Clean Air Devices

79

Service technicians can gain access to bulkhead-fitted machinery through the service chases without entering the clean space where the semiconductor wafers are exposed. Less expensive air conditions are provided in these service chases. It is also possible in the ballroom type of design to divide up the ‘ballroom’ with prefabricated walls and provide clean tunnel and service chases; these walls can be dismantled and reassembled in a different configuration should the need arise. Service chases and other less critical areas of the cleanroom are normally supplied with lesser quantities of air and have a lower standard of air cleanliness. This can be achieved by reducing the ceiling filter coverage by means of ceiling blanks; this method is shown diagrammatically in Figure 6.9. If this method is used, it is best to distribute the filters evenly around the ceiling. If the filters are grouped together in lines or rectangles the area under the filters will be better, but away from them will be poorer. As the cleanroom classification is determined by the poorest particle count this design may result in a poorer classification. Another alternative is to use 100% filter coverage and reduce the overall air velocity. This design is likely to give better air movement that a filter ceiling with less than 100% coverage and hence will give lower particle counts. However, it will be more expensive to build.

RAISED F L O O R

II

I

II

Figure 6.9 Reduced ceiling filter coverage to give non-unidirectional conditions

Technology

80

Cleanroom

If either of these two methods is employed, use may be made of Table 6.1 to calculate the percentage of filter coverage. Table 6.1 is published in the Recommended Practice RP CC012 of the IEST, although the nomenclature of the room classification has been changed to that used in this book. It should be noted that 100 ft/min = 0.5 m/s, approximately. Table 6.1 Air velocities in cleanrooms Class of cleanroom

Airflow type

Average velocity (ftJmin)

Air changeshr

I S 0 8 (100,000)

N/M

1-8

5-48

I S 0 7 (10,000)

N/M

10-15

60-90

I S 0 6 (1,000)

N/M

150-240 25-40

I S 0 5 (100)

U/N/M 240-480 40-80

I S 0 4 (10)

U

50-90

I S 0 3 (1)

U

360-54060-90

than better

IS0 3

Air changes per hour

U

=

60-100

300-540

360-600

Average airflow velocity' x room area Room Volume

x 60 min / hr

* taken over the whole supply ceiling N = nonunidirectional; M = mixed flow room ; U = unidirectional flow. The values used in Table 6.1 should only be used as a guide and I consider that too much airis required to achieve the cleanroom classifications in nonunidirectional room conditions.

Unidirectional Cleanrooms and Clean Air Devices

81

If the cleanroom design uses an air supply plenum then the unfiltered air in the plenum above the filters will be at a higher pressure than the air in the cleanroom. Unfiltered air can therefore leak from the supply plenum into the cleanroom through badly sealed, or unsealed, joints in the structure. This problem is discussed in Chapter 11 and shown in Figure 11.l. Such problems can be overcome if the area above the ceiling is below the pressure of the cleanroom. This can be achieved by individually supplying the filter housings with ducted air, or by using individual fan-filter modules. These methods are often used when the filter coverage is less than 100%.

6.2 Clean Air Devices Clean air devices are used in cleanrooms to provide a higher quality of air to critical areas where products or processes are open to contamination. Types of enhanced clean air devices that are available are: unidirectional flow benches, unidirectional flow work stations, isolators and minienvironments. The use of clean air devices in a turbulently ventilated room is popular, and is the most common configuration of cleanroom. By this method, the best air conditions are provided only where they are needed and considerable cost savings are made compared to providing a full unidirectional cleanroom.

6.2. I

Unidirectional air devices

Figure 6.10 is adrawing of a horizontal flow cabinet; this is one of the simplest and most effective methods of controlling contamination. The operator sits at the bench and works on materials, or at a process, placed on the bench top. The operator’s contamination is thus kept downwind of the critical process. Also available are a variety of styles of unidirectional flow systems that may vary in size to encompass any size of production machinery. Figure 6.1 1 shows a vertical flow unidirectional work station placed over a filling machine. The airflow in the cleanroom is turbulent but the product is protected from contamination by being filled in a unidirectional flow of air.

82

Technology

Cleanroom

HEPA FILTERS

PLENUM CONTAINING FANS

Figure 6.10 Horizontal flow cabinet

Air plenum

containing fans

HEPA Plastic sheeting to contain air

Figure 6.1 1 Vertical flow work station over production machinery

Unidirectional Clean Cleanrooms and

6.2.2

Air Devices

83

Isolators and minienvironments

A reduction in capital and running costs of a cleanroom is always sought, especiallyifthis canbe accompanied by an increase in product yield brought about by enhanced contamination control. There has thereforebeen much use of what have been variously called ‘isolators’, ‘barrier technology’ and ‘minienvironments’.Minienvironmentsisthe term commonly used in the semiconductor industry, the other twowords are used mainly in the pharmaceutical industry. 6.2.2.1 Semiconductorapplications A minienvironment uses a physical barrier (usually plastic sheet or glass) to isolatethecriticalmanufacturingarea and provideit with the very best quality of air. The rest of the room can then be provided with lower quantities of air.

I

4J

Figure 6.12 Design of unidirectional system with service chase

Figure 6.12 is a diagram of the air supply design without a minienvironment. In this design, large quantities of a unidirectionalflow of air are provided to give the best conditions (shown as whitein Figure 6.12 and desig-

84

Technology

Cleanroom

nated I S 0 Class 3) in those parts of the room where the operators move silicon wafers from machine to machine. Lesser quantities of air are provided for the service chaseswhere the bulkhead-fitted machines are serviced (shaded area and designated IS0 Class 6). Figure 6.13 is a diagram of an air supply design that uses minienvironments. The minienvironment (shown as white and designated as IS0 Class 3) then provides the highest quality of environment. A lesser quality of environment (IS0 Class 6, or poorer) isprovided in both the production areas and the service chase. The total air supply volume is much less with this minienvironment design (see also Figure 6.6). It is seen in Figure 6.13 that the air velocity in the minienvironment is shown as 0.4 m / s (80 ft/min). This is the speed associated with low particle counts in occupied cleanrooms. However, there are no personnel within the minienvironment causing turbulence and if the machinery is not giving off disruptive thermal up-currents then a lower air velocity may suffice. The minimum velocity that is suitable will have to be determined by use of air visualisation techniques described in Section 11.2.

Figure 6.13 Semiconductor fabrication room with a SMIF isolation system

Devices Unidirectional AirClean Cleanrooms and

85

As well as using a minienvironment to isolate the area where the silicon wafers are exposed, the wafers can also be transported between processing machines in specially designed carriers (SMIF Pods), which prevent the wafers being contaminated by the air outside. These pods are slotted into the machine through a Standard Mechanical Interface Format (SMIF). The wafers are processed and then loaded back into a carrier; it is detached and taken to another machine and loaded into its interface. The transfer of the carrier is usually done by a person but automatic handling systems are also used. Various types of minienvironments, with different methods of accessing the wafers into the production machines, have been developed. As long as these are well designed, particularly with respect to the container for the wafer cassettes and the transfer port, they will work well. 6.2.2.2 Other cleanroom applications Isolator and barrier technology has been applied successfully to pharmaceutical and other types of manufacturing. They can be used to either protect the product fiom contamination, personnel from toxic compounds, or in some cases, both. Isolators can be purchased with various design attributes. Some of these design attributes are shown in Figure 6.14. Design attributes of an isolator that should be considered are as follows: whether they are positively or negatively pressurised with respect to the room they are situated; the type of transfer systems for the entry and exit of materials; methods to be used for manipulating inside the isolator. The cleanliness of the product, or process, inside an isolator will be maintained by using a positively pressurised isolator. Internal pressures in the order of 20 to 70 Pa, compared to the surroundings, are typical. Where hazard containment is required, a negative pressure system is used. The type of transfer device selected for transferring items in and out of an isolator will greatly influence its efficiency. Figure 6.14 shows both a pass-through sterilising tunnel and a transfer-docking device.

Technology

86

Cleanroom

Exhark

fl

and Ventilation

Pass-tt tunnel

Transfer methods

m Manipulationmethods Figure 6.14

An isolator with its various components

Docking devices arethe most efficient method of ensuring that the materials pass into an isolator without being contaminated. They may also be used to connect or separate individual isolators. The sequence shown in figure 6.15 illustrates the operating principles of a typical transfer device. This docking port method is the most secure, but it is not the easiest method of manipulating materials in and out of an isolator. Other simpler methods are available. A transfer hatch, or pass box, can be used where the manufacturing or testing, is being carried out in batches. Figure 6.16 illustrates an isolator with transfer hatch, or pass box, on each side. These can be provided with an appropriatecombination of interlocked doors andventilation. When the manufacturing process is continuous, as with large scale manufacturing, then it is more convenient if the product can be continually

Devices Air Unidirectional Clean Cleanrooms and

87

transferred out of the isolator. This can be by either using a final holding isolator and one of the methods described above. A aerodynamically designed ‘mouse hole’ or transfer tunnel, can be used together with an outward flow ofair (see Figure 6.14). Most isolators require people to manipulateproducts within the isolators. This is achieved by the use of glove ports or half suits. These two methods are illustrated in Figure 6.14. Figure 6.17 also shows the inside of an isolator and twooperators working withhalf suits. Step 1

Container (or transport isolator) approaches closed isolator port.

Step 2

Container docks with port and rotates to lock and enclose exposed faces. At the is released on the isolator door. same time the interlock

88

Technology

Cleanroom

Step 3

Door into isolator is opened to allow free communication between the two enclosed volumes.

Figure 6.15 Operation of a transfer port

Figure 6.16 Photograph of an isolator with transfer chambers

Unidirectional Cleanrooms

and Clean Air Devices

89

Figure 6.17 View of half suits and inside of isolator

Acknowledgements Figures 6.5 and 6.9 are reproduced by permission of Gordon King. Figure 6.6 is reproduced by permission of M+W Pearce. Figure 6.8 is reproduced by permission of Roger Diener of Analog Devices. Figures 6.12and 6.13 are reproduced by permission of Asyst Technologies. Figures 6.14,6.15 and 6.17 are reproduced by permission of La Calhene. Figure 6.16 is reproduced by permission of Envair. Table 6.1 is reproduced by permission of the Institute of Environmental Sciences and Technology.

7 Construction Materials and Surface Finishes 7.1 General Requirements A cleanroom requires a higher standard of construction than many other buildings. Construction materials used to build cleanrooms differ from those used in non-cleanroom construction for the following reasons: A cleanroom should be built with an airtight structure. The internal surface finish should be smooth and suitable for cleaning. The internal surface finish should be sufficiently tough to resist chipping or powdering when impactedor abraded. Some process chemicals, cleaning agents, disinfectants and water may attack or penetrate conventional finishes. In some cleanrooms, electro-dissipative construction materials will be required. Insome cleanrooms, construction materials that give a minimum of ‘outgassing’ will be required.

Cleanrooms are maintained at a positive pressure with respect to adjacent areas. If the construction is poor and the joints not well sealed, then the structure may leak too much. It may then be necessary to pressurise the roomby excessive amountsof‘make up’ outside air. It is not good economic sense to waste air that has to be expensively filtered and airconditioned. Attempting to seal up the structure during the ‘snagging’ part of the construction will not be as successfil as making it airtight during

92

Technology

Cleanroom

construction. Containment rooms that are maintained at a negative pressure must be airtight, as dirty unfiltered air will be drawn into the room through cracks, joints and at service penetration points in the fabric. The materials that are used for the construction of a cleanroom should be smooth on the surface facing the inside of the cleanroom. There should be no pores or roughness that will retain contamination. The surface should be free of ledges and easily wiped free of any contamination that is deposited. The butts and joints, as seen from the inside of the cleanroom, should not show openings that may harbour, and then disperse, dirt. The surface finish in a cleanroom must not break up easily and disperse chips or particles of material. A conventional material that is often used in houses and offices is plasterboard that is nailed to stud partitions and then painted. If this material is struckheavily the plaster powder willbe released. This is unacceptable in a cleanroom and surface finishes must be suitably resistant to impact. Cleanroom surfaces, especially floors, should be able to withstand liquids usedin cleanrooms. Some processes use strong acids or solvents that will attack surfaces. Cleanrooms, where micro-organisms cause contamination, will require disinfection. Disinfectants are inan aqueous solution and to correctly disinfect the surface the contact time should be several minutes; water penetration can occur if construction materials are not suitable. Similar problems can occur when cleaning the cleanroom with surfactant solutions. It is therefore necessary to ensure that penetration of water does not occur, as this can produce conditions that are suitable for microbial growth. It should, however, be noted that it is incorrect to suggest that micro-organisms sitting in dry conditions in cracks and pores will multiply. Micro-organisms are aquatic in nature, and unless free water is available, or the relative humidity is very much higherthanfoundin a cleanroom, growth will not occur. An electrostatic charge can be generated by rubbing two dissimilar surfaces together and can give two problems. Firstly, the charge will attract particles from the air and those deposited particles may give a contamination problem. Secondly, electrostatic discharge can cause some components to fail. Construction materials that minimise this problem may be necessary in some cleanrooms.

Construction

93

Some chemicals can ‘outgas’ from the materials used in construction of cleanrooms. These outgassed chemicals are often called ‘molecular contamination’. some In cleanrooms, such as those required for manufacturing optical surfaces or semiconductors, the deposition of these materials onto the product may be unacceptable. Where this is a problem, construction materials that do not outgas will be required. Cleanrooms can be constructed in various ways. However, despite the fact that some construction methods will not fit easily into either group, the building techniques can be discussed under two headings: conventional and modular. These are discussed below.

7.2 Conventional Building Techniques Conventional building techniques, suitably modified, canbeusedin cleanroom construction. The building used to house the cleanroom suite will be conventionally constructed with floor, ceiling and external walls. Inside that structure, internal walls will become the various rooms of the cleanroom suite. These are constructed using conventional techniques employing bricks or blocks and finished using wet plastering or dry lining methods. The dry finishing method is the most popular method as this employs less site time, is more easily repaired and allows the electricity, and other services such as air ducts to be run behind. At its simplest, wall studs are used and these are lined with plasterboard. The boards are taped, primed and painted. The paint is sprayed onand will bechosen to give good impact resistance, e.g. epoxy-based types. To assist cleaning, wall-to-wall comers are best constructed with 25 mm ( l inch) to 50 mm ( 2 inch) diameter curves. The corner where the wall meets the floor would normally be finished with a 100 mm (4 inch) quarter-round coving. If this method is used, it would only be suitable for lightly-used cleanrooms of about IS0 Class 8 (Class 100 000), or for approach corridors or controlled areas outside the cleanroom. A considerable improvement in the quality of the cleanroomcanbe achieved by lining the frames with various sheets of cleanroom-compatible material; this will also enhance the look of the cleanroom.

94

Cleanroom Technolow

Figure 7.1 Cleanroom change area showing gooduse of curves

The panels will be thinner - from about 3mm to 12 mm (1/8 inch to '/z inch) depending on their strength and rigidity - than the studless system used in modular construction because the frames will give additional rigidity. The following wall panels can be used: Panels laminated with an outer cleanroom-compatible surface and an inner-strengthening core. Outer surfaces can be (a) mild steel that is galvanised and either powder coated or enamelled, (b) plastic sheets or (c) aluminium that is either anodised, powder coated or enamelled. Inner core materials can be plaster, composite board, plywood, honeycombing, etc.; Glass-reinforced epoxy sheets; Mild steel sheets thatare galvanised and eitherpowder coated or enamelled;

Construction

0

95

Aluminium sheets that are anodised, powder coated or enamelled; Stainless steel sheets, with or without a suitable paint finish.

Many other combinations and materials can be used, as long as they fulfil the criteria defined in the first section of this chapter.

7.3 Modular Construction Modular construction is the type of construction where components are delivered ready-made and assembled on site. A large variety of modular components are available from firms who specialise in manufacturing such systems. Inevitably, the most easily assembled, best looking and most robust system, with the least likelihood of contamination problems, will be the most expensive. It is therefore necessary to choose wisely, balancing the quality and cost of the products with the advantages they bring. The two principal ways a modular systemare assembled are:

0

Studless wall systems Framed wall constructions.

7.3.l Studless wall systems These are normally assembled from wall panels that are about 50 mm (2 inch) thick for rigidity; these are slotted into ceiling and floor mounted tracks. These tracks are usually anodised aluminium extrusions and the wall panels are butted together. Figure 7.2 shows a drawing of the ceiling and floor details of a high quality system of this type. Figure 7.3 shows ceiling and floor details of a less expensive system of this type. The wall panels are laminated from an outer cleanroom compatible surface and inner-strengthening core. Outer surfaces can be plastic sheets, aluminium that is either anodised, powder coated or enamelled, and suitably treated mild steel. Inner core materials can be plaster, composite board, plywood, honeycombing,etc.

96

Technology

[returned over

Cleanroom

/ Aluminium extrusion

Silicone sealant Adjustable epoxy Countersunk screw

flooring Floor Epoxy fixings

Figure 7.2 Cross-section of ceiling and floor details of high quality modular

system

7.3.2 Framed wall systems These systems arebuilt from joined aluminium extrusions. If this method is used for a room, the studs and cross members are clad with wall panels either on one side (single shell) or on both (double shells). Wall panels used in this type of construction will be made of the same types of materials as discussed above, although they will be thinner.

Ceiling Ceilina Panel

ground floor Floor fixings

\ Aluminium

Floor Figure 7.3 Cross-section of less expensive ceiling and floor details used in a modular construction system

Framed systems are also used where process machinery is isolated from the rest of the room. Isolators or minienvironments, as well as safety screens roundmachinery, are examples of this use. Lightweightaluminium extrusions are connected together to give a framework round the machinery and panels made of aluminium sheet, glass or clear plastic are glazed into the frames by use of special easy-to-clean gaskets.

98

Technolopy

Cleanroom

7.4 Doors and Windows Probably the most popular types of cleanroom doors are made either from plastic covered wood, or faced with mild steel that is suitably treated and painted. To assist cleaning and minimise hand contamination, door fittings such as doorhandles should be dispensed with where possible. Doorswould usually be hung so they would be kept closed by the positive pressure of the cleanroom. However, exceptions may be required so that personnel can pass through by pushing the door with their body. In that case, a self-closer should be fitted. Doors are often manufactured with fine tolerances to minimise air leakage. This is a particularly useful property in a negatively pressurised containment room to minimise the entry of contamination from outside the room. However, in positively pressurised rooms this may be unnecessary, especially if the design requires air to flow through the doorway when open (see Section 5. l .4). Doorsmay be glazed, whichis particularly useful in the materials transfer airlock to see if it is occupied. If glazing is required, the method of glazing (i.e. gaskets) should allow easy cleaning. Doors that are completely made of glass are also available. Windows are fitted to cleanrooms. These are useful in dissuading visitors who have come to see the cleanroom from entering; they are also necessary to allow management to see what is going on in the room without having the bother ofchanging into cleanroom clothing. Their number should, however be kept to a minimum. Windows should be glazed using easy-to-clean gaskets.

7.5 Floors Concretewouldbe used as a common floor foundation in almost all cleanrooms. A smooth, impervious and durable surface would then be added. This should be resistant to spilled chemicals and be slip resistant. It may also be necessary in some situations to use materials that have good electrostatic or minimal outgassing properties.

Construction

99

A commonly used method of covering the floor is with vinyl sheeting that is welded together. A less common surface covering is terrazzo, which is very durable and is suitable in some situations. Vinyl sheeting can be manufactured to be electrically conductive for use where this is desirable. In unidirectional flow rooms, where the air passes through the floor, it would be commonto find that the floor is made oftiles placed on pedestals. If the room is used for semiconductor manufacturing, vinyl may not be an acceptable surface material because of the problem of ‘outgassing’. The floor-to-wall joints would normally be coved with some type of corner profile. An exception to this requirement may be where machines are used to clean the floor.

7.6 Ceilings It would beunusual to have anything but a false ceiling in a cleanroom. The need for access to air conditioning ducts and other gas and electricity services, and the use of terminal filters and recessed lights that are integrated with the ceiling, dictates the use of a suspended or supported ceiling. In conventionally ventilated cleanrooms the ceiling would be either of the suspended or self-supported type. Into the space between the support channels, the light fittings and air filter housings would be placed, the remaining areas being fitted with blank panels. Figure 7.4 is a photograph of a suspended cleanroomceiling suitable for walking on, and showing the various components. All of the light fittings, filter modules and blank panels must be well fitted to ensure a minimum of air leakage. If top-quality components are not used, mastic or other means can be used tobeddown the various components. In unidirectional flow cleanrooms, most of the ceiling is covered with filters. In that case, the ceiling is built of aluminium extruded channels and the filters are inserted into the channels. This is discussed in Sections 6.1.3 and 8.6 of this book.

100

Technology

Cleanroom

Filter housing

/

Figure 7.4

Suspended cleanroom ceiling

7.7 Outgassing and Electrostatic Properties In semiconductor and similar areas, the use of construction materials that allow chemicals to ‘outgas’ can give contamination problems. Cleanroom flooring will often be plastic sheeting. Vinyl flooring is made of PVC with other materials added, one of these being a plasticiser to make it flexible. These plasticisers will outgas and are therefore not a good choice for semiconductor cleanrooms, especially as the floor has a large surface area. Sometypes of wall and ceiling panels may alsobe considered a risk. Another material that is considered a risk is silicon sealant used for sealing various joints. More suitable sealants can be purchased. Adhesives may also be a problem.

Construction

101

Test methods are available to ascertain the outgassing properties of materials. Thesecan accelerate the ‘outgassing’ of contamination and assess the amount that will condense onto a surface. If static charge is considered a problem, then the construction materials shouldbe conductive and earthed to dissipate the electrostatic charge. However,if there isno electrical resistance there will be a danger to personnel throughan electrical accident. It has been suggested that the electrical resistance should therefore be between lo6and lo9 ohmskm.

Acknowledgement Figure 7.1 is reproduced with permission of Thermal Transfer. Figures 7.2, 7.3 and 7.4 are reproduced with permission of MSS Clean Technology.

High Efficiency Air Filtration 8.1 Air Filters used in Cleanrooms The air supplied to a cleanroom must be filtered to ensure the removal of particles and micro-organisms. Until the early 1980s, High Efficiency Particulate Air (HEPA) filters filtered cleanroom air, as these were the most efficient air filters available. A HEPA filter has a minimum efficiency in removing small airborne particles, approximately equal to 0.3pm, of 99.97%. Today, HEPA filters are still used in most cleanrooms to remove the microorganisms and inert particles in the supply air. The production of integrated circuits has now evolved to a level where more efficient filters than HEPA filters are required to ensure that fewer and smaller particles pass through the air filters and into the cleanroom. Better filters are used and these are known as Ultra Low Penetration Air (ULPA) filters. An ULPA filter will have an efficiency greater than 99.999% against 0.1-0.2 pm particles. These filters are constructed and function in the same way as a HEPA filter. It is generally accepted that For cleanrooms of IS0 Class 6 (Class 1000) and poorer quality, HEPA filters are used with turbulent ventilation to meet the cleanroom classification. For I S 0 Class 5 (Class loo), HEPA filters that completely cover the ceiling are used to supply unidirectional flow down through the cleanroom. For I S 0 Class 4 (Class 10) or lower, ULPA filters should be used with unidirectional flow.

104

8.2 The Construction of High Efficiency Filters High efficiency filters are usually constructed in two ways, i.e. deep-pleated or mini-pleated. Ina deep-pleated filter, which is the more traditional construction method, rolls of filter paper are folded back and forward, side by side, either in 15 cm (6 inches) or 30 cm (12 inch) widths. To allow the air to pass through the paper and give the filter strength, a crinkled sheet of aluminium foil is often used as a separator. This pack of filter media and separators is then glued into a frame of a plastic, wood or metal. A crosssection of this traditional construction is shown in Figure 8.1.

Frame

Sealant

tor FiIter .Qd ia

-S,

Figure 8.1 Deep-pleated high efficiency filter with separators

High Efficiency Filters

105

High efficiency filters are now most commonly available in a mini-pleat form. Aluminium separators are not used in this method of construction but the paper medium is folded over ribbons, glued strings, or raised dimples in the media and assembled into a frame. This method of assembly allows 2.5 to 3 times more pleats than the deep-pleated filters and can therefore be made more compact. Mini-pleated construction is the most widely used method of construction for unidirectional flow cleanroombecausethe larger media area yields a lowerpressuredrop than deep-pleatedconstruction.Sucha method of construction is shownin Figure 8.2.

Figure 8.2 Section of a mini-pleated filter

106

Technology

Cleanroom

The pressure drop across a filter is dependenton the air velocity through the filter media and its type of construction. The nominal air velocity through a filter is usually considered to be 0.5 m / s (100 Wmin). At this velocity the pressure drop is likely to be between 120 Pa and 170 Pa. When the pressure drop reaches 2.5 to 3 times the original pressure, the filters are normally replaced.

8.3 Particle Removal Mechanisms A high efficiency filter is designed to remove particles of about 2 pm and smaller. Much lessexpensive pre-filters can be used toremovelarger particles and these are not discussed in this chapter. High efficiency filter media is madeof glass fibres ranging in diameter from as little as 0.1 pm and up to 10 pm, with spaces between fibres often very much larger than the particles captured. AnULPA filter will use a higher proportionof finer fibres than a HEPA filter.

Figure 8.3 Photomicrograph of high efficiency filter media

High Efficiency

107

These fibres criss-cross randomly throughout the depth of the filter media and do not give a controlled pore size. A photomicrograph of high efficiency filter media is shown in Figure 8.3. A 10 pm scale is shown at the base of the photograph. As airborne particles move through the filter paper, they bump into the fibres, or onto other particles that are already stuck to the fibres. When a particle bumps into either a fibre or a particle, strong forces, such as Van der Waal’s, are established between the captured particle and the fibre or particle that has captured it; these retain the particle. DIFFUSION

Fibre

IMPACTION

Fibre

INTERCEPTION

Fibre

SCREENING

Fibre

Fibre

Figure 8.4

Particleremovalmechanisms

108

Technology

Cleanroom

The three main mechanisms involved in the removal of small particles in filter media are impaction, diffusion and interception. Sieving or straining is of much less importance as this occurs only with larger particles sizesthat are removed by primary filters placed before the high efficiency filters. These fourmechanismsareshowndiagrammaticallyinFigure 8.4. It maybe assumed that electrostatic effects are generallyunimportant in high efficiency filters and for that reason are not included in the figure. In the process of capture by difluusion (also known as Brownian movement), small particles (i.e. those without sufficient mass to leave the gas stream on their own) move about randomly. This random motion from these small particles is caused by constant bombardment by other small particles andthemolecules of thegas in which they are suspended. Thisrandom motion causes the smaller particles to move about and they may touch the fibres of the filter or previouslycaptured particles. In the process of capture by impaction, particles large enough (i.e. with enough mass) to have sufficient momentum leave the gas stream and strike a fibre as the gas turns around a fibre.If a particle strikes a fibre as it passes it, i.e. tangentially, it will be captured and retained, this mechanism being known as interception. The final mechanism of filtration, which is known as sieving or straining, occurs when the spaces between the fibres are smaller than the particles that arebeing captured. A high efficiency filter is dependent on the first three of the mechanisms described above to remove particles in the air. The largest size of particles is removed by inertial impaction, the medium sizeby direct interception and the smallest by diffusion. This concept is demonstrated in Figure 8.5. This figure shows the classical removal efficiency curve for a HEPA-type filter and a ‘most minimumefficiencyfora particle size of about 0.3 pm.This penetrating size’ normally varies between 0.1 pmand 0.3 pm.It also is interesting to note that high efficiency filtersaremoreefficient against particles than are smaller than the most penetrating size; this effect is caused by diffusion. The curve gives a rather simplisticapproach. It is known that the particle size that has the minimum removal efficiency (or the maximum penetrating particle size) varies depending on variables such as the density of a particle and the typeof filter medium.

High

109

F

a, .-

1 .o

-

0.8

-

Oh

-

0

E

0.4-

0.2

-

Diffusion

Diffusionand : Interception :

d.5

l

Impaction

1-,o

Particlediameter, W

Figure 8.5

Classical efficiency curve foran air filter

8.4 Testing of High Efficiency Filters High efficiency filters are tested after manufacture to measure their efficiency against test particles. There are a number of tests used for this purpose. The best known are:

8.4.1 Military Standard 282 This USA test originally used thermally generatedparticles of di-octyl phthalate (DOP)with anaveragesize of 0.3 pm to test the efficiency of HEPA filters. However, other oils such as poly-alpha olefin (PAO) or di-octyl sebacate (DOS) have replaced DOP. Heating such an oil produces an oil mist, and the efficiency againstthis challenge is determined.

110

Technology

Cleanroom

8.4.2 Sodium Flame Test (Eurovent 4/4) This European test method for HEPA filters uses an aerosol of particles of sodium chloride that have a mass median size of 0.6 pm. The test aerosol is sprayed into the airas an aqueous solution and the dry particles that are formed are used to determine the filter’s efficiency.

8.4.3 Institute of Environmental Sciences (IEST) Recommended Practice ‘Testing ULPA Filters ’. The Institute of Environmental Sciences and Technology (IEST) has developed a Recommended Practice for testing ULPA filters (IEST-RPCC007). An optical particle counter is used to measure particles, although a condensation nuclei countercanbe used to extend the lower range. The choice of the aerosol material is left to the user, but must meet certain optical properties. This test system provides a particle size efficiency in size ranges from around 0.07 pm to 3.0 pm.

8.4.4 European Standard (EN 1822) This standard is used for both HEPA and ULPA filters and gives a method for testing the particle removal efficiency and classifying the filter. An important departure of this test method fromthe methods outlined above is the determination of the Most Penetrating Particle Size (MPPS) for the filter media being tested, and the measurement of the removal efficiency of the filter at that particle size. As discussed in Section 8.3, each filter has a particular particle size that will pass through the filter most easily, that size being determined by variables, such as the fibre content of the filter media, air velocity and its packing density. It is logical therefore to test the filter at that most penetrating particle size. The MPPS isnormally between 0.1 pm and 0.3 pm. The first stage of this test method is to determine the MPPS of the flat sheet filter medium used in the filter. This is carried out at the face velocity that will correspond with that produced by the filter when working at its given

High

111

flow rates. The efficiency of the complete filter canthen be determined in two ways:

0

Leak testing (local efficiency). The filter mediaof the complete filter is scanned to determine the amountof leakage through pinholes in the filter medium. Overall efficiency. The efficiency of the complete filter is determined at its rated flow.

The filter is then classified by its overall and local efficiency against its most penetrating particle. This classificationis shown in Table 8.1. Table 8.1 Classification of filters according to the EN 1822.

Filter class

Overall value efficiency

m’.> H 10 H 11 H 12 H 13 H 14 U 15 U 16 U 17

85 95 99.5 99.95 99.995 99.999 5 99.999 95 99.999 995

Overall value penetration

m’.>

15 5 0.5 0.05 0.005 0.000 5 0.000 05 0.000 005

Leak test Efficiency

Leak test penetration

(%l

@’.>

-

-

-

-

-

0.25 0.025 0.002 5

99.75 99.975 99.997 5 99.999 75 99.999 9

0.000 25 0.000 1

8.5 Probe (Scan) Testing of High Efficiency Filters Air that is supplied in a turbulently ventilated cleanroom through diffusers in the ceiling is thoroughly mixed with the room air. Some pinhole leaks in the filters can be tolerated, as long as they are not great enough to significantly reduce the overall efficiency of the filtration system and affect the required

112

Technology

Cleanroom

aircleanliness.Thistolerance is possiblebecausethe small number of particles passing throughthe filter arewell mixed with the room air. Thisis not thecaseinunidirectionalflowsystems, where a leak can release a unidirectional stream of particles into the close proximityof the process or product. To preventthesepinholeleaks,thefilters shouldbe scanned in the factoryby introducing a test dust before the filter and scanning thewholefilter with overlapping passes usinga probe andsearchingfor leaks.Thismethodis very similar to thatdescribed in Chapter 12 of this book.

8.6 Filter Housings for High Efficiency Filters When high a efficiencyfilterleavesthefactorywhereithas been manufactured and tested, it should be fit for the purpose required. If it has been properly packed and transported, and installed by personnel who are familiar with thedelicate nature of filtermedia, then thefilter’s integrity should be maintained. To ensure that there is no ingress of unfiltered air into the cleanroom, the filter must be fitted into a well-designed housing. The housing must be of sound construction and particular attention must be paid to the method of housing/filter sealing. Neoprene rubber gaskets are commonly fitted to the filter frame as seals. This is illustrated in Figure8.1. When the filter is fitted into the filter housing the gasket presses down, compressing onto a flat face of the housingand 8.6). This method is preventingtheleakage of contaminatedair(Figure normally successful, but distortionof the filter frame or housings, assupplied or when tightening up, as well as poor or old gaskets, can cause leakage. Better-designed housings overcome these problems. Figure 8.7 shows a system that would be used in a unidirectional flow cleanroom. The ceiling grid has a continuous channel filled with the fluid seal, which is a jelly-like substance that will not flow out of the channel. A knife-edge fitted to the filter frame mates into the channel of sealant. The fluid flows round the knife-edge to give a perfect seal and prevents particles by-passing the filter throughthe housing.

High Efficiency Filters

113 RECIRCULATED AIR

Figure 8.6 Traditional neoprene gasket sealing method

Grid Support

Y

Figure 8.7 Ceiling grid with channel for a fluid seal

114

Technology

Cleanroom

Acknowledgements Figures 8.1, 8.2 and 8.7 are reproduced by permission of Flanders Filters. Figure 8.3 is reproduced by permission of Evanite Fiber Corporation. Table 8.1 is reproduced by permission of the British StandardsInstitution.

Cleanroom Testing and Monitoring When a cleanroom has been built and about to be handed over to the purchaser, or when an existing cleanroom is reopened after being shut down for modifications that could cause changes to its contamination control characteristics, it will be tested. This initial type of testing is to establish that the cleanroom is working correctly and achieving the contamination standards that it has been designed to fulfil. These standards are laid down in IS0 14644-1. A secondary function of this initial testing is to establish the initial performance of the room so that this can be adopted as a ‘benchmark’. When the room is checked in the future, either routinely or when a contamination problem is encountered, deviations from the original conditions may be found, and the possible reasons for contamination thus ascertained. The final and indirect reason for carrying out initial testing of a cleanroom is to familiarise and train the staff who will monitor and run the room. This may be their most important, and possibly only, opportunity to understand how their cleanroom works and learn the methods used to test and ensurethat the cleanroom continues to perform correctly. When it has been shown that the cleanroom fulfils the I S 0 14664-1 cleanroom classification set down at the design stage, it is necessary to regularly check the room at the time intervals set by IS0 14644-2, to ensure that the room continues to comply with the standard. Many cleanrooms are built and passed over to the user with little or no effort being put into ensuring that over its many years of use the correct level of cleanliness continues to be achieved. Testing must therefore be carried out so that the

116

Technology

Cleanroom

customer who buys theproduct made within the room gets a product that is fit for the purpose it is intended. As well as checking the cleanroom to show that it is working correctly when first installed and at regular intervals to show that it complies with I S 0 14644-1, it may be necessary to regularly monitor the room. This may not be required in poorer cleanrooms, but in higher quality rooms it may be necessary to monitor the room to ensure that the correct conditions are maintained during production. This testing may be either continually, or at intervals that are much shorterthat those laid down in IS0 14644-2 to show continued complience. Most of the tests carried out to test the initial performance, or demonstrate continual compliance, are identical to those used to monitor it, although it is normal to find that the initial testing is more thorough and extensive.

9.1. Principles of Cleanroom Testing To show that a cleanroom is working satisfactorily it is necessary to demonstrate that the following principles have been satisfied: The air supplied to the cleanroom is of sufficient quantity to dilute or remove the contamination generated in the room. The air within the cleanroom suite moves from clean to less-clean areas to minimise the movement of contaminated air. Air should move in the correct direction through doorways and the fabric of the room. The air supplied to the cleanroom is of a quality that will not add significantly to the contamination within the room. The air movement within the cleanroom should ensure that there are no areas within theroom with high concentrations of contamination If these principles are satisfied then the concentration of particles, and where necessary microbe-carrying particles, should be measured to ascertain that the specified cleanroom standard has been achieved.

Testing and Monitoring

117

9.2 Cleanroom Tests To ensure that the requirements in Section 9.1 are fulfilled, the tests shown in Figure 9.1 should be carried out, preferably in the order given. S TART ROOM AIR SUPPLY & EXTRACT OK? PASS AIR MOVEMENT BETWEEN AREAS I

PAS S FILTER INSTALLATION LEAK TE I

PAS S C O N T A I N M E N TL E A K A G ET I S I

PAS S

4

A I R M O V E M E N T IN ROOM OK? PAS S PARTICLE COUNT PAS S

+

COMPLIANCE

Figure 9.1 Cleanroom test sequence

9.2.l Air supply and extract quantities In the case of turbulently ventilated cleanrooms the air supply and extract volumes should be measured. In the case of unidirectional airflow it should be the air velocity.

118

Technology

Cleanroom

9.2.2 Air movement control between areas To demonstrate thatthe airflow between areas is in the correct direction i.e. from the clean to theless-clean, it is necessary to check that: The pressure differences between areas are correct. The air direction through doorways, hatches, etc. is from clean to lessclean.

9.2.3 Filter installation leak test The high efficiency air filter, and its housing, should be checked to ensure that no airborne contamination passes into the cleanroom through (a)a damaged filter (b) between thefilter and its housing or (c) any other part of the filter installation.

9.2.4 Containment leak testing Testing should be carried out to show that airborne contamination is not entering the cleanroom through its construction materials.

9.2.5 Air movement control within the room The type of air movement control tests depend on whether the room is turbulently or unidirectionally ventilated. If the cleanroom is turbulently ventilated then it is necessary to check that there are no areas within the room with insufficient air movement. If the room has unidirectional airflow, it is necessary to check that the air velocity and direction throughout the room is that specified in the design.

9.2.6 Airborne particles and microbial concentrations If the above tests are satisfactory then final measurements will be carried out to ascertain that the concentration of particles, and where appropriate micro-organisms, comply with the design specification laid down for the room.

Testing and Monitoring

119

9.2.7 Additional tests As well as these contamination control tests, it may be necessary to satisfy one ormore of the following requirements: 0 0

0 0 0

0

temperature relative humidity heating and cooling capabilities of the room sound levels lighting levels vibration levels.

These additional requirements are not considered in any detail in this book, as they are tests that may be required in air conditioned rooms other than cleanrooms. Information on these types of tests are available in various building services textbooks and in Guides provided by the American Society Heating Refrigeration and Airconditioning Engineers (ASHRAE) in the USA, and the Chartered Institute of Building Services Engineers (CIBSE) in the UK.

9.3 Testing in Relation to Room Type and Occupation State The type of tests to be carried out in a cleanroom depend on whether the room is unidirectional, turbulent or mixed airflow (a mixed flow room is onethatis turbulently ventilated but has unidirectional flow cabinets, workstations, or isolators within the room). The types oftests required with respect to the type of cleanroom are discussed in the chapters that follow. Tests can be carried out in the cleanroom when it is (a) ‘as-built’ i.e. in the empty room, (b) ‘at rest’ i.e. the room fitted with machinery but no personnel present or (c) ‘fully operational’. These occupancy states are discussed more fully in Section 3.4 of this book. When the cleanroom is being handed over to the user the initial testing is usually done in the ‘as built’ condition. Similarly, when the cleanroom is checked throughout its life to demonstrate that it complies with I S 0 14644-1, it will be normally tested in

Technology

120

Cleanroom

the ‘at rest’ condition. This will demonstrate that the cleanroom is working correctly. However, if the cleanroom is being monitored to demonstrate that the conditions in the room are acceptable for production, the testing will be done in the ‘fully operational’ condition. The type of tests required in each of the occupational states are very similar and any differences are described in next few chapters.

9.4 Re-testing to Demonstrate Compliance It is necessary to ensure that a cleanroom performs satisfactorily throughout its life andcontinuestocomply with itscleanroomclassification.The cleanroom must therefore be checked at regular intervals, these intervals being more frequent in higher specified rooms. Table 9.2 Schedule of tests to demonstrate continuing compliance.

s Parameter Test Interval To demonstrate compliance particle counting

Schedule of additional tests Airflow velocity or volume Air pressure difference Schedule of optional tests Installed filter leakage Airflow visualisation Recovery Containment leakage *= suggested time interval

by

5 IS05

6 months

> IS0 5

12 months

all classes

12 months

all classes

12 months

all classes

24 months*

all classes

24 months*

all classes

24 months*

all classes

24 months*

Testing and Monitoring

121

I S 0 14644-2 gives the maximum time interval that a cleanroom should be left before being tested to show it still complies with I S 0 14644-1. These maximum time intervals are listed in Table 9.2 along with the type of test. The one test that must be carried out to demonstrate that a cleanroom continues to comply with IS0 14644-1 is particle concentration testing. This must be carried out at a maximum time interval of 6 months for a cleanroom with a classification of 5 I S 0 Class 5 , or 12 months if the classification is over IS0 Class 5 . Particle counting tests are normally carried out in the ‘at-rest’ state but may also be carried out in the ‘operational’ state. If the installation has a continuous, or frequent, particle and air pressure difference monitoring system, then I S 0 14644-2 allows the time interval to be extended. Where the application requires them, ‘additional’ tests to demonstrate compliance are added. These are air velocity or volume, and air pressure difference testing. These must be tested at a maximum interval of 12 months, although the time interval can be extended if continuous, or frequent, monitoring is used. The IS0 14644-2 standard also allow ‘optional’ tests to be included in the testing if agreed by customer and supplier. These should be tested at a maximum test interval of 24 months. However, in this case these are only suggested time intervals. These tests are as follows:

0

0 0

The filter is installed correctly. The air movement within the cleanroom is correct i.e. airflow visualization tests. Any contamination dispersed is removed efficiently i.e. recovery test. The air is moving in the correct direction through the cleanroom fabric, i.e. from clean to less-clean.

All of the above tests are discussed in subsequent chapters of this book.

9.5 Monitoring of Cleanrooms The time intervals, and tests to be carried out, to show that a cleanroom continues to comply with I S 0 standard 14644-1 are provided in I S 0

122

Technolopy

Cleanroom

14644-2. In cleanrooms of a high standard, where cleanliness is a vital part of the production process, hrther testing or monitoring, may be required. This will be carried out to show that during production the cleanroom conditions are acceptable, and under control. It is suggested in IS0 14644-2 that the user should use a risk assessment to decide what monitoring tests should be doneand how often. The variables that are most likely to be monitored are:

0 0

air pressure difference airborne particle count where appropriate, microbiological counts.

Air pressure difference can be measured and recorded continuously by measuring instruments. This might be necessary in high quality cleanrooms such as I S 0 Class 4, and better. If monitoring is done in cleanrooms of poorer quality, thetime interval might be daily, weekly, monthly, three monthly or six monthly intervals, the interval being shorter as cleanroom classification becomes cleaner. Some further information is given in Chapter 15. Particle counts can be measured and recorded using the same criterion discussed in the previous paragraph. It should be noted that when particle counts are monitored, it is not expected that this should be done at the number or layout ofpositions laid down in I S 0 14644-1. Much fewer positions can be selected and they need not be distributed evenly around the cleanroom. Monitoring positions should be selected that are important to production e.g. close to wherethe product is exposed to contamination.

Acknowledgements Table 9.2 is compiled from information given in I S 0 14644-2 and reproduced by permission of the British Standards Institution.

10 Measurement of Air Quantities and Pressure Differences A cleanroom must have sufficient clean air supplied to dilute and remove theairbornecontaminationgeneratedwithintheroom.Inaturbulently ventilated cleanroom its cleanliness classification is directly related to the air supply; the more air supplied in a given time, the cleaner the room. Ina unidirectional cleanroom, the cleanroom classification is dependent on the air supply velocity. These volumes and velocities will have been decided at the design stage. It will therefore be necessary at the initial testing of the design, and at regular intervals throughout the cleanroom’s life, to measure and show that the air quantities are correct. To ensure that the air in a cleanroom always moves from clean to lessclean areas, a positive pressure difference between the areas will have to be set up. This is normally done when the correct air supply and extract volumes are set up, i.e. the air conditioning plant is balanced. This is discussed in Section 5.1.4 of this book.

10.1 Air Quantities Specialist firms usually carry out the measurement and adjustment of the airsupplyand extract volumeswhenthecleanroom is commissioned. However, simple tests can be used to verify that these air flow quantities continue to be maintained.Severaltypes of instruments can be usedto

124

Technolopy

Cleanroom

measure air quantities. Those commonly used in cleanrooms fall into the following groups: 0 0

hoods for measuring air supply volumes; anemometers for measuring air velocities.

In turbulently ventilated rooms, the supply and extract air volumes can be measured within the air conditioning ducts. Specialist firms using instruments such as a Pitot-static tube normally do this. The Pitot-static tube is inserted into the air duct and used to measure the velocities across the duct; the air supply volumes can then be calculated. However, it is also common to measure these air volumes from within the cleanroom.

10.l.l Measuring air quantitiesfrom within a cleanroom If the room air is supplied through a terminal air filter, without an air diffuser, then the air supply can be determined by use of an anemometer at the filter face. If the average velocity is found, then the air volume is calculated by multiplying that velocity by the area of the filter. However, because of the non-uniformity of the air velocity across the filter and at the edge of the filter, the average velocity is difficult to determine; it is therefore difficult to accurately measure the air supply volume. When air supply diffusers are used, the unevenness of the throw of air from around the diffusers, and hence the air velocities, make it almost impossible to measure the correct air volume. Similar problems occur at extract grilles, but the air velocity is more even and the use of an anemometer will give reasonable readings. It is best to use a hood similar to the type shown in the Figure 10.1 to measure the air supply volumes. The hood is lifted up to the ceiling and encloses the air supply diffuser. The supply air is then gathered together and an average velocity, and hence the volume per unit time, measured at the exit of the hood. This method overcomes the problems discussed in the previous two paragraphs.

Air QuantitiesDifferences and Pressure

125

x

Figure 10.1 Flow measuring hood

IO. l.2 Anemometers Anemometers are used to measure the velocity of the air being supplied from a high efficiency filter used in unidirectional flow. The anemometer has to be far enough away from the filter to allow the unevenness of the air coming from the filter to become more uniform. A distance of about 30cm (12 inches) from the filter isabout correct. 10.1.2.1 Vane anemometer These instruments measure velocity and work on the principle of air turning a vane, each turn usually being measured electronically and the frequency of impulses converted into a velocity. An example of a vane anemometer is shown in Figure 10.2. If the ve.locity to be measured is lessthan about 0.2 m / s (40 Wmin), the mechanical

Cleanroom Technology

126

friction insome anemometers may affect the turning of the vane. Some vane anemometers can average thevelocity over an extended time interval. This is a useful attribute, as the velocity of air from filters, and within the cleanroom space, fluctuates quite a bit. It can therefore be difficult to obtaina correct average reading without such a facility.

Figure 10.2 Vane anemometer

10.1.2.2 Thermal anemometers This type of anemometer uses the cooling effect of air passing through the head of the instrument to determine the air velocity. Different types exist, but a common type uses a bead thermistor, it’s cooling being in proportion to the velocity. An example of this type of instrument is shown in Figure

10.3. Low velocities can be measured with this type of apparatus and they are therefore suitable for use within cleanrooms. However, because of the air velocity fluctuations, average readings can be difficult to obtain accurately.

Air Quantities Differences and Pressure

127

Figure 10.3 ThermalAnemometer

10.2 Differential Pressure Tests It is necessary to ensure that air moves in a cleanroom suite from a clean to a less-clean area, and not vice-versa. Measurement of pressure is an indirect measurement of this, as air will flow from an area of high pressure to an area of lower pressure. The higher quality cleanrooms should therefore have a higher pressure than adjacent less-clean areas. The units of measurement used to register pressure differences are Pascals, although older units such as inch water gauge are sometimes used (12Pa = 0.05 inch water gauge). A pressure difference of 10 or 15 Pa is generally accepted as that which should be established between clean areas. 15 Pa is commonly used between a cleanroom and an unclassified room, and 10 Pa between two cleanrooms. Problems can occur when trying to achieve a pressure difference between areas connected by large openings, such as a supply tunnel. To achieve the suggested pressure drop it may be necessary to use very large air quantities through the tunnel, even where the area of the opening has been restricted, or to accept a lower pressure difference. To accept a lower

128

Technolopy

Cleanroom

pressure difference is perfectly reasonable as long as the primary requirement is achieved, i.e. the airflow is always in the correctdirection. It may, however, be difficult to convince everyone of the correctness of this argument, and it may be necessary to conform to cleanroom standards, which are normally stated in terms of pressure difference.

10.2.I Apparatusfor measuring pressure dlflerences A manometer capable of reading pressure differences in the range of 0-60 Pa (0-0.25 inch water) is required for measuring the pressure difference between rooms. This is usually an inclined manometer, magnehelic gauge, or electronic manometer. The inclined manometer works by pressure pushing a liquid up an inclined tube. The inclined gauge shown in Figure 10.4 measures small pressure changesin the inclined tube up to a pressure of about 60 Pa. After that pressure, the tube moves round to the vertical where the distance that the column of liquid moves, for a given pressure, becomes smaller. This then allows larger pressure difference to be measured and this type of gauge can also beused for applications, such as measuring a pressure drop over an air filter, where the pressure differences can be inthe 100 to 500 Pa range.

Figure 10.4 Inclinedmanometer

essure ces and Air Quantities

129

Figure 10.5 Magnehelic pressure gauge

The magnehelic gauge shown in Figure 10.5 works by the pressure acting on a diaphragm. This moves an indicating pointer, the movement being relayed through a magnetic linkage. A series of manometers are often mounted on the outside of the cleanroom so that the pressure differences can be easily seen and checked. Pressures can also be relayed electronically from manometers to a room management system.

10.2.2 Methods of checking pressure differences To check the pressure differences between areas, the air conditioning plant must be supplying and extracting the correct volumes of air and all doors in the cleanroom suite must be closed. If the pressure difference needs adjusting the air extract fromthe room must be reduced to increase the pressure, and opened to decrease it. If manometers are not permanently installed, a tube from a pressure gauge is passed under the door, or through an open by-pass grille ordamper into the adjacent area. It must be well clear of the door so that no pressure

130

Cleanroom Technology

is registered from air movement along the floor near the door. A reading of the pressure difference may then be taken. In some ventilation systems, the pressures within rooms are measured withrespect to onereferencepoint.When this type of system is being checked, the pressure difference acrossa doorway canbecalculatedby subtracting the tworeadings of the adjoining spaces.

Acknowledgements Figure 10.1 is reproduced by permission of TSI Inc. Figures 10.4 and 10.5 are reproduced by permission of Dwyer Ltd.

Air Movement Control Between and Within Cleanrooms 11.1 Cleanroom Containment Leak Testing To show that a cleanroom is working correctly, it is necessary to demonstrate that no contamination infiltrates into the cleanroom from dirtier adjacent areas. Airborne contamination can come from areas adjacent to the cleanroom through doors and hatches, as well as through holes and cracks in the walls, ceilings and other parts ofthe cleanroom fabric. If a cleanroom is pressurised correctly with respect to all adjacent areas, then air will flow out to areas of lower pressure and contamination will not enter the cleanroom. However, it is possible that adjacent areas such as air plenums or service ducts are at a higher pressure than the cleanroom and this may be overlooked. An example of such a problem is shown is Figure 11.1. It can beseen in this drawing that a supply air plenum of a vertical unidirectional flow system is at a higher pressure than the cleanroom. Contamination can then be pushed into the cleanroom at the (a) ceiling-to-wall interface, (b) filter and lighting housings-to-ceiling interfaces, (c) ceiling-to-column interface, and (d) through the cladding of the ceilingsupport pillars. Other infiltration problems are associated with service plenums and the entry of services into the cleanroom. For example, electrical sockets and switches, and other types of services providers, can be linked by conduits and ducts to dirty areas that are ata higher pressure than the cleanroom.

132

Technology

A B C D

Cleanroom

-

ceiling-to-wallinterface ceiling-to-filterhousinginterface ceiling-to-colum n c l a d d i n gi n t e r f a c e c o l u m nc l a d d i n g

Figure 11.1 Infiltration problems with an air supply plenum

These problems areparticularly difficult to foresee and control in a negatively pressurised containment room.

l l . ll . Methods of checking infiltration It is a relatively simple matter to check that air is flowing in the correct direction through an open door, or through the cracks around a closed door. Generating smoke and observing air movement does this. However, to ensure that there is no unwanted flow of airborne contamination into a cleanroom through cracks at the walls, ceiling, floor and filter housings, etc., it is necessary to check these cracks. This will normally be at the overlapping edges or butted joints, as well as any other placeswhere the cleanroom fabric is penetrated by, for example, service ductsor conduits. A test dust or smoke can be introduced into the areas where the containment arises and possible areas of penetration scanned with a particle counter. This is not an easy task. Where the containment originates from may be unknown, and it is often difficult to find the places to release test

Air Movement

133

smoke. In these cases, it should be sufficient to scan for particles, relying on the natural contamination that comes from the adjacent contaminated areas to show up any problem; if no particles show up in these circumstances the problem is unlikely to be serious. Containment leak testing should bedonein the cleanroom prior to handing it over to the user, or when major reconstruction work has been carried out. The IS0 cleanroom standard 14644-2 lists the ‘containment leak’ test as an ‘optional’ test and suggest a re-testing interval of two years (see Table 9.2).

11.2 Air Movement Control within a Cleanroom As part of the testing procedure to ensure that a cleanroom is working correctly, the air movement within the room should be checked. It is necessary to check that there is sufficient air movement within the room to either dilute, or remove, airborne contamination and hence prevent a build-up of contamination. In a turbulently ventilated cleanroom, air is supplied and mixed in a turbulent way. Good mixing shouldbe demonstrated in all parts of this type of cleanroom to ensure that contaminants will be removed. However, it is particularly important in critical areas, where the product is exposed to the risk of contamination, to demonstrate that good mixing is obtained. In a unidirectional flow, to ensure the cleanest conditions, critical areas should be supplied with air coming directly from the high efficiency filters. However, problems may be encountered becauseof: 0 0 0

0

heat rising from the machinery and disrupting the airflow; obstructions preventing the supply air getting to the critical area; obstructions, or the machinery shape, turning the unidirectional flow into turbulent flow; contamination being entrained into the clean air.

Visualising the airflow will demonstrate whether or not any of these problems exist and whether they are likely to cause an increase in contamination.

134

Cleanroom Technology

11.2.1 Air movement visualisation There are a number ofmethods that can be used to visualise the flow of the ‘air in a cleanroom. These can be grouped under the following headings: 1. streamers 2. smoke or particle streams 3. air velocity and direction measurement.

11.2.1.1 Streamers The types of streamers that are used to visualise airflow are threads or tapes. The best type are those which have a high surface-area-to-weight ratio, and can be easilyseen. Recording tapes of the type used in music cassettes can be used, as can loosely spun threads. A useful way of using streamers is to attach it onto the end of an anemometer; it can then be used to ascertain the direction of air when the velocity is being measured at a particular spot. Streamers can also be used by attaching a number of them onto a grid similar to that discussed in the Section 11.2.1.3.

Figure 11.2 Nylon thread streamer used with an anemometer

Air Movement

135

Streamers are useful to indicate the direction of airflow, but do not give an exact representation; because of their weight steamers do not flow with the air stream. This isa problem that increases as the airvelocity decreases. A horizontal flow of air with a velocity of about 0.5 m / s (100 Wmin) is required to get a typical streamer to stream at 45" to the horizontal and a velocity of about l d s (200 Wmin) for itto stream almost horizontal. 11.2.1.2 Smoke or particle streams There are a number of methods suitable for generating smoke or particle streams that are used to show the flow of air in cleanrooms. For example, the apparatus used to produce smoke fortesting filter integrity can be used. However, the use of oil smoke maynot be acceptable in some cleanrooms, as oil left on surfaces can be a contamination hazard. Water vapour is a contamination-free alternative and can be produced by different techniques such as from solid CO2 (dryice) or by nebulizing water. Figure 11.3 is a photograph of a nebulizing apparatus producing water vapour.

Figure 11.3 Fogger producing water vapour

Figure 11.4

Smoke from a puffer

Another technique for observing airflow is what isoften known as a ‘puffer and smoke tube’. The smoke tubes are about 2 cm in diameter and 10 cm long and made of glass. Within the tube is pumice stone is loaded with Titanium tetrachloride (TiCL). When required for use, both ends of the glass tube are broken off and one placed into an air puffer. By pressing the puffer, white smoke is expelled through the other end of the tube (Figure 1l .4). It ispossible to puff smokein the area tobe checked and observe the smoke movement. Titanium tetrachloride can also be purchased in bulk in bottles; bud swabs dipped into it will fume with smoke and can be used to observe air movements. Care must be taken with TiC14 as it produces acid that corrodes some surfaces and is likely to be harmful to sensitive machinery. It should not be used when products are exposed in the cleanroom. It is also necessary to ensure that the acid fumes do not harm the operator’s lungs.

Air Movement Control

137

Using one of the generating methods described above, the airflow in the room can be visualised and areas found where the air movement is poor. Single ‘puffs’, ‘streams’ or ‘multiple streams’ can do this. Sufficient information may be obtained by witnessing the air movement, but a permanent record can be preserved by the use of a video camera. It will be found in turbulently ventilated rooms that test streams will be quickly dispersed into the cleanroom. If this is so, it demonstrates that the room is working well. Areas where the smoke does not disperse quickly are areas where contamination can build up. These should not occur where the product is exposed to contamination. If necessary, the flow of air can be improved by adjusting the air supply diffuser blades, removing an obstruction, moving a machine, or by some similar solution. In most cleanrooms the critical area where the product is exposed to contamination will be within a unidirectional flow; this is where the room may be of a unidirectional flow type, or a unidirectional cabinet or workstation is used. In unidirectional flow, air moves in lines and the test stream is much easier to see than in turbulent flow. In unidirectional flow the air coming fiom the filters should, ideally, flow unimpeded to the critical area. However,problemsof the type discussed in section 11.2may occur. Whether one or more of these problems are likely to cause an unacceptable increase in contamination can be assessed by visualisation techniques. A useful method of visualisation uses a pipe of about 2.5 cm (1 inch) diameter with 2 to 3 mm diameter holes bored in line, about every 10 cm (4 inches). The pipe is set up on stands and supplied with a smoke stream fi-om a generator. The continuous smoke streams issuing out of the pipe holes gives good visualisation of the unidirectional airflow. Still pictures can be taken of the airflow, but because of the diffusion of the smoke they are generally not very clear. A video taken of the smoke movement gives the best representation of the airflow. The video pictures can be improved if the room lighting is switched off and the smoke highlighted with columns of light. 11.2.1.3 Air velocity and direction A permanent record of the airflow within the cleanroom can be obtained by measurement of the velocity and direction over a section of the room. Setting up a grid in the room helps with this. Stands the height of the room

138

Cleanroom Technology

should be used and strong thread, such as 4 pound nylon used by fishermen, strung acrossthe stands. The thread is marked at given intervals, e.g. 10 or 20 cm (4 inches or 8 inches), so that pointsare available for measuring air velocity and direction. Measurement can be done using a multidirectional anemometer that will give the air velocity either in the X and Y-axis, or in the X, Y and Z-axis. Theseanemometers can be expensive and a simple anemometerwith a streamer attached to give the air direction will give reasonable results, especially if the airflow is unidirectional and reasonably represented in two dimensions.

Figure 11.5 The direction and velocity of air coming from the supply filters to the exhaust of a partial-wall unidirectional workstation

Air Movement Control

139

Figure 1 1.5 shows a two dimensional representation of the velocity and direction of unidirectional airflow coming out from a unidirectional workstation. This system had a filter supply area 3m x 3m (10 ft x 10 ft) and walls that stopped 2m (6ft) from the floor, rather than coming down to near the floor. The air exhaust was in the ceiling around the outside of the canopy. Only half of the system is shown. The length of the arrows shown in the figure denotes the magnitude of the air velocity. This drawing showed that air reaches the table, and the air flow path to the exhaust prevents contamination from outside the workstation area being entrained into the clean area, and hence contaminating any work being carried out around the table.

11.3 Recovery Test Method The procedures described above are qualitative methods used to show that sufficient clean air gets to the critical areas. A quantitative approach can also be used. If test particles are introduced into an area being studied, the rate at which they are removed is dependent on the effectiveness of the airflow; the better the air movement and the more air that gets into the test area, the faster the reduction in the particle count. A burst of test particles should be introduced into the area to be tested, and after the particles have mixedwith their surroundings, the airborne particle count should be measured, and at regular intervals. A useful endpoint is one-hundredth of the original concentration, and the time taken to reach there can be used as an index of efficiency. However, this method is dependent on no particles being generated within, or introduced into, the test area; this must be demonstrated before starting the test

Acknowledgement Figure 1 1.3 is reproduced by permission of Clean Air Solutions.

12 Filter Installation Leak Testing As part of the cleanroom testing programme it is necessary to determine that the quality of air supplied to a cleanroom is suitable for the task being carried out in the room. High efficiency filters should efficiently remove the particles in the supply air. The filter efficiency will have been defined in the cleanroom design specification and will not bediscussedin this chapter (see Chapter 8 for information).

A - filter paper-to-case cementarea

C - gasket D - frame joints. B - filter paper (often at the paper fold)

Figure 12.1 Leakage areas in a high efficiency filter

High efficiency filters to be installed in the cleanroom will have been tested in the manufacturer’s factory and packed so they should arrive at the construction site undamaged. This is not always so. Damagemay also occur when the filters are unpacked and fitted into the filter housings. The typical fault areas of an installed filter are shown in Figure 12.1, and these will allowcontaminatedairto leak through the filter and into the cleanroom. There can be additional leakage problems associated with the housing into which a filter is fitted; this depends on how the filter is fitted. If the filter is inserted from the top down, i.e. fromabove the ceiling (Figure 12.2), then the gasket may leak. However, if the filter is inserted from the bottom up i.e. from the cleanroom,the gasket may leak but additional leaks can comefrom the filter casing (Figure 12.3); the problem of distinguishing between these leaks is discussed later.

Recirculated air

\

Ceiling beam

Gasket leaks

CLEANROOM

Figure 12.2 Gasket leaks from filters inserted down from ceiling

Testing143

Filter

Recirculated air

Particles from casing and gasket

CLEANROOM

Figure 12.3 Gasket and casing leaks from filter inserted up from cleanroom

A filter housing of the type shown in Figure 12.4 uses gel seals; these will prevent gasket leaks. However, they are more expensive. This type of housing is discussed in Section 8.6 , and is also shown in Figure 8.7. RECIRCULATED AIR

n

Ceiling beam

n

Knife'edge

on Itter frame

Figure 12.4 Filter-housing gel seal method

144

Technology

Cleanroom

Testing a high efficiency filter andits filter housing for leaks is normally done with an artificial test aerosol. This is generated by a dust or smoke generator and injected into the ductwork system so that there is a suitable concentration behind the high efficiency filter. Any problems are found by scanning thefilter system for test particles that leak through. High efficiency filters should have been supplied with the correct particle removal efficiency. A secondary function of the installation leak test is to check that the correct efficiency of filter has been supplied.

12.1 The Use of Aerosol Test Challenges Before discussing the choice of artificial test aerosols that are available to test filters, it is appropriate to consider two questions. Firstly, is it always necessary to carry out filter leakage tests in cleanrooms, and secondly, is an artificial test challenge necessary? It is fairly common in poorer quality cleanrooms [occasionally in I S 0 Class 7 (Class 10 000) and frequently in I S 0 Class 8 (Class 100 OOO)] not to carry out filter integrity tests. I S 0 Class 8 (Class 100 000) rooms may not use high efficiency filters in a terminal position in the supply duct, but bag-type filters positioned after the air conditioning plant; it will not then be possible to carry out a leak test of the type described in this chapter. It is also argued that if the air classification standard is achieved within the cleanroom then a small leakage of unfiltered air through the filter system has had little influence and isacceptable. This viewpoint is quite acceptable in turbulently ventilated rooms where the supply air is well mixed with the room air, and localised concentrations of contamination arising from a damaged filter are avoided. In unidirectional flow systems, especially in a cabinet or isolator where the distance from the filter to the critical area may be small, a hole in a faulty filter could give a unidirectional stream of contamination; this may give a localised and unacceptably high counts at the critical area. Unidirectional flow cleanrooms, and clean air devices that use unidirectional airflow, are therefore always tested for filter faults. In some cleanrooms, an artificial test challenge is not used to test the filters but the normal particle load in the supply air is used instead. It is argued that if the filter is tested for leaks with a particle counter (not a

Filter Testing

145

photometer)and no significant particle concentrations are detected, then there is no need to test the filter with abnormally high concentrations of particles. A reason given against this argument is that filter tests are normally carried out when the room is empty. The air recirculated from the empty room will therefore have fewer particles than the occupied room. However, it is possible to overcome this problem by using outside fresh air, as this has a high particle concentration. If the fresh air is filtered with high efficiency filters then these should be removed. The percentage of recirculated air should also be cut back as much as possible, so that the dilution of fresh air particles is minimised. Thisair may then give a sufficiently high concentration of particle challenge to find any filter leakage that will contribute to the particle count in the room. The choice as to whether or not to use an artificial test challenge may not be an open one, but determined by the requirement to conform to a cleanroom standard; this means that a test challenge is normally required.

12.2 Artificial Smoke and Particle Test Challenges The following artificial aerosols are available for testing filter installations in cleanrooms.

12.2.1 Cold-generated oils Di-octyl phthalate (DOP) is an oily liquid previously used to test filters. Because of potentially toxic effects, it is no longer used in many countries and similar oils, such as di-octylsebacate (DOS), Shell Ondina mineral oil, poly alpha olefin (PAO) or di-ethyl hexylsebacate (DEHS) are used. To create a cold-generated test aerosol, air is passed at high pressure through a nozzle designed for this purpose known as a Laskin nozzle. The air exits from the nozzle at high velocity and as it does so it shears the oil drawn from the reservoir. Fine particles of a mass median diameter of about 0.5 pm are ejected at a small positive pressure. These test particles should be introduced into the air supply at a position sufficiently removed from the filters to give good mixing and hence an evenconcentration across the back of the filter.

146

Cleanroom Technology

The output of one Laskin nozzle is relatively small (about 0.4g/min) and is only sufficient to test challenge a small volume ventilation system. The air volume that can be tested will depend on the concentration of the test challenge used, but a system supplying about 0.5 m3/s (1000 ft3/min) of air can be tested when the filter penetration is measured by a photometer. Multiple nozzle systems are therefore necessary for a larger volume system if a photometer is used. Another possibility is to use a single particle counter in place of a photometer. According to the IEST RP CC006, a concentration of 10 pgA of test aerosol will give a count of about 3 x 10" /m3 (109/ft3)of particles produced by a Laskin nozzle, and so a particle counter should be able to deal with most cleanrooms. Another alternative is to use of a photometer with a generator that produces larger quantities of test challenge by a hot generated method.

12.2.2 Hot generated smokes

Figure 12.5 Hot oil smoke generator

Filter Testing

147

Because of the difficulty of generating sufficient challenge from Laskin nozzles, hot-generated test smokesare often used. Thesealso have the advantage of requiring no air pumps; Laskin nozzles in a multi-nozzle format require an impractical amount of air for what must be a portable system. These thermal generators use an inert gas, such as CO,, to inject suitable oil into a heated evaporation chamber. The vaporised oil is then condensed as a fineaerosol of a mass median diameter of about 0.3 pm at the exit nozzle. Generators of the type shown in Figure 12.5 will produce around 10 to 50 g/min of aerosol, thisbeingsufficienttotest(inassociation with a photometer) an air ventilation system of upto about 40 m3/s (85 000 ft3/min).

12.2.3 Polystyrene latex spheres In some cleanroom situations, such as semiconductor manufacturing, inert test particles are specified. This is done to ensurethat there is no possibility of ‘outgassing’ of chemical products harmful to the process from any test aerosol left on the filter. Outside air has been used for this purpose,but the test particle of choice, at themoment, is Polystyrene Latex Spheres (PLSs). These are available in a wide range of monodispersed solutions from 0.1 to 1 pm in size, so that an appropriate size can be chosen. These solutionsare aerosolised andmeasured by a particle counter.

12.3 Apparatus for Measuring Smoke Penetration 12.3.l Photometer A typical photometer will draw 28 l/min (1 ft3/min) of airborne particles into it. These pass through a sample tube and across an area where light is concentrated. Particles refract the light andthis light passes through a collecting lens and onto a photomultipliertube where the light is converted into an electrical signal. Photometers usually measure a particle concentration ofbetween 0.0001 p8/1 and 100 pg/l. Such readings are dependent not only on the number of

148

Technolopy

Cleanroom

particles but their size, i.e. their muss. A typical photometer is shown in Figure 12.6. A photometer has an advantage over the single particle counter in that the concentration challenge can be measured, and this reading, by a flick of the switch, can then become the 100% reading. The instrument is then switched to an appropriate scale and when the leak penetration through the filter, e.g. 0.01% is exceeded this can be shown on the scale, or by an audible alarm.

Figure 12.6 A typicalphotometer

12.3.2 Single particle counters Particle counters of the type normally used to count and size particles in the air of cleanrooms can be used to carry out filter leak testing. However, the particle counter mustbe able to run in a continuous measuring mode. Particle counters are normally used to sample a volume of air and this is collected in a set time; some counters do not therefore sample continuously. If a particle counter is used to measure leaks in filters, the upstream particle challenge count is likely to be higher than the range of the instrument and

Filter Testing

149

can cause contamination problems in the instrument. A device will have to be purchased to dilute the upstream sample.

12.4 Methods of Testing Filters and Filter Housings 12.4.I Scanning methods Before starting to test theintegrity of filters, it willbe necessary to consider smoke alarms. Smoke leaking round the generator, especially ifitis brought into the cleanroom to test clean air devices can set off smoke alarms. The possibilities and consequences ofsmoke alarms going off should be considered. It is best to turn them off during the testperiod rather than suffer the embarrassment of the arrivalof the firebrigade, or a dousing from water sprinklers. The normal scanning methodis to use a probe together with a photometer, or single particle counter, to scan over the whole filter face. The perimeter of the filter then is scanned for leaks between the filter media and its filtercase, and the filter caseand its housing. The probe is normally held about 2.5 cm (l inch)fiomthefilter and thefilter scanned with overlapping strokes (Figure 12.7).

Figure 12.7 Scanning a filter

150

Technology

Cleanroom

The speed ofscan is important. If the probe passes slowly over a hole it will pick up more particles andfind more faults. A quick run over the filter will not be sufficient to pick up some faults, and this should be guarded against. A scan speed of not more than 5 c d s is reasonable but the IEST R P CC006 gives a method by which a more scientific approach can be used to ascertain the scan speed. If a photometer is used, the concentration of the challenge smoke is measured behind the filter and adjusted to a suitable concentration. This concentration will depend on the acceptable leakage. If it is 0.01% of the challenge then a concentration ofabout 10pg/l is reasonable. The photometer is then adjusted so that the upstream concentration becomes the 100% reading and thepercentage penetration is then read directly from the photometer scale. If a concentration of test challenge exceeds 0.01% of the contamination generatedbehind the filter, it is then considered as a leak. The most common leaks are around the periphery of the filter. They may come from the casing-to-housing seal, or when the filter is inserted from the cleanroom side, the casing joints as well (see Figures 12.2 and 12.3). In the former case, the filter will probably have to be removed and re-seated correctly. In the case of a room-inserted filter, it is difficult to distinguish between a casing and a casing-to-housing leak. It maybe necessary to check for casing leaks on a rig, re-fit, and check for housing leaks.

12.4.2 Testingfilters in unidirectionaljlow rooms The problem with checking thefilter bank in the ceiling of a unidirectional flow room isthatthe air filter areais so large that testing will take a considerableamountoftime. This maybe several days for a large semiconductor fabrication cleanroom. It may be usefbl to use methods that reduce the time. It is possible touse several particle sampler sensors of the type shown in Figure 13.6 in Chapter 13. By placing them on a motorised trolley with their inlet nozzles at a suitable height from the filter bank, and the correct distance apart, scanningcanbe done bymoving the trolley about theroom. The scanning time can therefore be substantially reduced.

Filter Testing

151

It is also possible toscaneach filter, and its casing, on a rig in the cleanroom and then carefully take the scanned filter, and place it into its housing in the ceiling. It is then only necessary to check the periphery of the filters for filter-to-housing leaks when the whole filter ceiling is in place and the ventilation system switched on.

12.4.3 Filter testing in conventionally ventilated room A conventionally ventilated room will generally be I S 0 Class 4 (Class lOOO), or poorer. The products manufactured within the room are therefore unlikely to be susceptible to oil out-gassing from the air filter, and oil smoke canbeused as a test challenge. Photometers are therefore most commonly used. To obtain good mixing, the test smoke should be injected well up the ductwork system away from the filter. Introducing it into the ventilation plant at a point before the fan will give good mixing. If there is any doubt as to the thoroughness of the mixing, its uniformity behind the filter should be checked. If an air diffuser is fitted after the filter, this should be removedto give access to the filter surface. Scanning ofthe filter is then carried out.

12.4.4 Repair of leaks If a leak is found to be coming from the filter media, it is often at the fold of the paper. This can be repaired on site with silicon mastic and it is generally accepted that a small area of the filter area canbe repaired. However, if no repairs are acceptable and imperfect filters mustbe replaced, then this should be agreed with the contractor at the quotation stage, as a quotation that includes the removal and replacement of filters is likely to be moreexpensive.

Acknowledgement Figures 12.5 and 12.6 are reproduced by permission of Steptech Instrument Services.

13 Airborne Particle Counts The most important test used to ensure a cleanroom is working correctly is a count of the airborne particles. Before proceeding with this count, the tests described in Chapters 9 to 12 should have been carried out on the following; the air supply volume, the pressure differences, the air movement within and between cleanrooms, and the filter integrity. These should all have been demonstrated to be satisfactory. It is then necessary, as a final test, to show that the airborne particle concentration does not exceed the particle class limit in the agreed occupancy state, or states.

13.1 Airborne Particle Counters An instrument known as a ‘particle counter’ is used to countand size particles in the air of a cleanroom. This is often called a ‘single particle counter’ to distinguish it from a photometer used to test filter installation leakage. A particle counter both counts and sizes particles in the air, whereas a photometer simply measures the mass of particles. For the sake of simplicity, the former instrument is called in this chapter a ‘particle counter’. A particle counter is an essential tool for testing and running cleanrooms. Goodsecondhandmodels are often available at a modest price, so that no cleanroom should be without one. Figure 13.1 shows a typical particle counter. Particle counters of this type, size particles in the range of 0.3-10 pm. Airborne particle counters will normally sample 28 l/min (1 ft3/min) of air and are available in models that size particles down to either 0.3 pm or 0.5 pm. Some high-sensitivity models can count down to about 0.1pm, but often with a smaller airsampling volume.

154

Technolopy

Cleanroom

Figure 13.1 Airborneparticlecounter

Figure 13.2 Hand-held particle counter

Particle Sampling

155

It is possible to purchase hand-held models of the type shown in Figure 13.2.Because of theamount of electricalpower required, hand-held models may only sample 2.8 Vmin (0.1fi3/min) of air and size down to 0.5

P . Figure 13.3 shows howa particle counter works. It uses a photodiode to sense light scattered by single particles passing through a beam of light in a sensing zone. The light source is typically a laser diode or, for greater sensitivity, a HeNe laser. The scattered light is concentrated by a lens system and converted by the photodiode into electrical pulses, their amplitude being in proportion to the particle size. Thus, the size of particle can be measured. Photodiodd

Laserdiode

Collection O p l I

Figure 13.3 Detection method used in a particle counter

The instrument can also count thenumber of pulses produced by the photodiode, and hence the number of particles is ascertained. Particles are normally counted on a ‘equal to and greater’ size basis, and all particles equal and greater to a given size are counted. This method of measurement is the same as specified in the cleanroom standards.

156

Technology

Cleanroom

13.2 Continuous Monitoring Apparatus for Airborne Particles In high quality cleanrooms, where the product is very susceptible to airborne particle contamination, continuousmonitoring of the air is used to checkfordeviations from the required airborne particle cleanliness. However, in lesser quality cleanrooms it is not necessary to sample continuously; a technician moving a particle counter about the cleanroom can carry out the testing. However, the technician’s time is expensive, and theirpresenceadds to the airborne contaminationin the room.It is sometimes better to continuously monitor the particle count. There are two main methods of continuous sampling. These are often called ‘sequential’ and ‘simultaneous’. In a sequential monitoring system, as shown in Figure 13.4, theroomisfittedwithsamplingtubes and a sampleofair is taken fromeachsampling point in turn. This air is transported through sampling tubes, via a manifold, to a particle counter, where the particles are counted. To add to the efficiency of the operation, the results are usually analysed. The simultaneous monitoring system, of the type shown in Figure 13.5, uses many small sensors to continuously size and count particles in the air at various pointsof the room. Manifold control

J

Pump sample air

Figure 13.4 Sequentialmonitoringsystem

nsors

Particle

157

Particle

Figure 13.5 Simultaneousmonitoring system

Figure 13.6 shows a typical sensor, its size being compared to a pencil. Information on the number and size of airborne particles measured by sensors is transmitted by electrical signals through a cable to a computer where they are analysed.

Figure 13.6 Sensor used in simultaneous sampling

Both monitoring systems use software packages to analysethe results. These can establish the overall average count in the room of various particle sizes, or calculate average counts at each position in the room.

158 They can alsoregister any results that are greater than an ‘alert’ or ‘action’ value set into the computer. Other information can alsobe made available. It would appear that the simultaneous monitoringsystem is the best system, as air is continuously sampled at the chosen sampling places and no high counts missed. However, it is also the most expensive system. The sequential method depositsparticles on the inner surfaces of the tubing that runs to the particle sampler, as well as within the manifold. However, these losses on the inner tube surfaces can be minimised if care is taken in the design of the system. If small particles (I 5 pm) are measured, the losses causedby deposition are small and usually acceptable; itis, after all, increases in particle counts that are sought rather than absolute values.

13.3 Particle Counting in Different Occupancy States One of the final tasks that must be carried out, prior to hand-over of the cleanroom tothe user, is the measurementof the airborne particle concentration. This is done to ensure that the count is within the standards set down atthe design stage. The airborne contamination in a cleanroom can be measured in three occupancy states. These are defined in I S 0 14664-1 as: 0

0

0

As built: complete and ready for operation, with all services connected and functional, but without equipment or operating personnel in the facility; At rest: complete,withall services functioning andwithequipment installed and operable or operating, as specified, but without operating personnel in the facility; Operational: in normal operation, with all services functioning and with equipment and personnel, if applicable, present and performing their normal workfunctions in the facility.

There can often be a considerable time delaybetween the cleanroom being completed by the building contractor and products being manufactured in the room. However, the contractor will wish to be paid for building the cleanroom and it is common practice to check that the room in its ‘as-built’

Particle Sampling

159

condition is satisfactory, and if it is, to pay all or most of the fee. The problem with checking the ‘as-built’ condition is that as there is no equipment working, nor personnel in the room, there is no generation of airborne particles. Thus, the airborne particle concentration can be very close to that of the filtered air supply. In practice, one or more people are required to test the roomand they will increase the particle count. However, the particle count will be much lower than when the room is ‘operational’. It will be tothe advantage of the cleanroom contractor to havethe class limits confirmedin the ‘as built’ occupancy state. The ‘as built’ state should have the lowest count of all the occupancy states, and this can be tested as soon as the room is ready. If the occupancy state has not been specified in the building contract there may be problems. The user may wish the cleanroom to perform satisfactorily in the occupied state, whereas the contractor may consider the room gives the correct class, albeit in the ‘at rest’ state. It should therefore be made clear in the building contract what occupancy state should apply. If a cleanroom has been designed properly and the cleanroom tested whenempty,i.e. in the ‘as-built’ state then there is a ‘rule of thumb’ assumption that canbe applied. This is that the ‘as built’ room will be about one class of cleanliness cleaner than when ‘operational’. This is not always correct, but it should be possible, by the use of some additional tests in the ‘as-built’ state, to predict how likely it is to conform to the class limit in either the ‘at-rest’ or ‘operational’ state. The important confirmatory tests are the quality and quantity of air supplied. Because of the directed airflow in a unidirectional system, the correct standards are likely to be achieved if the filters have no particles by-passing them, and the air velocities are correct. In a turbulently ventilated room, the achievement of the correct standard in its ‘operational’ state is less certain, as it is dependant on the air supply volume being sufficient to dilute the contamination dispersed from machines and people. However, this should not be a problem if an experienced designer is used. It is more normal to find that the designer over-designs and the cleanroom ends up cleaner than expected. After the contractor has handed over the cleanroom, the equipment will be installed andcommissioned and, finally, production will start. The

160

Technology

Cleanroom

particle contamination can then be measured at the ‘operational’ state. The ‘operational’ condition is the most relevant condition to be measured, as it reflects the actual contamination when the manufacturing area is working; this condition is also likely to give the highest particle count.

13.4 Measurement of Particle Concentrations (IS0 14644-1) The standard of a cleanroom is defined by the concentration of airborne particles, at a given size or sizes, that is not to be exceeded in a given occupancy state. These class limits are calculated by use of Equation 3.1 in Section 3.4 of this book. Some typical class limits for various particle sizes are given in Table 3.2, and also in Figure 3.2 in Chapter 3. To classify a cleanroom, it is necessary to take sufficient samples of air to have confidence that the airborne particle concentration of the room is within the limits set by the standards. The number of sampling locations must reflect the size of the room and its cleanliness. The larger and cleaner the room, the more sampling locations that must be used. The air sample must also beof a sufficiently large volume to give confidence in the results. The methods for (a) selection of the number of sampling locations and (b) determining the minimum air volume are laid down in IS0 146441, and explained below. The acceptance criteria that mustbemet for a cleanroom to achieve a given classification are given in the IS0 14644-1 and described below. Similar methods are used within the Federal Standard 209 E, and where these deviate from the I S 0 method, it is pointed out. However, anyone wishing to test a cleanroom must purchase the relevant standards (see Section 4.2.1.3 for information.)

13.4.l Sample locations and number I S 0 standard 14644-1 gives a formula by which the minimum number of locations can be calculated. This is as follows: N, = d A

(13.1)

Particle Sampling

161

where, N, is the minimum number of sampling locations (rounded up to a whole number) and A is the area of the cleanroom, or clean air controlled space, in m*. The I S 0 standard requires that the samples are evenly distributed around the cleanroom and placed at a height where the work is carried out. The method outlined in Federal Standard 209 E for calculating the number of sampling locations are substantially different from the I S 0 standard. These calculations depend on whether the cleanroom is unidirectional or non-unidirectional. To obtain fuller information, Federal Standard 209 E should be consulted. If the method given in Federal Standard 209 E is used it will give a larger number of sample locations than that suggested in the I S 0 14644-1 standard. Federal Standard 209 E is,in my opinion, overgenerous and the IS0 requirements are more appropriate.

13.4.2 Airborne sampling volume It is necessary to determine the minimum volume of air to be sampled at each location. Because there are fewer particles in cleaner rooms, a larger air sample will be required to be confident that the results are within particle class limits given in the standards. Both the I S 0 14644-1and Federal Standard 209 E standards require that the air volume should be large enough to count 20 particles of the largest particle size specified, if the concentration was at the class limit being considered. The following formula is used to calculate the minimum volume:

v = -20x C

1000

where, V is the minimum single sample volume per location, expressed in litres. C is the class limit (number of particles/m3 ) for the largest considered particle size specified for the relevant class. 20 is the defined number of particles that could be counted if the particle concentration were at the class limit.

162

Technology

Cleanroom

One or moresamplescanbe taken at each location. Thevolume sampled at each location should be at least two litres, and the minimum sample time should be at least one minute.

13.4.3 Acceptancecriteria The IS0 standard 14644-1 considers that a cleanroom has met the required classification if: 1. the average particle concentration ateach of the particle measuring locations falls below the class limit; 2.when the total number of locations sampled is less than 10, the calculated 95%UpperConfidence Limit (UCL)of the particle concentrations is below the class limit. The Federal Standard 209 E standard sets almost identical requirements.

13.5 Worked Example of I S 0 14644-1 Test Method To show the application of the IS0 14644-1 method, the following is taken as an example:

A cleanroom is 4m X 5m in floor size. It should comply with I S 0 Class 3 in the ‘as built’ condition ata particle size of 2 0.l pm. The calculations are as follows.

13.5.1 Number of locations The area of the cleanroom floor is4m x 5m. Therefore, the number of sampling locations = J4x5= 4.47 The minimum number of locations, rounded up to the nearest whole number, is therefore 5. Had the room been required to comply with FS 209 E a different calculation would have been needed. That calculation would depend on whether the room wasunidirectional or nonunidirectional.

163

Particle

13.5.2 Minimum air sampling volume The minimum volume (particle size

2 0.1 pm) =

20

x 1000

class limit for the given particle size

The class limit for a particle size of 2 0.1 pm in an IS0 Class 3 room is 1OOO/ m3.

:. Minimum volume

=

2o x 1000 = 20 litres 1000

Using a particle counter with a sampling rate of 28.3 1, i.e. l ft /min, a 42 second samplewill be required for each location. However, I S 0 146441 requires a minimum sample time of 1 minute.

13.5.3 Samplingresults Five locations must be sampled to fulfil the requirements laid down in the I S 0 14644-1 standard. A sampleset of results is given in Table 13.l . Table 13.1 Sampling Number Location 1 2

Particle counts at locations in the cleanroom

of particles Number

of particles

2 0.1 pm /28 litres

2 0.1 pm /m’

12

580

22

612

3 4

20

706

15

530

5

10

553

The results given are one minute samples and only one sample is given at each location, although averages of multiple samples or one long sample can be used. All of the results shown are below the class limit for the I S 0 Class 3 room, i.e. 1000/m3for particles 2 0.1 pm. The first part of the IS0 requirement is therefore satisfied. If the class limit is exceeded then the

Technology

164

Cleanroom

IS0 standard accepts that sampling can be performed at additional evenly distributed sampling locations. These results are definitive. As less than nine samples were taken in our sample, it is now necessary to show that the 95% UCL does not exceeded the class limit. This is done using the following method. Firstly, the ‘means of averages’ is calculated by the equation: Mean of the averages (M)=

Sum of individual averages Number of individual averages

The mean of averagesin this exampleis taken from the individual results, as only one sample has been taken at each location. The value can be calculated as follows: Mean of the averagesfor particles 2 0.1 vm (M) -

580 + 612 + 706 + 530 + 553

= 596

5

Using a mean of the averages equal to 596 the standard deviation of the means is now calculated as follows: Standard deviation (s.d.) -

(580 - 596)’

+ (612 - 596)’ + (706 - 596)’ + (530 - 596)’ + (553 - 596)’

\ -

5-1 256

+

256

+ 12100 + 4356+1849 4

= 69

where 5 in the denominator is the number of sample locations. The 95% UCL is now calculated.

165

Particle Sampling

Table 13.2 t-factor for 95% UCL Number of Locations

2

3

4

5

6

1-9

95% UCL factor

6.3

2.9

2.4

2. l

2.0

1.9

The ‘t-factors’ used in the calculation are given inTable 13.2. As the number of locations is 5, theUCL t-factor chosen from Table 13.2 is 2.1. The 95% UCL is now calculated using the equation:

c

95% UCL= M+ UCL factor x

L

s.d.] F

where, n = number of individual location averages

[

l:

95% UCL for particles 2 0.1 pm = 596 + 2.1 x -

= 661

From these calculations it may be seen that the calculated value of the 95% UCL is less than the required class limit of 1000. The cleanroom is therefore within the required class limit. Theabove set of results meet the second part ofthe IS0 14644-1 acceptance criterion, as the calculated 95% UCL is below the class limit. However, a large variation of the results, or an unusually low (or high) result may cause the 95% UCL to exceed the class limit. An example is five sampling locations that gave counts of 926, 958, 937, 963 and 214. The 95% UCL of these results can be calculated to be 1108 particles/m3. This cleanroom does not pass the acceptance criterion because of the one low result. If such a single ‘outlier’ is the cause of failure, and the reason can be found, then the I S 0 standard gives a method to treat and correct this problem. Such reasons are typically a mistake made during the sampling, or a sample point directly under a jet of clean air comingfroman air terminal. The way to avoid any 95% UCL problems is to always test more than nine points in the room; the time involved in additional sampling is often less than that required for the calculation of the 95% UCL.

166

Technology

Cleanroom

Acknowledgements Figure 13.1 is reproduced by permission of Particle Measuring Systems. Figures 13.4 and 13.5 have been redrawn from drawings supplied by Particle Measuring Systems. Figures 13.2 and 13.6 are reproduced by permission of Pacific Scientific Instruments. Bob Latimer of Pacific Scientific Instruments drew Figure 13.3. Extracts of IS0 14644-1 are reproduced by permission of the British Standards Institution.

Microbial Counts In bioclean rooms, such as those usedby pharmaceutical andmedical device manufacturers, the microbial population, as well as dust particles, have to be controlled. Peopleare normally the only source of microorganisms in a cleanroom. Testing for micro-organisms in the ‘as built’ or the ‘at rest’ operational conditions will therefore beof little value. However,when a cleanroom is fully operational, micro-organisms are continually dispersed from people in the room. It will therefore be necessary to monitor the cleanroom to demonstrate that a pre-determined concentration is not exceeded. It is common to sample the air and surfaces of the cleanroom, as well as the personnel workingin the cleanroom.Examplesof the microbial concentrations that should not be exceeded in a cleanroom are given in the EU GGMP (showninTable 3.4) the FDA ‘Guideline on Sterile Drug Products Produced by Aseptic Processing’; both are discussed in Section 3.5.

14.1 Microbial Sampling of the Air Several types of apparatus exist for counting micro-organisms in the air of cleanrooms. These samplers are sometimesknown as ‘volumetric’ air samplers because a givenvolume of air is sampled, thus distinguishing themfrom settle plate sampling, wheremicro-organisms are deposited, mainly by gravity, onto an agar plate. For a similar reason, this type of sampling is also known as ‘active’ sampling. Many types of samplers have been invented for sampling micro-organisms in the air. In cleanrooms, the most popular types are those that:

168

Cleanroom Technology

1. impact micro-organisms onto agar media; 2. remove micro-organisms by membrane filtration.

14.l.l Impaction onto agar. Impaction samplers commonly used in cleanrooms employ the following techniques to removemicro-organisms from the air: 0

0

inertialimpaction centrifugal forces.

Both these methodsimpact the microbe-carrying particles onto an agar surface. Agar is a jelly-type material with nutrients added to support microbial growth. Micro-organisms landing on a nutrient agar surface will multiply. If left at a suitable temperature, for sufficient time, the microorganisms will have multiplied sufficiently for a colony of a few millimetres diameter to be seen. Bacteria will normally be incubated for 48 hours at 30" C to 35" C; a further 72 hours at 20" C to 25" C will allow fungi togrow.Colonies are counted, andhence the number of microorganisms that have been deposited can be ascertained. 14.1.1.1 Inertialimpactionsamplers These samplers will typically sample 30 to 180 litres/min (approximately 1 ft/min to 6 ft/min) of air, although one brand of slit sampler can sample up to700litredmin(25f
Microbial

169

Figure 14.1 Airflow within a slit to agar sampler. Note that both the slit width and distance from the slit-to-agarwill be much smaller than shown.

be counted. Thus thenumber of microbe-carrying particles in a given volume of air can be determined. A sampler that draws air through multiple holes, i.e. a sieve, and impacts the microbe-canyingparticles onto an agar surface is shown inFigure 14.2. The outer sieve with its multiple holes has been removed to show a dish containing agar onto which the microbe containing particles are impacted.

170

Technology

Cleanroom

14.1.1.2 Centrifugal air samplers An example of a centrifugal sampler is shown inFigure 14.3. In this type of sampler, the airis drawn into the sampler by a rotating vane. This vane then throws, by centrifugal force, the microbe-carrying particles out of the air and onto an agar surface. The impaction surface is in the form of a plastic strip with rectangular recesses into which agar is dispensed. After sampling, the agar strip is removed from the sampler and incubated so that the microbe-containing particles can be ascertained.

Figure 143 RCS Centrifugalsampler 14.1.1.3Membrane filtration Another method used to sample micro-organisms in cleanroom air is membrane filtration. A membrane filter ismounted in a holder, a vacuum is applied and a known amountof air drawn through it. The microbe-carrying particles contained in the air passing through the membrane will be filtered out. One such system is shown in Figure 14.4. The membrane is removed from the filterholder and placed on top of an agar plate, incubated, and the micro-organisms that grow into colonies counted. Amembranefilter with a grid printed on the surface will assist in counting the micro-organisms. Filters made fromgelatine can also be used; the gelatine retains moisture, and it has been reported that this assists in preventing death of the micro-organisms by desiccation.

Figure 14.4 Membrane holder with filter

14.2 Microbial Deposition onto Surfaces 14.2.l Settle plate sampling In the previous section of this chapter, volumetric microbial sampling of the air in cleanrooms has been described. However, volumetric sampling of airborne micro-organisms is an indirect measurement of the likelihood of micro-organisms depositing on, or into, products manufactured in the cleanroom. The direct method isby settle plate sampling. As will be discussed in Section 19.2, micro-organisms in the air of occupied cleanrooms are usually found rafted on skin particles. These microbe-carrying particles are, in cleanroom terms, of a substantial size and have an average equivalent particle diameter of between about 10 pm to 30 pm. They can therefore deposit, by gravity, onto surfaces at an average rate of about l c d s . In settle plate sampling, Petri dishes containing agar medium are opened and exposed for a given period of time, thus allowing microbe-carrying particles to deposit onto them. Petri dishes, 90 mm in diameter (internal area 64 cm’) are frequently used but in high quality cleanrooms, with their

172

Technology

Cleanroom

attendant low airborne contamination, larger 140 mm (internal area 154 cm') Petri dishes are more appropriate. The number of microbe-carrying particles deposited on the agar surface of the plate over several hours of exposure is then ascertained. Four to five hours is a useful period, as it coincides with the time personnel are in the cleanroom; there is also little loss of micro-organisms caused by desiccation. Petri dishes must be about two-thirds to three-quarters full of agar to minimise desiccation. The microbial deposition rate can be reported as the number depositing ontothe area of a Petri dish in a given time; this rate can also be more scientifically reported as number deposited per hour, per 100 2 cm.

14.2.2 Calculation of the likely airborne contamination If the exposed area of a product and the time that it is exposed to airborne microbial contamination duringmanufacture is known, then it is possible to calculate the product's contamination rate. Using the number of microbecarrying particles deposited on a Petri dish in a given time and proportioning the areas and times of exposure, the contamination rate can be calculated from the following equation: Contamination rate

=

Settle plate count x area of product area of petri dish

A

time product exposed time settle plates exposed

Example: A 14cm Petri dish (154 cmz area) is laid close to where containers are filled and the microbial count on the settle plate after four hours of exposure was 3. The number of micro-organisms likely to deposit into the container of a neck area of l cm',when they are open during filling, foran average of 10 minutes is therefore: 1

3x-x--

154

lo

60x4

- 0.0008

(8 containers in 10 000)

Microbial

173

14.3 Microbial Surface Sampling Several methods are available for microbial surface sampling, but two are commonly used in cleanrooms. These are contact sampling and swabbing.

14.3.1 Contact surface sampling Contact plates and strips are usedwhen the cleanroom surface to be sampled is relatively flat. If plates are used, then RODAC (Replicate Organisms Detection And Counting) dishes of the type shown in Figure 14.5 are used. These dishes are often 55 mm in diameter with the inner dish covered by a lid resting on a lip. Pouring 15.5 m1 to 16 ml of agar medium into the central chamber fills it and gives an agar meniscus that stands proud of the rim. The agar is rolled over the cleanroom surface to be sampled. Microorganisms will stick to the agar andwhen the dishis incubated for a suitable time and temperature, the micro-organisms will grow into colonies that can be counted. When disinfectants are used there is likely to be a residue left on the surface that is sampled. The residue may stop the growth of micro-organisms and chemicals that neutralise the action of disinfectants should be incorporated into the agar medium to prevent this.

Aaar

Figure 14.5 Contact plate

174

Cleanroom Technolopy

Agar contact strips of the type shown in Figure 14.6 are also used to sample surfaces. These strips are removed from their container and applied to the surface to be sampled. The micro-organisms stick to the agar surface and the number ascertained by incubation and counting the colonies that grow.

Microbial Sampling

175

Figure 14.7

Swabbing with a bud swab

14.4 Personnelsampling Personnel are theprimary source of micro-organisms in a cleanroom, and it may be necessary to monitor them to ensure that there is no unusually high dispensers of micro-organisms working within the cleanroom. It may also be necessary, when unusually high concentrations of micro-organisms are found in the air, surfaces, or within the product, to find the person who is the source. The methods commonly used are: Finger dabs. The person’s fingers tips, or their gloved hand, is pressed or wiped on an agar plate and the number of micro-organisms ascertained. Contact plates or strips. The person’s garments are sampled by pressing the plate or strip onto their clothing. This is best done as they come out of the cleanroom. Body box. If a person wearing normal indoor clothing exercises within a body box their dispersion rate of airborne micro-organisms can be ascertained. (See Section 19.6.1.)

176

Cleanroom Technology

Acknowledgements Figure 14.2 is reproducedby permission of International pbi. Figure 14.3 is reproduced by permission of Biotest.

15 Operating a Cleanroom: Contamination Control The initial chapters of this book describe how a cleanroom is designed and constructed. Further chapters describe the tests required to ascertain that a cleanroom performed correctly when new, and throughout its life. In the final seven chapters I shall discuss how cleanrooms should be operated to minimise the risk of contamination. This chapter introduces the topic by considering the sources and routes of contamination within a cleanroom and how to control these. To be able to control contamination in a cleanroom it is first of all necessary to assess the various risks. A number of systems exist for assessing risk during manufacturing, such as Fault Tree Analysis (FTA) and Failure Mode and EfSect Analysis (FMEA). These systems appear to have been written for electrical and mechanical systems but can be applied to all types of risks. Those who are expert in working with such systems will be able to apply them to contamination risks. However, the majority of cleanroom users will more easily understand the Hazard Analysis and Critical Control Point (HACCP) system. This was devised, and is now used extensively, to prevent contamination in the food production industry. However, the system needs some reinterpretation and modification for application to cleanrooms in general. HACCP has a seven-step approach, but this requires some additions and re-arrangement to make it more understandable to the cleanroom user. I suggest the following system:

178

Technology

Cleanroom

1. Identify the sources of contamination in the cleanroom. Construct a risk diagram, or diagrams, to show these sources and their routes of contamination. 2. Assess the importance of these sources and whether, or not, they are hazards that need to be controlled.

used to control these hazards. 3. Identify methods that can be 4. Determine valid sampling methods to monitor either the hazards, or

their control methods, or both. 5. Establish a monitoring schedulewith ‘alert’ and ‘action’ levelsand corrective measures to be taken, where appropriate, when these levels are exceeded. 6. Verify that the contamination control system is working effectively by reviewingtheproductrejectionrate,samplingresults and control methods and, where appropriate, modifying them.

7. Establish and maintain appropriate documentation. 8. Train the staff.

15.1 Step 1: Identification of Sources and Routes of Contamination 15.1.I Sources of contamination Examples of sources of contamination in a cleanroom are as follows: 0 0

0

0 0

dirty areas adjacent to the cleanroom unfilteredairsupply roomair surfaces people machines,as they work

Contamination

0

a 0

179

raw materials containers packaging.

Areas adjacent to the cleanroom are likely to be less-clean than the production cleanroom; the material airlock and clothing-change areas will be contaminated by the activities going on in these areas, and the contamination in the outside corridors and service plenums may not be controlled. The air supplied to a room, if not correctly filtered, is a source of contamination. Room air is alsoa source if it contains contamination dispersed into it from other sources, such as people and machines. The floor, walls, ceiling and other surfaces in the cleanroom are examples of surface sources, their contamination being mostly derived from personnel touching them, or contamination depositing from the air. These surfaces can also be sources of contamination if poor quality constructional componentsare used, which break up and disperse fibres, wood chips, plaster etc. Cleanroom clothing, gloves and masks are other surfaces that are contaminated either by the people wearing them or by other cleanroom surfaces. Personnel within the cleanroom can disperse contamination from the skin, mouth and clothing. This contamination can be transferred to the product through the air, or by contact with their hands or clothing. Machines are another source, as they can generate contamination by the movement of their constituent parts, or by generation by thermal, electrical or other means. Raw materials, containers and packaging that are brought in, or piped into the cleanroom, may be contaminated and should be considered as sources.

15.1.2 Airborne and contact routes of transfer As well as identifying the sources of contamination in a cleanroom, the routes of transfer must be considered. The two main routes are airborne and contact. Contamination can be dispersed into the air from all the main sources and transferred to the product. If the particles are small they can float off to other parts of the cleanroom. However, if they are large, like fibres, chips

180

Cleanroom Technology

or cuttings they will remain within a short distance from where they were generated, and fall directly into, or onto, the product. Contactroutes of contamination occur when machines, containers, packaging, raw materials, gloves, clothes, etc. come directly into contact with the product. Contact Contamination can occur in several ways; one example is when personnel handlea product and the contamination on their gloves is transferred onto the product andanother is when the product comes into contactwith dirty containers or packaging. Using information of the type discussed in this and the previous section, the sources and routes of transfer can be ascertained and a risk diagram constructed forany cleanroom. 15.l .3 Construction of a risk diagram

Construction of a ‘risk diagram’ is a good method of understanding how contamination arises from sourcesand then reaches the product. The way in which a product is contaminated is often poorly understood but, by constructing a risk diagram, a greater understanding will follow. The risk diagram should show possible sources of contamination, their main routes of transfer, and methods of controlling this transfer. It may be necessary to construct several diagrams where the process is complex, or where it is necessary to control different contaminants, e.g. particles, microbe-carrying particles and molecularcontamination. Figure 15.1 is an example of a risk diagram showing the main sources of bacterial and particle contamination in a typical cleanroom. It also includes the main routesof transfer of contamination and the means of controlling it. The transfer of contamination around the room can be very complicated as, in theory, everything in the cleanroom can be contaminated by everything else. However, in practice, it should only be necessary to consider the major ones. It is interesting to note the central role of air, which receives and transports the many types of contaminants in a cleanroom. The manufacturing process has been excluded from Figure 15.1. This is shown separately in Figure 15.2.

181

Contamination Control

l

7

AREAS ADJACENT to the CLEANROOM

j

Adhesive

' M a t s o r Floor:

l

l

I A if Filters

~

MACHINES, CONTAINERS and PACKAGING

I

Figure 15.1 Sources and routes of particle and microbial contamination in a cleanroom along with preventative measures

Cleanroom Technology

182

l 7Contact through operators

Production i m e t h o d *; I C l e a n i n go r f iml ter at ht ioodn* ;

~

~

Production j

: Cleaning

I

Machine design; Exhaust j ventilation; j Cleaning ~

-

r-

L.

-

/ i

I

PRODUCT

Figure 15.2 Sources and routes of control associated with process machinery.

* contamination of the raw materials, containers and packaging can be controlled by producing them in suitably clean conditions

15.2 Step 2: Assessment of the Importance of Hazards When all possible sources of contamination in the cleanroom, and their routes of transmission, have been identified, the next task is to carry out a risk assessment. This is also called hazard or risk analysis. It ascertains what sources of contamination are important, i.e. if they are a hazard and their relative importance,or degree of risk. It is often difficult to determine which contamination sources are the most hazardous. This is especially difficult if the cleanroom is new and not yet operational, as few useful monitoring results will have been collected. However lack of monitoring results should not prevent a preliminary assessment being made, as itwill be possible at a later stage (Step6) to return

183

Contamination

tothesetentativeconclusionsforareappraisaland, if necessary, make changes. To determine the likely importance of a hazard, I suggest the following method. Firstly, a set of variables known as risk factors should be determined. These are: the amount of contamination on, or in, the source that is available for transfer (risk factor A); the ease by which the contamination is dispersed or transferred (risk factor B); the proximity of the source to thecritical point where the product is exposed (risk factor C); how easily the contamination can pass through the controlmethod (risk factor D). Table 15.1 shows the risk factors and score values that can be used to assess the overall risk rating, or hazard, of each individual source. Each of these factors (A to D) should be assessed and given a score of 0 to 2. Table 15.1 Risk factors for assessing hazards Amount of contamination on, or in, a source (A) 0 = nil

Ease of dispersion, or transfer (B)

Proximity from critical area (C)

Penetration through control method (D)

0 = nil

0 = outside corridor

0.5 = very low

0.5 = very low

0.5 = air lock

1 = low

1 =low

1.5 = medium

1.5 = medium

2 = hiah

2 =hkh

1 = periphery of cleanroom 1.5 = general area of cleanroom 2 = critical area

0 = barrier protection 0.5 = very good control 1 = good control 1.5 = some control 2 =control no

184

Technology

Cleanroom

Using Equation (15.1) the four scores should be multiplied together to obtain a risk rating. Thiswill have a valueof 0 to 16. Risk rating

=A x B x C x D

(15.1)

A risk rating can therefore be obtained for each contamination source and this rating can be used to determine the importance of each source and whether it is a hazard to the product. If required, the risk rating can assigned a ‘low’, ‘medium’ or ‘high’ category. For example, a risk rating of less than 4 can be considered as ‘low’, between 4 and 12 as ‘medium’ and higher that 12 ‘high’. Experience with the system will help develop a useable system. This risk rating can then be used to help determine how much effort should be put into controlling each source. However, it shouldbe appreciated that this method should only be used to assist in assessing the risks. The quality of the information available as input and the inexact nature of the mathematical model means that it cannot give exactpredictions. Two examples of a risk assessment will demonstratethe general method. Example I: A risk assessment is required to answer the question‘how great a hazard are cleanroom walls’.Firstly, the ‘amount of contamination’ factor (A) should be assessed. As the amount of contamination on the walls is ‘low’, a score of l could be given. The ‘ease of dispersion or transfer’ (B) is likely to be ‘very low’ and given a score of 0.5. As the wall is at the periphery of the room, a value of l is given to the ‘proximity’ score (C). A score of l might be an appropriate score for the ‘control of the source’ (D) if the wall was cleaned frequently, 1.5 if it was cleaned irregularly and 2 if it was never cleaned. Thus, the overallhazard assessment score of between 0.5 and 1 would be obtained. This demonstrates that walls are not an important hazard. Example 2: The hands of a personhandling aproductareconsidered. Maximum scores of 2 and 2 could be given for the ‘amount of contamination’ (A) and ‘the ease of dispersion, or transfer’ (B), as hands have very large amounts of particles, bacteria and salts and these are easilytransferred when personnel handle the product. A maximum score of 2 could also be

Contamination

185

assigned to the ‘proximity from the critical area’. The overall hazard assessment score is now dependent on how the hand contamination is controlled. If no gloves are worn, a hazard score close to the maximum of 16 can be calculated from Equation (15.1). If gloves were worn, then depending on how likely they were to be punctured, an overall hazard score of about 8 would be obtained. The use of double gloves, or gauntlets in an isolator, would give either very good control, or barrier protection, this would reduce the overall hazard score to close to0. It can beseen from this example that hands are a high potential hazard and their control is important.

15.3 Step 3: Identification of Methods to Control Hazards When all the contamination hazards in the cleanroom have been identified and their degree of risk assessed, it is then necessary to review the methods available to control them. The importance of obtaining an effective control method should be related to the above risk assessment; the greater the risk, the more effective the control method should be. It is also necessary to show that the control method is effective. If it is not then either a more effective control method should be adopted or the control method applied to a different point or place. Figures 15.1 and 15.2 show methods that can be used to control the routes of spread of contamination. These are: 1 . HEPAor ULPA air filters canbe used to prevent any contaminants entering with the supply air. However, unfiltered air can pass through holes in damaged filters, or by-pass the filter owing to poor filter housing construction. 2. Airborne contamination from areas outside the cleanroom, e.g. outside corridors and service plenums, can be prevented from entering the cleanroom by ensuring that the air moves from the cleanroom outwards, i.e. from clean to less-clean. Air locks and, or, a cascade flow of air through the doorways will ensure this. The use of adhesive cleanroom mats and flooring, as well as the removal, or covering, of dirty

186

3.

4.

5.

6.

7.

Cleanroom Technology outdoor shoes prevents surface contamination being transferred into the cleanroom. Although cleanroom air is a transfer route, it is also a source. Such airborne sources of contamination can bereduced by the use of a conventional ventilation system to dilute it, a unidirectional ventilation system to sweep it away, or an isolator or minienvironment to provide a barrier. The possibility of transfer of contamination from the floors, walls and ceiling is minimised by cleaning, and any contamination that becomes airborne is controlledby ventilation. Peopledisperse contamination from their mouth, hair, clothing and skin. Cleanroom garments andgloves will minimise this dispersion and contamination that cannot be controlled (as well as that produced by their clothing) can be minimised by the ventilation system. Contamination from machines can be minimised by the design of the machine, or by the use of exhaust air systems to draw the contamination away. Cleaning cancontrol dirt on the machine. Raw materials used to make products, or from which products are assembled, as well as containers and packaging, should be made from materials that do not generate contamination. They should also be manufactured in an environment that ensures that they have minimal concentrations of contamination on, or within, them. They should be correctly wrapped to ensure that they are not contaminated during delivery and that when the packaging is removed, on entry, contamination does not occur. Materials that are not sufficiently clean will require to be cleaned or, if fluid, filtered.

15.4 Step 4: Sampling Methods to Monitor Hazards and Control Methods It will now be necessary to set limits to ensure that contamination of the manufacturing process is kept under control. If air is taken as an example, then there are well-established methods of measuring particles and microorganisms, and standards such as I S 0 14644-1 should be used to set limits. However, if personnel handling the product cause the hazard, and the con-

Contamination Control

187

trol measure is the wearing of gloves, monitoring could be by inspecting for punctures and tears in the gloves, or measurement of particles or microorganisms on the surfaces. The methods used to monitor hazards within a cleanroom and the frequency of sampling are discussed in previous chapters. Given in Table 15.2 are some well-known cleanroom hazards, their routes of transfer and control, and how to monitor them. Also given in the table is the section of this book where further information may be found. Table 15.2 Sources, routes of transfer and control and monitoring methods used in cleanrooms. Control method Hazard Monitoring Route methods Section reference Supply air

airborne

air filters

filter integrity test

chapter 12

Areas adjacent to the cleanroom

airborne

overpressure; air movement control

room pressure differential

10.2; 11.1

contact

cleanroom mats

mat inspection

17.2.1

airborne

ventilation

air supply rate or velocity counts of airborne particles counts of airborne micro-organisms control of airflow

10.1

various airborne dispersions

Floors, walls and other surfaces

contact

People

airborne

cleaning (and, where required, disinfection) cleanroom garments

chapter 13

14.1 11.2

surface counting of particles,

21.6

and micro-organisms

14.3

surface counts; inspection for tears; particle penetration testing

19.6

Technology

188

Cleanroom

gloves contact

Machines

Raw materials

Containers and packaging

inspection for punctures

20.2.4

surface contamination counts

20,2,4

airborne

ventilation

air extract rates and airflow patterns

10.1, 11.2

contact

design of machine; cleaning or disinfection

-

-

surface contamination

21.6

control of manufacturing of raw materials

particle and bacterial counts within, or on, the materials.

not discussed

cleaning if solid, or filtration if fluids

filtration systems

not discussed

sterilisation

sterilisation system

not discussed

control of their compositioncounts and on manufacturing environment sterilisation

particle and microbial surface

not discussed

sterilisation system

not discussed

mainly contact

mainly contact

Step 4 of the contamination control system outlined in Section 15.1, requires a ‘valid sampling method’. The term ‘validate’ can be defined as ‘ensuring that something is fit for the purpose, or works well in the situation in which it is being used’. In terms of monitoring, the following may require to be demonstrated:

0 0

0

collection efficiency of sampling instruments; calibration ofthe instruments; determination that the hazard is of sufficient importance to need to be monitored; determination that the sampling method used is the best available for directZy measuring the hazard, or its control method.

Contamination Control

189

The last two requirements are not always easy to determine but, if correctly done, they will ensure that the monitoring effortis not wasted.

15.5 Step 5: Establishing a Monitoring Schedule with Alert and Action Levels Some monitoringsystems arecontinuous,as is thecase with particle counting in high quality cleanrooms, but on the other hand, some inconsequential contamination sources, such as the ceiling,are not monitored. The frequency of monitoring will have to be determined for each hazard or control method, for each individual cleanroom. This should be set up with due regard to the importance of the hazard; the higher the risk, the more frequent the samplingshould be. It is also necessary to decide what corrective actions should be taken when the monitoring results show that the hazard is not under control. A useful approach here is to set ‘alert’ and ‘action’ conditions; these are also called ‘warning’ and ‘alarm’ levels. In a cleanroom, it will be normal to consider only upper limits and ignore the lower ones,as low contamination levels are not a hazard. The ‘alert’ level should be set to indicate that the contamination concentrations are higher than might be expected, but are still under control. Nothing will normally be done if the ‘alert’ level is exceeded, as this is a warning to be on the alert for future problems. However, several ‘alerts’ in a relatively short time might suggest that action is required. The ’action’ level should be set such that when it is exceeded there should be an investigation. An assessment should be made as to whether it is a spurious result caused by natural variation, a mistake in the collection of the results, or a real result. For those results that are considered ‘real’, there should be an investigation by a method that has been set down; this should assess whether or not the result is acceptable and,if not, what action is required to bring the situation under control. Analysing the monitoring results and setting ‘alert’ and ‘action’ levels is quite a complicated subject if a statistical approach is used. Knowledge of statistical techniques, especially the use of trend analysis and Shewhart and CUSUM charts is required;a discussion of these is outside the scopeof this book. However, a simple approach can be taken by choosing appropriate

190

Cleanroom Technology

numbers from the available data, or seeking advice from the suppliers the instrumentsused to monitor the contamination.

of

15.6 Step 6: Verification and Reappraisal of the System A method must now be set in place to check that the system has been cor-

rectly implemented. Its usefulness might be indicated by the rejection rate of the product; as long as this is satisfactory then the system could be considered to be working well. However, it is also possible at this time to attempt to reduce the rejection rate by introducing a further control method. Verification that the system is working well can also be carried out by measurement of the particle, or microbial, levels in samples of the final product. Simulation of the process, e.g. filling containers with microbiological medium and ascertaining the microbial contamination, is a method that is useful in some circumstances. It is also possible to verify the effectiveness of thecontrolmeasures by inspection and assessment of the monitoring results. We can now reassess the following: 1. the relative importanceof the hazards 2. the necessity and the methods for controlling the hazards 3. the effectiveness of the control methods 4. the correctness of the monitoring schedule 5. whether the ‘action’ and ‘alert’ levels should be lowered or raised.

15.7 Step 7: Documentation An effective contamination control system will document (1) the methods described in the preceding steps of this chapter, (2) the monitoring procedures, and (3) results from the monitoring. The first two groups should be regularly updated to incorporate changes. Regular reports should be issuedof an analysis of the monitoring results and any deviations from the expected results. When ‘action’ levels are exceeded these should be reported. The actions taken to correct the devia-

Contamination

191

tions, or the explanations as to why no action was necessary, should also be documented. ‘Alert’ levels can also be reported, particularly those with a multiple or unusual occurrence.

15.8 Step 8: Staff Training All efforts to control contamination will fail if the personnel working in the cleanroom do not understand how the room works, and how they should conduct themselves within the cleanroom to minimise contamination. They should be trained in these aspects of contamination, both when they first arrive at the cleanroom and at regular intervals throughout their careers. Suitable items for a syllabus can beselected from the index of this book.

16 Cleanroom Disciplines Cleanroom personnel are a important source of cleanroom contamination. Almost all micro-organisms found in a cleanroom come from personnel, and they are also a major source of particles and fibres. It is therefore necessary to ensure the minimum of contamination is generated and transferred by personnel activities. By observing certain disciplines, contamination of the product can be minimised.These arediscussed in this chapter. When a cleanroom is about to be opened, management is faced with the task of employing people to work in the room, and determining what disciplines personnel (including maintenanceand service technicians) should adhere to within the cleanroom. It is hoped that this chapter will assist in this task. It should be noted that products manufactured in a cleanroom vary in their sensitivity to contamination, and cleanroom disciplines should reflect this. The information given in this chapter are options from which the user can choose methodsthat best reflect the degree of risk associated with their cleanroom.

16.1 People Allowed into Cleanrooms People can, when walking, produce about 1 000 000 particles 2 0.5 pm and several thousand microbe-carrying particles per minute. The more people, the higher the dispersion within the cleanroom. It is therefore important that the minimum of people, i.e. only the essential personnel are allowed into cleanrooms, and management should ensure that this is so. Because many contamination problems are caused by lack of knowledge, only people trained to work in a cleanroom should be allowed within

194

Cleanroom Technolopy

the cleanroom. Personnel should therefore be formally trained in the various aspects of contamination control. Visitors should be discouraged and only allowed in under the control of a supervisor; if a cleanroom is designed with windows for visitors to look into the cleanroom, this will usually suffice. Special care should be taken with service andmaintenance technicians, and their tools and materials; this is discussed at the end of this chapter. Peoplewhoenter the cleanroomshould not disperse significantly greater amounts ofcontamination than the normal population. Given below are examples of conditionsthat can cause more contamination than normal, and may therefore be unacceptable. Acceptability will depend on the risk, e.g. whether micro-organisms are a hazard, and whether the product is highly susceptible to contamination or not. It will therefore be up to management to decidewhich conditions are important. The following suggestions contain criteria that can discriminate against some personnel. It should be ensured that any discrimination is neither illegal nor unfair. The list also contains a number of temporary conditions. These are included as they may be a reason for temporarily assigning personnel toa job outside thecleanroom. Skin conditions where unusually large amounts of skin cells are dispersed, such as dermatitis, sunburn or bad dandruff. Respiratory conditions such as coughing or sneezing caused by colds, flu or chronic lung disease. In a biocleanroom, it may be necessary to screen personnel for the carriage of micro-organisms that couldgrowin the productand cause spoilage ordisease. Their suitability for work in a cleanroom should be considered with respect to the susceptibility of the product to specific types ofmicrobial growth. People with allergic conditions, which cause sneezing, itching, scratching, or a running nose, may not be suitable for employment in a cleanroom. Sufferers from hay fever are likely to find relief in a cleanroom because the air filtration system will filter out the allergens responsible. Some people may be allergic to materials used in the cleanroom, such as (a) garments made from polyester, (b) plastic or latex gloves, (c) chemicals such as acids, solvents, cleaning agents and dis-

Disciplines

195

infectants, and (d) products manufactured in the room, e.g. antibiotics and hormones. Depending on the contamination risk within the cleanroom, some or all of the following suggestions should be brought to the attention of the staff so that contamination within the room may be minimised: Personnel should have a good level of personal hygiene. They should shower regularly and keep dandruff at bay. They should wash their hair after a haircut to prevent hair landing on the product. In the case of dry skin, they should use skin lotion to replace skin oil that is lacking; this should reduce dispersion. Materials such as cosmetics, talcum powder, hair sprays, nail polish, or similar materials are not normally allowed in a cleanrooms. Anything added on to the body should generally be considered a contaminant. Cosmetics are a particular problem in semiconductor manufacturing as they contain a large amount of inorganic ions such as titanium, iron, aluminium, calcium, barium, sodiumandmagnesium. In the photographic industry, iron and iodine ions give problems. Other industries, which do not have a problem with specific chemicals, may still experience problems as each application will deposit large numbers of particles (up to lo9 for particles 2 0.5 pm) on the skin. Some of these will detach in the cleanroom. Watchesand jewellery are normally not allowedin a cleanroom. If jewellery is allowed, it must be under the clothing and gloves. Rings can puncture gloves and harbour contamination under them. Personnel may be reluctant, for sentimental reasons, to remove their wedding or engagement rings. They may be allowed to keep them on if the skin under the rings, as well as the rings, is washed. Where the rings are liable to puncture the glove they should be taped over. Smokers are said to produce more particles from their mouth than the normal population and outgas chemicals from their body. It may be necessary to ensure that they have not smoked for several hours before entering the cleanroom. It has been reported that taking a drink of water before entering the cleanroom reduces the numberof particles given off from the mouth.

Cleanroom Technology

196

16.2 Personal Items Not Allowed into the Cleanroom. As a general rule, nothing should be allowed into the cleanroom that is not required for production within the room. However, it is up to the management of the cleanroom to decide what items could cause contamination of the product. Items that should be considered for inclusion in a list of prohibited items are: 0

0 0 0 0 0

0

food, drink, sweets and chewinggum cansor bottles smoking materials radios, CD players, Walkmans, cell phones, pagers, etc. newspapers, magazines, books and paper handkerchiefs pencilsanderasers wallets, purses and other similar items.

Given in Section 18.2 of this book is a list of materials that may be required for manufacturing, and be sources of contamination. Some of the items from that list may be added to the above list.

16.3 Disciplines within the Cleanroom Within a cleanroom,many rules-of-conduct mustbefollowed to ensure that products are not contaminated. The management must produce a set of written procedures suitable for their room. It may be useful to have these ‘does and don’ts’ posted in the change or production area. Commonly used procedures that may be adopted are given below. These procedures do not consider the choice of cleanroom garments, masks, gloves and similar clothing items. Information about items of attire is given in Chapter 19.

16.3.I Air transfer To ensure that air is not transferred from an area of high contamination to one of lowercontamination (e.g. the outside corridor to the production room) the following disciplines should be adhered to:

1. Personnel must always come in and out of the cleanroom through change areas. The change area is used not only to change clothing, but as a buffer zone between the outer dirty corridor and the inner clean production area. Personnel should not use any entrance, such as an emergency exit, which leads directly from the production area to the corridor; this will allow contamination to enter directly into the cleanroom, and their garments may alsobecome contaminated. 2. Doors should not be left open. If they are, air will be transferred between the two adjoining areas because of general air turbulence as well as air transfer caused by a temperature difference between the two areas(Figure 16.1).

Figure 16.1 Doors should not be leftopen

3. Doors should not be opened or closed quickly, or air will be pumped from one area to the other. 4. Doors usually open inwards into the production room and are held shut by the higher pressure. However, to aid the movement of personnel who are

Cleanroom Technology

198

canying materials, some doors open outwards. Doors should then be fitted with door-closing devices to ensure that the doors are kept closed, and shut slowly to reduce the air transfer (Figure 16.3). Doors without handles will assist in preventing contamination of gloves.

16.2 Door closing device may be used

5. When passing through the doors in an airlock, personnel should ensure the first door is closed before going through the next one. Electrical interlocks between entry and exit doors achieve this, but care must be taken to ensure that there is no danger in the case of ftre. Indicator lights, which show if the doors are shut, are also used. Pass-through hatches should be used in a similar way.

16.3.2 Personnelbehaviour The following suggestions should be considered to ensure that personnel do not contribute to thecontamination within the room: 1. Silly behaviour should not be allowed. The generation of contamination is proportional to activity (Figure 16.3). A motionless person can generate

Disciplines

199

about 100 000 particles 2 0.5 p d m i n . A person with head, arms and body moving can generate about 1 000 000 particles 2 0.5 p d m i n . A person who is walking can generate about 5 000 000 particles 2 0.5 p d m i n .

S ittin g quietly Particles shed per min. = 100,000

Moving Particles shed per min. = 1 m illio n

Walking Particles shed per min. = 5 m illio n

Figure 16.3 Particle dispersion in relation to movement

2. Personnel should position themselves correctly with respect to the product, so that contamination does not land on it (Figure 16.4). They should not lean over the product in such a way that particles, fibres or microbe-carrying particles, fall from personnel onto the product, If personnel are working in a flow of unidirectional air, they should make sure that they are not between the product and the source of the clean air, i.e. the air filter. If they are, a shower of particles could deposit on the product. Methods of working should be pre-planned to minimise this type of contamination. 3. Consideration must be given as to how products are moved or manipulated. ‘No-touch’ techniques should be devised to prevent contamination getting from the gloved hand onto the product. Although gloves are worn in cleanrooms, they are still likely to be a source of contamination (although a reduced one). An example of this ‘no touch’ technique is the use of long forceps rather than hands to grip materials (Figure 16.5).

200

Cleanroom Technology

Figure 16.4 Do not lean overand contaminate the product

Figure 16.5 Forceps reduce contact contamination

Each cleanroom should have its own ‘no-touch’ rules to ensure that the product is not contaminated. Shown in Figures 16.6-16.9 are examples of how silicon wafers can be handled in semiconductor areas. These photographs were staged, as it would not be normal practice in a microfabrication facility to handle a silicon wafer except by a vacuum wand, or by robotic means. Figure 16.6 shows thewafer being held by the ungloved hand with the thumbtouching the surface.

Figure 16.6 Handling with no gloves

Oil and skin particles would contaminate the wafer with catastrophic results. If the wafer is held around the edge of the wafer (Figure 16.7) then contamination is reduced, but can still get onto thesurface.

Figure 16.7 Handling at edge without gloves

202

Technology

Cleanroom

Use of a glove (Figure 16.8) will reduce contamination yet further, and this technique is stillused where the line widths are large and a lower yield acceptable.

Figure 16.8 Handling with gloved hand

Figure 16.9 Handling with vacuum wand

Figure 16.10 Do not support materials next to thebody 4. Personnel should not support material against their body (Figure 16.10).

Although they will be wearing cleanroom clothing, which is much cleaner than indoor or factory clothing, it is not contamination free. Particles, fibres and micro-organisms can betransferred onto the items carried. 5 . Personnel should not talk when working over the product, or spittle from the mouth will pass round the imperfect seal between the mask and the skin and contaminate the product (Figure 16.11). Talking, coughing or sneezing can release contamination from the mask surface. If personnel cough or sneeze, they must turn their head away from the product. Masks are often replaced after sneezing. Masks mustnot be worn below the nose but over the nose as large particles can be released from the nose when snorting.

204

Cleanroom Technology

Figure 16.11 Care should be taken to ensurethat mask i S used correctly

Figure 16.12 Do not touch work surfaces

6. It is generally not good practice for personnel to touch cleanroom surfaces. Although cleanroom surfaces are very much cleaner than those outside thecleanroom, its surfaces, and that of the machinery in the room, will have particles, fibres and bacteria on them. If personnel touch their garments or mask,they also will pick up contamination on their gloves, which may be transferred to the product. Hands grasped together in front of the personnel, in the style of a hospital surgeon, will help to ensure that they do not inadvertently touch surfaces. 7. Personal handkerchiefs should not be brought into cleanrooms (Figure 16.13). These are clearly a major source of contamination and will transfer particles and microbe-carrying particles into the air and onto gloves. Noses should not be blown inside a cleanroom. The change area may be an acceptable alternative. 8. Washing, or disinfection when required, of gloves during use should be considered. Glove washing can be used in cleanrooms where products are handled and there are particular difficulties in keeping gloves clean. For example, in aseptic pharmaceutical production areas, gloved hands are rinsed with a suitable disinfectant (70% ethanol or iso-propanol) at regular intervals and prior to starting a critical operation. Alcohols are particularly useful, as they do not leave a residue on the glove.

Figure 16.13 Do not use personal handkerchief

206

Technology

Cleanroom

16.3.3 Handling materials The following suggestions, which refer to the materials used in the cleanroom, should beconsidered: Cleanroomwipersthathavelow concentration of contamination should be used. The exact type of wiper that is selected will depend on the financial budget and what is being produced in the cleanroom. It will also be necessary to decide how often a wipe should be used before being discarded. Some additional information is given in Section 20.3.3. The movement of materialsbetween the inside and outside of a cleanroom should be minimised. Every time a product moves out of the cleanroom there is a high possibility of it being contaminated in the less-clean area, and this contamination being brought back when it reenters. It is best to store products in a suitable clean area within the cleanroom, or in an adjoining clean area. It is normal tofind that great care has been taken to ensure that a product is not contaminated during its manipulation stages. However, after that, it can often be forgotten and left out in the cleanroom to gather dust. Products thatare susceptible to contamination should therefore be kept in closed cabinets, containers, unidirectional flow benches, or isolators. If the airflow in the cleanroom is unidirectional, storage racks of the type that allow air to flow through are a good choice. Materials should not be left standing on the floor. Waste material shouldbe collected frequently into easily identified containers and removed frequently from the cleanroom. Cleanrooms should be correctly cleaned (and disinfected if required). This major topicis discussed in Chapter 2 1. The cleanroom must bekept neat and tidy. If it is not tidy, it cannot be kept clean.

16.4 Maintenance and Service Personnel Through lack of training or supervision, people who enter a cleanroom to maintain or service machinery can be a considerable hazard. The mainte-

Disciplines

207

nance technician, unless instructed otherwise, will apply the same techniques as they do outside the cleanroom. Service personnel from outside firms may be completely untrained incleanroom contamination control techniques. The following is a list of procedures that should be considered for maintenance and service personnel: Maintenanceand service technicians should only enter a cleanroom with permission. Maintenance and service technicians should be trained in cleanroom techniques, or closely supervised when they are within the cleanroom. Technicians mustwear the same, or equally efficient, cleanroom clothing as cleanroom personnel, and use the same techniques to change into cleanroom clothing when entering and exiting cleanrooms. They should never enter the cleanrooms (especially at weekends, or when no one elseis around) without changing into cleanroom clothing. Technicians should ensure they remove dirty boiler suits, etc. and wash their hands before changing into cleanroom clothing. Tools that are used routinely for maintaining the cleanroom should be cleaned (and sterilised, if required) and kept stored for sole used within the cleanroom. Too.ls should be made from materials that do not corrode. For example, stainless steel is much preferred to mild steel tools , which may rust. If a service engineer or contractor brings tools into the cleanroom (especially those from outside the cleanroom organisation), then they must be cleaned. A wipe-down with a cleanroom wiper moistened with isopropyl alcohol (often 70%, in water) is a suitable method. Only the tools or instruments needed within the room should be selected, decontaminated, and put into a cleanroom compatible bag or container. This has the advantage of leaving behind cases or briefcases, with their associated scraps of paper, fluff etc.,which are potential sources of contamination; these should not be allowed into the room. Spare parts or items, like fluorescent light tubes, whichhavewrappings, should have the wrappings removed outside the manufacturing area and the parts wiped down. Information on this topic is given in Sections 18.3 and 18.4.

208

Technology

Cleanroom

Written methods should be kept for each activity, so that contamination control techniques canbe incorporated within a specification. These should be adhered to. Any instructions or drawings onnon-cleanroompapermust not be taken into the cleanroom. They can be photocopied onto cleanroom paper, or laminated within plastic sheets, or placed in sealed plastic bags. Particle generating operations such as drilling holes, or repairing ceilings and floorsshould be isolated from the rest of the area. A localised extract or vacuum can also beused to removeany dust generated. Technicians should not bring any materials into a cleanroom that are given on a list of ‘contaminating material’, similar to that in the list in Section 18.1 of this book. Technicians must tidy up when they are finished and ensure that the area is then ‘cleanroom cleaned’ by a person with suitable knowledge. Only cleaning agents,materials and equipment that has been approved for use in the cleanroom should be used.

Acknowledgement I would like to thank Lynn Morrison for posing for the photographs contained within this chapter.

17 Entry and Exit of Personnel Peoplecandispersemillions of particlesandthousands of microbecarrying particles fi-om their skin and clothing. It is therefore necessary for personnel working in a cleanroom to change into clothing that minimises this dispersion. Cleanroom clothing is made from fabrics that do not break up and lint; they therefore disperse the minimum of fibres and particles. Cleanroom clothing also acts as a filter against particles dispersed from the person’s skin and their indoor,or factory, clothing. of The type of cleanroom clothing used varies according to the type cleanroom. In cleanrooms where contamination control is very important, personnel wear clothing that completely envelops them and prevent their contamination being dispersed, i.e. a coverall, hood, facemask, knee-length boots and gloves. In cleanrooms where contamination is not as important, less enveloping clothing such as asmock, cap and shoe covers may be quite sufficient. Information about cleanroom clothing is given in Chapter 19. Whatever the choice of clothing, garments will have to be donned prior to entering the cleanroom, and they should be put on in such a way that the outside of the clothing is not contaminated. This chapter describes typical methods. Some types of cleanroom garments are worn once before being thrown away; others are sent for cleaning and processing after being used once. However, garments are normally used more than once. It may therefore be necessary to devise a storage method to ensure that a minimum of contamination is deposited onto them. Possible methods are discussed at the end of this chapter.

210

Technology

Cleanroom

17.1 Prior to Arriving at the Cleanroom Poor personal cleanliness is not acceptable in a cleanroom. However it is not clear how often personnel should bathe or shower, there being little in the way of scientific investigations into this topic. Clearly a shower would be necessary if someone has just had a haircut and is likely to shed hair clippings. It is known that washing can remove the natural skin oils and, in some individuals, the dispersion of skin and skin bacteria can increase. People with dry skin may wish to use a skin lotion to replace the lost skin oils. Consideration should be given to whatclothingisbestwornbelow cleanroom garments. Clothing made from artificial fibres, such as polyester, are better than those made from wool and cotton, because synthetic fabrics disperse much fewer particles and fibres. Close-woven fabrics are also an advantage, as these are more effective in filtering and controlling the particles and microbe-canying particles dispersed from the skin. This type of problem will be overcome if personnel are issued with factory undergarments. These should be made from a fabric that does not lint, and it should effectively filter particles dispersed from the person. Personnel should consider whether applying cosmetics, hair spray, nail varnish, etc. at home is necessary, as these should be removed prior to entering the cleanroom. They should also consider what rings, watches and valuables they will bring to work, as they are likely to be removed and stored. These and other suggestions with regard to staff entering a cleanroom are discussed in Section 16.1.

17.2 Changing into Cleanroom Garments The best method of changing into cleanroom garments is one that minimises contamination getting onto the outside of the garments. One such method is described below. Some of the suggested procedures may be unnecessary in poorer classes of cleanrooms, and further procedures can be introducedin cleanrooms thatmanufacture products very susceptibleto contamination.Itshould also benotedthatalternatives to theproposed method are successfully used in existing cleanrooms, and these are quite

Entry Procedures for Personnel

21 1

acceptable as long as they give a levelof contamination control appropriate to the standard ofthe cleanroom. The design of clothing change areas is discussed in Chapter 5 where it is explained that the change area is normally divided into zones. These may be rooms, or rooms divided by crossover benches. Change areas can vary in design, but itis common to find them divided intothree zones: (1)

(2) (3)

Pre-change zone Changing zone Cleanroom entrance zone.

Personnel move throughthe zones in the following manner.

I 7.2.I . Approaching thepre-change zone

Figure 17.1 Cleanroomshoecleaner

212

Technology

Cleanroom

Before starting to change into cleanroom clothing, it is best that personnel blow their nose. It is impossible to do this correctly in a cleanroom, and if this is done it will save an unnecessary trip out of the cleanroom. They should also go to the toilet. If it is necessary to come outof the cleanroom to go to the toilet, it is likely to entail changing out and back into cleanroom clothing. Incleanroomswhereoutdoorshoes are notremoved, or effectively covered, shoe cleaners should be used. Cleanroom shoe cleaners are specially made to retain contamination dispersed from the shoe:use of one is illustrated in Figure 17.1.

Figure 17.2Dycemcleanroommat

Sticky cleanroom mats or flooring are often used in the approach to the changeroom.These are speciallymanufacturedforuseincleanrooms. There are two general types. One type is laminated from layers of thin adhesive plastic film and the other from a thick resilient adhesive plastic.

for Entry Procedures

213

Both work by removing dirt from the soles of footwear as personnel walk over them (see Figure 17.2). After a while they become soiled.In the case of the plastic film version,the topmost layer is peeled offto expose a fresh layer. In the case of the resilient plastic type the surfaceis washed. If a laminated matis used, shoes should be applied to a mat three times to ensure the removal of practically all of the footwear contamination. If the resilient-type cleanroom flooring is used it can cover a floor surface area large enough to ensure that sufficient steps are placed on it to ensure effective dirt removal. Thisis a minimum ofthree per foot i.e. six in all.

17.2.2 Pre-change zone Within the pre-change zonethe following tasks may be carried out: 1. Personnelshouldremovesufficient street or factory clothes to feel comfortable in the cleanroom. If the company provides dedicated clothing to wearunder the cleanroomgarments, then all street clothing should beremovedandreplacedwithfactory garments.

...

~i

~~

~

~

2. Watchesandringsshouldberemoved. They can harbour dirt, produce chemical and particle contamination, and are liabletoteargloves.Wedding rings that are smooth may be kept on if the ring(andunderthe ring) is kept clean. Rings that are not smooth can be taped over. Items such as cigarettes and lighters, wallets and other valuables should be securely stored.

Cleanroom Technolopv

214

L

1 L L

3. Remove cosmetics and, if required, applyasuitableskinmoisturiser.The composition of any moisturiser should be considered to ensure that nochemicals usedin the formulation cause contamination problems in the product being sposablebouffanthat, or met. This ensures that hair does not stick out fromunder the cleanroom

5 . Put on a beard cover,if appropriate. 6 . Put on a pairof disposable footwear coverings,or change into dedicated cleanroom shoes. 7. If a hand washing system is located in this areathenwash the hands, dry them and, if necessary, apply a suitable hand lotion. However, it is probably best if hands are washed within the change area just before the cleangarments are puton (see below). If gloves are used to put on cleanroom clothing, then hand washing can be done here. In bioclean areas,it will be nec-

Entry Procedures for Personnel

215

should stop atthe mat and put their footwear three times to the mat to make certain that itis clean and the minimum of contaminationis tracked intothe next zone.

I 7.2.3. Changing zone The garments used in the cleanroom are put on in this area. Several methods can be used but the following is suggested. This uses a method assumes that afacemask,hood, coverall and overboots are used, but it can be adapted for use with a cap, gown and overshoes. It requires that the garments are put on fromthe top down.

1. The garments to be worn are selected.Ifafreshgarment is used, then it should be checked for size and the packaging checked to ensure that it is free from tears and faulty heat seals. The packagingis then opened. 2. A facemask and hood (or cap)is put on. It appears to make little differencewhether the mask is put under, or over, the hood.Choose which method is the most comfortable. If a hood is put on, the hair mustbetucked in and the studs (snaps)or ties at the back of the hood adjustedfor comfort. 3. If a hand washing system is installed in this area then the hands should now be washed (and disinfected if required). This is possibly

216

Technology

Cleanroom

the best time for personnel to wash their handsas clean garments will now be handled and contaminated parts of the body, such as the hair and face, should not be touched again. 4. Temporaryglovesknown as ‘donninggloves’aresometimes used to prevent the outside of the cleanroomgarmentbeingcontaminated. Use of these gloves is confined to the higher quality of cleanroom.Theseshould, if required, be put on. 5. The coverall (or gown) should beremovedfrom its packaging andunfoldedwithouttouching the floor. It is sometimes possible to get the cleanroom laundry to fold the garment in a waythat will minimise both the chance of the garment touching the floor and the outside surface being contaminated bythe personnel’s hands. If this is not done, thenthe following can be considered. If a coverall is used, it should be removedfiom its packing and allowed to unfold without touching the floor.It should be unzipped and turnedso that the zip is to the side away from the person. There are now several methodsof putting on the garment to ensurethat it does not touch the floor. These areas follows: Thecoverallcanbegatheredtogetheratthe 4 cornersi.e.the two wrists and thetwo ankles. It should then be possible to put first one leg and then the other into the garment without the trouser legs touchingthe floor. 0 Thegarmentcanbeheld in the inside at waist level, someof the material gatheredupandonelegandthen the other put in to the trouser legs. The top of the coverall can then be slipped over the shoulders, or, 0

for

Entry Procedures

0

217

The left cuff and left zipper can be taken in the left hand and the right zipper and right cuff taken in the right hand. The coverall can then be gathered up at the waist and one leg placed intothe garment, and then the other leg placed intothe other garment leg. By releasing one cuff at a time, first one arm and then the other can be placed into the garment. The last twomethodswillwork better if the trouserlegs are folded back on themselves so that they are shorter and lesslikelytotouch the floor. The garmentshouldthenbe zipped all the way up to the top, ensuring that all of the hood (if used) is tucked under the collar. A mirror is useful at this stage. If the garmenthaspressstuds (snaps) at the ankles and wrists, then these shouldbe snapped shut.

17.2.4 Cleanroom entrance zone 1. If a crossover bench is available, it should be crossed over now. This bench is usedtodemarcatetheslightlysoiledchanging-zonefrom the cleaner entrance zone, and allows cleanroom footwear (overshoes or overboots) to be correctly put on. 2. Personnelshould sit on the bench.Onelegshould beraised, the cleanroom footwear put on, the leg transferred over the bench and placed on the floor of the entrance zone. Thenthe other leg should be raised, the cleanroom footwear put on and the leg taken over thebench.While still sitting on the bench, the legs of the cleanroom garment and the footwear

218

Technology

Cleanroom

should be adjusted for comfort and security. Personnel should now stand UP. 3. If required, protective goggles of the type shown in Figure 17.3 can be put on. These are used not only for safety reasons but to prevent eyelashes and eyebrow hair falling onto the product.

Figure 17.3 Protectivegoggles

4. The garments should be checked inafull-lengthmirrorto see that they are worn correctly. Check that the hood is tucked in and there are no gaps betweenit and the coverall (or gown). Check that no hair can be seen. 5. If donninggloveshavebeen usedtheycanbedispensedwith now. They can, however, be kept on andapair of cleanworking glovesputontop. Two pairs of gloves can be used as a precaution

for Entry Procedures

219

against punctures, although sensitivity of touch is lost. 6 . If deemed necessary, the hands can again be washed. Gloves can also be washed. In a biocleanroom it is beneficial to decontaminate the hands by applyinganalcoholsolutioncontainingaskindisinfectant.Apartfrom being more efficient,the use of an alcohol solution overcomes the problem of having a washhand basin in the room, with its attendant risk of microbial growth. 7. Lowparticle(and if required, sterile) working gloves should now beputon,without the outsideof them becoming contaminated. In somecleanrooms this task is left until the personnel is within the production cleanroom. If they are latex gloves, which are wrapped in pairs with the cuffsrolledback(in the style usedbysurgeons),then the gloves can be put on without being contaminated. In this case, the first glove is taken out of the exposed package by gripping the fold of the rolled-over cuff with the one hand and inserting the other hand into it. Two fingers of the gloved hand are then passed under the rolled-over cuff of the second glove and it is lifted from the package. The hand is then put into the second glove, the fingers being slotted intothe correct fingers of the glove, andthe cuff lifted overthe cuff of the cleanroom garment. It is now possible to pull back the cuff of the first glove, making surethat it is completely overthe garment’s cuff. 8. Most cleanroom gloves are not packed in a way that will allow gloves to be put on without contaminating the glove surface. These gloves must be gripped at the edge of the cuff and put on in a similar way to that described above. Gloves packed in pairs will be contaminated less than those packed in 50s or loos, as it is difficult to remove a glove from a large pack withoutcontaminating those that are left.Ifconsiderednecessary,the gloves can now be washed or disinfected. 9. Personnel may now proceed into the cleanroom. This may be over a cleanroom mat.

220

Cleanroom Technology

17.3 Exit Changing Procedures When leaving a cleanroom, personnel will either (i) discard all their garments and on re-entryuse a new setof garments (this is normally only employed in an aseptic pharmaceutical cleanroom), or (ii) discard their disposable items, such as masks and gloves, but reuse their coverall, smock, etc. on re-entry. If a complete change of clothing is required on re-entry, then the disposable items such as bouffant hats, gloves, facemask and disposable overshoes are placed in a container for disposal. If the remainder of the garments are not disposable then they shouldbe placed in a separate container for dispatch tothe cleanroom laundryfor processing. If the garments are to be used again on re-entry, they should be removed so that the outside of the garment is contaminated as little as possible. The cleanroom footwear should be removed, one at a time, at a crossover bench, as each leg is taken over the bench. The coverall should then be unzipped and removed usingthe hands within the garment to remove it over the shoulder and down to the waist. In a sitting position, one leg is now removed the garment. The empty arm and leg of the garment should be held so that they do not touch the floor. The other leg can now be removed. The facemask and hood can now be removed.

Entry Procedures for Personnel

22 1

Garments to be used again on re-entry should be stored to prevent contamination. This can be done in several ways, as follows: Each item of clothing can be rolled up. In the case of cleanroom footwear this should be done so that the dirty soles are to the outside. The footwear can now be placed in separate pigeon holes and the hood and coverall (or cap and gown) in another. If thought necessary, the items of clothing can be placed into bags before being put into the pigeon holes. The hood (or cap) can be attached to the outside of the coverall (or gown) by means of a snap (stud) and hung up, preferably in a cabinet. The cleanroom footwear can be placed at the bottom of the cabinet. It is best that their garments should not touch the wall, or each other. In higher grade cleanrooms, clothing is often hung up in unidirectional flow cabinets (see Figure 5.7 in Chapter 5), specifically designed to ensure that garments are not contaminated. Garment bags can be used. These will have separate pockets for the various clothing items and shouldbe regularly laundered.

Acknowledgements The cartoons used to illustrate this chapter are used the kind permissionof CleanRooms Magazine, a PennWell Publication. Figure 17.1 is reproduced by permission of Roger Diener of Analog Devices Inc. Figure 17.2 is reproducedbypermission of DycemLtd. Figure 17.3 isreproducedby Metron Technology.

18 Materials, Equipment and Machinery 18.1 Choice of Materials Materials used in cleanrooms must be selected with care to ensure that they do not contribute to the contamination in the room. Typical of materials used in a cleanroom are: Materials used in the manufacturing. In a pharmaceutical manufacturing area it might be containers and ingredients. In the microelectronics industry it might be silicon wafers and process chemicals; Packaging for the product. This could be, for example, glass or plastic bottles, plastic bags and pre-formed boxes; Process machinery and equipment; Tools used for the maintenance, calibration or repair of equipment and machinery; Clothing for personnel, such as suits, glovesand masks; Materials for cleaning, such as wipers and mops; Disposable items such as writing materials, labels and swabs. Depending on the products made in the cleanroom, contamination on materials can be:

0

particles micro-organisms chemicals

224

Technology

Cleanroom

electrostatic charge molecular outgassing. In almost all cleanrooms, particles and fibres will be a problem. Materials that break up easily or disperse particles when used in the manufacturing process should therefore be avoided. Materials that come into cleanrooms with particles or fibres on their surface should also be avoided. In bioclean roomsof the type usedin the healthcare and food industries, microorganisms are contaminants. In the semiconductor industry chemicals, both on the surface and outgassed, may deposit onto the surface of a semiconductor, and are a problem. Materials that are unable to continually conduct away any electrostatic chargemay cause difficulties in some cleanrooms if the charge builds up and discharges to an electrically sensitive product. A static charge may also attract particles to the material, and these can cause contamination problems. Materials used in cleanrooms for manufacturing should be chosen not only because they are suitable for manufacturing, but because of their noncontaminating properties. Materials and items that are required for production, but are clearly contamination sources, should be used only if essential, and only if these contamination control problems have been recognised and alternative steps considered andrejected. Depending on the susceptibility of the product to Contamination, some, or all, of the following list will be prohibited because of contamination problems: abrasives orpowders; aerosol-producing cans orbottles; items made from wood, rubber, paper, leather, wool, cotton and other naturally occurring materials that break up easily; items made from mild steel, or other materials that rust, corrode or oxidise; items that cause problems when machined or processed, e.g. they may smoke or break up; paper not manufactured for use in cleanrooms. If ordinary paper must be used then it should be sealed in plastic envelopes or laminated between plastic films;

Equipment Materials,

0 0

0 0

0

225

pencils and erasers; writing implementssuch as fibre-tipped pens that could scratch paper, or whose ink contains contaminating chemicals; paper correcting fluid; personal items listed in Section 16.2 should not be brought in by cleanroom personnel; disposable items such as swabs, tapes and labels that are not cleanroom compatible.

Items used for cleaning the cleanroom such as wipers, mops and cleaning solutions should be selected from a range that have been specially manufactured for use in cleanrooms. This is discussed in Section 20.3. Similarly, maintenance and test tools, such as spanners and screwdrivers, should be selected to minimise contamination, and should be kept clean.

18.2 Items Supplied from Outside Manufacturing Sources Items can arrive in a cleanroom badly contaminated if they come from a supplier who is not knowledgeable or concerned about cleanroom requirements. This can, in some instances, be the single most important cause of contamination of products, and steps may have to be devised to overcome the problem. Items supplied for use in a cleanroom should ideally be manufactured in a cleanroom of the same standard as the cleanroom they are used. They should also beproduced using similar cleanroom contamination control techniques. If items cannot be delivered with a suitable level of cleanliness, then they will then have to be cleaned within the cleanroom; this is unlikely to be as effective. The number of firms who produce components in cleanrooms is growing, but many have manufacturing conditions that are less than ideal. It may be possible to persuade your supplier to adopt suitable contamination control measures. If your company, or the total cleanroom industry, has sufficient buying power, the manufacturing company may wish to safeguard their market by producing products of the appropriate degree of cleanliness.

226

Technology

Cleanroom

A visit to the premises ofyour supplier to audit their facilities is essential. The manufacturer may not be acquainted with cleanroom technology, and some simple suggestions and changes to their manufacturing process may produce useful dividends. Even if the manufacturer has no cleanroom, a higher level of housekeeping, the use of cleanroom gloves, wipers and non-linting clothing may make a considerable difference to the quality of the product. Attention should also be paid to storage and packaging. If the productcanbe taken from the production machine andimmediately wrapped in suitable clean packaging, the effect of the poor surrounding conditions isminimised: this may be sufficient for your purposes.

18.3 Wrapping Materials Wrapping ofcleanroomitems should not only prevent damage during transportation, but minimise contamination. An example will illustrate this. If a component isplaced into a cardboard box and delivered to a cleanroom then its outside will be contaminated with wood fibres. Even if the component is put intoa clean plastic bag before being placed in a cardboard box, the outside of the plastic bag will be contaminated with wood fibres; it will then be very difficult to openthe bag without getting fibres onto the component. This problem can be overcome if the packaging is made from clean materials and multi-layered. Plastic materials are most common materials used for packaging; they are often used either as a film or as pre-formed packaging. Plastic packaging is usually lower in particles, fibres and chemical contamination than many other materials. However, this does not mean that plastic materials are free from contamination. The amount of contamination will depend on the plastic used, and the manner it is made and packaged; its suitability should be checked. Some plastics can produce an electrostatic charge that will harm the product. Static-dissipative plastic is available, and this has the additional advantage ofbeing less likely to attract particles to it, and may therefore be cleaner. Some plasticpackaging, such as that made fi-om PVC, may not be acceptable ifoutgassing is considered a problem.

Equipment Materials,

227

The number of layers of packaging should be considered. If an item used in a cleanroom is wrapped in multiple layers, then it is possible to remove a layer at a time as the materials progress into the cleanroom. This will ensure that items will arrive into the cleanroom cleaner. Vacuuming and damp wiping of the packaging is a useful method, especially in the initial entry stages. However, as the supplies pass into the cleanroom and the packaging gets progressively cleaner, it may become less necessary to clean the outside of the packaging. The following practical example will illustrate one possible approach. Small items for use in a cleanroom are manufactured and packed singly in a pre-formed plastic pack. Groups of ten of these single packs are put into a plastic box with a lid and this is vacuum packed in plastic film. These are then put into a large plastic bag that is placed into a cardboard box for delivery. When the cardboard boxes are delivered to the factory where they are to be used, they are stored in some unclassified storage area for eventual use. When required, the cardboard box is taken to an area outside the materials-transfer airlock and the large plastic bag taken out. The bag can then be vacuumed with a brush attachment. The bag is opened and the vacuum-packed boxes removed and loaded onto a trolley. The trolley is taken into the materials-transfer airlock where the vacuum-packed wrapping is wiped with a damp cleanroom wiper. The wrapping is then cut open and the plastic boxes deposited onto a clean pass-over bench in the airlock; the wrapping should be cut open in such a way as to prevent contamination on the outside of the wrapping getting onto the clean inner items. If the top of a package is cut in a ‘X’ or an ‘I’ shape and the end comers cut down to the bottom of the package it should be possible to strip back the packaging without causing Contamination. This is illustrated in Figure 18.1. The plastic boxes on the pass-over bench are then picked up by cleanroom personnel and taken into the cleanroom. These will then be stored in the cleanroom. When a component in the pre-formed packaging is required the plastic box is opened, the item removed, and the lid shut. The correct method of packaging of items varies a great deal depending on the items being packaged, their use, and the design of the materials airlock. It will therefore be necessary for the cleanroom management to specify suitable packaging materials and devise a protocol for cleaning and

228

Technology

Cleanroom

I”j

/

/

Figure 18.1 Cuttingmethods

removing the layers of packaging as the required item progresses into the cleanroom

18.4 Transfer of Items and Small Pieces of Equipment through an Airlock Items used in manufacturing should be transferred into the cleanroom so that the minimum allowable contamination enters the cleanroom. An airlock prevents air exchange into the cleanroom. A description of airlocks and their function is discussed in Section 5.2.1. When both sets of airlock doors are shut, the supply air dilutes the contamination that enters either through the door from the outside corridor, or is dispersed by the people using it. It is common to find that the outer and inner doors of the materials transfer airlock are interlocked. This is done to ensure that one door cannot be opened until the other one is closed, and this prevents contamination in the outside uncontrolled area being directly transferred into the cleanroom. Cleanroom mats are used at the entry to an airlock, and sometimes into the cleanroom;these prevent the transfer of contaminationon the soles of shoes’ or the wheels of trolleys (carts). An airlock is alsoused to prevent the entry of contamination on the surface of thematerials, and their packing. Given below is a description of two possible methods that can be used to transfer materials through an airlock.

quipment Materials,

and Machinery

229

Depending on the type of materials being transferred and the security of the transfer, either a ‘no-bench’ or a ‘bench’ method is used. These are discussed below.

18.4.l Transfer area with a bench A secure method of transferring supplies into a cleanroom is to use an airlock divided into two zones by a bench. This is not a suitable method for transferring heavy materials and equipment, and an alternative method is discussed in the next section. If a bench is used the following method may be employed. The door from the uncontrolled area is opened and the person enters. The person may walk over a cleanroom mat or flooring to minimise the transfer of outside floor contamination. The pass-over bench is cleaned and, if necessary, disinfected (Figure 18.2).

Figure 18.2 The bench is cleaned

The wrapped items are now brought into the air lock. No packaging material that will cause gross contamination, such as cardboard, should be brought into the airlock. The package should be placed on the ‘wrapped receiving’ or ‘dirtier’ part of the pass-over bench (Figure 18.3).

Cleanroom Technology

230

The wrapping is then cleaned and removed (Figure 18.4); this method depends on the standard of cleanroom being accessed, and is discussed in Section 18.2.

Figure 18.3 Wrapped items placed on ‘wrapped receiving’ sideof bench

Figure 18.4 Wrappingremoved

The outer packaging is now removed and deposited into a suitable container. The item is then be placed on the ‘wrapping removed’ or ‘clean’ part of the bench (Figure 18.5).

and Equipment Materials,

23 1

1

Figure 18.5

L

Unwrapped item place on clean side of bench

The person who has brought in the materials from the outside area will then leave. The airlock may be left fora few minutes to allow the airborne contamination to come down to a concentration that does not significantly affect the cleanroom when the door into the cleanroom is opened. A timer on the door interlocks or light may assist this. Cleanroom personnel now enter the cleanroom and pick up items that have been left (Figure 18.6).

1

L

I Figure 18.6 Cleanroom personnel pick up the material

Cleanroom Technology

232

Figure 18.7 Material taken into cleanroom

Cleanroom personnel then pass back through the inner door and into the cleanroom (Figure 18.7).

18.4.2 Transfer area without a bench An airlock without a bench is often used if it is necessary to pass large heavy pieces of equipment or machinery in and out of the room. It can also be used as a less secure alternative to an airlock with a bench. Such a type of airlock is illustrated in Figure 18.8. Using the methods discussed in the previous sections of this chapter, a clean trolley, or cart, is loaded with materials for use in the cleanroom. It is pushed from the outside uncontrolled area into the transfer airlock and left. Personnel from the cleanroom then enter the transfer area to get the supplies. If the supplies are heavy and cannot be lifted, the trolley will have to enter the cleanroom; it will have to be cleaned in the airlock before this occurs. If the supplies are not heavy, then they can be transferred to a cleanroom-designated trolley that has been brought fiom the cleanroom for this purpose.

EquipmentMaterials, Machinery

and

233

Using a method similar to that discussed in previous sections of this chapter, the item’s packaging is cleaned, or removed, or both. The cleanroom trolley (cart), is then taken into the cleanroom and the doors closed. Depending on whether the trolley is required for removing out-going goods, or to bring in more supplies the ‘outside’ trolley can be removed, or left.

Figure 18.8 Material-transfer area suitable fora trolley or bulky machinery

It may be considered necessary to use a cleanroom mat or flooring to remove the contamination from the wheels of the trolley (cart), as it is pushed into the cleanroom.

18.5 Entry of Machinery Machines, and other heavy and large bulky items of equipment, are occasionally taken in or out of a cleanroom. The method to do this should have been established when the cleanroom was designed. Unfortunately, this is not always done. The best solution to the movement of bulky items is to design the materials airlock to be large enough to allow the entry and exit of every piece of machine to be brought in or out of the room. As has been discussed in the

234

Technology

Cleanroom

previous section, thematerials airlock may be divided into two parts by the bench. If it is anticipated that the chance is small of a large machine being brought in or out of the cleanroom, then the bench system can still be used. However, the bench should not cause an obstacle by being (a) designed with the floor covering passing up and over it, (b) permanently attached to the floor, or (c) with a lip on the floor. Another design solution for getting machinery in and out of acleanroom is to provide a set of double doors in the cleanroom wall that are large enough for the machinery or plant items to pass through. These are likely to give direct access tothe outside corridor, and must therefore be locked, except when needed for the entry of machinery. Some types of modular wall panels can be removed and replaced without disruption, and this is an alternative to doors. Both these methods are not as good as an airlock, as it is not possible to ensure that the machinery is clean when it enters the cleanroom, or that outside contaminated air will not get into the cleanroom. It will therefore be necessary when the machinery has been placed in the cleanroom to clean the machinery, clean the cleanroom and then carry out tests to ensure that the disruption has not compromised the cleanroom’s cleanliness. It is quite common in established cleanrooms to find that the materials airlock is toosmall for machinery, there is no doorway in the wall, and that wall panels cannot be easily removed. Sometimes it is possible to get the machinery through the changing rooms, but if the materials airlock is too small, it is likely that the changing area is as well. In this situation, there are two possible solutions: 1. Cut a panelin the wall of the production room so that the machinery can pass through from the outside corridor. This hole in the wall can then be reinstated, preferably with double doorsfor future use. After the machinery has been commissioned, the cleanroom can then be cleaned, tested and production restarted. This method cannot be used if production must continue in the cleanroom. It is also particularly ineffective if it has been necessary to effect an entry through materials that disperse copious amounts of contamination, suchas plaster panels orbricks and mortar. 2. A temporary airlock can be constructed on the inside surface of the wall of the cleanroom. For better security, an airlock should be built on both

Materials, Equipment and Machinery

235

sides. The wall can then be penetrated and a doorway built in the wall. If these airlocks are now effectively cleaned and cleanroom mats used to minimise foot-borne transfer, they can be use to test and clean the machine before it passes into the cleanroom. If this method is expertly done, it is possible to continue production within the cleanroom during the modifications. The equipment used to lift the heavy machinery and similar items into a cleanroom is unlikely to be suitable for cleanroom use. It can be cleaned, but this is unlikely to be sufficient. It may therefore be necessary to cover the lifting equipment with clean plastic film that istaped in place.

18.6 Transfer of Materials through Hatches and Sterilisers Items for use in a cleanroom can be transferred into cleanrooms by methods other than a materials transfer airlock. A popular means of transferring small items in or out of a cleanroom is by the use of a transfer hatch. The actual size of the hatch will depend on the size of the materials being transferred, but the transfer hatch shown inFigure 18.9 has doors approximately 90cm by 90 cmand a depth of about 40 cm.

Figure 18.9 Pass-through hatch

Cleanroom Technology

236

The transfer hatch works in a similar way to a materials airlock. If an item ispassed into a cleanroom, the following method may be used: 0

0

The person outside the cleanroom opens the transfer hatch door and cleans the hatch. A layer ofpackaging is taken off and the item placed into the passthrough hatch. Thedoorisshut. The person on the other side of the hatch opens the inner door and removes the item. These items may be cleaned, or another layer of packaging removed if higher contamination control is required.

It is common to find that the transfer hatch has an electrical or physical type of interlock that prevents the two doors being open at the same time, and thus preventing an undesirable exchange of air into the cleanroom. Hatches can alsobe constructed at floorlevel. This allows heavier items to be more easily transferred through the hatch. Sterilisers, such as autoclaves and hot air ovens, are used to transfer materials in and out of biocleanrooms. To do this efficiently, double-door sterilisers, are used. The door outside the cleanroom is opened and the nonsterile material is loaded into the steriliser. The steriliser then proceeds through its sterilising cycle. After it is complete the steriliser door into the cleanroom is opened and the sterilised materials removed. It is alsopossible to use sterilising tunnels, where containers are sterilised as they pass from the outside to the insideof the cleanroom.

Acknowledgement Figure 18.9 is reproduced by permission of Thermal Transfer.

19 Cleanroom Clothing Large amounts of contamination are dispersed from the people in cleanrooms. Special clothing is therefore worn in all cleanrooms to control the particle and microbiological dispersion from people and hence the contamination within cleanrooms. The use of clothing to reduce the dispersion of contamination originated in hospitals. At the end of the 19" century it was realised that surgeons who inspected patient's infected wounds in hospital wards transferred bacteria-containing pus and blood onto their clothing. When they moved to theoperating room they infected wounds.

Figure 19.1 Old operating room clothing.

238

TechnoloPy

Cleanroom

To protectthepatient's wound during surgery, sterile gowns were used. Figure 19.1 shows an old operating room where the surgeon in the forefront of the picture can be seen wearing a sterile gown over his normal clothes. How airborne contamination is dispersed, and the role of cleanroom clothing in reducing this, can be conveniently considered in two parts, i.e. inert particles andmicrobe-carrying particles.

19.1 Sources and Routes of Inert Particle Dispersion The airborne dispersion ratefrom people varies from person to person, the greater their activity the more particles they disperse. Dispersion is dependent on the clothing worn, but can be in the range of l O6 to l O7 per minute for particles2 0.5 pm, i.e. up to 10" per day.

Figure 19.2 Sources and routes of particles and microbe containing particles from people

Clothing

239

People may disperse particles from: 0

0 0

skin clothing they wear under cleanroom garments cleanroom clothing mouthand nose.

The routes of dispersion of particles are through the following parts of cleanroom clothing: 0 0 0

fabric poor closures at the neck, ankles and wrists holes andtears.

These routes and sources shown in Figure 19.2, are those that occur when coveralls are worn. However, when coats or smocks are worn, there is no barrier between a person’s legs and the bottom edge of the coat, and contaminated is freely dispersed from underneath.

19.1. l Sources ofparticles and mechanisms of release The sources of particles are listed in the previous section and shown in Figure 19.2. These are now discussed in more detail in relation to their importance and the mechanisms ofreleasing particles. 19.1.1.1 Skin People shed approximately lo9 skin cells per day. Skin cells are approximately 33pm x 44 pm and found in the cleanroom either as whole cells or fragments. Figure 19.3 shows a photograph of the surface of the skin taken by means of an electron microscope. The lines shown in the photograph delineating the individual skin cells and beads of sweat on the surface. The amount of sweat shown is equivalent to that generated by one hour of exercise. Skin cells may be released onto clothing and laundered away; others are washed away in the bathtub or shower. However, a large number are

240

Technology

Cleanroom

Figure 193 Skin surface showing skin cells and beads of sweat

dispersed into the air. These skin particles are a major source of airborne contamination.

19.1.1.2 Clothing under cleanroom clothing What people wear under their cleanroom garments has a large effect on their inert particle dispersion rate. If their inner clothing is made from natural fabrics, such as a cotton shirt, cotton jeans and woollen jersey, they disperse large quantities of particles. The reason for this is thatthese natural materials have fibres that areboth short and break up easily. Figure 19.4 shows a photograph of the structure of cotton, and it is not difficult to envisage fragments of the fibres breaking off. These fragments then combine with the dispersed skin particles and pass through the outer cleanroom garment. However, if the inner clothing is made from synthetic fabric, the particle challenge from the inner garments can be reduced by 90% or more. It can be reduced even more if the inner garment has a good filtration efficiency against the skin particles.

Figure 19.4 Cotton fabric photographed through a microscope. Magnification about 100 times

Cleanroomclothing The cleanroom industry has placed considerable emphasis on minimising the particles dispersed from cleanroom clothing, i.e. on non-linting properties of the fabric and the cleanliness of the clothing. As will be discovered from further reading of this chapter, this isoveremphasised. Although natural fabrics, such as cotton, give off an unacceptable number of particles, these are never (and must never be) used in cleanrooms. Cleanroom clothingis made from fabrics manufactured from synthetic plastic materials, such as polyester or nylon. These fabrics are unlikely to break up when used in cleanroom clothing, and have been shown to contribute about only 5% of the total numberof particles dispersed by a person; the majority of particlescome from a person’s skin orinner clothing. Figure 19.5 shows a photograph of the structure of a synthetic cleanroom fabric. It can be seen that the fabric is woven from threads made from continuous synthetic monofilaments, and this ensures that few particles are dispersed from the fabric. 19.1.1.3

19.1.1.2 The mouth and nose People will disperse particles from their mouth or nose. When people sneeze, cough or talk, they emit particles. Snorting through the nose also disperses particles. These mechanisms, and the means of preventing them, are discussed in Chapter 20.

19.I .2 Routes of transfer of particles Although a fabric of the type shown in Figure 19.5 sheds few particles by breaking up, they do little to prevent particles passing through them. The pores at theintersection of the threads of this fabric arebetween 80pm and 100pm, this being caused by the monofilaments having a large diameter and the fabric not being woven tightly. The particles generated from the skin and the innerclothing therefore pass-through easily. This is therefore not a desirable cleanroom clothing fabric. A cleanroom fabric should be manufactured so that it can prevent particles passing through. This is discussed later in Section 19.3.

Figure 19.5 A poor cleanroom fabric with large pores (about 80pmto 100 pm equivalent diameter)between the threads

As personnel move, a pressure builds up under the cleanroom clothing. The pressure is greater as the air impermeability of the fabric increases. The particles under the cleanroom clothing may then be pumped out of closures at the neck, ankles, wrists and zips. Secure closures can prevent this, and although they should be tight, they should not be uncomfortable. If a garment has tears or holes, particles can easily pass through. If a garment such as a smock is worn, it will not fully envelop a person and particles flow out from under it and into the cleanroom.

19.2 Routes and Sources of Microbial Dispersion The sources and routes of microbe-containing particles from people are the same as with inert particles and shown in Figure 19.2. However, the relative importance of th.e microbial sources is different.

19.2.1 Sources of micro-organisms People are normally the only source of micro-organisms in a cleanroom. Almost all of the airborne micro-organisms found in the cleanroom air come from people’s skin, although some come fi-om the mouth and nose. Information on dispersion from the mouth and nose is discussed in Chapter 20. People shed one outermost layer of epithelial cells every 24 hours. A small but significant proportion of these is dispersed into the cleanroom air with micro-organisms on them. Micro-organisms grow and divide on the skin, and can be found as either a small microcolony, or individual cells. Figure 19.6 shows a microcolony on the skin with about 30 bacteria in it. The majority of skin cells dispersed into the environment do not have micro-organisms on them, On average, about one in ten of the skin cells dispersed have micro-organisms on them; they are likely to have an average of about four microbes on each. The type of micro-organisms on airborne skin cells is almost always bacteria, this being a reflection of the type of microbes foundon the skin.

244

Technolopy

Cleanroom

Figure 19.6 Microcolony of bacteria on surface of skin

Most microbe-carrying particles in the air of a cleanroom come from the skin. Large numbers of inert particles come from the person’s inner clothing and small numbers from the break up of cleanroom clothing. These two sources are not primary sources of microbe-carrying particles.

19.2.2 Routes of microbial dispersion The routes of transfer through cleanroom clothing are the same as with inert particles and shown in Figure 19.2. These are: 0

the pores in the fabric poor closures at the neck, sleeves and ankles damage to the fabric, i.e. tears and holes.

Microbe-carrying particles are also expelled from the mouth. When a person is breathing, microbial dispersion istoo low to be measured but speaking, coughing and sneezing produce significant numbers. This is discussed in the next chapter.

Clothing

245

People disperse large numbers of microbe-carrying cells. When males wear ordinary indoor clothing, an airborne dispersion rate of1000microbe-carrying particles per minute is not unusual, the average rate being closer to 200 per minute. Females will generally disperse less. Closely-woven fabrics are more effective in reducing microbial than inert particle dispersion. The reason for this is that the average size of microbe-carrying skin cells is much larger than the inert particles found in the air. Microbe-carrying particles in cleanroom air have a size spectrum from less than 1 pm to over 100 pm, with an average equivalent diameter of between about 10 pm and 20 pm. They are therefore small enough for many of themto pass through the pores in cleanroom fabrics

19.3 Types of Cleanroom Clothing 19.3. I Clothing designs The most effective type of cleanroom clothing is that which completely envelopes a person. It should also be made from a fabric that has effective filtration properties and have secure closures at the wrist, neck and ankle. However, this type of clothing can often be the least comfortable and most expensive. The choice of clothing will depend on what is being produced in the cleanroom. A poorer standard of cleanroom may use a cap, zip-up coat (smock) and shoe covers (Figure 19.7). In a higher standard of cleanroom a one-piece zip-up coverall, kneehigh overboots and a hood that tucks under the neck of the garment will be typical (see Figure 19.8). A spectrum of design exists around these two general types of garments. Some of the best cleanroom clothing can be 10 times more costly than the most basic. However, it can be cost effective to buy good cleanroom clothing. It is not unusual for a firm to pay several million dollars, or pounds sterling, for a new cleanroom that is used by less than ten people. The firm’s buyer may then purchase the cleanroom clothing. They may be ignorant of the fimction of clothing and refuse tospend a little extra money to buy clothing that will achieve a dropin bacterial or particle contamination similar to that achieved by the new cleanroom.

246

Cleanroom Technology

Figure 19.7 Cleanroom garments suitable for a lowerstandard of cleanroom

19.3.2 Cleanroomfabrics The type of fabric is an important consideration when choosing a cleanroom garment. Cleanroom fabricsshould be resistant to break-up (linting). A more important property is their ability to filter the contamination generated from the skin and clothes worn under the cleanroom clothing. The fabric’s effectiveness can be assessed by measurement of the air permeability, particle retention, and pore-size. These tests are discussed in Section 19.6.

Clothing

247

Figure 19.8 Cleanroom garments suitable fora higher standard of cleanroom

The most popular type of clothing is made from woven synthetic fabrics, the most common being polyester. This type of clothing is worn, processed in a cleanroom laundry and worn again. Figure 19.9 shows a cleanroom fabric that is made from finer monofilaments of polyester and is more tightly woventhan the poor fabric shown in Figure 19.5; it is therefore a better particle filter. This type of fabric is similar to that often used in cleanrooms. However, more tightly-woven fabrics made from smaller diameter microfibres are also available. These work even better as long as the closures at the neck, ankles and wrists are able to prevent the extra pressure generated by the lower air permeability of these fabrics.

248

Technolopy

Cleanroom

Figure 19.9 Typical construction of a cleanroom fabric

Non-woven fabrics, such as Tyvek, are used as single, or limited reuse, garments. They are popular for visitors and are used by builders when constructing the room. They are also popular in pharmaceutical manufacturing facilities in the USA. Other non-woven fabrics are successfully used in the manufacture of cleanroom garments. Membrane barrier fabrics, such as GoreTex, which use a breathable membrane sandwiched onto, or between, synthetic woven fabrics, are very efficient; they are expensive, and hence are used in the higher standard rooms. The movement of a person generates an air pressure behind the garment fabric; the tighter the construction the higher the pressure. This will result in unfiltered air being pumped out of the closures of the clothing. Closures at the neck, cuffs and bottom of trousers must therefore be secure. The numberof holes and tears in garments must be kept to a minimum. If this is not done, contamination from the inner garments and skin will flow through unhindered. Garments should therefore be inspected at the laundry and before being put on. Any garments with holes or tears should not be used in a cleanroom. Care must also be taken to minimise holes in the garment by means of good construction.

Clothing

249

19.3.3 Garment construction To ensure good construction of cleanroom garments, the following methods should be used: To prevent the raw edges of the fabric fraying, the edges should be either covered, interlocked, heat seared or laser cut. To minimise contamination, the edges of the fabric should be encapsulated in seams. These seams should also minimise the escape of particles caused by needle punctures. To minimise contamination, the sewing threads shouldbemadeof synthetic continuous filament. 0

0

0

To minimise shedding, the zippers, fasteners andshoe soles should not chip, break up or corrode. They should be able to stand up to multiple laundering and, where necessary, sterilisation. To prevent dirt collecting, there should be no pockets, pleats, darts or hook-and-pile fasteners (Velcro). To minimise contamination, elasticised or knitted cuffs should not collect or shed particles.

19.3.4 Choice of garments The type of garments used in cleanrooms can vary. Information on the type of clothing that should be worn in different types of cleanrooms is given in the IEST Recommended Practice RP-CC-003.2. The information given in the Recommended Practice is summarisedin Tables 19.1 and 19.2. Table 19.1 gives suggestions for different classes of cleanroom and Table 19.2 provides suggestions for aseptic cleanrooms.

250

Technolopy

Cleanroom

Table 19.1 Garment systems for different classes of cleanrooms according to IEST-RP-CC-003.2 ~~~~~~~

~

IS07 & 8

Apparel Type

(100K and

IS0 6 10K)

IS05 (100)

IS04&3

(1000)

(10 and l )

Frock

R

AS

AS(NR*)

NR

2 piece suit

AS

AS

AS

AS

Coverall

AS

R

R

R

AS(NR*) R

NR R

Shoe cover

R

Boot

AS

AS R

Special footwear

AS

AS

AS

AS

Hair Cover (bouffant) R

R

R

R

Hood

AS

AS

R

R

Facial cover

AS

AS

R

R

Powered headgear

AS

AS

AS

AS

Woven gloves

AS

AS

AS

NR

Barrier gloves

AS

AS

AS

R

Inner suit

AS

AS

AS

R

NR = not recommended (NR*) = not recommended in nonunidirectional flow

R = recommended AS = application specific

Table 19.2 Garment systems for aseptic cleanrooms (IEST RP CC-003.2) IS0 Class 7

IS0 Class 6 and 5

I S 0 Class 4 and 3

(Class 10000

(Class 1000 and 100)

(Class 10 and 1)

Frock

NR

NR

NR

2 piece suit Coverall Shoe cover Boot Special footwear Hair cover (bouffant) Hood

NR

NR

R

R

NR R

NR

NR

NR

R

R

R

AS

AS

AS

R AS

R R

R

Apparel Type

R

Facial cover

R*:*

R**

R**

Powered headgear

AS

AS

AS

NR

NR

NR

Woven gloves R Barrier gloves Inner suit R = recommended AS = application specific

R

AS

R

AS

R

NR = not recommended R** = surgical mask recommended

Information on clothing for pharmaceutical cleanrooms is also given in the European Union Guide to Good Manufacturing Practice (1997 edition). The type of clothing expected in the various grades of pharmaceutical cleanrooms is as follows: 'Grade D [approximatel,yequivalent to IS0 Class 8 (Class 100 OOO)]: Hair and, where relevant, beard should be covered. A general protective suit and appropriate shoes or overshoes should be worn. Grade C [approximately equivalentto IS0 Class 7 (Class 10 OOO)]: Hair and, where relevant, beard and moustache should be covered. A single or two-piece trouser suit, gathered at the wrists and with high neck and appropriate shoes or overshoes should be worn. They should shed virtually no fibres orparticulate matter. Grade A/B [approximatelyequivalent to IS0 Class 5 (Class loo)]: Headgear should totally enclose hair and, where relevant, beard and moustache; it should be tucked into the neck of the suit; a face mask should be worn toprevent the shedding of droplets. Appropriate sterilised, nonpowdered rubber or plastic gloves and sterilised or disinfected footwear should be worn. Trouser-legs should be tucked inside the footwear and garment sleeves into the gloves. The protective clothing should shed virtually no fibres orparticulate matter and retain particles shed by the body I.

19.3.5 Comfort Cleanroom clothing can sometimes be hot and uncomfortable, and an effort should be made to maximise comfort. Clothing should therefore be provided in a selection of sizes. If the clothing is reusable it is quite common to have personnel measured and issued with their own clothing. The

252

Technology

Cleanroom

design of cleanroom garments should also provide closures at the neck, ankles and wrist that are atight, yet comfortable. Shoe coverings can cause problems. Simple, thin-plastic shoecoverings can tear, fall off and stick to cleanroom flooring. If more substantial shoe coverings are selected, the sole should not mark flooring, or slip on wet floors. It is also important to find a good system of tying to ensure that they stay in place. The thermal comfort of cleanroom garments can be assessed by.comfort indexes, suchas water vapour permeability and Cl0 values. However, although these give an indication of comfort, it is best to get your personnel to try clothing out in your cleanroom. Inevitably, personnel will prefer garments that give the minimumof protection, as they are usually the most comfortable. It will be up to management to ensure that contamination control properties are pre-eminent, but a certain amount of trade-off may be necessary.

19.4 Processing of Cleanroom Garments and Change Frequency 19.4.l Processing

Cleanroom clothing becomes contaminated during use and has to be replaced by fresh items. If disposable clothing is used it is simply thrown away, although some types can be processed a few times. If it is to be reused, then it is usually cleaned in a cleanroom laundry. Other processes, such as antistatic treatment and disinfection or sterilisation, can also carried out by a cleanroom laundry. Cleanroom laundries are built solely for processing cleanroom garments. A typical cleanroom laundry will have a design similar to that shown in Figure 19.10. There will be a ‘soil area’ where the garments are received and sorted out tominimise cross-contamination. Shoe coverswill be separated. Some cleanroommanagers are concerned toensure that chemicals, or other toxic contaminants, are not transferred to or from their garments.

p+/SOIL AREA ( I S 0 Class 5 )

Washer

FOLDING AREA ( I S 0 Class 3 / I S 0 Class 2)

Test Station /Table

\

Shelf for supplies (e.g.poly

er

bogs1

Pass-through hatch

PACKING AREA ( I S 0 Class 7 or preferably Class6)

+Figure 19.10 Diagram of a cleanroom laundry

The garments will then be put into a pass-through washer so dirty clothing can be fed into one side of the washer and clean garments emerge into the folding area. The washer will be fed with water that has been processed to purify it. Dry cleaning machines are also used. When the garments come out of the washing machine they will come into the folding area where the operators work in cleanroom garments. The cleanroom clothing isthen

254

Technolopy

Cleanroom

loaded into a tumbler dryer that issupplied with filtered air. When dry, the cleanroom garments are inspected for holes or tears, folded and placed in clean bags. These are sealed and passed out of the folding area through a hatch into the packaging area for dispatch. A photograph of a cleanroom laundry in operation is shownin Figure 19.11.

Figure 19.11 Cleanroom laundry showing the washers, tumble dryers and table for folding

If clothing is to be fiee of micro-organisms then the garments must be sterilised or disinfected. Sterilisation, i.e. the killing ofall microorganisms, can carried out by heat, gas or radiation methods. None of these methods is completely satisfactory. Autoclaving can cause substantial creasing and slow deterioration of the fabric. Gases such as ethylene oxide are gentler on the fabric, but their toxicity means that there can be problems with gasin the clothing and clothing must be left to off-gas. Gamma radiation is a popular method, although this can cause discolouration of clothing and, in time, a breakdown of the materials. Another

Clothing

255

approach is to use disinfectants in the wash. This method should not damage the fabric and is more economical. However, it is possible that some micro-organisms may be left on the garment, and hence this method may not be acceptable. The effectiveness of the cleaning process is normally checked by counting the number of particles on the surface on theprocessed garments. Samples are usually tested in the folding area (atthe test station shown in Figure 19.10). Methods used are described in the IEST RP-CC-003, and are based on either theAmerican Society for Testing of Materials (ASTM) F61 standard, or the tumbling drum test

19.4.2 Frequency of change The frequency of the change of cleanroom clothing varies. One might expect that the more sensitive the process is to contamination, the more fiequent the changing will be.However, this is not necessarily so. In the semiconductor industry where the cleanrooms are of the highest specification, clothing may be changed once or twice a week, with no apparent adverse effect in the airborne quality of the room. On the other hand fresh garments are put on every time personnel move into an aseptic pharmaceutical production area. Guidance as to the frequency of the change of garmentsin a typical cleanroom is given in the IEST RP-CC-003 and shown in Table 19.3.

Table 19.3 Recommended frequencyof change of garment according to the IEST RP-CC-003 Class of Room

IS0 7 and 8 (Class 10 00 100 and 000)

IS0 6 (Class 1000)

Frequency

2 per week 2 per

toper 3daily per entry week

day

2

IS0 5 (Class 100)

IS04 (Class 10)

to

IS0 3 (Class 1) on each entry

256

Technology

Cleanroom

19.5 The Effect of Laundering and Wear In terms of particle removal efficiency, a garment is usually at its best when new. As it gets older the fabric will open up and allow more particles to be pumped through. The reason for this is that most cleanroom fabrics are calandered at manufacture by passing them through high-pressure rollers to squeeze the fabric and reduce the pore size. Fabrics that are more heavily calendered are more likely to relax through washing and use, and open up. I have investigated the pore size and particle penetration of two garments when they were new and after being washed 40 times. One garment was made from a heavily calandered fabric, and its pore size increased from 17.2 pm to 25.5 pm, but the other identically woven fabric, which was less heavily calandered, only increased from 21.7 pm to 24.6 pm. A similar change in particle penetration was also observed. Clothing from one cleanroom user that was said to have been washed ‘hundreds of times’ had a pore diameter that increased from 18 pm, when new, to 29 pm. It is clear that the contamination control properties of garments can deteriorate with use and that some fabrics will be worse than others. There is also a problem with holes and tears in the garments caused by accidents or wear. Personnel should check garments before they put them on; they should also be checked at the cleanroom laundry.

19.6 Testing of Cleanroom Clothing Laboratory testing can assess the contamination properties of different types of clothing. The first type of testing is that of the fabric; these tests will ascertain its likely filtration properties. The second type of test is concerned with the performance of the whole clothing system; this is usually carried out in a body box. Further information on methods for testing clothing is given in the IEST RP-CC-003.

Clothing

257

19.6.I Fabric tests My studies of the contamination control properties of cleanroom fabrics showed a wide variation in their properties. The equivalent pore diameter of varied from 17 pm to 129 pm, the air permeability from 0.02 to 25 ml/s/cm2, the efficiency of removalof particles 2 0.5 pm from5% to 99.99%, and particles 2 5.0 pm from - 4 % to 99.99%. This wide variation in the contamination control properties showed that care should be taken in choosing fabrics. These laboratory tests identify fabrics that are likely to perform well whenmade into clothing. However to comparecomplete garments, a method that comes close to the real situation in a cleanroom is the body box test.

19.6.2 Dispersal of airborne bacteria and particles The body box, which I first designed in 1968, is shown in Figure 19.12. Through a HEPA filter in the top of the box, bacteria and particle-free air is supplied. A volunteer enters the box wearing the clothing to be studied. After the contamination in the box has been blown out, the volunteer starts to exercise to the beat of a metronome. The number ofparticles and bacteria dispersed per minute are then counted. The usefulness of the body box is illustrated by some results. 19.6.2.1 Effect of the garment design on dispersion Garments should be designed to envelop personnel and prevent the dispersion of contamination. 'The average number of the bacteria dispersed per minute from a male volunteer in a body box is given in Table 19.4. The person wore their normal indoor clothing and then put on different designs of cleanroom clothing made from the same good quality synthetic fabric.

258

Technology

Cleanroom

Figure 19.13 Body box: a, metronome; b, bacterial and particle sampler

It is clear from these results that the more the clothing envelops the wearer, the better the result. A surgical-type gown worn over a person’s everyday clothing is effective in reducing dispersion, but cannot stop the dispersion coming out from underneath it. A shirt and trouser system is more effective, but air will spill out the open neck and trouser legs. When a coverall with a tuck-in hood and knee-high boots is worn the best result are obtained.

Clothing

259

Table 19.4 Effect of design on bacterial dispersal rate (counts per minute)

Own clothes Gown

over own clothes trousers

Open-necked shirt and of good fabric

Cleanroom coverall

610

180

113.9

7.5

19.6.2.2 Comparison of clothing made from different fabrics A comparison was made of a male volunteer wearing his normal indoor clothing and cleanroom clothing. The volunteer wore either (a) his underpants only, (b) his normal underpants, shirt, trousers, socks and shoes and (c) different types of cleanroom suits with hood, full-length overboots and latex gloves. The different types of cleanroom suits were made from three fabrics. These were: 1 . the pooropen fabric shown in Figure 19.5 with a pore diameter of about 100 pm; 2. the tighter fabric shown in Figure 19.9 with a pore diameter of about 50 pm; 3. GoreTex fabric madefrom a membranesandwiched onto polyester fabric and impermeable to the sizes ofparticles measured. A GoreTex suit was also tested with special elasticised closures designed to make an escape of air less likely. Shown in Table 19.5 is the average number of bacteria dispersed per minute from the male volunteer when he wore different sets of clothing. The greatest dispersion occurred when only underpants were worn, but the addition of another filtration layer, i.e. his shirt and trousers, reduced the rate. However, this would not be paralleled if inert particle counts were measured, unless the clothing waslow linting andhadgood filtration properties. It can also be seen that the poor fabric with large pores reduces bacterial dispersion, but a tight fabric performed even better.

Technology

260

Cleanroom

Table 19.5 Bacterial dispersion (countdmin) in relation to fabrics Underpants Underpants OpenGoreGoreTex Tight + shirt + trousers

‘special fabric fabric Tex

487

1108

103

11

27

0.6

As the air permeability increases, the amount of air pumped out of the garments’ closures, (i.e. cuffs, neck etc.) increases. The pressure inside a GoreTex suit is many times greater than a garment made of a woven fabric. This is reflected in the fact that a higher dispersion rate than expected was found. However, when a GoreTex garment with special closures to minimise air escape was tested, a further large reduction in bacterial dispersion was achieved. This gave a dispersion rate 170 times less than the open fabric. The above tests were also carried out to measure dust particles. Shown in Table 19.6 is the particle dispersion per minute. Table 19.6 Particle dispersion rate per minute in relation to fabric Cortex Cortex Tighter Open clothes Own closures’ ‘special Particles

fabric

4.5

x

lo6

fabric 8.5 x 10’

5.0 x105

8.2 xlOr

3.5 x 1 ~ 4

3550

3810

2260

74

2 0.5 pm

Particles

1.2 x10‘

2 5.0 pm

It is interesting to note the general ineffectiveness of cleanroom clothing in preventing the dispersion of small particles (2 0.5 pm). If the ‘special closures’ GoreTex clothing are excluded, it is seen that cleanroom clothing gave only a small reduction in the dispersion of particles 2 0.5 pm (from 106/min to 105/min). However, these cleanroom garments were much more effective in removing larger (2 5.0 pm) particles.

Clothing

26 1

19.7 Static Dissipative Properties of Clothing The antistatic property of clothing is important in some parts of the cleanroom industry, e.g. in the microelectronics industry where electrostatic charges may destroy micro-circuits. As peoplemovearound the cleanroom, the rubbing of their cleanroom clothing against seats and benches, as well as inner clothing and skin, generates electrostatic charges within the fabric. This static electricity can then discharge to a microcircuit and destroy it. Cleanroom fabrics are therefore manufactured with continuous threads of conducting material built into the fabric. The following tests can be used to choose clothing that minimise electrostatic discharge: 0 0 0

the measurement of the resistivity, or conductivity; the measurement of the voltage decay; the measurement of the voltage produced by a movingpersonwhen wearing a garment.

Several methods exist for determining the surface resistance of fabrics. The lower the resistance, the better the fabric, as it is assumed that static electricity is more easily conducted away. The antistatic properties of a fabric may be measured by noting the time it takes for a given static charge to decay from the fabric. This is a better test than measuring conductivity. A known charge is generated on the fabric, and the time for this to reduce to % (or 1/10) of its voltage is determined. Times quoted can vary from less than 0.1 second to over 10 minutes, a shorter time indicating a better fabric. Shown in Table 19.7 are results published by the British Textile Technology Group, comparing the static charge generated by people wearing garments made of two fabrics. The fabrics were identical except that one had antistatic strips (resistivity of lo6 ) and the other fabric was without strips (resistivity l O I 3 ). A person wearing a garment made from one of these fabrics got up from a chair and their body voltage was measured when they touched a voltmeter. When the person and chair were insulated from earth, a maximum voltage of 32 10 volts was obtained from the standard fabric, and 2500 volts from the fabric with the conductive strips. This is not a very large benefit. However, if the chair was earthed and conduc-

262

Technology

Cleanroom

tive footwear worn, substantially better results were obtained (see Table 19.6). These results emphasise the need for earthing the chair, the person and the clothing. They also show the limitations of conductive strips in fabrics. Not investigated was theeffect of electrically connectingthe various items of fabric in a garment. Where the various parts of the garment are conventionally stitched together theconduction of electrostatic charge is poor. This can be substantially improved if the garment parts are electrically connected. Table 19.7 Body voltage with and without antistatic strips Antistatic strips

No strips

(ohms) Resistivity

1o6

10”

voltage Maximum body

2500V

3210V

160V

160 V

- insulated leather chair

voltage Maximum body - earthed; leather chair;

conductive footwear

Acknowledgements Figure 19.3 is reproduced by permission of the Science Photo Library. Figure 19.6 is reproduced by permission of St John’s Institute of Dermatology. Figures 19.7 and 19.8 are reproduced by permission of Contamination Control Apparel. Figure19.10 is reproduced by permission of C W Berndt. Figure 19.11 is reproducedby permission of Fishers Services. Tables 19.l , 19.2 and 19.3 are compiledfrom information made available by permission ofthe Institute of Environmental Sciences andTechnology.

20 Cleanroom Masks and Gloves 20.1 Cleanroom Masks Peopleexpellargenumbers of saliva droplets from their mouthwhen sneezing, coughing and talking. These droplets contain salts and bacteria, and itisnecessary to preventthemcausingcontaminationinthe cleanroom. Wearing a mask over the face normallydoes this. The dispersion of droplets and the means of controlling dispersion are discussed below.

20. l .l Dispersion from the mouth ShowninTable 20.1 aretypicalnumbers of particles andmicrobecarrying particles that are dispersed by sneezing, coughing and speaking loudly. The number of particles produced by breathing is not reported but is low anddifficult to ascertain accurately. Table 20.1 Number of inert and microbe-carrying particles emittedby a person InertparticlesMicrobe-carryingparticles One sneeze One cough Loud speaking (100 words)

1 000 000

39 000

5000

700

250

40

264

Masks and Gloves

Figure 20.1 Particles emitted during a sneeze

Figure 20.1 shows droplets produced by a sneeze frozen inmid air by high-speed photography. Figure 20.2 shows the lower number of droplets that areproduced by pronouncing the letter ‘f. Saliva particles and droplets dispersed from the mouth vary in diameter from about 1 pm to about 2000 pm; 95% of them lie being between 2 and 100 pm, withan average size of about 50 pm. Although the count of bacteria in saliva is normally over lo7 bacteria per ml, not all of the emitted particles will contain bacteria. What happens to these expelled droplets and particles depends on their size and hence their rate of drying and settling. If the particles are large, their rate of settling caused by gravitational forces is high, and they will fall quickly and not have time to dry. Small particles will not fall quickly, but will dry and pass into the air circulation of the cleanroom. The time it takes for particles of water to deposit by gravity can be calculated. A 100 pm particle will drop 1 metre in about 3 seconds, but a 10 pm particle takes about 5 minutes. It is also possible to calculate the drying time. Particles of water 1000 pm in diameter will take about 3 minutes to evaporate, a 200 pm particle will take 7 seconds, a 100 pm

Cleanroom

265

particle about 1.6 seconds and a 50 pm particle about 0.4 seconds. It can be calculated that particles have to be less than about 200 pm if they are to dry before they drop a distance of one metre. It therefore follows that some very large droplets of saliva can drop onto products if a facemask is not used.

Figure 20.2 Particles emitted when pronouncing the letter‘f

Because of the small amount of dissolved material in saliva, the evaporation of water from thedrops of expelled saliva reduces the droplets to about one-quarter to one-seventh of their size. These dried particles, known as droplet nuclei, pass into the aircirculation in the room. Many of the particles expelled fiom the mouth are of sufficient size and inertia to be projected onto the inner surface of a face mask, where they will be easily stopped and retained by a layer of fabric. Efficiencies of over 95% for particles expelled from the mouth are usually obtained by most masks. A loss in efficiency is caused by particles passing round the side of the mask, and much of this is due to small particles (reported to be < 3pm in the dry state).

Masks and Gloves

266

20.l .2 Face masks Masks vary in design, but all are made of some type of material placed in fiont of the mouth and nose so that when a person is talking, coughing, sneezing or snorting, the particles expelled are impacted against it,or remove by filtration. A common form of mask is the surgical-style with straps and loops, a typical example being shown in Figure 20.3. The type shown is a disposable surgical-type made from a non-woven fabric and is thrown away when exiting the cleanroom.

-

Figure 20.3 Disposable surgical-type face mask

Consideration should be made of the pressure drop across the mask fabric. Manufacturers can produce masks that have very high filtration efficiency against small particles. However, this high filtration efficiency maybe unnecessary, because of the relatively large size of the expelled droplets and can give a high-pressure drop across the mask that causes the generated particles to be forced round the outside of the mask. This higher pressure can be reduced by the use of masks with a larger surface area of material. Another type of mask is the ‘veil’ or ‘yashmak’ type, one of this type being exposed to show its shape in Figure 20.4. The normal way it is worn is shown in Figure 20.5.

Veils can be snapped into hoods, or permanently sewn into the hood at manufacture. Care should be taken to select a material and style that not only controls the risk fiom emissions fiomthe mouth, but which is acceptable to personnel.

Figure 20.4 Veil or yashmak- type mask shown outside the hood

j

Figure 20.5

Veil or yashmak type mask as normally worn

Masks and Gloves

268

Glasses or goggles can provide an additional barrier to skin flakes, eyebrow hairand eyelashes and keep them from falling onto critical surfaces (see Figure 17.3 in Chapter 17).

20. I . 3 Powered exhaust headgear Several designs of powered exhaust headgear are available. These provide a barrier to contamination coming from the head, as well as the mouth; they also remove contamination pumped out of the neck closure of the garment. The exhaust from the helmet and face-shield is provided with a filtered exhaust system so that contamination does not escape into the cleanroom. An example is shown in Figure 20.6.

Figure 20.6 Poweredexhausthelmet

Cleanroom

269

20.2 Cleanroom Gloves 20.2.I Hand contamination and gloves People’s hands have millions of skin particles and bacteria on them, as well as surface oils andsalts. To preventthisbeingtransferred onto contamination sensitive products, gloves should be worn. There are two types of gloves associated with cleanrooms. Knitted or woven gloves are used for lower classes, i.e. IS0 Class 7 (Class 10,000) and poorer areas, as well as undergloves. The knit or weave should be tight and a number of loose threads minimised. This type of glove is not discussed further. Barrier gloves, which have a continuous thin membrane covering the whole hand are used in the majority of cleanrooms. Thereare a number of problemsassociatedwithcleanroomgloves. Their surface may not be sufficiently free of contamination, as they are not usually manufactured in a cleanroom; they therefore require cleaning beforebeingused.Theyshould thus beselectedwithregardtotheir surfacecontamination and, dependingonthetypeofuse,befreeof particles,oils,chemicals or micro-organisms. Gloves canbepunctured during use, and this allows contamination to pass out. For example, it has been shown that the number of bacteria coming through a glove when it was punctured to give a lmm hole was 7000 from an unwashed hand, and 2000 from a washed hand. Glovesmayberequiredinsomecleanroomstopreventdangerous chemicals, usually acids or solvents, attacking the operator’s hands. An exampleof this problem is theuse of acidsinthewet-etchstepin semiconductormanufacturing.Thisshouldbeborne in mindwhenthe glove is chosen, as thicker and stronger gloves are required. Some operator’s skin is allergic to the materials that gloves are made from. Accelerators in latex, nitrile and neoprene gloves, and the protein in latex,cancauseskinirritations.Hypoallergenicgloves, or innerfabric liners, should be worn to minimise this effect. Otherglovepropertiesthatshould be consideredwhenchoosing a glove arechemicalresistanceandcompatibility,electrostaticdischarge properties,surfaceioncontributionwhenwet,contacttransfer,barrier integrity, permeability to liquids, heat resistance and outgassing.

270

and

Masks

Gloves

20.2.2 Glove manufacturingprocess Gloves are generally manufactured by dipping a ‘former’, the shape of a hand, into molten or liquid glove material. Formers are usually made of porcelain or stainless steel. The formerisremovedfromthemolten or liquid material, and a layer of material allowed to set to form a glove. The glove is then stripped from the former. To allow the gloves to be removed from the former without damage, a release agent is normally employedon the former’s surface. When removed, the release agent will contaminate the outside of the glove. Release agents are a problem in cleanrooms, and hence cleanroom gloves differfromdomestic ones inthat the release agent is kept to aminimum. Gloves are also washedwithaviewto removing the release agent and any other additives added to the dipping medium. An example of this is the use of Magnesium silicate as a release agent in latex gloves made for domestic use. If the Magnesium silicate is replaced with Calcium carbonate, this powder can be removed from the surface byamildacidwash.Anotherway of dealingwiththerelease agent is during stripping. When the gloves are stripped from the former they are ‘inside-out’, and they may then be turned ‘outside-out’ to offset the release agent problem. Glove formulations used in manufacturing non-cleanroom gloves can contain about 15 additives, and a numberof these can cause contamination in cleanrooms. Cleanroom gloves may differfrom those used domestically by minimising, or not using, some of these chemicals. When stripped from the formers, latex gloves are ‘sticky’. To correct this,latex gloves arewashedinachlorinebath. The freechlorine combines chemically with the latex chemical bonds and lead to a ‘casehardening’ of the surface of the glove, which prevents them sticking to each other. This washing also helps to clean to the gloves.

20.2.3 Types of gloves 20.2.3.1 Polyvinyl chloride (PVC) gloves These plastic gloves are also known as vinyl gloves and are popular in electronic cleanrooms. This type of glove cannot be satisfactorily sterilised, and are therefore not used in biocleanrooms. They are available

Cleanroom Technology

27 1

in normal and long-sleeve length, and should preferably be long enoughto cover the cuff of the garment sleeve. Consideration should be madeof the fact that plasticisers make up almost 50% of a vinyl glove. Plasticisers come from the same group of chemicals used to test the integrity of air filters, i.e. phthalates. This material is necessary to make the glove pliable, and also has the advantageof giving the gloves some antistatic properties. However, it can also causes contamination problem from outgassing and contact transfer onto surfaces. 20.2.3.2LatexGloves This is the type used by surgeons, and the ‘particle-free’ type is now used incleanrooms.Latex gloves canbeproduced‘powder-free’,andthose gloves that are washedfurther by use of filtered, deionised water are often used in I S 0 Class 4 (Class 10) or I S 0 Class 3 (Class 1) cleanrooms. They have good chemical resistance, giving protection against most weak acids andbases, and alcohols, aswellashaving a fairlygood resistance against aldehydes and ketones. They are slightly more expensive to buy than the PVC type, but cheaper than any other polymer. They can be sterilised. Because of their elasticity, the glove can securely incorporate the cuff of a garment under the sleeve. 20.2.3.3 Other Polymer Gloves Polythene gloves are used in cleanrooms and have the advantage of being free of oils and additives, as well as resistant to puncturing. They are not resistant to aliphatic solvents. The main drawback ofthis glove type is that they are constructed from float sheets and the seams are welded. Manual dexterity is reduced withthese gloves. Neoprene and nitrile gloves are chemically similar to latex gloves, but have the advantage of having a better resistance to solvents than latex gloves. They are slightly more expensive than latex. Polyurethane gloves are strong, very thin, quite inflexible, and expensive. Theymaybemanufacturedwithmicroporousmaterial for bettercomfort,orwithcarbonin the formulationwhichmakesthem conductive. PVA gloves are resistant to strong acids and solvents, but not water in which they are soluble. They are expensive.

272

and

Masks

Gloves

Gore-Tex gloves have welded seams and are hypoallergenic. They are breathable because of their porous membrane. They are expensive. Special gloves are used in cleanrooms for heat resistance or insulation and usually made from polymers of silicone, or Kevlar. They are generally not made for cleanroom use and, when used in cleanrooms, they should be cleaned thoroughly and their contact with contamination-sensitive material minimised. Kevlar gloves havea special problem because of their fibrous nature. Other polymers,such a butylrubber,areoccasionallyusedtomake gloves for use in cleanrooms. Carefulevaluation of thecleanlinessof these products must be done before accepting them for use.

20.2.4 Testing of Gloves Information on the properties of gloves and methods used to test gloves is given in the Institute of Environmental Sciences Recommended Practice, RP CC005. Tests forsurfacecleanlinessincludethemeasurementof particles, non-volatile residues and ions. Particle counting involvessubmerging a sample in a quantity of particle-free water, and shaking on an orbital shaker for a given time. The water from the sample is then analysed for particles, either by use of a liquid particle counter, or microscopically. Measurement of the non-volatile residue involves submerginga sample in a suitable solvent, at a given temperature, for a given period of time. The sample is removed and the weight of the residue from the evaporated solvent measured. Ionic content is measured by submerging a sample in deionised water for a period of time then measuring the ion content of the water. Other tests include chemical resistance and compatibility; strength and accelerated ageing of thebarriermaterial;staticcharge;permeability resistance to liquids;contacttransfer;outgassing,andheatresistance. These are detailed in IEST -RP-CCOOS. It may be necessary to ensure that gloves are not punctured after use. There are simple methods available for checking tears and holes in gloves. The used glove can be filled with water and checked for leaks. The glove

Cleanroom Technolopy

273

can also be blown up with air (by mouth is sufficient), closed at the cuff, and squeezed; any leaks can be found by passing the glove close to the cheek.

Acknowledgements Figures 20.1 and 20.2 arereproducedbypermission of theAmerican AssociationfortheAdvancement of Science. I shouldlike to thank DouglasFraser of theProteinFractionationClinicforposingforthe photographforFigure 20.3 andMichaelPerryofAnalogDevicesfor posingforthephotographsinFigures 20.4 and 20.5. Figure 20.6 is reproduced by permission of Pentagon Technologies.

Cleaning a Cleanroom 21.1 Why a Cleanroom Must be Cleaned Cleanrooms are used to protect the products of many industries from contamination. Millions of pounds or dollars, as well as years of effort, can be put into designing and constructing a cleanroom, but little thought and effort may go intokeeping the room clean. It may be asked, ‘Why does a cleanroom need to be cleaned. Is it not supplied with large quantities of particle and bacterial-free air, and do not workers wear special cleanroom clothing to prevent dispersion of contamination’? In fact, cleanroom clothing, as has been discussed in Chapter 19, does not stop dispersion and a person can disperse, when wearing cleanroom clothing, over 100 000 particles 2 0.5 pm and over 10 000 particles 2 5.0 pm. Machines also disperse millions of particles. Many of the larger particles will easily settle, by gravity, onto horizontal surfaces. Other smaller particles are thrown from the air stream, or deposited by Brownian motion, onto surfaces. Dirt can also be brought into a cleanroom through foot-borne transfer. Cleanrooms surfaces get dirty and must be cleaned. If they are not, contamination is transmitted to the product when it comes into contact with the dirty surfaces; it can also be transferred by personnel touching a cleanroom surface and then the product. Cleanrooms can appear to be clean but can, in terms of cleanroom requirements, be very diky. The human eye will not see a particle much smaller than 50 pm. Small particles will eventually be seen when their concentration builds up and agglomeration occurs. When this happens, a cleanroom is long past being acceptably clean.

276

Technology

Cleanroom

People can also disperse hundreds, or thousands, of microbe-carrying particles per minute. Because these micro-organisms are carried on skin cells, or fragments of skin cells, their average equivalent diameter is between 10 pm and 20 pm. These settle easily, by gravity, onto surfaces in the room. In cleanrooms, such as those used by the healthcare industry, the room must bedisinfected to kill the micro-organisms.

21.2 Cleaning Methods and the Physics of Cleaning Surfaces The main force that holds particles to cleanroom surfaces is the Londonvan der Waal’s force, this being an inter-molecular force. Electrostatic forces can also attract particles to a surface. The importance of electrostatic forces will vary between cleanrooms, and depends on the type of materials used within the cleanroom. A third force can arise after wet cleaning. Particles that are left behind will dry on the surface, and may adhere to it through a bridge of material that has dried out from the liquid left behind. If aqueous solutions are used for cleaning then particles that are watersoluble will be dissolved. If solvents such as alcohols are used, then organic materials are dissolved; these particles can then be removed in solution. However, the majority of particles found in a cleanroom cannot be dissolved, and the adhesive force that holds particles to a surface must be overcome. Immersing the particle in a liquid, as occurs in wet pick-up vacuuming, damp wiping or mopping, may dissolve the particle bridge left after drying. If an aqueous-based detergent is used then the London-van der Waal’s force and electrostatic forces can be reduced or eliminated. The particle can then be pushed or drawn off from a surface by wiping, mopping or vacuuming. The methodsthat are generally used for cleaning a cleanroom, are: Vacuuming (wet or dry) Wet wiping (mopping or damp wiping) Picking-up with a tacky roller.

The efficiency of these cleaning methods dependson the surface being wiped. If the surface finish is rough or pitted then it is more difficult to remove particles situated within these surface blemishes. Thus it is necessary, as discussed in Chapter 8, that the inner surfaces ina cleanroom should be smooth.

21.2. l Vacuuming There are two types of vacuuming used to clean cleanrooms: dry and wet. Dry vacuuming depends ona jet of air moving towardsthe vacuum nozzle and overcoming the adhesion forces of particles to the surface, and hence detaching them from a surface. However, an air velocity cannot be generated that is sufficient to remove small particles. Figure 2 1.1 is a graph ofresults I obtained to show the efficiency of dry vacuuming against different sizes of sand particles on a glass surface.

0.5

1 ,O

5.0

10.0

50.0

Particle s i z e (pm)

Figure 21.1 Efficiency of dry vacuuming

100

200

278

Technology

Cleanroom

A nozzle of an industrial vacuum was pushed along a surface covered with particles. It may be seen that most of the particles over 100 pm are removed, but smaller particles are inefficiently removed, and at a size of 10 pm only about 25% are removed. This experiment shows that the majority of particles on surfaces are not removed by dry vacuuming, and domestic experience confirms this. How many people would be content to only vacuum a vinyl floor? A light-coloured kitchen floor would, in a very short time, be in an unacceptable condition.

Water and solvents have muchhigher viscosity than air, so that the drag forces exerted by liquids on a surface particle are very much greater. Therefore, if a wet pick-up vacuum system is used, the additional drag forces will substantially increase the collection efficiency.

21.2.2 Wet wiping Wet wiping, with wipers or mops, can efficiently clean cleanroom surfaces. The liquid used allows some of the particle-to-surface bonds to be broken and particles to float off. This is especially true if a surfactant is used. However, many particles still adhere to the surface, and the mop or wiper’s fibres are necessary to push and detach the particles. The particles that are removed are retained in the wiper. A damp wiper is more efficient than a dry one, as the drag forces in the aqueous solution or solvent are much greater. Some wipers and mops are more efficient than others. As they work by pushing and dragging particles, a wiper or mop made from a fine fibrous material will be moreefficient that a solid block ofmaterial.

21.2.3 Tacky rollers The particle removal efficiency of ‘tacky’ rollers is dependent on the strength of the adhesive force of the roller’s surface. The greater this force, the more particles that are removed. Other factors, such as the surface softness of the roller, which allows better contact with the particle’s surface, will also influence the removal efficiency.

279

Cleaning

21.3 Implements Used to Clean Cleanrooms The implements used in cleanrooms have a similarity to those used in cleaning the home. However, there are important differences. For example, a dry brush should never be used to sweep a cleanroom. I found that they can produce over 50 million particles 2 0.5 pm per minute. String mops arenot much better, as they can produce almost 20 million particles 2 0.5 pm per minute.

21.3.2 Dry and wet vacuum systems

Figure 21.2

Vacuum system being used in its wet pick-up mode

280

Technology

Cleanroom

Dry vacuuming is a popular method of cleaning because it is relatively inexpensive and, because no cleaning liquids are needed, no contaminants are introduced into the cleanroom. However, unfiltered exhaust-air must not pass into the cleanroom. This is achieved by using either an external central-vacuum source, or providing a portable vacuum’s exhaust air with a HEPA or ULPA filter. This filter must be placed after the motor to ensure that no particles from the motor are dispersed into the room. A wet vacuum or‘pick-up’ system is more efficient than a dry vacuum system becauseof the additional drag forces from the liquid used. It is also generally more efficient than a mopping method,as there is less liquid left to dry on the floor, and hence contaminate it; this also means that the floor will also dry quicker. Figure 21.2 shows a cleanroom vacuum system being used in its wet pick-up mode to clean a cleanroom floor. Wet pick-up systems are used on conventionally ventilated cleanroom floors, but may not be suitable for the pass-though type of floor used in the vertical unidirectional system.

21.3.2 Mopping systems Cleanrooms are often cleaned with a mop and bucket. Household string mops should not be used as they contribute a large amount of contamination. Squeezy-typespongeand other synthetic mops used in the home contribute less contamination when new,but break upthrough use. Two types of cleanroom mopsare shown in Figures 21.3 and 21.4. The cleaning surfaces of these mops are made from materials that do not easily break up. This can be made froma PVA or polyurethane open-pore foam, or a fabric such as polyester. The compatibility of the material to sterilisation, disinfectants and solvents should be checked, as some materials are not suitable. Buckets should be made fromplastic or stainless steel. A cleanroom can be cleaned and disinfected by use of a mop and a bucket containing water with detergent, or disinfectant. However, the level of cleanliness achieved by this system may not be sufficient for some cleanrooms, as the dirt taken from the floor is rinsed out into the bucket and reapplied to the floor. Experience in the home tells us that it does not take long before the detergent solution is dirty and the floor is not being cleaned properly.

Cleaning

28 1

Figure 213 Cleanroom mop suitablefor cleaning surfaces such as walls

Figure 21.4 Cleanrooms mop suitable for floors

When disinfectants are used, especially chlorine-based ones, the soil contamination may neutralise the disinfectant’s effectiveness. Continual changing of the solution in the bucket overcomes this problem, but a substantial improvement can also be madeby use of a ‘2 or 3-bucket’ system. Figure 21.5 is a photograph of 2-bucket and 3-bucket’ systems.

Figure 21.5

Two and three bucket systems

Figure 2 1.6 shows a diagram of a method I suggest for the 2- or 3- bucket system. As can be seen, the cleaning or disinfection starts with the mop being dipped into the active solution. The mop can, if thought necessary, be squeezed free of excess liquid. The liquid is then spread onto the floor

and the floor wiped, or disinfected (stage 1). The mop is then wrung fiee of much of the dirty water collected in the mop (stage 2), dipped, and rinsed in the clean water (stage 3). The mop is again wrung fiee of excess liquid (stage 4) dipped into the active solution (stage 5), and is then ready to carry out the same cycleagain (stage 1). I f a 2-bucket system is used, one bucket is filled with active solution and the otherwith clean water, although an alternativeis to use thesecond bucket for collecting waste liquid. However, the 2-bucket system is not as efficient asthe 3-bucket system.

WI

Figure 21.6 How to use a three-bucket mopping system

21.3.3 Wipers Wipers are dampened with a detergent or disinfectant solution and used in cleanrooms to wipe surfaces and remove contamination. They are also

284

Technolopv

Cleanroom

used to wipe contamination from products produced in the room and used dry to mop-up liquids that may have been spilled. Normal household wipers are not acceptable in cleanrooms as they have a high concentration of particle, fibre and chemical contamination that is left on the surfaces they clean. The choice of wipers depends on the contamination problems in the cleanroom. There is no perfect wiper that removes all contamination from a surface; the selection of a wiper is a compromise. Knowing the use the wiper has to be put to, the importance attached to its properties, and the cash available, the best wiper can be selected for the job. Theproperties of wipers that should be considered are as follows. 21.3.3.1 Sorbency Sorbency is an important property of wipers. Wipers are often used to

mop up a spillage andother similar tasks. It is therefore necessary to know the wiper’s sorbency; both its capacity (the amount of liquid it can sorb) and its rate (how fast it can sorb liquid). This property is also important in terms of contamination control, as a wiper with good sorbency will ensure that less contamination is left on the surface than one with poor sorbency; if a cleanroom surface is wiped and little liquid left, then there will be fewer particlesleft. 21.3.3.2Wipercontamination

Cleanroom wipers are one of the dirtiest items in a cleanroom. Compared to wipers used in the home they are clean, but a single wiper can contain many times more particles than all the air in the room. It is therefore necessary to choose a wiper that is low in particles. Attention should also be paid to the edges of the wiper as raw edges can contribute to fibre and particle contamination. When a wiper is wetted, any material within the wiper that is soluble will dissolve. This may then be transferred onto the surface being wiped. Materials that can be extracted by water, or solvents, are known as ‘extractables’. Extractables of particular interest in the semiconductor industry are metallic ions. When this is important the amount and type of extractables in a wiper can be usedto determine the best wiper for the job.

21.3.3.3 Other properties of wipers Other properties that should be considered are: 0

0 0

0

textile strength abrasion resistance static (or antistatic) properties sterility.

All of the above properties of wipers can be evaluated by the tests suggested in the IEST RecommendedPractice RP CC004.

21.3.4 Tacky rollers Tacky rollers are similar in size and shape to paint rollers used in the home, but they have a tacky material around the outside of the roller. An example of a tacky roller is shownin Figure 2 1.7.

Figure 21.7 Tacky roller

286

Technology

Cleanroom

The roller is rolled over a cleanroom surface and particles adhere to the roller’s tacky surface.

21.3.5 Floor scrubbing systems Floor scrubbing machines that use rotary brushes are available for cleanroom use. The machine has a skirt around the outside of the brushes and an exhaust system that removes particles produced by brushing the floor. A high efficiency filterthen filters thisexhaust.

21.4 Liquids Used in Cleaning Cleanrooms 21.4.l Cleaning liquids The ideal cleaning solution for a cleanroom is one that has the following properties: 0 0 0 0 0 0 0

non-toxic to people non-flammable fast drying, but not unreasonably so not harmfil to cleanroom surfaces leaves no contamination that is harmful to the product effective in removing undesirable contamination reasonablypriced.

No product is satisfactory in all of the above aspects. For example, ultraclean water has many of the listed properties but can corrode certain surfaces and, without the additionof a surfactant, it is relatively ineffective in cleaning. Some organic solvents also come close to the ideal, but can be flammable, toxic and expensive (consider the toxicity, fire danger and cost of cleaning awhole room with a solventsuch as ethanol). The choice of a cleaning agent will be a balanced compromise, the choice being dependent on its properties and required use. To assist in the correct choice, knowledge of the properties of the cleaning solution must be considered.

Cleaning

287

The toxicity, flammability and boiling point properties of various solvents are available from the suppliers of solvents, and these will assist in the choice of a suitable solvent. Also available is information on the effect solvents have on materials. Important in the context of cleaning cleanrooms is its effect on plastics, some of which are very vulnerable to solvents. Because of their toxicity and flammability it is difficult to find a good choice of solvent. The demise of CFCsbecause of environmental problems has added to the problem. Alcohols are often used, especially when combined with water to reduce the flammability of the alcohol and increase their disinfection properties. Cleaning is often carried out by water containing a surfactant. However, cleaning agents in their household form are often combined with chemicals such as perfumes, sodium chloride, sodium carbonate, sodium meta silicate, tetra-potassium pyro-phosphate, formaldehyde, etc., and the choice of such surfactants may be a mistake. Cleaning agents which are chemically less reactive are best. Surfactants have a hydrocarbon water-repellent (hydrophobic) group and a water-attracting (hydrophilic) group. They can therefore be divided into four groups, depending on whether the hydrophobic part of the molecule is anionic, cationic, amphoteric or non-ionic. These are illustrated in Figure 20.8. The surfactant of choice for cleaning a cleanroom is usually non-ionic, as these are the least reactive of the four types of surfactant and do not contain metallic ions. ,4nionic surfactants usually contain metallicions (usually sodium), but it is possible to manufacture them with organic bases and hence avoid the problem of metallic ions. These anionic compounds will, however, still be reactive. Finally, some thought must be given to particle contamination. When the detergent solution or organic solvent dries, unacceptable particle contamination must not result. These solutions must be therefore free of particles of significant size. ‘This is particularly important in critical areas close to the production points, e.g. clean benches, but of less significance in general areas away from the production, e.g. walls, doors and floors.

288 (1)

Technology

Cleanroom

Anionic,e.g.Sodiumdodecyl sulphate CH3CH2(CH2),CH2 0 SO,(-)Na(+)

(2)

Cationic,e.g.Benzylalkoniumchloride

(3)

Amphoteric, e.g. Alkyldimethylbetaine

(4)

Non-ionic,e.g.Dodecylalcoholethoxylate

Figure 21.8 Surfactant compounds

21.4.2 Disinfectants Disinfectants are used in bioclean rooms to kill micro-organisms on surfaces. Similar problems to those foundin cleaning solutions exist with disinfectants, and some that are very efficient in killing micro-organisms may not be the product of choice in a cleanroom. It is very difficult to produce a disinfectant that is highly toxic to a microbial cell but not the human cell. It is generally found that these two properties go hand-in-hand and the fewdisinfectants that are effective against microbes, but not toxic, are expensive. It may be useful to select the expensive, least-toxic, solutions for around the critical area where the product sits, but to use less ex-

pensive chemicals in general areas such as floors that are away fiom the product. Table 2 1.1 summarises someof the properties of commonly useddisinfectants. It may be seen from this table that there is no perfect disinfectant. Generally speaking, phenols, pine oils and chlorine-release compounds are less suitable in critical cleanroom areas because of their toxic properties, and iodophors because of their corrosive and staining properties. However, this statement is a general one, as each of the categories in the table contain a spectrum of activity that is greater or lower than indicated, and both phenols and chlorine-releasing compounds are used successfully in cleanrooms. Chlorine-release compounds are a particular problem. They will kill spores, which are generally not killed by other acceptable disinfectants. Therefore, despite being toxic and corrosive, they are usedin cleanrooms. Quaternary ammoniumcompounds (Quats), or proprietary disinfectants synthesised to optimise toxicity and disinfection, appear to have fewerproblems. Table 21.1

Properties of disinfectants

Bactericidal effect

Other properties

Type of

Gram

Gram

Disinfectant:

+ve

-ve

Alcohols

+ H + + + -No te

No

No

Yes

U+

Proprietaryeg

+t+

+No

No

No

Yes

U+

Spores

Fungi

Corrosive

Stain

Toxic

Active

Cost

in soil

+++

-

chlorhexidine Quats

W

+

-

U

YesMo

Iodophors

+t+

+++

+

++ Yes

Yes

Chlorinetype

+++

Phenols

t

Pine oils

+

t

+++

tt+

+

-

+

-

Yes

No

No

Yes

tt

No

Yes

U

+++ Yes

Yes

-

No

Yes No

Yes

No

No

No

No

Yes

+ + +

Quats = Quaternary ammonium compounds

Alcohols are suitable for cleanroom use as they have good bactericidal properties and evaporate to leave practically no residue. The use of 60% or 70% ethanol in water, or 70-100% iso-propanol, is particularly recom-

290

Technolopy

Cleanroom

mended at the point ofproduction, where a minimal carry-over of chemicals is desirable. Incorporation of chlorhexidine, or a similar disinfectant, into the alcohol will increase its effectiveness as a bactericide. The use of a disinfectant such as an alcohol, or an alcohol combined with a proprietary bactericide should beconfined, by reasons of expenseand fire risk, to the critical area. An aqueous solution of quaternary ammoniumcompounds, or a phenolic compound, could be used to disinfect the rest of the cleanroom. Washing surfaces with a simple detergent solution that is free from disinfectant is an effective way ofremoving most of the micro-organisms on hard surfaces (over 80% efficient). However, the addition of disinfectants will reduce the microbial counts by over 90%, and will be necessary to prevent bacteria growing in the washing materials and cleaning solutions left in buckets. If this is not done, subsequent cleaning will spread the bacteria around the cleanroom.

21.5 How Should a Cleanroom be Cleaned? The methods used to clean cleanrooms will vary according to the standard of cleanliness ofthe room and its layout. It is therefore necessary to tailor thecleaning method to the cleanroom.The following information may assist this. It is also useful to consult the IEST RP CCO18: ‘Cleanroom housekeeping - operating andmonitoring procedures’.

21.5.1 General points Thefollowing general points shouldbe considered whendeveloping cleaning method:

a

If you can see any dirt in a cleanroom it is neither a clean room nor a cleanroom and must be cleaned. It must be explained tothose cleaning the room that they are removing particles or micro-organisms that cannot be seen. Although the cleanroom may look clean it still requires thorough and systematic cleaning.

Cleaning

29 1

Cleaning a cleanroom can generate many particles. To minimise contamination generated by the cleaning process the air conditioning should be fully on. Cleaning staff should have the same standard of clothing and gloves as the production staff. Cleaning must be done slower than would be the case in the home. This will minimise dispersion and ensure more efficient cleaning. Cleaning agents may be diluted in a bucket with distilled or deionised water, or with water as clean as can be provided. Bottles with spray nozzles are used to apply a cleaning agent or disinfectant. However, tests I carried out showed that they release over 1 million particles 2 0.5 pm with every spray. It is therefore best to cover the spray nozzle with the wiperwhen applying the solution. Dispensing by a hand pump isprobably a better alternative. Cleaning or disinfectant agents used in the ‘critical’ area should be chosen to do the least harm to the product and be at the lowest concentration to dothe job effectively. Diluted detergents can support microbial growth, so cleaning agents should be prepared freshly from the concentrated solution and then stored for the minimum time. Containers used for handling the diluted agent should not be left about and continually topped up, as there may be bacteria growing in the container. Containers should be thoroughly washed out after use and left to dry.

21.5.2 Cleaning methods with respect to area type When setting up a schedule for cleaning a room, consider the fact that horizontal surfaces, because of gravitational settling of particles, will become dirtier more quickly than vertical surfaces. Also surfaces that come into contact with people will become dirtier than those that do not. This means that walls and ceilings do not collect as many particles and require less cleaning than floors or doors. Doors will need more cleaning than walls because they are touched more often. Cleaning should be considered in relation to the ‘critical’, ‘general’ and ‘outside’ area concept. The ‘critical’ area is the production zone where contamination can gain direct access to the product. These

292

0

Technology

Cleanroom

critical areas should be cleaned to the highest level. The ‘general’ area of the cleanroom is where contamination cannot directly contaminate the product, but it can be transferred to ‘critical areas’, e.g. walls, floors, etc.The cleaning there can therefore be less stringent. The ‘outside’ area is the materials air lock, clothes changing and other ancillary areas. The cleaning method here can be less strict, although becauseoftheextra activity itmaybe necessary todo it more frequently. The most efficient cleaning methodsshouldbeused in the critical area, less efficient methods in the general area, and the least efficient in the outside areas. This means that the surface area that canbe cleaned in a giventime shouldbe smallest in ‘critical’ areas and greatest in ‘outside’ areas. There is an overlap in the efficiency of cleaning methods but, generally speaking, the cleaning efficiency increases as follows: Dryvacuuming

single-bucket mopping =. multiple-bucket

mopping 3 damp wiping or, wet pick-up 0

0

Dry vacuumcleaning incleanroomsshould not bethought ofas a cleaning method,but as a pre-requisite to cleaning. It is generally used in outside and general areas and in critical areas that have a fast buildup of fibres or particles generated by the process. Cleaning methods vary, but in outside areas single-bucket mopping may be suitable. In general areas multiple-bucket mopping or wet pick-up canbeused and in critical areas, damp wiping. Cleaningofthe ‘critical’ areas should be done frequently. The idea thatcleaning should be done only by designated cleaning staff is wrong. Personnel working in the cleanroom may be required to clean at times throughoutthe day, e.g. prior to the start of producing a fresh batch. Outside areas, owing to the fact that they are the furthest away from the area where the product is exposed to contamination could, if all other factors were equal, be cleaned less often. However, because of the high activity and debris accumulated in the change areas, it may be necessary to clean them on a more regular basis than other areas of

Cleaning

293

the cleanroom. ‘General’ areas should be cleaned at a frequency dependent on the standard of the cleanroom but can probably be done, prior to, or just after, the work period. This can be done either by the staff working in the room, or by contract cleaning staff. Where there is 24 hour working, cleaning must be done during production. This is less than satisfactory, but there may be no option. It may be possible to stop production in the surrounding area and cordon it off. This can stop people slipping on the wet floor.

21.5.3 Cleaning methods The cleaning process can start byremoving the ‘sticks and stones’ with a dry vacuum. Fluff, fibres, glass splinters, etc. are removed but not small particles. It also removes sufficient soil to allow a lower concentration of detergent to be used. If the vacuum fails to lift large items they should be gathered together with a wet mop and removed. Cleaning should start at the areas furthest away from the exit. This ensures minimal recontamination of the surfaces. In a critical area in a unidirectional flow of air it is best to start at the point nearest the supply filters and move away from them. Attention should be paid to the cleanliness of the water. In ‘outside’ areas that are cleaned using a single bucket, it is generally accepted that the water should be changed when it becomes noticeably discoloured. If a three or two-bucket system is used in ‘general’ are as the water should not be controlled by discolouration but changed after a given surface area is cleaned. Use overlapping strokes of the wiper or mop. A cleanroom will always appear clean to the eye and it is not easy to ensure that every piece of the surface is cleaned, except by an overlapping pass method. If a damp wiper is used then it should be folded, and as the cleaning proceeds it should be refolded to give a clean surface. After all surfaces of the wiper are used it should be replaced. The area to be cleaned in a given time must be determined. Precision cleaning at the critical area is done very slowly, while, on the other hand, it should be possible to mop over an ‘outside’ area at a greater speed.

294

0

0

Cleanroom Technology

If disinfectants are used in an aqueous form, it must be remembered that they do not act instantly. Disinfectants should be applied liberally to ensure that they do not dry off and should be left for at least two minutes, and preferably five minutes, to act. Alcohol, with or without bactericides, will dry quickly. This is permissible, as it partly depends on the drying of the alcohol to kill the bacteria. In ‘critical’ and sometimes ‘general’ cleaning, the process is sometimes completed by going over the surface with ‘clean’ water so that any residual surfactant or disinfectant is removed. This is especially usefil with a single bucket system. In critical cleaning, the process can be finalised by vacuuming over the surface. This will ensure that any fibres left from wipers or mops are removed.

Figure 2 1.9 is a suggested method for cleaning the ‘outside’ and ‘general’ areas in a cleanroom. The method assumesthat a single bucket is used, but a multiple-bucket method is best for a ‘general’ area.

‘clean‘ water

exhaust

METHOD

Vacuum area to remove large particles, fibres and scraps

Dip mop into cleaning solution

I

Mop over surface using overlapping passes

Wring and dip into cleaning solution and mop again

Figure 21.9 Routine cleaning of ‘outside’ and ‘general’ areas

Cleaning

295

I solution

PRODU RC ET QS UIRED

I

Wiper

with

3 FqG I METHOD

Step 1

Fold and dampen wiper

Optional

Step 2

Wipe surface with overlapping passes

Refold wiper to clean wipe surface, and wipe or dry surface

Wipe with clean water and/or vacuum

Figure 21.10 Cleaning of critical areas

Figure 2 1.10 shows a suggested method for ‘critical’ areas. A vacuum is not normally required but can be used as a preliminary step where the process disperses large numbers offibres or large particles.

21.6 Test Methods In the home, it is relatively simple to see if your cleaning has been unsuccessful; a look will be sufficient. In a cleanroom, dirt should never be seen, even if the cleaning has been less than successful. There are, however, a number of methods that can be used to ascertain the effectiveness of cleanroom cleaning. Some of these methods are used to establish how quickly cleanroom surfaces become soiled; this information can then be used to establish how often the surface should be cleaned. Other test methods are used to establish how much contamination is on the surface

296

Technolopy

Cleanroom

before and after cleaning, and hence, how efficient the cleaning has been. These are as follows: 1. Inspection of the cleanroom mats at the entrance to the cleanroom can sometimes be revealing. Footprints should be seen leading into the cleanroom but never out. 2. If a damp black or white wiper is drawn over a given area of cleanroom surface it is sometimes possible to concentrate the soil sufficient to indicate the amountof dirt on the surface.

3. An ultra-violet light shows up surface particles and fibres that fluoresce. For example, fibres from cleanroom garments will show up. 4. A high-intensity light shone at an acute angle to the surface, in a darkened room, showsup small particles and fibres. 5. Sticky tape can be applied to a surface and then removed. The particles stripped from the surface can be counted and sized under a microscope. ASTM E 1216-87 outlines such a method. 6. Instruments are available for measuring particles on surfaces. A Sampling head is pushed over the surface and an optical particle counter measures the particles detached by the instrument. 7. A 47 mm diameter membrane holder, without the membrane support grid, can be attached to a particle counter and particles over a given area vacuumed off andcounted. Further information about test methods is available in IEST-RP-CC018. If the efficiency of disinfection methods is required then either a contact plate or swab can be used with neutralisers against the disinfectant incorporated in the microbial media. Microbiological surface sampling methods are discussed in Chapter 14.

Acknowledgements Figure 21.2 is reproduced by permission of Tiger-Vac. Figures 21.3 and 2 1.4 are reproduced by permission of Micronova Manufacturing. Figure 21.5 is reproduced by permission of Shield Medicare. Figure 21.7 is reproduced by permission of Dycem Ltd.

Index Page numbers in italic signify references to figures, while page numbers in bold, denote references to tables.

A2C2-Journal of Advancing Applications in Contamination Control 47-8 aerosol test challenges 144-5 agar contact strips 174, I74 air changes per hour calculation 80 air filtration classification 11 1 efficiency curve 108,109 filter housings 112, 113 filter types 103 construction 104-6,104,105,106-7,106 leak repair 15 1 particle removal mechanisms 106-9, 106, 107 testing 109 aerosol test challenges 144-5 artificial smoke 145-7 European Standard 1 10-1 1,111 IEST Recommended Practice 1 10 installation leak test 118, 141-51 military standard 109 probe (scan) testing 1 1 1-12 scanning methods 149-50,149 sodium flame test 1 10 unidirectional flow rooms 150-1 air flow air quantities 1 2 3 4 differential pressure tests 127-30 measuring with an anemometer 125-6, 126,127 measuring within a cleanroom 124 control 133-9

conventionally ventilated cleanrooms5-6, 5 testing 151 testing 1 18 turbulently ventilated cleanrooms57-62, 58, 61 unidirectional flow cleanrooms 6, 6, 17-19, 17, 18 testing 150-1 visualisation 134 smoke/particle streams 135-7, 135, 136 streamers 134-5, 134 air quality 116 air showers 66 air supply for turbulently ventilated cleanrooms 55-7 air velocities 72-3, 80 through filters 106 testing 137-9, 138 airborne cleanliness equation 56 ‘alert’ and ‘action level’ monitoring 189 allergies 194-5,269 ancillary cleanrooms 63 clothing change area63-6, 64 materials transfer area 66 anemometers 125 thermal type 126-7,127 vane type 125-6,126 antisepsis 9, 11 artificial smoke cold-generated oils 145-6 hot-generated smokes 146-7, 146 bacteria, incubation 168 ‘ballroom’ cleanrooms 77-9, 77 body voltage 262 British Standards Institution(BSI) 40 cabinets, containment 68-9, 68 Charnley, Professor Sir John 13 Charnley-Howorth ‘greenhouse’ 13-15,13,14

clean air devices l8 isolators and minienvironments 83-9, 83, 84, 86, 88, 89 semiconductor fabrication83-5, 83, 84 unidirectional 81, 82 cleaning procedures 290 cleaning liquids286-8 disinfectants 282,288-90, 289 general points29&-1 methods 276-7,293-5 area types 29 l--3 floor scrubbing systems286 mopping 280-3,281 tacky rollers278,2854,285 vacuuming 277-8,277,279-80,279 wet wiping 278 wipers 283-4 necessity for275-6 testing 295-6 cleanroom technology7-8, 7 Cleanroom Technology48 cleanrooms applications 3 classification standards basis 22-3 history 21-2 conventionally ventilated5 4 5 definition 1 early developments9-12 need for 2-5 standards EU GGMP 30--2 FDA guidelines 33-5 Federal Standard 20921,22-3,24,24 I S 0 Standards 1,21,22-3,26-9,27,28, 115-16, 121 types 5-7 unidirectional flow ventilated 6, 6, 17-1 9, 27, 18 CleanRooms 48 clothing, specialised 2, 209

300

antistatic properties26 1-2, 262 changing frequency 255,255 changing into 10-20 2 change areas 63-6,64,94 choosing 249-5 1,250,251 comfort 251-2 construction 249 design 245,246,247 early developments 15, 16 effect of wear 256 fabrics 2 4 6 4 , 2 4 8 , 2 5 7 , 2 5 9 4 0 face masks 263,266-8,266,267 gloves 269-73 half suits86, 89 historical developments237-8 particle dispersal 257-8,259,260, 275 particle generation 56 powered exhaustheadgear 268,268 processing 252-5,253,254 storage 65, 65, 221 testing 256-60, 258 construction materials 1, 8, 15, 16 ceilings 99,100 conventional building techniques 93-5 doors and windows 98 floors 98-9 general requirements9 1-3 modular construction 95-7,96,97 outgasing and electrostatic properties 100-1 surfaces 92,93-5, 98-9 turbulently ventilated cleanrooms 62 containment cabinets68-9, 68 containment rooms 67-9,67,92 contamination control 177-8 airborne and contact routes of transfer 179-80 assessing hazards 182-5,183 construction of risk diagram180,181, I82 documentation 190-1

Index

Index

identifying appropriate control methods185-6 monitoring schedules 189-90 sampling methods .l8 6 9 , 187-8 sources of contamination 178-9 staff training191 verification and reappraisal 190 design considerations 8,7 1 air changes per hour calculation 80 air flow 57-62, 58, 61 air supply55-7 air velocities80 airborne cleanliness equation 56 ancillary cleanrooms63-6 clean air devices8 1-9 clothing change area 63-6,64, 94 construction materials 1, 8, 15, 16 ceilings 99, I00 conventional building techniques93-5 doors and windows 98 floors 98-9 general requirements9 1-3 modular construction 95-7,96, 97 outgasing and electrostatic properties100-1 surfaces 92,93-5,98-9 turbulently ventilated cleanrooms 62 containment rooms67-9, 67,92 filters 57 horizontal airflow 74-6, 74, 75 isolators and minienvironments 83-9, 83, 84, 86, 88, 89 materials transfer area 66 pressurisation 59-62, 61 semiconductor fabrication76-81, 76, 77, 78, 83-5, 83, 84 turbulently ventilated cleanrooms 53-62,54 unidirectional cleanrooms7 1-80, 72 unidirectional devices8 1,82 vertical airflow 73-4, 73, 75 diffusion 107, 108

301

3

02

Index

disciplined cleanroom operation 193, 196 air transfer 196-8 authorised personnel 193-5 behaviour 198-205 handling materials203,206 items to be excluded 196,205,2 13-14,224-5 maintenance and service personnel206-8 disinfectants 92, 205, 282, 288-90,289 documentation 208 donning gloves 16 2 doorways, disciplined usage 197-8,197,198 dust particles 3, 16

European Journalof Parenteral Services 49-50 European Union Guide to GoodManufacturing Practice (EU GGMP)30-2 classification 30 grades 31 microbial contamination 32 Failure Mode and Effect Analysis (FMEA) 177 Fault Tree Analysis (FTA) 177 Federal Standard 209 for cleanrooms, class limits 25 filters see air filtration fogger 135 Food and Drug Administration (FDA) guidelines 33 controlled areas34-5 critical areas 33-4 framed wall systems96-7 fungi, incubation 168 garments see clothing, specialised gasket leaks 142-3,142, I43 gloves 2 16,219 control of contamination 269 latex 271 manufacture 270 other polymer types 27 1-2 polyvinyl chloride (PVC) 270-1

testing 272-3 goggles 2 18 half suits86, 89 hand washing 2 14,219 Hazard Analysis and Critical Control Point (HACCP) 177-8 High Efficiency ParticulateAir (HEPA) filters 18, 57, 82, 103 construction 1 0 4 4 , 1 0 4 , 1 0 5 development 15-1 6 history of cleanrooms 9-12, 15-1 7 impaction 107, 108 industrial cleanrooms: early developments 15-1 7 gyroscope production 16,16 infiltration testing 132-3, 132 information sources 37 books 43 Federal Standards 20941 Institute of Environmental Sciences and Technology (IEST) 41,43-7 International Cleanroom Forum 1-2 5 International Confederation of Contamination Control Societies (ICCCS) 37-8 IS0 standards 38,40-l I S 0 14644 Standard 26-9,39 I S 0 14698 Standard 3 9 4 0 journals and magazines 47-50 pharmaceutical documents 50-1 pharmaceutical standards41 EU GGMP 41--2 FDA guidelines 42 Institute ofEnvironmental Sciences and Technology (IEST) 4 1 , 4 3 4 filter test l 10 Guides 47 Recommended Practices (RPs) 44-6, 110 interception 107, 108 International Confederation of Contamination Control Societies (ICCCS) 37-8 Interpharm Press 50-1

IS0 Standard 14644-l for cleanrooms 1,21, 115-1 6, 121 airborne particulate classes27 classification equation 26 concentration limits28, 57 M descriptor method 29 measurement of particle concentrations 160-2 acceptance criteria 162 sample locations 160-1, 162 sampling volume 161-2, 163 worked example 162-5 occupancy states 29

Journal of the Instituteof Environmenta ‘1 Sciences and Technology 49 ‘laminar flow’ cleanrooms 17 laundering of garments 252-5,253,254 Lister, Lord Joseph9, 11 Lister steam spray10 machinery, entry into cleanrooms233-5 ‘macroparticles’ 29 magnehelic pressure gauge 129,129 manometers, inclined 128, 128 materials choosing 223-5 construction 1, 8, 15, 16 ceilings 99, I00 conventional building techniques93-5 doors and windows 98 floors 98-9 general requirements 9 1-3 modular construction 95-7, 96, 97 outgasing and electrostatic properties100-1 surfaces 92, 93-5,98-9 turbulently ventilated cleanrooms 62 external sources 225-6 transfer into cleanroom 228 bench area 229-32,229,230,231

benchless area 232-3,233 hatches and sterilisers 2 3 5 4 , 2 3 5 wrappings 2264,227,229-3 I , 229,230,231 Micro Magazine 48-9 microbial counts 167 air sampling 167-8, 169 calculation of likely airborne contamination172 centrifugal samplers 170,I70 impaction onto agar 168-71,169 inertial impaction samplers168-9 membrane filtration 170, I71 settle plates 171-2 surface deposition171-2 personnel sampling 175 surface sampling 173 contact sampling 173-4, 173 swabbing 174, .l75 micro-organisms 4 dispersion routes244-5 sources 2 4 3 4 , 2 4 4 monitoring see testing and monitoring cleanrooms Most Penetrating Particle Size (MPPS) 1 10 ‘no touch’ techniques199-203,200,201,202,203,204 operating theatres4 , 4 historical developments9-15, IO, 11, 12, 237-8 ventilated 12-1 5 operation of cleanrooms 8 Parenteral Society 51 particles concentration 26,27,28 diameters 23 dispersion from mouth 263,263-5,264,265 measuring 153 acceptance criteria 162 continuous monitoring 156-8

I S 0 14644 standard 160-5 occupancy states 158-60 photometer 147-8, 148 sample locations 160-1, 162 sampling volume 161-2, 163 scanning methods 149-50,149 single particle counters 148-9, 153-5, 154, 155 removal mechanisms 106-9,106,107 shedding rates 198-9, 199,238,239,243 sources and dispersion238-9 cleanroom clothing24 1,242 mouth and nose 242 ordinary clothing240,241 skin 2 3 9 4 0 , 2 4 0 tests 118 transfer routes242-3 pass-over benches 64,64 PDA Journalof Parenteral Science 50 personnel 209-1 0 changing into cleanroom garments 210-1 1 approaching pre-changezone 2 1 1-13,211 changing zone 15-1 2 7 entrance zone 217-20 pre-change zone 2 13-1 5 exit procedures220-1 general hygiene 194-5,2 10 training 191, 193, 195, 198-205, 206-7 pharmaceutical cleanrooms 30 EU GGMP Standard 30-2 FDA guidelines 33-5 photometers 147-8, 148 Pitot-static tube 124 pressurisation 91-2 differential pressure tests127-30 turbulently ventilated cleanrooms 59-62, 61 puffer and smoke tube136,136 reason to exclude certain personnelfrom cleanrooms 194-5

Index

307

Replicate Organisms Detection and Counting (RODAC) dishes 173, 173 risk assessment for contamination 183-5, 183 risk diagrams 180, 181, 182 Sandia Corporation 17-19,21-2 screening 107, 108 semiconductor fabrication 4 ‘ballroom’ cleanrooms 77-9, 77 contamination 3 , 4 minienvironments 83-5,83,84 unidirectional cleanrooms 76-81, 76, 77, 78 sequential monitoring systems 156, 156 shoe cleaners 211,212-13,212 simultaneous monitoring systems 156, 157 single particle counters 148-9, 153-5, 154, 155 smokelparticle streams 135-7, 135, 136 cold-generated oils 145-6 hot-generated smokes 1 4 6 7 , 1 4 6 measuring penetration photometer 147-8,148 single particle counters 148-9 polystyrene latex spheres 147 staff see personnel standard deviation 164 Standard Mechanical Interface Format (SMIF) 84, 85 sticky mats 212,212 streamers 1 3 4 5 , 134 studless wall systems 95-6 surfactants 287, 288 t-factors 165 tacky rollers 278,2854,285 testing and monitoring cleanrooms 8, 1 15-1 6 aerosol test challenges 144-5 air quantities and pressure differences 123-30 airflow 133-9,138 artificial smoke 145-7 compliance monitoring 121-2 containment and leak testing 131-2

infiltration 132-3, 132 filter installation leaks141-51 hazard monitoring and control 186-9,187-8 measuring smoke penetration photometer 147-8, 148 scanning methods 149-50,149 single particle counters 148-9 microbial sampling 167-8, I69 calculation of likely airborne contamination172 centrifugal samplers 170, 170 contact surface sampling 1 7 3 4 , 1 7 3 impaction onto agar168-7 1,169 inertial impaction samplers 168-9 membrane filtration 170, 171 settle plates 171-2 surface deposition 171-2 personnel sampling 175 principles 116 re-testing to demonstrate compliance 120-1, 120 room type and occupation state 119-20 swabbing 174, 175 tests 117-18, 117 toxic substance isolation 85-9,86 turbulently ventilated cleanrooms 53-5,54 air flow 57-62, 58, 61 air supply 55-7 airborne cleanliness equation 56 construction materials 62 filters 57 pressurisation 59-62, 61 Ultra Low Penetration Air (ULPA) filters57, 103, 106 ‘ultrafine’ particles 29 unidirectional cleanrooms 7 1-3, 72 air velocities80 filter testing 150-1 horizontal airflow 74-6, 74, 75 semiconductor fabrication 76-8 1, 76, 77, 78

Index

vertical airflow 73-4, 73, 75 Upper Confidence Limit (UCL) 162, 165 vacuuming 277-8,277,27940,279 validating methods 188-9 visualisation of airflow 134 smoke/particle streams 135-7,135,136 streamers 134-5, 134 Whitfield, Willis J. 17, 18, 19, 22 wipers 283-4 contamination 284 other properties 285 sorbency 284

309

Related Documents


More Documents from "JAGU"