Loading documents preview...
Samsung eNB Counter Description for SLR 4.5
Radio Access Network
Provides detailed description for statistical items collected in the Samsung LTE eNB system for data analysis.
Document Version 7.0 February 2016
Document Number: 2600-00H4OMGAT
© 2016 SAMSUNG Electronics Co., Ltd. All Rights Reserved. No part of this document may be photocopied, reproduced, stored in a retrieval system, or transmitted, in any form or by any means whether, electronic, mechanical, or otherwise without the prior written permission of SAMSUNG Electronics Co., Ltd. No warranty of accuracy is given concerning the contents of the information contained in this publication. To the extent permitted by law no liability (including liability to any person by reason of negligence) will be accepted by SAMSUNG Electronics Co., Ltd., its subsidiaries or employees for any direct or indirect loss or damage caused by omissions from or inaccuracies in this document. SAMSUNG Electronics Co., Ltd. reserves the right to change details in this publication without notice.
SNMTC-v3-0312
This manual should be read and used as a guideline for properly installing and/or operating the product. Owing to product variations across the range, any illustrations and photographs used in this manual may not be a wholly accurate depiction of the actual products you are using. This manual may be changed for system improvement, standardization and other technical reasons without prior notice. Samsung Networks documentation is available at http://www.samsungdocs.com
Contents Preface
xx Relevance ........................................................................................................................................ xx Conventions in this Document ........................................................................................................ xx New and Changed Information ...................................................................................................... xxi Revision History .............................................................................................................................. xxi Organization of This Document .................................................................................................... xxii Related Documentation ................................................................................................................ xxii Personal and Product Safety ........................................................................................................ xxiii Equipment Markings ................................................................................................................... xxvii
Chapter 1
Introduction 1 Counter Information ........................................................................................................................ 1
Chapter 2
Counter Description 3 Resource Management .................................................................................................................... 3 Resource ...................................................................................................................................... 3 Packet Statistics................................................................................................................................ 6 Ethernet Packet ........................................................................................................................... 6 Ethernet Packet per VLAN.......................................................................................................... 17 Histogram .................................................................................................................................. 20 Air MAC Packet .......................................................................................................................... 22 Air RLC Packet ............................................................................................................................ 26 PDCP Packet ............................................................................................................................... 29 PDCP Packet per PLMN .............................................................................................................. 33 Ethernet Packet (Pico)................................................................................................................ 40 Ethernet Packet per VPN............................................................................................................ 49 RRC ................................................................................................................................................. 51 RRC Connection Establishment .................................................................................................. 53 RRC Connection Reconfiguration ............................................................................................... 72 RRC Connection Re-establishment ............................................................................................. 76 RRC Connection Release .......................................................................................................... 100 RRC Connection Number .......................................................................................................... 133 RRC Connection Number per PLMN ......................................................................................... 137 RRC Connection Setup Time ..................................................................................................... 139 RRC Connection Re-establishment Time .................................................................................. 142 Call Drop .................................................................................................................................. 145 Call Drop per QCI ..................................................................................................................... 156 RRC Connection Release per QCI .............................................................................................. 171 RRC Connection Re-establishment per QCI .............................................................................. 186 E-RAB ............................................................................................................................................ 198 E-RAB Setup ............................................................................................................................. 198 E-RAB Setup Add ...................................................................................................................... 215 E-RAB Setup Time .................................................................................................................... 231 E-RAB Erase Request ................................................................................................................ 233 E-RAB Erase.............................................................................................................................. 248 E-RAB Modify ........................................................................................................................... 250 E-RAB Release Request ............................................................................................................ 265 E-RAB Release .......................................................................................................................... 268
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
iii
Contents
E-RAB Session Time per Cell ..................................................................................................... 279 E-RAB Session Time per QCI ..................................................................................................... 281 Active E-RAB Number............................................................................................................... 283 Active E-RAB Number per PLMN .............................................................................................. 285 E-RAB QCI per-PLMN rejected.................................................................................................. 291 HO EUTRAN .................................................................................................................................. 293 Intra-eNB Handover ................................................................................................................. 301 X2 Out Handover ..................................................................................................................... 345 X2 In Handover ........................................................................................................................ 372 S1 Out Handover ...................................................................................................................... 411 S1 In Handover......................................................................................................................... 448 Handover Time......................................................................................................................... 492 Outgoing Intra-Frequency Handover ....................................................................................... 498 Outgoing Inter-Frequency Handover with Measurement Gap ................................................ 559 Outgoing Inter-Frequency Handover without Measurement Gap ........................................... 620 Outgoing Handover with DRX .................................................................................................. 684 Outgoing Handover without DRX ............................................................................................ 744 Redirection by CAC ................................................................................................................... 804 Intra-eNB Handover per QCI .................................................................................................... 806 X2 Out Handover per QCI ......................................................................................................... 815 S1 Out Handover per QCI ......................................................................................................... 825 X2 In Handover per QCI ............................................................................................................ 834 S1 In Handover per QCI ............................................................................................................ 843 HO UTRAN .................................................................................................................................... 852 Inter-RAT UTRAN PS Out Handover ......................................................................................... 855 Inter-RAT UTRAN PS In Handover ............................................................................................ 864 Collect Time (Failure) ............................................................................................................... 869 UTRAN SRVCC .......................................................................................................................... 872 CSFB PS Out Handover ............................................................................................................. 880 CSFB Redirection Out ............................................................................................................... 889 PS Redirection UTRAN Out ....................................................................................................... 891 Integrated UTRAN Out ............................................................................................................. 893 CSL ................................................................................................................................................ 902 Call Fail .................................................................................................................................... 902 MRO ............................................................................................................................................. 932 MRO RLF Classification ............................................................................................................ 932 MRO RLF at RRC Connection .................................................................................................... 934 UTRAN MRO ............................................................................................................................ 936 eICIC ............................................................................................................................................. 937 eICIC ......................................................................................................................................... 937 eICIC Partnership ..................................................................................................................... 938 eICIC ABS Pattern Info .............................................................................................................. 940 GTP ............................................................................................................................................... 959 GTP Sequence Number per QCI................................................................................................ 959 GTP Sequence Number per eNB ............................................................................................... 961 GTP Forward Traffic ................................................................................................................. 964 SRB ............................................................................................................................................... 984 Cell PDCP SDU Bit Rate ............................................................................................................ 984 DRB ............................................................................................................................................... 987 Active UE Number .................................................................................................................... 987 Packet Delay ............................................................................................................................ 991 Packet Drop Rate ..................................................................................................................... 992 Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
iv
Contents
Packet Loss Rate ...................................................................................................................... 994 IP Latency................................................................................................................................. 997 RRU ............................................................................................................................................... 998 PRB Usage ................................................................................................................................ 998 Total PRB Usage .................................................................................................................... 1000 Total PRB Usage per PLMN .................................................................................................... 1007 Cell Unavailable Time ............................................................................................................ 1010 S1SIG .......................................................................................................................................... 1011 UE-associated logical S1 Connection Establishment .............................................................. 1011 S1 Connection Time ............................................................................................................... 1015 Paging ......................................................................................................................................... 1016 Paging .................................................................................................................................... 1016 Overload Protection ................................................................................................................... 1018 Denied Call by Overload Protection ....................................................................................... 1018 Power ......................................................................................................................................... 1019 Power ..................................................................................................................................... 1019 RRH RSSI................................................................................................................................. 1022 RA ............................................................................................................................................... 1024 Random Access Preambles .................................................................................................... 1024 RACH Usage ........................................................................................................................... 1026 HARQ .......................................................................................................................................... 1028 Transmission BLER ................................................................................................................. 1028 AMC ............................................................................................................................................ 1045 MIMO..................................................................................................................................... 1045 MCS ........................................................................................................................................ 1048 DL MCS ................................................................................................................................... 1104 DL LAYER ................................................................................................................................ 1110 DL Wideband CQI ................................................................................................................... 1111 DL PMI.................................................................................................................................... 1116 DL RI ....................................................................................................................................... 1119 DL-ACK-NACK-DTX Ratio ........................................................................................................ 1121 Timing Alignment ....................................................................................................................... 1123 Timing Alignment .................................................................................................................. 1123 IOT .............................................................................................................................................. 1125 Uplink IOT Level ..................................................................................................................... 1125 Load Balancing ........................................................................................................................... 1131 Load ....................................................................................................................................... 1131 Load Balancing Handover ...................................................................................................... 1134 Idle Load Balancing ................................................................................................................ 1136 Redirection by Load Balancing ............................................................................................... 1137 Load Histogram ..................................................................................................................... 1138 Message ..................................................................................................................................... 1140 RRC Message ......................................................................................................................... 1140 S1AP Message........................................................................................................................ 1144 X2AP Message ....................................................................................................................... 1151 Traffic Distribution ..................................................................................................................... 1157 Throughput Distribution ........................................................................................................ 1157 Delay Distribution .................................................................................................................. 1173 Drop Distribution ................................................................................................................... 1179 CQI Distribution ..................................................................................................................... 1182 Carrier Aggregation .................................................................................................................... 1184 Carrier Aggregation capable UEs (PCell) ............................................................................... 1184 Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
v
Contents
Carrier Aggregation Message count for Addition-Release (SCell) ......................................... 1189 Carrier Aggregation Message count for Activation-Deactivation (SCell)............................... 1199 Air MAC Packet (PCell) ........................................................................................................... 1201 Air MAC Packet (SCell) ........................................................................................................... 1205 DL Wideband CQI (PCell) ........................................................................................................ 1209 DL Wideband CQI (SCell) ........................................................................................................ 1216 Aggregate Maximum Bit Rate .................................................................................................... 1223 UE-AMBR Override................................................................................................................. 1223 KPI .............................................................................................................................................. 1224 Accessibility............................................................................................................................ 1224 Retainability ........................................................................................................................... 1228 Retainability per QCI .............................................................................................................. 1230 Integrity ................................................................................................................................. 1231 Availability ............................................................................................................................. 1233 Mobility .................................................................................................................................. 1234 Success Rate........................................................................................................................... 1240 Index ...................................................................................................................................... 1240 Connection Drop Rate ............................................................................................................ 1246 Cell Capacity .......................................................................................................................... 1247 eNB Capacity.......................................................................................................................... 1250 UE Category ................................................................................................................................ 1251 UE Category ........................................................................................................................... 1251 Appendix A Acronyms
1252
Appendix B Index Range
1255
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
vi
List of Figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Figure 28. Figure 29. Figure 30. Figure 31. Figure 32. Figure 33. Figure 34. Figure 35. Figure 36. Figure 37. Figure 38. Figure 39. Figure 40. Figure 41. Figure 42. Figure 43. Figure 44. Figure 45. Figure 46. Figure 47.
Collection Time for PacketULByte .................................................................................................. 32 Collection Time for EnbQciDLByte ................................................................................................. 32 Collection Time for PLMN0EnbQciULByte ..................................................................................... 35 Collection Time for PLMN1EnbQciULByte ..................................................................................... 36 Collection Time for PLMN2EnbQciULByte ..................................................................................... 36 Collection Time for PLMN3EnbQciULByte ..................................................................................... 36 Collection Time for PLMN4EnbQciULByte ..................................................................................... 37 Collection Time for PLMN5EnbQciULByte ..................................................................................... 37 Collection Time for PLMN0EnbQciDLByte ...................................................................................... 37 Collection Time for PLMN1EnbQciDLByte ...................................................................................... 38 Collection Time for PLMN2EnbQciDLByte ...................................................................................... 38 Collection Time for PLMN3EnbQciDLByte ...................................................................................... 38 Collection Time for PLMN4EnbQciDLByte ...................................................................................... 39 Collection Time for PLMN5EnbQciDLByte ...................................................................................... 39 RRC/E-RAB/S1 SIG Statistics Processing ......................................................................................... 51 Collection Time for RRC Connection Establishment ...................................................................... 60 Collection Time for ConnEstabFail_CpCcTo ................................................................................... 61 Collection Time for ConnEstabFail_CpCcFail (1) ............................................................................ 62 Collection Time for ConnEstabFail_CpCcFail (2) ............................................................................ 62 Collection Time for ConnEstabFail_CpCcFail (3) ............................................................................ 63 Collection Time for ConnEstabFail_CpCcFail (4) ............................................................................ 63 Collection Time for ConnEstabFail_UpMacFail (1) ......................................................................... 64 Collection Time for ConnEstabFail_UpMacFail (2) ......................................................................... 64 Collection Time for ConnEstabFail_UpPdcpFail ............................................................................. 65 Collection Time for ConnEstabFail_UpRlcFail (1) ........................................................................... 65 Collection Time for ConnEstabFail_UpRlcFail (2) ........................................................................... 66 Collection Time for ConnEstabFail_RrcSigTo ................................................................................. 66 Collection Time for ConnEstabFail_S1apLinkFail (1) ...................................................................... 67 Collection Time for ConnEstabFail_S1apLinkFail (2) ...................................................................... 67 Collection Time for ConnEstabFail_S1apSigFail ............................................................................. 68 Collection Time for ConnEstabReject_CpCcFaill (1) ....................................................................... 68 Collection Time for ConnEstabReject_CpCcFaill (2) ....................................................................... 69 Collection Time for ConnEstabReject_CpCcFail (3) ........................................................................ 69 Collection Time for ConnEstabReject_CpCapaCacFail ................................................................... 70 Collection Time for ConnEstabReject_S1apMmeOvld ................................................................... 70 Collection Time for ConnReconfigAtt ............................................................................................. 74 Collection Time for ConnReconfigSucc .......................................................................................... 74 Collection Time for SCellAddCount ................................................................................................ 74 Collection Time for SCellReleaseCount .......................................................................................... 75 Collection Time for RRC Connection Re-Establishment ................................................................. 87 Collection Time for ConnReEstabFail_CpCcFail (1) ........................................................................ 87 Collection Time for ConnReEstabFail_CpCcFail (2) ........................................................................ 88 Collection Time for ConnReEstabFail_CpCcFail (3) ........................................................................ 88 Collection Time for ConnReEstabFail_CpCcFail (4) ........................................................................ 89 Collection Time for ConnReEstabFail_UpMacFail (1) ..................................................................... 89 Collection Time for ConnReEstabFail_UpMacFail (2) ..................................................................... 90 Collection Time for ConnReEstabFail_UpPdcpFail ......................................................................... 90
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
vii
Contents
Figure 48. Figure 49. Figure 50. Figure 51. Figure 52. Figure 53. Figure 54. Figure 55. Figure 56. Figure 57. Figure 58. Figure 59. Figure 60. Figure 61. Figure 62. Figure 63. Figure 64. Figure 65. Figure 66. Figure 67. Figure 68. Figure 69. Figure 70. Figure 71. Figure 72. Figure 73. Figure 74. Figure 75. Figure 76. Figure 77. Figure 78. Figure 79. Figure 80. Figure 81. Figure 82. Figure 83. Figure 84. Figure 85. Figure 86. Figure 87. Figure 88. Figure 89. Figure 90. Figure 91. Figure 92. Figure 93. Figure 94. Figure 95. Figure 96. Figure 97. Figure 98. Figure 99.
Collection Time for ConnReEstabFail_UpRlcFail (1) ....................................................................... 91 Collection Time for ConnReEstabFail_UpRlcFail (2) ....................................................................... 91 Collection Time for ConnReEstabFail_RrcSigTo (1) ........................................................................ 92 Collection Time for ConnReEstabFail_RrcSigTo (2) ........................................................................ 93 Collection Time for ConnReEstabFail_S1apLinkFail (1) .................................................................. 93 Collection Time for ConnReEstabFail_S1apLinkFail (2) .................................................................. 94 Collection Time for ConnReEstabFail_S1apLSigFail (1) .................................................................. 94 Collection Time for ConnReEstabFail_S1apLSigFail (2) .................................................................. 95 Collection Time for ConnReEstabReject_CpCcFail (1) .................................................................... 95 Collection Time for ConnReEstabReject_CpCcFail (2) .................................................................... 96 Collection Time for ConnReEstabReject_CpCcFail (3) .................................................................... 96 Collection Time for ConnReEstabReject_CpCcFail (4) .................................................................... 97 Collection Time for ConnReEstabReject_CpCcFail (5) .................................................................... 97 Collection Time for ConnReEstabReject_CpCcFail (6) .................................................................... 98 Collection Time for ConnReEstabReject_CpCapaCacFail ............................................................... 98 Collection Time for ConnReEstabReject_CpQosCacFail ................................................................. 99 Collection Time for ConnRelease_CpCcNormal ........................................................................... 112 Collection Time for ConnRelease_CpCcTo ................................................................................... 112 Collection Time for ConnRelease_CpCcFail (1) ............................................................................ 113 Collection Time for ConnRelease_CpCcFail (2) ............................................................................ 113 Collection Time for ConnRelease_CpCcFail (3) ............................................................................ 113 Collection Time for ConnRelease_CpCcFail (4) ............................................................................ 114 Collection Time for ConnRelease_UpGtpFail ............................................................................... 114 Collection Time for ConnRelease_UpMacFail (1) ......................................................................... 114 Collection Time for ConnRelease_UpMacFail (2) ......................................................................... 115 Collection Time for ConnRelease_UpMacUEInact ....................................................................... 115 Collection Time for ConnRelease_UpPdcpFail ............................................................................. 116 Collection Time for ConnRelease_UpRlcFail (1) ........................................................................... 116 Collection Time for ConnRelease_UpRlcFail (2) ........................................................................... 117 Collection Time for ConnRelease_RrcHcTo .................................................................................. 118 Collection Time for ConnRelease_RrcSigFail (1)........................................................................... 118 Collection Time for ConnRelease_RrcSigFail (2)........................................................................... 119 Collection Time for ConnRelease_RrcSigFail (3)........................................................................... 119 Collection Time for ConnRelease_RrcSigTo ................................................................................. 120 Collection Time for ConnRelease_CpBhCacFail............................................................................ 121 Collection Time for ConnRelease_CpCapaCacFail ........................................................................ 121 Collection Time for ConnRelease_CpQosCacFail ......................................................................... 122 Collection Time for ConnRelease_S1apCuFail .............................................................................. 122 Collection Time for ConnRelease_S1apLinkFail (1) ...................................................................... 123 Collection Time for ConnRelease_S1apLinkFail (2) ...................................................................... 123 Collection Time for ConnRelease_S1apRoTo (1) .......................................................................... 124 Collection Time for ConnRelease_S1apRoTo (2) .......................................................................... 125 Collection Time for ConnRelease_S1apRoTo (3) .......................................................................... 126 Collection Time for ConnRelease_S1apSigFail (1) ........................................................................ 127 Collection Time for ConnRelease_S1apSigFail (2) ........................................................................ 127 Collection Time for ConnRelease_S1apSigFail (3) ........................................................................ 128 Collection Time for ConnRelease_S1apSigTo ............................................................................... 129 Collection Time for ConnRelease_X2apCuFail ............................................................................. 129 Collection Time for ConnRelease_X2apRoTo ............................................................................... 130 Collection Time for ConnRelease_X2apSigFail (1) ........................................................................ 131 Collection Time for ConnRelease_X2apSigFail (2) ........................................................................ 132 Collection Time for RRC Connection Number .............................................................................. 135
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
viii
Contents
Figure 100. Figure 101. Figure 102. Figure 103. Figure 104. Figure 105. Figure 106. Figure 107. Figure 108. Figure 109. Figure 110. Figure 111. Figure 112. Figure 113. Figure 114. Figure 115. Figure 116. Figure 117. Figure 118. Figure 119. Figure 120. Figure 121. Figure 122. Figure 123. Figure 124. Figure 125. Figure 126. Figure 127. Figure 128. Figure 129. Figure 130. Figure 131. Figure 132. Figure 133. Figure 134. Figure 135. Figure 136. Figure 137. Figure 138. Figure 139. Figure 140. Figure 141. Figure 142. Figure 143. Figure 144. Figure 145. Figure 146. Figure 147. Figure 148. Figure 149. Figure 150. Figure 151.
Collection Time for Release Call Holding Time ............................................................................. 136 Collection Time for RRC Connection Number per PLMN ............................................................. 138 Collection Time for RRC Connection Setup Time ......................................................................... 141 Collection Time for Re-establishment Time ................................................................................. 144 Collection Time for CallDrop_EccbDspAuditRlcMacCallRelease .................................................. 150 Collection Time for CallDrop_EccbRcvResetRequestFromEcmb .................................................. 150 Collection Time for CallDrop_EccbRcvCellReleaseIndFromEcmb ................................................ 151 Collection Time for CallDrop_EccbRadioLinkFailure .................................................................... 151 Collection Time for CallDrop_EccbDspAuditMacCallRelease ....................................................... 152 Collection Time for CallDrop_EccbArqMaxReTransmission ......................................................... 152 Collection Time for CallDrop_EccbDspAuditRlcCallRelease ......................................................... 153 Collection Time for CallDrop_EccbTmoutRrcConnectionReconfig............................................... 153 Collection Time for CallDrop_EccbTmoutRrcConnectionReestablish .......................................... 154 Collection Time for CallDrop_EccbS1SctpOutOfService (1) ......................................................... 155 Collection Time for CallDrop_EccbS1SctpOutOfService (2) ......................................................... 155 Collection Time for CallDropQci_EccbDspAuditRlcMacCallRelease ............................................. 161 Collection Time for CallDropQci_EccbRcvResetRequestFromEcmb ............................................ 162 Collection Time for CallDropQci_EccbRcvCellReleaseIndFromEcmb ........................................... 162 Collection Time for CallDropQci_EccbRadioLinkFailure ............................................................... 163 Collection Time for CallDropQci_EccbDspAuditMacCallRelease ................................................. 164 Collection Time for CallDropQci_EccbArqMaxReTransmission ................................................... 165 Collection Time for CallDropQci_EccbDspAuditRlcCallRelease .................................................... 166 Collection Time for CallDropQci_EccbTmoutRrcConnectionReconfig ......................................... 166 Collection Time for CallDropQci_EccbTmoutRrcConnectionReestablish ..................................... 167 Collection Time for CallDropQci_EccbS1SctpOutOfService (1) .................................................... 168 Collection Time for CallDropQci_EccbS1SctpOutOfService (2) .................................................... 168 Collection Time for ErabIncomingHoSuccNbr (1) ......................................................................... 169 Collection Time for ErabIncomingHoSuccNbr (2) ......................................................................... 170 Collection Time for E-RAB Setup .................................................................................................. 205 Collection Time for ErabInitFailNbr_CpCcTo ................................................................................ 206 Collection Time for ErabInitFailNbr_CpCcFail .............................................................................. 206 Collection Time for ErabInitFailNbr_UpGtpFail ............................................................................ 207 Collection Time for ErabInitFailNbr_UpMacFail ........................................................................... 207 Collection Time for ErabInitFailNbr_UpPdcpFail .......................................................................... 208 Collection Time for ErabInitFailNbr_UpRlcFail ............................................................................. 209 Collection Time for ErabInitFailNbr_RrcSigFail ............................................................................ 210 Collection Time for ErabInitFailNbr_RrcSigTo .............................................................................. 211 Collection Time for ErabInitFailNbr_CpBhCacFail ........................................................................ 212 Collection Time for ErabInitFailNbr_CpCapaCacFail .................................................................... 212 Collection Time for ErabInitFailNbr_CpQosCacFail ...................................................................... 213 Collection Time for ErabInitFailNbr_S1apCuFail .......................................................................... 213 Collection Time for ErabInitFailNbr_S1apLinkFail ........................................................................ 214 Collection Time for ErabInitFailNbr_S1apSigFail .......................................................................... 214 Collection Time for ErabAddFailNbr_CpCcTo ............................................................................... 222 Collection Time for ErabAddFailNbr_CpCcFail ............................................................................. 222 Collection Time for ErabAddFailNbr_UpGtpFail ........................................................................... 223 Collection Time for ErabAddFailNbr_UpMacFail .......................................................................... 223 Collection Time for ErabAddFailNbr_UpPdcpFail ......................................................................... 224 Collection Time for ErabAddFailNbr_UpRlcFail ............................................................................ 225 Collection Time for ErabAddFailNbr_RrcSigFail ........................................................................... 226 Collection Time for ErabAddFailNbr_RrcSigTo ............................................................................. 226 Collection Time for ErabAddFailNbr_CpBhCacFail ....................................................................... 227
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
ix
Contents
Figure 152. Figure 153. Figure 154. Figure 155. Figure 156. Figure 157. Figure 158. Figure 159. Figure 160. Figure 161. Figure 162. Figure 163. Figure 164. Figure 165. Figure 166. Figure 167. Figure 168. Figure 169. Figure 170. Figure 171. Figure 172. Figure 173. Figure 174. Figure 175. Figure 176. Figure 177. Figure 178. Figure 179. Figure 180. Figure 181. Figure 182. Figure 183. Figure 184. Figure 185. Figure 186. Figure 187. Figure 188. Figure 189. Figure 190. Figure 191. Figure 192. Figure 193. Figure 194. Figure 195. Figure 196. Figure 197. Figure 198. Figure 199. Figure 200. Figure 201. Figure 202. Figure 203.
Collection Time for ErabAddFailNbr_CpCapaCacFail ................................................................... 227 Collection Time for ErabAddFailNbr_CpQosCacFail ..................................................................... 228 Collection Time for ErabAddFailNbr_S1apCuFail ......................................................................... 228 Collection Time for ErabAddFailNbr_S1apLinkFail ....................................................................... 228 Collection Time for ErabAddFailNbr_S1apSigFail ......................................................................... 229 Collection Time for ErabAddFailNbr_CpCcInteraction ................................................................. 230 Collection Time for E-RAB Setup time .......................................................................................... 232 Collection Time for E-RAB Erase Request ..................................................................................... 238 Collection Time for EraseAttbyEnb_CpCcTo ................................................................................ 239 Collection Time for EraseAttbyEnb_CpCcFail ............................................................................... 239 Collection Time for EraseAttbyEnb_UpGtpFail ............................................................................ 240 Collection Time for EraseAttbyEnb_UpMacFail ........................................................................... 240 Collection Time for EraseAttbyEnb_UpMacUEInact .................................................................... 241 Collection Time for EraseAttbyEnb_UpPdcpFail .......................................................................... 241 Collection Time for EraseAttbyEnb_UpRlcFail ............................................................................. 242 Collection Time for EraseAttbyEnb_RrcHcTo ............................................................................... 243 Collection Time for EraseAttbyEnb_RrcSigFail ............................................................................. 244 Collection Time for EraseAttbyEnb_RrcSigTo............................................................................... 244 Collection Time for EraseAttbyEnb_S1apCuFail ........................................................................... 245 Collection Time for EraseAttbyEnb_S1apRoTo ............................................................................ 245 Collection Time for EraseAttbyEnb_S1apSigTo ............................................................................ 246 Collection Time for EraseAttbyEnb_X2apRoTo ............................................................................ 247 Collection Time for E-RAB erase................................................................................................... 249 Collection Time for E-RAB modify ................................................................................................ 257 Collection Time for ModQoSFailNbr_CpCcTo .............................................................................. 258 Collection Time for ModQoSFailNbr_CpCcFail ............................................................................. 258 Collection Time for ModQoSFailNbr_UpGtpFail .......................................................................... 259 Collection Time for ModQoSFailNbr_UpMacFail ......................................................................... 259 Collection Time for ModQoSFailNbr_UpPdcpFail ........................................................................ 259 Collection Time for ModQoSFailNbr_UpRlcFail ........................................................................... 260 Collection Time for ModQoSFailNbr_RrcSigFail ........................................................................... 261 Collection Time for ModQoSFailNbr_RrcSigTo ............................................................................ 261 Collection Time for ModQoSFailNbr_CpBhCacFail ....................................................................... 262 Collection Time for ModQoSFailNbr_CpCapaCacFail ................................................................... 262 Collection Time for ModQoSFailNbr_CpQosCacFail ..................................................................... 262 Collection Time for ModQoSFailNbr_S1apCuFail ......................................................................... 263 Collection Time for ModQoSFailNbr_S1apLinkFail ...................................................................... 263 Collection Time for ModQoSFailNbr_S1apSigFail ........................................................................ 263 Collection Time for ModQoSFailNbr_CpCcInteraction ................................................................. 264 Collection Time for eNB E-RAB release request ........................................................................... 266 Collection Time for RelAttbyEnbNbr_CpCcTo .............................................................................. 267 Collection Time for RelAttbyEnbNbr_S1apCuFail ........................................................................ 267 Collection Time for E-RAB release ................................................................................................ 271 Collection Time for RelFailNbr_CpCcFail ...................................................................................... 272 Collection Time for RelFailNbr_S1apSigFail ................................................................................. 272 Collection Time for RelFailNbr_S1apCuFail .................................................................................. 273 Collection Time for RelActive ....................................................................................................... 273 Collection Time for RelFailNbr_CpCcInteraction .......................................................................... 274 Collection Time for RelActive_EccbRadioLinkFailure ................................................................... 275 Collection Time for RelActive_EccbArqMaxReTransmission ........................................................ 276 Collection Time for RelActive_EccbTmoutRrcConnectionReconfig ............................................. 277 Collection Time for RelActive_EccbTmoutRrcConnectionReestablish ......................................... 278
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
x
Contents
Figure 204. Figure 205. Figure 206. Figure 207. Figure 208. Figure 209. Figure 210. Figure 211. Figure 212. Figure 213. Figure 214. Figure 215. Figure 216. Figure 217. Figure 218. Figure 219. Figure 220. Figure 221. Figure 222. Figure 223. Figure 224. Figure 225. Figure 226. Figure 227. Figure 228. Figure 229. Figure 230. Figure 231. Figure 232. Figure 233. Figure 234. Figure 235. Figure 236. Figure 237. Figure 238. Figure 239. Figure 240. Figure 241. Figure 242. Figure 243. Figure 244. Figure 245. Figure 246. Figure 247. Figure 248. Figure 249. Figure 250. Figure 251. Figure 252. Figure 253. Figure 254. Figure 255.
Collection Time for SessionTimeUEAvg/Tot/Cnt .......................................................................... 280 Collection Time for SessionTimeQciAvg/Tot/Cnt ......................................................................... 282 Collection Time for UsageNbrAvgAvg/Max/Tot/Cnt .................................................................... 284 Collection Time for UsageNbrPLMN0~5Avg/Max/Tot/Cnt .......................................................... 290 Collection Time for PLMN0~5QCIReject ...................................................................................... 292 Intra-eNB HandoverStatistics processing ..................................................................................... 293 X2 Based Handover Statistics processing ..................................................................................... 295 S1 Handover Procedure ............................................................................................................... 298 Collection Time for Intra eNB Handover ...................................................................................... 312 Collection Time for IntraEnbPrepFail_CpCcTo ............................................................................. 313 Collection Time for IntraEnbPrepFail_CpCcFail (1) ...................................................................... 314 Collection Time for IntraEnbPrepFail_CpCcFail (2) ...................................................................... 315 Collection Time for IntraEnbPrepFail_CpCcFail (3) ...................................................................... 316 Collection Time for IntraEnbPrepFail_CpCcFail (4) ...................................................................... 317 Collection Time for IntraEnbPrepFail_UpMacFail (1) ................................................................... 318 Collection Time for IntraEnbPrepFail_UpMacFail (2) ................................................................... 319 Collection Time for IntraEnbPrepFail_UpRlcFail (1) ..................................................................... 320 Collection Time for IntraEnbPrepFail_UpRlcFail (2) ..................................................................... 321 Collection Time for IntraEnbPrepFail_CpBhCacFail ..................................................................... 322 Collection Time for IntraEnbPrepFail_CpCapaCacFail .................................................................. 323 Collection Time for IntraEnbPrepFail_CpQosCacFail ................................................................... 324 Collection Time for IntraEnbPrepFail_S1apCuFail ........................................................................ 325 Collection Time for IntraEnbPrepFail_S1apLinkFail (1) ................................................................ 326 Collection Time for IntraEnbPrepFail_S1apLinkFail (2) ................................................................ 327 Collection Time for IntraEnbPrepFail_S1apSigFail (1) .................................................................. 328 Collection Time for IntraEnbPrepFail_S1apSigFail (2) .................................................................. 329 Collection Time for IntraEnbFail_CpCcTo ..................................................................................... 330 Collection Time for IntraEnbFail_CpCcFail (1) .............................................................................. 331 Collection Time for IntraEnbFail_CpCcFail (2) .............................................................................. 332 Collection Time for IntraEnbFail_CpCcFail (3) .............................................................................. 333 Collection Time for IntraEnbFail_UpMacFail................................................................................ 334 Collection Time for IntraEnbFail_UpRlcFail (1) ............................................................................ 335 Collection Time for IntraEnbFail_UpRlcFail (2) ............................................................................ 336 Collection Time for IntraEnbFail_RrcHcTo (1) .............................................................................. 337 Collection Time for IntraEnbFail_RrcHcTo (2) .............................................................................. 338 Collection Time for IntraEnbFail_S1apCuFail ............................................................................... 339 Collection Time for IntraEnbFail_S1apLinkFail (1)........................................................................ 340 Collection Time for IntraEnbFail_S1apLinkFail (2)........................................................................ 341 Collection Time for IntraEnbFail_S1apSigFail (1) ......................................................................... 342 Collection Time for IntraEnbFail_S1apSigFail (2) ......................................................................... 343 Collection Time for X2 Handover Out .......................................................................................... 356 Collection Time for InterX2OutPrepFail_CpCcFail........................................................................ 358 Collection Time for InterX2OutPrepFail_S1apLinkFail ................................................................. 359 Collection Time for InterX2OutPrepFail_S1apSigFail ................................................................... 360 Collection Time for InterX2OutPrepFail_X2apCuFail ................................................................... 361 Collection Time for InterX2OutPrepFail_X2apRpTo ..................................................................... 362 Collection Time for InterX2OutFail_CpCcTo ................................................................................. 363 Collection Time for InterX2OutFail_CpCcFail ............................................................................... 364 Collection Time for InterX2OutFail_UpGtpFail ............................................................................ 365 Collection Time for InterX2OutFail_UpPdcpFail........................................................................... 366 Collection Time for InterX2OutFail_UpRlcFail .............................................................................. 367 Collection Time for InterX2OutFail_S1apCuFail ........................................................................... 368
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xi
Contents
Figure 256. Figure 257. Figure 258. Figure 259. Figure 260. Figure 261. Figure 262. Figure 263. Figure 264. Figure 265. Figure 266. Figure 267. Figure 268. Figure 269. Figure 270. Figure 271. Figure 272. Figure 273. Figure 274. Figure 275. Figure 276. Figure 277. Figure 278. Figure 279. Figure 280. Figure 281. Figure 282. Figure 283. Figure 284. Figure 285. Figure 286. Figure 287. Figure 288. Figure 289. Figure 290. Figure 291. Figure 292. Figure 293. Figure 294. Figure 295. Figure 296. Figure 297. Figure 298. Figure 299. Figure 300. Figure 301. Figure 302. Figure 303. Figure 304. Figure 305. Figure 306. Figure 307.
Collection Time for InterX2OutFail_S1apLinkFail ......................................................................... 369 Collection Time for InterX2OutFail_S1apSigFail ........................................................................... 370 Collection Time for InterX2OutFail_X2apRoTo ............................................................................ 371 Collection Time for X2 In Handover ............................................................................................. 382 Collection Time for InterX2InPrepFail_CpCcTo ............................................................................ 384 Collection Time for InterX2InPrepFail_CpCcFail........................................................................... 385 Collection Time for InterX2InPrepFail_UpGtpFail ........................................................................ 386 Collection Time for InterX2InPrepFail_UpMacFail ....................................................................... 387 Collection Time for InterX2InPrepFail_UpPdcpFail ...................................................................... 388 Collection Time for InterX2InPrepFail_UpRlcFail ......................................................................... 389 Collection Time for InterX2InPrepFail_CpBhCacFail .................................................................... 390 Collection Time for InterX2InPrepFail_CpCapaCacFail ................................................................. 391 Collection Time for InterX2InPrepFail_CpQosCacFail .................................................................. 392 Collection Time for InterX2InPrepFail_S1apLinkFail .................................................................... 393 Collection Time for InterX2InPrepFail_S1apSigFail ...................................................................... 394 Collection Time for InterX2InPrepFail_X2apCuFail ...................................................................... 395 Collection Time for InterX2InPrepFail_X2apSigFail ...................................................................... 396 Collection Time for InterX2InFail_CpCcTo (1) .............................................................................. 397 Collection Time for InterX2InFail_CpCcTo (2) .............................................................................. 398 Collection Time for InterX2InFail_CpCcFail .................................................................................. 400 Collection Time for InterX2InFail_UpGtpFail ............................................................................... 401 Collection Time for InterX2InFail_UpPdcpFail ............................................................................. 402 Collection Time for InterX2InFail_RrcHcTo .................................................................................. 403 Collection Time for InterX2InFail_S1apLinkFail ............................................................................ 404 Collection Time for InterX2InFail_S1apCuFail .............................................................................. 405 Collection Time for InterX2InFail_S1apPathTo ............................................................................ 406 Collection Time for InterX2InFail_S1apSigFail .............................................................................. 408 Collection Time for InterX2InFail_X2apSigFail ............................................................................. 409 Collection Time for InterX2InFail_X2apSigTo ............................................................................... 410 Collection Time for S1 Handover Out........................................................................................... 422 Collection Time for InterS1OutPrepFail_CpCcFail(1) ................................................................... 424 Collection Time for InterS1OutPrepFail_CpCcFail(2) ................................................................... 425 Collection Time for InterS1OutPrepFail_CpCcFail(3) ................................................................... 426 Collection Time for InterS1OutPrepFail_S1apCuFail .................................................................... 427 Collection Time for InterS1OutPrepFail_S1apLinkFail ................................................................. 428 Collection Time for InterS1OutPrepFail_S1apLinkFail ................................................................. 429 Collection Time for InterS1OutPrepFail_S1apRpTo ..................................................................... 430 Collection Time for InterS1OutPrepFail_S1apSigFail (1) .............................................................. 431 Collection Time for InterS1OutPrepFail_S1apSigFail (2) .............................................................. 432 Collection Time for InterS1OutFail_CpCcTo (1) ........................................................................... 433 Collection Time for InterS1OutFail_CpCcTo (2) ........................................................................... 434 Collection Time for InterS1OutFail_CpCcTo (3) ........................................................................... 435 Collection Time for InterS1OutFail_CpCcFail (1) .......................................................................... 436 Collection Time for InterS1OutFail_CpCcFail (2) .......................................................................... 437 Collection Time for InterS1OutFail_CpCcFail (3) .......................................................................... 438 Collection Time for InterS1OutFail_UpGtpFail ............................................................................. 439 Collection Time for InterS1OutFail_UpPdcpFail ........................................................................... 440 Collection Time for InterS1OutFail_UpRlcFail .............................................................................. 441 Collection Time for InterS1OutFail_S1apCuFail ........................................................................... 442 Collection Time for InterS1OutFail_S1apLinkFail (1) .................................................................... 443 Collection Time for InterS1OutFail_S1apLinkFail (2) .................................................................... 444 Collection Time for InterS1OutFail_S1apRoTo ............................................................................. 445
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xii
Contents
Figure 308. Figure 309. Figure 310. Figure 311. Figure 312. Figure 313. Figure 314. Figure 315. Figure 316. Figure 317. Figure 318. Figure 319. Figure 320. Figure 321. Figure 322. Figure 323. Figure 324. Figure 325. Figure 326. Figure 327. Figure 328. Figure 329. Figure 330. Figure 331. Figure 332. Figure 333. Figure 334. Figure 335. Figure 336. Figure 337. Figure 338. Figure 339. Figure 340. Figure 341. Figure 342. Figure 343. Figure 344. Figure 345. Figure 346. Figure 347. Figure 348. Figure 349. Figure 350. Figure 351. Figure 352. Figure 353. Figure 354. Figure 355. Figure 356. Figure 357. Figure 358. Figure 359.
Collection Time for InterS1OutFail_S1apSigFail (1)...................................................................... 446 Collection Time for InterS1OutFail_S1apSigFail (2)...................................................................... 447 Collection Time for S1 Handover In.............................................................................................. 461 Collection Time for InterS1InPrep_FailCpCcTo ............................................................................ 463 Collection Time for InterS1InPrep_FailCpCcFail (1) ..................................................................... 464 Collection Time for InterS1InPrep_FailCpCcFail (2) ..................................................................... 465 Collection Time for InterS1InPrep_FailCpCcFail (3) ..................................................................... 466 Collection Time for InterS1InPrep_FailCpCcFail (4) ..................................................................... 467 Collection Time for InterS1InPrep_FailUpGtpFail ........................................................................ 468 Collection Time for InterS1InPrep_FailUpMacFail ....................................................................... 469 Collection Time for InterS1InPrep_FailUpPdcpFail ...................................................................... 470 Collection Time for InterS1InPrep_FailUpRlcFail ......................................................................... 471 Collection Time for InterS1InPrep_FailCpBhCacFail ..................................................................... 472 Collection Time for InterS1InPrep_FailCpCapaCacFail ................................................................. 473 Collection Time for InterS1InPrep_FailCpQosCacFail ................................................................... 474 Collection Time for InterS1InPrep_FailS1apCuFail ....................................................................... 475 Collection Time for InterS1InPrep_FailS1apLinkFail(1) ................................................................ 476 Collection Time for InterS1InPrep_FailS1apLinkFail (2) ............................................................... 477 Collection Time for InterS1InPrepFail_S1apSigFail (1) ................................................................. 478 Collection Time for InterS1InPrepFail_S1apSigFail (2) ................................................................. 479 Collection Time for InterS1InFail_CpCcTo .................................................................................... 480 Collection Time for InterS1InFail_CpCcFail (1) ............................................................................. 481 Collection Time for InterS1InFail_CpCcFail (2) ............................................................................. 482 Collection Time for InterS1InFail_CpCcFail (3) ............................................................................. 483 Collection Time for InterS1InFail_UpPdcpFail .............................................................................. 484 Collection Time for InterS1InFail_RrcHcTo .................................................................................. 485 Collection Time for InterS1InFail_S1apCuFail .............................................................................. 486 Collection Time for InterS1InFail_S1apLinkFail (1) ....................................................................... 487 Collection Time for InterS1InFail_S1apLinkFail (2) ....................................................................... 488 Collection Time for InterS1InFail_S1apSigFail (1) ........................................................................ 489 Collection Time for InterS1InFail_S1apSigFail (2) ........................................................................ 490 Collection Time for InterS1InFail_S1apSigTo ............................................................................... 491 Collection Time for Handover Time (Intra) .................................................................................. 495 Collection Time for Handover Time(Inter S1) .............................................................................. 496 Collection Time for Handover Time(Inter X2) .............................................................................. 497 Collection Time for Outgoing Intra-Frequency HO (Intra eNB) .................................................... 513 Collection Time for Outgoing Intra-Frequency HO (X2) ............................................................... 514 Collection Time for Outgoing Intra-Frequency HO (S1) ............................................................... 515 Collection Time for IntraFreqOutPrepFail_CpCcFail (Intra eNB) .................................................. 516 Collection Time for IntraFreqOutPrepFail_CpCcFail (X2) ............................................................. 517 Collection Time for IntraFreqOutPrepFail_CpCcFail (S1) ............................................................. 518 Collection Time for IntraFreqOutPrepFail_S1apCuFail (Intra eNB) .............................................. 519 Collection Time for IntraFreqOutPrepFail_S1apCuFail (X2) ......................................................... 520 Collection Time for IntraFreqOutPrepFail_S1apCuFail (S1) ......................................................... 521 Collection Time for IntraFreqOutPrepFail_S1apLinkFail (Intra eNB)............................................ 522 Collection Time for IntraFreqOutPrepFail_S1apLinkFail (X2) ....................................................... 523 Collection Time for IntraFreqOutPrepFail_S1apLinkFail (S1) ....................................................... 524 Collection Time for IntraFreqOutPrepFail_S1apRpTo .................................................................. 525 Collection Time for IntraFreqOutPrepFail_S1apSigFail (Intra eNB) ............................................. 526 Collection Time for IntraFreqOutPrepFail_S1apSigFail (X2) ......................................................... 527 Collection Time for IntraFreqOutPrepFail_S1apSigFail (S1) ......................................................... 528 Collection Time for IntraFreqOutPrepFail_X2apCuFail ................................................................ 529
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xiii
Contents
Figure 360. Figure 361. Figure 362. Figure 363. Figure 364. Figure 365. Figure 366. Figure 367. Figure 368. Figure 369. Figure 370. Figure 371. Figure 372. Figure 373. Figure 374. Figure 375. Figure 376. Figure 377. Figure 378. Figure 379. Figure 380. Figure 381. Figure 382. Figure 383. Figure 384. Figure 385. Figure 386. Figure 387. Figure 388. Figure 389. Figure 390. Figure 391. Figure 392. Figure 393. Figure 394. Figure 395. Figure 396. Figure 397. Figure 398. Figure 399. Figure 400. Figure 401. Figure 402. Figure 403. Figure 404. Figure 405. Figure 406. Figure 407. Figure 408. Figure 409. Figure 410. Figure 411.
Collection Time for IntraFreqOutPrepFail_X2apRpTo .................................................................. 530 Collection Time for IntraFreqOutFail_CpCcTo (Intra eNB) ........................................................... 531 Collection Time for IntraFreqOutFail_CpCcTo (X2) ...................................................................... 532 Collection Time for IntraFreqOutFail_CpCcTo (S1) ...................................................................... 533 Collection Time for IntraFreqOutFail_CpCcFail (Intra eNB) ......................................................... 534 Collection Time for IntraFreqOutFail_CpCcFail (X2) ..................................................................... 535 Collection Time for IntraFreqOutFail_CpCcFail (S1) ..................................................................... 537 Collection Time for IntraFreqOutFail_UpGtpFail (X2) .................................................................. 538 Collection Time for IntraFreqOutFail_UpGtpFail (S1) .................................................................. 539 Collection Time for IntraFreqOutFail_UpMacFail ........................................................................ 540 Collection Time for IntraFreqOutFail_UpPdcpFail (X2) ................................................................ 541 Collection Time for IntraFreqOutFail_UpPdcpFail (S1) ................................................................ 542 Collection Time for IntraFreqOutFail_UpRlcFail (Intra eNB) ........................................................ 544 Collection Time for IntraFreqOutFail_UpRlcFail (X2) ................................................................... 545 Collection Time for IntraFreqOutFail_UpRlcFail (S1) ................................................................... 546 Collection Time for IntraFreqOutFail_S1apCuFail (Intra eNB) ..................................................... 547 Collection Time for IntraFreqOutFail_S1apCuFail (X2)................................................................. 548 Collection Time for IntraFreqOutFail_S1apCuFail (S1) ................................................................. 549 Collection Time for IntraFreqOutFail_S1apLinkFail (Intra eNB) ................................................... 550 Collection Time for IntraFreqOutFail_S1apLinkFail (X2) .............................................................. 551 Collection Time for IntraFreqOutFail_S1apLinkFail (S1)............................................................... 553 Collection Time for IntraFreqOutFail_S1apROTo ......................................................................... 554 Collection Time for IntraFreqOutFail_S1apSigFail (X2) ................................................................ 555 Collection Time for IntraFreqOutFail_S1apSigFail (S1) ................................................................ 557 Collection Time for IntraFreqOutFail_X2apRoTo ......................................................................... 558 Collection Time for Outgoing Inter-Frequency HO with Measurement Gap (Intra eNB) ............. 574 Collection Time for Outgoing Inter-Frequency HO with Measurement Gap (X2) ........................ 575 Collection Time for Outgoing Inter-Frequency HO with Measurement Gap (S1) ........................ 577 Collection Time for InterFreqMeasGapOutPrepFail_S1apCpCcFail (Intra eNB) ........................... 578 Collection Time for InterFreqMeasGapOutPrepFail_S1apCpCcFail (X2) ...................................... 579 Collection Time for InterFreqMeasGapOutPrepFail_S1apCpCcFail (S1) ...................................... 581 Collection Time for InterFreqMeasGapOutPrepFail_S1apCuFail (Intra eNB) .............................. 582 Collection Time for InterFreqMeasGapOutPrepFail_S1apCuFail (X2) .......................................... 583 Collection Time for InterFreqMeasGapOutPrepFail_S1apCuFail (S1) .......................................... 584 Collection Time for InterFreqMeasGapOutPrepFail_S1apLinkFail (Intra eNB) ............................ 585 Collection Time for InterFreqMeasGapOutPrepFail_S1apLinkFail (X2) ....................................... 586 Collection Time for InterFreqMeasGapOutPrepFail_S1apLinkFail (S1) ........................................ 587 Collection Time for InterFreqMeasGapOutPrepFail_S1apRpTo .................................................. 588 Collection Time for InterFreqMeasGapOutPrepFail_S1apSigFail (Intra eNB) .............................. 589 Collection Time for InterFreqMeasGapOutPrepFail_S1apSigFail (X2) ......................................... 590 Collection Time for InterFreqMeasGapOutPrepFail_S1apSigFail (S1) ......................................... 591 Collection Time for InterFreqMeasGapOutPrepFail_X2apCuFail ................................................. 592 Collection Time for InterFreqMeasGapOutPrepFail_X2apRpTo .................................................. 593 Collection Time for InterFreqMeasGapOutFail_CpCcTo-Intra eNB.............................................. 594 Collection Time for InterFreqMeasGapOutFail_CpCcTo (X2) ....................................................... 595 Collection Time for InterFreqMeasGapOutFail_CpCcTo (S1) ....................................................... 596 Collection Time for InterFreqMeasGapOutFail_CpCcFail (Intra eNB) .......................................... 597 Collection Time for InterFreqMeasGapOutFail_CpCcFail (X2) ..................................................... 598 Collection Time for InterFreqMeasGapOutFail_CpCcFail (S1) ..................................................... 599 Collection Time for InterFreqMeasGapOutFail_UpGtpFail (X2) ................................................... 600 Collection Time for InterFreqMeasGapOutFail_UpGtpFail (S1) ................................................... 601 Collection Time for InterFreqMeasGapOutFail_UpMacFail ......................................................... 603
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xiv
Contents
Figure 412. Figure 413. Figure 414. Figure 415. Figure 416. Figure 417. Figure 418. Figure 419. Figure 420. Figure 421. Figure 422. Figure 423. Figure 424. Figure 425. Figure 426. Figure 427. Figure 428. Figure 429. Figure 430. Figure 431. Figure 432. Figure 433. Figure 434. Figure 435. Figure 436. Figure 437. Figure 438. Figure 439. Figure 440. Figure 441. Figure 442. Figure 443. Figure 444. Figure 445. Figure 446. Figure 447. Figure 448. Figure 449. Figure 450. Figure 451. Figure 452. Figure 453. Figure 454. Figure 455. Figure 456. Figure 457. Figure 458. Figure 459. Figure 460. Figure 461. Figure 462. Figure 463.
Collection Time for InterFreqMeasGapOutFail_UpPdcpFail (X2) ................................................. 604 Collection Time for InterFreqMeasGapOutFail_UpPdcpFail (S1) ................................................. 605 Collection Time for InterFreqMeasGapOutFail_UpRlcFail (Intra eNB)......................................... 607 Collection Time for InterFreqMeasGapOutFail_UpRlcFail (X2) .................................................... 608 Collection Time for InterFreqMeasGapOutFail_UpRlcFail (S1) .................................................... 609 Collection Time for InterFreqMeasGapOutFail_S1apCuFail (Intra eNB) ...................................... 610 Collection Time for InterFreqMeasGapOutFail_S1apCuFail (X2) ................................................. 611 Collection Time for InterFreqMeasGapOutFail_S1apCuFail (S1) ................................................. 612 Collection Time for InterFreqMeasGapOutFail_S1apLinkFail (Intra eNB) .................................... 613 Collection Time for InterFreqMeasGapOutFail_S1apLinkFail (X2) ............................................... 614 Collection Time for InterFreqMeasGapOutFail_S1apLinkFail (S1) ............................................... 615 Collection Time for InterFreqMeasGapOutFail_S1apRoTo .......................................................... 616 Collection Time for InterFreqMeasGapOutFail_S1apSigFail (X2) ................................................. 617 Collection Time for InterFreqMeasGapOutFail_S1apSigFail (S1) ................................................. 618 Collection Time for InterFreqMeasGapOutFail_X2apRoTo .......................................................... 619 Collection Time for Outgoing Inter-Frequency HO without Measurement Gap (Intra eNB) ....... 638 Collection Time for Outgoing Inter-Frequency HO without Measurement Gap (X2) .................. 639 Collection Time for Outgoing Inter-Frequency HO without Measurement Gap (S1) ................... 640 Collection Time for InterFreqNoMeasGapOutPrepFail_CpCcFail (Intra eNB) .............................. 641 Collection Time for InterFreqNoMeasGapOutPrepFail_CpCcFail (X2) ......................................... 642 Collection Time for InterFreqNoMeasGapOutPrepFail_CpCcFail (S1) ......................................... 643 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apCuFail (Intra eNB) .......................... 644 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apCuFail (X2) ..................................... 645 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apCuFail (S1) ..................................... 646 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apLinkFail (Intra eNB) ....................... 647 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apLinkFail (X2) ................................... 648 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apLinkFail (S1) ................................... 649 Collection Time for InterFreqMeasGapOutPrepFail_S1apRpTo .................................................. 650 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apSigFail (Intra eNB) ......................... 651 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apSigFail (X2) ..................................... 652 Collection Time for InterFreqNoMeasGapOutPrepFail_S1apSigFail (S1) ..................................... 653 Collection Time for InterFreqNoMeasGapOutPrepFail_X2apCuFail ............................................ 654 Collection Time for InterFreqNoMeasGapOutPrepFail_X2apRpTo .............................................. 655 Collection Time for InterFreqNoMeasGapOutFail_CpCcTo (Intra Enb) ....................................... 656 Collection Time for InterFreqNoMeasGapOutFail_CpCcTo (X2) .................................................. 657 Collection Time for InterFreqNoMeasGapOutFail_CpCcTo (S1) .................................................. 658 Collection Time for InterFreqNoMeasGapOutFail_CpCcFail (Intra eNB) ..................................... 659 Collection Time for InterFreqNoMeasGapOutFail_CpCcFail (X2)................................................. 660 Collection Time for InterFreqNoMeasGapOutFail_CpCcFail (S1) ................................................. 662 Collection Time for InterFreqNoMeasGapOutFail_UpGtpFail (X2) .............................................. 663 Collection Time for InterFreqNoMeasGapOutFail_UpGtpFail (S1) .............................................. 664 Collection Time for InterFreqNoMeasGapOutFail_UpMacFail .................................................... 666 Collection Time for InterFreqNoMeasGapOutFail_UpPdcpFail (X2) ............................................ 667 Collection Time for InterFreqNoMeasGapOutFail_UpPdcpFail (S1) ............................................ 668 Collection Time for InterFreqNoMeasGapOutFail_UpRlcFail (Intra eNB) .................................... 670 Collection Time for InterFreqNoMeasGapOutFail_UpRlcFail (X2) ............................................... 671 Collection Time for InterFreqNoMeasGapOutFail_UpRlcFail (S1) ............................................... 672 Collection Time for InterFreqNoMeasGapOutFail_S1apCuFail (Intra eNB) ................................. 673 Collection Time for InterFreqNoMeasGapOutFail_S1apCuFail (X2) ............................................ 674 Collection Time for InterFreqNoMeasGapOutFail_S1apCuFail (S1) ............................................. 675 Collection Time for InterFreqNoMeasGapOutFail_S1apLinkFail (Intra eNB) ............................... 676 Collection Time for InterFreqNoMeasGapOutFail_S1apLinkFail (X2) .......................................... 677
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xv
Contents
Figure 464. Figure 465. Figure 466. Figure 467. Figure 468. Figure 469. Figure 470. Figure 471. Figure 472. Figure 473. Figure 474. Figure 475. Figure 476. Figure 477. Figure 478. Figure 479. Figure 480. Figure 481. Figure 482. Figure 483. Figure 484. Figure 485. Figure 486. Figure 487. Figure 488. Figure 489. Figure 490. Figure 491. Figure 492. Figure 493. Figure 494. Figure 495. Figure 496. Figure 497. Figure 498. Figure 499. Figure 500. Figure 501. Figure 502. Figure 503. Figure 504. Figure 505. Figure 506. Figure 507. Figure 508. Figure 509. Figure 510. Figure 511. Figure 512. Figure 513. Figure 514. Figure 515.
Collection Time for InterFreqNoMeasGapOutFail_S1apLinkFail (S1) .......................................... 679 Collection Time for InterFreqNoMeasGapOutFail_S1apRoTo ..................................................... 680 Collection Time for InterFreqNoMeasGapOutFail_S1apSigFail (X2) ............................................ 681 Collection Time for InterFreqNoMeasGapOutFail_S1apSigFail (S1) ............................................ 682 Collection Time for InterFreqNoMeasGapOutFail_X2apRoTo ..................................................... 683 Collection Time for Outgoing Handover with DRX (Intra eNB) .................................................... 697 Collection Time for Outgoing Handover with DRX (X2) ............................................................... 698 Collection Time for Outgoing Handover with DRX (S1) ................................................................ 700 Collection Time for DrxOutPrepFail_CpCcFail (Intra eNB) ........................................................... 701 Collection Time for DrxOutPrepFail_CpCcFail (X2) ...................................................................... 702 Collection Time for DrxOutPrepFail_CpCcFail (S1) ....................................................................... 704 Collection Time for DrxOutPrepFail_S1apCuFail (Intra eNB) ....................................................... 705 Collection Time for DrxOutPrepFail_S1apCuFail (X2) .................................................................. 706 Collection Time for DrxOutPrepFail_S1apCuFail (S1) ................................................................... 707 Collection Time for DrxOutPrepFail_S1apLinkFail (Intra eNB) ..................................................... 708 Collection Time for DrxOutPrepFail_S1apLinkFail (X2) ................................................................ 709 Collection Time for DrxOutPrepFail_S1apLinkFail (S1) ................................................................ 710 Collection Time for DrxOutPrepFail_S1apRpTo ........................................................................... 711 Collection Time for DrxOutPrepFail_S1apSigFail (Intra eNB) ....................................................... 712 Collection Time for DrxOutPrepFail_S1apSigFail (X2) .................................................................. 713 Collection Time for DrxOutPrepFail_S1apSigFail (S1) .................................................................. 714 Collection Time for DrxOutPrepFail_X2apCuFail .......................................................................... 715 Collection Time for DrxOutPrepFail_X2apRpTo ........................................................................... 716 Collection Time for DrxOutFail_CpCcTo (Intra eNB) .................................................................... 717 Collection Time for DrxOutFail_CpCcTo (X2) ............................................................................... 718 Collection Time for DrxOutFail_CpCcTo (S1) ................................................................................ 719 Collection Time for DrxOutFail_CpCcFail (Intra eNB) ................................................................... 720 Collection Time for DrxOutFail_CpCcFail (X2) .............................................................................. 721 Collection Time for DrxOutFail_CpCcFail (S1) .............................................................................. 723 Collection Time for DrxOutFail_UpGtpFail (X2) ........................................................................... 724 Collection Time for DrxOutFail_UpGtpFail (S1) ............................................................................ 725 Collection Time for DrxOutFail_UpMacFail .................................................................................. 726 Collection Time for DrxOutFail_UpPdcpFail (X2) ......................................................................... 727 Collection Time for DrxOutFail_UpPdcpFail (S1) .......................................................................... 728 Collection Time for DrxOutFail_UpRlcFail (Intra eNB) ................................................................. 730 Collection Time for DrxOutFail_UpRlcFail (X2) ............................................................................. 731 Collection Time for DrxOutFail_UpRlcFail (S1) ............................................................................. 732 Collection Time for DrxOutFail_S1apCuFail (Intra eNB) ............................................................... 733 Collection Time for DrxOutFail_S1apCuFail (X2) .......................................................................... 734 Collection Time for DrxOutFail_S1apCuFail (S1) .......................................................................... 735 Collection Time for DrxOutFail_S1apLinkFail (Intra eNB) ............................................................ 736 Collection Time for DrxOutFail_S1apLinkFail (X2) ........................................................................ 737 Collection Time for DrxOutFail_S1apLinkFail (S1) ........................................................................ 739 Collection Time for DrxOutFail_S1apRoTo ................................................................................... 740 Collection Time for DrxOutFail_S1apSigFail (X2).......................................................................... 741 Collection Time for DrxOutFail_S1apSigFail (S1) .......................................................................... 742 Collection Time for DrxOutFail_X2apRoTo................................................................................... 743 Collection Time for Outgoing Handover without DRX (Intra eNB) ............................................... 756 Collection Time for Outgoing Handover without DRX (X2) .......................................................... 757 Collection Time for Outgoing Handover without DRX (S1) .......................................................... 759 Collection Time for NoDrxOutPrepFail_CpCcFail (Intra eNB) ....................................................... 760 Collection Time for NoDrxOutPrepFail_CpCcFail (X2) .................................................................. 761
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xvi
Contents
Figure 516. Figure 517. Figure 518. Figure 519. Figure 520. Figure 521. Figure 522. Figure 523. Figure 524. Figure 525. Figure 526. Figure 527. Figure 528. Figure 529. Figure 530. Figure 531. Figure 532. Figure 533. Figure 534. Figure 535. Figure 536. Figure 537. Figure 538. Figure 539. Figure 540. Figure 541. Figure 542. Figure 543. Figure 544. Figure 545. Figure 546. Figure 547. Figure 548. Figure 549. Figure 550. Figure 551. Figure 552. Figure 553. Figure 554. Figure 555. Figure 556. Figure 557. Figure 558. Figure 559. Figure 560. Figure 561. Figure 562. Figure 563. Figure 564. Figure 565. Figure 566. Figure 567.
Collection Time for NoDrxOutPrepFail_CpCcFail (S1) .................................................................. 762 Collection Time for NoDrxOutPrepFail_S1apCuFail (Intra eNB)................................................... 763 Collection Time for NoDrxOutPrepFail_S1apCuFail (X2) .............................................................. 764 Collection Time for NoDrxOutPrepFail_S1apCuFail (S1) .............................................................. 765 Collection Time for NoDrxOutPrepFail_S1apLinkFail (Intra eNB) ................................................ 766 Collection Time for NoDrxOutPrepFail_S1apLinkFail (X2)............................................................ 767 Collection Time for NoDrxOutPrepFail_S1apLinkFail (S1) ............................................................ 768 Collection Time for NoDrxOutPrepFail_S1apRpTo ....................................................................... 769 Collection Time for NoDrxOutPrepFail_S1apSigFail (Intra eNB) .................................................. 770 Collection Time for NoDrxOutPrepFail_S1apSigFail (X2) ............................................................. 771 Collection Time for NoDrxOutPrepFail_S1apSigFail (S1) .............................................................. 772 Collection Time for NoDrxOutPrepFail_X2apCuFail ..................................................................... 773 Collection Time for NoDrxOutPrepFail_X2apRpTo ...................................................................... 774 Collection Time for NoDrxOutFail_CpCcTo (Intra eNB) ................................................................ 775 Collection Time for NoDrxOutFail_CpCcTo (X2) ........................................................................... 776 Collection Time for NoDrxOutFail_CpCcTo (S1) ........................................................................... 777 Collection Time for NoDrxOutFail_CpCcFail (Intra eNB) .............................................................. 779 Collection Time for NoDrxOutFail_CpCcFail (X2) ......................................................................... 780 Collection Time for NoDrxOutFail_CpCcFail (S1) .......................................................................... 782 Collection Time for NoDrxOutFail_UpGtpFail (X2) ....................................................................... 783 Collection Time for NoDrxOutFail_UpGtpFail (S1) ....................................................................... 784 Collection Time for NoDrxOutFail_UpMacFail ............................................................................. 785 Collection Time for NoDrxOutFail_UpPdcpFail (X2) ..................................................................... 786 Collection Time for NoDrxOutFail_UpPdcpFail (S1) ..................................................................... 787 Collection Time for NoDrxOutFail_UpRlcFail (Intra eNB) ............................................................. 789 Collection Time for NoDrxOutFail_UpRlcFail (X2) ........................................................................ 790 Collection Time for NoDrxOutFail_UpRlcFail (S1) ........................................................................ 791 Collection Time for NoDrxOutFail_S1apCuFail (Intra eNB) .......................................................... 792 Collection Time for NoDrxOutFail_S1apCuFail (X2) ..................................................................... 793 Collection Time for NoDrxOutFail_S1apCuFail (S1)...................................................................... 794 Collection Time for NoDrxOutFail_S1apLinkFail (Intra eNB) ........................................................ 795 Collection Time for NoDrxOutFail_S1apLinkFail (X2) ................................................................... 796 Collection Time for NoDrxOutFail_S1apLinkFail (S1) ................................................................... 798 Collection Time for NoDrxOutFail_S1apRoTo .............................................................................. 799 Collection Time for NoDrxOutFail_S1apSigFail (X2) ..................................................................... 800 Collection Time for NoDrxOutFail_S1apSigFail (S1) ..................................................................... 802 Collection Time for NoDrxOutFail_X2apRoTo .............................................................................. 803 Collection Time for Redirection by CAC ....................................................................................... 805 PS Handover Procedure from E-UTRAN to UTRAN. ..................................................................... 853 Collection Time for Inter-RAT UTRAN PS Handover Out .............................................................. 858 Collection Time for Inter-RAT UTRAN PS Handover Out .............................................................. 859 Collection Time for RatUtranOutPrepFail_S1apCuFail ................................................................. 860 Collection Time for RatUtranOutPrepFail_S1apRpTo .................................................................. 860 Collection Time for Inter-RAT UTRAN PS Handover Out .............................................................. 861 Collection Time for RatUtranOutFail_RrcSigFail .......................................................................... 862 Collection Time for RatUtranOutFail_S1apRoTo .......................................................................... 863 Collection Time for Inter-RAT UTRAN PS Handover In ................................................................. 868 Collection Time for Inter-RAT UTRAN PS Handover In ................................................................. 869 Collection Time for Inter-RAT UTRAN PS Handover In ................................................................. 870 Collection Time for RatInFailUtran_RrcSigFail ............................................................................. 871 Collection Time for UTRAN SRVCC ............................................................................................... 875 Collection Time for UTRAN SRVCC ............................................................................................... 876
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xvii
Contents
Figure 568. Figure 569. Figure 570. Figure 571. Figure 572. Figure 573. Figure 574. Figure 575. Figure 576. Figure 577. Figure 578. Figure 579. Figure 580. Figure 581. Figure 582. Figure 583. Figure 584. Figure 585. Figure 586. Figure 587. Figure 588. Figure 589. Figure 590. Figure 591. Figure 592. Figure 593. Figure 594. Figure 595. Figure 596. Figure 597. Figure 598. Figure 599. Figure 600. Figure 601. Figure 602. Figure 603. Figure 604. Figure 605. Figure 606. Figure 607. Figure 608. Figure 609. Figure 610.
Collection Time for UtranSrvccOutPrepFail_S1apCuFail .............................................................. 877 Collection Time for UtranSrvccOutPrepFail_S1apRpTo ............................................................... 877 Collection Time for UTRAN SRVCC ............................................................................................... 878 Collection Time for UtranSrvccOutFail_RrcSigFail ....................................................................... 879 Collection Time for UtranSrvccOutFail_S1apRoTo ....................................................................... 880 Collection Time for CSFB PS Handover Out .................................................................................. 884 Collection Time for CSFBPsHoUtranPrepFail_S1apCuFail ............................................................ 885 Collection Time for CSFB PS Out Handover .................................................................................. 886 Collection Time for CSFBPsHoUtranPrepFail_S1apRpTo .............................................................. 886 Collection Time for CSFBPsHoUtranFail_S1apRoTo ..................................................................... 887 Collection Time for CSFB PS Out Handover .................................................................................. 888 Collection Time for CSFB Redirection Out .................................................................................... 890 Collection Time for PS Redirection UTRAN Out ........................................................................... 892 Collection Time for GTP Sequence Number per QCI .................................................................... 960 Collection Time for GTP Sequence Number per eNB ................................................................... 963 Collection Time for GTP Forward Traffic ...................................................................................... 981 Collection Time for GTP Forward Traffic ...................................................................................... 982 Collection Time for GTP Forward Traffic ...................................................................................... 983 Collection Time for PdcpSduBitrateDLTot .................................................................................... 986 Collection Time for PdcpSduBitrateULTot .................................................................................... 986 Collection Time for PdcpSduDropRateDL ..................................................................................... 993 Collection Time for PdcpSduLossRateUL ...................................................................................... 996 Collection Time for S1SIG (1)...................................................................................................... 1013 Collection Time for S1SIG (2)...................................................................................................... 1013 Collection Time for S1SIG (3)...................................................................................................... 1014 Collection Time for S1ConnEstabFail_S1apSigTo ....................................................................... 1014 Collection Time for PAGING ....................................................................................................... 1017 Collection Time for Load ............................................................................................................ 1133 Collection Time for Load Histogram ........................................................................................... 1139 Initial attach case ....................................................................................................................... 1185 X2 handover case ....................................................................................................................... 1186 S1 handover case ....................................................................................................................... 1187 Intra eNB handover case ............................................................................................................ 1188 Rrc Reestablishment .................................................................................................................. 1188 Initial attach case ....................................................................................................................... 1191 Intra-eNB handover case............................................................................................................ 1192 X2 handover case ....................................................................................................................... 1193 S1 handover case ....................................................................................................................... 1194 Event A2 case ............................................................................................................................. 1195 Event A4 case ............................................................................................................................. 1195 Event A6 case ............................................................................................................................. 1196 RRC connection re-establishment case ...................................................................................... 1197 RRC connection release case ...................................................................................................... 1198
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xviii
List of Tables Table 1.
Counter Information ........................................................................................................................ 1
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xix
Preface This document provides detailed descriptions for statistical items collected in the Samsung LTE eNB system for data analysis.
Relevance This manual applies to the following products/software. Name
Type
SLR 4.5
Software
Conventions in this Document Samsung Networks product documentation uses the following conventions.
Symbols Symbol
Description Indicates a task. Indicates a shortcut or an alternative method. Provides additional information. Provides information or instructions that you should follow to avoid service failure or damage to equipment. Provides information or instructions that you should follow to avoid personal injury or fatality. Provides antistatic precautions that you should observe.
Menu Commands menu | command This indicates that you must select a command on a menu, where menu is the name of the menu, and command is the name of the command on that menu.
File Names and Paths These are indicated by a bold typeface. For example: Copy filename.ext into the /home/folder1/folder2/bin/ folder.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xx
Preface
User Input and Console Screen Output Text Input and output text is presented in the Courier font. For example, context <designated epc-context-name> CLI commands are presented in bold small caps. For example, Type the RTRV-NE-STS command in the input field.
New and Changed Information This section describes information that has been added/changed since the previous publication of this manual. Item
Description
Changed Family Name
Following family names have been changed. From Ethernet Packet (Outdoor Smallcell) to Ethernet Packet (Pico) From DL ACK-NACK-DTX Ratio to DL-ACK-NACK-DTX Ratio
Changed Index Name
Following index names have been changed. MRO RLF Classification DL Family: Wideband oFrom Neighbor Cell to NeighborCell CQIFamily: DL MCS oFrom Codeword to codeword Family: DL Wideband CQI oFrom Codeword to codeword Family: DL-ACK-NACK-DTX Ratio oFrom Status to status
Revision History The following table lists all versions of this document. Document Number
Product/Software Version
Document Version
Publication Date
Remarks
2600-00G1G3GAT
SLR 3.1
1.0
October 2014
First version
2600-00H4OMGAT
SLR 4.5
1.0
December 2014
-
2600-00H4OMGAT
SLR 4.5
2.0
March 2015
-
2600-00H4OMGAT
SLR 4.5
3.0
May 2015
-
2600-00H4OMGAT
SLR 4.5
4.0
June 2015
-
2600-00H4OMGAT
SLR 4.5
5.0
August 2015
-
2600-00H4OMGAT
SLR 4.5
6.0
December 2015
-
2600-00H4OMGAT
SLR 4.5
7.0
February 2016
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxi
Preface
Organization of This Document Section
Title
Description
Chapter 1
Introduction
This chapter describes the information of counter description fields.
Chapter 2
Counter Descriptions
This chapter describes index, family and type information of counters.
Appendix A
Acronyms
This chapter lists the acronyms used in this document.
Appendix B
Index Range
This chapter explains the index range used for each counter
Related Documentation Samsung eNB Operation Manual for SLR 4.5
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxii
Preface
Personal and Product Safety This product safety information includes European directives, which you must follow. If these do not apply in your country, please follow similar directives that do apply in your country.
CE Marking Samsung networks equipment supplied to certain European countries carries a CE marking. This is the manufacturer's declaration demonstrating that the product complies with the Electromagnetic Compatibility (EMC) Directive (2004/108/EC), the Low Voltage Directive (2006/95/EC), and the Radio and Telecommunications Terminal Equipment (R & TTE) Directive (1999/5/EC).
Electrical The product is designed to operate from a -48 V DC supply and is therefore classified as Safe Extra Low Voltage (SELV) equipment. All structural parts are grounded and all input and outputs have built-in isolation from the network. All input and output ports that connect to external power sources are designed to meet relevant national safety requirements. The product contains hazardous energy levels as defined by EN 60950. Care must be taken when maintaining this equipment as injury to personnel or damage to the equipment could result from mistakes. Maintenance should only be carried out by trained and competent engineers who are familiar with the relevant procedures and instructions.
Lasers The product is fitted with optic modules rated as Class 1 radiation-emitting devices under EN 60825-1. During installation, operation, and maintenance, never look into the end of an optical fiber directly or by reflection either with the naked eye or through an optical instrument. Do not operate equipment with exposed fiber connectors-cover these with fiber cables or blanking caps. Do not remove equipment covers during operation unless requested to do so in the documentation. Carry out normal safety precautions when trimming fibers during installation.
Manual Handling Care should be taken when handling equipment. Give due consideration to the weight of the equipment, the physical capability of the individual(s) handling the equipment, and movements such as twisting, bending and stooping, which could lead to skeletal and muscular injuries.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxiii
Preface
Installation Installation must be carried out by trained and competent engineers only. All relevant safety measures should be taken to ensure equipment is not connected to live power and transmission sources during installation. Equipment must be correctly installed in order to meet the relevant safety standards and approval conditions. Each power feed to the unit requires a separate fused feed from the provided power supply. The cable between the power distribution point and the installed equipment must have a minimum cross-sectional area of 2.5 mm2. Rack-mountable equipment must be placed in a standard 19-inch rack and secured with the appropriate fixings as detailed in the installation manual.
Maintenance Maintenance must only be carried out by a suitably trained and competent technician. All safety instructions must be carefully observed at all times. Equipment covers should not be removed while live power and transmission is connected unless in a controlled environment by trained technicians.
Fire The product is powered from a -48 V DC supply. To protect against fire, the equipment is fused.
Environment The product must be operated in an environment with the specified relative humidity and ambient temperature ranges. Keep all liquids away from the equipment as accidental spillage can cause severe damage.
Cooling The product cools down by its own set of cooling fans housed in a fan module. Each fan module detects a fan that is not operating normally. LEDs on the front panel of the fan tray provide an alarm indication in the event of fan failure. In the event of fan failure, take urgent remedial action to restore full cooling capacity. Take appropriate measures to ensure that fan modules do not start spinning during repair and maintenance procedures.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxiv
Preface
Anti-Static Precautions The circuit boards and other modules in the product are sensitive to and easily damaged by static electricity. If any card or sub-assembly is removed from the unit, the following anti-static precautions must be observed at all times:
Service personnel must wear anti-static wrist straps. Circuit boards and sub-assemblies must be placed on ground conductive mats or in conductive bags.
All tools must be discharged to ground before use. The anti-static wrist strap and cord must be checked at regular intervals for their suitability for use.
Grounding To comply with EN 60950, the equipment must be connected to a safety grounding point via a permanent link. Grounding points are located on the product for this purpose. Always connect the ground cable before fitting other cables. The product must remain grounded continuously unless all connections to the power supply and data network are all removed. If equipment is grounded through a cabinet or rack, make sure it is done so properly according to the installation instructions.
Power Supply Connection The equipment is designed to be powered from a -48 V DC supply. Power connections and installation of associated wiring must be carried out by a suitably qualified technician. Only devices that comply with all relevant national safety requirements should be connected to the unit's power supply inlets. Other usage will invalidate any approval given to this equipment. Connection of this equipment to devices that are not marked with all relevant national safety requirements may produce hazardous conditions on the network. When the power supply is obtained by a rectifier/safety isolation transformer, the supply must meet the requirements of EN 60950 providing double/reinforced insulation between hazardous voltages and SELV/TNV circuits. Any battery must be separated from hazardous voltages by reinforced insulation.
Indirect Connection Before indirectly connecting any equipment to another device through a shared power supply, ALWAYS seek advice from a competent engineer. Devices that are not marked according to the relevant national safety standards may produce hazardous conditions on the network.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxv
Preface
Product Disposal To reduce the environmental impact of products, Samsung has joined WEEE compliance activities. The WEEE symbol on the product indicates that the product is covered by the European Directive 2002/96/CE for the disposal of Waste Electrical and Electronic Equipment (WEEE). This means that the product should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. This will help prevent potential negative consequences for the environment and human health. Please check the terms and conditions of the purchase contract for information about correct disposal.
Battery Disposal The product contains a battery on the processor card. The battery should not be disposed of with other household waste. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. The battery incorporated in this product is not user replaceable. For information on its replacement, please contact your service provider. Do not attempt to remove the battery or dispose it in a fire. Do not disassemble, crush, or puncture the battery. End of life recycling materials information is available from Samsung.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxvi
Preface
Equipment Markings Hereby, Samsung Electronics, declares that this [SMM-BMDA6/SLSBR009C/SLS-BR00YJ/SLS-BD10DR/SLS-BD10PJ] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.’ The official Declaration of Conformity may be consulted at Samsung Electronics Euro QA Lab. Blackbushe Business Park Saxony Way, Yateley, Hampshire GU46 6GG, UK. ‘This equipment may be operated in all EU countries.’
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product (Applicable in countries with separate collection systems.) The marking on the battery, manual or packaging indicates that the battery in this product should not be disposed of with other household waste. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. The battery incorporated in this product is not user replaceable. For information on its replacement, please contact your service provider. Do not attempt to remove the battery or dispose it in a fire. Do not disassemble, crush, or puncture the battery. If you intend to discard the product, the waste collection site will take the appropriate measures for the recycling and treatment of the product, including the battery.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
xxvii
Chapter 1
Introduction
The Samsung eNB Counter Description for SLR 4.5 report statistical performance measurements by data samples and data points over time. For more information on how to configure and view counter reports, please see the Samsung eNB Operation Manual for SLR 4.5.
Counter Information Each counter can be described using the items in Table 1 below. Table 1. Counter Information Counter Field
Description
Family Name/Description
A group of counters with the same type that can be identified by the index. A family has a unique family name. Family Name: Unique name of a family Family Description: Short description of the family
Index Name/Range/Description
A logical or physical location of the unit information for collecting counters. Name: Collection unit for gathering the statistics Range: Range of index Description: Short description of index
Type
Name
The name of a counter
Unit
The collection unit of each counter % (percentage) s (seconds) ms (milliseconds) count Mbyte (megabytes) Mbps (megabits per second)
Description
Describes a counter
Trigger
Describes the particular trigger event, trigger duration, trigger condition for the Counter and describes what kind of EVENT updates the counter.
Visible
Shows whether a type is displayed in the LSM
Counter Type
Shows the operation of each counter type Gauge: Gets the maximum, minimum and average values of the raw data collected during the collection period. CC (Cumulative Counter): Counts the event every time it occurs and calculates the number of events occurred during the collection period. SI (Status Inspection): Measures the data at the specified interval and calculates the mean value of the data measured during the collection period. OW (Overwrite): Overwrites a value every time an event occurs.
Trigger Type
Shows the trigger type, which can be one of the following: Event: Statistics data is collected when a specific event occurs. Time: The time to collect statistics data, for example, 2 s, 10 s, 1.25 ms,
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Chapter 1 Introduction Counter Field
Description and so on. Period: The duration to gather data that is collected within the specified time or data, for example, 15 min, 30 min, 1 hour, and so on.
Data Type
The counter’s data type
Min/Max
Describes min and max value of statistics type.
Granularity Formula
Describes the granularity formula for the statistics type
Hourly, Daily, Monthly Formula
Describes the hourly, daily, monthly formula for the statistics Type
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
2
Chapter 2
Counter Description
The Samsung SLR 4.5 system counters are described in detail in this chapter.
Resource Management This section provides statistics for the resource status of the system.
Resource This section provides statistics on the CPU, memory and disk resources used by internal applications in the system.
CPU usage: Average, maximum and minimum CPU usage in percentage (%). Memory usage: Average, maximum and minimum DRAM usage in percentage (%). Disk usage: Average, maximum and minimum disk usage in percentage (%). Index Name
Description
ShelfId
Shelf ID.
SlotId
The ID of the slot where the board is mounted.
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
MemUsageAvg
%
The average of memory usage rate
This counter collects memory data from OSSM and reports
Y
GAUGE
10 s
float
0~100
MemUsage Tot/MemUs
sum(MemUsage Tot)/sum(MemUs
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
3
Chapter 2 Counter Description Name
Unit
Description
Trigger
that are collected with a period of 10 seconds
them to PM at 10-second intervals.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula ageCnt
Hourly, Daily, Monthly Formula ageCnt)
MemUsageMin
%
The minimum number of MemUsageAvg
This counter is updated when MemUsageAvg is collected and it is smaller than previously saved minimum value
Y
GAUGE
10 s
float
0~100
-
min(MemUsageM in)
MemUsageMax
%
The maximum number of MemUsageAvg
This counter is updated when MemUsageAvg is collected and it is greater than previously saved minimum value
Y
GAUGE
10 s
float
0~100
-
max(MemUsage Max)
MemUsageTot
%
The cumulative number of MemUsageAvg
This counter is cumulated when MemUsgagAvg is collected
-
GAUGE
10 s
float
0~3.4*10 ^38
-
-
MemUsageCnt
count
The collection count of MemUsageAvg
This counter is cumulated by 1 when MemUsageAvg is collected
-
GAUGE
10 s
int
0~21474 83647
-
-
CpuUsageAvg
%
The average of CPU usage rate that are collected with a period of 10 seconds
This counter collects cpu data from OSSM and reports them to PM at 10-second intervals.
Y
GAUGE
10 s
float
0~100
CpuUsage Tot/CpuUs ageCnt
sum(CpuUsageT ot)/sum(CpuUsag eCnt)
CpuUsageMin
%
The minimum number of CpuUsageAvg
This counter is updated when CpuUsageAvg is collected and it is smaller than previously saved minimum value
Y
GAUGE
10 s
float
0~100
-
min(CpuUsageMi n)
CpuUsageMax
%
The maximum number of CpuUsageAvg
This counter is updated when CpuUsageAvg is collected and it is greater than previously saved minimum value
Y
GAUGE
10 s
float
0~100
-
max(CpuUsageM ax)
CpuUsageMax Duration
s
The maximum number of CPU usage time
This counter is updated when CpuUsagMaxDuration is collected and it is greater than
Y
CC
10 s
int
0~60*Pe riod
-
max(CpuUsageM axDuration)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
4
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
previously saved minimum value CpuUsageTot
%
The cumulated number of CpuUsageAvg
This counter is cumulated when CpuUsageAvg is collected
-
GAUGE
10 s
float
0~3.4*10 ^38
-
-
CpuUsageCnt
count
The collection count of CpuUsageAvg
This counter is cumulated by 1 when CpuUsageAvg is collected
-
GAUGE
10 s
int
0~21474 83647
-
-
DiskUsageAvg
%
The average of disk usage rate that are collected with a period of 10 seconds
This counter collects DISK data from OSSM and reports them to PM at 10-second intervals.
Y
GAUGE
10 s
float
0~100
DiskUsage Tot/DiskUs ageCnt
sum(DiskUsageT ot)/sum(DiskUsa geCnt)
DiskUsageMin
%
The maximum number of DiskUsageAvg
This counter is updated when DiskUsageAvg is collected and it is smaller than previously saved minimum value
Y
GAUGE
10 s
float
0~100
-
min(DiskUsageMi n)
DiskUsageMax
%
The maximum number of DiskUsageAvg
This counter is updated when DiskUsageAvg is collected and it is greater than previously saved minimum value
Y
GAUGE
10 s
float
0~100
-
max(DiskUsageM ax)
DiskUsageTot
%
The cumulated number of DiskUsageAvg
This counter is cumulated when DiskUsageAvg is collected
-
GAUGE
10 s
float
0~3.4*10 ^38
-
-
DiskUsageCnt
count
The collection count of DiskUsageAvg
This counter is cumulated by 1 when DiskUsageAvg is collected
-
GAUGE
10 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
5
Chapter 2 Counter Description
Packet Statistics This section provides statistics on Tx/Rx packets that are processed by the system.
Ethernet Packet This section provides details on the number of the Rx/Tx packets or bytes for each port connected to the backhaul. Ethernet interface packet statistics collect the error Ethernet frame count, Tx/Rx link usage, Tx/Rx error rate, and so on. Index Name
Description
PortNum
Port number that can be connected to external devices
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
RxLinkUtilizat ionAvg
%
The average link utilization of packets received outside
This counter is increased when packet are received outside
Y
OW
Period
float
0~10 0
(RxGoodOcte tSumBadOcte tTot*8*100*K _UNIT*K_UNI T+((RxUnicas tPacket+RxBr oadcastPack et+RxMultica stPacket)*20) *8*100)/(10*R xGoodOctetS
(sum(RxGoodOctetSu mBadOctetTot)*8*100 *K_UNIT*K_UNIT+((s um(RxUnicastPacket) +sum(RxBroadcastPa cket)+sum(RxMultica stPacket))*20)*8*100) /(10*sum(RxGoodOct etSumBadOctetCnt)* avg(IfSpeed)*100000 0)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
6
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula umBadOctet Cnt*IfSpeed* 1000000)
Hourly, Daily, Monthly Formula
RxLinkUtilizat ionMax
%
The maximum value of RxLinkUtilizationAvg
This counter is updated when RxLinkUtilizationM ax is collected and it is greater than previously saved minimum value
Y
GAUGE
10 s
float
0~10 0
-
max(RxLinkUtilization Max)
RxErrorRate
%
The ratio of error packets received outside
This counter is increased when Error packet are received
Y
OW
Period
float
0~10 0
(RxFifoOverr un+RxUnders ize+RxFragm ent+RxOversi ze+RxJabber +RxErrorFra me+RxBadCr c+RxCollision +RxLateCollis ion)*100/(Rx UnicastPacke t+RxBroadca stPacket+Rx MulticastPack et+RxFifoOve rrun+RxUnde rsize+RxFrag ment+RxOver size+RxJabb er+RxErrorFr ame+RxBadC rc+RxCollisio n+RxLateColli sion)
(sum(RxFifoOverrun) +sum(RxUndersize)+ sum(RxFragment)+su m(RxOversize)+sum( RxJabber)+sum(RxEr rorFrame)+sum(RxBa dCrc)+sum(RxCollisio n)+sum(RxLateCollisi on))*100/(sum(RxUni castPacket)+sum(Rx BroadcastPacket)+su m(RxMulticastPacket) +sum(RxFifoOverrun) +sum(RxUndersize)+ sum(RxFragment)+su m(RxOversize)+sum( RxJabber)+sum(RxEr rorFrame)+sum(RxBa dCrc)+sum(RxCollisio n)+sum(RxLateCollisi on))
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
7
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
RxGoodOctet
Mbyte s
The cumulated number that indicates the total frame length of normal packets received outside.
This counter is cumulated when normal packets are received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxUnicastPa cket
count
The cumulated number of unicast packets received outside.
This counter is cumulated when unicast packets are received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxBroadcast Packet
count
The cumulated number of broadcast packets received outside.
This counter is cumulated when broadcast packets are received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxMulticastP acket
count
The cumulated number of multicast packets received outside.
This counter is cumulated when multicast packets are received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxFifoOverru n
count
The cumulated number of dropped packets due to insufficient buffer resources among the packets received outside.
This counter is cumulated when a packet among packets received outside is dropped due to insufficient buffer resources.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxUndersize
count
The cumulated number of undersize packets received outside among the error packets.
This counter is cumulated when there is an undersized packet among error packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
8
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
RxFragment
count
The cumulated number of fragment received outside among the error packets.
This counter is cumulated when there is a fragmented packet among error packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxOversize
count
The cumulated number of oversize received outside among the error packets.
This counter is cumulated when there is an oversized packet among error packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxJabber
count
The cumulated number of jabber received outside among the error packets.
This counter is cumulated when there is a Jabber packet among error packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxErrorFram e
count
The cumulated number of error packets received outside.
This counter is cumulated when there is an error packet among packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxBadCrc
count
The cumulated number of CRC error received outside among the error packets.
This counter is cumulated when there is a CRC error packet among error packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxCollision
count
The cumulated number
This counter is
Y
CC
10 s
int
0~21
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
9
Chapter 2 Counter Description Name
Unit
Description
Trigger
of packets that encountered a collision among the packets received outside.
cumulated when a collision occurs among the packets received from the outside.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 4748 3647
Granularity Formula
Hourly, Daily, Monthly Formula
RxLateCollisi on
count
The cumulated number of packets that had a late collision among the packets received outside.
This counter is cumulated when a late collision occurs among the packets received outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
TxLinkUtilizat ionAvg
%
The average link utilization of packets transmitted
This counter is increased when transmitting packets to the outside
Y
OW
Period
float
0~10 0
(TxGoodOcte tSumBadOcte tTot*8*100*K _UNIT*K_UNI T+((TxUnicas tPacket+TxBr oadcastPack et+TxMulticas tPacket)*20)* 8*100)/(10*Tx GoodOctetSu mBadOctetC nt*IfSpeed*10 00000)
(sum(TxGoodOctetSu mBadOctetTot)*8*100 *K_UNIT*K_UNIT+((s um(TxUnicastPacket) +sum(TxBroadcastPa cket)+sum(TxMulticas tPacket))*20)*8*100)/( 10*sum(TxGoodOctet SumBadOctetCnt)*av g(IfSpeed)*1000000)
TxLinkUtilizat ionMax
%
The maximum value of TxLinkUtilizationAvg
This counter is update when TxLinkUtilizationAv g is collected and it is greater than previous maximum value
Y
GAUGE
10 s
float
0~10 0
-
max(TxLinkUtilization Max)
TxErrorRate
%
The ratio of error packets transmitted
This counter is increased when
Y
OW
Period
float
0~10 0
(TxUnderrun BadCrc+TxD
(sum(TxUnderrunBad Crc)+sum(TxDeferred
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
10
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula eferred+TxEC ollisions)*100/ (TxUnicastPa cket+TxBroad castPacket+T xMulticastPac ket+TxUnderr unBadCrc+Tx Deferred+TxE Collisions)
Hourly, Daily, Monthly Formula )+sum(TxECollisions) )*100/(sum(TxUnicast Packet)+sum(TxBroa dcastPacket)+sum(Tx MulticastPacket)+sum (TxUnderrunBadCrc) +sum(TxDeferred)+su m(TxECollisions))
transmitting error packets to the outside
TxGoodOctet
Mbyte s
The cumulated total frame length of packets transmitted outside.
This counter is cumulated when packets are transmitted outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
TxUnicastPa cket
count
The cumulated number of unicast packets transmitted outside.
This counter is cumulated when unicast packets are transmitted outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
TxBroadcast Packet
count
The cumulated number of broadcast packets transmitted outside.
This counter is cumulated when broadcast packets are transmitted outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
TxMulticastP acket
count
The cumulated number of multicast packets transmitted outside.
This counter is cumulated when multicast packets are transmitted outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
TxUnderrunB adCrc
count
The cumulated number of packets that had either under run or
This counter is cumulated when there is a packet
Y
CC
10 s
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
11
Chapter 2 Counter Description Name
Unit
Description
Trigger
CRC error among the packets transmitted outside.
that had either under run or CRC error among packets transmitted outside.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
TxDeferred
count
The cumulated number of delayed transmission packets due to media busy status when ports were open in halfduplex mode among the packets transmitted outside.
This counter is cumulated when there is a delayed packet due to media busy status when ports were open in half-duplex mode among the packets transmitted outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
TxECollisions
count
The cumulated number of cancelled transmission packets due to excessive collision when ports were open in halfduplex mode among the packets transmitted outside.
This counter is cumulated when there is a cancelled packet due to excessive collision when ports were open in half-duplex mode among the packets transmitted outside.
Y
CC
10 s
int
0~21 4748 3647
-
-
RxGoodOctet SumBadOcte tAvg
Mbyte s
The average value of the total frame length of normal and abnormal packets received
This counter is calculated when measurement period comes.
-
GAUGE
10 s
int
0~21 4748 3647
RxGoodOctet SumBadOctet Tot/RxGoodO ctetSumBadO ctetCnt
sum(RxGoodOctetSu mBadOctetTot)/sum( RxGoodOctetSumBa dOctetCnt)
RxGoodOctet SumBadOcte tMax
Mbyte s
The maximum value of RxGoodOctetSumBad OctetAvg
This counter is updated when RxGoodOctetSum
-
GAUGE
10 s
int
0~21 4748 3647
-
max(RxGoodOctetSu mBadOctetMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
12
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
BadOctetAvg is collected and it is greater than previous maximum value RxGoodOctet SumBadOcte tTot
Mbyte s
The cumulated number that indicates the sum of the normal and abnormal packets among those received outside.
This counter is updated when normal packet or Bad packet are received
-
GAUGE
10 s
int
0~21 4748 3647
-
-
RxGoodOctet SumBadOcte tCnt
count
The collection count of RxGoodOctetSumBad OctetAvg
This counter is cumulated by 1 when RxGoodOctetSum BadOctetAvg is collected
-
GAUGE
10 s
int
0~21 4748 3647
-
-
TxGoodOctet SumBadOcte tAvg
Mbyte s
The average number of the total frame length of normal and abnormal packets transmitted
This counter is calculated when measurement period comes.
-
GAUGE
10 s
int
0~21 4748 3647
TxGoodOctet SumBadOctet Tot/TxGoodO ctetSumBadO ctetCnt
sum(TxGoodOctetSu mBadOctetTot)/sum( TxGoodOctetSumBad OctetCnt)
TxGoodOctet SumBadOcte tMax
Mbyte s
The maximum value of TxGoodOctetSumBad OctetAvg
This counter is updated when TxGoodOctetSumB adOctetAvg is collected and it is greater than previously saved maximum value
-
GAUGE
10 s
int
0~21 4748 3647
-
max(TxGoodOctetSu mBadOctetMax)
TxGoodOctet SumBadOcte tTot
Mbyte s
The cumulated number that indicates the sum of the normal and
This counter is update when normal or bad
-
GAUGE
10 s
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
13
Chapter 2 Counter Description Name
Unit
Description
Trigger
abnormal packets among packets transmitted outside.
packet is transmitted.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
TxGoodOctet SumBadOcte tCnt
count
The collection count of TxGoodOctetSumBad OctetAvg
This counter is cumulated by 1 when TxGoodOctetSumB adOctetAvg is collected
-
GAUGE
10 s
int
0~21 4748 3647
-
-
IfSpeed
Mbps
The measured value of the interface speed.
This counter is modified when the interface speed settings are changed.
-
OW
10 s
int
0~21 4748 3647
-
avg(IfSpeed)
RxLinkUtilizat ionMin
%
The minimum value of RxLinkUtilizationAvg
This counter is updated when RxLinkUtilizationAv g is collected and it is smaller than previously saved minimum value
Y
GAUGE
10 s
float
0~10 0
-
min(RxLinkUtilization Min)
TxLinkUtilizat ionMin
%
The minimum value of TxLinkUtilizationAvg
This counter is updated when TxLinkUtilizationAv g is collected and it is smaller than previously saved minimum value
Y
GAUGE
10 s
float
0~10 0
-
min(TxLinkUtilization Min)
RxGoodOctet SumBadOcte tMin
Mbyte s
The minimum value of RxGoodOctetSumBad OctetAvg
This counter is updated when RxGoodOctetSum BadOctetAvg is collected and it is
-
GAUGE
10 s
int
0~21 4748 3647
-
min(RxGoodOctetSu mBadOctetMin)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
14
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
smaller than previously saved minimum value TxGoodOctet SumBadOcte tMin
Mbyte s
The minimum value of TxGoodOctetSumBad OctetAvg
This counter is updated when TxGoodOctetSumB adOctetAvg is collected and it is smaller than previously saved minimum value
-
GAUGE
10 s
int
0~21 4748 3647
-
min(TxGoodOctetSu mBadOctetMin)
RxThruPeak
Mbps
The maximum value of the 1-second peak bandwidth of packets received outside.
This counter is modified when the 1-second bandwidth of packets received outside is greater than the previous value.
Y
OW
10 s
float
0~3. 4*10 ^38
-
max(RxThruPeak)
TxThruPeak
Mbps
The maximum value of the 1-second peak bandwidth of packets transmitted outside.
This counter is modified when the 1-second bandwidth of packets transmitted outside is greater than the previous value.
Y
OW
10 s
float
0~3. 4*10 ^38
-
max(TxThruPeak)
RxThruPeak Cnt
count
The collection count of RxThruPeak
This counter is cumulated when RxThruPeak is collected
-
OW
10 s
Int
0~21 4748 3647
-
-
TxThruPeak Cnt
count
The collection count of TxThruPeak
This counter is cumulated when
-
OW
10 s
int
0~21 4748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
15
Chapter 2 Counter Description Name
Unit
Description
Trigger TxThruPeak is collected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 3647
Granularity Formula
Hourly, Daily, Monthly Formula
16
Chapter 2 Counter Description
Ethernet Packet per VLAN This section provides statistics on the number of Rx/Tx packets or bytes per VLAN, the number of Drop Ethernet packets, and so on. Index Name
Description
VrId
vrId of VRConf PLD
VlanId
dbIndex of VlanConf PLD
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RxThroughput Avg
Mbps
The average incoming throughput per VLAN interface over a periodic time interval
This counter is calculated when measurement period comes.
Y
OW
10 s
float
0~3.4*10 ^38
(RxOctet*8* M_UNIT)/(10 *RxOctetCnt *1000000)
(sum(RxOctet)*8 *M_UNIT)/(10*su m(RxOctetCnt)*1 000000)
RxOctet
Mbytes
The cumulated number of octet unit that corresponds to the length of packets received through VLAN interface.
This counter is cumulated when VLAN packet transmitted from network nodes to the eNB using VLAN is valid.
Y
CC_LL
10 s
int
0~21474 83647
-
-
RxOctetCnt
count
The collection number of RxThroughputAvg
This counter is cumulated when RxThroughputAvg is collected
Y
CC_LL
10 s
int
0~21474 83647
-
-
RxPacket
count
The cumulated number of packets received through VLAN interface.
This counter is cumulated when VLAN packet transmitted from network nodes to the
Y
CC
10 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
17
Chapter 2 Counter Description Name
Unit
Description
RxDropPacket Cnt
count
The cumulated number of packets discarded after being received through VLAN interface.
TxThroughputA vg
Mbps
TxOctet
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when VLAN packet transmitted from network nodes to the eNB using VLAN is invalid.
Y
CC
10 s
int
0~21474 83647
-
-
The average outgoing throughput per VLAN interface over a periodic time interval
This counter is calculated when measurement period comes.
Y
OW
10 s
float
0~3.4*10 ^38
(TxOctet*8* M_UNIT)/(10 *TxOctetCnt *1000000)
(sum(TxOctet)*8* M_UNIT)/(10*su m(TxOctetCnt)*1 000000)
Mbytes
The cumulated number of octet unit that corresponds to the length of packets transmitted through VLAN interface.
This counter is cumulated when VLAN packet transmitted from the eNB to network nodes using VLAN is valid.
Y
CC_LL
10 s
int
0~21474 83647
-
-
TxOctetCnt
count
The collection counter of TxThroughputAvg
This counter is cumulated by 1 when TxThroughputAvg is collected
Y
CC_LL
10 s
int
0~21474 83647
-
-
TxPacket
count
The cumulated number of packets transmitted through VLAN interface.
This counter is cumulated when VLAN packet transmitted from the eNB to network nodes using VLAN is valid.
Y
CC
10 s
int
0~21474 83647
-
-
TxDropPacket Cnt
count
The cumulated number of packets discarded before being transmitted through VLAN interface.
This counter is cumulated when VLAN packet transmitted from the eNB to network nodes using VLAN is
Y
CC
10 s
int
0~21474 83647
-
-
eNB using VLAN is valid.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
18
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
invalid.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
19
Chapter 2 Counter Description
Histogram This section provides statistics on the number of packets per Ethernet packet size received from the External Interface (e.g. backhaul) port. Index Name
Description
PortNum
Port number that can be connected to external devices
Statistics Type Name
Unit
Description
Trigger
Visi ble
Count er Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RxHistogram64
count
The cumulated number when 1~64 byte packets are received outside.
This counter is cumulated when 1~64 byte packets are received outside.
Y
CC
10 s
int
0~2147 483647
-
-
RxHistogram127
count
The cumulated number when 65~127 byte packets are received outside.
This counter is cumulated when 64~127 byte packets are received outside.
Y
CC
10 s
int
0~2147 483647
-
-
RxHistogram255
count
The cumulated number when 128~255 byte packets are received outside.
This counter is cumulated when 128~255 byte packets are received outside.
Y
CC
10 s
int
0~2147 483647
-
-
RxHistogram511
count
The cumulated number when 256~511 byte packets are received outside.
This counter is cumulated when 256~511 byte packets are received outside.
Y
CC
10 s
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
20
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visi ble
Count er Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RxHistogram1023
count
The cumulated number when 512~1023 byte packets are received outside.
This counter is cumulated when 512~1023 byte packets are received outside.
Y
CC
10 s
int
0~2147 483647
-
-
RxHistogramMax
count
The cumulated number when greater than 1024-byte packets are received outside.
This counter is cumulated when the greater than 1024 byte packets are received outside.
Y
CC
10 s
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
21
Chapter 2 Counter Description
Air MAC Packet This section provides statistics on the cell throughput. Air Mac UL/DL bytes (Kbytes) Collects the average size of the transport block (TB) successfully sent/received, among the downlink/uplink TBs that the eNB’s MAC allocated to the UE. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirMacULByte
Kbyt es
The cumulated number that indicates the sum of the size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is cumulated by the number of bytes of the MAC PDU when there is a MAC PDU that has been successfully received through PUSCH.
Y
CC
5.12 s
int
0~21474 83647
-
-
AirMacULByte Cnt
cou nt
The collection count of AirMacByteUl
The counter is cumulated by 1 when the AirMacByteUl is collected.
-
CC_LL
5.12 s
int
0~21474 83647
-
-
AirMacULTti
TTI
The cumulated number of TTIs that have MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is cumulated by 1 when there is a MAC PDU that has been successfully received through PUSCH at each TTI.
Y
CC
5.12 s
int
0~21474 83647
-
-
AirMacULThru
Kbp
The calculated number that
This counter is calculated
Y
OW
Period
float
0~3.4*10
((AirMacUL
((sum(AirMacUL
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
22
Chapter 2 Counter Description Name
Unit
Description
Trigger
Avg
s
indicates the average persecond size of MAC PDUs which were successfully received through PUSCH during the collection interval.
when measurement period comes.
AirMacULEfcti vThruAvg
Kbp s
The overall calculated size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
AirMacDLByte
Kbyt es
The cumulated size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is cumulated by the number of bytes of the MAC PDU when there is a MAC PDU that has successfully transmitted through the PDSCH.
Y
CC
5.12 s
AirMacDLByte Cnt
cou nt
The collection count of AirMacByteDl
The counter is cumulated by 1 when the AirMacByteDl is collected.
-
CC
AirMacDLTti
TTI
The cumulated number of TTIs that have MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is cumulated by 1 when there is a MAC PDU that has successfully transmitted through the PDSCH at each TTI.
Y
AirMacDLThru Avg
Kbp s
The calculated average persecond size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is calculated when measurement period comes.
AirMacDLEfcti vThruAvg
Kbp s
The overall calculated size of MAC PDUs which were successfully transmitted
This counter is calculated when measurement period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula Byte*8)/(51 20*AirMac ULByte Cnt))*K_U NIT
Hourly, Daily, Monthly Formula Byte)*8)/(5120*s um(AirMacULByt eCnt)))*K_UNIT
0~3.4*10 ^38
((AirMacUL Byte*8)/Air MacULTti)* K_UNIT
((sum(AirMacUL Byte)*8)/sum(Air MacULTti))*K_U NIT
int
0~21474 83647
-
-
5.12 s
int
0~21474 83647
-
-
CC
5.12 s
int
0~21474 83647
-
-
Y
OW
Period
float
0~3.4*10 ^38
((AirMacDL Byte*8)/(51 20*AirMac DLByteCnt) )*K_UNIT
((sum(AirMacDL Byte)*8)/(5120*s um(AirMacDLByt eCnt)))*K_UNIT
Y
OW
Period
float
0~3.4*10 ^38
((AirMacDL Byte*8)/Air MacDLTti)*
((sum(AirMacDL Byte)*8)/sum(Air MacDLTti))*K_U
^38
23
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula K_UNIT
Hourly, Daily, Monthly Formula NIT
through PDSCH during the collection interval. AirMacULByte Curr
Kbyt es
The most recent collected AirMacByteUl value
This counter is updated when the AirMacByteUl collected
-
CC
5.12 s
int
0~21474 83647
-
-
AirMacDLByte Curr
Kbyt es
The most recent collected AirMacByteDl value
This counter is updated when the AirMacByteDl collected
-
CC
5.12 s
int
0~21474 83647
-
-
AirMacULThru Min
Kbp s
The minimum value of AirMacByteUl
This counter is updated when the AirMacByteUl is less than previous value
Y
OW
5.12 s
float
0~3.4*10 ^38
-
min(AirMacULTh ruMin)
AirMacULThru Max
Kbp s
The maximum value of AirMacByteUl
This counter is updated when the AirMacByteUl is greater than previous value
Y
OW
5.12 s
float
0~3.4*10 ^38
-
max(AirMacULT hruMax)
AirMacDLThru Min
Kbp s
The minimum value of AirMacByteDl
This counter is updated when the AirMacByteDl is less than previous value
Y
OW
5.12 s
float
0~3.4*10 ^38
-
min(AirMacDLTh ruMin)
AirMacDLThru Max
Kbp s
The maximum value of AirMacByteDl
This counter is updated when the AirMacByteDl is greater than previous value
Y
OW
5.12 s
float
0~3.4*10 ^38
-
max(AirMacDLT hruMax)
ULIpThruVol
Kbyt es
The cumulated number that indicates the sum of the sizes of MAC SDUs that were successfully received through the PUSCH during the sample intervals of all UEs in the collection interval.
This counter is cumulated by the number of bytes of the MAC SDU of the MAC PDU when there is a MAC PDU that has been successfully received through PUSCH for each UE's sample period.
Y
CC
5.12 s
int
-
-
-
ULIpThruTime
TTI
The cumulated number of TTIs during the sample intervals of all UEs in the
This counter is cumulated by 1 at each TTI for each UE's sample period.
Y
CC
5.12 s
int
-
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
24
Chapter 2 Counter Description Name
Unit
ULIpThruAvg
Kbp s
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is calculated when measurement period comes.
Y
OW
Period
float
-
(ULIpThruV ol)*8/(ULIp ThruTime)* K_UNIT
sum(ULIpThruVo l)*8/sum(ULIpThr uTime)*K_UNIT
collection interval. The calculated number that indicates the average persecond size which is derived from that the MAC SDUs that were successfully received through the PUSCH during the sample intervals of all UEs is divided by TTIs during the sample intervals in the collection interval.
Collection Time TTI (Transmission Time Interval: 1 ms)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
25
Chapter 2 Counter Description
Air RLC Packet This section provides statistics on the downlink’s transmitted byte and retransmitted byte count/throughput/IP throughput and the uplink’s transmitted byte count/throughput for the wireless section of the eNB. Since they are collected and summed for each cell and each QCI, they are collected after cell setup has finished. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirRlcULByte
Kbytes
Air RLC uplink bytes Number of bytes transmitted at the RLC as air uplink. Collects the number of data bytes received by the UE for each cell and QCI.
Y
CC
10 s
int
0~2147483647
-
-
AirRlcDLByte
Kbytes
Air RLC downlink bytes Number of bytes transmitted at the RLC as air downlink. Collects the number of data bytes transmitted to the UE for each cell and QCI.
Y
CC
10 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
26
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirRlcDLByteRe
Kbytes
Air RLC downlink ReTx bytes Number of bytes retransmitted at the RLC as air downlink. Collects the number of data bytes transmitted to the UE for each cell and QCI.
Y
CC
10 s
int
0~2147483647
-
-
AirRlcULThru
Kbps
Air uplink throughput Collects the data received from the UE as the air uplink throughput for each cell and QCI.
Y
OW
10 s
float
0~3.4*10^38
(AirRlcULBy te*K_UNIT* 8)/(10*AirRlc ULByteCnt* 1000)
(sum(AirRlcULByte) *K_UNIT*8)/(10*su m(AirRlcULByteCnt )*1000)
AirRlcULThruTot
Kbps
The sum of collected AirRlcULThru
-
OW
10 s
float
0~3.4*10^38
-
-
AirRlcULThruCnt
count
The collection count of AirRlcULThru
-
OW
10 s
int
0~2147483647
-
-
AirRlcDLThru
Kbps
Air downlink throughput Collects the data transmitted to the UE as the air downlink throughput for each cell and QCI.
Y
OW
10 s
float
0~3.4*10^38
(AirRlcDLBy te*K_UNIT* 8)/(10*AirRlc DLByteCnt* 1000)
(sum(AirRlcDLByte) *K_UNIT*8)/(10*su m(AirRlcDLByteCnt )*1000)
AirRlcDLThruTot
Kbps
The sum of collected AirRlcDLThru
-
OW
10 s
float
0~3.4*10^38
-
-
AirRlcDLThruCnt
count
The collection count of AirRlcDLThru
-
OW
10 s
int
0~2147483647
-
-
IpThru
Kbps
IP throughput Collects the IP throughput for each cell and QCI using the method specified in 3GPP TS 32.450.
Y
SI
10 s
float
0~3.4*10^38
(IpThruThpV oDLByte * 8)/(IpThruTh pDLTime / 1000)
(sum(IpThruThpVo DLByte) * 8)/(sum(IpThruThp DLTime) / 1000)
IpThruTot
Kbps
The sum of collected
-
SI
10 s
float
0~3.4*10^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
27
Chapter 2 Counter Description Name
Unit
IpThruCnt
count
AirRlcULByteCurr
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Collection count of IpThru
-
SI
10 s
int
0~2147483647
-
-
Kbytes
The most recently collected AirRlcULByte
-
CC
10 s
int
0~2147483647
-
-
AirRlcDLByteCurr
Kbytes
The most recently collected AirRlcDLByte
-
CC
10 s
int
0~2147483647
-
-
AirRlcULByteCnt
count
The collection count of AirRlcULByte
-
CC
10 s
int
0~2147483647
-
-
AirRlcDLByteCnt
count
The collection count of AirRlcDLByte
-
CC
10 s
int
0~2147483647
-
-
AirRlcULThruMin
Kbps
The Minimum value of AirRlcULByte
Y
OW
10 s
float
0~3.4*10^38
-
min(AirRlcULThruM in)
AirRlcULThruMax
Kbps
The Maximum value of AirRlcULByte
Y
OW
10 s
float
0~3.4*10^38
-
max(AirRlcULThru Max)
AirRlcDLThruMin
Kbps
The Minimum value of AirRlcDLByte
Y
OW
10 s
float
0~3.4*10^38
-
min(AirRlcDLThruM in)
AirRlcDLThruMax
Kbps
The Maximum value of AirRlcDLByte
Y
OW
10 s
float
0~3.4*10^38
-
max(AirRlcDLThru Max)
IpThruMin
Kbps
The minimum value of IpThru
Y
OW
10 s
float
0~3.4*10^38
-
min(IpThruMin)
IpThruMax
Kbps
The maximum value of IpThru
Y
OW
10 s
float
0~3.4*10^38
-
max(IpThruMax)
IpThruThpVoDLByte
Kbps
It is the numerator of IpThru calculation (The sum of data volume which transmits data and removes the last TTI part which a buffer empties)
Y
CC_LL
10 s
Int
0~ 2147483647
-
-
IpThruThpDLTime
ms
It is the denominator of
Y
CC
10 s
int
0~ 2147483647
-
-
IpThru
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
28
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IpThru calculation (The sum of time which transmits data and removes the last TTI part which a buffer empties)
PDCP Packet This section provides statistics on the bytes, packet counts and throughput of user data transmitted and received between the eNB and SGW, which are collected per QCI according to the 3GPP standard (TS32.425 Performance Measurements). Each item is collected by the PDCP layer within the eNB. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EnbQciULBy te
Kbytes
The cumulated DRB packet bytes transmitted from eNB to S-GW
This counter is cumulated when the eNB transmitted the DRB Packet the S-GW
Y
CC
2s
int
0~21474 83647
-
-
EnbQciULTh ru
Kbps
The calculated throughput for EnbQciUL
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10 ^38
(EnbQciUL Byte*K_UNI T*8)/EnbQc iULByteCnt/
(sum(EnbQciULByt e)*K_UNIT*8)/sum (EnbQciULByteCnt )/1000
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
29
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula 1000
Hourly, Daily, Monthly Formula
EnbQciULTh ruMax
Kbps
The maximum value of EnbQciULThru
This counter is updated when EnbQciULThruMax is collected and it is smaller than previous minimum value
Y
GAUGE
2s
float
0~3.4*10 ^38
-
max(EnbQciULThr uMax)
EnbQciULTh ruTot
Kbps
The cumulated number of EnbQciULThru
This counter is cumulated when EnbQciULThru is collected
-
GAUGE
Period
float
0~3.4*10 ^38
-
-
EnbQciULTh ruCnt
count
The collection count of EnbQciULThru
This counter is cumulated when EnbQciULThru is collected
-
GAUGE
Period
int
0~21474 83647
-
-
PacketULCnt
count
The cumulated DRB packets transmitted from eNB to S-GW
This counter is cumulated when the eNB transmitted the DRB Packet the S-GW
Y
CC
2s
int
0~21474 83647
-
-
EnbQciDLBy te
Kbytes
The cumulated bytes of user data which eNB received from SGW
This counter is cumulated when the eNB received the DRB Packet from the S-GW
Y
CC
2s
int
0~21474 83647
-
-
EnbQciDLTh ru
Kbps
The calculated throughput for EnbQciUL
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10 ^38
(EnbQciDL Byte*K_UNI T*8)/EnbQc iDLByteCnt/ 1000
(sum(EnbQciDLByt e)*K_UNIT*8)/sum (EnbQciDLByteCnt )/1000
EnbQciDLTh ruMax
Kbps
The maximum value of EnbQciDLThru
This counter is updated when EnbQciDLThru is collected and it is greater than previous
Y
GAUGE
2s
float
0~3.4*10 ^38
-
max(EnbQciDLThr uMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
30
Chapter 2 Counter Description Name
Unit
Description
EnbQciDLTh ruTot
Kbps
The cumulated number of EnbQciDLThru
EnbQciDLTh ruCnt
count
PacketDLCnt
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when EnbQciDLThru is collected
-
GAUGE
Period
float
0~3.4*10 ^38
-
-
The collection count of EnbQciDLThru
This counter is cumulated when EnbQciDLThru is collected
-
GAUGE
Period
int
0~21474 83647
-
-
count
The cumulated number of packets eNB received from SGW
This counter is cumulated when the eNB received the DRB Packet from the S-GW
Y
CC
2s
int
0~21474 83647
-
-
EnbQciULBy teCnt
s
The cumulated time to collect EnbQciULByte
This counter is calculated when measurement period comes.
Y
OW
Period
int
0~60*Per iod
-
-
EnbQciDLBy teCnt
s
The cumulated time to collect EnbQciDLByte
This counter is calculated when measurement period comes.
Y
OW
Period
int
0~60*Per iod
-
-
EnbQciULTh ruMin
Kbps
The minimum number of EnbQciULThru
This counter is updated when EnbQciULThru is collected and it is smaller than previous minimum value
Y
GAUGE
2s
float
0~3.4*10 ^38
-
min(EnbQciULThru Min)
EnbQciDLTh ruMin
Kbps
The minimum number of EnbQciDLThru
This counter is updated when EnbQciDLThru is collected and it is smaller than previous minimum value
Y
GAUGE
2s
float
0~3.4*10 ^38
-
min(EnbQciDLThru Min)
minimum value
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
31
Chapter 2 Counter Description
Collection Time Figure 1. Collection Time for PacketULByte UE
eNB
MME
S/GW
RRC_CONNECTED Uplink DRB Packet Send - PacketULByte - PacketULCnt
Uplink DRB Packet Receive
Figure 2. Collection Time for EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED Downlink DRB Packet Send - EnbQciDLByte - EnbQciDLCnt
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink DRB Packet Receive
32
Chapter 2 Counter Description
PDCP Packet per PLMN This section provides statistics on the PDCP packets transmitted/received to the serving GW per PLMN. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PLMN0EnbQc iULByte
Kbyte s
The cumulated DRB packet bytes of PLMN (0) that eNB transmitted to S-GW
This counter is cumulated when the eNB transmitted User data of PLMN (0) to the S-GW
Y
CC
2s
int
0~21474 83647
-
-
PLMN0EnbQc iDLByte
Kbyte s
The cumulated DRB packet bytes of PLMN (0) that eNB received from S-GW
This counter is cumulated when the eNB received User data of PLMN (0) from the S-GW
Y
CC
2s
int
0~21474 83647
-
-
PLMN1EnbQc iULByte
Kbyte s
The cumulated DRB packet bytes of PLMN (1) that eNB transmitted to S-GW
This counter is cumulated when the eNB transmitted User data of PLMN (1) to the S-GW
Y
CC
2s
int
0~21474 83647
-
-
PLMN1EnbQc
Kbyte
The cumulated DRB packet
This counter is
Y
CC
2s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
33
Chapter 2 Counter Description Name
Unit
Description
Trigger
iDLByte
s
bytes of PLMN (1) that eNB received from S-GW
cumulated when the eNB received User data of PLMN (1) from the S-GW
PLMN2EnbQc iULByte
Kbyte s
The cumulated DRB packet bytes of PLMN (2) that eNB transmitted to S-GW
This counter is cumulated when the eNB transmitted User data of PLMN (2) to the S-GW
Y
CC
2s
int
PLMN2EnbQc iDLByte
Kbyte s
The cumulated DRB packet bytes of PLMN (2) that eNB received from S-GW
This counter is cumulated when the eNB received User data of PLMN (2) from the S-GW
Y
CC
2s
PLMN3EnbQc iULByte
Kbyte s
The cumulated DRB packet bytes of PLMN (3) that eNB transmitted to S-GW
This counter is cumulated when the eNB transmitted User data of PLMN (3) to the S-GW
Y
CC
PLMN3EnbQc iDLByte
Kbyte s
The cumulated DRB packet bytes of PLMN (3) that eNB received from S-GW
This counter is cumulated when the eNB received User data of PLMN (3) from the S-GW
Y
PLMN4EnbQc iULByte
Kbyte s
The cumulated DRB packet bytes of PLMN (4) that eNB transmitted to S-GW
This counter is cumulated when the eNB transmitted User data of PLMN (4) to the S-GW
PLMN4EnbQc iDLByte
Kbyte s
The cumulated DRB packet bytes of PLMN (4) that eNB received from S-GW
This counter is cumulated when the eNB received User
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
0~21474 83647
-
-
int
0~21474 83647
-
-
2s
int
0~21474 83647
-
-
CC
2s
int
0~21474 83647
-
-
Y
CC
2s
int
0~21474 83647
-
-
Y
CC
2s
int
0~21474 83647
-
-
83647
34
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
data of PLMN (4) from the S-GW PLMN5EnbQc iULByte
Kbyte s
The cumulated DRB packet bytes of PLMN (5) that eNB transmitted to S-GW
This counter is cumulated when the eNB transmitted User data of PLMN (5) to the S-GW
Y
CC
2s
int
0~21474 83647
-
-
PLMN5EnbQc iDLByte
Kbyte s
The cumulated DRB packet bytes of PLMN (5) that eNB received from S-GW
This counter is cumulated when the eNB received User data of PLMN (5) from the S-GW
Y
CC
2s
int
0~21474 83647
-
-
Collection Time Figure 3. Collection Time for PLMN0EnbQciULByte UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet (PLMN0) Receive
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Uplink DRB Packet (PLMN0) Send - PLMN0EnbQciULByte
35
Chapter 2 Counter Description Figure 4. Collection Time for PLMN1EnbQciULByte UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet (PLMN1) Receive
Uplink DRB Packet (PLMN1) Send - PLMN1EnbQciULByte
Figure 5. Collection Time for PLMN2EnbQciULByte UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet (PLMN2) Receive
Uplink DRB Packet (PLMN2) Send - PLMN2EnbQciULByte
Figure 6. Collection Time for PLMN3EnbQciULByte UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet (PLMN3) Receive
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Uplink DRB Packet (PLMN3) Send - PLMN3EnbQciULByte
36
Chapter 2 Counter Description Figure 7. Collection Time for PLMN4EnbQciULByte UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet (PLMN4) Receive
Uplink DRB Packet (PLMN4) Send - PLMN4EnbQciULByte
Figure 8. Collection Time for PLMN5EnbQciULByte UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet (PLMN5) Receive
Uplink DRB Packet (PLMN5) Send - PLMN5EnbQciULByte
Figure 9. Collection Time for PLMN0EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet (PLMN0) Send - PLMN0EnbQciDLByte
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink DRB Packet (PLMN0) Receive
37
Chapter 2 Counter Description Figure 10. Collection Time for PLMN1EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet (PLMN1) Send - PLMN1EnbQciDLByte
Downlink DRB Packet (PLMN1) Receive
Figure 11. Collection Time for PLMN2EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet (PLMN2) Send - PLMN2EnbQciDLByte
Downlink DRB Packet (PLMN2) Receive
Figure 12. Collection Time for PLMN3EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet (PLMN3) Send - PLMN3EnbQciDLByte
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink DRB Packet (PLMN3) Receive
38
Chapter 2 Counter Description Figure 13. Collection Time for PLMN4EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet (PLMN4) Send - PLMN4EnbQciDLByte
Downlink DRB Packet (PLMN4) Receive
Figure 14. Collection Time for PLMN5EnbQciDLByte UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet (PLMN5) Send - PLMN5EnbQciDLByte
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink DRB Packet (PLMN5) Receive
39
Chapter 2 Counter Description
Ethernet Packet (Pico) This section provides statistics on the number of normal, error and dropped Ethernet packets received from the External Interface (e.g. Backhaul) port. Index Name
Description
PortNum
Port number that can be connected to external device.
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PicoRxLinkUtili zationAvg
%
The average link utilization of packets received outside
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(PicoRxGoodOct etSumBadOctetT ot*8*100*K_UNI T*K_UNIT+((Pico RxUnicastPacket +PicoRxBroadca stPacket+PicoRx MulticastPacket)* 20)*8*100)/(10*P icoRxGoodOctet SumBadOctetCn t*PicoIfSpeed*10 00000)
(sum(PicoRxGoodOcte tSumBadOctetTot)*8*1 00*K_UNIT*K_UNIT+(( sum(PicoRxUnicastPa cket)+sum(PicoRxBroa dcastPacket)+sum(Pic oRxMulticastPacket))* 20)*8*100)/(10*sum(Pi coRxGoodOctetSumB adOctetCnt)*avg(PicoIf Speed)*1000000)
PicoRxLinkUtili zationMax
%
The maximum value of PicoRxLinkUtilization Avg
This counter is updated when PicoRxLinkUtilization Max is collected and it is greater than
Y
GAUG E
Period
float
0~100
-
max(PicoRxLinkUtilizat ionMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
40
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
previously saved minimum value PicoRxErrorRa te
%
The ratio of error packets received outside
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
((PicoRxFifoOver run+PicoRxUnde rsize+PicoRxFra gment+PicoRxO versize+PicoRxJ abber+PicoRxBa dCrc)*100)/(Pico RxUnicastPacket +PicoRxBroadca stPacket+PicoRx MulticastPacket+ PicoRxFifoOverr un+PicoRxUnder size+PicoRxFrag ment+PicoRxOv ersize+PicoRxJa bber+PicoRxBad Crc)
((sum(PicoRxFifoOverr un)+sum(PicoRxUnder size)+sum(PicoRxFrag ment)+sum(PicoRxOve rsize)+sum(PicoRxJab ber)+sum(PicoRxBadC rc))*100)/(sum(PicoRx UnicastPacket)+sum(P icoRxBroadcastPacket )+sum(PicoRxMulticast Packet)+sum(PicoRxFi foOverrun)+sum(PicoR xUndersize)+sum(Pico RxFragment)+sum(Pic oRxOversize)+sum(Pic oRxJabber)+sum(Pico RxBadCrc))
PicoRxGoodO ctet
Mbyt es
The cumulated frame length of normal packets received outside
This counter is cumulated when normal packet is received outside
Y
CC_LL
10 s
int
0~21474 83647
-
-
PicoRxUnicast Packet
count
The cumulated number of Unicast packet received outside
This counter is cumulated when Unicast packet is received outside
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxBroadc astPacket
count
The cumulated number of Broadcast packet received outside
This counter is cumulated when Broadcast packet is received outside
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxMultica
count
The cumulated
This counter is
Y
CC
10 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
41
Chapter 2 Counter Description Name
Unit
stPacket
Description
Trigger
number of Multicast packet received outside
cumulated when Multicast packet is received outside
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
PicoRxFifoOve rrun
count
The cumulated number of dropped Ethernet frames received outside due to buffer resource shortage
This counter is cumulated when the received packet is dropped by the lack of Buffer resource
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxUndersi ze
count
The cumulated number of error packets received outside that are undersize.
This counter is cumulated when the received packet is Undersize packet
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxFragme nt
count
The cumulated number of error packets received outside that are fragmented.
This counter is cumulated when the received packet is Fragment packet
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxOversiz e
count
The cumulated number of error packets received outside that are oversize.
This counter is cumulated when the received packet is Oversize packet
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxJabber
count
The cumulated number of error packets received outside that are jabber.
This counter is cumulated when the received packet is Jabber packet
Y
CC
10 s
int
0~21474 83647
-
-
PicoRxBadCrc
count
The cumulated number of CRC error frames among error
This counter is cumulated when the received packet is
Y
CC
10 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
42
Chapter 2 Counter Description Name
Unit
Description
Trigger
Ethernet frames received outside
CRC Error packet
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PicoRxGoodO ctetSumBadOc tetAvg
Mbyt es
The average value of the total frame length of normal and abnormal packets received
This counter is calculated when measurement period comes.
-
GAUG E
10 s
int
0~21474 83647
PicoRxGoodOcte tSumBadOctetTo t/PicoRxGoodOct etSumBadOctet Cnt
sum(PicoRxGoodOctet SumBadOctetTot)/sum (PicoRxGoodOctetSu mBadOctetCnt)
PicoRxGoodO ctetSumBadOc tetMax
Mbyt es
The maximum value of PicoRxGoodOctetSu mBadOctetAvg
This counter is updated when RxGoodOctetSumBa dOctetAvg is collected and it is greater than previous maximum value
-
GAUG E
10 s
int
0~21474 83647
-
max(PicoRxGoodOctet SumBadOctetMax)
PicoRxGoodO ctetSumBadOc tetTot
Mbyt es
The cumulated number that indicates the sum of the normal and abnormal packets among those received outside.
This counter is updated when normal packet or Bad packet are received
-
GAUG E
10 s
int
0~21474 83647
-
-
PicoRxGoodO ctetSumBadOc tetCnt
count
The collection count of PicoRxGoodOctetSu mBadOctetAvg
This counter is cumulated by 1 when RxGoodOctetSumBa dOctetAvg is collected
-
GAUG E
10 s
int
0~21474 83647
-
-
PicoTxLinkUtili zationAvg
%
The average link utilization of packets transmitted
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(PicoTxGoodOct etSumBadOctetT ot*8*100*K_UNI T*K_UNIT+((Pico TxUnicastPacket +PicoTxBroadca stPacket+PicoTx MulticastPacket)*
(sum(PicoTxGoodOcte tSumBadOctetTot)*8*1 00*K_UNIT*K_UNIT+(( sum(PicoTxUnicastPac ket)+sum(PicoTxBroad castPacket)+sum(Pico TxMulticastPacket))*20 )*8*100)/(10*sum(Pico
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
43
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula 20)*8*100)/(10*P icoTxGoodOctet SumBadOctetCn t*PicoIfSpeed*10 00000)
Hourly, Daily, Monthly Formula TxGoodOctetSumBad OctetCnt)*avg(PicoIfSp eed)*1000000)
PicoTxLinkUtili zationMax
%
The maximum value of TxLinkUtilizationAvg
This counter is update when PicoTxLinkUtilization Avg is collected and it is greater than previous maximum value
Y
GAUG E
Period
float
0~100
-
max(PicoTxLinkUtilizati onMax)
PicoTxErrorRa te
%
The ratio of error packets transmitted
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(PicoTxUnderflo w+PicoTxDeferre d+PicoTxECollisi ons+PicoTxSColl isions+PicoTxMC ollisions)*100/(Pi coTxUnicastPack et+PicoTxBroadc astPacket+PicoT xMulticastPacket +PicoTxUnderflo w+PicoTxDeferre d+PicoTxECollisi ons+PicoTxSColl isions+PicoTxMC ollisions)
(sum(PicoTxUnderflow )+sum(PicoTxDeferred )+sum(PicoTxECollisio ns)+sum(PicoTxSCollis ions)+sum(PicoTxMCol lisions))*100/(sum(Pico TxUnicastPacket)+sum (PicoTxBroadcastPack et)+sum(PicoTxMultica stPacket)+sum(PicoTx Underflow)+sum(PicoT xDeferred)+sum(PicoT xECollisions)+sum(Pic oTxSCollisions)+sum( PicoTxMCollisions))
PicoTxGoodOc tet
Mbyt es
The cumulated total frame length of packets transmitted outside.
This counter is cumulated when packet is transmitted outside
Y
CC_LL
10 s
int
0~21474 83647
-
-
PicoTxUnicast
count
The cumulated
This counter is
Y
CC
10 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
44
Chapter 2 Counter Description Name
Unit
Packet
Description
Trigger
number of unicast packets transmitted outside.
cumulated when Unicast packet is transmitted outside
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
PicoTxBroadca stPacket
count
The cumulated number of broadcast packets transmitted outside.
This counter is cumulated when Broadcast packet is transmitted outside
Y
CC
10 s
int
0~21474 83647
-
-
PicoTxMulticas tPacket
count
The cumulated number of multicast packets transmitted outside.
This counter is cumulated when Multicast packet is transmitted outside
Y
CC
10 s
int
0~21474 83647
-
-
PicoTxUnderfl ow
count
The cumulated number of packets that had an underflow among the packets transmitted outside.
This counter is cumulated when there is an underflow packet among packets transmitted outside.
Y
CC
10 s
int
0~21474 83647
-
-
PicoTxDeferre d
count
The cumulated number of delayed transmission packets due to media busy status when ports were open in halfduplex mode among the packets transmitted outside.
This counter is cumulated when there is a delayed packet due to media busy status when ports were open in half-duplex mode among the packets transmitted outside.
Y
CC
10 s
int
0~21474 83647
-
-
PicoTxECollisi ons
count
The cumulated number of cancelled transmission packets due to excessive collision when ports were open in halfduplex mode among
This counter is cumulated when there is a cancelled packet due to excessive collision when ports were open in half-duplex
Y
CC
10 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
45
Chapter 2 Counter Description Name
Unit
Description
Trigger
the packets transmitted outside.
mode among the packets transmitted outside.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PicoTxSCollisi ons
count
The cumulated number of packets that had a single collision that was detected before their transmission to media.
This counter is cumulated when, among packets transmitted outside, there is a packet that had a single collision that was detected before its transmission to media.
Y
CC
10 s
int
0~21474 83647
-
-
PicoTxMCollisi ons
count
The cumulated number of packets that had multiple collisions that were detected before their transmission to media.
This counter is cumulated when, among packets transmitted outside, there is a packet that had multiple collisions that were detected before its transmission to media.
Y
CC
10 s
int
0~21474 83647
-
-
PicoTxGoodOc tetSumBadOct etAvg
Mbyt es
The average number of the total frame length of normal and abnormal packets transmitted
This counter is calculated when measurement period comes.
-
GAUG E
10 s
int
0~21474 83647
PicoTxGoodOcte tSumBadOctetTo t/PicoTxGoodOct etSumBadOctet Cnt
sum(PicoTxGoodOctet SumBadOctetTot)/sum (PicoTxGoodOctetSum BadOctetCnt)
PicoTxGoodOc tetSumBadOct etMax
Mbyt es
The maximum value of PicoTxGoodOctetSu mBadOctetMax
This counter is updated when PicoTxGoodOctetSu mBadOctetAvg is collected and it is
-
GAUG E
10 s
int
0~21474 83647
-
max(PicoTxGoodOctet SumBadOctetMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
46
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
greater than previous maximum value PicoTxGoodOc tetSumBadOct etTot
Mbyt es
The cumulated number that indicates the sum of the normal and abnormal packets among the packets transmitted to the the outside.
This counter is cumulated when a normal packet or bad packet is transmitted outside.
-
GAUG E
10 s
int
0~21474 83647
-
-
PicoTxGoodOc tetSumBadOct etCnt
count
The collection count of PicoTxGoodOctetSu mBadOctetAvg
This counter is cumulated by 1 when PicoTxGoodOctetSu mBadOctetAvg is collected
-
GAUG E
10 s
int
0~21474 83647
-
-
PicoIfSpeed
Mbps
The measured value of the interface speed.
This counter is modified when the interface speed settings are changed.
-
OW
10 s
int
0~21474 83647
-
avg(PicoIfSpeed)
PicoRxThruPe ak
Mbps
The maximum value of the 1-second peak bandwidth of packets received outside.
This counter is modified when the 1second bandwidth of packets received outside is greater than the previous value.
Y
OW
10 s
float
0~3.4*10 ^38
-
max(PicoRxThruPeak)
PicoTxThruPe ak
Mbps
The maximum value of the 1-second peak bandwidth of packets transmitted outside.
This counter is modified when the 1second bandwidth of packets transmitted outside is greater than the previous value.
Y
OW
10 s
float
0~3.4*10 ^38
-
max(PicoTxThruPeak)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
47
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PicoRxThruPe akCnt
count
The collection count of PicoRxThruPeak
This counter is cumulated when PicoRxThruPeak is collected
-
OW
10 s
int
0~21474 83647
-
-
PicoTxThruPe akCnt
count
The collection count of PicoTxThruPeak
This counter is cumulated when PicoTxThruPeak is collected
-
OW
10 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
48
Chapter 2 Counter Description
Ethernet Packet per VPN This section provides statistics on transmitting/receiving for VPN. Index Name
Description
VPNNum
The index of IPSec VPN Tunnel
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
VPNRxOctet
Mbytes
The cumulated number of octet unit that corresponds to the length of IPSec packets that were received through the IPSec tunnel.
This counter is cumulated when IPSec packet transmission from the other end of the IPSec tunnel to the eNB is valid.
Y
CC_LL
10 s
int
0~21474 83647
-
-
VPNRxPacket
count
The cumulated number of IPSec packets received through the IPSec tunnel.
This counter is cumulated when IPSec packet transmission from the other end of the IPSec tunnel to the eNB is valid.
Y
CC
10 s
int
0~21474 83647
-
-
VPNRxDropPack et
count
The cumulated number of IPSec packets discarded after being received through the IPSec tunnel.
This counter is cumulated when IPSec packet transmission from the other end of the IPSec tunnel to the eNB is
Y
CC
10 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
49
Chapter 2 Counter Description Name
Unit
Description
VPNTxOctet
Mbytes
The cumulated number of octet unit that corresponds to the length of IPSec packets transmitted through the IPSec tunnel.
VPNTxPacket
count
VPNTxDropPack et
count
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when IPSec packet transmission from the eNB to the other end of the IPSec tunnel is valid.
Y
CC_LL
10 s
int
0~21474 83647
-
-
The cumulated number of IPSec packets transmitted through the IPSec tunnel.
This counter is cumulated when IPSec packet transmission from the eNB to the other end of the IPSec tunnel is valid.
Y
CC
10 s
int
0~21474 83647
-
-
The cumulated number of IPSec packets discarded before being transmitted through the IPSec tunnel.
This counter is cumulated when IPSec packet transmission from the eNB to the other end of the IPSec tunnel is invalid.
Y
CC
10 s
int
0~21474 83647
-
-
invalid.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
50
Chapter 2 Counter Description
RRC The following figure shows the statistical definition and message flow for each stage of the Idle to Active (Service Request) procedure by the UE, which allows to identify the overall handling of the RRC/E-RAB/S1 SIG statistics. Figure 15. RRC/E-RAB/S1 SIG Statistics Processing UE
eNB
EPC
MME
S/GW
1) Random Access Procedure 2) RRCConnectionRequest 3) RRCConnectionSetup
[Step 1] RRC establishment
4) RRCConnectionSetupComplete (SERVICE REQUEST)
5) Initial UE Message (SERVICE REQUEST)
6) Authentication/NAS Security Setup
[Step 2] S1SIG setting
7) INITIAL CONTEXT SETUP REQUEST (SERVICE ACCEPT)
8) SecurityModeCommand 9) SecurityModeComplete 10) RRCConnectionReconfiguration (SERVICE ACCEPT)
[Step 3] E-RAB establishment
11) RRCConnectionReconfiguration Complete Uplink data
Uplink data 12) INITIAL CONTEXT SETUP RESPONSE
13) Modify Bearer Request 14) Modify Bearer Response
Downlink data
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink data
51
Chapter 2 Counter Description
Step
Description
1)
The UE performs the Random Access procedure with the eNB.
2)-4)
The UE transmits the NAS SERVICE REQUEST message to the MME. The SERVICE REQUEST message is encapsulated in an RRC message transmitted to the eNB.
5)
The Pico eNB includes the SERVICE REQUEST message in the INITIAL UE message, which is an S1-AP Control message, and transmits it to the MME.
6)
If there is no UE context for the UE in the network, the integrity is not protected for the ATTACH REQUEST message, or the integrity check fails, an authentication and an NAS security setup are always performed. The UE performs the EPS AKA procedure (TS 33.401, 6.1.1) with the MME. The MME sets up an NAS security association with the UE using the NAS SMC procedure (TS 33.401, 7.2.4.4).
7)
The MME transmits the S1-AP Initial Context Setup Request message to the eNB. This step activates both the radio bearer and S1 bearer for all active EPS bearers.
8)-11)
The eNB sets up the RRC radio bearers. The user plane security is set up at this step. The uplink data from the UE can be sent to the S-GW by the S-GW. The eNB transmits the uplink data to the S-GW, and then the S-GW transmits it to the P-GW.
12)
The Pico eNB transmits the INITIAL CONTEXT SETUP RESPONSE message (S1-AP) to the MME.
13)-14)
For each PDN connection, the MME transmits the Modify Bearer Request message to the S-GW. Now, the S-GW can transmit the downlink data to the UE. The S-GW transmits the Modify Bearer Response message to the MME.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
52
Chapter 2 Counter Description
RRC Connection Establishment This section provides access statistics between RRC connection request and RRC connection setup completions collected for each cell. The access call is identified by the establishment cause within the RRC connection request message initially informed by the UE. (3GPP TS 36.331) Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause
RRC Connection Establishment Cause 0: emergency (Emergency call connection) 1: highPriorityAccess (Access by the UE with a specific access class) 2: mt_Access (Access by the UE due to paging received) 3: mo_Signaling (Access by the UE due to attach) 4: mo_Data (Access by the UE due to service request) 5: delay_tolerant_access: Access by the delay tolerant access
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstab Att
count
The cumulated number of receiving RRCConnectionRequest from the UE
This counter is cumulated when the eNB received the RRCConnectionRequest from the UE
Y
CC
event
int
0~21 4748 3647
-
-
ConnEstab Succ
count
The cumulated number of receiving RRCConnectionSetupCompl
This counter is cumulated when the eNB received the RRCConnectionSetupComplete
Y
CC
event
int
0~21 4748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
53
Chapter 2 Counter Description Name
Unit
Description
Trigger
ete in the RRC connection establishment Procedure from the UE
in the RRC connection establishment Procedure from the UE
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 3647
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstab Fail_CpCc To
count
The cumulated number when a call is released due to call control timeout in the RRC connection establishment Procedure because of not receiving response message from the protocol blocks (MAC, RLC, PDCP, GTP)
This counter is cumulated when a call is released due to call control timeout in the RRC connection establishment Procedure because of not receiving response message from the protocol blocks (MAC, RLC, PDCP, GTP)
Y
CC
event
int
0~21 4748 3647
-
-
ConnEstab Fail_CpCc Fail
count
The cumulated number when a call is released due to reset notification (eNB failure or block restart) in the RRC connection establishment Procedure
This counter is cumulated in the following cases. This counter is cumulated when the eNB releases a call due to ECMB reset during RRC connection establishment Procedure after transmitted RRCConnectionSetup to UE This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during RRC connection establishment procedure. This counter is cumulated when the eNB releases the call because mismatches on the UE have occurred both
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
54
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
between the ECCB and RLC and between the ECCB and MAC in the execution of an audit on UE information after the eNB has transmitted an RRCConnectionSetup to the UE during RRC connection establishment Procedure. This counter is cumulated when the eNB releases the call due to invalid MME after receiving the RRCConnectionSetupComple te message from UE during RRC connection establishment Procedure. ConnEstab Fail_UpMa cFail
count
The cumulated number when a call is released due to the failure between MAC and ECCB block in the RRC connection establishment Procedure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated in the following cases. This counter is cumulated when the eNB releases a call due to receiving a failure message from the MAC after the eNB transmits RRCConnectionSetup to the UE during the RRC connection establishment procedure. This counter is cumulated when the eNB releases a call since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information after transmitting
55
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
RRCConnectionSetup to the UE during the RRC connection establishment procedure. ConnEstab Fail_UpPd cpFail
count
The cumulated number when a call is released due to the failure between PDCP and ECCB block in the RRC connection establishment Procedure
This counter is cumulated when the eNB releases a call due to receiving a Fail message from the PDCP after the eNB transmits RRCConnectionSetup to the UE during the RRC connection establishment procedure.
Y
CC
event
int
0~21 4748 3647
-
-
ConnEstab Fail_UpRlc Fail
count
The cumulated number when a call is released due to the failure between RLC and ECCB block in the RRC connection establishment Procedure
This counter is cumulated in the following cases. This counter is cumulated when the eNB releases a call due to receiving a Fail message from the RLC after the eNB transmits RRCConnectionSetup to the UE during the RRC connection establishment procedure. This counter is cumulated when the eNB releases a call since a mismatch with the RLC occurs in the execution of an audit with the DSP after transmitting RRCConnectionSetup to the UE during the RRC connection establishment procedure.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
56
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstab Fail_RrcSi gTo
count
The cumulated number when a call is released due to timeout in the RRC connection establishment Procedure because of not receiving RRCConnectionSetupCompl ete Message.
This counter is cumulated when the eNB releases a call due to a timeout that occurs since the eNB transmits RRCConnectionSetup to the UE and does not receive RRCConnectionSetupComplete from the UE during the RRC connection establishment procedure.
Y
CC
event
int
0~21 4748 3647
-
-
ConnEstab Fail_S1apL inkFail
count
The cumulated number when a call is released due to the S1AP link in the RRC connection establishment Procedure, because the S1AP linke status is changed to Out of service.
This counter is cumulated in the following cases. This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) after transmitting RRCConnectionSetup to the UE during RRC connection establishment Procedure. This counter is cumulated when eNB released call due to SCTB reset during RRC connection establishment Procedure after transmitting RRCConnectionSetup message to UE
Y
CC
event
int
0~21 4748 3647
-
-
ConnEstab Fail_S1ap SigFail
count
The cumulated number when a call is released due to receiving S1AP reset from MME in the RRC connection establishment Procedure
This counter is cumulated when a call is released due to receiving S1AP reset from MME in the RRC connection establishment Procedure
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
57
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstab Reject_Cp CcFail
count
The cumulated number when a call cannot be accepted because the cell is barred after receiving the RRC Connection Request message.
This counter is cumulated in the following cases. This counter is cumulated when the eNB transmits RRCConnectionReject to the UE since the eNB receives RRCConnectionRequest from the UE but the operational state of the cell (operational state of RTRV-CELL-STS) is Disabled and the RRC connection establishment procedure is judged unable to be performed. This counter is cumulated when the eNB transmits RRCConnectionReject to the UE since the eNB receives RRCConnectionRequest from the UE but the internal resource allocation in eNB fails and the RRC connection establishment procedure is judged unable to be performed. This counter is cumulated when the eNB tranmitted the RRCConnectionReject to UE due to invalid MME after receiving RRCConnectionRequest message during RRC connection establishment Procedure
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
58
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstab Reject_Cp CapaCacF ail
count
The cumulated number when a call cannot be accepted due to Call Admission Control (CAC based on Call Count per eNB or CAC based on Call Count per Cell ) after receiving the RRC Connection Request message in the RRC connection establishment Procedure, and the eNB transmitted RRCConnectionReject message to UE.
This counter is cumulated when a call cannot be accepted due to Call Admission Control (CAC based on Call Count per eNB or CAC based on Call Count per Cell ) after receiving the RRC Connection Request message in the RRC connection establishment Procedure, and the eNB transmitted RRCConnectionReject message to UE.
Y
CC
event
int
0~21 4748 3647
-
-
ConnEstab Reject_S1 apMmeOvl d
count
The cumulated number when a call cannot be accepted after receiving RRCConnectioRequest message from UE due to MME overload in the RRC connection establishment Procedure and then the eNB transmitted RRCConnectionReject message to UE.
This counter is cumulated when the eNB transmits RRCConnectionReject to the UE since the eNB receives RRCConnectionRequest from the UE, but the UE-Identity is STMSI and MME state that allocates S-TMSI is OverLoad, or the UE-Identity is a random value and all MME states are OverLoad, so the RRC connection establishment procedure is judged unable to be performed.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
59
Chapter 2 Counter Description
Collection Time (Success) Figure 16. Collection Time for RRC Connection Establishment UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
2
ConnEstabSucc
RRCConnectionSetup
RRCConnectionSetupComplete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
60
Chapter 2 Counter Description
Collection Time (Failure) Figure 17. Collection Time for ConnEstabFail_CpCcTo eNB UE
MAC/RLC/PDCP
ECCB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup Timer RRCConnectionSetup Success Message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
X
2
Failure - ConnEstabFail_CpCcTo
61
Chapter 2 Counter Description Figure 18. Collection Time for ConnEstabFail_CpCcFail (1) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest 1
ConnEstabAtt
RRCConnectionSetup ECMB reset 2
Failure - ConnEstabFail_CpCcFail
Figure 19. Collection Time for ConnEstabFail_CpCcFail (2) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup Cell disabled 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabFail_CpCcFail
62
Chapter 2 Counter Description Figure 20. Collection Time for ConnEstabFail_CpCcFail (3) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC 2
Failure - ConnEstabFail_CpCcFail
Figure 21. Collection Time for ConnEstabFail_CpCcFail (4) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup RRCConnectionSetupComplete Available MME doesn’t exist 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabFail_CpCcFail
63
Chapter 2 Counter Description Figure 22. Collection Time for ConnEstabFail_UpMacFail (1) eNB ECCB
MAC
UE
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
2
Failure - ConnEstabFail_UpMacFail
RRCConnectionSetup Fail Message
Figure 23. Collection Time for ConnEstabFail_UpMacFail (2) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup A Mismatch of UE information occurred in the execution of audit between the ECCB and MAC 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabFail_UpMacFail
64
Chapter 2 Counter Description Figure 24. Collection Time for ConnEstabFail_UpPdcpFail eNB ECCB
PDCP
UE
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
2
Failure - ConnEstabFail_UpPdcpFail
RRCConnectionSetup Fail Message
Figure 25. Collection Time for ConnEstabFail_UpRlcFail (1) eNB UE
RLC
ECCB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
2
Failure - ConnEstabFail_UpRlcFail
RRCConnectionSetup Fail Message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
65
Chapter 2 Counter Description Figure 26. Collection Time for ConnEstabFail_UpRlcFail (2) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup A Mismatch of UE information occurred in the execution of audit between the ECCB and RLC 2
Failure - ConnEstabFail_UpRlcFail
Figure 27. Collection Time for ConnEstabFail_RrcSigTo UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup Timer RRCConnectionSetup RRCConnectionSetupComplete
X
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
2
Failure - ConnEstabFail_RrcSigTo
66
Chapter 2 Counter Description Figure 28. Collection Time for ConnEstabFail_S1apLinkFail (1) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup S1 AP Link is Out of Service Status
X 2
Failure - ConnEstabFail_S1apLinkFail
Figure 29. Collection Time for ConnEstabFail_S1apLinkFail (2) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup SCTB reset 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabFail_S1apLinkFail
67
Chapter 2 Counter Description Figure 30. Collection Time for ConnEstabFail_S1apSigFail UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
RRCConnectionSetup RESET 2
Failure - ConnEstabFail_S1apSigFail
Figure 31. Collection Time for ConnEstabReject_CpCcFaill (1) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
Cell disabled RRCConnectionReject 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabReject_CpCcFail
68
Chapter 2 Counter Description Figure 32. Collection Time for ConnEstabReject_CpCcFaill (2) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
Internal resource allocation Failure RRCConnectionReject 2
Failure - ConnEstabReject_CpCcFail
Figure 33. Collection Time for ConnEstabReject_CpCcFail (3) UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
Available MME doesn’t exist RRCConnectionReject 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabReject_CpCcFail
69
Chapter 2 Counter Description Figure 34. Collection Time for ConnEstabReject_CpCapaCacFail UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
1
ConnEstabAtt
CAC based on Call Count per eNB Fail or CAC based on Call Count per Cell Fail RRCConnectionReject 2
Failure - ConnEstabReject_CpCapaCacFail
Figure 35. Collection Time for ConnEstabReject_S1apMmeOvld UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
ConnEstabAtt
1
MME OverLoad RRCConnectionReject 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnEstabReject_S1apMmeOvld
70
Chapter 2 Counter Description
For statistics on RRC connection establishment, Attempt, Success, Fail and Reject statistics are counted. Attempt statistic is counted when the RRC Connection Request message is received. Success statistic is counted when the messages up to RRC Connection Setup Complete are successfully received. When a timeout or internal failure occurs during the procedure from 1 to 2 in the figure above, it is counted as Fail, returning the cause value. Reject statistic is counted when the eNB determines that the call cannot be accepted after receiving the RRC Connection Request message, and the applicable cause value is recorded.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
71
Chapter 2 Counter Description
RRC Connection Reconfiguration This section provides statistics on the RRC Connection Reconfiguration’s count for each cell. There is no Fail statistic as the RRC Connection Reconfiguration message is transmitted down from the SeNB and the RRC Connection Reconfiguration Complete message is transmitted to the TeNB. In this case, the attempt and success counts in the reconfiguration statistics for the eNB can be different. (3GPP TS 36.331) Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReconf igAtt
count
The cumulated number when the eNB transmits the RRCConnectionReconfigurat ion to UE
This counter is cumulated when the eNB transmitted the RRCConnectionRec onfiguration to UE
Y
CC
event
int
0~2147483 647
-
-
ConnReconf igSucc
count
The cumulated number when the eNB received the RRCConnectionReconfigurat ionComplete from UE
This counter is cumulated when the eNB received the RRCConnectionRec onfigurationComplet e from the UE.
Y
CC
event
int
0~2147483 647
-
-
SCellAddCo unt
count
The cumulated number of Scell (Secondary Cell) that is included in the
This counter is cumulated by the number of
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
72
Chapter 2 Counter Description Name
SCellReleas eCount
Unit
count
Description
Trigger
sCellToAddModList of RRCConnectionReconfigurat ion when the eNB transmits RRCConnectionReconfigurat ion message for CA (Carrier Aggregation) to the UE
Secondary Cells (SCell) included in sCellToAddModList of RRCConnectionRec onfiguration when the eNB transmits RRCConnectionRec onfiguration to the UE for Carrier Aggregation (CA).
The cumulated number of Scell (Secondary Cell) that is included in the sCellToReleaseList of RRCConnectionReconfigurat ion when the eNB transmits RRCConnectionReconfigurat ion message for CA (Carrier Aggregation) to the UE
This counter is cumulated by the number of Secondary Cells (SCell) included in sCellToReleaseList of RRCConnectionRec onfiguration when the eNB transmits RRCConnectionRec onfiguration to the UE for Carrier Aggregation (CA).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483 647
-
-
73
Chapter 2 Counter Description
Collection Time Figure 36. Collection Time for ConnReconfigAtt UE
eNB
MME
S/GW
MME
S/GW
MME
S/GW
RRC_CONNECTED RRCConnectionReconfiguration
1
ConnReconfigAtt
Figure 37. Collection Time for ConnReconfigSucc UE
eNB RRCConnectionReconfiguration Complete
1
ConnReconfigSucc
Figure 38. Collection Time for SCellAddCount UE
eNB RRC_CONNECTED RRCConnectionReconfiguration (with sCellToAddModList)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
SCellAddCount
74
Chapter 2 Counter Description Figure 39. Collection Time for SCellReleaseCount UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReconfiguration (with sCellToReleaseList)
1
SCellReleaseCount
The transmission of the RRC Connection Reconfiguration to the UE is counted as Attempt, while the receipt of RRC Connection Reconfiguration Complete from the UE is counted as Success. Upon handover, the source eNB transmits RRC Connection Reconfiguration (handover command) to the UE; the UE transmits RRC Connection Reconfiguration Complete (handover command complete) to the target eNB. Therefore, a fail count is not returned because it is not possible to determine transmission failure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
75
Chapter 2 Counter Description
RRC Connection Re-establishment This section provides statistics as shown below, when a RRC Reestablishment cause occurs with the UE in RRC connected state, statistics on the RRC connection Reestablishment are collected for each cell. (3GPP TS 36.331) Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
ReEstabCause
RRC Connection Reestablishment Cause 0 (reconfigurationFailure): Reestablishment occurs due to reconfiguration failure 1 (handoverFailure): Reestablishment occurs due to handover failure 2 (otherFailure): Reestablishment occurs due to other failures 3: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEsta bAtt
count
The cumulated number of RRCConnectionReestablishmentRequest messages received from the UE.
This counter is cumulated when the eNB receives an RRCConnectionReestablishmentRequest message from the UE.
Y
CC
event
int
0~2 147 483 647
-
-
ConnReEsta bSucc
count
The cumulated number of RRCConnectionReestablishmentComplete messages received from the UE during the RRC connection re-establishment
This counter is cumulated when eNB receives RRCConnectionReestablishmentComplete message as a result of transmitting
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
76
Chapter 2 Counter Description Name
ConnReEsta bFail_CpCc Fail
Unit
count
Description
Trigger
procedure.
RRCConnectionReestablishment request to the UE during the RRC connection reestablishment procedure.
The cumulated number when the RRC connection reestablishment procedure fails due to a change of eNB status or eNB internal resource allocation fails.
This counter is cumulated in the following cases. This counter is cumulated when the eNB releases a call due to ECMB reset after the eNB transmits an RRCConnectionReestablishment request to the UE during the RRC connection reestablishment procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB. The operational state of the cell (operational State of RTRVCELL-STS) gets changed due to a disabilty of the eNB transmission. RRC connection is being reestablished to the UE. This counter is cumulated when the eNB releases the call because mismatches on the UE have occurred both between the ECCB and RLC and between the ECCB and MAC in the
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
77
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
execution of an audit on UE information after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases a call since a failure occurs during internal resource allocation in eNB for transmitting RRCConnectionReestablishment to the UE during the RRC connection re-establishment procedure. ConnReEsta bFail_UpMa cFail
count
The cumulated number of failures to perform the RRC connection re-establishment procedure due to a failure that has occurred between the MAC and ECCB during the said procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB releases the call as a result of receiving a Fail message from the MAC after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call when there is a mismatch between the ECCB and MAC in the execution of the audit of UE information after the eNB has transmitted an RRCConnectionReestablishment to the UE.
78
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEsta bFail_UpPdc pFail
count
The cumulated number of failures to perform the RRC connection re-establishment procedure due to a failure that has occurred between the PDCP and ECCB during the said procedure.
This counter is cumulated when the eNB releases the call as a result of receiving a internal failure message (msgCpdcpControlFailure) from the PDCP after the eNB has transmitted an RRCConnectionReestablishment to the UE. When receiving invalid parameter (in case when callid, rbid and lochType are not within the range) from ECCB block in eNB, PDCP transmits Failure Message to ECCB block.
Y
CC
event
int
0~2 147 483 647
-
-
ConnReEsta bFail_UpRlc Fail
count
The cumulated number of failures to perform the RRC connection re-establishment procedure due to a failure that has occurred between the RLC and ECCB during the said procedure.
This counter is cumulated when the eNB releases the call as a result of receiving a internal failure message (msgCrlcConfigFailure or msgCrlcControlFailure) from the RLC after the eNB has transmitted an RRCConnectionReestablishment to the UE. When invalid parameter (in case when callid, rbid, lochID and lochType are not within the range) is received from ECCB block in eNB or when there are not much resources in the RLC, the RLC transmits
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
79
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
Failure Message to ECCB block. This counter is cumulated when the eNB releases the call because a mismatch with the RLC has occurred in the execution of an audit with the DSP after the eNB has transmitted an RRCConnectionReestablishment to the UE. ConnReEsta bFail_RrcSig To
count
The cumulated number of failures to perform the RRC connection re-establishment procedure due to a timeout that has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, RLC, MAC) or RRC connection reestablishment complete message from the UE during the said procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB releases the call due to a timeout has occurred as a result of not being able to receive an RRCConnectionReestablishmentComplete message from the UE after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call due to a timeout has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, RLC, MAC) after the eNB has transmitted an RRCConnectionReestablishment to the UE.
80
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEsta bFail_S1apL inkFail
count
The cumulated number of failures to perform the RRC connection re-establishment procedure due to a change of S1AP link status to ‘Out of Service’ during the said procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call due to an SCTB reset, occurred after the eNB has transmitted an RRCConnectionReestablishment request to the UE.
Y
CC
event
int
0~2 147 483 647
-
-
ConnReEsta bFail_S1apL SigFail
count
The cumulated number of failures to perform the RRC connection re-establishment procedure as a result of receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the said procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME after the eNB has transmitted RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME after the eNB has transmitted an RRCConnectionReestablishment to the UE.
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
81
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEsta bReject_Cp CcFail
count
The cumulated number of RRCConnectionReestablishmentReject messages transmitted to the UE since the RRC connection reestablishment procedure has been judged unable to be performed after receiving RRCConnectionReestablishmentRequest from the UE.
This counter is cumulated when the eNB transmits the RRCConnectionReestablishmentReject message to the UE of it being judged to be unable to perform RRC connection reestablishment Procedure due to the lack of context information about the UE even though the eNB has received an RRCConnectionReestablishmentRequest message from the UE. This counter is cumulated when the eNB transmits to RRC connection reestablishment rejects message to the UE because the RRC connection reestablishment procedure has been judged unable to perform. As a result of which the eNB receives a RRC connection reestablishment request message before transmitting to MME a INITIAL CONTEXT SETUP RESPONSE message, which happens when the UE is not completely attached.
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
82
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when the eNB transmits an RRC connection reestablishment rejects message to the UE because the RRC connection reestablishment procedure has been judged unable to perform as a result of the eNB receiving a RRC connection reestablishment request message from the UE before receiving a SN STATUS TRANSFER from the source of eNB or receiving a MME STATUS TRANSFER message from MME during the inter-eNB handing over procedure. This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed because, even though the eNB has received from the UE an RRCConnectionReestablishmentRequest to a different cell from the existing cell, the new target Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
83
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
cell is barred (cellBarred of RTRV-CELL-ACS). This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed because, even though the eNB has received from the UE an RRCConnectionReestablishmentRequest to a different cell from the existing cell, the new target cell is in Locked or ShuttingDown status. This counter is cumulated when the eNB transmits the RRCConnectionReestablis hmentReject message to the UE of it being judged to be unable to perform RRC connection reestablishment Procedure due to failure of repremption procedure in the changed Cell even though the eNB has received an RRCConnectionReestablis hmentRequest message from the UE. Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
84
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEsta bReject_Cp CapaCaccF ail
count
The cumulated number of RRCConnectionReestablishmentReject messages transmitted to the UE since the RRC connection reestablishment procedure has been judged unable to be performed by the Call Admission Control (CAC) based on call count per cell operation or the CAC based on DRB count per cell operation after receiving RRCConnectionReestablishmentRequest from the UE.
This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed by the Call Admission Control (CAC) based on call count per cell operation or the CAC based on DRB count per cell operation which in the new target cell; even though the eNB has received from the UE an RRCConnectionReestablishmentRequest, the target cell has changed from the existing cell to a new cell.
Y
CC
event
int
0~2 147 483 647
-
-
ConnReEsta bReject_Cp QosCacFail
count
The cumulated number RRCConnectionReestablishmentReject messages transmitted to the UE since the RRC connection reestablishment procedure has been judged unable to be performed by the Call Admission Control (CAC) based on QoS operation after receiving RRCConnectionReestablishmentRequest from the UE.
This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed by the Call Admission Control (CAC) based on QoS operation in the new target cell even though the eNB has received from the UE an RRCConnectionReestablishmentRequest to a
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
85
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
different cell from the existing cell.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
86
Chapter 2 Counter Description
Collection Time Figure 40. Collection Time for RRC Connection Re-Establishment UE
eNB
MME
S/GW
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest RRCConnectionReestablishment RRCConnectionReestablishment Complete
1
ConnReEstabAtt
2
ConnReEstabSucc
RRC_CONNECTED
Figure 41. Collection Time for ConnReEstabFail_CpCcFail (1) UE
eNB RRC_CONNECTED
RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
RRCConnectionReestablishment ECMB reset 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabFail_CpCcFail
87
Chapter 2 Counter Description Figure 42. Collection Time for ConnReEstabFail_CpCcFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
RRCConnectionReestablishment Cell disabled 2
Failure - ConnReEstabFail_CpCcFail
Figure 43. Collection Time for ConnReEstabFail_CpCcFail (3) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
RRCConnectionReestablishment Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabFail_CpCcFail
88
Chapter 2 Counter Description Figure 44. Collection Time for ConnReEstabFail_CpCcFail (4) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
Internal resource allocation Failure 2
Failure - ConnReEstabFail_CpCcFail
Figure 45. Collection Time for ConnReEstabFail_UpMacFail (1) eNB ECCB
MAC
UE
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
2
Failure - ConnReEstabFail_UpMacFail
RRCConnectionReestablishment Fail Message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
89
Chapter 2 Counter Description Figure 46. Collection Time for ConnReEstabFail_UpMacFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
RRCConnectionReestablishment A mismatch of UE information occurred in the execution of audit between the ECCB and MAC 2
Failure - ConnReEstabFail_UpMacFail
Figure 47. Collection Time for ConnReEstabFail_UpPdcpFail eNB ECCB
PDCP
UE
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
2
Failure - ConnReEstabFail_UpPdcpFail
RRCConnectionReestablishment Fail Message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
90
Chapter 2 Counter Description Figure 48. Collection Time for ConnReEstabFail_UpRlcFail (1) eNB ECCB
RLC
UE
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
2
Failure - ConnReEstabFail_UpRlcFail
RRCConnectionReestablishment Fail Message
Figure 49. Collection Time for ConnReEstabFail_UpRlcFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
RRCConnectionReestablishment A mismatch of UE information occurred in the execution of audit between the ECCB and RLC 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabFail_UpRlcFail
91
Chapter 2 Counter Description Figure 50. Collection Time for ConnReEstabFail_RrcSigTo (1) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
RRCConnectionReestablishment
Timer RRCConnectionReEstablish RRCConnectionReestablishmentComplete
X
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
2
Failure - ConnReEstabFail_RrcSigTo
92
Chapter 2 Counter Description
Figure 51. Collection Time for ConnReEstabFail_RrcSigTo (2) eNB ECCB
MAC/RLC/PDCP
UE
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
RRCConnectionReestablishment
Timer RRCConnectionReEstablish
Success Message
X
2
Failure - ConnReEstabFail_RrcSigTo
Figure 52. Collection Time for ConnReEstabFail_S1apLinkFail (1) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
RRCConnectionReestablishment
S1 AP Link is Out of Service Status
X 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabFail_S1apLinkFail
93
Chapter 2 Counter Description Figure 53. Collection Time for ConnReEstabFail_S1apLinkFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
RRCConnectionReestablishment SCTB reset 2
Failure - ConnReEstabFail_S1apLinkFail
Figure 54. Collection Time for ConnReEstabFail_S1apLSigFail (1) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
RRCConnectionReestablishment S1AP UE CONTEXT RELEASE COMMAND 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabFail_S1apSigFail
94
Chapter 2 Counter Description Figure 55. Collection Time for ConnReEstabFail_S1apLSigFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
RRCConnectionReestablishment RESET 2
Failure - ConnReEstabFail_S1apSigFail
Figure 56. Collection Time for ConnReEstabReject_CpCcFail (1) UE
eNB
MME
RRCConnectionReestablishmentRequest 1
S/GW
ConnReEstabAtt
No context information about the existence of the UE RRCConnectionReestablishmentReject 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabReject_CpCcFail
95
Chapter 2 Counter Description Figure 57. Collection Time for ConnReEstabReject_CpCcFail (2) UE
eNB
MME
S/GW
Attach Procedure is not completed RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
2
Failure - ConnReEstabReject_CpCcFail
RRCConnectionReestablishmentReject
Figure 58. Collection Time for ConnReEstabReject_CpCcFail (3) UE
Target eNB
MME
S/GW
SN STATUS TRANSFER message is yet to be received from the source eNB or MME STATUS TRANSFER message is yet to be received from the MME when inter-eNB handvoer operation is perfomed. RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
2
Failure - ConnReEstabReject_CpCcFail
RRCConnectionReestablishmentReject
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
96
Chapter 2 Counter Description Figure 59. Collection Time for ConnReEstabReject_CpCcFail (4) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
Cell Barred RRCConnectionReestablishmentReject 2
Failure - ConnReEstabReject_CpCcFail
Figure 60. Collection Time for ConnReEstabReject_CpCcFail (5) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
Cell Locked or Shutting Down RRCConnectionReestablishmentReject 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabReject_CpCcFail
97
Chapter 2 Counter Description Figure 61. Collection Time for ConnReEstabReject_CpCcFail (6) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
Pre-emption Fail RRCConnectionReestablishmentReject 2
Failure - ConnReEstabReject_CpCcFail
Figure 62. Collection Time for ConnReEstabReject_CpCapaCacFail UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
1
ConnReEstabAtt
CAC based on Call Count per Cell Fail or CAC based on DRB Count per Cell Fail RRCConnectionReestablishmentReject 2
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnReEstabReject_CoCapaCacFail
98
Chapter 2 Counter Description Figure 63. Collection Time for ConnReEstabReject_CpQosCacFail UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest 1
ConnReEstabAtt
CAC based on QoS Fail RRCConnectionReestablishmentReject 2
Failure - ConnReEstabReject_CpQosCacFail
When RRC Connection Reestablishment Request is received, it is counted as an attempt. If the call context exists in the eNB and the security key value uploaded by the UE matches, RRC Connection Re-establishment is transmitted to the UE; and when RRC Connection Re-establishment Complete is received, it is counted as Success. If a call text does not exist in the eNB or the security key value uploaded by the UE does not match, the RRC Connection Reestablishment Reject is transmitted to the UE and is counted as a Reject. Then, if the RRC Connection Reestablishment Complete is not received, the call is released.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
99
Chapter 2 Counter Description
RRC Connection Release This section provides statistics on the RRC Connection Release for each cell. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease _CpCcNormal
count
The cumulated number when the RRC connection is released normally from the eNB after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released normally from the eNB after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _CpCcTo
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, GTP, RLC, MAC) after the RRC connection establishment procedure
This counter is cumulated when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, GTP, RLC, MAC) after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
100
Chapter 2 Counter Description Name
Unit
ConnRelease _CpCcFail
count
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when the eNB releases a call due to ECMB reset after RRC connection establishment Procedure completed This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRVCELL-STS) is changed to disabled after completing RRC connection establishment Procedure This counter is cumulated when the eNB releases a call since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of UE information after the RRC connection establishment procedure is completed. This counter is cumulated when the eNB releases a call since a failure occurs during internal resource allocation in eNB after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
is completed. The cumulated number when the RRC connection is released from the eNB since the eNB status changes or the eNB internal resource allocation fails after the RRC connection establishment procedure is completed.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
101
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease _UpGtpFail
count
The cumulated number when the RRC connection is released from the eNB since a failure occurs between the GTP and ECCB after the RRC connection establishment procedure is completed.
This counter is cumulated when eNB released RRC Connection due to receiving Fail message from the GTP, after completing RRC connection establishment Procedure
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _UpMacFail
count
The cumulated number when the RRC connection is released from the eNB since a failure occurs between the MAC and ECCB after the RRC connection establishment procedure is completed.
This counter is cumulated when RRC Connection released due to receiving the Fail message from MAC after completing RRC connection establishment Procedure This counter is cumulated when the RRC connection is released since a mismatch on the UE occurs between the ECCB and MAC when the eNB executes an audit of the UE information after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _UpMacUEIn act
count
The cumulated number when the RRC connection is released from the eNB since a timeout occurs in the UE after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC Connection released due to Inactivity Timeout occurs for UE after completed RRC connection establishment Procedure
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease
count
The cumulated number
This counter is cumulated when
Y
CC
event
int
0~21
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
102
Chapter 2 Counter Description Name
Unit
_UpPdcpFail
Description
Trigger
when the RRC connection is released from the eNB since a fail message is received from the PDCP after the RRC connection establishment procedure is completed.
a call is release due to receiving Fail message from the PCDP after completing RRC connection establishment Procedure
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 4748 3647
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease _UpRlcFail
count
The cumulated number when the RRC connection is released from the eNB since a failure occurs between the RLC and ECCB after the RRC connection establishment procedure is completed.
This counter is cumulated when RRC Connection released due to receiving the Fail message from MAC after completing RRC connection establishment Procedure This counter is cumulated when the RRC connection is released since a mismatch on the UE occurs between the ECCB and RLC when the eNB executes an audit of the UE information after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _RrcHcTo
count
The cumulated number when the RRC connection is released since RRCConnectionReconfig urationComplete is not received from the UE during the intra-eNB handover procedure after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released since RRCConnectionReconfiguratio nComplete is not received from the UE during the intra-eNB handover procedure after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
103
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease _RrcSigFail
count
The cumulated number when the RRC connection is released from the eNB due to a duplication check after an RRCConnectionReestablishmentRequest or RRCConnectionRequest is received before the attach process is completed after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released in eNB since the RRC connection reestablishment procedure is judged unable to be performed when the eNB receives RRCConnectionReestablishmentRequest before transmitting INITIAL CONTEXT SETUP RESPONSE to MME since the attach process for the UE is not completed. This counter is cumulated when the RRC connection of an existing call is released in eNB through a duplication check when the eNB receives RRCConnectionRequest and the UE-Identity of RRCConnectionRequest is STMSI while an existing call has the same S-TMSI. This counter is cumulated when the RRC connection of an existing call is released in eNB through a duplication check when the eNB receives RRCConnectionRequest and the UE-Identity of RRCConnectionRequest is a random value while an existing call has the same
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
104
Chapter 2 Counter Description Name
Unit
Description
ConnRelease _RrcSigTo
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive a RRC response message from the UE after the RRC connection establishment procedure is completed.
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
random value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when RRCConnectionReconfigurati onComplete is not received from the UE after the RRC connection establishment procedure is completed and RRCConnectionReconfigurati on is transmitted to the UE. This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when RRCConnectionReestablishmentComplete is not received from the UE after the RRC connection establishment procedure is completed and RRCConnectionReestablishment is transmitted to the UE. This counter is cumulated when the RRC connection is released in eNB after the UE establishment procedure is completed, SecurityModeCommand is transmitted to the UE, and SecurityModeFailure is received from the UE.
105
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when SecurityModeComplete is not received from the UE after the RRC connection establishment procedure is completed and SecurityModeCommand is transmitted to the UE. This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when UECapabilityInformation is not received from the UE after the RRC connection establishment procedure is completed and UECapabilityEnquiry is transmitted to the UE. ConnRelease _CpBhCacFail
count
The cumulated number when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on backhaul bandwidth operation in the RRC connection establishment procedure after the said procedure is completed.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the RRC connection is released in eNB since Call Admission Control (CAC) based on the backhaul bandwidth operation fails in the E-RAB setup or ERAB modify procedure after the RRC connection establishment procedure is completed.
106
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease _CpCapaCac Fail
count
The cumulated number when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation in the RRC connection establishment procedure after the said procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation in the RRC connection establishment procedure after the said procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _CpQosCacF ail
count
The cumulated number when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on QoS operation in the RRC connection establishment procedure after the said procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on QoS operation in the RRC connection establishment procedure after the said procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _S1apCuFail
count
The cumulated number when the RRC connection is released from the eNB due to a S1AP message after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a S1AP message after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease
count
The cumulated number when the RRC
This counter is cumulated when the eNB releases the
Y
CC
event
int
0~21 4748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
107
Chapter 2 Counter Description Name
Unit
_S1apLinkFail
ConnRelease _S1apRoTo
count
Description
Trigger
connection is released from the eNB since the S1AP link status is changed to 'Out of Service' after the RRC connection establishment procedure is completed.
call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) after completing RRC connection establishment Procedure This counter is cumulated when RRC Connection is released due to SCTB reset after completing RRC connection establishment Procedure.
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive an UE CONTEXT RELEASE COMMAND message from MME after the source eNB receives a HANDOVER COMMAND from MME during intra LTE S1 handover or interRAT handover execution.
This counter is cumulated when the RRC connection is released in the source eNB due to a timeout that occurs since the source eNB does not receive an UE CONTEXT RELEASE COMMAND message from MME after receiving HANDOVER COMMAND from MME while intra LTE S1 handover is performed. This counter is cumulated when the RRC connection is released in the source eNB due to a timeout that occurs since the source eNB does not receive an UE CONTEXT RELEASE COMMAND message from MME after receiving HANDOVER COMMAND from MME while
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 3647
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
108
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
inter-RAT (GERAN, UTRA) handover is performed. This counter is cumulated when the RRC connection is released in the source eNB due to a timeout that occurs since the source eNB does not receive an UE CONTEXT RELEASE COMMAND message from MME after receiving S1AP DOWNLINK S1 CDMA2000 TUNNELING (with CDMA2000HO Status: HO Success) from MME while inter-RAT (CDMA2000 HRPD) handover is performed. ConnRelease _S1apSigFail
count
The cumulated number when the RRC connection is released from the eNB since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME or a mismatch occurs between the integrity algorithm and ciphering algorithm of the UE after the RRC connection establishment procedure is completed.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when RRC Connection is released in eNB due to receiving the S1AP UE CONTEXT RELEASE COMMAND from MME after completing RRC connection establishment Procedure This counter is cumulated when RRC Connection is released in eNB due to receiving the S1AP RESET from MME after completing RRC connection establishment Procedure The counter is cumulated when the RRC connection is
109
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
released in eNB since the integrity algorithm of the UE is eia0 but the cipering algorithm is not eea0 when UE security capabilities are acquired after the RRC connection establishment procedure is completed. ConnRelease _S1apSigTo
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred since an INITIAL CONTEXT SETUP RESPONSE message is not received from the UE after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a timeout that has occurred since an INITIAL CONTEXT SETUP RESPONSE message is not received from the UE after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _X2apCuFail
count
The cumulated number when the RRC connection is released from the eNB due to a X2AP message in the RRC connection establishment procedure after the said procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a X2AP message in the RRC connection establishment procedure after the said procedure is completed.
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease _X2apLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
ConnRelease
count
The cumulated number
This counter is cumulated when
Y
CC
event
int
0~21
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
110
Chapter 2 Counter Description Name
Unit
_X2apRoTo
ConnRelease _X2apSigFail
count
Description
Trigger
when the RRC connection is released from the source eNB due to a timeout that has occurred since the source eNB is not able to receive an UE CONTEXT RELEASE message from the target eNB after receiving HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
the RRC connection is released from the source eNB due to a timeout that has occurred since the source eNB is not able to receive an UE CONTEXT RELEASE message from the target eNB after receiving HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
The cumulated number when the RRC connection is released from the source eNB since a reset occurs in the X2 interface between the source eNB and target eNB after receiving a HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
This counter is cumulated when the RRC connection is released from the source eNB since a reset occurs in the X2 interface between the source eNB and target eNB after receiving a HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 4748 3647
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
111
Chapter 2 Counter Description
Collection Time Figure 64. Collection Time for ConnRelease_CpCcNormal UE
eNB
MME
S/GW
RRC_CONNECTED RRC connection release by normal operation RRCConnectionRelease
1
ConnRelease_CpCcNormal
Figure 65. Collection Time for ConnRelease_CpCcTo eNB UE
MAC/RLC/ PDCP/GTP
ECCB
MME
S/GW
RRC_CONNECTED Success Message
X
RRC connection release by internal message timeout RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_CpCcTo
112
Chapter 2 Counter Description Figure 66. Collection Time for ConnRelease_CpCcFail (1) UE
eNB
MME
S/GW
RRC_CONNECTED ECMB reset RRCConnectionRelease
1
Failure - ConnRelease_CpCcFail
Figure 67. Collection Time for ConnRelease_CpCcFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED Cell disabled RRCConnectionRelease
1
Failure - ConnRelease_CpCcFail
Figure 68. Collection Time for ConnRelease_CpCcFail (3) UE
eNB
MME
S/GW
RRC_CONNECTED Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_CpCcFail
113
Chapter 2 Counter Description Figure 69. Collection Time for ConnRelease_CpCcFail (4) UE
eNB
MME
S/GW
RRC_CONNECTED Internal resource allocation Failure RRCConnectionRelease
1
Failure - ConnRelease_CpCcFail
Figure 70. Collection Time for ConnRelease_UpGtpFail eNB ECCB
GTP
UE
MME
S/GW
RRC_CONNECTED Fail Message RRCConnectionRelease
1
Failure - ConnRelease_UpGtpFail
Figure 71. Collection Time for ConnRelease_UpMacFail (1) eNB UE
MAC
ECCB
MME
S/GW
RRC_CONNECTED Fail Message RRCConnectionRelease 1
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - ConnRelease_UpMacFail
114
Chapter 2 Counter Description
Figure 72. Collection Time for ConnRelease_UpMacFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED A mismatch of UE information occurred in the execution of audit between the ECCB and MAC 1
RRCConnectionRelease
Failure - ConnRelease_UpMacFail
Figure 73. Collection Time for ConnRelease_UpMacUEInact
UE
eNB
MME
S/GW
RRC_CONNECTED RRC connection release by Inactivity Timeout RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1 Failure - ConnRelease_UpMacUEInact
115
Chapter 2 Counter Description Figure 74. Collection Time for ConnRelease_UpPdcpFail eNB ECCB
PDCP
UE
MME
S/GW
RRC_CONNECTED Fail Message RRCConnectionRelease
1
Failure - ConnRelease_UpPdcpFail
Figure 75. Collection Time for ConnRelease_UpRlcFail (1) eNB UE
ECCB
RLC
MME
S/GW
RRC_CONNECTED Fail Message RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_UpRlcFail
116
Chapter 2 Counter Description
Figure 76. Collection Time for ConnRelease_UpRlcFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED A mismatch of UE information occurred in the execution of audit between the ECCB and RLC RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_UpRlcFail
117
Chapter 2 Counter Description Figure 77. Collection Time for ConnRelease_RrcHcTo UE
eNB
MME
S/GW
RRC_CONNECTED MeasurementReport HO Decision (Intra-eNB Handover) Target Cell Handover Preparation RRCConnectionReconfiguration RRCConnectionReconfigurationComplete
Timer IntraEnbHoComplete
X RRCConnectionRelease
1
Failure - ConnRelease_RrcHcTo
Figure 78. Collection Time for ConnRelease_RrcSigFail (1) UE
eNB
MME
S/GW
RRC connection establishement Procedure is completed but Attach Procedure is not completed RRCConnectionReestablishmentRequest RRCConnectionReestablishmentReject RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_RrcSigFail
118
Chapter 2 Counter Description Figure 79. Collection Time for ConnRelease_RrcSigFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionRequest (with S-TMSI) The call that have same S-TMSI exists already. so Delete the existing call RRCConnectionRelease
1
Failure - ConnRelease_RrcSigFail
Figure 80. Collection Time for ConnRelease_RrcSigFail (3) UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionRequest (with random value) The call that have same random value exists already. so Delete the existing call RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_RrcSigFail
119
Chapter 2 Counter Description Figure 81. Collection Time for ConnRelease_RrcSigTo UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReconfiguration Case 1. RRCConnectionReconfigurationComplete
Timer RRCConnectionReconfig
X
RRCConnectionRelease
1
Failure - ConnRelease_RrcSigTo
RRCConnectionReestablishmentRequest RRCConnectionReestablishment Case 2.
RRCConnectionReestablishmentComplete
Timer RRCConnectionReEstablish
X
RRCConnectionRelease
1
Failure - ConnRelease_RrcSigTo
1
Failure - ConnRelease_RrcSigTo
SecurityModeCommand Case 3.
SecurityModeFailure RRCConnectionRelease
SecurityModeCommand Timer RRCSecurityModeCommand
SecurityModeComplete
X
Case 4.
RRCConnectionRelease
1
Failure - ConnRelease_RrcSigTo
UECapabilityEnquiry Case 5.
Timer RRCUeCapabilityEnquiry
UECapabilityInformation
X RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_RrcSigTo
120
Chapter 2 Counter Description
Figure 82. Collection Time for ConnRelease_CpBhCacFail UE
eNB
MME
S/GW
RRC_CONNECTED CAC based on backhaul bandwidth Fail RRCConnectionRelease
1
Failure - ConnRelease_CpBhCacFail
Figure 83. Collection Time for ConnRelease_CpCapaCacFail UE
eNB
MME
S/GW
RRC_CONNECTED CAC based on Call Count per eNB Fail or CAC based on Call Count per Cell Fail RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_CpCapaCacFail
121
Chapter 2 Counter Description
Figure 84. Collection Time for ConnRelease_CpQosCacFail UE
eNB
MME
S/GW
RRC_CONNECTED
CAC based on QoS Fail
RRCConnectionRelease
1
Failure - ConnRelease_CpBhCacFail
Figure 85. Collection Time for ConnRelease_S1apCuFail UE
eNB
MME
S/GW
RRC_CONNECTED S1AP Message RRC connection release by S1AP message RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apCuFail
122
Chapter 2 Counter Description Figure 86. Collection Time for ConnRelease_S1apLinkFail (1) UE
eNB
MME
S/GW
RRC_CONNECTED S1AP Message RRC connection release by S1AP message RRCConnectionRelease
1
Failure - ConnRelease_S1apCuFail
Figure 87. Collection Time for ConnRelease_S1apLinkFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED
SCTB reset
RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apLinkFail
123
Chapter 2 Counter Description Figure 88. Collection Time for ConnRelease_S1apRoTo (1) UE
Source eNB
MME
S/GW
RRC_CONNECTED MeasurementReport HO Decision (Intra LTE Handover) HANDOVER REQUIRED HANDOVER COMMAND RRCConnectionReconfiguration Timer S1RelocOverall UE CONTEXT RELEASE COMMAND
X RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apRoTo
124
Chapter 2 Counter Description Figure 89. Collection Time for ConnRelease_S1apRoTo (2) UE
Source eNB
MME
S/GW
RRC_CONNECTED MeasurementReport HO Decision (Inter-RAT Handover: UTRAN, GERAN) HANDOVER REQUIRED HANDOVER COMMAND MobilityFromEUTRACommand Timer S1RelocOverall UE CONTEXT RELEASE COMMAND
X RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apRoTo
125
Chapter 2 Counter Description Figure 90. Collection Time for ConnRelease_S1apRoTo (3) UE
Source eNB
MME
S/GW
RRC_CONNECTED HRPD Pre-Registration MeasurementReport HO Decision (Inter-RAT Handover: CDMA2000 HRPD ) HandoverFromEUTRAPreparationRequest ULHandoverPreparationTransfer UPLINK S1 CDMA2000 TUNNELING DOWNLINK S1 CDMA2000 TUNNELING MobilityFromEUTRACommand Timer S1RelocOverall UE CONTEXT RELEASE COMMAND
X RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apRoTo
126
Chapter 2 Counter Description Figure 91. Collection Time for ConnRelease_S1apSigFail (1) UE
eNB
MME
S/GW
RRC_CONNECTED
UE CONTEXT RELEASE COMMAND RRCConnectionRelease
1
Failure - ConnRelease_S1apSigFail
Figure 92. Collection Time for ConnRelease_S1apSigFail (2) UE
eNB
MME
S/GW
RRC_CONNECTED RESET
RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apSigFail
127
Chapter 2 Counter Description Figure 93. Collection Time for ConnRelease_S1apSigFail (3) UE
eNB
MME
S/GW
RRC_CONNECTED INITIAL CONTEXT SETUP REQUEST (with UE Radio Capability and UE Security Capabilities) Integrity algorithm of UE is eia0 but Cipering algorithm of UE is not eea0 RRCConnectionRelease
1
Failure - ConnRelease_S1apSigFail
UE CONTEXT MODIFICATION REQUEST(with UE Security Capabilities) Integrity algorithm of UE is eia0 but Cipering algorithm of UE is not eea0 RRCConnectionRelease
1
Failure - ConnRelease_S1apSigFail
UECapabilityInformation Integrity algorithm of UE is eia0 but Cipering algorithm of UE is not eea0 RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_S1apSigFail
128
Chapter 2 Counter Description Figure 94. Collection Time for ConnRelease_S1apSigTo UE
eNB
MME
S/GW
RRC_CONNECTED INITIAL CONTEXT SETUP REQUEST
Timer S1InitialContextSetup INITIAL CONTEXT SETUP RESPONSE
X RRCConnectionRelease
1
Failure - ConnRelease_RrcSigTo
Figure 95. Collection Time for ConnRelease_X2apCuFail UE
Source eNB
Target eNB
RRC_CONNECTED X2AP Message RRC connection release by X2AP message RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_X2apCuFail
129
Chapter 2 Counter Description Figure 96. Collection Time for ConnRelease_X2apRoTo UE
Source eNB
Target eNB
RRC_CONNECTED MeasurementReport HO Decision (Inter X2 Handover) HANDOVER REQUEST
HANDOVER REQUEST ACKNOWLEDGE RRCConnectionReconfiguration Timer X2RelocOverall UE CONTEXT RELEASE
X RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_X2apRoTo
130
Chapter 2 Counter Description Figure 97. Collection Time for ConnRelease_X2apSigFail (1) UE
Source eNB
Target eNB
RRC_CONNECTED MeasurementReport HO Decision (Inter X2 Handover) HANDOVER REQUEST
HANDOVER REQUEST ACKNOWLEDGE RRCConnectionReconfiguration RESET REQUEST
RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Failure - ConnRelease_X2apSigFail
131
Chapter 2 Counter Description Figure 98. Collection Time for ConnRelease_X2apSigFail (2) Source eNB UE
ECCB
CSAB
Target eNB
RRC_CONNECTED MeasurementReport HO Decision (Inter X2 Handover) HANDOVER REQUEST
HANDOVER REQUEST ACKNOWLEDGE RRCConnectionReconfiguration X2ResetRequest RRCConnectionRelease
1
Failure - ConnRelease_X2apSigFail
Call statistics are released when RRC connection is released. Since RRC connection release cause is returned, it is possible to determine call release cause.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
132
Chapter 2 Counter Description
RRC Connection Number This section provides statistics on the average RRC connection count per unit time and the maximum RRC connection count for each cell. The RRC connection count is collected every 2 seconds, and the statistics block calculates the average, maximum and total values per minute using the collected data. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnNoAvg
count
The average number of RRC connection per unit time
This counter is calculated when measurement period comes
Y
GAUGE
2s
float
0~3.4*10^3 8
ConnNoTot /ConnNoC nt
sum(ConnNoTot )/sum(ConnNoC nt)
ConnNoMax
count
The average number of ConnNoAvg
This counter is updated when ConnNoAvg is collected and it it greater than previous value
Y
GAUGE
2s
float
0~3.4*10^3 8
-
max(ConnNoMa x)
ConnNoTot
count
The maximum number of ConnNoAvg
This counter is cumulated when ConnNoAvg is collected
Y
GAUGE
2s
float
0~3.4*10^3 8
-
-
ConnNoCnt
count
The cumulated collection count of ConnNoAvg
This counter is cumulated by 1 when ConnNoAvg is
-
GAUGE
2s
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
133
Chapter 2 Counter Description Name
Unit
Description
ReleaseCall HoldingTime Avg
s
The average number of RRC connection holding time
ReleaseCall HoldingTime Tot
s
ReleaseCall HoldingTime Cnt
count
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is calculated when measurement period comes
Y
SI
event
float
0~3.4*10^3 8
ReleaseCal lHoldingTi meTot/Rele aseCallHol dingTimeC nt
sum(ReleaseCal lHoldingTimeTot )/sum(ReleaseC allHoldingTimeC nt)
The cumulated number of ReleaseCallHoldingTim eAvg
This counter is cumulated when ReleaseCallHoldingTim eAvg is collected
Y
SI
event
float
0~3.4*10^3 8
-
-
The cumulated collection count of ReleaseCallHoldingTim eAvg
This counter is cumulated by 1 when ReleaseCallHoldingTim eAvg is collected
Y
SI
event
int
0~2147483 647
-
-
collected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
134
Chapter 2 Counter Description
Collection Time Figure 99. Collection Time for RRC Connection Number UE
Target eNB RRCConnectionRequest
Case 1.
Case 2.
RRCConnectionSetup
1
1
Source eNB
MME
S/GW
ConnNoAvg ConnNoMax ConnNoTot ConnNoCnt
HANDOVER REQUEST ConnNoAvg ConnNoMax HANDOVER REQUEST ACKNOWLEDGE ConnNoTot ConnNoCnt HANDOVER REQUEST
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
ConnNoAvg ConnNoMax ConnNoTot ConnNoCnt
HANDOVER REQUEST ACKNOWLEDGE
135
Chapter 2 Counter Description
Figure 100. Collection Time for Release Call Holding Time UE
Target eNB
Source eNB
MME
S/GW
RRCConnectionRequest RRCConnectionSetup RRCConnectionSetupComplete • • •
1
RRCConnectionRelease
ReleaseCallHoldingTimeAvg ReleaseCallHoldingTimeTot ReleaseCallHoldingTimeCnt
X2 Handover Success • • •
1
RRCConnectionRelease
ReleaseCallHoldingTimeAvg ReleaseCallHoldingTimeTot ReleaseCallHoldingTimeCnt
S1 Handover Success • • •
1
RRCConnectionRelease
ReleaseCallHoldingTimeAvg ReleaseCallHoldingTimeTot ReleaseCallHoldingTimeCnt
Inter-RAT Handover Success • • •
RRCConnectionRelease
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
ReleaseCallHoldingTimeAvg ReleaseCallHoldingTimeTot ReleaseCallHoldingTimeCnt
136
Chapter 2 Counter Description
RRC Connection Number per PLMN This section provides statistics on the RRC connection count per PLMN and cell. Collects the statistics data for the average RRC connection count and the maximum RRC connection count for each PLMN and cell. Index Name
Description
PLMN
PLMN Id, the first three digits are MCC and the others are MNC
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PLMNCon nNoAvg
count
The average number of RRC connection per PLMN
This counter is calculated when measurement period comes
Y
GAUGE
2s
float
0~3.4*10 ^38
PLMNCon nNoTot/PL MNConnN oCnt
sum(PLMNConn NoTot)/sum(PLM NConnNoCnt)
PLMNCon nNoMax
count
The maximum number of PLMNConnNoAvg
This counter is updated when PLMNConnNoAvg is collected and it is greater than previous value
Y
GAUGE
2s
float
0~3.4*10 ^38
-
max(PLMNConn NoMax)
PLMNCon nNoTot
count
The cumulated number of PLMNConnNoAvg
This counter is cumulated when PLMNConnNoAvg is collected
Y
GAUGE
2s
float
0~3.4*10 ^38
-
-
PLMNCon nNoCnt
count
The cumulated collection count of PLMNConnNoAvg
This counter is cumulated by 1 when PLMNConnNoAvg is collected
Y
GAUGE
2s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
137
Chapter 2 Counter Description
Collection Time Figure 101. Collection Time for RRC Connection Number per PLMN UE
Target eNB
Source eNB
MME
S/GW
RRCConnectionRequest RRCConnectionSetup
Case 1.
RRCConnectionSetupComplete
1
PLMNConnNoAvg PLMNConnNoMax PLMNConnNoTot PLMNConnNoCnt
HANDOVER REQUEST Case 2. 1
PLMNConnNoAvg HANDOVER REQUEST ACKNOWLEDGE PLMNConnNoMax PLMNConnNoTot PLMNConnNoCnt
HANDOVER REQUEST Case 3. 1
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
PLMNConnNoAvg PLMNConnNoMax PLMNConnNoTot PLMNConnNoCnt
HANDOVER REQUEST ACKNOWLEDGE
138
Chapter 2 Counter Description
RRC Connection Setup Time This section provides statistics on the RRC connection count by PLMN and Cell. Collects the statistics data for the average RRC connection count and the maximum RRC connection count for each PLMN and cell. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause
RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: delay_tolerant_access: Access by the delay tolerant access
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstabTi meAvg
ms
The average RRC connection setup time during RRC connection establishment Procedure
This counter is calculated when measurement period comes
Y
GAUGE
event
float
0~3.4*10 ^38
ConnEstabTi meTot/Conn EstabTimeC nt
sum(ConnEstabTi meTot)/sum(Conn EstabTimeCnt)
ConnEstabTi meMax
ms
The maximum number of ConnEstabTimeAvg
This counter is updated when ConnEstabTimeA vg is collected and it is greater than previous value
Y
GAUGE
event
float
0~3.4*10 ^38
-
max(ConnEstabTi meMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
139
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnEstabTi meTot
ms
The cumulated number of ConnEstabTimeAvg
This counter is cumulated when ConnEstabTimeA vg is collected
Y
GAUGE
event
float
0~3.4*10 ^38
-
-
ConnEstabTi meCnt
cou nt
The cumulated collection count of ConnEstabTimeAvg
This counter is cumulated by 1 when ConnEstabTimeA vg is collected
-
GAUGE
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
140
Chapter 2 Counter Description
Collection Time Figure 102. Collection Time for RRC Connection Setup Time UE
eNB
MME
S/GW
RRC_IDLE RRCConnectionRequest
RRCConnectionSetup 1
ConnEstabTimeAvg ConnEstaabTimeMax ConnEstabTimeTot ConnEstabTimeCnt
RRCConnectionSetupComplete
The RRC Connection setup time is taken from receiving the RRC Connection Request message up to receiving the RRC Connection Setup Complete message. The eNB calculates and reports to the LSM the average and maximum values for the collection period (in milliseconds).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
141
Chapter 2 Counter Description
RRC Connection Re-establishment Time This section provides statistics on the average and maximum RRC Connection Reestablishment Setup times. The cause is identified by the RRC connection Reestablishment cause informed by the UE. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
ReEstabCause
RRC Connection Reestablishment Cause 0: reconfigurationFailure: Reestablishment occurs due to reconfiguration failure 1: handoverFailure: Reestablishment occurs due to handover failure 2: otherFailure: Reestablishment occurs due to other failures 3: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEsta bTimeAvg
ms
The average RRC connection setup time during RRC connection re-establishment Procedure
This counter is calculated when measurement period comes
Y
GAUGE
event
float
0~3.4*1 0^38
ConnReEst abTimeTot/ ConnReEst abTimeCnt
sum(ConnReEstab TimeTot)/sum(Con nReEstabTimeCnt)
ConnReEsta bTimeMax
ms
The maximum number of ConnReEstabTimeAvg
This counter is updated when ConnReEstabTim eAvg is collected and it is greater than previous
Y
GAUGE
event
float
0~60*Pe riod*100 0
-
max(ConnReEstab TimeMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
142
Chapter 2 Counter Description Name
Unit
Description
ConnReEsta bTimeTot
ms
The cumulated number of ConnReEstabTimeAvg
ConnReEsta bTimeCnt
count
The cumulated collection count of ConnReEstabTimeAvg
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when ConnReEstabTim eAvg is collected
Y
GAUGE
event
float
0~3.4*1 0^38
-
-
This counter is cumulated by 1 when ConnReEstabTim eAvg is collected
-
GAUGE
event
int
0~21474 83647
-
-
value
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
143
Chapter 2 Counter Description
Collection Time Figure 103. Collection Time for Re-establishment Time UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
RRCConnectionReestablishment
1
ConnReEstabTimeAvg ConnReEstaabTimeMax ConnReEstabTimeTot ConnReEstabTimeCnt
RRCConnectionReestablishmentComplete
RRC_CONNECTED
The RRC Connection setup time is a time taken from receiving the RRC Connection Request message up to receive in the RRC Connection Setup Complete message. The eNB calculates and reports to the LSM the average and maximum values for the collection period (in milliseconds).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
144
Chapter 2 Counter Description
Call Drop This section provides statistics on the Call Drop. Call drop statistics are calculated for successfully connected calls that abnormally dropped due to eNB failure or by the MME. It is identified by the RRC connection establishment cause informed by the UE. Successful call connection indicates that the default bearer setup is successful or incoming handover is successful for a call. However, calls released by the eNB due to user inactivity, normally released by the MME, and released by the UE duplication are not considered abnormally terminated. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
CallDropEstabCause
RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: delay_tolerant_access: Access by the delay tolerant access 6: relocated: Access by the UE due to handover
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDrop_EccbDs pAuditRlcMacCall Release
count
The cumulated number when a call is released since a mismatch occurs between the ECCB and
This counter is cumulated when a call is released since a mismatch occurs
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
145
Chapter 2 Counter Description Name
Unit
Description
Trigger
MAC/RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
between the ECCB and MAC/RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDrop_EccbRc vResetRequestFro mEcmb
count
The cumulated number when a call is released due to ECMB reset after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released due to ECMB reset after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDrop_EccbRc vCellReleaseIndFr omEcmb
count
The cumulated number when a call is released as a result of being notified by the ECMB that the operational state of the cell (operationalState of RTRV-CELL-STS) is changed to disabled after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released as a result of being notified by the ECMB that the operational state of the cell (operationalState of RTRV-CELL-STS) is changed to disabled after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDrop_EccbRa dioLinkFailure
count
The cumulated number when a call is released as a result of not receiving HARQ ACK notification from the UE although the
This counter is cumulated when a call is a released due to a timeout that occurs while waiting to
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
146
Chapter 2 Counter Description Name
Unit
Description
Trigger
MAC transmitted messages to the UE equal to max retransmission after an INITIAL UE message about the UE which is transmitted to MME.
receive RRCConnectionReestablishment when the initial UE message is transmitted to the UE and the MAC transmits messages to the UE as many times as the max retransmission, but HARQ ACK notification is not received from the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDrop_EccbDs pAuditMacCallRel ease
count
The cumulated number when a call is released since a mismatch occurs between the ECCB and MAC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released since a mismatch occurs between the ECCB and MAC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDrop_EccbArq MaxReTransmissi on
count
The cumulated number when a call is released as a result of not receiving ARQ ACK notification from the UE although the RLC transmitted messages to the UE equal to max retransmission after an INITIAL UE
This counter is cumulated when a call is released as a result of not receiving ARQ ACK notification from the UE although the RLC transmitted messages to the UE equal to max
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
147
Chapter 2 Counter Description Name
Unit
Description
Trigger
message about the UE which is transmitted to MME.
retransmission after an INITIAL UE message about the UE which is transmitted to MME.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDrop_EccbDs pAuditRlcCallRele ase
count
The cumulated number when a call is released since a mismatch occurs between the ECCB and RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released since a mismatch occurs between the ECCB and RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDrop_EccbTm outRrcConnection Reconfig
count
The cumulated number when a call is released due to a timeout that has occurred since RRCConnectionReconfigu rationComplete is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released due to a timeout that has occurred since RRCConnectionReco nfigurationComplete is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDrop_EccbTm outRrcConnection Reestablish
count
The cumulated number when a call is released due to a timeout that has occurred since RRCConnectionRe-
This counter is cumulated when a call is released due to a timeout that has occurred since
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
148
Chapter 2 Counter Description Name
CallDrop_EccbS1 SctpOutOfService
Unit
count
Description
Trigger
establishmentComplete is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
RRCConnectionReestablishmentComplet e is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
The cumulated number of failures to perform the RRC connection reestablishment procedure due to a change of S1AP link status to 'Out of Service' after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when the eNB releases the call because the status of the callrelated S1AP link has been changed to OOS (Out Of Service) after transmitting Initial UE message to MME This counter is cumulated when the eNB releases a call due to an SCTB reset after transmitting the Initial UE message to MME.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
149
Chapter 2 Counter Description
Collection Time Figure 104. Collection Time for CallDrop_EccbDspAuditRlcMacCallRelease UE
eNB
MME
S/GW
RRC_CONNECTED
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC 1
CallDrop_EccbDspAuditRlcMacCallRelease
RRC_IDLE
Figure 105. Collection Time for CallDrop_EccbRcvResetRequestFromEcmb UE
eNB
MME
S/GW
RRC_CONNECTED ECMB reset 1
CallDrop_EccbRcvResetRequestFromEcmb
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
150
Chapter 2 Counter Description Figure 106. Collection Time for CallDrop_EccbRcvCellReleaseIndFromEcmb UE
eNB
MME
S/GW
RRC_CONNECTED
Cell disabled 1
CallDrop_EccbRcvResetRequestFromEcmb
RRC_IDLE
Figure 107. Collection Time for CallDrop_EccbRadioLinkFailure eNB ECCB
MAC
UE
MME
S/GW
RRC_CONNECTED HARQ ACK
X
Fail Message
RRCConnectionReestablishmentRequest
X
Timer InternalReestablishmentTimeToWait 1
CallDrop_EccbRadioLinkFailure
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
151
Chapter 2 Counter Description Figure 108. Collection Time for CallDrop_EccbDspAuditMacCallRelease UE
eNB
MME
S/GW
RRC_CONNECTED A mismatch of UE information occurred in the execution of audit between the ECCB and MAC 1
CallDrop_EccbDspAuditMacCallRelease
RRC_IDLE
Figure 109. Collection Time for CallDrop_EccbArqMaxReTransmission eNB ECCB
RLC
UE
MME
S/GW
RRC_CONNECTED ARQ ACK
X
Fail Message
RRCConnectionReestablishmentRequest
X
Timer InternalReestablishmentTimeToWait 1
CallDrop_EccbArqMaxReTransmission
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
152
Chapter 2 Counter Description Figure 110. Collection Time for CallDrop_EccbDspAuditRlcCallRelease UE
eNB
MME
S/GW
RRC_CONNECTED A mismatch of UE information occurred in the execution of audit between the ECCB and RLC 1
CallDrop_EccbDspAuditRlcCallRelease
RRC_IDLE
Figure 111. Collection Time for CallDrop_EccbTmoutRrcConnectionReconfig UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReconfiguration Timer RRCConnectionReconfiguration RRCConnectionReconfigurationComplete
X
1
CallDrop_EccbTmoutRrcConnectionReconfig
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
153
Chapter 2 Counter Description Figure 112. Collection Time for CallDrop_EccbTmoutRrcConnectionReestablish UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
RRCConnectionReestablishment Timer RRCConnectionReEstablish RRCConnectionReestablishmentComplete
X
1
CallDrop_EccbTmoutRrcConnectionReestablish
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
154
Chapter 2 Counter Description Figure 113. Collection Time for CallDrop_EccbS1SctpOutOfService (1) UE
eNB
MME
S/GW
RRC_CONNECTED
S1 AP Link is Out of Service Status
X 1
CallDrop_EccbS1SctpOutOfService
RRC_IDLE
Figure 114. Collection Time for CallDrop_EccbS1SctpOutOfService (2) UE
eNB
MME
S/GW
RRC_CONNECTED SCTB reset 1
CallDrop_EccbS1SctpOutOfService
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
155
Chapter 2 Counter Description
Call Drop per QCI This section provides statistics on the Call Drop per QCI. When the calls that are connected successfully but abnormally dropped due to eNB (MME) failure, they are counted per QCI for E-RAB. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDropQci_Eccb DspAuditRlcMacCa llRelease
count
The cumulated number when a call is released since a mismatch occurs between the ECCB and MAC/RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released since a mismatch occurs between the ECCB and MAC/RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDropQci_Eccb RcvResetRequestF romEcmb
count
The cumulated number when a call is released due to ECMB reset after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released due to ECMB reset after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
156
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDropQci_Eccb RcvCellReleaseInd FromEcmb
count
The cumulated number when a call is released as a result of being notified by the ECMB that the operational state of the cell (operationalState of RTRVCELL-STS) is changed to disabled after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released as a result of being notified by the ECMB that the operational state of the cell (operationalState of RTRV-CELL-STS) is changed to disabled after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDropQci_Eccb RadioLinkFailure
count
The cumulated number when a call is released as a result of not receiving HARQ ACK notification from the UE although the MAC transmitted messages to the UE equal to max retransmission after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released as a result of not receiving HARQ ACK notification from the UE although the MAC transmitted messages to the UE equal to max retransmission after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDropQci_Eccb DspAuditMacCallR elease
count
The cumulated number when a call is released since a mismatch occurs between the ECCB and MAC while performing an audit of the UE information after an INITIAL UE
This counter is cumulated when a call is released since a mismatch occurs between the ECCB and MAC while
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
157
Chapter 2 Counter Description Name
Unit
Description
Trigger
message about the UE which is transmitted to MME.
performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
CallDropQci_Eccb ArqMaxReTransmi ssion
count
The cumulated number when a call is released as a result of not receiving ARQ ACK notification from the UE although the RLC transmitted messages to the UE equal to max retransmission after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released as a result of not receiving ARQ ACK notification from the UE although the RLC transmitted messages to the UE equal to max retransmission after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDropQci_Eccb DspAuditRlcCallRel ease
count
The cumulated number when a call is released since a mismatch occurs between the ECCB and RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated a call is released since a mismatch occurs between the ECCB and RLC while performing an audit of the UE information after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDropQci_Eccb TmoutRrcConnecti
count
The cumulated number when a call is released due to a timeout
This counter is cumulated when a call
Y
CC
event
int
0~21 4748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
158
Chapter 2 Counter Description Name
Unit
onReconfig
Description
Trigger
that has occurred since RRCConnectionReconfiguratio nComplete is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
is released due to a timeout that has occurred since RRCConnectionReco nfigurationComplete is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 3647
Granularity Formula
Hourly, Daily, Monthly Formula
CallDropQci_Eccb TmoutRrcConnecti onReestablish
count
The cumulated number when a call is released due to a timeout that has occurred since RRCConnectionReestablishmentComplete is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when a call is released due to a timeout that has occurred since RRCConnectionReestablishmentComplet e is not received from the UE after an INITIAL UE message about the UE which is transmitted to MME.
Y
CC
event
int
0~21 4748 3647
-
-
CallDropQci_Eccb S1SctpOutOfServic e
count
The cumulated number of failures to perform the RRC connection reestablishment procedure due to a change of S1AP link status to 'Out of Service' after an INITIAL UE message about the UE which is transmitted to MME.
This counter is cumulated when the eNB releases the call because the status of the callrelated S1AP link has been changed to OOS (Out Of Service) after transmitting Initial UE message to MME.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
159
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
This counter is cumulated when the eNB releases a call due to an SCTB reset after transmitting the Initial UE message to MME. ErabIncomingHoSu ccNbr
count
The cumulated number when handover from the target eNB is completed normally.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the Handover is completed in the Target eNB
160
Chapter 2 Counter Description
Collection Time Figure 115. Collection Time for CallDropQci_EccbDspAuditRlcMacCallRelease UE
eNB
MME
S/GW
RRC_CONNECTED
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC 1
CallDropQci_EccbDspAuditRlcMacCallRelease
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
161
Chapter 2 Counter Description Figure 116. Collection Time for CallDropQci_EccbRcvResetRequestFromEcmb UE
eNB
MME
S/GW
RRC_CONNECTED
ECMB reset 1
CallDropQci_EccbRcvResetRequestFromEcmb
RRC_IDLE
Figure 117. Collection Time for CallDropQci_EccbRcvCellReleaseIndFromEcmb UE
eNB
MME
S/GW
RRC_CONNECTED
Cell disabled 1
CallDropQci_EccbRcvCellReleaseIndFromEcmb
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
162
Chapter 2 Counter Description Figure 118. Collection Time for CallDropQci_EccbRadioLinkFailure eNB ECCB
MAC
UE
MME
S/GW
RRC_CONNECTED HARQ ACK
X
Fail Message
RRCConnectionReestablishmentRequest
X
Timer InternalReestablishmentTimeToWait 1
CallDropQci_EccbRadioLinkFailure
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
163
Chapter 2 Counter Description Figure 119. Collection Time for CallDropQci_EccbDspAuditMacCallRelease UE
eNB
MME
S/GW
RRC_CONNECTED
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC 1
CallDropQci_EccbDspAuditMacCallRelease
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
164
Chapter 2 Counter Description Figure 120. Collection Time for CallDropQci_EccbArqMaxReTransmission eNB ECCB
RLC
UE
MME
S/GW
RRC_CONNECTED ARQ ACK
X
Fail Message
RRCConnectionReestablishmentRequest
X
Timer InternalReestablishmentTimeToWait 1
CallDropQci_EccbArqMaxReTransmission
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
165
Chapter 2 Counter Description Figure 121. Collection Time for CallDropQci_EccbDspAuditRlcCallRelease UE
eNB
MME
S/GW
RRC_CONNECTED
A mismatch of UE information occurred in the execution of audit between the ECCB and RLC 1
CallDropQci_EccbDspAuditRlcCallRelease
RRC_IDLE
Figure 122. Collection Time for CallDropQci_EccbTmoutRrcConnectionReconfig UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReconfiguration Timer RRCConnectionReconfiguration RRCConnectionReconfigurationComplete
X
1
CallDropQci_EccbTmoutRrcConnectionReconfig
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
166
Chapter 2 Counter Description Figure 123. Collection Time for CallDropQci_EccbTmoutRrcConnectionReestablish UE
eNB
MME
S/GW
RRC_CONNECTED RRCConnectionReestablishmentRequest
RRCConnectionReestablishment Timer RRCConnectionReEstablish RRCConnectionReestablishmentComplete
X
1
CallDropQci_EccbTmoutRrcConnectionReestablish
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
167
Chapter 2 Counter Description Figure 124. Collection Time for CallDropQci_EccbS1SctpOutOfService (1) UE
eNB
MME
S/GW
RRC_CONNECTED
S1 AP Link is Out of Service Status
X 1
CallDropQci_EccbS1SctpOutOfService
RRC_IDLE
Figure 125. Collection Time for CallDropQci_EccbS1SctpOutOfService (2) UE
eNB
MME
S/GW
RRC_CONNECTED
SCTB reset 1
CallDropQci_EccbS1SctpOutOfService
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
168
Chapter 2 Counter Description Figure 126. Collection Time for ErabIncomingHoSuccNbr (1) Source eNB
UE
Target eNB
MME
S/GW
UE moves to Inter eNB Cell MeasurementReport HANDOVER REQUEST
HANDOVER REQUEST ACKNOWLEDGE RRCConnectionReconfiguration SN STATUS TRANSFER
RRCConnectionReconfigurationComplete PATH SWITCH REQUEST
PATH SWITCH REQUEST ACKNOWLEDGE UE CONTEXT RELEASE
Handover Success 1
ErabIncomingHoSuccNbr
RRC_CONNECTED
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
169
Chapter 2 Counter Description
Figure 127. Collection Time for ErabIncomingHoSuccNbr (2) UE
Target eNB
MME
S/GW
Intra LTE S1 Handover or Inter-RAT Handover HANDOVER REQUEST
HANDOVER REQUEST ACKNOWLEDGE MME STATUS TRANSFER RRCConnectionReconfigurationComplete HANDOVER NOTIFY
Handover Success 1
ErabIncomingHoSuccNbr
RRC_CONNECTED
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
170
Chapter 2 Counter Description
RRC Connection Release per QCI This section provides statistics on the RRC Connection Release for each cell and QCI. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
RRC_QCI_SPECIFIC
enum = NO_QCI(0), QCI_1(1), QCI_5(2), QCI_8(3), QCI_9(4)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease_CpC cNormal_QCI
count
The cumulated number when the RRC connection is released normally from the eNB after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released normally from the eNB after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_CpC cTo_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, GTP,
This counter is cumulated when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, GTP, RLC,
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
171
Chapter 2 Counter Description Name
ConnRelease_CpC cFail_QCI
Unit
count
Description
Trigger
RLC, MAC) after the RRC connection establishment procedure is completed.
MAC) after the RRC connection establishment procedure is completed.
The cumulated number when the RRC connection is released from the eNB since the eNB status changes or the eNB internal resource allocation fails after the RRC connection establishment procedure is completed.
This counter is cumulated when the eNB releases a call due to ECMB reset after RRC connection establishment Procedure completed This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled after completing RRC connection establishment Procedure This counter is cumulated when the eNB releases a call since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
172
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UE information after the RRC connection establishment procedure is completed. This counter is cumulated when the eNB releases a call since a failure occurs during internal resource allocation in eNB after the RRC connection establishment procedure is completed. ConnRelease_UpG tpFail_QCI
count
The cumulated number when the RRC connection is released from the eNB since a failure occurs between the GTP and ECCB after the RRC connection establishment procedure is completed.
This counter is cumulated when eNB released RRC Connection due to receiving Fail message from the GTP, after completing RRC connection establishment Procedure
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_UpM acFail_QCI
count
The cumulated number when the RRC connection is released from the eNB since a failure occurs between the MAC and ECCB after the RRC connection
This counter is cumulated when RRC Connection released due to receiving the Fail message from MAC after completing RRC connection establishment
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
173
Chapter 2 Counter Description Name
Unit
Description
Trigger
establishment procedure is completed.
Procedure This counter is cumulated when the RRC connection is released since a mismatch on the UE occurs between the ECCB and MAC when the eNB executes an audit of the UE information after the RRC connection establishment procedure is completed.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease_UpM acUEInact_QCI
count
The cumulated number when the RRC connection is released from the eNB since a timeout occurs in the UE after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC Connection released due to Inactivity Timeout occurs for UE after completed RRC connection establishment Procedure
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_UpP dcpFail_QCI
count
The cumulated number when the RRC connection is released from the eNB since a fail message is received from the PDCP after the RRC connection establishment procedure is completed.
This counter is cumulated when a call is release due to receiving Fail message from the PCDP after completing RRC connection establishment Procedure
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
174
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease_UpR lcFail_QCI
count
The cumulated number when the RRC connection is released from the eNB since a failure occurs between the RLC and ECCB after the RRC connection establishment procedure is completed.
This counter is cumulated when RRC Connection released due to receiving the Fail message from MAC after completing RRC connection establishment Procedure This counter is cumulated when the RRC connection is released since a mismatch on the UE occurs between the ECCB and RLC when the eNB executes an audit of the UE information after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_Rrc HcTo_QCI
count
The cumulated number when the RRC connection is released since RRCConnectionReconfi gurationComplete is not received from the UE during the intra-eNB handover procedure after the RRC connection
This counter is cumulated when the RRC connection is released since RRCConnectionReconfi gurationComplete is not received from the UE during the intra-eNB handover procedure after the RRC connection
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
175
Chapter 2 Counter Description Name
ConnRelease_Rrc SigFail_QCI
Unit
count
Description
Trigger
establishment procedure is completed.
establishment procedure is completed.
The cumulated number when the RRC connection is released from the eNB due to a duplication check after an RRCConnectionReestablishmentRequest or RRCConnectionReques t is received before the attach process is completed after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released in eNB since the RRC connection re-establishment procedure is judged unable to be performed when the eNB receives RRCConnectionReestablishmentRequest before transmitting INITIAL CONTEXT SETUP RESPONSE to MME since the attach process for the UE is not completed. This counter is cumulated when the RRC connection of an existing call is released in eNB through a duplication check when the eNB receives RRCConnectionReque st and the UE-Identity of RRCConnectionReque st is S-TMSI while an existing call has the
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
176
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
same S-TMSI. This counter is cumulated when the RRC connection of an existing call is released in eNB through a duplication check when the eNB receives RRCConnectionReque st and the UE-Identity of RRCConnectionReque st is a random value while an existing call has the same random value. ConnRelease_Rrc SigTo_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive a RRC response message from the UE after the RRC connection establishment procedure is completed.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when RRCConnectionRecon figurationComplete is not received from the UE after the RRC connection establishment procedure is completed and RRCConnectionRecon figuration is transmitted to the UE.
177
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when RRCConnectionReestablishmentComplet e is not received from the UE after the RRC connection establishment procedure is completed and RRCConnectionReestablishment is transmitted to the UE. This counter is cumulated when the RRC connection is released in eNB after the UE establishment procedure is completed, SecurityModeComman d is transmitted to the UE, and SecurityModeFailure is received from the UE. This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
178
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
SecurityModeComplet e is not received from the UE after the RRC connection establishment procedure is completed and SecurityModeComman d is transmitted to the UE. This counter is cumulated when the RRC connection is released in eNB due to a timeout that occurs when UECapabilityInformati on is not received from the UE after the RRC connection establishment procedure is completed and UECapabilityEnquiry is transmitted to the UE. ConnRelease_CpB hCacFail_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on backhaul bandwidth operation in the RRC
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the RRC connection is released in eNB since Call Admission Control (CAC) based on the backhaul bandwidth operation fails in the ERAB setup or E-RAB
179
Chapter 2 Counter Description Name
Unit
Description
Trigger
connection establishment procedure after the said procedure is completed.
modify procedure after the RRC connection establishment procedure is completed.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease_CpC apaCacFail_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation in the RRC connection establishment procedure after the said procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation in the RRC connection establishment procedure after the said procedure is completed.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_CpQ osCacFail_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on QoS operation in the RRC connection establishment procedure after the said procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a failure of the Call Admission Control (CAC) based on QoS operation in the RRC connection establishment procedure after the said procedure is completed.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_S1a pCuFail_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a
This counter is cumulated when the RRC connection is released from the eNB
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
180
Chapter 2 Counter Description Name
Unit
Description
Trigger
S1AP message after the RRC connection establishment procedure is completed.
due to a S1AP message after the RRC connection establishment procedure is completed.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease_S1a pLinkFail_QCI
count
The cumulated number when the RRC connection is released from the eNB since the S1AP link status is changed to 'Out of Service' after the RRC connection establishment procedure is completed.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) after completing RRC connection establishment Procedure This counter is cumulated when RRC Connection is released due to SCTB reset after completing RRC connection establishment Procedure.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_S1a pRoTo_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred as a result of not being able to receive an UE CONTEXT RELEASE
This counter is cumulated when the RRC connection is released in the source eNB due to a timeout that occurs since the source eNB does not receive an UE CONTEXT RELEASE
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
181
Chapter 2 Counter Description Name
Unit
Description
Trigger
COMMAND message from MME after the source eNB receives a HANDOVER COMMAND from MME during intra LTE S1 handover or inter-RAT handover execution.
COMMAND message from MME after receiving HANDOVER COMMAND from MME while intra LTE S1 handover is performed. This counter is cumulated when the RRC connection is released in the source eNB due to a timeout that occurs since the source eNB does not receive an UE CONTEXT RELEASE COMMAND message from MME after receiving HANDOVER COMMAND from MME while inter-RAT (GERAN, UTRA) handover is performed. This counter is cumulated when the RRC connection is released in the source eNB due to a timeout that occurs since the source eNB does not receive an UE CONTEXT RELEASE COMMAND message from MME after
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
182
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
receiving S1AP DOWNLINK S1 CDMA2000 TUNNELING (with CDMA2000HO Status: HO Success) from MME while inter-RAT (CDMA2000 HRPD) handover is performed. ConnRelease_S1a pSigFail_QCI
count
The cumulated number when the RRC connection is released from the eNB since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME or a mismatch occurs between the integrity algorithm and ciphering algorithm of the UE after the RRC connection establishment procedure is completed.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when RRC Connection is released in eNB due to receiving the S1AP UE CONTEXT RELEASE COMMAND from MME after completing RRC connection establishment Procedure This counter is cumulated when RRC Connection is released in eNB due to receiving the S1AP RESET from MME after completing RRC connection establishment Procedure The counter is cumulated when the RRC connection is
183
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
released in eNB since the integrity algorithm of the UE is eia0 but the cipering algorithm is not eea0 when UE security capabilities are acquired after the RRC connection establishment procedure is completed. ConnRelease_S1a pSigTo_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a timeout that has occurred since an INITIAL CONTEXT SETUP RESPONSE message is not received from the UE after the RRC connection establishment procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a timeout that has occurred since an INITIAL CONTEXT SETUP RESPONSE message is not received from the UE after the RRC connection establishment procedure is completed.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_X2a pCuFail_QCI
count
The cumulated number when the RRC connection is released from the eNB due to a X2AP message in the RRC connection establishment procedure after the said procedure is completed.
This counter is cumulated when the RRC connection is released from the eNB due to a X2AP message in the RRC connection establishment procedure after the said procedure is completed.
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
184
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnRelease_X2a pLinkFail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_X2a pRoTo_QCI
count
The cumulated number when the RRC connection is released from the source eNB due to a timeout that has occurred since the source eNB is not able to receive an UE CONTEXT RELEASE message from the target eNB after receiving HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
This counter is cumulated when the RRC connection is released from the source eNB due to a timeout that has occurred since the source eNB is not able to receive an UE CONTEXT RELEASE message from the target eNB after receiving HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
Y
CC
event
int
0~2147 483647
-
-
ConnRelease_X2a pSigFail_QCI
count
The cumulated number when the RRC connection is released from the source eNB since a reset occurs in the X2 interface between the source eNB and target eNB after receiving a HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
This counter is cumulated when the RRC connection is released from the source eNB since a reset occurs in the X2 interface between the source eNB and target eNB after receiving a HANDOVER REQUEST ACKNOWLEDGE from the target eNB during inter X2 handover execution.
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
185
Chapter 2 Counter Description
RRC Connection Re-establishment per QCI This section provides statistics as shown below, when a RRC Reestablishment cause occurs with the UE in RRC connected state, statistics on the RRC connection Reestablishment are collected for each cell. (3GPP TS 36.331). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
ReEstabCause
RRC Connection Reestablishment Cause 0 (reconfigurationFailure): Reestablishment occurs due to reconfiguration failure 1 (handoverFailure): Reestablishment occurs due to handover failure 2 (otherFailure): Reestablishment occurs due to other failures 3: reserved
RRC_QCI_SPECIFIC
enum = NO_QCI(0), QCI_1(1), QCI_5(2), QCI_8(3), QCI_9(4)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEstabAtt_Q CI
count
The cumulated number of RRCConnectionReestablishmentRequest messages received from the UE.
This counter is cumulated when the eNB receives an RRCConnectionReestablishmentRequest message from the UE.
Y
CC
event
int
0~2147 483647
-
-
ConnReEstabSucc _QCI
count
The cumulated number of RRCConnectionReestablishmentComplete messages received from the UE during the
This counter is cumulated when eNB receives RRCConnectionReestablishmentComplete message as a result of
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
186
Chapter 2 Counter Description Name
ConnReEstabFail_ CpCcFail_QCI
Unit
count
Description
Trigger
RRC connection reestablishment procedure.
transmitting RRCConnectionReestablishment request to the UE during the RRC connection reestablishment procedure.
The cumulated number when the RRC connection reestablishment procedure fails due to a change of eNB status or eNB internal resource allocation fails.
This counter is cumulated in the following cases. This counter is cumulated when the eNB releases a call due to ECMB reset after the eNB transmits an RRCConnectionReestablishment request to the UE during the RRC connection reestablishment procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB. The operational state of the cell (operational State of RTRV-CELL-STS) gets changed due to a disabilty of the eNB transmission. RRC connection is being reestablished to the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
187
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
This counter is cumulated when the eNB releases the call because mismatches on the UE have occurred both between the ECCB and RLC and between the ECCB and MAC in the execution of an audit on UE information after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases a call since a failure occurs during internal resource allocation in eNB for transmitting RRCConnectionReestablishment to the UE during the RRC connection reestablishment procedure. ConnReEstabFail_ UpMacFail_QCI
count
The cumulated number of failures to perform the RRC connection reestablishment procedure due to a failure that has
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB releases the call as a result of receiving a Fail message from the MAC after the eNB has
188
Chapter 2 Counter Description Name
Unit
Description
Trigger
occurred between the MAC and ECCB during the said procedure.
transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call when there is a mismatch between the ECCB and MAC in the execution of the audit of UE information after the eNB has transmitted an RRCConnectionReestablishment to the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEstabFail_ UpPdcpFail_QCI
count
The cumulated number of failures to perform the RRC connection reestablishment procedure due to a failure that has occurred between the PDCP and ECCB during the said procedure.
This counter is cumulated when the eNB releases the call as a result of receiving a internal failure message (msgCpdcpControlFailure) from the PDCP after the eNB has transmitted an RRCConnectionReestablishment to the UE. When receiving invalid parameter (in case when callid, rbid and lochType are not within the range) from ECCB block in eNB, PDCP transmits Failure Message to ECCB block.
Y
CC
event
int
0~2147 483647
-
-
ConnReEstabFail_
count
The cumulated number
This counter is
Y
CC
event
int
0~2147
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
189
Chapter 2 Counter Description Name UpRlcFail_QCI
Unit
Description
Trigger
of failures to perform the RRC connection reestablishment procedure due to a failure that has occurred between the RLC and ECCB during the said procedure.
cumulated when the eNB releases the call as a result of receiving a internal failure message (msgCrlcConfigFailure or msgCrlcControlFailure) from the RLC after the eNB has transmitted an RRCConnectionReestablishment to the UE. When invalid parameter (in case when callid, rbid, lochID and lochType are not within the range) is received from ECCB block in eNB or when there are not much resources in the RLC, the RLC transmits Failure Message to ECCB block. This counter is cumulated when the eNB releases the call because a mismatch with the RLC has occurred in the execution of an audit with the DSP after the eNB has transmitted an RRCConnectionReestablishment to the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
483647
190
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnReEstabFail_ RrcSigTo_QCI
count
The cumulated number of failures to perform the RRC connection reestablishment procedure due to a timeout that has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, RLC, MAC) or RRC connection reestablishment complete message from the UE during the said procedure.
This counter is cumulated when the eNB releases the call due to a timeout has occurred as a result of not being able to receive an RRCConnectionReestablishmentComplete message from the UE after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call due to a timeout has occurred as a result of not being able to receive a response message from the inner blocks (PDCP, RLC, MAC) after the eNB has transmitted an RRCConnectionReestablishment to the UE.
Y
CC
event
int
0~2147 483647
-
-
ConnReEstabFail_ S1apLinkFail_QCI
count
The cumulated number of failures to perform the RRC connection reestablishment procedure due to a
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
191
Chapter 2 Counter Description Name
ConnReEstabFail_ S1apLSigFail_QCI
Unit
count
Description
Trigger
change of S1AP link status to 'Out of Service' during the said procedure.
link has been changed to OOS (Out Of Service) after the eNB has transmitted an RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call due to an SCTB reset, occurred after the eNB has transmitted an RRCConnectionReestablishment request to the UE.
The cumulated number of failures to perform the RRC connection reestablishment procedure as a result of receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the said procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME after the eNB has transmitted RRCConnectionReestablishment to the UE. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME after the eNB
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
192
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
has transmitted an RRCConnectionReestablishment to the UE. ConnReEstabRejec t_CpCcFail_QCI
count
The cumulated number of RRCConnectionReestablishmentReject messages transmitted to the UE since the RRC connection reestablishment procedure has been judged unable to be performed after receiving RRCConnectionReestablishmentRequest from the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB transmits the RRCConnectionReestablishmentReject message to the UE of it being judged to be unable to perform RRC connection reestablishment Procedure due to the lack of context information about the UE even though the eNB has received an RRCConnectionReestablishmentRequest message from the UE. This counter is cumulated when the eNB transmits to RRC connection reestablishment rejects message to the UE because the RRC connection reestablishment procedure has been judged unable to perform. As a result of
193
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
which the eNB receives a RRC connection reestablishment request message before transmitting to MME a INITIAL CONTEXT SETUP RESPONSE message, which happens when the UE is not completely attached. This counter is cumulated when the eNB transmits an RRC connection reestablishment rejects message to the UE because the RRC connection reestablishment procedure has been judged unable to perform as a result of the eNB receiving a RRC connection reestablishment request message from the UE before receiving a SN STATUS TRANSFER from the source of eNB or receiving a MME STATUS TRANSFER message from MME during the inter-eNB handing over procedure. This counter is Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
194
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed because, even though the eNB has received from the UE an RRCConnectionReestablishmentRequest to a different cell from the existing cell, the new target cell is barred (cellBarred of RTRVCELL-ACS). This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed because, even though the eNB has received from the UE an RRCConnectionReSamsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
195
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
establishmentRequest to a different cell from the existing cell, the new target cell is in Locked or ShuttingDown status. This counter is cumulated when the eNB transmits the RRCConnectionReesta blishmentReject message to the UE of it being judged to be unable to perform RRC connection reestablishment Procedure due to failure of repremption procedure in the changed Cell even though the eNB has received an RRCConnectionReesta blishmentRequest message from the UE. ConnReEstabRejec t_CpCapaCaccFail _QCI
count
The cumulated number of RRCConnectionReestablishmentReject messages transmitted to the UE since the RRC connection reestablishment procedure has been judged unable to be
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be
196
Chapter 2 Counter Description Name
ConnReEstabRejec t_CpQosCacFail_Q CI
Unit
count
Description
Trigger
performed by the Call Admission Control (CAC) based on call count per cell operation or the CAC based on DRB count per cell operation after receiving RRCConnectionReestablishmentRequest from the UE.
performed by the Call Admission Control (CAC) based on call count per cell operation or the CAC based on DRB count per cell operation which in the new target cell; even though the eNB has received from the UE an RRCConnectionReestablishmentRequest, the target cell has changed from the existing cell to a new cell.
The cumulated number RRCConnectionReestablishmentReject messages transmitted to the UE since the RRC connection reestablishment procedure has been judged unable to be performed by the Call Admission Control (CAC) based on QoS operation after receiving RRCConnectionReestablishmentRequest from the UE.
This counter is cumulated when the eNB transmits an RRCConnectionReestablishmentReject message to the UE after the RRC connection reestablishment procedure has been judged unable to be performed by the Call Admission Control (CAC) based on QoS operation in the new target cell even though the eNB has received from the UE an RRCConnectionReestablishmentRequest to a different cell from the existing cell.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Y
CC
event
int
0~2147 483647
Granularity Formula
Hourly, Daily, Monthly Formula
197
Chapter 2 Counter Description
E-RAB E-RAB Setup This section provides statistics on the default bearer setup to activate the initial DRB’s radio and S1 bearer. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause
RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: delay_tolerant_access: Access by the delay tolerant access
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
EstabInitAtt Nbr
count
The cumulated number of attempts for E-RAB setup during origination call
This counter is cumulated in the following case during E-RAB setup
Y
CC
event
int
0~2 1474 8364
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
198
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 7
Granularity Formula
Hourly, Daily, Monthly Formula
Success/Failure of E-RAB after receiving InitialContextSetupRequ est EstabInitSu ccNbr
count
The cumulated number of successes for E-RAB setup during origination call
This counter is cumulated in the following case during E-RAB setup Success of E-RAB setup after receiving InitialContextSetupRequ est
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_CpCc To
count
The cumulated number when a call is released due to call control timeout for E-RAB in the origination call.
This counter is cumulated in the following case during E-RAB setup Timeout occurs during internal resource allocation in eNB for UE and integrity activation after InitialContextSetupRequ est is received (timInternalSecurityContr ol_id expired).
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_CpCc Fail
count
The cumulated number when a call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB for E-RAB in the origination call.
This counter is cumulated in the following case during E-RAB setup after receiving InitialContextSetupRequ est In case of signal processing application starting in eNB CSFB is idle or the RAT
Y
CC
event
int
0~2 1474 8364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
199
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
type within the message is not UTRAN, GERAN, and 1xRTT when InitialContextSetupRequ est is received. ErabInitFail Nbr_UpGtp Fail
count
The cumulated number when a call is released due to resource allocation failure in the GTP for E-RAB in the origination call.
This counter is cumulated when the resource allocation fails in the GTP layer for E-RAB setup during origination call after receiving InitialContextSetupRequest message
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_UpMa cFail
count
The cumulated number when a call is released due to resource allocation failure in the MAC for E-RAB in the origination call.
This counter is cumulated when the resource allocation fails in the MAC layer for E-RAB setup during origination call after receiving InitialContextSetupRequest message
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_UpPdc pFail
count
The cumulated number when a call is released due to resource allocation failure in the PDCP for E-RAB in the origination call.
This counter is cumulated when the resource allocation fails in the PDCP layer for E-RAB setup during origination call after receiving InitialContextSetupRequest message
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_UpRlc Fail
count
The cumulated number when a call is released due to resource allocation failure in the RLC or not receiving the ACK for ARQ
This counter is cumulated in the following case during origination call RLCP layer resource
Y
CC
event
int
0~2 1474 8364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
200
Chapter 2 Counter Description Name
Unit
Description
Trigger
from UE for E-RAB in the origination call.
allocation fails during ERAB setup after InitialContextSetupRequ est is received. Cumulated when a minimum number of ARQ ack of the FL traffic packet is not received following E-RAB setup after InitialContextSetupRequ est is received.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabInitFail Nbr_RrcSig Fail
count
The cumulated number when a call is released due to receiving Re-establishmentRequest for E-RAB in the origination call.
This counter is cumulated when ReestablishmentRequest is received before RRCConnectionReconfigur ation Complete is received during E-RAB setup after InitialContextSetupRequest is received in the origination call.
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_RrcSig To
count
The cumulated number when a call is released due to not receiving RRC signal message during RRC setup.
This counter is cumulated in the following case during E-RAB setup after receiving InitialContextSetupRequ est in the origination call Timeout occurs because of not receiving the RRCConnectionReconfig urationComplete after transmitting RRCConnectionReconfig
Y
CC
event
int
0~2 1474 8364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
201
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
uration Timeout occurs because of not receiving SecurityModeComplete after transmitting SecurityModeCommand ErabInitFail Nbr_CpBh CacFail
count
The cumulated number when a call is released due to Backhaul Call Admission Control for ERAB in the origination call.
This counter is cumulated when E-RAB setup is rejected due to Call Admission Control based on the backhaul threshold during E-RAB setup after InitialContextSetupRequest is received in the origination call.
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_CpCa paCacFail
count
The cumulated number when a call is released due to Capacity Call Admission Control for ERAB in the origination call.
This counter is cumulated when E-RAB setup is rejected due to Call Admission Control based on the E-RAB count threshold during E-RAB setup after InitialContextSetupRequest is received in the origination call.
Y
CC
event
int
0~2 1474 8364 7
-
-
ErabInitFail Nbr_CpQo sCacFail
count
The cumulated number when a call is released due to QoS Call Admission Control for E-RAB in the origination call.
This counter is cumulated when E-RAB setup is rejected due to Call Admission Control based on the physical resource block threshold during ERAB setup after InitialContextSetupRequest is received in the
Y
CC
event
int
0~2 1474 8364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
202
Chapter 2 Counter Description Name
Unit
Description
ErabInitFail Nbr_S1ap CuFail
count
The cumulated number when a call is released due to the S1AP specification cause for E-RAB in the origination call.
ErabInitFail Nbr_S1apL inkFail
count
ErabInitFail Nbr_S1apS igFail
count
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated in the following case during E-RAB setup after receiving InitialContextSetupRequ est in the origination call ID of the E-RAB is duplicated. QCI value of the E-RAB is an supported value. E-RAB is GBR but not_present is received as the value of GBRQoSInformationPres ent in the E-RAB information within the S1AP message. Aggregated Maximum Bit Rate (AMBR) is 0 for the DL and UL of the message.
Y
CC
event
int
0~2 1474 8364 7
-
-
The cumulated number when a call is release after receiving ErabSetupRequest for E-RAB, because the status of S1AP is changed to the OOS (Out of server) in the origination call
This counter is cumulated when S1AP communication of the eNB changes to "out of service" during E-RAB setup after InitialContextSetupRequest is received in the origination call.
Y
CC
event
int
0~2 1474 8364 7
-
-
The cumulated number when a call is released due to receiving S1AP message from MME or
This counter is cumulated when Integrity algorithm is EIA0 but the ciphering
Y
CC
event
int
0~2 1474 8364
-
-
origination call.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
203
Chapter 2 Counter Description Name
Unit
Description
Trigger
the security type in the InitialContextSetupRequest is wrong after transmitting ErabSetupRequest for E-RAB setup in the origination call
algorithm is not EEA0 during E-RAB setup after InitialContextSetupRequ est is received in the origination call. This counter is cumulated while receiving S1AP reset command or UEContextReleaseCmd from MME.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 7
Granularity Formula
Hourly, Daily, Monthly Formula
204
Chapter 2 Counter Description
Collection Time (Success) Figure 128. Collection Time for E-RAB Setup UE
eNB
MME
S/GW
RRC_CONNECTED Authentication Procedure (NAS) Security Mode Command
Initial Context Setup Request 1
Attempt
2
Success
Security Mode Complete Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete Initial Context Setup Response
RRC_CONNECTED
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
205
Chapter 2 Counter Description
Collection Time (Failure) Figure 129. Collection Time for ErabInitFailNbr_CpCcTo UE
EPC
eNB
MME
SGW
Initial Context Setup Request
UE context setup
CSFB to not supported RAT type ① ErabInitFailNbr_CpCcFail
Figure 130. Collection Time for ErabInitFailNbr_CpCcFail UE
EPC
eNB
MME Initial Context Setup Request
CSFB to not supported RAT type
SGW UE context setup
① ErabInitFailNbr_CpCcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
206
Chapter 2 Counter Description
Figure 131. Collection Time for ErabInitFailNbr_UpGtpFail EPC
eNB
UE
MME
SGW
Initial Context Setup Request
UECapabilityEnquiry UECapabilityInformation SecurityModeCommand
UECapabilityInfoIndication UE context setup
GTP layer Setup Fail ① ErabInitFailNbr_UpGtpFail
Figure 132. Collection Time for ErabInitFailNbr_UpMacFail eNB
UE
EPC MME
SGW
Initial Context Setup Request
UECapabilityEnquiry UECapabilityInformation SecurityModeCommand
UECapabilityInfoIndication MAC layer Setup Fail
UE context setup
① ErabInitFailNbr_UpMacFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
207
Chapter 2 Counter Description
Figure 133. Collection Time for ErabInitFailNbr_UpPdcpFail eNB
UE
UECapabilityEnquiry UECapabilityInformation SecurityModeCommand
EPC MME Initial Context Setup Request UECapabilityInfoIndication
PDCP layer Setup Fail ① ErabInitFailNbr_UpPdcpFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
SGW
UE context setup
208
Chapter 2 Counter Description
Figure 134. Collection Time for ErabInitFailNbr_UpRlcFail EPC
eNB
UE
MME
SGW
Initial Context Setup Request
UECapabilityEnquiry UECapabilityInformation SecurityModeCommand
UECapabilityInfoIndication UE context setup
RLC Layer Setup Fail ① ErabInitFailNbr_UpRlcFail EPC
eNB
UE
MME
SGW
Connected
.....
Traffic Packet ARQ ack ARQ ack
ARQ ack Not recieved
ARQ ack ① ErabInitFailNbr_UpRlcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
209
Chapter 2 Counter Description
Figure 135. Collection Time for ErabInitFailNbr_RrcSigFail eNB
UE UECapabilityEnquiry UECapabilityInformation
EPC MME
SGW
Initial Context Setup Request UECapabilityInfoIndication
SecurityModeCommand SecurityModeComplete Rrc Connection Reconfiguration ReEstablishment Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
① ErabInitFailNbr_RrcSigFail
210
Chapter 2 Counter Description Figure 136. Collection Time for ErabInitFailNbr_RrcSigTo EPC
eNB
UE
MME
SGW
Initial Context Setup Request
UECapabilityEnquiry UECapabilityInformation
UECapabilityInfoIndication
SecurityModeCommand
Time out
SecurityModeComplete
UE context setup
① ErabInitFailNbr_RrcSigTo eNB
UE
EPC MME
SGW
Rrc Connection Reconfiguration Complete
Time out
Rrc Connection Reconfiguration
① ErabInitFailNbr_RrcSigTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
211
Chapter 2 Counter Description Figure 137. Collection Time for ErabInitFailNbr_CpBhCacFail UE
EPC
eNB
MME
SGW
Initial Context Setup Request UE context setup
Rejected By BH CAC ① ErabInitFailNbr_CpBhCacFail
Figure 138. Collection Time for ErabInitFailNbr_CpCapaCacFail UE
EPC
eNB
MME
SGW
Initial Context Setup Request Rejected By Capacity CAC
UE context setup
① ErabInitFailNbr_CpCacaCacFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
212
Chapter 2 Counter Description Figure 139. Collection Time for ErabInitFailNbr_CpQosCacFail UE
EPC
eNB
MME
SGW
Initial Context Setup Request UE context setup
Rejected By QoS CAC ① ErabInitFailNbr_CpQosCacFail
Figure 140. Collection Time for ErabInitFailNbr_S1apCuFail UE
eNB
EPC MME
SGW
Initial Context Setup Request Invalid E-RAB Info.
UE context setup
① ErabInitFailNbr_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
213
Chapter 2 Counter Description Figure 141. Collection Time for ErabInitFailNbr_S1apLinkFail EPC
eNB
UE
MME
SGW
Connected
Out Of Service ① ErabInitFailNbr_S1apLinkFail
Figure 142. Collection Time for ErabInitFailNbr_S1apSigFail UE
EPC
eNB
MME
SGW
Initial Context Setup Request
UE context setup
Integrity algorithm == EIA0 && Ciphering algorithm != EEA0 ① ErabInitFailNbr_S1apSigFail UE
eNB
EPC MME
SGW
UE Context Release Command (or S1AP Reset) ① ErabInitFailNbr_S1apSigFail
For E-RAB setup count statistics, Attempt is counted when the Initial Context Setup Request message is received during the initial call setup, and Success is counted when the Initial Context Setup Response message is transmitted. A failure is counted when a timeout or failure occurs during the procedure and the applicable cause value is recorded. Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
214
Chapter 2 Counter Description
E-RAB Setup Add This section provides statistics on the number of additional E-RAB (dedicated bearer) setups by the MME following the initial default bearer setup. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EstabAddAttNbr
count
The cumulated number of attempts for E-RAB setup during origination call
This counter is cumulated in the following cases during E-RAB setup Success/Failure of E-RAB after receiving ErabSetupRequest message
Y
CC
event
int
0~21474 83647
-
-
EstabAddSuccN br
count
The cumulated number of successes for E-RAB setup during origination call
This counter is cumulated in the following cases during E-RAB setup Success of E-RAB after receiving ErabSetupRequest message
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr
count
The cumulated number
This counter is
Y
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
215
Chapter 2 Counter Description Name
Unit
_CpCcTo
Description
Trigger
when a call is released due to call control timeout for ERAB in the origination call.
cumulated in the following cases during E-RAB setup This counter is cumulated when the eNB allocates internal resouce, timeout occurs after receiving ErabSetupRequest message. (timInternalResourceS etup_id expired)
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
ErabAddFailNbr _CpCcFail
count
The cumulated number when a call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB for ERAB in the origination call.
This counter is cumulated in the following cases during E-RAB setup after receiving ErabSetupRequest message When signal processing application restarts in eNB
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _UpGtpFail
count
The cumulated number when a call is released due to resource allocation failure in the GTP for E-RAB in the origination call.
This counter is cumulated when the resource allocation of GTP layer failed during E-RAB setup after receiving the ErabSetupRequest message in the origination call
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr
count
The cumulated number when a call is released due
This counter is cumulated when the
Y
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
216
Chapter 2 Counter Description Name
Unit
_UpMacFail
Description
Trigger
to resource allocation failure in the MAC for E-RAB in the origination call.
resource allocation of MAC layer failed during E-RAB setup after receiving the ErabSetupRequest message in the origination call
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
ErabAddFailNbr _UpPdcpFail
count
The cumulated number when a call is released due to resource allocation failure in the PDCP for E-RAB in the origination call.
This counter is cumulated when the resource allocation of PCDP layer failed during E-RAB setup after receiving the ErabSetupRequest message in the origination call
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _UpRlcFail
count
The cumulated number when a call is released due to resource allocation failure in the RLC or not receiving the ACK for ARQ from UE for E-RAB in the origination call.
This counter is cumulated in the following cases during origination call RLCP layer resource allocation fails during E-RAB setup after an ErabSetupRequest message is received. Cumulated when a minimum number of ARQ ack of the FL traffic packet is not received following E-RAB setup after an
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
217
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabSetupRequest message is received. ErabAddFailNbr _RrcSigFail
count
The cumulated number when a call is released due to receiving ReestablishmentRequest for ERAB in the origination call.
This counter is cumulated when ReestablishmentRequest is received before RRCConnectionReco nfiguration Complete is received during ERAB setup after an ErabSetupRequest message is received in the origination call.
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _RrcSigTo
count
The cumulated number when a call is released due to not receiving RRC signal message during RRC setup.
This counter is cumulated in the following case during E-RAB setup after receiving ErabSetupRequest message. Timeout occurs due to not receiving the RRCConnectionRec onfigurationComplet e message after transmitting RRCConnectionRec onfiguration
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _CpBhCacFail
count
The cumulated number when a call is released due to Backhaul Call Admission Control for E-RAB in the
This counter is cumulated in the following case during E-RAB setup after receiving
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
218
Chapter 2 Counter Description Name
Unit
Description
Trigger
origination call.
ErabSetupRequest message in the origination call Cumulated when ERAB setup is rejected due to Call Admission Control based on the backhaul threshold.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabAddFailNbr _CpCapaCacFai l
count
The cumulated number when a call is released due to Capacity Call Admission Control for E-RAB in the origination call.
This counter is cumulated in the following case during E-RAB setup after receiving ErabSetupRequest message in the origination call Cumulated when ERAB setup is rejected due to Call Admission Control based on the ERAB count threshold.
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _CpQosCacFail
count
The cumulated number when a call is released due to QoS Call Admission Control for E-RAB in the origination call.
This counter is cumulated in the following case during E-RAB setup after receiving ErabSetupRequest message in the origination call E-RAB setup is
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
219
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
rejected due to Call Admission Control based on the physical resource block threshold. ErabAddFailNbr _S1apCuFail
count
The cumulated number when a call is released due to the S1AP specification cause for E-RAB in the origination call.
This counter is cumulated in the following case during E-RAB setup after receiving ErabSetupRequest message ID of the E-RAB is duplicated. QCI value of the ERAB is an supported value. E-RAB is GBR but not_present is received as the value of GBRQoSInformatio nPresent in the ERAB information within the S1AP message. Aggregated Maximum Bit Rate (AMBR) is 0 for the DL and UL of the message.
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _S1apLinkFail
count
The cumulated number when a call is release after
This counter is cumulated when
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
220
Chapter 2 Counter Description Name
Unit
Description
Trigger
receiving ErabSetupRequest for ERAB, because the status of S1AP is changed to the OOS (Out of server) in the origination call
S1AP communication of the eNB changes to 'out of service' during E-RAB setup after an ErabSetupRequest message is received in the origination call.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabAddFailNbr _S1apSigFail
count
The cumulated number when a call is released due to receiving S1AP message from MME after transmitting ErabSetupRequest for ERAB setup in the origination call
This counter is cumulated when receiving the UEContextReleaseC md or S1AP reset command from MME during E-RAB Setup procedure
Y
CC
event
int
0~21474 83647
-
-
ErabAddFailNbr _CpCcInteractio n
count
The cumulated number of E-RAB failures during Intra LTE or InterRat handover
This counter is cumulated in the following cases after receiving the ErabSetupRequest message during INTER RAT handover during INTRA LTE handover (via source eNB)
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
221
Chapter 2 Counter Description
Collection Time Figure 143. Collection Time for ErabAddFailNbr_CpCcTo EPC
eNB
UE
MME
SGW
Time out
ERAB Setup Request
E_RAB Setup
Resource Allocation … Fail ① ErabAddFailNbr_CpCcTo
Figure 144. Collection Time for ErabAddFailNbr_CpCcFail UE
EPC
eNB
MME ERAB Setup Request
SGW E_RAB Setup
Application Restart ① ErabAddFailNbr_CpCcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
222
Chapter 2 Counter Description
Figure 145. Collection Time for ErabAddFailNbr_UpGtpFail UE
EPC
eNB
MME
SGW
ERAB Setup Request
E_RAB Setup
GTP layer Setup Fail ① ErabAddFailNbr_UpGtpFail
Figure 146. Collection Time for ErabAddFailNbr_UpMacFail UE
EPC
eNB
MME ERAB Setup Request
SGW E_RAB Setup
MAC layer Setup Fail ① ErabAddFailNbr_UpMacFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
223
Chapter 2 Counter Description
Figure 147. Collection Time for ErabAddFailNbr_UpPdcpFail UE
EPC
eNB
MME ERAB Setup Request
SGW E_RAB Setup
PDCP layer Setup Fail ① ErabAddFailNbr_UpPdcpFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
224
Chapter 2 Counter Description Figure 148. Collection Time for ErabAddFailNbr_UpRlcFail EPC
eNB
UE
MME
SGW
ERAB Setup Request RLCP layer Setup Fail
E_RAB Setup
① ErabAddFailNbr_UpRlcFail
eNB
UE
EPC MME
SGW
Connected
...... .
Traffic Packet ARQ ack ARQ ack
ARQ ack Not recieved
ARQ ack ① ErabAddFailNbr_UpRlcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
225
Chapter 2 Counter Description
Figure 149. Collection Time for ErabAddFailNbr_RrcSigFail EPC
eNB
UE Rrc Connection Reconfiguration
MME
SGW
ERAB Setup Request
ReEstablishment
① ErabAddFailNbr_RrcSigFail
Rrc Connection Reconfiguration Complete
Figure 150. Collection Time for ErabAddFailNbr_RrcSigTo EPC
eNB
UE Rrc Connection Reconfiguration
MME
SGW
Time out
ERAB Setup Request
Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
① ErabAddFailNbr_RrcSigTo
226
Chapter 2 Counter Description
Figure 151. Collection Time for ErabAddFailNbr_CpBhCacFail UE
EPC
eNB
MME
SGW
ERAB Setup Request Rejected By BH CAC
UE context setup
① ErabAddFailNbr_CpBhCacFail
Figure 152. Collection Time for ErabAddFailNbr_CpCapaCacFail UE
EPC
eNB
MME
SGW
ERAB Setup Request Rejected By Capacity CAC
UE context setup
① ErabAddFailNbr_CpCapaCacFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
227
Chapter 2 Counter Description Figure 153. Collection Time for ErabAddFailNbr_CpQosCacFail EPC
eNB
UE
MME
SGW
ERAB Setup Request Rejected By QoS CAC
UE context setup
① ErabAddFailNbr_CpQosCacFail
Figure 154. Collection Time for ErabAddFailNbr_S1apCuFail EPC
eNB
UE
MME
SGW
ERAB Setup Request Invalid E-RAB Info.
UE context setup
① ErabAddFailNbr_S1apCuFail
Figure 155. Collection Time for ErabAddFailNbr_S1apLinkFail UE
EPC
eNB
MME
SGW
ERAB Setup Request ① ErabAddFailNbr_S1apLinkFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Out Of Service
228
Chapter 2 Counter Description Figure 156. Collection Time for ErabAddFailNbr_S1apSigFail UE
eNB
EPC MME
SGW
ERAB Setup Request UE Context Release Command (or S1AP Reset) ① ErabAddFailNbr_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
229
Chapter 2 Counter Description
Figure 157. Collection Time for ErabAddFailNbr_CpCcInteraction UE
TeNB or Other RAT
SeNB
EPC MME
SGW
Handover Request
Handover Request Acknowledge Rrc Connection Reconfiguration
X2 HO ERAB Setup Request
E-RAB Add fail
① ErabAddFailNbr_CpCcInteraction
UE
TeNB or Other RAT
SeNB
EPC MME
SGW
Handover Required Handover Request Handover Request Acknowledge Rrc Connection Reconfiguration
S1 HO
Handover Command ERAB Setup Request E-RAB Add fail
① ErabAddFailNbr_CpCcInteraction
For additional E-RAB setup count statistics, Attempt is counted when the E-RAB Setup Request message is received during the additional E-RAB setup, and Success is counted when the E-RAB Setup Response message is transmitted. A Failure is counted when a timeout or failure occurs during the procedure and the applicable cause value is recorded.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
230
Chapter 2 Counter Description
E-RAB Setup Time This section provides statistics on the average E-RAB Setup time and the maximum E-RAB Setup time for each cell. Collects when the initial E-RAB Setup procedure and additional E-RAB Setup procedure. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EstabTimeAvg
ms
The average ERAB setup time (ms)
The time is increased in the following cases. The time duration between the received InitialContextSetupRequest and the transmitted InitialContextSetupResponse The time duration between the received ErabSetupRequest and the transmitted ErabSetupResponse
Y
GAUGE
event
int
0~21474 83647
EstabTime Tot/EstabTi meCnt
sum(EstabTimeTot)/su m(EstabTimeCnt)
EstabTimeMax
ms
The maximum number of EstabTime
This counted is updated when EstabTime is collected and it it greater than previous
Y
GAUGE
event
int
0~60*Pe riod*100 0
-
max(EstabTimeMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
231
Chapter 2 Counter Description Name
Unit
Description
Trigger
EstabTimeTot
ms
The cumulated number of EstabTime
EstabTimeCnt
cou nt
The cumulated collection count of EstabTime
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when EstabTime is collected
Y
GAUGE
event
int
0~21474 83647
-
-
This counter is cumulated when EstabTime is collected
Y
GAUGE
event
int
0~21474 83647
-
-
maximum value
Collection Time Figure 158. Collection Time for E-RAB Setup time UE
eNB
MME
S/GW
RRC_IDLE
Security Mode Command
Initial Context Setup Request
Security Mode Complete RRC Connection Reconfiguration
E-RAB Setup time
RRC Connection Reconfiguration Complete Initial Context Setup Response RRC_CONNECTED
The E-RAB setup time indicates the duration from receiving the Initial Context Setup Request message up to transmitting the Initial Context Setup Response, which is reported in milliseconds. The statistics block calculates the average and maximum values of the setup time during the collection period. Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
232
Chapter 2 Counter Description
E-RAB Erase Request This section provides statistics on the E-RAB release requests made by the eNB by transmitting the UE Context Release Request message. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EraseAttbyEnb _CpCcTo
count
The cumulated number of call releases since the timer expires during resource allocation in E-RAB setup.
This count is cumulated when timeout occurs during releasing the resource in eNB.
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _CpCcFail
count
The cumulated number of call releases due to eNB failure.
This counter is cumulated when a call is released due to restarting of signal processing application in eNB
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _UpGtpFail
count
The cumulated number of call releases due to a failure of GTP layer resource release during E-RAB
This counter is cumulated when fails to allocate the resource of GTP layer during E-RAB release.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
233
Chapter 2 Counter Description Name
Unit
EraseAttbyEnb _UpMacFail
count
EraseAttbyEnb _UpMacUEIna ct
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The cumulated number of call releases due to a failure of MAC layer resource release during E-RAB release.
This counter is cumulated when a call is releaed due to resource allocation of MAC Layer failure during E-RAB release
Y
CC
event
int
0~2147483647
-
-
count
The cumulated number of call releases due to UE inactivity.
This counter is cumulated when a call is released in the following case No packet for specific time duration in the DL/UL
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _UpPdcpFail
count
The cumulated number of call releases due to a failure of PDCP layer resource release during ERAB release.
This counter is cumulated when a call is released due to allocation failure of the PDCP layer during ERAB release
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _UpRlcFail
count
The cumulated number of call releases due to a failure of RLC layer resource release during E-RAB setup.
This counter is cumulated when a call is released due to allocation failure of the RLC layer during ERAB release
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _RrcHcTo
count
The cumulated number when a timer occurs for the RRC message from the target eNB
This counter is cumulated when a call is released in the following case Patch setup does not occur within a certain
Y
CC
event
int
0~2147483647
-
-
release.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
234
Chapter 2 Counter Description Name
Unit
Description
Trigger
during handover.
period of time during intra eNB handover. The target eNB does not received a completion message for RRCConnectionReconf iguration within a certain period of time during S1 handover. The target eNB does not received a completion message for RRCConnectionReconf iguration within a certain period of time during X2 handover.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EraseAttbyEnb _RrcSigFail
count
The cumulated number of call releases due to receiving ReestablishmentReque st during E-RAB release.
This counter is cumulated when a call release occurs due to receiving ReestablishmentRequest before RRCConnectionReconfig uration Complete is received during E-RAB release.
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _RrcSigTo
count
The cumulated number of call releases due to not receiving a RRC signal message within a certain period of time during E-RAB release.
This counter is cumulated when a call release occurs due to not receiving RRCConnectionReconfig urationComplete within a certain period of time after
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
235
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RRCConnectionReconfig uration is transmitted during E-RAB release. EraseAttbyEnb _S1apCuFail
count
The cumulated number of call releases due to receiving abnormal E-RAB information of the cause defined in the S1AP specifications during E-RAB setup.
This counter is cumulated when E-RAB is released due to the S1AP specification cause
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _S1apRoTo
count
The cumulated number of timeouts that occur for resource allocation during handover.
This counter is cumulated when a call is released in the following case. Cumulated when resource allocation for data forwarding is not performed within a certain period of time after the source eNB receives S1apHandoverComma nd_id and transmits RCConnectionReconfig uration during S1 handover.
Y
CC
event
int
0~2147483647
-
-
EraseAttbyEnb _S1apSigTo
count
The cumulated number of timeouts that occur for the S1AP message during handover.
This counter is cumulated when a call is released as following case. InitialContextSetupRequ est is not received within a certain period
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
236
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
of time after RRCConnectionSetup Complete is received during the InitialContextSetup procedure. The eNB does not receive RRCConnectionReconf igurationComplete from the UE after receiving MME Status Transfer from MME during S1 handover. EraseAttbyEnb _X2apRoTo
count
The cumulated number of timeouts that occur for resource allocation during handover.
This counter is cumulated when resource allocation for data forwarding is not performed within a certain period of time after the source eNB receives X2apHandoverRequestA cknowledge during X2 handover.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
237
Chapter 2 Counter Description
Collection Time (Success) Figure 159. Collection Time for E-RAB Erase Request UE
eNB
MME
S/GW
RRC_CONNECTED UE Context Release Request Count
1 UE Context Release Command
RRC Connection Release UE Context Release Complete RRC_CONNECTED
The eNB E-RAB erase request refers to deleting the UE context. When the eNB needs to release the UE context, it transmits the UE Context Release Request message to the MME, and counts statistics.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
238
Chapter 2 Counter Description
Collection Time (Failure) Figure 160. Collection Time for EraseAttbyEnb_CpCcTo EPC
eNB
UE
MME
SGW
Time out
E-RAB Release Resource Release ...Fail ERAB Setup Request ① EraseAttbyEnb_CpCcTo
Figure 161. Collection Time for EraseAttbyEnb_CpCcFail UE
EPC
eNB
MME
SGW
E-RAB Release Application Restart Context Release Request ① EraseAttbyEnb_CpCcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
239
Chapter 2 Counter Description Figure 162. Collection Time for EraseAttbyEnb_UpGtpFail UE
EPC
eNB
MME
SGW
E-RAB Release GTP layer release Fail Context Release Request ① EraseAttbyEnb_UpGtpFail
Figure 163. Collection Time for EraseAttbyEnb_UpMacFail UE
EPC
eNB
MME
SGW
E-RAB Release MAC layer release Fail Context Release Request ① EraseAttbyEnb_UpMacFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
240
Chapter 2 Counter Description Figure 164. Collection Time for EraseAttbyEnb_UpMacUEInact EPC
eNB
UE
MME
SGW
E-RAB Release Packet Packet
Inactive
Packet UE context setup Context Release Request ① EraseAttbyEnb_UpMacUeInact
Figure 165. Collection Time for EraseAttbyEnb_UpPdcpFail UE
EPC
eNB
MME
SGW
E-RAB Release PDCP layer release Fail Context Release Request ① EraseAttbyEnb_UpPdcpFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
241
Chapter 2 Counter Description Figure 166. Collection Time for EraseAttbyEnb_UpRlcFail UE
EPC
eNB
MME
SGW
E-RAB Release RLC layer Release Fail Context Release Request ① EraseAttbyEnb_UpRlcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
242
Chapter 2 Counter Description
Figure 167. Collection Time for EraseAttbyEnb_RrcHcTo UE
SeNB
TeNB
EPC MME
SGW
Handover Request X2 HO
Handover Acknowledge
Complete
Time out
RrcConnectionReconfiguration
Context Release Request ① EraseAttbyEnb_RrcHCTo
UE
SeNB
TeNB
EPC MME
Handover Required Handover Request
SGW
S1 HO
Handover Acknowledge
Complete
Handover Command
Time out
RrcConnectionReconfiguration
Context Release Request ① EraseAttbyEnb_RrcHcTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
243
Chapter 2 Counter Description
Figure 168. Collection Time for EraseAttbyEnb_RrcSigFail EPC
eNB
UE
MME
SGW
E-RAB Release start Rrc Connection Reconfiguration ReEstablishment Rrc Connection Reconfiguration Complete
Context Release Request ① EraseAttbyEnb_RrcSigFail
Figure 169. Collection Time for EraseAttbyEnb_RrcSigTo EPC
eNB
UE
MME
SGW
E-RAB Release start
Rrc Connection Reconfiguration Complete
Time out
Rrc Connection Reconfiguration
Context Release Request ① EraseAttbyEnb_RrcSigTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
244
Chapter 2 Counter Description
Figure 170. Collection Time for EraseAttbyEnb_S1apCuFail EPC
eNB
UE
MME
SGW
E-RAB Release S1AP Spec. Cause Context Release Request ① EraseAttbyEnb_S1apCuFail
Figure 171. Collection Time for EraseAttbyEnb_S1apRoTo UE
TeNB Rrc Connection Reconfiguration Complete
SeNB
EPC MME
SGW
Handover Command
Fail to allocate Resource for Data forwarding Context Release Request ① EraseAttbyEnb_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
245
Chapter 2 Counter Description
Figure 172. Collection Time for EraseAttbyEnb_S1apSigTo EPC
eNB
UE
MME
SGW
Rrc Connection Request Rrc Connection Setup Rrc Connection Setup Complete
Time out
Attach Request Initial Context Setup Request
Context Release Request ① EraseAttbyEnb_S1apSigTo
UE
SeNB
TeNB
EPC MME
SGW
Rrc Connection Reconfiguration eNB Status Transfer
Complete
Time out
MME Status Transfer
Context Release Request ① EraseAttbyEnb_S1apSigTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
246
Chapter 2 Counter Description
Figure 173. Collection Time for EraseAttbyEnb_X2apRoTo UE
SeNB
TeNB
EPC MME
SGW
Handover Request Handover Acknowledge Fail to allocate Resource for Data forwarding Context Release Request ① EraseAttbyEnb_X2apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
247
Chapter 2 Counter Description
E-RAB Erase This section provides statistics on the E-RAB release requests made by the eNB using the UE Context Release command. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EraseAtt
count
The cumulated number of UEContextRelease attempts from MME.
This counter is cumulated when receiving the UEContextRelease from MME.
Y
CC
event
int
0~2147483647
-
-
EraseSucc
count
The cumulated number of UEContextRelease success from MME.
This counter is cumulated when deallocating the resource in eNB after receiving UEContextRelease from MME and transmitted the UEContextRelease Complete to MME
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
248
Chapter 2 Counter Description
Collection Time Figure 174. Collection Time for E-RAB erase UE
eNB
MME
S/GW
RRC_CONNECTED UE Context Release Command Attempt
1
Rrc Connection Release UE Context Release Complete Success
2 RRC_CONNECTED
For E-RAB ERASE statistics, an Attempt is counted when the UE Context Release Command is received, and Success is counted when the UE Context Release Complete message is transmitted.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
249
Chapter 2 Counter Description
E-RAB Modify This section provides statistics on the E-RAB Modify attempt/success/modify for each cell after InitialContextSetup during origination call. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ModQoSAtt Nbr
count
The cumulated number when E-RAB modify is attempted in the origination call.
This counter is cumulated when succeed (or failed) ERAB modify after receiving ErabModifyRequest message.
Y
CC
event
int
0~2147483 647
-
-
ModQoSSu ccNbr
count
The cumulated number when E-RAB modify is successful in the origination call.
This counter is cumulated when succeed E-RAB modify after receiving ErabModifyRequest message.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_CpCc
count
The cumulated number when the timer expires
This counter is cumulated when
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
250
Chapter 2 Counter Description Name
Unit
To
Description
Trigger
during E-RAB modify in the origination call.
timeout occurs during internal resource allocation in eNB (timInternalResource Setup_id expired) after an ErabModifyRequest message is received.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ModQoSFa ilNbr_CpCc Fail
count
The cumulated number of eNB failures or CSFB failures during E-RAB modify in the origination call.
This counter is cumulated in the following case during E-RAB modify after an ErabModifyRequest message is received. Signal processing application within eNB is restarted.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_UpGt pFail
count
The cumulated number of GTP layer resource allocation failures during E-RAB modify in the origination call.
This counter is cumulated when GTP layer resource allocation failed during E-RAB modify after receiving ErabModifyRequest message in the origination call
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_UpM acFail
count
The cumulated number of MAC layer resource allocation failures during E-RAB modify in the origination call.
This counter is cumulated when MAC layer resource allocation failed during E-RAB modify after receiving
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
251
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabModifyRequest message in the origination call ModQoSFa ilNbr_UpPd cpFail
count
The cumulated number of PDCP layer resource allocation failures during E-RAB modify in the origination call.
This counter is cumulated when PDCP layer resource allocation failed during E-RAB modify after receiving ErabModifyRequest message in the origination call
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_UpRl cFail
count
The cumulated number when the ack of the ARQ is not received from the UE or during ERAB modify in the origination call.
This counter is cumulated when a call is released in the following case. RLCP layer resource allocation fails during E-RAB modify after an ErabModifyReques t message is received. Cumulated when a minimum number of ARQ ack of the FL traffic packet is not received following E-RAB modify after an ErabModifyReques t message is received.
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
252
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ModQoSFa ilNbr_RrcSi gFail
count
The cumulated number of ReestablishmentRequest messages received during E-RAB modify in the origination call.
This counter is cumulated when ReestablishmentReque st is received before RRCConnectionRec onfiguration Complete is received during E-RAB modify after an ErabModifyRequest message is received in the origination call.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_RrcSi gTo
count
The cumulated number when a RRC signal message is not received within a certain period of time during E-RAB modify in the origination call.
This counter is cumulated in the following case during E-RAB modify after the ErabModifyRequest message is received in the origination call. Timeout occurs due to not receiving RRCConnectionRe configurationComp lete after RRCConnectionRe configuration is transmitted.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_CpBh CacFail
count
The cumulated number when E-RAB setup is rejected due to backhaul call admission control during E-RAB modify in the origination call.
This counter is cumulated when ERAB setup is rejected due to Call Admission Control based on the
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
253
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
backhaul threshold during E-RAB setup after an ErabModifyRequest message is received in the origination call. ModQoSFa ilNbr_CpCa paCacFail
count
The cumulated number when E-RAB setup is rejected due to capacity call admission control during E-RAB modify in the origination call.
This counter is cumulated when ERAB setup is rejected due to Call Admission Control based on the E-RAB count threshold during E-RAB setup after an ErabModifyRequest message is received in the origination call.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_CpQo sCacFail
count
The cumulated number when E-RAB setup is rejected due to QoS call admission control during E-RAB modify in the origination call.
This counter is cumulated when ERAB setup is rejected due to Call Admission Control based on the physical resource block threshold during E-RAB setup after an ErabModifyRequest message is received in the origination call.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_S1ap CuFail
count
The cumulated number when abnormal E-RAB information of the cause
This counter is cumulated in the following case during
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
254
Chapter 2 Counter Description Name
ModQoSFa ilNbr_S1ap LinkFail
Unit
count
Description
Trigger
defined in the S1AP specifications is received during E-RAB modify in the origination call.
E-RAB setup after an ErabModifyRequest message is received in the origination call. ID of the E-RAB is duplicated. QCI value of the ERAB is an unsupported value. E-RAB is GBR but not_present is received as the GBRQoSInformati onPresent value in the E-RAB information within the S1AP message. Aggregated Maximum Bit Rate (AMBR) is 0 for the DL and UL of the message.
The cumulated number when S1AP communication of the eNB is out of service during E-RAB setup after an ErabModifyRequest message is received in the origination call.
This counter is cumulated when S1AP communication of the eNB is out of service during E-RAB setup after an ErabModifyRequest message is received in the origination call.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483 647
-
-
255
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ModQoSFa ilNbr_S1ap SigFail
count
The cumulated number of S1AP messages received from MME during E-RAB setup after an ErabModifyRequest message is received in the origination call.
This counter is cumulated when S1AP messages received from MME during E-RAB setup after an ErabModifyRequest message is received in the origination call.
Y
CC
event
int
0~2147483 647
-
-
ModQoSFa ilNbr_CpCc Interaction
count
The cumulated number when E-RAB modify fails during Inter LTE or Inter RAT handover.
This counter is cumulated when ERAB modify fails during Intra LTE or Inter RAT handover. Inter RAT Handover received from source eNB during Intra LTE Handover
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
256
Chapter 2 Counter Description
Collection Time (Success) Figure 175. Collection Time for E-RAB modify UE
eNB
MME
S/GW
RRC_CONNECTED E-RAB Modify Request Attempt
1
Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete Success
2
E-RAB Modify Response
RRC_CONNECTED
For E-RAB Modify statistics, Attempt is counted when the E-RAB Modify Request message is received from the MME, and Success is counted when the E-RAB Modify Response message is transmitted. A Failure is counted when the E-RAB Modify procedure fails due to an internal timeout or failure, and the applicable cause value is recorded.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
257
Chapter 2 Counter Description
Collection Time (Failure) Figure 176. Collection Time for ModQoSFailNbr_CpCcTo EPC
eNB
UE
MME
SGW
Time out
ERAB Modify Request Resource Allocation … Fail ① ModQoSFailNbr_CpCTo
Figure 177. Collection Time for ModQoSFailNbr_CpCcFail UE
EPC
eNB
MME
SGW
ERAB Modify Request Application Restart ① ModQoSFailNbr_CpCcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
258
Chapter 2 Counter Description Figure 178. Collection Time for ModQoSFailNbr_UpGtpFail UE
EPC
eNB
MME
SGW
ERAB Modify Request GTP layer Setup Fail ① ModQoSFailNbr_UpGtpFail
Figure 179. Collection Time for ModQoSFailNbr_UpMacFail UE
EPC
eNB
MME
SGW
ERAB Modify Request MAC layer Setup Fail ① ModQoSFailNbr_UpMacFail
Figure 180. Collection Time for ModQoSFailNbr_UpPdcpFail UE
EPC
eNB
MME
SGW
ERAB Modify Request PDCP layer Setup Fail ① ModQoSFailNbr_UpPdcpFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
259
Chapter 2 Counter Description Figure 181. Collection Time for ModQoSFailNbr_UpRlcFail EPC
eNB
UE
MME
SGW
ERAB Modify Request RLCP layer Setup Fail ① ModQoSFailNbr_UpRlcFail
eNB
UE
EPC MME
SGW
Connected
......
Traffic Packet ARQ ack ARQ ack
ARQ ack Not recieved
ARQ ack ① ModQoSFailNbr_UpRlcFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
260
Chapter 2 Counter Description
Figure 182. Collection Time for ModQoSFailNbr_RrcSigFail EPC
eNB
UE Rrc Connection Reconfiguration
MME
SGW
ERAB Modify Request
ReEstablishment
① ModQoSFailNbr_RrcSigFail
Rrc Connection Reconfiguration Complete
Figure 183. Collection Time for ModQoSFailNbr_RrcSigTo EPC
eNB
UE Rrc Connection Reconfiguration
MME
SGW
Time out
ERAB Modify Request
Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
① ModQoSFailNbr_RrcSigTo
261
Chapter 2 Counter Description Figure 184. Collection Time for ModQoSFailNbr_CpBhCacFail UE
EPC
eNB
MME
SGW
ERAB Modify Request Rejected By BH CAC ① ModQoSFailNbr_CpBhCacFail
Figure 185. Collection Time for ModQoSFailNbr_CpCapaCacFail UE
EPC
eNB
MME
SGW
ERAB Modify Request Rejected By Capacity CAC ① ModQoSFailNbr_CpCapaCacFail
Figure 186. Collection Time for ModQoSFailNbr_CpQosCacFail UE
EPC
eNB
MME
SGW
ERAB Modify Request Rejected By QoS CAC ① ModQoSFailNbr_CpQosCacFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
262
Chapter 2 Counter Description Figure 187. Collection Time for ModQoSFailNbr_S1apCuFail UE
EPC
eNB
MME
SGW
ERAB Modify Request Invalid E-RAB Info. ① ModQoSFailNbr_S1apCuFail
Figure 188. Collection Time for ModQoSFailNbr_S1apLinkFail UE
EPC
eNB
MME
SGW
ERAB Modify Request Out Of Service ① ModQoSFailNbr_S1apLinkFail
Figure 189. Collection Time for ModQoSFailNbr_S1apSigFail UE
eNB
EPC MME
SGW
ERAB Modify Request UE Context Release Command (or S1AP Reset) ① ModQoSFailNbr_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
263
Chapter 2 Counter Description
Figure 190. Collection Time for ModQoSFailNbr_CpCcInteraction UE
TeNB or Other RAT
SeNB
EPC MME
SGW
Handover Request
Handover Request Acknowledge Rrc Connection Reconfiguration
X2 HO ERAB Modify Request
E-RAB Add fail
① ModQoSFailNbr_CpCcInteraction
UE
TeNB or Other RAT
SeNB Handover Request
EPC MME
SGW
Handover Required
Handover Request
S1 HO
Handover Request Acknowledge Rrc Connection Reconfiguration
Handover Command ERAB Modify Request E-RAB Add fail
① ModQoSFailNbr_CpCcInteraction
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
264
Chapter 2 Counter Description
E-RAB Release Request This section provides statistics on the E-RAB release requests made by the eNB using the E-RAB Release Indication message for each cell. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RelAttbyEnbN br_CpCcTo
count
The cumulated number when the eNB attempts ERAB release since eNB internal resource allocation has failed.
This counter is cumulated when E_RABReleaseIndicati on is transmitted to MME due to a timeout that occurs during internal resource release in eNB.
Y
CC
event
int
0~21474 83647
-
-
RelAttbyEnbN br_S1apCuFail
count
The cumulated number when the eNB attempts ERAB release due to a S1AP specification cause.
This counter is cumulated when eNB transmitted RABReleaseIndication to MME due the S1AP specification cause
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
265
Chapter 2 Counter Description
Collection Time (Success) Figure 191. Collection Time for eNB E-RAB release request UE
eNB
MME
S/GW
RRC_CONNECTED
Count
1
Rrc Connection Reconfiguration
E-RAB Release Indication E-RAB Release Command
Rrc Connection Reconfiguration Complete E-RAB Release Response RRC_CONNECTED
The eNB E-RAB Release statistics are counted when the eNB deletes the applicable bearers as needed and transmits the E-RAB Release Indication message to the MME.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
266
Chapter 2 Counter Description
Collection Time (Failure) Figure 192. Collection Time for RelAttbyEnbNbr_CpCcTo EPC
eNB
UE
MME
SGW
Time out
E-RAB Release start S1AP Spec. Cause E_RAB Release Indication ① RelAttbyEnbNbr_CpCcTo
Figure 193. Collection Time for RelAttbyEnbNbr_S1apCuFail UE
EPC
eNB
MME
SGW
E-RAB Release start UE Context Release Command (S1AP Spec. cause) E_RAB Release Indication ① RelAttbyEnbNbr_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
267
Chapter 2 Counter Description
E-RAB Release This section provides statistics for each Cell on the E-RAB releases using the E-RAB Release command from MME to eNB. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RelAttNbr
count
The cumulated number when the E-RAB release command is received by the eNB.
This counter is cumulated when eNB received the ERAB release command from MME
Y
CC
event
int
0~2147 483647
-
-
RelSuccNbr
count
The cumulated number when a response to the E-RAB release command is transmitted to MME.
This counter is cumulated when eNB transmitted ERAB release response message, after receiving the E-RAB and release ERAB normally.
Y
CC
event
int
0~2147 483647
-
-
RelFailNbr_ CpCcFail
count
The cumulated number of call releases due to eNB failure during E-RAB release command processing.
This counter is cumulated when a call is released due to restart of signal processing application in eNB, after receiving ERAB release command
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
268
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RelFailNbr_ S1apSigFail
count
The cumulated number of S1AP messages received from MME during E-RAB release command processing.
This counter is cumulated when a call is released due to receiving UEContextReleaseCmd or S1AP reset command from MME after receiving E-RAB release command
Y
CC
event
int
0~2147 483647
-
-
RelFailNbr_ S1apCuFail
count
The cumulated number of releases due to a S1AP specification cause received from MME during E-RAB release command processing.
This counter is cumulated when a call is released due to S1AP specification cause during E-RAB release after receiving ERAB release command from MME
Y
CC
event
int
0~2147 483647
-
-
RelActive
count
The cumulated number of releases due to an abnormal internal operation of the eNB in the setup E-RAB.
This counter is cumulated as number of active ERABs, for which a call is released due to abnormal operation in eNB.
Y
CC
event
int
0~2147 483647
-
-
RelFailNbr_ CpCcInteract ion
count
The cumulated number of ERAB releases during handover.
This count is cumulated when E-RAB setup is failed because E-RAB Release command is received in the following case. INTER RAT handover The source eNB received E-RAB release command during INTRA LTE handover
Y
CC
event
int
0~2147 483647
-
-
The cumulated number about established E-RABs when a call is released as a result of
This counter is cumulated about established E-RABs when a call is a released
Y
CC
event
int
0~2147 483647
-
-
RelActive_E ccbRadioLin
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
269
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
kFailure
not receiving HARQ ACK notification from the UE although the MAC transmitted messages to the UE equal to max retransmission
due to a timeout that occurs while waiting to receive RRCConnectionReestablishment when the initial UE message is transmitted to the UE and the MAC transmits messages to the UE as many times as the max retransmission, but HARQ ACK notification is not received from the UE.
RelActive_E ccbArqMaxR eTransmissi on
The cumulated number about established E-RABs when a call is released as a result of not receiving ARQ ACK notification from the UE although the RLC transmitted messages to the UE equal to max retransmission
This counter is cumulated about established E-RABs when a call is released as a result of not receiving ARQ ACK notification from the UE although the RLC transmitted messages to the UE equal to max retransmission.
Y
CC
event
int
0~2147 483647
-
-
RelActive_E ccbTmoutRr cConnection Reconfig
The cumulated number about established E-RABs when a call is released due to a timeout that has occurred since RRCConnectionReconfigurati onComplete is not received from the UE
This counter is cumulated about established E-RABs when a call is released due to a timeout that has occurred since RRCConnectionReconfigu rationComplete is not received from the UE.
Y
CC
event
int
0~2147 483647
-
-
RelActive_E ccbTmoutRr cConnection Reestablish
The cumulated number about established E-RABs when a call is released due to a timeout that has occurred
This counter is cumulated about established E-RABs when a call is released due to a timeout that has
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
270
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
since RRCConnectionReestablishmentComplete is not received from the UE
occurred since RRCConnectionReestablishmentComplete is not received from the UE.
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Collection Time (Success) Figure 194. Collection Time for E-RAB release UE
eNB
MME
S/GW
RRC_CONNECTED E-RAB Release Command Attempt
1
Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete Success
2
E-RAB Release Response
RRC_CONNECTED
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
271
Chapter 2 Counter Description
Collection Time (Failure) Figure 195. Collection Time for RelFailNbr_CpCcFail UE
EPC
eNB
MME
SGW
ERAB Release Command Application Restart ERAB Release Response
① RelFailNbr_CpCcFail
Figure 196. Collection Time for RelFailNbr_S1apSigFail UE
eNB
EPC MME
SGW
ERAB Release Command UE Context Release Command (or S1AP Reset) ERAB Release Response ① RelFailNbr_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
272
Chapter 2 Counter Description Figure 197. Collection Time for RelFailNbr_S1apCuFail UE
eNB
EPC MME
SGW
ERAB Release Command S1AP Cause ERAB Release Response ① RelFailNbr_S1apCuFail
Figure 198. Collection Time for RelActive UE
eNB
EPC MME
SGW
ERAB Release Command # of E-RAB BY Abnormal Operation In eNB ERAB Release Response ① RelActive
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
273
Chapter 2 Counter Description
Figure 199. Collection Time for RelFailNbr_CpCcInteraction UE
TeNB or Other RAT
EPC
SeNB
MME
SGW
Handover Request
Handover Request Acknowledge Rrc Connection Reconfiguration
X2 HO
ERAB Release Command
E-RAB Add fail ERAB Release Response
① RelFailNbr_CpCcInteraction
UE
TeNB or Other RAT
EPC
SeNB
MME
SGW
Handover Required Handover Request Handover Request Acknowledge Rrc Connection Reconfiguration
S1 HO
Handover Command ERAB Release Command E-RAB Add fail ERAB Release Response
① RelFailNbr_CpCcInteraction
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
274
Chapter 2 Counter Description Figure 200. Collection Time for RelActive_EccbRadioLinkFailure eNB ECCB
RLC
UE
MME
S/GW
RRC_CONNECTED HARQ ACK
X
Fail Message Timer InternalReestablishmentTimeToWait
RRCConnectionReestablishmentRequest
X RlcRleaseCnf about Erab of relActiveFlag =1
1
RelActive_EccbRadioLinkFailure
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
275
Chapter 2 Counter Description Figure 201. Collection Time for RelActive_EccbArqMaxReTransmission eNB ECCB
RLC
UE
MME
S/GW
RRC_CONNECTED ARQ ACK
X
Fail Message Timer InternalReestablishmentTimeToWait
RRCConnectionReestablishmentRequest
X RlcRleaseCnf about Erab of relActiveFlag =1
1
RelActive _EccbArqMaxReTransmission
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
276
Chapter 2 Counter Description Figure 202. Collection Time for RelActive_EccbTmoutRrcConnectionReconfig eNB UE
MME
ECCB
RLC
S/GW
RRC_CONNECTED RRCConnectionReconfiguration RRCConnectionReconfigurationComplete
X
1 RlcRleaseCnf about Erab of relActiveFlag =1
RelActive _EccbTmoutRrcConnectionReconfig
RRC_IDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
277
Chapter 2 Counter Description Figure 203. Collection Time for RelActive_EccbTmoutRrcConnectionReestablish eNB UE
MME
S/GW
ECCB
RLC
RRC_CONNECTED RRCConnectionReestablishmentRequest RRCConnectionReestablishment
Timer RRCConnectionReEstablish RRCConnectionReestablishmentComplete
X
1
RelActive _EccbTmoutRrcConnectionReestablish
RlcRleaseCnf about Erab of relActiveFlag =1
For E-RAB release statistics, when the E-RAB Release Request message is received from the MME, it is counted as Attempt; when the ERAB Release Response message is transmitted, it is counted as Success. A Failure is counted when the E-RAB Release procedure fails due to S1 MSG receiving, and the applicable cause value is recorded. Also, A Failure is counted when the procedure fails due to the ERAB Release Command or an internal timeout and failure, the applicable cause value is recorded.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
278
Chapter 2 Counter Description
E-RAB Session Time per Cell This section provides statistics on the in-session time of the UE. In-session is defined as valid if a data transmission took place during the last 100 ms; it collects the in-session time of the UE which had data transmissions with the PDSCH/PUSCH during the statistics period. (3GPP TS 32.425) Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
SessionTime UEAvg
ms
This counter defines in-sessions as events in which a data transfer has taken place in the last 100 msec of the collection interval. It collects the in-session times of UEs that transmit/receive data to/from the PDSCH/PUSCH during the collection interval.
This counter is cumulated by 1 when there is an UE that transmitted/received data to the PDSCH/PUSCH during the last 100 msec of the collection interval. This counter is calculated by cumulating the number of UEs that transmit PDSCH/PUSCH data at 100-msec intervals and then dividing the resulting value by 51.2 (5120/100 msec), as an average.
Y
SI
5.12 s
float
0~3.4*1 0^38
SessionTime UETot/Sessio nTimeUECnt
sum(SessionTimeUE Tot)/sum(SessionTi meUECnt)
SessionTime
ms
The cumulated count of
This counter is cumulated when SessionTimeUE is
Y
SI
5.12 s
float
0~3.4*1
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
279
Chapter 2 Counter Description Name
Unit
UETot SessionTime UECnt
count
Description
Trigger
SessionTimeUE
collected
The collection count of SessionTimeUEt
This counter is cumulated by 1 when SessionTimeUE is collected
Visible
Counter Type
Trigger Type
Data Type
-
SI
5.12 s
int
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
-
-
0^38 0~21474 83647
Collection Time Figure 204. Collection Time for SessionTimeUEAvg/Tot/Cnt In-session time of UE_G in Cell 0
3
In-session time of UE_F in Cell 0
In-session time of UE_C in Cell 0
2
In-session time of UE_E in Cell 0
In-session time of UE_B in Cell 0
1
Statistics Gathering Period In-session time of UE_D in Cell 0
In-session time of UE_A in Cell 0
Statistics Gathering Period
1
2
3
4
t
⓪ SessionTimeUE = SessionTimeUETot/SessionTimeUECnt ① SessionTimeUETot = In-session time of UE A + B + C in same cell
② SessionTimeUECnt
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
280
Chapter 2 Counter Description
E-RAB Session Time per QCI This section provides statistics on the in-session time per QCI. In-session is defined as valid if a data transmission took place during the last 100 ms; it collects the in-session time of the Bearer which had data transmissions with the PDSCH/PUSCH during the statistics period for each QCI. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
SessionTimeQ ciAvg
ms
This counter defines insessions as events in which a data transfer has taken place in the last 100 msec of the collection interval. It collects for each QCI the in-session times of bearers that transmit/receive data to/from the PDSCH/PUSCH
This counter is cumulated by 1 when, there is a bearer that transmitted/received data to the PDSCH/PUSCH during the last 100 msec of the collection interval per each QCI. This counter is calculated by cumulating the number of bearers that transmit PDSCH/PUSCH data at 100-msec intervals for each QCI and then dividing the cumulated number by 51.2 (5120/100 msec), as an average.
Y
SI
5.12 s
float
0~3.4*10 ^38
SessionTimeQ ciTot/SessionTi meQciCnt
sum(SessionTimeQ ciTot)/sum(Session TimeQciCnt)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
281
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
during the collection interval. SessionTimeQ ciTot
ms
The cumulated count of SessionTimeQCI
This counter is cumulated when SessionTimeQCI is collected
Y
SI
5.12 s
float
0~3.4*10 ^ 38
-
-
SessionTimeQ ciCnt
count
The collection count of SessionTimeQCI
This counter is cumulated by 1 when SessionTimeQCI is collected
-
SI
5.12 s
int
0~21474 83647
-
-
Collection Time Figure 205. Collection Time for SessionTimeQciAvg/Tot/Cnt
In-session time of ERAB G of QCI9
3
In-session time of ERAB F of QCI9
In-session time of ERAB C of QCI9
2
In-session time of ERAB E of QCI9
In-session time of ERAB B of QCI9
1
Statistics Gathering Period In-session time of ERAB D of QCI9
In-session time of ERAB A of QCI9
Statistics Gathering Period
1
2
3
4
t
⓪ SessionTimeQCI = SessionTimeQCITot/SessionTimeQCICnt ① SessionTimeQCITot = In-session time of E-RAB A + B + C in same QCI
② SessionTimeQCICnt
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
282
Chapter 2 Counter Description
Active E-RAB Number This section provides statistics on the E-RAB setup count. Collects statistics data for the average E-RAB setup count and the maximum E-RAB setup count for each cell. Index Name
Description
cNum
Cell Id
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrAvg
count
The average E-RAB count per unit time.
This counter is collected when ERAB counter per unit time is reported
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrTot/ UsageNbrCnt
sum(UsageNbrTot)/ sum(UsageNbrCnt)
UsageNbrMa x
count
The maximum ERAB count per unit time.
This counter is collected when ERAB counter per unit time is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrMax)
UsageNbrTot
count
The cumulated number of E-RAB count
This counter is collected when ERAB counter per unit time is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
UsageNbrCnt
count
The collection count fo UsageNbrAvg
This counter is collected when ERAB counter per unit time is reported
-
GAUGE
2s
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
283
Chapter 2 Counter Description
Collection Time Figure 206. Collection Time for UsageNbrAvgAvg/Max/Tot/Cnt # of E-RAB Statistics Gathering Period
A
C B
Statistics Gathering Period
E
F
. . .
5
6
1
D
t 1
2
3
4
UsageNbr = ② UsageNbrTot/③ UsageNbrCnt ① UsageNbrMax = C ② UsageNbrTot = A + B + C + D + E + F ⓪
③ UsageNbrCnt
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
284
Chapter 2 Counter Description
Active E-RAB Number per PLMN This section provides statistics on the average setup ERAB count and maximum setup ERAB count per PLMN and cell. Index Name
Description
cNum
Cell Id
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrPLM N0Avg
count
The average ERAB count per unit time in the PLMN0
This counter is collected when E-RAB counter per unit time in the PLMN0 is reported
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrPLMN0 Tot/UsageNbrPL MN0Cnt
sum(UsageNbrPLMN0 Tot)/sum(UsageNbrPL MN0Cnt)
UsageNbrPLM N0Max
count
The maximum E-RAB count per unit time in the PLMN0
This counter is collected when E-RAB counter per unit time in the PLMN0 is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrPLMN0 Max)
UsageNbrPLM N0Tot
count
The cumulated E-RAB count per unit time in the PLMN0
This counter is collected when E-RAB counter per unit time in the PLMN0 is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
285
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrPLM N0Cnt
count
The cumulated collection count of UsageNbrPLM N0Avg
This counter is collected when E-RAB counter per unit time in the PLMN0 is reported
-
GAUGE
2s
int
0~21474836 47
-
-
UsageNbrPLM N1Avg
count
The average ERAB count per unit time in the PLMN1
This counter is collected when E-RAB counter per unit time in the PLMN1 is reported
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrPLMN1 Tot/UsageNbrPL MN1Cnt
sum(UsageNbrPLMN1 Tot)/sum(UsageNbrPL MN1Cnt)
UsageNbrPLM N1Max
count
The maximum E-RAB count per unit time in the PLMN1
This counter is collected when E-RAB counter per unit time in the PLMN1 is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrPLMN1 Max)
UsageNbrPLM N1Tot
count
The cumulated E-RAB count per unit time in the PLMN1
This counter is collected when E-RAB counter per unit time in the PLMN1 is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
UsageNbrPLM N1Cnt
count
The cumulated collection count of UsageNbrPLM N1Avg
This counter is collected when E-RAB counter per unit time in the PLMN1 is reported
-
GAUGE
2s
int
0~21474836 47
-
-
UsageNbrPLM N2Avg
count
The average ERAB count per unit time in the
This counter is collected when E-RAB counter
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrPLMN2 Tot/UsageNbrPL MN2Cnt
sum(UsageNbrPLMN2 Tot)/sum(UsageNbrPL MN2Cnt)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
286
Chapter 2 Counter Description Name
Unit
Description
Trigger
PLMN2
per unit time in the PLMN2 is reported
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrPLM N2Max
count
The maximum E-RAB count per unit time in the PLMN2
This counter is collected when E-RAB counter per unit time in the PLMN2 is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrPLMN2 Max)
UsageNbrPLM N2Tot
count
The cumulated E-RAB count per unit time in the PLMN2
This counter is collected when E-RAB counter per unit time in the PLMN2 is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
UsageNbrPLM N2Cnt
count
The cumulated collection count of UsageNbrPLM N2Avg
This counter is collected when E-RAB counter per unit time in the PLMN2 is reported
-
GAUGE
2s
int
0~21474836 47
-
-
UsageNbrPLM N3Avg
count
The average ERAB count per unit time in the PLMN3
This counter is collected when E-RAB counter per unit time in the PLMN3 is reported
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrPLMN3 Tot/UsageNbrPL MN3Cnt
sum(UsageNbrPLMN3 Tot)/sum(UsageNbrPL MN3Cnt)
UsageNbrPLM N3Max
count
The maximum E-RAB count per unit time in the PLMN3
This counter is collected when E-RAB counter per unit time in the PLMN3 is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrPLMN3 Max)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
287
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrPLM N3Tot
count
The cumulated E-RAB count per unit time in the PLMN3
This counter is collected when E-RAB counter per unit time in the PLMN3 is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
UsageNbrPLM N3Cnt
count
The cumulated collection count of UsageNbrPLM N3Avg
This counter is collected when E-RAB counter per unit time in the PLMN3 is reported
-
GAUGE
2s
int
0~21474836 47
-
-
UsageNbrPLM N4Avg
count
The average ERAB count per unit time in the PLMN4
This counter is collected when E-RAB counter per unit time in the PLMN4 is reported
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrPLMN4 Tot/UsageNbrPL MN4Cnt
sum(UsageNbrPLMN4 Tot)/sum(UsageNbrPL MN4Cnt)
UsageNbrPLM N4Max
count
The maximum E-RAB count per unit time in the PLMN4
This counter is collected when E-RAB counter per unit time in the PLMN4 is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrPLMN4 Max)
UsageNbrPLM N4Tot
count
The cumulated E-RAB count per unit time in the PLMN4
This counter is collected when E-RAB counter per unit time in the PLMN4 is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
UsageNbrPLM N4Cnt
count
The cumulated collection count of
This counter is collected when E-RAB counter
-
GAUGE
2s
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
288
Chapter 2 Counter Description Name
Unit
Description
Trigger
UsageNbrPLM N4Avg
per unit time in the PLMN4 is reported
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrPLM N5Avg
count
The average ERAB count per unit time in the PLMN5
This counter is collected when E-RAB counter per unit time in the PLMN5 is reported
Y
GAUGE
2s
float
0~3.4*10^38
UsageNbrPLMN5 Tot/UsageNbrPL MN5Cnt
sum(UsageNbrPLMN5 Tot)/sum(UsageNbrPL MN5Cnt)
UsageNbrPLM N5Max
count
The maximum E-RAB count per unit time in the PLMN5
This counter is collected when E-RAB counter per unit time in the PLMN5 is reported
Y
GAUGE
2s
float
0~3.4*10^38
-
max(UsageNbrPLMN5 Max)
UsageNbrPLM N5Tot
count
The cumulated E-RAB count per unit time in the PLMN5
This counter is collected when E-RAB counter per unit time in the PLMN5 is reported
-
GAUGE
2s
float
0~3.4*10^38
-
-
UsageNbrPLM N5Cnt
count
The cumulated collection count of UsageNbrPLM N5Avg
This counter is collected when E-RAB counter per unit time in the PLMN5 is reported
-
GAUGE
2s
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
289
Chapter 2 Counter Description
Collection Time Figure 207. Collection Time for UsageNbrPLMN0~5Avg/Max/Tot/Cnt PLMN 5 # of E-RAB PLMN 4 Statistics Gathering Period Statistics Gathering Period # of E-RAB PLMN 3 Statistics Gathering Period Statistics Gathering Period # of E-RAB PLMN 2 Statistics Gathering Period Statistics Gathering Period # of E-RAB PLMN 1 Statistics Gathering Period Statistics Gathering Period . #Cof E-RAB A PLMN 0 E Statistics Statistics Gathering Period B F Gathering Period . . #Cof E-RAB A A
1
D
B
B
C
D
5C
. Period E Statistics F Gathering . . . E F .
Statistics Gathering Period
. 4 6 2 3A 1 . D E B F . C . 5 D 6 1 2 3A 4 1 E UsageNbr ⓪ = . ②. UsageNbrTot /③ B F C . 5 D 6 1 2 3A 4 1 E UsageNbr UsageNbrCnt ⓪ = . ②. UsageNbrTot / ③ B F 4 5 D① 6UsageNbrMax 1 2 3 1=C UsageNbrCnt ⓪ UsageNbr = . ② UsageNbrTot / ③
t t t t
t 4 6 1 2 3 1= C t ②5 UsageNbrTot = A+B+C+D+E+F ① UsageNbrMax UsageNbrCnt ⓪ UsageNbr = ② UsageNbrTot / ③ ③ UsageNbrCnt 4 5 6 1 2 3 1 ② UsageNbrTot = A+B+C+D+E+F ① UsageNbrMax =C = UsageNbrCnt ⓪ UsageNbr ② UsageNbrTot / ③ ③ UsageNbrCnt ② UsageNbrTot = A+B+C+D+E+F ① UsageNbrMax =C UsageNbrCnt ③ UsageNbrCnt UsageNbr ② UsageNbrTot = A+B+C+D+E+F ①⓪ UsageNbrMax = C= ② UsageNbrTot/③ UsageNbrCnt ③ UsageNbrCnt UsageNbrMax =C ②① UsageNbrTot = A+B+C+D+E+F ③ UsageNbrCnt ② UsageNbrTot = A + B + C + D + E + F ③ UsageNbrCnt
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
290
Chapter 2 Counter Description
E-RAB QCI per-PLMN rejected This section provides statistics on the E-RAB QCI per PLMN that is rejected. If the requested QCI is rejected because it is not allowed for a PLMN, it is collected. A PLMN ID consists of MCC and MNC under the condition that plmnIndex is 0 in PLDEnbPlmnInfo, and it may be viewed with RTRV-ENBPLMN-INF. Index Name
Description
cNum
Cell Id
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PLMN0QC IReject
count
The cumulated number when the requested QCI is rejected because it is not allowed for the PLMN0
This counter is cumulated when QCI is rejected for ERAB setup because it is not allowed in the PLMN0
Y
CC
event
int
0~21474 83647
-
-
PLMN1QC IReject
count
The cumulated number when the requested QCI is rejected because it is not allowed for the PLMN1
This counter is cumulated when QCI is rejected for ERAB setup because it is not allowed in the PLMN1
Y
CC
event
int
0~21474 83647
-
-
PLMN2QC IReject
count
The cumulated number when the requested QCI is rejected because it is not allowed for the PLMN2
This counter is cumulated when QCI is rejected for ERAB setup because it is not allowed in the PLMN2
Y
CC
event
int
0~21474 83647
-
-
PLMN3QC IReject
count
The cumulated number when the requested QCI is rejected because it is not
This counter is cumulated when QCI is rejected for ERAB setup because it is not
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
291
Chapter 2 Counter Description Name
Unit
PLMN4QC IReject
count
PLMN5QC IReject
count
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
allowed for the PLMN3
allowed in the PLMN3
The cumulated number when the requested QCI is rejected because it is not allowed for the PLMN4
This counter is cumulated when QCI is rejected for ERAB setup because it is not allowed in the PLMN4
Y
CC
event
int
0~21474 83647
-
-
The cumulated number when the requested QCI is rejected because it is not allowed for the PLMN5
This counter is cumulated when QCI is rejected for ERAB setup because it is not allowed in the PLMN5
Y
CC
event
int
0~21474 83647
-
-
Collection Time Figure 208. Collection Time for PLMN0~5QCIReject EPC
eNB
MME
Initial UE Context Setup or E-RAB Setup Request or E-RAB Setup Modify(Add) ...for QCI X(PLMN Y) QCI X Is not allowed (PLMN Y)
Reject for QCI X (PLMN Y)
SGW
⓪ PLMN0QCIReject
① ② ③ ④ ⑤
PLMN1QCIReject PLMN2QCIReject PLMN3QCIReject PLMN4QCIReject PLMN5QCIReject
ⓞ, ①, ②, ③, ④, ⑤
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
292
Chapter 2 Counter Description
HO EUTRAN The statistics on handovers are collected for intra LTE handover and inter RAT handover respectively. Intra LTE handover includes intra eNB, inter eNB S1, and inter eNB X2 handovers. Inter RAT handover includes inter RAT optimized HRPD and inter RAT UTRAN handovers. Intra-LTE handover statistics are based on the source and target cells, which are collected through the respective source and target eNBs. Inter-RAT handover statistics are based on the eNB’s served cells. Intra eNB Handover This section provides statistics data for handovers between cells within the eNB. Intra eNB handover is performed when the UE moves between the cells that belong to the same eNB. The following figure illustrates this procedure. Figure 209. Intra-eNB HandoverStatistics processing UE
Source cell 1) MeasurementReport
3) RRCConnection-Reconfiguration (mobilityControlinfo)
HO success
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Target cell
HO attempt 2) Target Cell Preparation HO preparation
4) RRCConnectionReconfigurationComplete
293
Chapter 2 Counter Description
Steps
Description
1)
Intra eNB handover is determined based on the measurement report.
2)
New RLC, MAC and PHY configurations are set for the target cell.
3)
When the resource setup is completed in the target cell, the RRC Connection Reconfiguration message is transmitted to instruct the UE to perform handover.
4)
The RRC Connection Reconfiguration Complete message is received to complete the intra handover successfully.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
294
Chapter 2 Counter Description
X2 Handover When the UE moves between cells of different eNBs that belong to the same MME group, handover is performed via the X2 interface. Upon performing the X2 handover, the source provides the statistics on outgoing handover; and the target provides statistics for incoming. The procedure of collecting Attempt, Preparation, and Success statistics is shown in the following figure. Figure 210. X2 Based Handover Statistics processing UE
Source eNB
MME
Target eNB
Downlink data
EPC
S-GW
Downlink data
1) MeasurementReport 4) RRCConnectionReconfiguration (mobilityControlinfo)
2) HANDOVER REQUEST
HO attempt
3) HANDOVER REQUEST ACKNOWLEDGE HO Preparation
5) SN STATUS TRANSFER Data forwarding 6) Synchronization/UL allocation and timing advance 7) RRCConnectionReconfigurationComplete Forwarded data Uplink data
Uplink data 8) PATH SWITCH REQUEST
9) Modify Bearer Request
End marker Forwarded data End marker
12) UE CONTEXT RELEASE Down/Uplink data
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink data 11) PATH SWITCH REQUEST ACKNOWLEDGE
10) Modify Bearer Response
HO Success Down/Uplink data
295
Chapter 2 Counter Description
Step
Description
1)
The UE transmits the MeasurementReport message according to the system information, standards and rules. The source eNB determines whether to perform the UE handover based on the MeasurementReport message and the radio resource management information.
2)
The source eNB sends the target eNB a HANDOVER REQUEST message containing the information required for handover. The target eNB can perform management control in accordance with the E-RAB QoS information received.
3)-4)
The target eNB creates the RRCConnectionReconfiguration message which contains the mobileControlInfo IE for preparing and executing the handover. The target eNB transmits RRCConnectionReconfiguration to the source eNB, which is encapsulated in the HANDOVER REQUEST ACKNOWLEDGE message. The source eNB transmits the RRCConnectionReconfiguration message and the necessary parameters to the UE to command it to perform the handover.
5)
To transmit the uplink PDCP SN receiver status and the downlink PDCP SN transmitter status of the E-RABs of which the PDCP status must be preserved, the source eNB transmits the SN STATUS TRANSFER message to the target eNB.
6)
After receiving the RRCConnectionReconfiguration message that encapsulates the mobileControlInfo IE, the UE performs synchronization with the target eNB and accesses the target cell via the Random Access CHannel (RACH). The target eNB responds with UL allocation and a timing advance value.
7)
After having connected to the target cell successfully, the UE notifies the target eNB that the Handover procedure has been completed using an RRCConnectionReconfigurationComplete message.
8)
The target eNB, using the PATH SWITCH REQUEST message, notifies the MME that the UE has changed the cell.
9)-10)
The MME sends the Modify Bearer Request message to the S-GW. The S-GW changes the downlink data path into the target eNB. The S-GW transmits at least one ‘end marker’ to the source eNB through the previous path, and releases the user plane resources for the source eNB. The S-GW transmits a Modify Bearer Response message to the MME.
11)
The MME transmits the PATH SWITCH REQUEST ACKNOWLEDGE message to acknowledge the PATH SWITCH REQUEST message
12)
The target eNB sends the UE CONTEXT RELEASE message to the source eNB to notify the handover has succeeded and to make the source eNB release its resources. If the source eNB receives the UE CONTEXT RELEASE message, it releases the radio resources and the control plane resources related to the UE context.
S1 Handover Generally, when two eNBs belong to the same MME group, handover is performed via the X2 interface, and if two eNBs belong to different MME groups, handover is performed via the S1 interface. However, if they belong to the same MME, but there is no X2 interface between the two eNBs or there is X2 link failure, handover is performed via the S1 interface. Upon performing the S1 handover, the source provides the statistics on outgoing handover; and the target provides statistics for the incoming handover. Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
296
Chapter 2 Counter Description
The procedure of collecting Attempt, Preparation, and Success statistics is shown below.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
297
Chapter 2 Counter Description Figure 211. S1 Handover Procedure UE
Source eNB
MME
Target eNB
Downlink/Uplink data
EPC
S-GW
Downlink/Uplink data 1) Decision to trigger a relocation via S1 2) HANDOVER REQUEST
HO attempt HO attempt
3) HANDOVER REQUEST 4) HANDOVER REQUEST ACKNOWLEDGE
HO Preparation HO Preparation
8) RRCConnectionReconfiguration (mobilityControlinfo)
5) Create Indirect Data Forwarding Tunnel Request 6) Create Indirect Data Forwarding Tunnel Response
7) HANDOVER COMMAND 9) eNB STATUS TRANSFER (1) Direct data forwarding
10) MME STATUS TRANSFER (2) Indirect data forwarding Indirect data forwarding
11) Detach from old cell/Synchronize to new cell 12) RRCConnectionReconfigurationComplete Forwarded data Uplink data
Uplink data HO Success
13) HANDOVER NOTIFY End marker
14) Modify Bearer Request 15) Modify Bearer Response
Forwarded data End marker
Downlink data
Downlink data 16) Tracking Area Update procedure HO Success
17) UE CONTEXT RELEASE COMMAND 18) UE CONTEXT RELEASE COMPLETE
19) Delete Indirect Data Forwarding Tunnel Request 20) Delete Indirect Data Forwarding Tunnel Response
Downlink/Uplink data
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink/Uplink data
298
Chapter 2 Counter Description
Step
Description
1)
The source eNB determines whether to perform S1-based handover into the target eNB. The source eNB can make this decision when there is no X2 connection to the target or when an error is notified by the target eNB after an X2-based handover has failed, or based on the information the source eNB has obtained dynamically.
2)
The source eNB transmits the HANDOVER REQUIRED message to the MME. The source eNB notifies the target eNB which bearer is used for data forwarding and whether forwarding can be made directly from the source eNB to the target eNB.
3)-4)
The MME transmits the HANDOVER REQUEST message to the target eNB. This message makes the target eNB create a UE context containing the bearer-related information and the security context. The target eNB transmits the HANDOVER REQUEST ACKNOWLEDGE message to the MME.
5)-6)
If indirect forwarding is used, the MME sends the Create Indirect Data Forwarding Tunnel Request message to the S-GW. The S-GW replies the MME with the Create Indirect Data Forwarding Tunnel Response message.
7)-8)
The MME sends the HANDOVER COMMAND message to the source eNB. The source eNB creates the RRCConnectionReconfiguration message using the Target to Source Transparent Container IE encapsulated in the HANDOVER COMMAND message and then transmits it to the UE.
9)-10)
To transmit the PDCP and HFN status of the E-RABs of which the PDCP status must be preserved, the source eNB transmits the eNB/MME STATUS TRANSFER message to the target eNB via the MME. The source eNB must start forwarding the downlink data to the target eNB through the bearer which was determined to be used for data forwarding. This can be either direct or indirect forwarding.
11)
The UE performs synchronization with the target eNB and connects to the target cell via a RACH. The target eNB responds with UL allocation and a timing advance value.
12)
After having synchronized with the target cell, the UE notifies the target eNB that the Handover procedure has been completed using the RRCConnectionReconfiguration Complete message. The downlink packets forwarded from the source eNB can be transmitted to the UE. The uplink packets can also be transmitted from the UE to the S-GW via the target eNB.
13)
The target eNB sends the HANDOVER NOTIFY message to the MME. The MME starts the timer which tells when the resources of the source eNB and the temporary resources used by the S-GW for indirect forwarding will be released.
14)
The MME transmits the Modify Bearer Request message for each PDN connection to the S-GW. Downlink packets are transmitted from the S-GW to the target eNB immediately.
15)
The S-GW transmits a Modify Bearer Response message to the MME. As soon as the target eNB changes the path to help packet reordering, the SGW transmits at least one ‘end marker’ packet to the source eNB through the previous path.
16)
If any of the conditions listed in section 5.3.3.0 of TS 23.401 (6) are met, the UE starts the Tracking Area Update procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
299
Chapter 2 Counter Description Step
Description
17)-18)
When the timer started at step 13) expires, the MME sends the UE CONTEXT RELEASE COMMAND message to the source eNB. The source eNB releases the resources related to the UE and replies with the UE CONTEXT RELEASE COMPLETE message.
19)-20)
If indirect forwarding has been used, when the timer started at Step 13) expires the MME transmits the Delete Indirect Data Forwarding Tunnel Request message to the S-GW. This message gets the S-GW to release the temporary resources allocated for indirect forwarding at Step 5). The S-GW responds to the MME with the Delete Indirect Data Forwarding Tunnel Response message.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
300
Chapter 2 Counter Description
Intra-eNB Handover This section provides statistics on the handovers between cells within the eNB. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbAtt
count
The cumulated number when intra HO is judged in the handover decision after a measurement report message is received from the UE. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
This counter is cumulated when intra HO is judged in the handover decision after a measurement report message is received from the UE. The statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Succ
count
The cumulated number when the RRC connection
This counter is cumulated when handover preparation is completed after receiving
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
301
Chapter 2 Counter Description Name
Unit
Description
Trigger
reconfiguration message is transmitted to the UE since preparation is completed for handover to the target cell between the inner blocks when intra HO is judged in the handover decision after a measurement report message is received from the UE.
a response message for resource allocation of the target cell between the internal blocks when intra HO is judged in the handover decision after a measurement report message is received from the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbSucc
count
The cumulated number when the target cell normally receives the RRC connection reconfiguration complete message from the UE by performing intra HO.
This counter is cumulated when the target cell normally receives the RRC connection reconfiguration complete message from the UE by performing intra HO.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_CpCcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the intra HO preparation procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the intra HO preparation procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_CpCcFai l
count
The cumulated number when preparation fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource
This counter is cumulated when the eNB releases a call due to ECMB reset during Intra HO preparation procedure.
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
302
Chapter 2 Counter Description Name
IntraEnbPrep Fail_UpMacF ail
Unit
count
Description
Trigger
allocation failure during the intra HO preparation procedure.
This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra HO preparation Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the intra HO preparation procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Intra HO preparation procedure
The cumulated number when preparation fails due to an audit mismatch between the ECCB and MAC or receiving Fail as a response message after transmitting the resource information of the target cell to the MAC
This counter is cumulated when Fail is received as a response message after the resource information of the target cell is transmitted to the MAC block during the intra HO preparation procedure. This counter is cumulated
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
303
Chapter 2 Counter Description Name
Unit
Description during the intra HO preparation procedure.
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra HO preparation procedure.
IntraEnbPrep Fail_UpRlcFa il
count
The cumulated number when preparation fails due to an audit mismatch between the ECCB and RLC or receiving Fail as a response message after transmitting the resource information of the target cell to the MAC during the intra HO preparation procedure.
This counter is cumulated when Fail is received as a response message after the resource information of the target cell is transmitted to the RLC block during the intra HO preparation procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the intra HO preparation procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_RrcSigF ail
count
This counter is not collected in the system
None
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_CpBhCa cFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth
This counter is cumulated preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
304
Chapter 2 Counter Description Name
Unit
Description
Trigger
operation during the intra HO preparation procedure.
the intra HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbPrep Fail_CpCapa CacFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the intra HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the intra HO preparation procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_CpQosC acFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the intra HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the intra HO preparation procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_S1apCu Fail
count
The cumulated number when preparation fails due to S1AP specification cause during the intra handover preparation.
This counter is cumulated when preparation fails due to S1AP specification cause during the intra handover preparation.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbPrep Fail_S1apLin kFail
count
The cumulated number when preparation fails since the S1AP link status is changed to 'Out of Service' during the intra HO preparation procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Intra HO
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
305
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
preparation procedure This counter is cumulated when the eNB releases the call due to an SCTB reset during Intra HO preparation procedure IntraEnbPrep Fail_S1apSig Fail
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Intra HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Intra HO preparation procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbFail_ CpCcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the intra HO execution procedure.
This counter is cumulated when a call is released during the intra HO execution procedure due to a timeout that occurs when a response is not received during the forward path setup procedure with the GTP block. This counter is cumulated when a call is released
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
306
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147 483647
-
-
during the intra HO execution procedure due to a timeout that occurs when a response is not received during the reestablish control procedure with the RLC block. This counter is cumulated when a call is released during the intra HO execution procedure due to a timeout that occurs when a response is not received during the buffer flush procedure with the PDCP. IntraEnbFail_ CpCcFail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra HO execution procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB releases a call due to ECMB reset during Intra HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra HO execution Procedure This counter is cumulated when the eNB releases a
307
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra HO execution Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the intra HO execution procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Intra HO execution procedure IntraEnbFail_ UpGtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the intra HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the intra HO execution procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbFail_ UpMacFail
count
The cumulated number when execution fails since Fail is received as a response message
This counter is cumulated when execution fails since Fail is received as a response message from
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
308
Chapter 2 Counter Description Name
Unit
Description
Trigger
from the MAC block or an audit mismatch occurs with the MAC block during the intra HO execution procedure.
the MAC block during the intra HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbFail_ UpRlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the MAC block during the intra HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the intra HO execution procedure. This counter is cumulated when a call is released since a mismatch with the UE occurs between the ECCB and RLC when an audit of the UE information is executed during the intra HO execution procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbFail_ RrcHcTo
count
The cumulated number when a call is released due to a timeout that has occurred since an RRCConnectionComplet e message is not
This counter is cumulated when timeout occurs since RRCConnectionComplete is not received from the UE during the intra HO
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
309
Chapter 2 Counter Description Name
Unit
Description
Trigger
received from the UE or a response message is not received from the inner blocks (PDCP, RLC, MAC) during the intra HO execution procedure.
execution procedure. This counter is cumulated when a call is released due to a timeout that occurs since a response message is not received from the inner blocks (PDCP, RLC, MAC) during the intra HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbFail_ RrcSigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~2147 483647
-
-
IntraEnbFail_ S1apCuFail
count
The cumulated number when execution fails since a S1AP specification cause occurs during the intra HO execution procedure.
This counter is cumulated when execution fails since a S1AP specification cause occurs during the intra HO execution procedure.
Y
CC
event
int
0~2147 483647
-
-
IntraEnbFail_ S1apLinkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Intra HO execution procedure This counter is cumulated when the eNB releases the call due to an SCTB reset during Intra HO execution procedure
Y
CC
event
int
0~2147 483647
-
-
IntraEnbFail_ S1apSigFail
count
The cumulated number when execution fails
This counter is cumulated when the eNB releases
Y
CC
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
310
Chapter 2 Counter Description Name
Unit
Description
Trigger
since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the intra HO execution procedure.
the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Intra HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Intra HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbCnt
count
The cumulated number when intra HO is judged in the handover decision after a measurement report message is received from the UE.
This counter is cumulated when intra HO is judged in the handover decision after a measurement report message is received from the UE.
-
CC
event
int
0~2147 483647
-
-
IntraEnbNbr Cid
tcID
The tcID of which collection is requested
none
-
OW
event
int
0~2147 483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
311
Chapter 2 Counter Description
Collection Time (Success) Figure 212. Collection Time for Intra eNB Handover UE
eNB UE moves to Intra eNB Cell Measurement Report
Rrc Connection Reconfiguration
Attempt
1
HO Decision
Prepare
2
Target Cell Preparation
Success
3
Internal Path Switch
Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
312
Chapter 2 Counter Description
Collection Time (Failure) Figure 213. Collection Time for IntraEnbPrepFail_CpCcTo eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision Target Cell Preparation
Prepare
2
Resource Setup
X
Timer Internal Resource Setup Failure - IntraEnbPrepFail_CpCcTo
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
313
Chapter 2 Counter Description
Figure 214. Collection Time for IntraEnbPrepFail_CpCcFail (1) eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2 ECMB reset Failure - IntraEnbPrepFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
314
Chapter 2 Counter Description
Figure 215. Collection Time for IntraEnbPrepFail_CpCcFail (2) eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2 Cell disabled Failure - IntraEnbPrepFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
315
Chapter 2 Counter Description
Figure 216. Collection Time for IntraEnbPrepFail_CpCcFail (3) eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC Failure - IntraEnbPrepFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
316
Chapter 2 Counter Description
Figure 217. Collection Time for IntraEnbPrepFail_CpCcFail (4) eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Target cell resource allocation Failure Prepare
2
Resource Setup
X Failure - IntraEnbPrepFail_CpCcFail
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
317
Chapter 2 Counter Description Figure 218. Collection Time for IntraEnbPrepFail_UpMacFail (1) eNB Source Cell
UE
Target Cell (MAC)
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2
Fail Message Failure - IntraEnbPrepFail_UpMacFail
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
318
Chapter 2 Counter Description Figure 219. Collection Time for IntraEnbPrepFail_UpMacFail (2) eNB Source Cell
UE
Target Cell (MAC)
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup
Prepare
2
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. Failure - IntraEnbPrepFail_UpMacFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
319
Chapter 2 Counter Description Figure 220. Collection Time for IntraEnbPrepFail_UpRlcFail (1) eNB Source Cell
UE
Target Cell (RLC)
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2
Fail Message Failure - IntraEnbPrepFail_UpRlcFail
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
320
Chapter 2 Counter Description Figure 221. Collection Time for IntraEnbPrepFail_UpRlcFail (2) eNB Source Cell
UE
Target Cell (RLC)
UE moves to Intra eNB Cell Measurement Report Attempt
1
HO Decision Target Cell Preparation Resource Setup
Prepare
2 A mismatch of UE information occurred in the execution of audit between the ECCB and RLC. Failure - IntraEnbPrepFail_UpRlcFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
321
Chapter 2 Counter Description Figure 222. Collection Time for IntraEnbPrepFail_CpBhCacFail eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
2
CAC based on Backhaul Bandwidth Fail Failure - IntraEnbPrepFail_CpBhCacFail Resource Setup
X
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
322
Chapter 2 Counter Description Figure 223. Collection Time for IntraEnbPrepFail_CpCapaCacFail eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
2
CAC based on Call Count per Cell Fail or CAC based on DRB Count per Cell Fail Failure - IntraEnbPrepFail_CpCapaCacFail Resource Setup
X
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
323
Chapter 2 Counter Description Figure 224. Collection Time for IntraEnbPrepFail_CpQosCacFail eNB Source Cell
UE
Target Cell
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation CAC based on QoS Fail Prepare
2
Failure - IntraEnbPrepFail_CpQosCacFail Resource Setup
X
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
324
Chapter 2 Counter Description Figure 225. Collection Time for IntraEnbPrepFail_S1apCuFail eNB Source Cell
UE
Target Cell
MME
S/GW
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2 S1AP UE CONTEXT RELEASE COMMAND Failure - IntraEnbPrepFail_S1apCuFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
325
Chapter 2 Counter Description Figure 226. Collection Time for IntraEnbPrepFail_S1apLinkFail (1) eNB Source Cell
UE
Target Cell
MME
S/GW
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision Target Cell Preparation Resource Setup
Prepare
2
S1AP Link is Out Of Service Status
X
Failure - IntraEnbPrepFail_S1apLinkFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
326
Chapter 2 Counter Description Figure 227. Collection Time for IntraEnbPrepFail_S1apLinkFail (2) eNB Source Cell
UE
Target Cell
MME
S/GW
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2 SCTB reset Failure - IntraEnbPrepFail_S1apLinkFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
327
Chapter 2 Counter Description Figure 228. Collection Time for IntraEnbPrepFail_S1apSigFail (1) eNB Source Cell
UE
Target Cell
MME
S/GW
UE moves to Intra eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Resource Setup Prepare
2
S1AP UE CONTEXT RELEASE COMMAND Failure - IntraEnbPrepFail_S1apSigFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
328
Chapter 2 Counter Description Figure 229. Collection Time for IntraEnbPrepFail_S1apSigFail (2) eNB Source Cell
UE
Target Cell
MME
S/GW
UE moves to Intra eNB Cell
Measurement Report
1
Attempt
HO Decision
Target Cell Preparation Resource Setup Prepare
2
RESET Failure - IntraEnbPrepFail_S1apSigFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
329
Chapter 2 Counter Description Figure 230. Collection Time for IntraEnbFail_CpCcTo eNB UE
Source Cell (PDCP/RLC)
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
Resource Setup
2
Rrc Connection Reconfiguration Execution
3
Re-establish control Success Message
X
Timer Internal Reestablish Control
Failure - IntraEnbPrepFail_CpCcTo
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
330
Chapter 2 Counter Description Figure 231. Collection Time for IntraEnbFail_CpCcFail (1) eNB UE
Source Cell
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 ECMB reset Failure - IntraEnbFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
331
Chapter 2 Counter Description Figure 232. Collection Time for IntraEnbFail_CpCcFail (2) eNB UE
Source Cell
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 Cell disabled Failure - IntraEnbFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
332
Chapter 2 Counter Description Figure 233. Collection Time for IntraEnbFail_CpCcFail (3) eNB UE
Source Cell
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision Target Cell Preparation
Prepare
2
Resource Setup
Rrc Connection Reconfiguration Re-establish control Execution
3
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC Failure - IntraEnbFail_CpCcFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
333
Chapter 2 Counter Description Figure 234. Collection Time for IntraEnbFail_UpMacFail eNB UE
Source Cell (PDCP/RLC)
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. Failure - IntraEnbFail_UpMacFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
334
Chapter 2 Counter Description Figure 235. Collection Time for IntraEnbFail_UpRlcFail (1) eNB UE
Source Cell (RLC)
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3
Fail Message Failure - IntraEnbFail_UpRlcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
335
Chapter 2 Counter Description Figure 236. Collection Time for IntraEnbFail_UpRlcFail (2) eNB UE
Source Cell (RLC)
ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation
Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 A mismatch of UE information occurred in the execution of audit between the ECCB and RLC. Failure - IntraEnbFail_UpRlcFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
336
Chapter 2 Counter Description Figure 237. Collection Time for IntraEnbFail_RrcHcTo (1) eNB UE
ECCB
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
Prepare
1
HO Decision Target Cell Preparation
2
Resource Setup
Rrc Connection Reconfiguration Re-establish control Execution
3
Timer rrcConnection Reconfig Rrc Connection Reconfiguration Complete
X
Failure - IntraEnbFail_RrcHcTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
337
Chapter 2 Counter Description Figure 238. Collection Time for IntraEnbFail_RrcHcTo (2) eNB UE
ECCB
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report
Attempt
Prepare
1
HO Decision Target Cell Preparation
2
Resource Setup
Rrc Connection Reconfiguration Re-establish control Execution
3
Timer rrcConnection Reconfig Rrc Connection Reconfiguration Complete Success Message
X
Failure - IntraEnbFail_RrcHcTo
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
338
Chapter 2 Counter Description Figure 239. Collection Time for IntraEnbFail_S1apCuFail eNB Source Cell
UE
ECCB
Target Cell
MME
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 S1AP UE CONTEXT RELEASE COMMAND Failure - IntraEnbFail_RrcHcTo
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
339
Chapter 2 Counter Description Figure 240. Collection Time for IntraEnbFail_S1apLinkFail (1) eNB Source Cell
UE
ECCB
Target Cell
MME
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 S1AP Link is Out Of Service Status
X Failure - IntraEnbFail_S1apLinkFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
340
Chapter 2 Counter Description Figure 241. Collection Time for IntraEnbFail_S1apLinkFail (2) eNB Source Cell
UE
ECCB
Target Cell
MME
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 SCTB reset Failure - IntraEnbFail_S1apLinkFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
341
Chapter 2 Counter Description Figure 242. Collection Time for IntraEnbFail_S1apSigFail (1) eNB Source Cell
UE
ECCB
Target Cell
MME
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3
S1AP UE CONTEXT RELEASE COMMAND Failure - IntraEnbFail_S1apLinkFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
342
Chapter 2 Counter Description Figure 243. Collection Time for IntraEnbFail_S1apSigFail (2) eNB Source Cell
UE
ECCB
Target Cell
MME
UE moves to Intra eNB Cell Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Prepare
Resource Setup
2
Rrc Connection Reconfiguration Re-establish control Execution
3 RESET Failure -IntraEnbFail_S1apLinkFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
343
Chapter 2 Counter Description
For intra-handover statistics, Attempt is counted when an intra-handover is decided after the Measurement Report message arrival, and Prepare is counted when the intra-handover preparation is complete and at the time of transmitting the RRC Connection Reconfiguration message to the UE. Success is counted when the target cell successfully receives the RRC Connection Reconfiguration Complete message from the UE. When the procedure from 1 to 2 fails, it is counted as Prepare Fail, returning the cause value. When the procedure from 2 to 3 fails, it is counted as Intra Fail, returning the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
344
Chapter 2 Counter Description
X2 Out Handover This section provides statistics on the X2 handover between eNBs in reference with the source eNB for each cell. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2OutAtt
count
The cumulated number when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
This counter is cumulated when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutPr epSucc
count
The cumulated number when a RRC Connection Reconfiguration message
This counter is cumulated when the time to transmit the
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
345
Chapter 2 Counter Description Name
Unit
Description
Trigger
is transmitted to the UE since a HandoverRequestAcknowl edge message is received from the target eNB after a HandoverRequest message is transmitted to the target eNB due to inter X2 HO being judged in the HO decision after a MeasurementReport message is received from the UE.
RRC Connection Reconfiguration message is completed after HandoverRequest is transmitted to the target eNB and HandoverRequestAckn owledge is received from the target eNB when inter X2 HO is judged in the HO decision after the MeasurementReport message is received from the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2OutSu cc
count
The cumulated number when an UE context release command is normally received by the source eNB when the target eNB receives a RRC connection reconfiguration complete message from the UE after the source eNB transmits a RRCConnectionReconfigur ation message to the UE through inter X2 HO execution.
This counter is cumulated when an UE context release command is normally received by the source eNB when the target eNB receives a RRC connection reconfiguration complete message from the UE after the source eNB transmits a RRCConnectionReconf iguration message to the UE through inter X2 HO execution.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutPr epFail_CpCc Fail
count
The cumulated number when preparation fails due to a reset notification (eNB
This counter is cumulated when the eNB releases a call
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
346
Chapter 2 Counter Description Name
Unit
Description
Trigger
failure or block restart) from ECMB or ECCB resource allocation failure during the inter X2 HO preparation procedure.
due to ECMB reset during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Inter X2 HO preparation Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter HO preparation procedure. This counter is cumulated when a call release due to
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
347
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
failure of ECCB resource allocation during Inter X2 HO preparation procedure InterX2OutPr epFail_S1ap LinkFail
count
The cumulated number when preparation fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutPr epFail_S1ap SigFail
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO preparation
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
348
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO preparation procedure. InterX2OutPr epFail_X2ap CuFail
count
The cumulated number when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutPr epFail_X2ap LinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2OutPr epFail_X2ap RpTo
count
The cumulated number when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
349
Chapter 2 Counter Description Name
Unit
Description
Trigger
procedure.
inter X2 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2OutPr epFail_X2ap SigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_CpCcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_CpCcFail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
350
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RTRV-CELL-STS) is changed to disabled during Inter X2 HO execution Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter X2 HO execution procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO execution procedure InterX2OutFa il_UpGtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_UpMacFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
351
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2OutFa il_UpPdcpFai l
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_UpRlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter X2 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_RrcSigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_S1apCuFai l
count
The cumulated number when execution fails since a S1AP specification cause
This counter is cumulated when a call is released due to the
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
352
Chapter 2 Counter Description Name
Unit
Description
Trigger
occurs during the inter X2 HO execution procedure.
S1AP specification cause during the inter X2 handover execution.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2OutFa il_S1apLinkF ail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO execution procedure This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO execution procedure
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_S1apSigFa il
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases the call
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
353
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
as a result of receiving an S1AP RESET message from MME during Inter X2 HO execution procedure. InterX2OutFa il_X2apCuFai l
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_X2apLinkF ail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2OutFa il_X2apRoTo
count
The cumulated number when a timeout occurs since the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE during the Inter X2 HO execution procedure, then an UE context release message is transmitted to the source eNB but the source eNB does not receive the message.
This counter is cumulated when a timeout occurs since the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE during the Inter X2 HO execution procedure, then an UE context release message is transmitted to the source eNB but the source eNB does not receive the message.
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
354
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2OutFa il_X2apSigFa il
count
The cumulated number when a call is released due to receiving the X2AP signaling during the inter X2 handover execution.
This counter is cumulated number when a call is released due to receiving the X2AP signaling during the inter X2 handover execution.
Y
CC
event
int
0~214748 3647
-
-
InterX2OutC nt
count
The cumulated number when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
This counter is cumulated when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
-
CC
event
int
0~214748 3647
-
-
InterX2OutCi d
tcID
The tcID of which collection is requested
None
-
OW
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
355
Chapter 2 Counter Description
Collection Time (Success) Figure 244. Collection Time for X2 Handover Out UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterX2OutAtt
Handover Request Acknowledge
② InterX2OutPrepSucc RRC Connection Reconfiguration
SN Status Transfer
HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge ③ InterX2OutSucc
UE Context Release
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
356
Chapter 2 Counter Description
For Inter-X2 Handover Out statistics, Attempt is counted when the X2 Handover Request message can be transmitted to the target eNB after the Inter-X2 handover decision following the Measurement Report message arrival. Prepare is counted when the X2 Handover Request Acknowledge message is received from the target eNB. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE. The target eNB transmits the X2 UE Context Release message to the source eNB when the handover is successfully completed. At this point, the source eNB is counted as Success. When the procedure from 1 to 2 fails, it is counted as Prepare Fail, returning the cause value. When the procedure from 2 to 3 fails, it is counted as Inter-X2 Fail, returning the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
357
Chapter 2 Counter Description
Collection Time (Failure) Figure 245. Collection Time for InterX2OutPrepFail_CpCcFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt
Handover Request
Case 1.
ECMB reset
② Failure - InterX2OutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterX2OutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterX2OutPrepFail_CpCcFail
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
358
Chapter 2 Counter Description Figure 246. Collection Time for InterX2OutPrepFail_S1apLinkFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt
Handover Request S1AP Link is Out of Service Status
Case 1.
Case 2.
② Failure - InterX2OutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterX2OutPrepFail_S1apLinkFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
359
Chapter 2 Counter Description Figure 247. Collection Time for InterX2OutPrepFail_S1apSigFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt
Handover Request S1AP UE CONTEXT RELEASE COMMAND
Case 1.
③ Failure - InterX2OutPrepFail_S1apSigFail
Case 2.
③ Failure - InterX2OutPrepFail_S1apSigFail
S1AP RESET
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
360
Chapter 2 Counter Description Figure 248. Collection Time for InterX2OutPrepFail_X2apCuFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt
Handover Request Handover Preparation Failure
② Failure - IntraFreqOutPrepFail_X2apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
361
Chapter 2 Counter Description Figure 249. Collection Time for InterX2OutPrepFail_X2apRpTo UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt Time out
Handover Request Handover Request Acknowledge
X
② Fail - InterX2OutPrepFail_X2apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
362
Chapter 2 Counter Description Figure 250. Collection Time for InterX2OutFail_CpCcTo UE
Source eNB
Target eNB
RLC/PDCP/GTP
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① InterX2OutAtt ② InterX2OutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer Forward Path Setup Case 1.
Success Message X
③ Failure - InterX2OutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - InterX2OutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
363
Chapter 2 Counter Description Figure 251. Collection Time for InterX2OutFail_CpCcFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt ② InterX2OutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Case 1.
ECMB reset
② Failure - InterX2OutFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterX2OutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterX2OutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
364
Chapter 2 Counter Description Figure 252. Collection Time for InterX2OutFail_UpGtpFail Source eNB
UE
GTP
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① InterX2OutAtt ② InterX2OutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration
Forward Path Setup Fail Message
③ Failure - InterX2OutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
365
Chapter 2 Counter Description Figure 253. Collection Time for InterX2OutFail_UpPdcpFail Source eNB
UE
PDCP
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① InterX2OutAtt ② InterX2OutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration
Handover Exec Fail Message
③ Failure - InterX2OutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
f
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
366
Chapter 2 Counter Description Figure 254. Collection Time for InterX2OutFail_UpRlcFail Source eNB
UE
RLC
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① InterX2OutAtt ② InterX2OutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration
Re-establish Fail Message
③ Failure - InterX2OutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
367
Chapter 2 Counter Description Figure 255. Collection Time for InterX2OutFail_S1apCuFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt ② InterX2OutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - InterX2OutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
368
Chapter 2 Counter Description Figure 256. Collection Time for InterX2OutFail_S1apLinkFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt ② InterX2OutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer S1AP Link is Out of Service Status
Case 1.
③ Failure - InterX2OutFail_S1apLinkFail
SCTB reset
Case 2.
③ Failure - InterX2OutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
369
Chapter 2 Counter Description
Figure 257. Collection Time for InterX2OutFail_S1apSigFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt ② InterX2OutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND
Case 1.
③ Failure - InterX2OutFail_S1apSigFail
S1AP RESET Case 2.
③ Failure - InterX2OutFail_S1apSigFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
370
Chapter 2 Counter Description Figure 258. Collection Time for InterX2OutFail_X2apRoTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterX2OutAtt ② InterX2OutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Timerout X2relocOverall
HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release X ③ Failure - InterX2OutFail_X2apRoTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
371
Chapter 2 Counter Description
X2 In Handover This section provides statistics on the X2 handover between eNBs in reference with the target eNB. Index Name
Description
cNum
Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InAtt
count
The cumulated number of HandoverRequest messages received from the source eNB based on the target eNB.
This counter is cumulated when HandoverRequest messages received from the source eNB based on the target eNB.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepS ucc
count
The cumulated number of HandoverRequestAckno wledge messages transmitted to the source eNB after a HandoverRequest message is received from the source eNB based on the target eNB.
This counter is cumulated when HandoverRequestAcknowl edge messages transmitted to the source eNB after a HandoverRequest message is received from the source eNB based on the target eNB.
Y
CC
event
int
0~214748 3647
-
-
InterX2InSucc
count
The cumulated number of UEContextRelease messages received from
This counter is cumulated when UEContextRelease messages received from
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
372
Chapter 2 Counter Description Name
Unit
Description
Trigger
the source eNB after X2 HO is completed normally based on the target eNB.
the source eNB after X2 HO is completed normally based on the target eNB.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InPrepF ail_CpCcTo
count
The cumulated number when preparation fails due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
This counter is cumulated when preparation fails due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_CpCcFail
count
The cumulated number when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter X2 handover preparation.
This counter is cumulated when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter X2 handover preparation.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_UpGtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF
count
The cumulated number
This counter is cumulated
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
373
Chapter 2 Counter Description Name
Unit
ail_UpMacFail
Description
Trigger
when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the inter X2 HO preparation procedure.
when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the inter X2 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterX2InPrepF ail_UpPdcpFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_UpRlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails since Fail is received as a response message from the RLC block during the inter X2 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF
count
The cumulated number
This counter is cumulated
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
374
Chapter 2 Counter Description Name
Unit
ail_CpBhCacF ail
Description
Trigger
when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter X2 HO preparation procedure.
when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter X2 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterX2InPrepF ail_CpCapaCa cFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_CpQosCac Fail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_S1apLinkFa il
count
The cumulated number when preparation fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO preparation
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
375
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO preparation procedure. InterX2InPrepF ail_S1apSigFai l
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_X2apCuFail
count
The cumulated number when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF ail_X2apLinkFa il
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2InPrepF
count
The cumulated number
This counter is cumulated
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
376
Chapter 2 Counter Description Name
Unit
ail_X2apSigFai l
Description
Trigger
when preparation fails due to receiving X2AP reset Request during the inter X2 HO preparation procedure.
when preparation fails due to receiving X2AP reset Request during the inter X2 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterX2InFail_ CpCcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_ CpCcFail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter X2 HO execution procedure This counter is cumulated
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
377
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter X2 HO execution procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO execution procedure InterX2InFail_ UpGtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_ UpMacFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_ UpPdcpFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_
count
This counter is not
None
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
378
Chapter 2 Counter Description Name
Unit
UpRlcFail
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
collected in the system
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterX2InFail_ RrcHcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a RRCConnectionComple te message is not received from the UE during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that occurs when RRCConnectionComplete is not received from the UE during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_ RrcSigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_S 1apCuFail
count
The cumulated number of releases due to a S1AP specification cause that occurs during the inter X2 HO execution procedure.
This counter is cumulated when a release occurs during the inter X2 HO execution procedure due to a S1AP specification cause that occurs.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_S 1apLinkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_S
count
The cumulated number of releases due to a
This counter is cumulated when a call is released due
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
379
Chapter 2 Counter Description Name
Unit
1apPathTo
Description
Trigger
timeout that has occurred since a response message is not received after a S1AP Path Switch Request message is transmitted during the inter X2 HO execution procedure.
to a timeout that has occurred since a response message is not received after a S1AP Path Switch Request message is transmitted during the inter X2 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterX2InFail_S 1apSigFail
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_X 2apCuFail
count
The cumulated number when execution fails since a X2AP specification cause occurs during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since a X2AP specification cause occurs during the inter X2 HO execution procedure.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_X
count
This counter is not
None
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
380
Chapter 2 Counter Description Name
Unit
2apLinkFail
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
collected in the system
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterX2InFail_X 2apSigFail
count
The cumulated number of releases due to receiving a X2AP reset Request message during the inter X2 handover execution.
This counter is cumulated when a call is released due to receiving a X2AP reset Request message during the inter X2 handover execution.
Y
CC
event
int
0~214748 3647
-
-
InterX2InFail_X 2apSigTo
count
The cumulated number of releases due to a timeout that has occurred since a X2AP signaling message is not received during the inter X2 handover execution.
This counter is cumulated when a call is released due to a timeout that has occurred since a X2AP signaling message is not received during the inter X2 handover execution.
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
381
Chapter 2 Counter Description
Collection Time (Success) Figure 259. Collection Time for X2 In Handover UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release
③ InterX2InSucc
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
382
Chapter 2 Counter Description
For Inter-X2 Handover In statistics, Attempt is counted when the target eNB receives the X2 Handover Request message, and Prepare is counted after the target eNB transmits the X2 Handover Request Acknowledge message. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE. Success is counted when the handover is successfully completed and the X2 UE Context Release message is transmitted to the source eNB. When the procedure from 1 to 2 ails, it is counted as Prepare Fail, returning the cause value. When the procedure from 2 to 3 fails, it is counted as Inter-X2 In Fail, returning the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
383
Chapter 2 Counter Description
Collection Time (Failure) Figure 260. Collection Time for InterX2InPrepFail_CpCcTo UE
Source eNB
Target eNB MAC/RLC/PDCP/GTP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Forward Path Setup Case 1.
Success Message X
② Failure - InterX2InPrepFail_CpCcTo
Setup/Handover Case 2.
Success Message X
② Failure - InterX2InPrepFail_CpCcTo
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
384
Chapter 2 Counter Description
Figure 261. Collection Time for InterX2InPrepFail_CpCcFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterX2InAtt
② Failure - InterX2InPrepFail_CpCcFail
Case 1.
ECMB reset
Case 2.
Cell disabled
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterX2InPrepFail_CpCcFail
② Failure - InterX2InPrepFail_CpCcFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
385
Chapter 2 Counter Description
Figure 262. Collection Time for InterX2InPrepFail_UpGtpFail UE
Source eNB
Target eNB GTP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Forward Path Setup Fail Message
② Failure - InterX2InPrepFail_UpGtpFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
386
Chapter 2 Counter Description
Figure 263. Collection Time for InterX2InPrepFail_UpMacFail UE
Source eNB
Target eNB PHY/MAC
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Setup/Handover Fail Message
② Failure - InterX2InPrepFail_UpMacFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
387
Chapter 2 Counter Description
Figure 264. Collection Time for InterX2InPrepFail_UpPdcpFail UE
Source eNB
Target eNB PDCP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Setup/Handover Fail Message
② Failure - InterX2InPrepFail_UpPdcpFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
388
Chapter 2 Counter Description
Figure 265. Collection Time for InterX2InPrepFail_UpRlcFail UE
Source eNB
Target eNB RLC
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Setup/Handover Fail Message
② Failure - InterX2InPrepFail_UpRlcFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
389
Chapter 2 Counter Description
Figure 266. Collection Time for InterX2InPrepFail_CpBhCacFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterX2InAtt
Failure by CAC (Call Admission Control) based on Backhaul Bandwidth
② Fail - InterX2InPrepFail_CpBhCacFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
390
Chapter 2 Counter Description
Figure 267. Collection Time for InterX2InPrepFail_CpCapaCacFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterX2InAtt
Failure by CAC (Call Admission Control) based on Call Count per Cell or CAC based on DRB Count per Cell
② Fail - InterX2InPrepFail_CpCapaCacFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
391
Chapter 2 Counter Description
Figure 268. Collection Time for InterX2InPrepFail_CpQosCacFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterX2InAtt
Failure by CAC (Call Admission Control) based on QoS
② Fail - InterX2InPrepFail_CpQosCacFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
392
Chapter 2 Counter Description
Figure 269. Collection Time for InterX2InPrepFail_S1apLinkFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
Case 1.
① InterX2InAtt S1AP Link is Out of Service Status
② Failure - InterX2InPrepFail_S1apLinkFail
SCTB reset Case 2.
② Failure - InterX2InPrepFail_S1apLinkFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
393
Chapter 2 Counter Description
Figure 270. Collection Time for InterX2InPrepFail_S1apSigFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterX2InAtt S1AP RESET
Case 1.
② Failure - InterX2InPrepFail_S1apSigFail S1AP UE CONTEXT RELEASE COMMAND
Case 2.
② Failure - InterX2InPrepFail_S1apSigFail
Handover Preparation Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
394
Chapter 2 Counter Description
Figure 271. Collection Time for InterX2InPrepFail_X2apCuFail UE
Source eNB
Target eNB MAC/RLC/PDCP/GTP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Forward Path Setup Success Message Setup/Handover Success Message Internal Block Failure Handover Cancel ② Failure - InterX2InPrepFail_X2apCuFail Release Request Success Message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
395
Chapter 2 Counter Description
Figure 272. Collection Time for InterX2InPrepFail_X2apSigFail UE
Source eNB
Target eNB MAC/RLC/PDCP/GTP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Forward Path Setup Success Message Setup/Handover X2AP Reset triggering from ECCB
Success Message
X2AP RESET REQUEST ② Failure - InterX2InPrepFail_X2apSigFail Release Request Success Message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
396
Chapter 2 Counter Description
Figure 273. Collection Time for InterX2InFail_CpCcTo (1) UE
Target eNB
Source eNB
EPC
GTP
ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Handover Request Acknowledge ② InterX2InPrepSucc
RRC Connection Reconfiguration SN Status Transfer RRC Connection Reconfiguration Complete
Path Switch Request
S-GW Change Request Time out
S-GW Change Conf
X
Path Switch Request Acknowledge
③ Failure - InterX2InFail_CpCcTo
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
397
Chapter 2 Counter Description
Figure 274. Collection Time for InterX2InFail_CpCcTo (2) UE
Target eNB
Source eNB
EPC
GTP
ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Handover Request Acknowledge ② InterX2InPrepSucc
RRC Connection Reconfiguration SN Status Transfer RRC Connection Reconfiguration Complete
Handover Complete
Time out
Handover Complete Success X
③ Failure - InterX2InFail_CpCcTo
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
398
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
399
Chapter 2 Counter Description Figure 275. Collection Time for InterX2InFail_CpCcFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete
Case 1.
ECMB reset
② Failure - InterX2InFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterX2InFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterX2InFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
400
Chapter 2 Counter Description Figure 276. Collection Time for InterX2InFail_UpGtpFail UE
Source eNB
Target eNB GTP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Handover Request Acknowledge ② InterX2InPrepSucc
RRC Connection Reconfiguration SN Status Transfer RRC Connection Reconfiguration Complete
Path Switch Request
S-GW Change Request S-GW Change Failure
Path Switch Request Acknowledge
③ Failure - InterX2InFail_UpGtpFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
401
Chapter 2 Counter Description
Figure 277. Collection Time for InterX2InFail_UpPdcpFail UE
Source eNB
Target eNB PDCP
EPC ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① InterX2InAtt Handover Request Acknowledge ② InterX2InPrepSucc
RRC Connection Reconfiguration SN Status Transfer RRC Connection Reconfiguration Complete
Handover Complete Handover Complete Failure
③ Failure - InterX2InFail_UpPdcpFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
402
Chapter 2 Counter Description
Figure 278. Collection Time for InterX2InFail_RrcHcTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
RRC Connection Reconfiguration
Handover Request Acknowledge
① InterX2InAtt ② InterX2InPrepSucc
Time Out SN Status Transfer RRC Connection Reconfiguration Complete
X
③ Failure - InterX2InFail_RrcHcTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
403
Chapter 2 Counter Description Figure 279. Collection Time for InterX2InFail_S1apLinkFail UE
EPC MME SGW
Target eNB
Source eNB Measurement Report HO Decision Handover Request RRC Connection Reconfiguration
Handover Request Acknowledge
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete S1AP Link is Out of Service Status ② Failure - InterX2InFail_S1apLinkFail
Case 1.
Case 2.
SCTB reset
② Failure - InterX2InFail_S1apLinkFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
404
Chapter 2 Counter Description
Figure 280. Collection Time for InterX2InFail_S1apCuFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge RRC Connection Reconfiguration
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Failure ③ Failure - InterX2InFail_S1apCuFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
405
Chapter 2 Counter Description
Figure 281. Collection Time for InterX2InFail_S1apPathTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge RRC Connection Reconfiguration
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete Path Switch Request Time Out
Path Switch Request Acknowledge
X
③ Failure - InterX2InFail_S1apPathTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
406
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
407
Chapter 2 Counter Description Figure 282. Collection Time for InterX2InFail_S1apSigFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete Path Switch Request S1AP RESET Case 1.
② Failure - InterX2InPrepFail_S1apSigFail
S1AP UE CONTEXT RELEASE COMMAND Case 2.
② Failure - InterX2InPrepFail_S1apSigFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
408
Chapter 2 Counter Description
Figure 283. Collection Time for InterX2InFail_X2apSigFail UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
RRC Connection Reconfiguration
Handover Request Acknowledge
① InterX2InAtt ② InterX2InPrepSucc
SN Status Transfer RRC Connection Reconfiguration Complete X2AP Reset triggering from ECCB
X2AP RESET REQUEST
③ Failure - InterX2InFail_X2apSigFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
409
Chapter 2 Counter Description
Figure 284. Collection Time for InterX2InFail_X2apSigTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
RRC Connection Reconfiguration
Handover Request Acknowledge
① InterX2InAtt ② InterX2InPrepSucc Timer Out
SN Status Transfer
X
RRC Connection Reconfiguration Complete
③ Failure - InterX2InFail_X2apSigFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
410
Chapter 2 Counter Description
S1 Out Handover This section provides statistics on the S1 handovers between eNBs for each cell in reference with the source eNB. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1OutAtt
count
The cumulated number when inter S1 HO is judged in the HO decision after a measurement report message is received. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
This counter is cumulated when inter S1 HO is judged in the HO decision after a measurement report message is received.
Y
CC
event
int
0~2147483647
-
-
InterS1OutPrepS
count
The cumulated number when the transmission
This counter is cumulated when a
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
411
Chapter 2 Counter Description Name
Unit
ucc
InterS1OutSucc
count
Description
Trigger
of the RRC connection reconfiguration message to the UE is completed by receiving a S1 handover command message from MME after transmitting a S1 handover required message to MME when inter S1 HO is judged in the HO decision after a measurement report is received.
S1 handover required message is transmitted to MME and a S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after the measurement report message is received.
The cumulated number when the source eNB normally receives an UE context release command message transmitted by the target eNB after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE.
This counter is cumulated when the source eNB normally receives the UE context release command message after inter S1 HO is executed, the source eNB transmits the RRC connection reconfiguration message to the UE, the target eNB receives the RRC connection reconfiguration complete message from the UE, and the target eNB transmits the UE context release command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
412
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
message to the source eNB. InterS1OutPrepF ail_CpCcFail
count
The cumulated number when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during inter S1 handover preparation.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter S1 HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in
413
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
the execution of an audit of UE information during the inter S1 HO preparation procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter S1 HO preparation procedure InterS1OutPrepF ail_S1apCuFail
count
The cumulated number when preparation fails since a S1AP specification cause occurs during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails since a S1AP specification cause occurs during the inter S1 HO preparation procedure.
Y
CC
event
int
0~2147483647
-
-
InterS1OutPrepF ail_S1apLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~2147483647
-
-
InterS1OutPrepF ail_S1apRpTo
count
The cumulated number when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1
This counter is cumulated when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
414
Chapter 2 Counter Description Name
Unit
Description
Trigger
handover required message to MME during the inter S1 HO preparation.
after transmitting a S1 handover required message to MME during the inter S1 HO preparation.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1OutPrepF ail_S1apSigFail
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter S1 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter S1 HO preparation procedure.
Y
CC
event
int
0~2147483647
-
-
InterS1OutFail_ CpCcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
415
Chapter 2 Counter Description Name
InterS1OutFail_ CpCcFail
Unit
count
Description
Trigger
message is transmitted to the inner block during the inter S1 HO execution procedure.
received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter S1 HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
416
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO execution procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Inter S1 HO execution procedure InterS1OutFail_ UpGtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
Y
CC
event
int
0~2147483647
-
-
InterS1OutFail_ UpMacFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~2147483647
-
-
InterS1OutFail_ UpPdcpFail
count
The cumulated number when execution fails since Fail is received as a response message
This counter is cumulated when execution fails since Fail is received as a
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
417
Chapter 2 Counter Description Name
Unit
Description
Trigger
from the PDCP block during the inter S1 HO execution procedure.
response message from the PDCP block during the inter S1 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1OutFail_ UpRlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the MAC block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter S1 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter S1 HO execution procedure.
Y
CC
event
int
0~2147483647
-
-
InterS1OutFail_ RrcSigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~2147483647
-
-
InterS1OutFail_S 1apCuFail
count
The cumulated number when execution fails
This counter is cumulated when
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
418
Chapter 2 Counter Description Name
Unit
Description
Trigger
since a S1AP specification cause occurs during the inter S1 HO execution procedure.
execution fails since a S1AP specification cause occurs during the inter S1 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1OutFail_S 1apLinkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter S1 HO execution procedure.
Y
CC
event
int
0~2147483647
-
-
InterS1OutFail_S 1apRoTO
count
The cumulated number when timeout occurs during the inter S1 HO execution procedure since the source eNB transmits a RRC connection reconfiguration message to the UE,
This counter is cumulated when timeout occurs during the inter S1 HO execution procedure since the source eNB transmits a RRC connection
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
419
Chapter 2 Counter Description Name
InterS1OutFail_S 1apSigFail
Unit
count
Description
Trigger
then the target eNB receives a RRC reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
reconfiguration message to the UE, then the target eNB receives a RRC reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
420
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1 HO execution procedure. InterS1OutCnt
count
The cumulated number when inter S1 HO is judged in the HO decision after a measurement report message is received.
This counter is cumulated when inter S1 HO is judged in the HO decision after a measurement report message is received.
-
CC
event
int
0~2147483647
-
-
InterS1OutCid
tcID
The tcID of which collection is requested
This counter is updated when the S1 Out Handover is collected
-
OW
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
421
Chapter 2 Counter Description
Collection Time Figure 285. Collection Time for S1 Handover Out UE
Source eNB
Target eNB
MME
S/GW
UE moves to Inter eNB Cell Measurement Report HO Decision
1
Attempt Handover Required Handover Request
2
Handover Request Acknowledge
Prepare
Handover Command
Rrc Connection Reconfiguration
eNB Status Transfer MME Status Transfer Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
3
Success
422
Chapter 2 Counter Description
For Inter-S1 Handover Out statistics, Attempt is counted when the S1 Handover Required message can be transmitted to the MME after the inter S1 handover decision following the Measurement Report message arrival. Prepare is counted when the S1 Handover Command message is received from the MME. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE. The MME transmits the S1 UE Context Release Command message to the source eNB when the handover is successfully completed in the target eNB. At this point, the source eNB is counted as Success. When the procedure from 1 to 2 fails, it is counted as Prepare Fail and returns the cause value, and when the procedure from 2 to 3 fails, it is counted as Inter-S1 Out Fail and returns the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
423
Chapter 2 Counter Description Figure 286. Collection Time for InterS1OutPrepFail_CpCcFail(1) Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required
Handover Request Prepare
2
ECMB reset
Handover Request Acknowledge
Failure - IntraS1OutPrepFail_CpCcFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
424
Chapter 2 Counter Description Figure 287. Collection Time for InterS1OutPrepFail_CpCcFail(2) Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required
Handover Request Prepare
2
Cell disabled
Handover Request Acknowledge
Failure - IntraS1OutPrepFail_CpCcFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
425
Chapter 2 Counter Description Figure 288. Collection Time for InterS1OutPrepFail_CpCcFail(3) Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required
Prepare
2
Mismatch of UE information in the execution of audit between the ECCB and RLC/ MAC
Handover Request Handover Request Acknowledge
Failure - IntraS1OutPrepFail_CpCcFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
426
Chapter 2 Counter Description Figure 289. Collection Time for InterS1OutPrepFail_S1apCuFail Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required Handover Request Prepare
Handover Request Acknowledge
2
S1AP UE CONTEXT RELEASE COMMAND Failure - IntraS1OutPrepFail_S1apCpCuFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
427
Chapter 2 Counter Description Figure 290. Collection Time for InterS1OutPrepFail_S1apLinkFail Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required Handover Request Prepare
Handover Request Acknowledge
2
S1AP Link is Out Of Service Status
X Failure - InterS1OutPrepFail_S1apLinkFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
428
Chapter 2 Counter Description Figure 291. Collection Time for InterS1OutPrepFail_S1apLinkFail Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required Handover Request Prepare
Handover Request Acknowledge
2 SCTB reset Failure - InterS1OutPrepFail_S1apLinkFail
Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
429
Chapter 2 Counter Description Figure 292. Collection Time for InterS1OutPrepFail_S1apRpTo Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required Handover Request Timer relocprep Prepare
Handover Request Acknowledge
2 Failure - InterS1OutPrepFail_S1apRpTo
Handover Cancel Handover Command
RRC Connected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
430
Chapter 2 Counter Description Figure 293. Collection Time for InterS1OutPrepFail_S1apSigFail (1) Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required Handover Request Prepare
Handover Request Acknowledge
2
S1AP UE CONTEXT RELEASE COMMAND Failure - IntraS1OutPrepFail_S1apSigFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
431
Chapter 2 Counter Description Figure 294. Collection Time for InterS1OutPrepFail_S1apSigFail (2) Source eNB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell
Measurement Report
Attempt
1
HO Decision
Target Cell Preparation Handover Required Handover Request Prepare
Handover Request Acknowledge
2
RESET Failure - IntraS1OutPrepFail_S1apSigFail Handover Command
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
432
Chapter 2 Counter Description Figure 295. Collection Time for InterS1OutFail_CpCcTo (1) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision
Target Cell Preparation Rrc Connection Reconfiguration Forward PathSetup Timer Internal ForwardPathSetup Success Message
Execution
3
X
Failure - InterS1OutFail_CpCcTo eNB Status Transfer MME Status Transfer
Rrc Connection Reconfiguration Complete
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
433
Chapter 2 Counter Description Figure 296. Collection Time for InterS1OutFail_CpCcTo (2) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision
Target Cell Preparation Rrc Connection Reconfiguration ReestablishControl Timer Internal ReestablishControl Success Message
Execution
3
X
Failure - InterS1OutFail_CpCcTo
eNB Status Transfer MME Status Transfer Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) Completion
4
UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
434
Chapter 2 Counter Description Figure 297. Collection Time for InterS1OutFail_CpCcTo (3) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration
Execution
eNB Status Transfer
3 Rrc Connection Reconfiguration Complete
MME Status Transfer
Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command Buffer Flush Completion
Timer Internal BufferFlush
4 Success Message
X
Failure - InterS1OutFail_CpCcTo UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
435
Chapter 2 Counter Description Figure 298. Collection Time for InterS1OutFail_CpCcFail (1) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration
eNB Status Transfer MME Status Transfer ECMB reset
Execution
3
Failure - IntraS1OutPrepFail_CpCcFail
Handover Notify
Rrc Connection Reconfiguration Complete
Tracking Area Update Procedure (NAS) Completion
4
UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
436
Chapter 2 Counter Description
Figure 299. Collection Time for InterS1OutFail_CpCcFail (2) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration
eNB Status Transfer MME Status Transfer Cell disabled
Execution
3 Failure - IntraS1OutPrepFail_CpCcFail
Handover Notify
Rrc Connection Reconfiguration Complete
Tracking Area Update Procedure (NAS) Completion
4
UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
437
Chapter 2 Counter Description Figure 300. Collection Time for InterS1OutFail_CpCcFail (3) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration
Execution
3
eNB Status Transfer
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC Failure - IntraS1OutPrepFail_CpCcFail
MME Status Transfer
Handover Notify
Rrc Connection Reconfiguration Complete
Tracking Area Update Procedure (NAS) Completion
4
UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
438
Chapter 2 Counter Description Figure 301. Collection Time for InterS1OutFail_UpGtpFail Source eNB
Source eNB
GTP
ECCB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration Forward PathSetup Fail Message
Execution
3
Failure - InterS1OutFail_UpGtpFail eNB Status Transfer
Rrc Connection Reconfiguration Complete
MME Status Transfer
Handover Notify Tracking Area Update Procedure (NAS) Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
439
Chapter 2 Counter Description Figure 302. Collection Time for InterS1OutFail_UpPdcpFail Source eNB
Source eNB
PDCP
ECCB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration Handover Exec Fail Message
Execution
3
Failure - InterS1OutFail_UpPdcpFail eNB Status Transfer
Rrc Connection Reconfiguration Complete
MME Status Transfer
Handover Notify Tracking Area Update Procedure (NAS) Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
440
Chapter 2 Counter Description Figure 303. Collection Time for InterS1OutFail_UpRlcFail Source eNB
Source eNB
RLC
ECCB
UE
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report
Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration Re-establish Fail Message
Execution
3
Failure - InterS1OutFail_UpRlcFail eNB Status Transfer
Rrc Connection Reconfiguration Complete
MME Status Transfer
Handover Notify Tracking Area Update Procedure (NAS) Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
441
Chapter 2 Counter Description
Figure 304. Collection Time for InterS1OutFail_S1apCuFail Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration eNB Status Transfer MME Status Transfer
Execution
3
S1AP UE CONTEXT RELEASE COMMAND Failure - IntraS1OutPrepFail_S1apCuFail Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS)
Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
442
Chapter 2 Counter Description
Figure 305. Collection Time for InterS1OutFail_S1apLinkFail (1) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration eNB Status Transfer MME Status Transfer
Execution
3
S1AP Link is Out Of Service Status
X
Failure - InterS1OutFail_S1apLinkFail Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
443
Chapter 2 Counter Description
Figure 306. Collection Time for InterS1OutFail_S1apLinkFail (2) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration eNB Status Transfer MME Status Transfer
Execution
3
SCTB reset Failure - InterS1OutFail_S1apLinkFail Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS)
Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
444
Chapter 2 Counter Description
Figure 307. Collection Time for InterS1OutFail_S1apRoTo Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration eNB Status Transfer MME Status Transfer
Execution
Timer RelocOverall
3
Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) Completion
4 Failure - InterS1OutFail_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
UE Context Release Command UE Context Release Complete
445
Chapter 2 Counter Description
Figure 308. Collection Time for InterS1OutFail_S1apSigFail (1) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration eNB Status Transfer MME Status Transfer
Execution
3
S1AP UE CONTEXT RELEASE COMMAND Failure - IntraS1OutPrepFail_S1apCuFail Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS)
Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
446
Chapter 2 Counter Description
Figure 309. Collection Time for InterS1OutFail_S1apSigFail (2) Source eNB RLC/PDCP/ GTP
UE
Source eNB ECCB
Target eNB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report Attempt
1
Prepare
2
HO Decision Target Cell Preparation Rrc Connection Reconfiguration eNB Status Transfer MME Status Transfer
Execution
3
RESET Failure - IntraS1OutPrepFail_S1apCuFail Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS)
Completion
4 UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
447
Chapter 2 Counter Description
S1 In Handover This section provides statistics on the S1 handovers between eNBs for each cell in reference with the target eNB. Index Name
Description
cNum
Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InAtt
count
The cumulated number of S1 handover request messages received by the target eNB.
This counter is cumulated when S1 handover request messages is received by the target eNB.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrepSucc
count
The cumulated number of S1 handover request acknowledge messages transmitted by the target eNB after it receives a S1 handover request message.
This counter is cumulated when S1 handover request acknowledge messages is transmitted by the target eNB after it receives a S1 handover request message.
Y
CC
event
int
0~21474 83647
-
-
InterS1InSucc
count
The cumulated number of S1 handover notify messages transmitted
This counter is cumulated when S1 handover notify
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
448
Chapter 2 Counter Description Name
Unit
Description
Trigger
when the handover is completed normally after the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB normally receives a RRC connection reconfiguration complete message.
messages is transmitted when the handover is completed normally after the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB normally receives a RRC connection reconfiguration complete message.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InPrep_Fail CpCcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO preparation procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail CpCcFail
count
The cumulated numer when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during inter S1 handover preparation.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO preparation
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
449
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter S1 HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO preparation procedure. This counter is cumulated when a call is released Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
450
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
due to failure of ECCB resource allocation during Inter S1 HO preparation procedure InterS1InPrep_Fail UpGtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail UpMacFail
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the MAC block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail UpPdcpFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
451
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InPrep_Fail UpRlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail CpBhCacFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail CpCapaCacFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
452
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InPrep_Fail CpQosCacFail
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail S1apCuFail
count
The cumulated number when preparation fails since a S1AP specification cause occurs during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails since a S1AP specification cause occurs during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail S1apLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1InPrep_Fail S1apSigFail
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter S1 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO preparation
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
453
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter S1 HO preparation procedure. InterS1InFail_CpC cTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InFail_CpC cFail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO execution procedure. This counter is
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
454
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter S1 HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO execution procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
455
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Inter S1 HO execution procedure InterS1InFail_UpG tpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InFail_UpM acFail
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the MAC block during the inter S1 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
456
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
execution procedure. InterS1InFail_UpP dcpFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InFail_UpRl cFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the MAC block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter S1 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter S1 HO
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
457
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
execution procedure. InterS1InFail_RrcH cTo
count
The cumulated number when a call is released due to a timeout that has occurred since RRCConnectionComplete is not received from the UE or a response message is not received from the inner blocks (PDCP, RLC, MAC) during the inter S1 HO execution procedure.
This counter is cumulated when timeout occurs since RRCConnectionC omplete is not received from the UE during the inter S1 HO execution procedure. This counter is cumulated when a call is released due to a timeout that occurs since a response message is not received from the inner blocks (PDCP, RLC, MAC) during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InFail_RrcS igFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1InFail_S1a pCuFail
count
The cumulated number when execution fails since a S1AP specification cause occurs during the
This counter is cumulated when execution fails since a S1AP specification
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
458
Chapter 2 Counter Description Name
Unit
Description
Trigger
inter S1 HO execution procedure.
cause occurs during the inter S1 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InFail_S1a pLinkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InFail_S1a pSigFail
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
459
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474 83647
-
-
MME during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter S1 HO execution procedure. InterS1InFail_S1a pSigTo
count
The cumulated number of timeouts that occur when the TeNB does not receive a S1AP MME status transfer message from MME after the SeNB transmits a S1AP eNB status transfer message to MME during the inter S1 HO execution.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the TeNB does not receive a S1AP MME status transfer message from MME after the SeNB transmits a S1AP eNB status transfer message to MME during the inter S1 HO execution, and timeout occurred.
460
Chapter 2 Counter Description
Collection Time (Success) Figure 310. Collection Time for S1 Handover In UE
Source eNB
Target eNB
MME
S/GW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
Rrc Connection Reconfiguration
Attempt
1
Prepare
2
Handover Request Handover Request Acknowledge
Handover Command eNB Status Transfer
Rrc Connection Reconfiguration Complete
MME Status Transfer Handover Notify
Success
3
Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
461
Chapter 2 Counter Description
For inter S1 handover in statistics, when the target eNB receives the S1 Handover Request message, it is counted as Attempt; when the target eNB transmits the S1 Handover Request Acknowledge message, it is counted as Prepare. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE. Success is counted after the handover is successfully completed and the S1 Handover Notify message is transmitted to the MME. When the procedure from 1 to 2 fails, it is counted as Prepare Fail, returning the cause value. When the procedure from 2 to 3 fails, it is counted as Inter S1 In Fail, returning the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
462
Chapter 2 Counter Description
Collection Time (Failure) Figure 311. Collection Time for InterS1InPrep_FailCpCcTo Target eNB ECCB
Source eNB
UE
Target eNB RLC/PDCP/ GTP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup Timer Internal Resource Setup
Prepare
2 Failure - InterS1InPrep_FailCpCcTo
X
Success Message Handover Failure
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
463
Chapter 2 Counter Description
Figure 312. Collection Time for InterS1InPrep_FailCpCcFail (1) Target eNB Source eNB
UE
ECCB
Target eNB RLC/PDCP/ GTP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
ECMB reset Failure - IntraS1InPrep_FailCpCcFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
464
Chapter 2 Counter Description
Figure 313. Collection Time for InterS1InPrep_FailCpCcFail (2) Target eNB Source eNB
UE
ECCB
Target eNB RLC/PDCP/ GTP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Cell disabled Failure - IntraS1InPrep_FailCpCcFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
465
Chapter 2 Counter Description
Figure 314. Collection Time for InterS1InPrep_FailCpCcFail (3) Target eNB Source eNB
UE
ECCB
Target eNB RLC/PDCP/ GTP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC Failure - IntraS1InPrep_FailCpCcFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
466
Chapter 2 Counter Description
Figure 315. Collection Time for InterS1InPrep_FailCpCcFail (4) Target eNB Source eNB
UE
ECCB
Target eNB RLC/PDCP/ GTP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Target cell resource allocation Failure
Prepare
2
Resource Setup Failure X - IntraS1IntPrep_FailCpCcFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
467
Chapter 2 Counter Description
Figure 316. Collection Time for InterS1InPrep_FailUpGtpFail
Source eNB
UE
Target eNB
Target eNB
ECCB
GTP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup Fail Message
Prepare
2
Failure - IntraS1InPrep_FailUpGtpFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
468
Chapter 2 Counter Description
Figure 317. Collection Time for InterS1InPrep_FailUpMacFail
Source eNB
UE
Target eNB
Target eNB
ECCB
MAC
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup Fail Message
Prepare
2
Failure - IntraS1InPrep_FailUpMacFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
469
Chapter 2 Counter Description
Figure 318. Collection Time for InterS1InPrep_FailUpPdcpFail
Source eNB
UE
Target eNB
Target eNB
ECCB
PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup Fail Message
Prepare
2
Failure - IntraS1InPrep_FailUpPdcpFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
470
Chapter 2 Counter Description
Figure 319. Collection Time for InterS1InPrep_FailUpRlcFail
Source eNB
UE
Target eNB
Target eNB
ECCB
RLC
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup Fail Message
Prepare
2
Failure - IntraS1InPrep_FailUpRlcFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
471
Chapter 2 Counter Description
Figure 320. Collection Time for InterS1InPrep_FailCpBhCacFail Target eNB Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
ECCB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request CAC based on Backhaul Bandwidth Fail
Prepare
2
Failure - InterS1InPrep_FailCpBhCacFail Resource Setup
X
Handover Failure
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
472
Chapter 2 Counter Description
Figure 321. Collection Time for InterS1InPrep_FailCpCapaCacFail Target eNB Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
ECCB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
Prepare
1
2
Handover Request CAC based on Call Count per Cell Fail or CAC based on DRB Count per Cell Fail Failure - InterS1InPrep_CpCapaCacFail Resource Setup
X
Handover Failure
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
473
Chapter 2 Counter Description
Figure 322. Collection Time for InterS1InPrep_FailCpQosCacFail Target eNB Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
ECCB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request
CAC based on QoS Fail Prepare
2
Failure - InterS1InPrep_CpQosCacFail Resource Setup
X
Handover Failure
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
474
Chapter 2 Counter Description
Figure 323. Collection Time for InterS1InPrep_FailS1apCuFail Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup S1AP UE CONTEXT RELEASE COMMAND
Prepare
2
Failure - IntraEnbPrepFail_S1apCuFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
475
Chapter 2 Counter Description
Figure 324. Collection Time for InterS1InPrep_FailS1apLinkFail(1) Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup S1AP Link is Out Of Service Status
Prepare
X
2
Failure - IntraEnbPrepFail_S1apLinkFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
476
Chapter 2 Counter Description
Figure 325. Collection Time for InterS1InPrep_FailS1apLinkFail (2) Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup SCTB reset
Prepare
2 Failure - InterS1InPrep_FailS1apLinkFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
477
Chapter 2 Counter Description
Figure 326. Collection Time for InterS1InPrepFail_S1apSigFail (1) Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup S1AP UE CONTEXT RELEASE COMMAND
Prepare
2
Failure - IntraEnbPrepFail_S1apSigFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
478
Chapter 2 Counter Description
Figure 327. Collection Time for InterS1InPrepFail_S1apSigFail (2) Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision
Handover Required Attempt
1
Handover Request Resource Setup RESET
Prepare
2
Failure - IntraEnbPrepFail_S1apSigFail Handover Failure Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
479
Chapter 2 Counter Description
Figure 328. Collection Time for InterS1InFail_CpCcTo Target eNB Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
ECCB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Handover Request Acknowledge
Timer InterEnb HoComplete Rrc Connection Reconfiguration Execution
Handover Command eNB Status Transfer MME Status Transfer
3
Rrc Connection Reconfiguration Complete Failure - InterS1InFail_CpCcTo
X
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
480
Chapter 2 Counter Description
Figure 329. Collection Time for InterS1InFail_CpCcFail (1) Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer ECMB reset
Failure - InterS1InFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
481
Chapter 2 Counter Description
Figure 330. Collection Time for InterS1InFail_CpCcFail (2) Target eNB Source eNB
UE
ECCB
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer Cell disabled
Failure - InterS1InFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
482
Chapter 2 Counter Description
Figure 331. Collection Time for InterS1InFail_CpCcFail (3) Target eNB Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
ECCB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC
Failure - InterS1InFail_CpCcFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
483
Chapter 2 Counter Description
Figure 332. Collection Time for InterS1InFail_UpPdcpFail Target eNB Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
ECCB
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Handover Request Acknowledge
Timer InterEnb HoComplete Rrc Connection Reconfiguration Execution
Handover Command eNB Status Transfer MME Status Transfer
3
Rrc Connection Reconfiguration Complete
X Failure - InterS1InFail_RrcHcTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
484
Chapter 2 Counter Description
Figure 333. Collection Time for InterS1InFail_RrcHcTo Target eNB ECCB
Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Handover Request Acknowledge
Timer InterEnb HoComplete Rrc Connection Reconfiguration Execution
Handover Command eNB Status Transfer MME Status Transfer
3
Rrc Connection Reconfiguration Complete
X
Failure - InterS1InFail_RrcHcTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
485
Chapter 2 Counter Description
Figure 334. Collection Time for InterS1InFail_S1apCuFail
Source eNB
UE
Target eNB
Target eNB
ECCB
PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer S1AP UE CONTEXT RELEASE COMMAND Failure Rrc Connection Reconfiguration Complete - IntraEnbPrepFail_S1apCuFail
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
486
Chapter 2 Counter Description
Figure 335. Collection Time for InterS1InFail_S1apLinkFail (1)
Source eNB
UE
Target eNB
Target eNB
ECCB
PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer S1AP Link is Out Of Service Status
X Failure - IntraEnbPrepFail_S1apLinkFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
487
Chapter 2 Counter Description
Figure 336. Collection Time for InterS1InFail_S1apLinkFail (2)
Source eNB
UE
Target eNB
Target eNB
ECCB
PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Handover Request Acknowledge
Rrc Connection Reconfiguration
Handover Command eNB Status Transfer MME Status Transfer
Execution
3
SCTB reset Failure - IntraEnbPrepFail_S1apLinkFail Rrc Connection Reconfiguration Complete
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
488
Chapter 2 Counter Description
Figure 337. Collection Time for InterS1InFail_S1apSigFail (1)
Source eNB
UE
Target eNB
Target eNB
ECCB
PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer S1AP UE CONTEXT RELEASE COMMAND Failure - IntraEnbPrepFail_S1apSigFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
489
Chapter 2 Counter Description
Figure 338. Collection Time for InterS1InFail_S1apSigFail (2)
Source eNB
UE
Target eNB
Target eNB
ECCB
PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Rrc Connection Reconfiguration Execution
3
Handover Request Acknowledge Handover Command eNB Status Transfer MME Status Transfer RESET Failure - IntraEnbPrepFail_S1apSigFail Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
490
Chapter 2 Counter Description
Figure 339. Collection Time for InterS1InFail_S1apSigTo Target eNB ECCB
Source eNB
UE
Target eNB MAC/RLC/ GTP/PDCP
MME
S/GW
UE moves to Iner eNB Cell Measurement Report HO Decision Handover Required Attempt
1
Handover Request Resource Setup
Prepare
2
Handover Request Acknowledge Timer InterEnb HoComplete
Rrc Connection Reconfiguration Execution
3
Handover Command Failure - InterS1InFail_RrcHcTo
eNB Status Transfer MME Status Transfer
X
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
491
Chapter 2 Counter Description
Handover Time This section provides statistics on the average setup time and the maximum setup time of the handover interrupt time in the TeNB for each cell. Index Name
Description
cNum
Cell Id
scID
Source Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraHoTimeA vg
ms
The average time taken from transmitting the RRCConnection Reconfiguration message to the UE until after receiving the RRCConnectionReconfi gurationComplete message from the UE.
This counter is calculated when measurement period comes.
Y
GAUGE
event
float
0~3.4*10 ^38
IntraHoTimeTot/ IntraHoTimeCnt
sum(IntraHoTimeTot)/ sum(IntraHoTimeCnt)
IntraHoTimeM ax
ms
The maximum value of IntraHoTimeAvg
This counter is updated when IntraHoTimeAvg is collected and it is greater than previous maximum value.
Y
GAUGE
event
float
0~3.4*10 ^38
-
max(IntraHoTimeMax)
IntraHoTimeT
ms
The cumulated time
This counter is
Y
GAUGE
event
float
0~3.4*10
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
492
Chapter 2 Counter Description Name
Unit
ot
Description
Trigger
taken from transmitting the RRCConnection Reconfiguration message to the UE until after receiving the RRCConnectionReconfi gurationComplete message from the UE.
cumulated when IntraHoTimeAvg is collected
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
^38
IntraHoTimeC nt
count
The cumulated collection count of IntraHoTimeAvg
This counter is cumulated when IntraHoTimeAvg is collected
Y
GAUGE
event
int
0~214748 3647
-
-
S1HoTimeAvg
ms
The average time taken from transmitting the S1apHandoverRequest Acknowledg message to MME by TeNB until after receiving the RRCConnectionReconfi gurationComplete message from the UE.
This counter is calculated when measurement period comes.
Y
GAUGE
event
float
0~3.4*10 ^38
S1HoTimeTot/S 1HoTimeCnt
sum(S1HoTimeTot)/s um(S1HoTimeCnt)
S1HoTimeMax
ms
The maximum number of S1HoTimeAvg
This counter is updated when S1HoTimeAvg is collected and it is greater than previous maximum value.
Y
GAUGE
event
float
0~3.4*10 ^38
-
max(S1HoTimeMax)
S1HoTimeTot
ms
The average time taken from transmitting the S1apHandoverRequest Acknowledge message to MME by TeNB until
This counter is cumulated when S1HoTimeAvgr is collected
Y
GAUGE
event
float
0~3.4*10 ^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
493
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
after receiving the RRCConnectionReconfi gurationComplete message from the UE. S1HoTimeCnt
count
The cumulated collection count of S1HoTimeAvg
This counter is cumulated when S1HoTimeAvgr is collected
Y
GAUGE
event
int
0~214748 3647
-
-
X2HoTimeAvg
ms
The average time taken from transmitting the X2apHandoverRequest Acknowledge message to MME by TeNB until after receiving the RRCConnectionReconfi gurationComplete message from the UE.
This counter is calculated when measurement period comes.
Y
GAUGE
event
float
0~3.4*10 ^38
X2HoTimeTot/X 2HoTimeCnt
sum(X2HoTimeTot)/s um(X2HoTimeCnt)
X2HoTimeMax
ms
The maximum number of X2HoTimeAvg
This counter is updated when X2HoTimeAvg is collected and it is greater than previous maximum value.
Y
GAUGE
event
float
0~3.4*10 ^38
-
max(X2HoTimeMax)
X2HoTimeTot
ms
The average time taken from transmitting the X2apHandoverRequest Acknowledge message to MME by TeNB until after receiving the RRCConnectionReconfi gurationComplete message from the UE.
This counter is cumulated when X2HoTimeAvg is collected
Y
GAUGE
event
float
0~3.4*10 ^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
494
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
X2HoTimeCnt
count
The cumulated collection count of X2HoTimeAvg
This counter is cumulated when X2HoTimeAvg is collected
Y
GAUGE
event
int
0~214748 3647
-
-
HoTimeCnt
count
The cumulated collection count of HoTime
This counter is cumulated when HoTime is collected
-
CC
event
int
0~214748 3647
-
-
HoTimeCid
scID
The scID which collection is requested
This counter is updated when HoTime is collected
-
OW
event
int
0~214748 3647
-
-
Collection Time Figure 340. Collection Time for Handover Time (Intra) UE
eNB UE moves to Intra eNB Cell Measurement Report HO Decision
Rrc Connection Reconfiguration HO Time
Target Cell Preparation
Rrc Connection Reconfiguration Complete Internal Path Switch
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
495
Chapter 2 Counter Description Figure 341. Collection Time for Handover Time(Inter S1) UE
Source eNB
Target eNB
MME
S/GW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required Handover Request Handover Request Acknowledge Rrc Connection Reconfiguration
Handover Command HO Time
Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
496
Chapter 2 Counter Description
Figure 342. Collection Time for Handover Time(Inter X2) UE
Source eNB
Target eNB
MME
S/GW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge Rrc Connection Reconfiguration
HO Time
Rrc Connection Reconfiguration Complete
Handover time statistics are based on the Target eNB. Intra handover time refers to the time taken from transmitting the RRC Connection Reconfiguration message to the UE until after receiving the RRC Connection Reconfiguration Complete message. Inter-X2 handover time refers to the time taken from after transmission of the X2 Handover Request Acknowledge message at the target eNB until receiving the RRC Connection Reconfiguration Complete message from the UE. Inter-X2 handover time refers to the time taken from after transmission of the S1 Handover Request Acknowledge message at the Target eNB until receiving the RRC Connection Reconfiguration Complete message from the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
497
Chapter 2 Counter Description
Outgoing Intra-Frequency Handover This section provides statistics on the Outgoing Intra-Frequency Handover. If the frequency is the same between the source and the target cells, the handover statistics are collected. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraFreqOut Att
count
The cumulated number of Outgoing intra-frequency handover attempt count
This counter is collected when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
Intra eNB: This counter is cumulated when the Intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the Inter X2 HO is judged in the HO decision based on the source cell when a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the Inter S1 HO is judged in the HO decision based on the source cell after a measurement report
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
498
Chapter 2 Counter Description Name
Unit
Description
Trigger
IntraFreqOut PrepSucc
count
The cumulated number of Outgoing intra-frequency handover preparation success count
This counter is collected when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
message is received from the UE.
Intra eNB: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after handover preparation to the target cell between the inner blocks is completed when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a handover request is transmitted to the target eNB and a handover request acknowledge message is received from the target eNB when inter X2 HO is judged in the HO decision after a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a S1 handover required message is transmitted to MME and a S1 handover command message is
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
499
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
received from MME when inter S1 HO is judged in the HO decision after a measurement report message is received from the UE. IntraFreqOut Succ
count
The cumulated number of Outgoing intra-frequency handover execution success count
This counter is cumulate when when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Intra eNB: This counter is cumulated when the target cell normally receives a RRC connection reconfiguration complete message from the UE after intra HO is executed.
Inter X2: This counter is cumulated when the source eNB normally receives an UE context release command message after inter X2 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
Inter S1: This counter is cumulated when the source eNB normally receives an UE context release command message after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
500
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB. IntraFreqOut PrepFail_Cp CcFail
count
The cumulated number when preparation fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated as follows when the frequency information is the same between the source eNB (cell) and target eNB (cell). This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) Handover preparation procedure. This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (Inter S1) handover preparation procedures. This counter is cumulated when a call is released since resource allocation in the ECCB fails during the intra eNB and inter X2 (inter S1) handover preparation procedures.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
501
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraFreqOut PrepFail_S1a pCuFail
count
The cumulated number when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut PrepFail_S1a pLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut PrepFail_S1a pRpTo
count
The cumulated number when preparation fails due to a timeout that has occurred when a S1 handover command message is not received from MME after the SeNB transmits a S1 handover required message to MME during the inter S1 HO preparation procedure when the frequency
This counter is cumulated when preparation fails due to a timeout that has occurred as a S1 handover command message is not received from MME after the SeNB transmits a S1 handover required message to MME during the inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
502
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
information is the same between the source eNB (cell) and target eNB (cell). IntraFreqOut PrepFail_S1a pSigFail
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated as follows when the frequency information is the same between the source eNB (cell) and target eNB (cell). This counter is cumulated when the eNB releases a call due receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO procedure. This counter is cumulated when the eNB releases a call due receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO procedure.
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut PrepFail_X2a pCuFail
count
The cumulated number when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request
This counter is cumulated when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
503
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
message to the target eNB during the inter X2 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell). IntraFreqOut PrepFail_X2a pLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut PrepFail_X2a pRpTo
count
The cumulated number when preparation fails due to a timeout that has occurred since the serving eNB transmits a handover request message to the target eNB and does not receive a handover request acknowledge message from the target eNB during the inter X2 HO preparation procedure when the frequency information is the same between the
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB transmits a handover request message to the target eNB and does not receive a handover request acknowledge message from the target eNB during the inter X2 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
504
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
source eNB (cell) and target eNB (cell). IntraFreqOut PrepFail_X2a pSigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_CpCcTo
count
The cumulated number of releases due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_CpCcFai l
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB,
This counter is cumulated as follows when the frequency information is the same between the source eNB (cell) and target eNB (cell). This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO execution procedure.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
505
Chapter 2 Counter Description Name
IntraFreqOut Fail_UpGtpF ail
Unit
count
Description
Trigger
inter X2 or inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) Handover execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of UE information during the intra eNB and inter X2 (inter S1) handover execution procedures. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) Handover execution procedure
The cumulated number when execution fails due to not receiving a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the
This counter is cumulated when execution fails due to not receiving a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
506
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
source eNB (cell) and target eNB (cell). IntraFreqOut Fail_UpMacF ail
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated as follows when the frequency information is the same between the source eNB (cell) and target eNB (cell). This counter is cumulated when execution fails since Fail is received as a response message from the MAC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_UpPdcp Fail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
507
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
source eNB (cell) and target eNB (cell). IntraFreqOut Fail_UpRlcFa il
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated as follows when the frequency information is the same between the source eNB (cell) and target eNB (cell). This counter is cumulated when execution fails since Fail is received as a response message from the RLC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_RrcSigF ail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_S1apCu Fail
count
The cumulated number of releases due to a S1AP specification cause that occurs during intra eNB, inter X2 or inter S1 HO execution when the frequency information is the
This counter is cumulated when a call is released due to a S1AP specification cause that occurs during intra eNB, inter X2 or inter S1 HO execution when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
508
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
same between the source eNB (cell) and target eNB (cell). IntraFreqOut Fail_S1apLin kFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated when execution fails since the S1AP link status is changed to 'Out of Service' during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_S1apRO To
count
The cumulated number of timeouts that occur during the inter S1 HO execution procedure when the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message
This counter is cumulated when the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message and timeouts occur during the inter S1 HO execution procedure.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
509
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message. IntraFreqOut Fail_S1apSig Fail
count
The cumulated number when execution fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
This counter is cumulated as follows when the frequency information is the same between the source eNB (cell) and target eNB (cell). This counter is cumulated when a call is released due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is released due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_X2apCu Fail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut Fail_X2apLin kFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
IntraFreqOut
count
The cumulated
This counter is cumulated when the
Y
CC
event
int
0~21
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
510
Chapter 2 Counter Description Name
Unit
Fail_X2apRo To
IntraFreqOut Fail_X2apSig Fail
count
Description
Trigger
number of timeouts that occur during the inter X2 HO execution procedure when the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message and timeouts occur during the inter X2 HO execution procedure
The cumulated number of releases due to receiving X2AP signaling during the inter X2 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB
This counter is cumulated when a call is released due to receiving X2AP signaling during the inter X2 HO execution procedure when the frequency information is the same between the source eNB (cell) and target eNB (cell).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 4748 3647
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
511
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
(cell).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
512
Chapter 2 Counter Description
Collection Time (Success) Figure 343. Collection Time for Outgoing Intra-Frequency HO (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn A)
UE moves to Inter eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision Resource Setup
② IntraFreqOutPrepSucc
Success
Rrc Connection Reconfiguration ③ IntraFreqOutSucc
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Rrc Connection Reconfiguration Complete
513
Chapter 2 Counter Description
Figure 344. Collection Time for Outgoing Intra-Frequency HO (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① IntraFreqOutAtt
Handover Request Acknowledge
② IntraFreqOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge ③ IntraFreqOutSucc
UE Context Release
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
514
Chapter 2 Counter Description
Figure 345. Collection Time for Outgoing Intra-Frequency HO (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
Handover Required
① IntraFreqOutAtt
Handover Request Handover Request Acknowledge
② IntraFreqOutPrepSucc
Handover Command
RRC Connection Reconfiguration eNB Status Transfer RRC Connection Reconfiguration Complete
MME Status Transfer Handover Notify
Tracking Area Update Procedure (NAS) UE Context Release Command ③ IntraFreqOutSucc
UE Context Release Complete
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
515
Chapter 2 Counter Description
Collection Time (Failure) Figure 346. Collection Time for IntraFreqOutPrepFail_CpCcFail (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn A)
UE moves to Inter eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision Resource Setup Success
Case 1.
ECMB reset
② Failure - IntraFreqOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - IntraFreqOutPrepFail_CpCcFail
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - IntraFreqOutPrepFail_CpCcFail
516
Chapter 2 Counter Description
Figure 347. Collection Time for IntraFreqOutPrepFail_CpCcFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Handover Request
Case 1.
ECMB reset
② Failure - IntraFreqOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - IntraFreqOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - IntraFreqOutPrepFail_CpCcFail
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
517
Chapter 2 Counter Description
Figure 348. Collection Time for IntraFreqOutPrepFail_CpCcFail (S1) Source eNB (earfcn A)
UE
EPC
Target eNB (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Handover Request Handover Request Handover Request Acknowledge
Case 1.
ECMB reset
② Failure - IntraFreqOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - IntraFreqOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - IntraFreqOutPrepFail_CpCcFail
Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
518
Chapter 2 Counter Description
Figure 349. Collection Time for IntraFreqOutPrepFail_S1apCuFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
② Failure - IntraFreqOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
519
Chapter 2 Counter Description
Figure 350. Collection Time for IntraFreqOutPrepFail_S1apCuFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND
② Failure - IntraFreqOutPrepFaill_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
520
Chapter 2 Counter Description
Figure 351. Collection Time for IntraFreqOutPrepFail_S1apCuFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
Handover Required
① IntraFreqOutAtt
Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND
② Failure - IntraFreqOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
521
Chapter 2 Counter Description
Figure 352. Collection Time for IntraFreqOutPrepFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision Resource Setup Success S1AP Link is Out of Service Status
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - IntraFreqOutPrepFail_S1apLinkFail
SCTB reset
② Failure - IntraFreqOutPrepFail_S1apLinkFail
522
Chapter 2 Counter Description
Figure 353. Collection Time for IntraFreqOutPrepFail_S1apLinkFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Handover Request S1AP Link is Out of Service Status
Case 1.
Case 2.
② Failure - IntraFreqOutPrepFail_S1apLinkFail
SCTB reset
② Failure - IntraFreqOutPrepFail_S1apLinkFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
523
Chapter 2 Counter Description
Figure 354. Collection Time for IntraFreqOutPrepFail_S1apLinkFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledge S1AP Link is Out of Service Status Case 1. ② Failure - IntraFreqOutPrepFail_S1apLinkFail
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
SCTB reset
② Failure - IntraFreqOutPrepFail_S1apLinkFail
524
Chapter 2 Counter Description
Figure 355. Collection Time for IntraFreqOutPrepFail_S1apRpTo EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
Handover Required
① IntraFreqOutAtt Handover Request Handover Request Acknowledge
Timeout
Handover Command
X
② Failure - IntraFreqOutPrepFail_S1apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
525
Chapter 2 Counter Description
Figure 356. Collection Time for IntraFreqOutPrepFail_S1apSigFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
Case 1.
② Failure - IntraFreqOutPrepFail_S1apSigFail
S1AP RESET Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - IntraFreqOutPrepFail_S1apSigFail
526
Chapter 2 Counter Description
Figure 357. Collection Time for IntraFreqOutPrepFail_S1apSigFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Handover Request S1AP UE CONTEXT RELEASE COMMAND
Case 1.
② Failure - IntraFreqOutPrepFail_S1apSigFail
S1AP RESET Case 2.
② Failure - IntraFreqOutPrepFail_S1apSigFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
527
Chapter 2 Counter Description
Figure 358. Collection Time for IntraFreqOutPrepFail_S1apSigFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND Case 1.
② Failure - IntraFreqOutPrepFail_S1apSigFail
S1AP RESET Case 2.
② Failure - IntraFreqOutPrepFail_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
528
Chapter 2 Counter Description
Figure 359. Collection Time for IntraFreqOutPrepFail_X2apCuFail Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① IntraFreqOutAtt Handover Preparation Failure ② Failure - IntraFreqOutPrepFail_X2apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
529
Chapter 2 Counter Description
Figure 360. Collection Time for IntraFreqOutPrepFail_X2apRpTo Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① IntraFreqOutAtt Time out
Handover Request Acknowledge
X
② Fail - IntraFreqOutPrepFail_X2apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
530
Chapter 2 Counter Description
Figure 361. Collection Time for IntraFreqOutFail_CpCcTo (Intra eNB) eNB Source Cell ECCB (earfcn A)
Source Cell PDCP/RLC
UE
Target Cell (earfcn A)
UE moves to Intra eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision
Resource Setup ② IntraFreqOutPrepSucc
Success
Rrc Connection Reconfiguration Re-establish control Success X Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Timer Internal Reestablish Control ③ Failure - IntraFreqOutFail_CpCcTo
531
Chapter 2 Counter Description
Figure 362. Collection Time for IntraFreqOutFail_CpCcTo (X2) UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt ② IntraFreqOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer Forward Path Setup Case 1.
Success Message X
③ Failure - IntraFreqOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - IntraFreqOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
532
Chapter 2 Counter Description
Figure 363. Collection Time for IntraFreqOutFail_CpCcTo (S1) UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
Handover Required
① IntraFreqOutAtt
Handover Request Acknowledge Handover Command
② IntraFreqOutPrepSucc RRC Connection Reconfiguration Forward Path Setup Case 1.
Success Message X
③ Failure - IntraFreqOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - IntraFreqOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
533
Chapter 2 Counter Description
Figure 364. Collection Time for IntraFreqOutFail_CpCcFail (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn A)
UE moves to Intra eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision Resource Setup
② IntraFreqOutPrepSucc
Success
RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - IntraFreqOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - IntraFreqOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - IntraFreqOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
534
Chapter 2 Counter Description
Figure 365. Collection Time for IntraFreqOutFail_CpCcFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt ② IntraFreqOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Case 1.
ECMB reset
② Failure - IntraFreqOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - IntraFreqOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - IntraFreqOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
535
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
536
Chapter 2 Counter Description Figure 366. Collection Time for IntraFreqOutFail_CpCcFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt
Handover Required Handover Request Handover Request Acknowledge Handover Command
② IntraFreqOutPrepSucc RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - IntraFreqOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - IntraFreqOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - IntraFreqOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
537
Chapter 2 Counter Description
Figure 367. Collection Time for IntraFreqOutFail_UpGtpFail (X2) Source eNB (earfcn A)
UE
GTP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① IntraFreqOutAtt
Handover Request Handover Request Acknowledge
② IntraFreqOutPrepSucc RRC Connection Reconfiguration
Forward Path Setup Fail Message
③ Failure - IntraFreqOutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
538
Chapter 2 Counter Description
Figure 368. Collection Time for IntraFreqOutFail_UpGtpFail (S1) Source eNB (earfcn A)
UE
GTP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
Handover Required
① IntraFreqOutAtt Handover Request Handover Request Acknowledge Handover Command
② IntraFreqOutPrepSucc RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - IntraFreqOutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
539
Chapter 2 Counter Description
Figure 369. Collection Time for IntraFreqOutFail_UpMacFail eNB Source Cell PDCP/RLC
UE
Source Cell ECCB (earfcn A)
Target Cell (earfcn A)
UE moves to Intra eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision
② IntraFreqOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Success A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
③ Failure - IntraFreqOutFail_UpMacFail
540
Chapter 2 Counter Description
Figure 370. Collection Time for IntraFreqOutFail_UpPdcpFail (X2) Source eNB (earfcn A)
UE
PDCP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision ① IntraFreqOutAtt
Handover Request Handover Request Acknowledge
② IntraFreqOutPrepSucc RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - IntraFreqOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
541
Chapter 2 Counter Description
Figure 371. Collection Time for IntraFreqOutFail_UpPdcpFail (S1) Source eNB (earfcn A)
UE
PDCP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledge ② IntraFreqOutPrepSucc
Handover Command
RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - IntraFreqOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
542
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
543
Chapter 2 Counter Description Figure 372. Collection Time for IntraFreqOutFail_UpRlcFail (Intra eNB) eNB Source Cell ECCB (earfcn A)
Source Cell RLC
UE
Target Cell (earfcn A)
UE moves to Intra eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision
② IntraFreqOutPrepSucc
Resource Setup Success
Rrc Connection Reconfiguration Re-establish control Case 1. Fail Message
Case 2.
③ Failure - IntraFreqOutFail_UpRlcFail
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - IntraFreqOutFail_UpRlcFail
Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
544
Chapter 2 Counter Description Figure 373. Collection Time for IntraFreqOutFail_UpRlcFail (X2) Source eNB (earfcn A)
UE
RLC
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① IntraFreqOutAtt
Handover Request Handover Request Acknowledge
② IntraFreqOutPrepSucc RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - IntraFreqOutFail_UpRlcFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
545
Chapter 2 Counter Description
Figure 374. Collection Time for IntraFreqOutFail_UpRlcFail (S1) Source eNB (earfcn A)
UE
RLC
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledge ② IntraFreqOutPrepSucc
Handover Command
RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - IntraFreqOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
546
Chapter 2 Counter Description
Figure 375. Collection Time for IntraFreqOutFail_S1apCuFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn A)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① IntraFreqOutAtt
HO Decision
② IntraFreqOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration S1AP UE CONTEXT RELEASE COMMAND ③ Failure - IntraFreqOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
547
Chapter 2 Counter Description
Figure 376. Collection Time for IntraFreqOutFail_S1apCuFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt ② IntraFreqOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND ③ Failure - IntraFreqOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
548
Chapter 2 Counter Description
Figure 377. Collection Time for IntraFreqOutFail_S1apCuFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① IntraFreqOutAtt
Handover Request Handover Request Acknowledge
② IntraFreqOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer MME Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - IntraFreqOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
549
Chapter 2 Counter Description
Figure 378. Collection Time for IntraFreqOutFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn A)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① IntraFreqOutAtt
② IntraFreqOutPrepSucc
HO Decision Resource Setup Success
RRC Connection Reconfiguration S1AP Link is Out of Service Status Case 1.
Case 2.
② Failure - IntraFreqOutFail_S1apLinkFail
SCTB reset
② Failure - IntraFreqOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
550
Chapter 2 Counter Description
Figure 379. Collection Time for IntraFreqOutFail_S1apLinkFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① IntraFreqOutAtt ② IntraFreqOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Case 1.
S1AP Link is Out of Service Status ③ Failure - IntraFreqOutFail_S1apLinkFail
SCTB reset
Case 2.
③ Failure - IntraFreqOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
551
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
552
Chapter 2 Counter Description Figure 380. Collection Time for IntraFreqOutFail_S1apLinkFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledge ② IntraFreqOutPrepSucc Handover Command RRC Connection Reconfiguration eNB Status Transfer
MME Status Transfer
S1AP Link is Out of Service Status Case 1.
③ Failure - IntraFreqOutFail_S1apLinkFail
SCTB reset
Case 2.
③ Failure - IntraFreqOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
553
Chapter 2 Counter Description Figure 381. Collection Time for IntraFreqOutFail_S1apROTo UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn A)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledge ② IntraFreqOutPrepSucc
Handover Command
RRC Connection Reconfiguration eNB Status Transfer Timer RelocOverall
MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command ③ Failure - IntraFreqOutFail_S1apROTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
554
Chapter 2 Counter Description
Figure 382. Collection Time for IntraFreqOutFail_S1apSigFail (X2) Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request ① IntraFreqOutAtt ② IntraFreqOutPrepSucc
Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND Case 1.
③ Failure - IntraFreqOutFail_S1apSigFail
S1AP RESET Case 2.
③ Failure - IntraFreqOutFail_S1apSigFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
555
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
556
Chapter 2 Counter Description Figure 383. Collection Time for IntraFreqOutFail_S1apSigFail (S1) EPC
Target eNB (earfcn A)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① IntraFreqOutAtt Handover Request Handover Request Acknowledg Handover Command
② IntraFreqOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer
MME Status Transfer
S1AP UE CONTEXT RELEASE COMMAND Case 1.
③ Failure - IntraFreqOutFail_S1apSigFail
S1AP RESET Case 2.
③ Failure - IntraFreqOutFail_S1apSigFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
557
Chapter 2 Counter Description Figure 384. Collection Time for IntraFreqOutFail_X2apRoTo Target eNB (earfcn A)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge
① IntraFreqOutAtt ② IntraFreqOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer
Timerout X2relocOverall
HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release X ③ Failure - IntraFreqOutFail_X2apRoTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
558
Chapter 2 Counter Description
Outgoing Inter-Frequency Handover with Measurement Gap This section provides statistics on the Outgoing Inter-Frequency Handover with Measurement Gap. The handover statistics is collected if the frequency information between source and target is different and measurement gap is used. Index Name
Description
cNum
Cell Id
TargetEarfcnDl
Target neighbor cell frequency (EARFCN DL)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutAtt
cou nt
The cumulated number of outgoing inter-frequency handover (measurement gap assisted) attempt count
This counter is collected when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Y
CC
event
int
0~2 147 483 647
-
-
Intra eNB: This counter is cumulated when the Intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the Inter X2 HO is judged in the HO decision based on the source cell when a measurement report message is received from the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
559
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
Inter S1: This counter is cumulated when the Inter S1 HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE. InterFreq MeasGap OutPrepS ucc
cou nt
The cumulated number of outgoing inter-frequency handover (measurement gap assisted) preparation success count
This counter is collected when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. Intra eNB: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after handover preparation to the target cell between the inner blocks is completed when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a handover request is transmitted to the
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
560
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
target eNB and a handover request acknowledge message is received from the target eNB when inter X2 HO is judged in the HO decision after a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a S1 handover required message is transmitted to MME and a S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after a measurement report message is received from the UE. InterFreq MeasGap OutSucc
cou nt
The cumulated number of outgoing inter-frequency handover (measurement gap assisted) execution success count
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is collected when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. Intra eNB: This counter is cumulated when the target cell normally receives a RRC connection reconfiguration complete message from the UE after intra HO is executed.
561
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
Inter X2: This counter is cumulated when the source eNB normally receives an UE context release command message after inter X2 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
Inter S1: This counter is cumulated when the source eNB normally receives an UE context release command message after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB. InterFreq MeasGap OutPrepF ail_CpCc
cou nt
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target
562
Chapter 2 Counter Description Name
Unit
Fail
InterFreq MeasGap
cou
Description
Trigger
ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
eNB (cell) and the measurement gap is used. This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of UE information during the intra eNB and inter X2 (inter S1) HO preparation procedures. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO preparation procedure
The cumulated number when execution fails since a S1AP
This counter is cumulated when execution fails since a S1AP
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147
-
563
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 483 647
Granularity Formula
Hourly, Daily, Monthly Formula
OutPrepF ail_S1ap CuFail
nt
specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
InterFreq MeasGap OutPrepF ail_S1ap LinkFail
cou nt
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutPrepF ail_S1ap RpTo
cou nt
The cumulated number when preparation fails due to a timeout that has occurred when a S1 handover command message is not received from MME after the SeNB transmits a S1 handover required message to MME during the inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
This counter is cumulated when preparation fails due to a timeout that has occurred when a S1 handover command message is not received from MME after the SeNB transmits a S1 handover required message to MME during the inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutPrepF ail_S1ap SigFail
cou nt
The cumulated number when preparation fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET message is received from MME during the intra eNB, inter X2 or inter S1 HO
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. This counter is cumulated when
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
564
Chapter 2 Counter Description Name
Unit
Description
Trigger
preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
a call is released due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated when a call is released due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutPrepF ail_X2ap CuFail
cou nt
The cumulated number when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
This counter is cumulated when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutPrepF ail_X2ap LinkFail
cou nt
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutPrepF
cou nt
The cumulated number when preparation fails due to a timeout that has occurred
This counter is cumulated when preparation fails due to a timeout that has occurred since the
Y
CC
event
int
0~2 147 483
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
565
Chapter 2 Counter Description Name
Unit
ail_X2ap RpTo
Description
Trigger
since the serving eNB transmits a handover request message to the target eNB and does not receive a handover request acknowledge message from the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
serving eNB transmits a handover request message to the target eNB and does not receive a handover request acknowledge message from the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 647
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutPrepF ail_X2ap SigFail
cou nt
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_ CpCcTo
cou nt
The cumulated number of releases due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_ CpCcFail
cou nt
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
566
Chapter 2 Counter Description Name
InterFreq MeasGap OutFail_
Unit
cou nt
Description
Trigger
ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
eNB (cell) and the measurement gap is used. This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO execution procedure
The cumulated number when execution fails since Fail is received as a response
This counter is cumulated when execution fails since Fail is received as a response message
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483
-
-
567
Chapter 2 Counter Description Name
Unit
UpGtpFai l
Description
Trigger
message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 647
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutFail_ UpMacFa il
cou nt
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. This counter is cumulated when execution fails since Fail is received as a response message from the MAC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_ UpPdcpF ail
cou nt
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
568
Chapter 2 Counter Description Name
Unit
Description
Trigger
or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutFail_ UpRlcFail
cou nt
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. This counter is cumulated when execution fails since Fail is received as a response message from the RLC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_ RrcSigFai l
cou nt
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq
cou
The cumulated number of
This counter is cumulated when
Y
CC
event
int
0~2
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
569
Chapter 2 Counter Description Name
Unit
Description
Trigger
MeasGap OutFail_ S1apCuF ail
nt
releases due to a S1AP specification cause that occurs during intra eNB, inter X2 or inter S1 HO execution when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
a call is released due to a S1AP specification cause that occurs during intra eNB, inter X2 or inter S1 HO execution when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
InterFreq MeasGap OutFail_ S1apLink Fail
cou nt
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
InterFreq MeasGap OutFail_ S1apRoT o
cou nt
The cumulated number of timeouts that occur during the inter S1 HO execution procedure when the frequency information is different between the source eNB (cell)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 147 483 647
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. This counter is cumulated when the eNB releases the call because the status of the callrelated S1AP link has been changed to OOS (Out Of Service) during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is release due to SCTB reset during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Y
CC
event
int
0~2 147 483 647
-
-
This counter is cumulated when timeouts occurs during the inter S1 HO execution procedure as the frequency information is different between the source eNB (cell) and target eNB (cell)
Y
CC
event
int
0~2 147 483 647
-
-
570
Chapter 2 Counter Description Name
Unit
Description
Trigger
and target eNB (cell) and the measurement gap is used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
and the measurement gap is used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutFail_ S1apSigF ail
cou nt
The cumulated number when preparation fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET message is received from MME during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used.
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used. This counter is cumulated when the eNB releases a call due to receiving an S1AP UE CONTEXT RELEASE COMMANDduring Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when the eNB releases a call due to receiving an S1AP reset during Intra eNB, Inter X2 (Inter S1) procedure.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_
cou nt
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
571
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 647
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreq MeasGap OutFail_ X2apLink Fail
cou nt
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_ X2apRoT o
cou nt
The cumulated number of timeouts that occur during the inter X2 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
This counter is cumulated when timeouts occurs during the inter X2 HO execution procedure as the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
Y
CC
event
int
0~2 147 483 647
-
-
InterFreq MeasGap OutFail_ X2apSigF ail
cou nt
The cumulated number of releases due to receiving X2AP signaling during the inter X2 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the
This counter is cumulated when a call is released due to receiving X2AP signaling during the inter X2 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement
Y
CC
event
int
0~2 147 483 647
-
-
X2apCuF ail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
572
Chapter 2 Counter Description Name
Unit
InterFreq OutWithG apCnt
cou nt
InterFreq OutWithG apTarget EarfcnDL
Targ etEa rfcn Dl
Description
Trigger
measurement gap is used.
gap is used.
The cumulated collection count of Outgoing Inter-frequency Handover with Measurement Gap The TargetEarfcnDl which collection is requested
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated by 1 when InterFreqOutWithGap is collected
-
CC
event
int
0~2 147 483 647
-
-
This counter is calculated when measurement period comes.
-
OW
event
int
0~2 147 483 647
-
-
573
Chapter 2 Counter Description
Collection Time Figure 385. Collection Time for Outgoing Inter-Frequency HO with Measurement Gap (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
② InterFreqMeasGapOutPrepSucc
HO Decision Resource Setup Success
RRC Connection Reconfiguration ③ InterFreqMeasGapOutSucc
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
RRC Connection Reconfiguration Complete
574
Chapter 2 Counter Description Figure 386. Collection Time for Outgoing Inter-Frequency HO with Measurement Gap (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterFreqMeasGapOutAtt
Handover Request Acknowledge
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge ③ InterFreqMeasGapOutSucc
UE Context Release
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
575
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
576
Chapter 2 Counter Description Figure 387. Collection Time for Outgoing Inter-Frequency HO with Measurement Gap (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge
② InterFreqMeasGapOutPrepSucc
Handover Command
RRC Connection Reconfiguration
eNB Status Transfer MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify
Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete ③ InterFreqMeasGapOutSucc Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
577
Chapter 2 Counter Description
Figure 388. Collection Time for InterFreqMeasGapOutPrepFail_S1apCpCcFail (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision Resource Setup Success
Case 1.
ECMB reset
② Failure - InterFreqMeasGapOutPrepFail_CpCcFaill
Case 2.
Cell disabled
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
578
Chapter 2 Counter Description
Figure 389. Collection Time for InterFreqMeasGapOutPrepFail_S1apCpCcFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt
Handover Request
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
Case 1.
ECMB reset
Case 2.
Cell disabled
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
579
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
580
Chapter 2 Counter Description Figure 390. Collection Time for InterFreqMeasGapOutPrepFail_S1apCpCcFail (S1) UE
Source eNB (earfcn A)
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
Case 1.
ECMB reset
Case 2.
Cell disabled
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
② Failure - InterFreqMeasGapOutPrepFail_CpCcFail
Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
581
Chapter 2 Counter Description
Figure 391. Collection Time for InterFreqMeasGapOutPrepFail_S1apCuFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
② Failure - InterFreqMeasGapOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
582
Chapter 2 Counter Description
Figure 392. Collection Time for InterFreqMeasGapOutPrepFail_S1apCuFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt
Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND
② Failure - InterFreqMeasGapOutPrepFail_S1apCuFail Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
583
Chapter 2 Counter Description
Figure 393. Collection Time for InterFreqMeasGapOutPrepFail_S1apCuFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND ② Failure - InterFreqMeasGapOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
584
Chapter 2 Counter Description
Figure 394. Collection Time for InterFreqMeasGapOutPrepFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision Resource Setup Success S1AP Link is Out of Service Status
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqMeasGapOutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterFreqMeasGapOutPrepFail_S1apLinkFail
585
Chapter 2 Counter Description
Figure 395. Collection Time for InterFreqMeasGapOutPrepFail_S1apLinkFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt
Handover Request S1AP Link is Out of Service Status
Case 1.
Case 2.
② Failure - InterFreqMeasGapOutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterFreqMeasGapOutPrepFail_S1apLinkFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
586
Chapter 2 Counter Description
Figure 396. Collection Time for InterFreqMeasGapOutPrepFail_S1apLinkFail (S1) UE
Source eNB (earfcn A)
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge S1AP Link is Out of Service Status Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqMeasGapOutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterFreqMeasGapOutPrepFail_S1apLinkFail
587
Chapter 2 Counter Description
Figure 397. Collection Time for InterFreqMeasGapOutPrepFail_S1apRpTo Source eNB (earfcn A)
UE
Target eNB (earfcn B)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Timeout
Handover Request Handover Request Acknowledge Handover Command
X ② Failure - InterFreqMeasGapOutPrepFail_S1apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
588
Chapter 2 Counter Description
Figure 398. Collection Time for InterFreqMeasGapOutPrepFail_S1apSigFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
Case 1.
② Failure - InterFreqMeasGapOutPrepFail_S1apSigFail
S1AP RESET Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqMeasGapOutPrepFail_S1apSigFail
589
Chapter 2 Counter Description
Figure 399. Collection Time for InterFreqMeasGapOutPrepFail_S1apSigFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt
Handover Request S1AP UE CONTEXT RELEASE COMMAND
Case 1.
② Failure - InterFreqMeasGapOutPrepFail_S1apSigFail
S1AP RESET Case 2.
② Failure - InterFreqMeasGapOutPrepFail_S1apSigFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
590
Chapter 2 Counter Description
Figure 400. Collection Time for InterFreqMeasGapOutPrepFail_S1apSigFail (S1) UE
Source eNB (earfcn A)
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge
S1AP UE CONTEXT RELEASE COMMAND Case 1.
② Failure - InterFreqMeasGapOutPrepFail_S1apSigFail
S1AP RESET Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqMeasGapOutPrepFail_S1apSigFail
591
Chapter 2 Counter Description Figure 401. Collection Time for InterFreqMeasGapOutPrepFail_X2apCuFail Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt
Handover Request Handover Preparation Failure
② Failure - InterFreqMeasGapOutPrepFail_X2apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
592
Chapter 2 Counter Description Figure 402. Collection Time for InterFreqMeasGapOutPrepFail_X2apRpTo UE
Source eNB (earfcn A)
Target eNB (earfcn B)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt Time out
Handover Request Handover Request Acknowledge X
② Fail - InterFreqMeasGapOutPrepFail_X2apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
593
Chapter 2 Counter Description
Figure 403. Collection Time for InterFreqMeasGapOutFail_CpCcTo-Intra eNB eNB Source Cell PDCP/RLC
UE
Source Cell ECCB (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision
② InterFreqMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Timer Internal Reestablish Control Success X RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
③ Failure - InterFreqMeasGapOutFail_CpCcTo
594
Chapter 2 Counter Description
Figure 404. Collection Time for InterFreqMeasGapOutFail_CpCcTo (X2) UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① InterFreqMeasGapOutAtt
Handover Request Handover Request Acknowledge
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration SN Status Transfer
Forward Path Setup Case 1.
Success Message X
③ Failure - InterFreqMeasGapOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - InterFreqMeasGapOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
595
Chapter 2 Counter Description Figure 405. Collection Time for InterFreqMeasGapOutFail_CpCcTo (S1) UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge Handover Command ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration Forward Path Setup Case 1.
Success Message X
③ Failure - InterFreqMeasGapOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - InterFreqMeasGapOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
596
Chapter 2 Counter Description
Figure 406. Collection Time for InterFreqMeasGapOutFail_CpCcFail (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision
② InterFreqMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - InterFreqMeasGapOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqMeasGapOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqMeasGapOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
597
Chapter 2 Counter Description
Figure 407. Collection Time for InterFreqMeasGapOutFail_CpCcFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer
Case 1.
ECMB reset
② Failure - InterFreqMeasGapOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqMeasGapOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqMeasGapOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
598
Chapter 2 Counter Description
Figure 408. Collection Time for InterFreqMeasGapOutFail_CpCcFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge ② InterFreqMeasGapOutPrepSucc
Handover Command
RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - InterFreqMeasGapOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqMeasGapOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqMeasGapOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
599
Chapter 2 Counter Description
Figure 409. Collection Time for InterFreqMeasGapOutFail_UpGtpFail (X2) Source eNB (earfcn A)
UE
GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Request ① InterFreqMeasGapOutAtt Handover Request Acknowledge ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Forward Path Setup Fail Message
③ Failure - InterFreqMeasGapOutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
600
Chapter 2 Counter Description Figure 410. Collection Time for InterFreqMeasGapOutFail_UpGtpFail (S1) Source eNB (earfcn A)
UE
GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge Handover Command
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Forward Path Setup Fail Message ③ Failure - InterFreqMeasGapOutFail_UpGtpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
601
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
602
Chapter 2 Counter Description Figure 411. Collection Time for InterFreqMeasGapOutFail_UpMacFail eNB Source Cell ECCB (earfcn A)
Source Cell PDCP/RLC
UE
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision
② InterFreqMeasGapOutPrepSucc
Resource Setup Success
Rrc Connection Reconfiguration Re-establish control Success A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - InterFreqMeasGapOutFail_UpMacFail Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
603
Chapter 2 Counter Description
Figure 412. Collection Time for InterFreqMeasGapOutFail_UpPdcpFail (X2) Source eNB (earfcn A)
UE
PDCP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Request ① InterFreqMeasGapOutAtt Handover Request Acknowledge ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Exec Fail Message
③ Failure - InterFreqMeasGapOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
604
Chapter 2 Counter Description
Figure 413. Collection Time for InterFreqMeasGapOutFail_UpPdcpFail (S1) Source eNB (earfcn A)
UE
PDCP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Required ① InterFreqMeasGapOutAtt
Handover Request Handover Request Acknowledge Handover Command
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Exec Fail Message
③ Failure - InterFreqMeasGapOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
605
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
606
Chapter 2 Counter Description Figure 414. Collection Time for InterFreqMeasGapOutFail_UpRlcFail (Intra eNB) eNB Source Cell ECCB (earfcn A)
Source Cell RLC
UE
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision
② InterFreqMeasGapOutPrepSucc
Resource Setup Success
Rrc Connection Reconfiguration Re-establish control Case 1. Fail Message
Case 2.
③ Failure - InterFreqMeasGapOutFail_UpRlcFail
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - InterFreqMeasGapOutFail_UpRlcFail
Rrc Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
607
Chapter 2 Counter Description Figure 415. Collection Time for InterFreqMeasGapOutFail_UpRlcFail (X2) Source eNB (earfcn A)
UE
RLC
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① InterFreqMeasGapOutAtt
Handover Request Handover Request Acknowledge
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Re-establish Fail Message
③ Failure - InterFreqMeasGapOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
608
Chapter 2 Counter Description
Figure 416. Collection Time for InterFreqMeasGapOutFail_UpRlcFail (S1) Source eNB (earfcn A)
UE
RLC
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge Handover Command ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Re-establish Fail Message
③ Failure - InterFreqMeasGapOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
609
Chapter 2 Counter Description Figure 417. Collection Time for InterFreqMeasGapOutFail_S1apCuFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt
HO Decision
② InterFreqMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration S1AP UE CONTEXT RELEASE COMMAND ③ Failure - InterFreqMeasGapOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
610
Chapter 2 Counter Description
Figure 418. Collection Time for InterFreqMeasGapOutFail_S1apCuFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt ② InterFreqMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND ③ Failure - InterFreqMeasGapOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
611
Chapter 2 Counter Description
Figure 419. Collection Time for InterFreqMeasGapOutFail_S1apCuFail (S1) UE
EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge Handover Command ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer MME Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - InterFreqMeasGapOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
612
Chapter 2 Counter Description
Figure 420. Collection Time for InterFreqMeasGapOutFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqMeasGapOutAtt HO Decision
② InterFreqMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration
S1AP Link is Out of Service Status Case 1.
Case 2.
② Failure - InterFreqMeasGapOutFail_S1apLinkFail
SCTB reset
② Failure - InterFreqMeasGapOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
613
Chapter 2 Counter Description
Figure 421. Collection Time for InterFreqMeasGapOutFail_S1apLinkFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer S1AP Link is Out of Service Status Case 1.
Case 2.
③ Failure - InterFreqMeasGapOutFail_S1apLinkFail
SCTB reset
③ Failure - InterFreqMeasGapOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
614
Chapter 2 Counter Description
Figure 422. Collection Time for InterFreqMeasGapOutFail_S1apLinkFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer
MME Status Transfer
S1AP Link is Out of Service Status Case 1.
Case 2.
③ Failure - InterFreqMeasGapOutFail_S1apLinkFail
SCTB reset
③ Failure - InterFreqMeasGapOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
615
Chapter 2 Counter Description
Figure 423. Collection Time for InterFreqMeasGapOutFail_S1apRoTo UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledge Handover Command
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer Timer RelocOverall
MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command ③ Failure - InterFreqMeasGapOutFail_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
616
Chapter 2 Counter Description
Figure 424. Collection Time for InterFreqMeasGapOutFail_S1apSigFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqMeasGapOutAtt
Handover Request Handover Request Acknowledge
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND Case 1.
③ Failure - InterFreqMeasGapOutFail_S1apSigFail
S1AP RESET Case 2.
③ Failure - InterFreqMeasGapOutFail_S1apSigFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
617
Chapter 2 Counter Description
Figure 425. Collection Time for InterFreqMeasGapOutFail_S1apSigFail (S1) UE
EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqMeasGapOutAtt Handover Request Handover Request Acknowledg Handover Command ② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration eNB Status Transfer
MME Status Transfer
S1AP UE CONTEXT RELEASE COMMAND Case 1.
③ Failure - InterFreqMeasGapOutFail_S1apSigFail
S1AP RESET Case 2.
③ Failure - InterFreqMeasGapOutFail_S1apSigFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
618
Chapter 2 Counter Description
Figure 426. Collection Time for InterFreqMeasGapOutFail_X2apRoTo UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterFreqMeasGapOutAtt
Handover Request Acknowledge
② InterFreqMeasGapOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer
Timerout X2relocOverall
HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release X ③ Failure - InterFreqMeasGapOutFail_X2apRoTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
619
Chapter 2 Counter Description
Outgoing Inter-Frequency Handover without Measurement Gap This section provides statistics on the Outgoing Inter-Frequency Handover without Measurement Gap. The handover statistics are collected if the frequency is different between the source and the target cells, and the measurement gap is not used. Index Name
Description
cNum
Cell Id
TargetEarfcnDl
Target neighbor cell frequency (EARFCN DL)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreqNoMe asGapOutAtt
count
The cumulated number of outgoing inter-frequency handover (no measurement gap assisted) attempt count
This counter is collected when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. Intra eNB: This counter is cumulated when the Intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE. Inter X2: This counter is cumulated when the Inter X2 HO is judged in the HO decision based on the source cell when a measurement report message is received from
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
620
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
the UE.
Inter S1: This counter is cumulated when the Inter S1 HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE. InterFreqNoMe asGapOutPrep Succ
count
The cumulated number of outgoing inter-frequency handover (no measurement gap assisted) preparation success count
This counter is collected when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Intra eNB: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after handover preparation to the target cell between the inner blocks is completed when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
621
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
completed after a handover request is transmitted to the target eNB and a handover request acknowledge message is received from the target eNB when inter X2 HO is judged in the HO decision after a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a S1 handover required message is transmitted to MME and a S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after a measurement report message is received from the UE. InterFreqNoMe asGapOutSucc
count
The cumulated number of outgoing inter-frequency handover (no measurement gap assisted) execution success count
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is collected when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Intra eNB: This counter is cumulated when the target
622
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
cell normally receives a RRC connection reconfiguration complete message from the UE after intra HO is executed.
Inter X2: This counter is cumulated when the source eNB normally receives an UE context release command message after inter X2 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
Inter S1: This counter is cumulated when the source eNB normally receives an UE context release command message after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
623
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
message from the UE, and an UE context release command message is transmitted to the source eNB. InterFreqNoMe asGapOutPrep Fail_CpCcFail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRVCELL-STS) is changed to disabled during Intra eNB, Inter X2 (S1) HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of UE information during the intra eNB and
624
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
inter X2 (inter S1) HO preparation procedures. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO preparation procedure InterFreqNoMe asGapOutPrep Fail_S1apCuF ail
count
The cumulated number when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutPrep Fail_S1apLink Fail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutPrep Fail_S1apRpT
count
The cumulated number when preparation fails due to a timeout that has
This counter is cumulated when preparation fails due to a timeout that has occurred when a S1 handover command
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
625
Chapter 2 Counter Description Name
Unit
o
InterFreqNoMe asGapOutPrep Fail_S1apSigF ail
count
Description
Trigger
occurred when a S1 handover command message is not received from MME after the SeNB transmits a S1 handover required message to MME during the inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
message is not received from MME after the SeNB transmits a S1 handover required message to MME during the inter S1 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
The cumulated number when preparation fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET message is received from MME during the intra eNB, inter X2 or inter S1 HO preparation procedure when the frequency information is
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when a call is released due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
626
Chapter 2 Counter Description Name
Unit
Description
Trigger
different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
when a call is released due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreqNoMe asGapOutPrep Fail_X2apCuF ail
count
The cumulated number when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutPrep Fail_X2apLink Fail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
627
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreqNoMe asGapOutPrep Fail_X2apRpT o
count
The cumulated number when preparation fails due to a timeout that has occurred since the serving eNB transmits a handover request message to the target eNB and does not receive a handover request acknowledge message from the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB transmits a handover request message to the target eNB and does not receive a handover request acknowledge message from the target eNB during the inter X2 HO preparation procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutPrep Fail_X2apSigF ail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutFail_ CpCcTo
count
The cumulated number of releases due to a timeout that has occurred since
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
628
Chapter 2 Counter Description Name
InterFreqNoMe asGapOutFail_ CpCcFail
Unit
count
Description
Trigger
a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
not received after a call control message is transmitted to the inner block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
629
Chapter 2 Counter Description Name
InterFreqNoMe asGapOutFail_ UpGtpFail
Unit
count
Description
Trigger
eNB (cell) and the measurement gap is not used.
CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO execution procedure
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
630
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
(cell) and target eNB (cell) and the measurement gap is not used. InterFreqNoMe asGapOutFail_ UpMacFail
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when execution fails since Fail is received as a response message from the MAC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutFail_ UpPdcpFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
631
Chapter 2 Counter Description Name
Unit
Description
Trigger
or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterFreqNoMe asGapOutFail_ UpRlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when execution fails since Fail is received as a response message from the RLC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutFail_
count
This counter is not collected in the
None
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
632
Chapter 2 Counter Description Name
Unit
RrcSigFail
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
system
InterFreqNoMe asGapOutFail_ S1apCuFail
count
The cumulated number of releases due to a S1AP specification cause that occurs during intra eNB, inter X2 or inter S1 HO execution when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated when a call is released due to a S1AP specification cause that occurs during intra eNB, inter X2 or inter S1 HO execution when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutFail_ S1apLinkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
This counter is cumulated as follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Intra eNB, Inter X2 (Inter S1) HO execution Procedure This counter is cumulated when a call is release due to SCTB reset during Intra eNB,
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
633
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Inter X2 (Inter S1) HO execution procedure InterFreqNoMe asGapOutFail_ S1apRoTo
count
The cumulated number of timeouts that occur during the inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
This counter is collected when timeouts occur during the inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe
count
The cumulated
This counter is cumulated as
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
634
Chapter 2 Counter Description Name
Unit
asGapOutFail_ S1apSigFail
Description
Trigger
number when preparation fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET message is received from MME during the intra eNB, inter X2 or inter S1 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
follows when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used. This counter is cumulated when a call is released due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is released due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
InterFreqNoMe asGapOutFail_ X2apCuFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutFail_ X2apLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~214748 3647
-
-
InterFreqNoMe asGapOutFail_ X2apRoTo
count
The cumulated number of timeouts that occur during the inter X2 HO execution procedure when the frequency information is different between
This counter is collected when when timeouts occur during the inter X2 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used,
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
635
Chapter 2 Counter Description Name
InterFreqNoMe asGapOutFail_ X2apSigFail
Unit
count
Description
Trigger
the source eNB (cell) and target eNB (cell) and the measurement gap is not used, the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
the source eNB transmits a RCC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE, then an UE context release command message is transmitted to the source eNB but the source eNB does not receive the message.
The cumulated number of releases due to receiving X2AP signaling during the inter X2 HO execution procedure when the frequency information is different between the source eNB (cell) and target
This counter is cumulated when a call is released due to receiving X2AP signaling during the inter X2 HO execution procedure when the frequency information is different between the source eNB (cell) and target eNB (cell) and the measurement gap is not used.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~214748 3647
-
-
636
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
eNB (cell) and the measurement gap is not used. InterFreqOutWi thOutGapCnt
count
The cumulated collection count of Outgoing Interfrequency Handover without Measurement Gap
This counter is cumulated by 1 when InterFreqOutWithGap is collected
-
CC
event
int
0~214748 3647
-
-
InterFreqOutWi thOutGapTarg etEarfcnDL
Target Earfcn Dl
The TargetEarfcnDl which collection is requested
This counter is calculated when measurement period comes.
-
OW
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
637
Chapter 2 Counter Description
Collection Time Figure 427. Collection Time for Outgoing Inter-Frequency HO without Measurement Gap (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
② InterFreqNoMeasGapOutPrepSucc
HO Decision
Resource Setup Success
RRC Connection Reconfiguration ③ InterFreqNoMeasGapOutSucc
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
RRC Connection Reconfiguration Complete
638
Chapter 2 Counter Description
Figure 428. Collection Time for Outgoing Inter-Frequency HO without Measurement Gap (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① InterFreqNoMeasGapOutAtt
Handover Request Acknowledge
② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge ③ InterFreqNoMeasGapOutSucc
UE Context Release
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
639
Chapter 2 Counter Description
Figure 429. Collection Time for Outgoing Inter-Frequency HO without Measurement Gap (S1) UE
EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqNoMeasGapOutAtt Handover Request Handover Request Acknowledge ② InterFreqNoMeasGapOutPrepSucc
Handover Command
Rrc Connection Reconfiguration eNB Status Transfer Rrc Connection Reconfiguration Complete
MME Status Transfer Handover Notify
Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete ③ InterFreqNoMeasGapOutSucc Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
640
Chapter 2 Counter Description
Collection Time (Failure) Figure 430. Collection Time for InterFreqNoMeasGapOutPrepFail_CpCcFail (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision Resource Setup Success
Case 1.
ECMB reset
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
641
Chapter 2 Counter Description
Figure 431. Collection Time for InterFreqNoMeasGapOutPrepFail_CpCcFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request
Case 1.
ECMB reset
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
642
Chapter 2 Counter Description
Figure 432. Collection Time for InterFreqNoMeasGapOutPrepFail_CpCcFail (S1) UE
Source eNB (earfcn A)
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledge
Case 1.
ECMB reset
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqNoMeasGapOutPrepFail_CpCcFail
Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
643
Chapter 2 Counter Description
Figure 433. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apCuFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
② Failure - InterFreqNoMeasGapOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
644
Chapter 2 Counter Description Figure 434. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apCuFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request S1AP UE CONTEXT RELEASE COMMAND
② Failure - InterFreqNoMeasGapOutPrepFail_S1apCuFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
645
Chapter 2 Counter Description
Figure 435. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apCuFail (S1) Source eNB (earfcn A)
UE
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqNoMeasGapOutAtt Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND ② Failure - InterFreqNoMeasGapOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
646
Chapter 2 Counter Description
Figure 436. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision Resource Setup Success S1AP Link is Out of Service Status
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqNoMeasGapOutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterFreqNoMeasGapOutPrepFail_S1apLinkFail
647
Chapter 2 Counter Description
Figure 437. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apLinkFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request S1AP Link is Out of Service Status
Case 1.
Case 2.
② Failure - InterFreqNoMeasGapOutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterFreqNoMeasGapOutPrepFail_S1apLinkFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
648
Chapter 2 Counter Description
Figure 438. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apLinkFail (S1) UE
Source eNB (earfcn A)
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqNoMeasGapOutAtt Handover Request Handover Request Acknowledge S1AP Link is Out of Service Status Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqNoMeasGapOutPrepFail_S1apLinkFail
SCTB reset
② Failure - InterFreqNoMeasGapOutPrepFail_S1apLinkFail
649
Chapter 2 Counter Description Figure 439. Collection Time for InterFreqMeasGapOutPrepFail_S1apRpTo UE
EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqNoMeasGapOutAtt
Handover Request Handover Request Acknowledge
Timeout
Handover Command X ② Failure - InterFreqNoMeasGapOutPrepFail_S1apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
650
Chapter 2 Counter Description
Figure 440. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apSigFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
Case 1.
② Failure - InterFreqNoMeasGapOutPrepFail_S1apSigFail
S1AP RESET Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqNoMeasGapOutPrepFail_S1apSigFail
651
Chapter 2 Counter Description
Figure 441. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apSigFail (X2) UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request S1AP UE CONTEXT RELEASE COMMAND
Case 1.
② Failure - InterFreqNoMeasGapOutPrepFail_S1apSigFail S1AP RESET
Case 2.
② Failure - InterFreqNoMeasGapOutPrepFail_S1apSigFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
652
Chapter 2 Counter Description Figure 442. Collection Time for InterFreqNoMeasGapOutPrepFail_S1apSigFail (S1) UE
Source eNB (earfcn A)
EPC
Target eNB (earfcn B)
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required ① InterFreqNoMeasGapOutAtt Handover Request Handover Request Acknowledge
S1AP UE CONTEXT RELEASE COMMAND Case 1.
② Failure - InterFreqNoMeasGapOutPrepFail_S1apSigFail
S1AP RESET Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - InterFreqNoMeasGapOutPrepFail_S1apSigFail
653
Chapter 2 Counter Description Figure 443. Collection Time for InterFreqNoMeasGapOutPrepFail_X2apCuFail Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request Handover Preparation Failure
② Failure - InterFreqNoMeasGapOutPrepFail_X2apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
654
Chapter 2 Counter Description Figure 444. Collection Time for InterFreqNoMeasGapOutPrepFail_X2apRpTo Source eNB (earfcn A)
UE
Target eNB (earfcn B)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt Time out
Handover Request Handover Request Acknowledge X
② Fail - InterFreqNoMeasGapOutPrepFail_X2apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
655
Chapter 2 Counter Description Figure 445. Collection Time for InterFreqNoMeasGapOutFail_CpCcTo (Intra Enb) eNB Source Cell PDCP/RLC
UE
Source Cell ECCB (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision
Resource Setup ② InterFreqNoMeasGapOutPrepSucc
Success
RRC Connection Reconfiguration Re-establish control Success X
Timer Internal Reestablish Control ③ Failure - InterFreqNoMeasGapOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
656
Chapter 2 Counter Description
Figure 446. Collection Time for InterFreqNoMeasGapOutFail_CpCcTo (X2) UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision
① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer Forward Path Setup Case 1.
Success Message X
Reestablish Control Case 2.
Success Message X
③ Failure - InterFreqNoMeasGapOutFail_CpCcTo
③ Failure - InterFreqNoMeasGapOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
657
Chapter 2 Counter Description
Figure 447. Collection Time for InterFreqNoMeasGapOutFail_CpCcTo (S1) UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① InterFreqNoMeasGapOutAtt
Handover Request Handover Request Acknowledge Handover Command
② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
Forward Path Setup Case 1.
Success Message X
③ Failure - InterFreqNoMeasGapOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - InterFreqNoMeasGapOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
658
Chapter 2 Counter Description
Figure 448. Collection Time for InterFreqNoMeasGapOutFail_CpCcFail (Intra eNB) eNB UE
Source Cell (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision
② InterFreqNoMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration
Case 1.
ECMB reset
Case 2.
Cell disabled
Case 3.
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
659
Chapter 2 Counter Description
Figure 449. Collection Time for InterFreqNoMeasGapOutFail_CpCcFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request
② InterFreqNoMeasGapOutPrepSucc
Handover Request Acknowledge
RRC Connection Reconfiguration
SN Status Transfer
Case 1.
ECMB reset
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
660
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
661
Chapter 2 Counter Description Figure 450. Collection Time for InterFreqNoMeasGapOutFail_CpCcFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledge
② InterFreqNoMeasGapOutPrepSucc
Handover Command
RRC Connection Reconfiguration ② Failure - InterFreqNoMeasGapOutFail_CpCcFail
Case 1.
ECMB reset
Case 2.
Cell disabled
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
② Failure - InterFreqNoMeasGapOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
662
Chapter 2 Counter Description Figure 451. Collection Time for InterFreqNoMeasGapOutFail_UpGtpFail (X2) Source eNB (earfcn A)
UE
GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
663
Chapter 2 Counter Description
Figure 452. Collection Time for InterFreqNoMeasGapOutFail_UpGtpFail (S1) Source eNB (earfcn A)
UE
GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request
② InterFreqNoMeasGapOutPrepSucc
Handover Request Acknowledge Handover Command
RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpGtpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
664
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
665
Chapter 2 Counter Description Figure 453. Collection Time for InterFreqNoMeasGapOutFail_UpMacFail eNB Source Cell PDCP/RLC
UE
Source Cell ECCB (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision
② InterFreqNoMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Success
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - InterFreqNoMeasGapOutFail_UpMacFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
666
Chapter 2 Counter Description Figure 454. Collection Time for InterFreqNoMeasGapOutFail_UpPdcpFail (X2) Source eNB (earfcn A)
UE
PDCP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpPdcpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
667
Chapter 2 Counter Description
Figure 455. Collection Time for InterFreqNoMeasGapOutFail_UpPdcpFail (S1) Source eNB (earfcn A)
UE
PDCP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledge
② InterFreqNoMeasGapOutPrepSucc
Handover Command
RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpPdcpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
668
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
669
Chapter 2 Counter Description Figure 456. Collection Time for InterFreqNoMeasGapOutFail_UpRlcFail (Intra eNB) eNB Source Cell RLC
UE
Source Cell ECCB (earfcn A)
Target Cell (earfcn B)
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision
② InterFreqNoMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Case 1.
Case 2.
Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpRlcFail
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - InterFreqNoMeasGapOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
670
Chapter 2 Counter Description Figure 457. Collection Time for InterFreqNoMeasGapOutFail_UpRlcFail (X2) Source eNB (earfcn A)
UE
RLC
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpRlcFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
671
Chapter 2 Counter Description
Figure 458. Collection Time for InterFreqNoMeasGapOutFail_UpRlcFail (S1) Source eNB (earfcn A)
UE
RLC
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledge
② InterFreqNoMeasGapOutPrepSucc
Handover Command
RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - InterFreqNoMeasGapOutFail_UpRlcFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
672
Chapter 2 Counter Description
Figure 459. Collection Time for InterFreqNoMeasGapOutFail_S1apCuFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
HO Decision
② InterFreqNoMeasGapOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration S1AP UE CONTEXT RELEASE COMMAND ③ Failure - InterFreqNoMeasGapOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
673
Chapter 2 Counter Description
Figure 460. Collection Time for InterFreqNoMeasGapOutFail_S1apCuFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Request
② InterFreqNoMeasGapOutPrepSucc
Handover Request Acknowledge
RRC Connection Reconfiguration
SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - InterFreqNoMeasGapOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
674
Chapter 2 Counter Description
Figure 461. Collection Time for InterFreqNoMeasGapOutFail_S1apCuFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledge
② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer MME Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - InterFreqNoMeasGapOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
675
Chapter 2 Counter Description
Figure 462. Collection Time for InterFreqNoMeasGapOutFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell (earfcn A)
EPC Target Cell (earfcn B)
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① InterFreqNoMeasGapOutAtt
② InterFreqNoMeasGapOutPrepSucc
HO Decision Resource Setup Success
RRC Connection Reconfiguration
S1AP Link is Out of Service Status Case 1.
Case 2.
② Failure - InterFreqNoMeasGapOutFail_S1apLinkFail
SCTB reset
② Failure - InterFreqNoMeasGapOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
676
Chapter 2 Counter Description
Figure 463. Collection Time for InterFreqNoMeasGapOutFail_S1apLinkFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Case 1.
Case 2.
S1AP Link is Out of Service Status ③ Failure - InterFreqNoMeasGapOutFail_S1apLinkFail
SCTB reset
③ Failure - InterFreqNoMeasGapOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
677
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
678
Chapter 2 Counter Description Figure 464. Collection Time for InterFreqNoMeasGapOutFail_S1apLinkFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledge
② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
Case 1.
Case 2.
Handover Command eNB Status Transfer
MME Status Transfer
S1AP Link is Out of Service Status ③ Failure - InterFreqNoMeasGapOutFail_S1apLinkFail
SCTB reset
③ Failure - InterFreqNoMeasGapOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
679
Chapter 2 Counter Description Figure 465. Collection Time for InterFreqNoMeasGapOutFail_S1apRoTo UE
Source eNB (earfcn A) RLC/PDCP/GTP
Target eNB (earfcn B)
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① InterFreqNoMeasGapOutAtt
Handover Request Handover Request Acknowledge Handover Command
② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer Timer RelocOverall
MME Status Transfer
Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command ③ Failure - InterFreqNoMeasGapOutFail_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
680
Chapter 2 Counter Description
Figure 466. Collection Time for InterFreqNoMeasGapOutFail_S1apSigFail (X2) Target eNB (earfcn B)
Source eNB (earfcn A)
UE
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - InterFreqNoMeasGapOutFail_S1apSigFail
Case 2.
S1AP RESET ③ Failure - InterFreqNoMeasGapOutFail_S1apSigFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
681
Chapter 2 Counter Description
Figure 467. Collection Time for InterFreqNoMeasGapOutFail_S1apSigFail (S1) EPC
Target eNB (earfcn B)
Source eNB (earfcn A)
UE
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt
Handover Required Handover Request Handover Request Acknowledg
② InterFreqNoMeasGapOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer
MME Status Transfer
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - InterFreqNoMeasGapOutFail_S1apSigFail
Case 2.
S1AP RESET ③ Failure - InterFreqNoMeasGapOutFail_S1apSigFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
682
Chapter 2 Counter Description
Figure 468. Collection Time for InterFreqNoMeasGapOutFail_X2apRoTo UE
Target eNB (earfcn B)
Source eNB (earfcn A)
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① InterFreqNoMeasGapOutAtt ② InterFreqNoMeasGapOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer HO Execution Timerout X2relocOverall
RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release X ③ Failure - InterFreqNoMeasGapOutFail_X2apRoTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
683
Chapter 2 Counter Description
Outgoing Handover with DRX This section provides statistic on the outgoing Handover with DRX. The handover statistics are collected when the DRX is set for the UE. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DrxOutAtt
count
The following counts are collected when DRX is configured in the UE.
This counter is collected when when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
Intra eNB: The cumulated number when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Intra eNB: This counter is cumulated when the Intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: The cumulated number when inter X2 HO is judged in the HO decision based on the source cell when a measurement report message is received from the UE.
Inter S1: The cumulated number when inter S1 HO is judged in the HO decision based on the source cell after a Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Inter X2: This counter is cumulated when the Inter X2 HO is judged in the HO decision based on the source cell when a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the Inter S1 HO is judged in the HO decision based on the 684
Chapter 2 Counter Description Name
Unit
Description measurement report message is received from the UE.
DrxOutPr epSucc
count
Trigger
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474 83647
-
-
source cell after a measurement report message is received from the UE.
The following counts are collected when DRX is configured in the UE.
This counter is collected when DRX is configured in the UE.
Intra eNB: The cumulated number when the transmission of a RRC connection reconfiguration message to the UE is completed after handover preparation to the target cell between the inner blocks is completed when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Intra eNB: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after handover preparation to the target cell between the inner blocks is completed when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: The cumulated number when the transmission of a RRC connection reconfiguration message to the UE is completed after a handover request is transmitted to the target eNB and a handover request acknowledge message is received from the target eNB when inter
Inter X2: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a handover request is transmitted to the target eNB and a handover request acknowledge message is received from the target eNB when inter X2 HO is
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
685
Chapter 2 Counter Description Name
Unit
Description X2 HO is judged in the HO decision after a measurement report message is received from the UE.
Inter S1: The cumulated number when the transmission of a RRC connection reconfiguration message to the UE is completed after a S1 handover required message is transmitted to MME and a S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after a measurement report message is received from the UE.
DrxOutSu cc
count
Trigger
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474 83647
-
-
judged in the HO decision after a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a S1 handover required message is transmitted to MME and a S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after a measurement report message is received from the UE.
The following counts are collected when DRX is configured in the UE.
This counter is collected when DRX is configured in the UE.
Intra eNB: The cumulated number when the target cell normally receives a RRC connection reconfiguration complete message from the UE after intra HO is executed.
Intra eNB: This counter is cumulated when the target cell normally receives a RRC connection reconfiguration complete message from the UE after intra HO is executed.
Inter X2: The cumulated number when the source eNB normally receives an
Inter X2: This counter is cumulated when the source eNB normally receives an
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
686
Chapter 2 Counter Description Name
DrxOutPr epFail_C pCcFail
Unit
count
Description
Trigger
UE context release command message after inter X2 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
UE context release command message after inter X2 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
Inter S1: The cumulated number when the source eNB normally receives an UE context release command message after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
Inter S1: This counter is cumulated when the source eNB normally receives an UE context release command message after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
The cumulated number when execution fails due to a reset notification (eNB failure or
This counter is cumulated as follows when DRX is configured in the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474 83647
-
-
687
Chapter 2 Counter Description Name
DrxOutPr
Unit
count
Description
Trigger
block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is configured in the UE.
This counter is cumulated when a call is release due to ECMB reset during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO preparation procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO preparation procedure
The cumulated number when
This counter is cumulated
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474
-
688
Chapter 2 Counter Description Name
Unit
epFail_S 1apCuFai l
Description
Trigger
execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is configured in the UE.
when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is configured in the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
DrxOutPr epFail_S 1apLinkF ail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
DrxOutPr epFail_S 1apRpTo
count
The cumulated number when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1 handover required message to MME during the inter S1 HO preparation procedure when DRX is configured in the UE.
This counter is cumulated when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1 handover required message to MME during the inter S1 HO preparation procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
DrxOutPr epFail_S 1apSigFa il
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is configured in the UE.
This counter is cumulated as follows when DRX is configured in the UE. This counter is cumulated when a call is release due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
689
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when a call is release due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure DrxOutPr epFail_X 2apCuFai l
count
The cumulated number when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is configured in the UE.
This counter is cumulated when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
DrxOutPr epFail_X 2apLinkF ail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
DrxOutPr epFail_X 2apRpTo
count
The cumulated number when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is configured in the UE.
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
690
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DrxOutPr epFail_X 2apSigFa il
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_CpCcT o
count
The cumulated number when a call is released due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2, or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2, or inter S1 HO execution procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_CpCcF ail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated as follows when DRX is configured in the UE. This counter is cumulated when the eNB releases a call due to ECMB reset during Intra eNB, Inter X2 (S1) HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO execution
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
691
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO execution procedure DrxOutFa il_UpGtp Fail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_UpMac Fail
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the intra eNB, inter X2 or inter S1 HO execution
This counter is cumulated as follows when DRX is configured in the UE. This counter is cumulated when execution fails since Fail is received as a response message from
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
692
Chapter 2 Counter Description Name
Unit
Description
Trigger
procedure when DRX is configured in the UE.
the MAC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DrxOutFa il_UpPdc pFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_UpRlcF ail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated as follows when DRX is configured in the UE. This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
693
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures. DrxOutFa il_RrcSig Fail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_S1apC uFail
count
The cumulated number of releases due to a S1AP specification cause that occurs during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated when a call is released due to a S1AP specification cause that occurs during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_S1apLi nkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated as follows when DRX is configured in the UE. This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Intra eNB, Inter X2 (Inter S1) HO execution Procedure This counter is cumulated when a call is release due to SCTB reset during Intra eNB, Inter X2 (Inter S1) HO
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
694
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DrxOutFa il_S1apR oTo
count
The cumulated number when timeout occurs during the inter S1 HO execution procedure while DRX is configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
This counter is cumulated when timeout occurs during the inter S1 HO execution procedure while DRX is configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_S1apSi gFail
count
The cumulated number when execution fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is configured in the UE.
This counter is cumulated as follows when DRX is configured in the UE. This counter is cumulated when a call is release due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is release due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa
count
This counter is not collected
None
Y
CC
event
int
0~21474
-
-
execution procedure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
695
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
in the system
il_X2apC uFail
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
DrxOutFa il_X2apLi nkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_X2apR oTo
count
The cumulated number when timeout occurs during the Inter X2 HO execution procedure while DRX is configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release message to the source eNB but the message is not received.
This counter is cumulated when timeout occurs during the Inter X2 HO execution procedure while DRX is configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release message to the source eNB but the message is not received.
Y
CC
event
int
0~21474 83647
-
-
DrxOutFa il_X2apSi gFail
count
This counter is cumulated when call is released due to receiving X2AP signaling during the outgoing handover (with DRX) execution.
This counter is cumulated when a release occurs since X2AP signaling is received during the inter X2 HO execution procedure when DRX is configured in the UE.
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
696
Chapter 2 Counter Description
Collection Time Figure 469. Collection Time for Outgoing Handover with DRX (Intra eNB) eNB UE
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
② DrxOutPrepSucc
HO Decision
Resource Setup Success
RRC Connection Reconfiguration RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
697
Chapter 2 Counter Description
Figure 470. Collection Time for Outgoing Handover with DRX (X2) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request
① DrxOutAtt
Handover Request Acknowledge
② DrxOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge ③ DrxOutSucc
UE Context Release
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
698
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
699
Chapter 2 Counter Description Figure 471. Collection Time for Outgoing Handover with DRX (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② DrxOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify
Tracking Area Update Procedure (NAS) UE Context Release Command ③ DrxOutSucc
UE Context Release Complete
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
700
Chapter 2 Counter Description
Figure 472. Collection Time for DrxOutPrepFail_CpCcFail (Intra eNB) eNB UE
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision Resource Setup Success
Case 1.
ECMB reset
② Failure - DrxOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - DrxOutPrepFail_CpCcFail
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - DrxOutPrepFail_CpCcFail
701
Chapter 2 Counter Description
Figure 473. Collection Time for DrxOutPrepFail_CpCcFail (X2) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Request
Case 1.
ECMB reset
② Failure - DrxOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - DrxOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - DrxOutPrepFail_CpCcFail
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
702
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
703
Chapter 2 Counter Description Figure 474. Collection Time for DrxOutPrepFail_CpCcFail (S1) UE
Source eNB
EPC
Target eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
ECMB reset
② Failure - DrxOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - DrxOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
Case 1.
② Failure - DrxOutPrepFail_CpCcFail
Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
704
Chapter 2 Counter Description
Figure 475. Collection Time for DrxOutPrepFail_S1apCuFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision Resource Setup Success S1AP UE CONTEXT RELEASE COMMAND
② Failure - DrxOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
705
Chapter 2 Counter Description
Figure 476. Collection Time for DrxOutPrepFail_S1apCuFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Request
S1AP UE CONTEXT RELEASE COMMAND ② Failure - DrxOutPrepFail_S1apCuFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
706
Chapter 2 Counter Description
Figure 477. Collection Time for DrxOutPrepFail_S1apCuFail (S1) UE
Source eNB
EPC
Target eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
S1AP UE CONTEXT RELEASE COMMAND ② Failure - DrxOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
707
Chapter 2 Counter Description
Figure 478. Collection Time for DrxOutPrepFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision Resource Setup Success S1AP Link is Out of Service Status
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - DrxOutPrepFail_S1apLinkFail
SCTB reset
② Failure - DrxOutPrepFail_S1apLinkFail
708
Chapter 2 Counter Description
Figure 479. Collection Time for DrxOutPrepFail_S1apLinkFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Case 1.
Case 2.
Handover Request
S1AP Link is Out of Service Status ② Failure - DrxOutPrepFail_S1apLinkFail
SCTB reset
② Failure - DrxOutPrepFail_S1apLinkFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
709
Chapter 2 Counter Description
Figure 480. Collection Time for DrxOutPrepFail_S1apLinkFail (S1) UE
Source eNB
EPC
Target eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
S1AP Link is Out of Service Status ② Failure - DrxOutPrepFail_S1apLinkFail
SCTB reset
② Failure - DrxOutPrepFail_S1apLinkFail
710
Chapter 2 Counter Description
Figure 481. Collection Time for DrxOutPrepFail_S1apRpTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledge
Timeout
X
Handover Command
② Failure - DrxOutPrepFail_S1apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
711
Chapter 2 Counter Description
Figure 482. Collection Time for DrxOutPrepFail_S1apSigFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision Resource Setup Success
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - DrxOutPrepFail_S1apSigFail
Case 2.
③ Failure - DrxOutPrepFail_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
S1AP RESET
712
Chapter 2 Counter Description
Figure 483. Collection Time for DrxOutPrepFail_S1apSigFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Request
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - DrxOutPrepFail_S1apSigFail
Case 2.
③ Failure - DrxOutPrepFail_S1apSigFail
S1AP RESET
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
713
Chapter 2 Counter Description
Figure 484. Collection Time for DrxOutPrepFail_S1apSigFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ② Failure - DrxOutPrepFail_S1apSigFail
Case 2.
② Failure - DrxOutPrepFail_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
S1AP RESET
714
Chapter 2 Counter Description
Figure 485. Collection Time for DrxOutPrepFail_X2apCuFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Request Handover Preparation Failure
② Failure - DrxOutPrepFail_X2apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
715
Chapter 2 Counter Description
Figure 486. Collection Time for DrxOutPrepFail_X2apRpTo UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Request
Time out X
Handover Request Acknowledge
② Fail - DrxOutPrepFail_X2apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
716
Chapter 2 Counter Description
Figure 487. Collection Time for DrxOutFail_CpCcTo (Intra eNB) eNB Source Cell PDCP/RLC
UE
Source Cell ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision
Resource Setup ② DrxOutPrepSucc
Success
RRC Connection Reconfiguration Re-establish control Success X RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Timer Internal Reestablish Control ③ Failure - DrxOutFail_CpCcTo
717
Chapter 2 Counter Description
Figure 488. Collection Time for DrxOutFail_CpCcTo (X2) UE
Source eNB
Target eNB
RLC/PDCP/GTP
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① DrxOutAtt ② DrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Forward Path Setup Case 1.
Success Message X
③ Failure - DrxOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - DrxOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
718
Chapter 2 Counter Description
Figure 489. Collection Time for DrxOutFail_CpCcTo (S1) UE
Source eNB
EPC
Target eNB
RLC/PDCP/GTP
ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② DrxOutPrepSucc RRC Connection Reconfiguration
Forward Path Setup Case 1.
Success Message X
③ Failure - DrxOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - DrxOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
719
Chapter 2 Counter Description
Figure 490. Collection Time for DrxOutFail_CpCcFail (Intra eNB) eNB UE
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision
② DrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - DrxOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - DrxOutFail_CpCcFail
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - DrxOutFail_CpCcFail
720
Chapter 2 Counter Description
Figure 491. Collection Time for DrxOutFail_CpCcFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Request
② DrxOutPrepSucc
Handover Request Acknowledge
RRC Connection Reconfiguration
SN Status Transfer
Case 1.
ECMB reset
② Failure - DrxOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - DrxOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - DrxOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
721
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
722
Chapter 2 Counter Description Figure 492. Collection Time for DrxOutFail_CpCcFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② DrxOutPrepSucc
Handover Command
RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - DrxOutFail_CpCcFail
Case 2.
Cell disabled ② Failure - DrxOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - DrxOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
723
Chapter 2 Counter Description
Figure 493. Collection Time for DrxOutFail_UpGtpFail (X2) Source eNB
UE
GTP
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① DrxOutAtt ② DrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - DrxOutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
724
Chapter 2 Counter Description
Figure 494. Collection Time for DrxOutFail_UpGtpFail (S1) Source eNB
UE
GTP
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② DrxOutPrepSucc
Handover Command
RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - DrxOutFail_UpGtpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
725
Chapter 2 Counter Description
Figure 495. Collection Time for DrxOutFail_UpMacFail eNB Source Cell PDCP/RLC
UE
Source Cell ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision
② DrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Success A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - DrxOutFail_UpMacFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
726
Chapter 2 Counter Description
Figure 496. Collection Time for DrxOutFail_UpPdcpFail (X2) Source eNB
UE
PDCP
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① DrxOutAtt ② DrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - DrxOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
727
Chapter 2 Counter Description
Figure 497. Collection Time for DrxOutFail_UpPdcpFail (S1) Source eNB
UE
PDCP
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② DrxOutPrepSucc RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - DrxOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
728
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
729
Chapter 2 Counter Description Figure 498. Collection Time for DrxOutFail_UpRlcFail (Intra eNB) eNB Source Cell RLC
UE
Source Cell ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision
② DrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration
Case 1.
Re-establish control Fail Message
Case 2.
③ Failure - DrxOutFail_UpRlcFail
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - DrxOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
730
Chapter 2 Counter Description
Figure 499. Collection Time for DrxOutFail_UpRlcFail (X2) Source eNB
UE
RLC
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt ② DrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - DrxOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
731
Chapter 2 Counter Description
Figure 500. Collection Time for DrxOutFail_UpRlcFail (S1) Source eNB
UE
RLC
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② DrxOutPrepSucc RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - DrxOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
732
Chapter 2 Counter Description
Figure 501. Collection Time for DrxOutFail_S1apCuFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
HO Decision
② DrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration S1AP UE CONTEXT RELEASE COMMAND ③ Failure - DrxOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
733
Chapter 2 Counter Description
Figure 502. Collection Time for DrxOutFail_S1apCuFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt ② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - DrxOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
734
Chapter 2 Counter Description
Figure 503. Collection Time for DrxOutFail_S1apCuFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer MME Status Transfer
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - DrxOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
735
Chapter 2 Counter Description
Figure 504. Collection Time for DrxOutFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① DrxOutAtt
② DrxOutPrepSucc
HO Decision Resource Setup Success
RRC Connection Reconfiguration S1AP Link is Out of Service Status Case 1.
Case 2.
② Failure - DrxOutFail_S1apLinkFail
SCTB reset
② Failure - DrxOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
736
Chapter 2 Counter Description
Figure 505. Collection Time for DrxOutFail_S1apLinkFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt ② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer
③ Failure - DrxOutFail_S1apLinkFail
Case 1.
SCTB reset
Case 2.
S1AP Link is Out of Service Status
③ Failure - DrxOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
737
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
738
Chapter 2 Counter Description Figure 506. Collection Time for DrxOutFail_S1apLinkFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledge
② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer
③ Failure - DrxOutFail_S1apLinkFail
Case 1.
SCTB reset
Case 2.
MME Status Transfer
S1AP Link is Out of Service Status
③ Failure - DrxOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
739
Chapter 2 Counter Description Figure 507. Collection Time for DrxOutFail_S1apRoTo UE
Source eNB RLC/PDCP/GTP
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer Timer RelocOverall
MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command ③ Failure - DrxOutFail_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
740
Chapter 2 Counter Description
Figure 508. Collection Time for DrxOutFail_S1apSigFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt ② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - DrxOutFail_S1apSigFail
Case 2.
③ Failure - DrxOutFail_S1apSigFail
S1AP RESET
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
741
Chapter 2 Counter Description
Figure 509. Collection Time for DrxOutFail_S1apSigFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① DrxOutAtt
Handover Request Handover Request Acknowledg ② DrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer MME Status Transfer
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - DrxOutFail_S1apSigFail
Case 2.
③ Failure - DrxOutFail_S1apSigFail
S1AP RESET
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
742
Chapter 2 Counter Description Figure 510. Collection Time for DrxOutFail_X2apRoTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① DrxOutAtt ② DrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Timerout X2relocOverall
HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release X ③ Failure - DrxOutFail_X2apRoTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
743
Chapter 2 Counter Description
Outgoing Handover without DRX This section provides statistics on the handover when DRX is not set on the UE. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tAtt
count
The cumulated number of outgoing handover (without DRX) attempt count
This counter is collected when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
Intra eNB: This counter is cumulated when the Intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the Inter X2 HO is judged in the HO decision based on the source cell when a measurement report message is received from the UE.
Inter S1: This counter is cumulated when the Inter S1 HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
744
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tPrepSuc c
count
The cumulated number of outgoing handover (without DRX) preparation success count
This counter is collected when when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
Intra eNB: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after handover preparation to the target cell between the inner blocks is completed when intra HO is judged in the HO decision based on the source cell after a measurement report message is received from the UE.
Inter X2: This counter is cumulated when the transmission of a RRC connection reconfiguration message to the UE is completed after a handover request is transmitted to the target eNB and a handover request acknowledge message is received from the target eNB when inter X2 HO is judged in the HO decision after a measurement report message is received from the UE.
Inter S1: This counter is cumulated when transmission of a RRC connection reconfiguration message to the
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
745
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
UE is completed after a S1 handover required message is transmitted to MME and a S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after a measurement report message is received from the UE. NoDrxOu tSucc
count
The cumulated number of outgoing handover (without DRX) execution success count
This counter is collected when DRX is not configured in the UE.
Intra eNB: This counter is cumulated when the target cell normally receives a RRC connection reconfiguration complete message from the UE after intra HO is executed.
Inter X2: This counter is cumulated when the source eNB normally receives an UE context release command message after inter X2 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB.
Inter S1: This counter is cumulated when the source eNB normally receives an UE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
746
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21 4748 3647
-
-
context release command message after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE, the target eNB receives a RRC connection reconfiguration complete message from the UE, and an UE context release command message is transmitted to the source eNB. NoDrxOu tPrepFail _CpCcFa il
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is not configured in the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated as follows when DRX is not configured in the UE. This counter is cumulated when a call is released due to ECMB reset during Intra eNB, Inter X2 (Inter S1) HO preparation This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during
747
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
the intra eNB and inter X2 (inter S1) HO preparation procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation duringIntra eNB, Inter X2 (Inter S1) HO preparation procedure NoDrxOu tPrepFail _S1apCu Fail
count
The cumulated number when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is not configured in the UE.
This counter is cumulated when execution fails since a S1AP specification cause occurs during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tPrepFail _S1apLin kFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tPrepFail _S1apRp To
count
The cumulated number when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1 handover required message to MME during the inter S1 HO preparation procedure when DRX is not configured in the UE.
This counter is cumulated when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1 handover required message to MME during the inter S1 HO preparation procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu
count
The cumulated number
This counter is cumulated as
Y
CC
event
int
0~21
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
748
Chapter 2 Counter Description Name
Unit
tPrepFail _S1apSig Fail
Description
Trigger
when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra eNB, inter X2 or inter S1 HO preparation procedure when DRX is not configured in the UE.
follows when DRX is not configured in the UE. This counter is cumulated when a call is release due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure This counter is cumulated when a call is release due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO preparation procedure
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 4748 3647
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tPrepFail _X2apCu Fail
count
The cumulated number when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is not configured in the UE.
This counter is cumulated when preparation fails since the serving eNB receives a handover preparation failure message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tPrepFail _X2apLin kFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tPrepFail _X2apRp To
count
The cumulated number when preparation fails due to a timeout that has occurred since the serving eNB has not received a
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
749
Chapter 2 Counter Description Name
Unit
Description
Trigger
handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is not configured in the UE.
message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure when DRX is not configured in the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tPrepFail _X2apSig Fail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_Cp CcTo
count
The cumulated number when a call is released due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2, or inter S1 HO execution procedure when DRX is not configured in the UE.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after a call control message is transmitted to the inner block during the intra eNB, inter X2, or inter S1 HO execution procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_Cp CcFail
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured
This counter is cumulated as follows when DRX is not configured in the UE. This counter is cumulated when a call is released due to ECMB reset during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
750
Chapter 2 Counter Description Name
Unit
Description
Trigger
in the UE.
This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tFail_Up GtpFail
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_Up
count
The cumulated number when execution fails since
This counter is cumulated as follows when DRX is not
Y
CC
event
int
0~21 4748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
751
Chapter 2 Counter Description Name
Unit
MacFail
Description
Trigger
Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
configured in the UE. This counter is cumulated when execution fails since Fail is received as a response message from the MAC during the intra eNB and inter X2 (inter S1) HO execution procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max 3647
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tFail_UpP dcpFail
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_Up RlcFail
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured
This counter is cumulated as follows when DRX is not configured in the UE. This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the intra eNB and inter X2 (inter S1) HO execution
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
752
Chapter 2 Counter Description Name
Unit
Description
Trigger
in the UE.
procedures. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the intra eNB and inter X2 (inter S1) HO execution procedures.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tFail_Rrc SigFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_S1a pCuFail
count
The cumulated number of releases due to a S1AP specification cause that occurs during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
This counter is cumulated when a call is released due to a S1AP specification cause that occurs during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_S1a pLinkFail
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
This counter is cumulated as follows when DRX is not configured in the UE. This counter is cumulated when the eNB releases the call because the status of the callrelated S1AP link has been changed to OOS (Out Of Service) during Intra eNB, Inter X2 (Inter S1) HO execution Procedure This counter is cumulated when a call is release due to SCTB
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
753
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
reset during Intra eNB, Inter X2 (Inter S1) HO execution procedure NoDrxOu tFail_S1a pRoTo
count
The cumulated number when timeout occurs during the inter S1 HO execution procedure while DRX is not configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
This counter is cumulated when timeout occurs during the inter S1 HO execution procedure while DRX is not configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_S1a pSigFail
count
The cumulated number when execution fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra eNB, inter X2 or inter S1 HO execution procedure when DRX is not configured in the UE.
This counter is cumulated as follows when DRX is not configured in the UE. This counter is cumulated when a call is release due to receiving S1AP UE CONTEXT RELEASE COMMAND from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure This counter is cumulated when a call is release due to receiving S1AP RESET from MME during Intra eNB, Inter X2 (Inter S1) HO execution procedure
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
754
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
NoDrxOu tFail_X2a pCuFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_X2a pLinkFail
count
This counter is not collected in the system
None
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_X2a pRoTo
count
The cumulated number when timeout occurs during the Inter X2 HO execution procedure while DRX is not configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release message to the source eNB but the message is not received.
This counter is cumulated when timeout occurs during the Inter X2 HO execution procedure while DRX is not configured in the UE since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC connection reconfiguration complete message from the UE and transmits an UE context release message to the source eNB but the message is not received.
Y
CC
event
int
0~21 4748 3647
-
-
NoDrxOu tFail_X2a pSigFail
count
The cumulated number when a call is released due to receiving X2AP signaling during the outgoing handover (without DRX) execution.
This counter is cumulated when a call is released due to receiving X2AP signaling during the outgoing handover (without DRX) execution.
Y
CC
event
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
755
Chapter 2 Counter Description
Collection Time (Success) Figure 511. Collection Time for Outgoing Handover without DRX (Intra eNB) eNB UE
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
② NoDrxOutPrepSucc
HO Decision Resource Setup Success
RRC Connection Reconfiguration ③ NoDrxOutSucc
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
RRC Connection Reconfiguration Complete
756
Chapter 2 Counter Description
Figure 512. Collection Time for Outgoing Handover without DRX (X2) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge
① NoDrxOutAtt ② NoDrxOutPrepSucc RRC Connection Reconfiguration
SN Status Transfer HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge ③ NoDrxOutSucc
UE Context Release
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
757
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
758
Chapter 2 Counter Description Figure 513. Collection Time for Outgoing Handover without DRX (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify
Tracking Area Update Procedure (NAS) UE Context Release Command ③ NoDrxOutSucc
UE Context Release Complete
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
759
Chapter 2 Counter Description
Collection Time (Failure) Figure 514. Collection Time for NoDrxOutPrepFail_CpCcFail (Intra eNB) eNB UE
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision Resource Setup
Case 1.
ECMB reset
② Failure - NoDrxOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - NoDrxOutPrepFail_CpCcFail
Case 3.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - NoDrxOutPrepFail_CpCcFail
760
Chapter 2 Counter Description
Figure 515. Collection Time for NoDrxOutPrepFail_CpCcFail (X2) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Request
Case 1.
ECMB reset
② Failure - NoDrxOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - NoDrxOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - NoDrxOutPrepFail_CpCcFail
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
761
Chapter 2 Counter Description Figure 516. Collection Time for NoDrxOutPrepFail_CpCcFail (S1) UE
Source eNB
EPC
Target eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
Case 1.
ECMB reset
② Failure - NoDrxOutPrepFail_CpCcFail
Case 2.
Cell disabled
② Failure - NoDrxOutPrepFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - NoDrxOutPrepFail_CpCcFail
Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
762
Chapter 2 Counter Description Figure 517. Collection Time for NoDrxOutPrepFail_S1apCuFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision Resource Setup Success
S1AP UE CONTEXT RELEASE COMMAND ② Failure - NoDrxOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
763
Chapter 2 Counter Description Figure 518. Collection Time for NoDrxOutPrepFail_S1apCuFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Request Handover Request Acknowledge S1AP UE CONTEXT RELEASE COMMAND
② Failure - NoDrxOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
764
Chapter 2 Counter Description
Figure 519. Collection Time for NoDrxOutPrepFail_S1apCuFail (S1) UE
Source eNB
EPC
Target eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
S1AP UE CONTEXT RELEASE COMMAND ② Failure - NoDrxOutPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
765
Chapter 2 Counter Description
Figure 520. Collection Time for NoDrxOutPrepFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision Resource Setup Success S1AP Link is Out of Service Status
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
② Failure - NoDrxOutPrepFail_S1apLinkFail
SCTB reset
② Failure - NoDrxOutPrepFail_S1apLinkFail
766
Chapter 2 Counter Description
Figure 521. Collection Time for NoDrxOutPrepFail_S1apLinkFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report
HO Decision ① NoDrxOutAtt
Case 1.
Case 2.
Handover Request
S1AP Link is Out of Service Status ② Failure - NoDrxOutPrepFail_S1apLinkFail
SCTB reset
② Failure - NoDrxOutPrepFail_S1apLinkFail Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
767
Chapter 2 Counter Description
Figure 522. Collection Time for NoDrxOutPrepFail_S1apLinkFail (S1) UE
Source eNB
EPC
Target eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
Case 1.
Case 2.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
S1AP Link is Out of Service Status ② Failure - NoDrxOutPrepFail_S1apLinkFail
SCTB reset
② Failure - NoDrxOutPrepFail_S1apLinkFail
768
Chapter 2 Counter Description
Figure 523. Collection Time for NoDrxOutPrepFail_S1apRpTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required Handover Request
① NoDrxOutAtt
Handover Request Acknowledge
Timeout
X
Handover Command
② Failure - NoDrxOutPrepFail_S1apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
769
Chapter 2 Counter Description
Figure 524. Collection Time for NoDrxOutPrepFail_S1apSigFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Inter eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision Resource Setup Success
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ② Failure - NoDrxOutPrepFail_S1apSigFail
Case 2.
S1AP RESET ② Failure - NoDrxOutPrepFail_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
770
Chapter 2 Counter Description
Figure 525. Collection Time for NoDrxOutPrepFail_S1apSigFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Request
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ② Failure - NoDrxOutPrepFail_S1apSigFail
Case 2.
② Failure - NoDrxOutPrepFail_S1apSigFail
S1AP RESET
Handover Request Acknowledge
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
771
Chapter 2 Counter Description
Figure 526. Collection Time for NoDrxOutPrepFail_S1apSigFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ② Failure - NoDrxOutPrepFail_S1apSigFail
Case 2.
② Failure - NoDrxOutPrepFail_S1apSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
S1AP RESET
772
Chapter 2 Counter Description
Figure 527. Collection Time for NoDrxOutPrepFail_X2apCuFail UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Request
Handover Preparation Failure ② Failure - NoDrxOutPrepFail_X2apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
773
Chapter 2 Counter Description
Figure 528. Collection Time for NoDrxOutPrepFail_X2apRpTo UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Request
Time out X
Handover Request Acknowledge
② Fail - NoDrxOutPrepFail_X2apRpTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
774
Chapter 2 Counter Description
Figure 529. Collection Time for NoDrxOutFail_CpCcTo (Intra eNB) eNB Source Cell PDCP/RLC
UE
Source Cell ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision
② NoDrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Success X RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Timer Internal Reestablish Control ③ Failure - NoDrxOutFail_CpCcTo
775
Chapter 2 Counter Description
Figure 530. Collection Time for NoDrxOutFail_CpCcTo (X2) UE
Source eNB
Target eNB
RLC/PDCP/GTP
ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer Forward Path Setup Case 1.
Success Message X
③ Failure - NoDrxOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - NoDrxOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
776
Chapter 2 Counter Description
Figure 531. Collection Time for NoDrxOutFail_CpCcTo (S1) UE
Source eNB
EPC
Target eNB
RLC/PDCP/GTP
ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration Forward Path Setup Case 1.
Success Message X
③ Failure - NoDrxOutFail_CpCcTo
Reestablish Control Case 2.
Success Message X
③ Failure - NoDrxOutFail_CpCcTo
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
777
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
778
Chapter 2 Counter Description Figure 532. Collection Time for NoDrxOutFail_CpCcFail (Intra eNB) eNB UE
Source Cell
Target Cell
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
② NoDrxOutPrepSucc
HO Decision Resource Setp Success
RRC Connection Reconfiguration
Case 1.
ECMB reset
② Failure - NoDrxOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - NoDrxOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - NoDrxOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
779
Chapter 2 Counter Description Figure 533. Collection Time for NoDrxOutFail_CpCcFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Case 1.
ECMB reset
② Failure - NoDrxOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - NoDrxOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - NoDrxOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
780
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
781
Chapter 2 Counter Description Figure 534. Collection Time for NoDrxOutFail_CpCcFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② NoDrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
Case 1.
ECMB reset
② Failure - NoDrxOutFail_CpCcFail
Case 2.
Cell disabled
② Failure - NoDrxOutFail_CpCcFail
Case 3.
Mismatch of UE information in the execution of audit between the ECCB and RLC/MAC.
② Failure - NoDrxOutFail_CpCcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
782
Chapter 2 Counter Description
Figure 535. Collection Time for NoDrxOutFail_UpGtpFail (X2) Source eNB
UE
GTP
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision
① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - NoDrxOutFail_UpGtpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
783
Chapter 2 Counter Description
Figure 536. Collection Time for NoDrxOutFail_UpGtpFail (S1) Source eNB
UE
GTP
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration Forward Path Setup Fail Message
③ Failure - NoDrxOutFail_UpGtpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
784
Chapter 2 Counter Description
Figure 537. Collection Time for NoDrxOutFail_UpMacFail eNB Source Cell PDCP/RLC
UE
Source Cell ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision
② NoDrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration Re-establish control Success A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - NoDrxOutFail_UpMacFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
785
Chapter 2 Counter Description
Figure 538. Collection Time for NoDrxOutFail_UpPdcpFail (X2) Source eNB
UE
PDCP
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - NoDrxOutFail_UpPdcpFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
786
Chapter 2 Counter Description
Figure 539. Collection Time for NoDrxOutFail_UpPdcpFail (S1) Source eNB
UE
PDCP
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration Handover Exec Fail Message
③ Failure - NoDrxOutFail_UpPdcpFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
787
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
788
Chapter 2 Counter Description Figure 540. Collection Time for NoDrxOutFail_UpRlcFail (Intra eNB) eNB Source Cell RLC
UE
Source Cell ECCB
Target Cell
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision
② NoDrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration
Case 1.
Re-establish control Fail Message
Case 2.
③ Failure - NoDrxOutFail_UpRlcFail
A mismatch of UE information occurred in the execution of audit between the ECCB and MAC. ③ Failure - NoDrxOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
789
Chapter 2 Counter Description
Figure 541. Collection Time for NoDrxOutFail_UpRlcFail (X2) Source eNB
UE
RLC
Target eNB ECCB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - NoDrxOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
790
Chapter 2 Counter Description
Figure 542. Collection Time for NoDrxOutFail_UpRlcFail (S1) Source eNB
UE
RLC
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration Re-establish Fail Message
③ Failure - NoDrxOutFail_UpRlcFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
791
Chapter 2 Counter Description
Figure 543. Collection Time for NoDrxOutFail_S1apCuFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt
HO Decision
② NoDrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration S1AP UE CONTEXT RELEASE COMMAND ③ Failure - NoDrxOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
792
Chapter 2 Counter Description
Figure 544. Collection Time for NoDrxOutFail_S1apCuFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer S1AP UE CONTEXT RELEASE COMMAND
③ Failure - NoDrxOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
793
Chapter 2 Counter Description
Figure 545. Collection Time for NoDrxOutFail_S1apCuFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② NoDrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer MME Status Transfer
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - NoDrxOutFail_S1apCuFail RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
794
Chapter 2 Counter Description
Figure 546. Collection Time for NoDrxOutFail_S1apLinkFail (Intra eNB) eNB UE
Source Cell
EPC Target Cell
MME
SGW
UE moves to Intra eNB Cell Measurement Report ① NoDrxOutAtt HO Decision
② NoDrxOutPrepSucc
Resource Setup Success
RRC Connection Reconfiguration S1AP Link is Out of Service Status Case 1.
Case 2.
② Failure - NoDrxOutFail_S1apLinkFail
SCTB reset
② Failure - NoDrxOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
795
Chapter 2 Counter Description
Figure 547. Collection Time for NoDrxOutFail_S1apLinkFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
S1AP Link is Out of Service Status ③ Failure - NoDrxOutFail_S1apLinkFail
Case 1.
SCTB reset
Case 2.
③ Failure - NoDrxOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
796
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
797
Chapter 2 Counter Description Figure 548. Collection Time for NoDrxOutFail_S1apLinkFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt
Handover Required Handover Request Handover Request Acknowledge
② NoDrxOutPrepSucc RRC Connection Reconfiguration
Handover Command
eNB Status Transfer MME Status Transfer
S1AP Link is Out of Service Status ③ Failure - NoDrxOutFail_S1apLinkFail
Case 1.
SCTB reset
Case 2.
③ Failure - NoDrxOutFail_S1apLinkFail
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
798
Chapter 2 Counter Description
Figure 549. Collection Time for NoDrxOutFail_S1apRoTo UE
Source eNB RLC/PDCP/GTP
EPC
Target eNB ECCB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledge Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer Timer RelocOverall
MME Status Transfer
RRC Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command ③ Failure - NoDrxOutFail_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
799
Chapter 2 Counter Description
Figure 550. Collection Time for NoDrxOutFail_S1apSigFail (X2) UE
Target eNB
Source eNB
EPC MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc RRC Connection Reconfiguration
Handover Request Handover Request Acknowledge
SN Status Transfer
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - NoDrxOutFail_S1apSigFail
Case 2.
③ Failure - NoDrxOutFail_S1apSigFail
S1AP RESET
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
800
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
801
Chapter 2 Counter Description Figure 551. Collection Time for NoDrxOutFail_S1apSigFail (S1) UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required
① NoDrxOutAtt
Handover Request Handover Request Acknowledg Handover Command
② NoDrxOutPrepSucc RRC Connection Reconfiguration
eNB Status Transfer
MME Status Transfer
Case 1.
S1AP UE CONTEXT RELEASE COMMAND ③ Failure - NoDrxOutFail_S1apSigFail
Case 2.
③ Failure - NoDrxOutFail_S1apSigFail
S1AP RESET
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
802
Chapter 2 Counter Description
Figure 552. Collection Time for NoDrxOutFail_X2apRoTo UE
EPC
Target eNB
Source eNB
MME
SGW
UE moves to Inter eNB Cell Measurement Report HO Decision ① NoDrxOutAtt ② NoDrxOutPrepSucc
Handover Request Handover Request Acknowledge
RRC Connection Reconfiguration SN Status Transfer
Timerout X2relocOverall
HO Execution RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release X ③ Failure - NoDrxOutFail_X2apRoTo Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
803
Chapter 2 Counter Description
Redirection by CAC This section provides statistics on the load balancing redirection by CAC preemption. Index Name
Description
cNum
Cell Id
TargetEarfcnDl
target neighbor cell frequency (EARFCN DL)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RedirLbC ac
cou nt
The cumulated number that redirection is performed to another carrier after receiving the RRC Connection Setup Complete, because the LB/CAC function is enabled when the CAC failed the RRC Connection Setup Request of new call (idle-to-active).
This counter is cumulated when redirection is performed to another carrier after the RRC connection setup complete message is received by continuing call setup since the load based CAC function is enabled when CAC fails for the new call (idle-toactive) RRC connection setup request message.
Y
CC
event
int
0~214748 3647
-
-
RedirLbC acCnt
cou nt
The cumulated collection count of redirection by CAC
This counter is cumulated when RedirLbCac is collected
-
CC
event
int
0~214748 3647
-
-
RedirLbC acTarget EarfcnDL
Targ etEa rfcn Dl
The TargetEarfcnDl of which collection is requested
This counter is updated when RedirLbCac is collected
-
OW
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
804
Chapter 2 Counter Description
Collection Time Figure 553. Collection Time for Redirection by CAC UE
Source eNB
Target eNB
MME
S/GW
UE moves to Inter eNB Cell RRC Connection Request CAC Operation RRC Connection Release 1
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
- RedirLbCac - RedirLbCacCnt - RedirLbCacTargetEarfcnDL
805
Chapter 2 Counter Description
Intra-eNB Handover per QCI This section provides statistics on the handovers between cells within the eNB. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id.
QCI_SPECIFIC
enum = QCI_1(0), QCI_5(1), QCI_8(2), QCI_9(3)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbAt t_QCI
count
The cumulated number when intra HO is judged in the handover decision after a measurement report message is received from the UE. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
This counter is cumulated when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epSucc_Q CI
count
The cumulated number when the RRC connection reconfiguration message is transmitted to the UE since preparation is completed for handover to the target cell between the inner blocks
This counter is cumulated when the time to transmit the RRC Connection Reconfiguration message is completed after HandoverRequest is transmitted to the target eNB and
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
806
Chapter 2 Counter Description Name
Unit
Description
Trigger
when intra HO is judged in the handover decision after a measurement report message is received from the UE.
HandoverRequestAcknowledge is received from the target eNB when inter X2 HO is judged in the HO decision after the MeasurementReport message is received from the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbS ucc_QCI
count
The cumulated number when the target cell normally receives the RRC connection reconfiguration complete message from the UE by performing intra HO.
This counter is cumulated when an UE context release command is normally received by the source eNB when the target eNB receives a RRC connection reconfiguration complete message from the UE after the source eNB transmits a RRCConnectionReconfiguratio n message to the UE through inter X2 HO execution.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_Cp CcTo_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the intra HO preparation procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRVCELL-STS) is changed to disabled during Inter X2 HO preparation Procedure This counter is cumulated when a call is released since
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
807
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter HO preparation procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO preparation procedure IntraEnbPr epFail_Cp CcFail_Q CI
count
The cumulated number when preparation fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the intra HO preparation procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO preparation procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_Up MacFail_Q CI
count
The cumulated number when preparation fails due to an audit mismatch between the ECCB and MAC or receiving Fail as a response message after transmitting the resource information of the target cell to the MAC during the intra HO preparation
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO preparation procedure. This counter is cumulated
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
808
Chapter 2 Counter Description Name
Unit
Description procedure.
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO preparation procedure.
IntraEnbPr epFail_Up RlcFail_Q CI
count
The cumulated number when preparation fails due to an audit mismatch between the ECCB and RLC or receiving Fail as a response message after transmitting the resource information of the target cell to the MAC during the intra HO preparation procedure.
This counter is cumulated when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_Rrc SigFail_Q CI
count
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_Cp BhCacFail _QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the intra HO preparation procedure.
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_Cp CapaCacF ail_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on call count
None
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
809
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
per cell operation or CAC based on DRB count per cell operation during the intra HO preparation procedure. IntraEnbPr epFail_Cp QosCacFa il_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the intra HO preparation procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_S1 apCuFail_ QCI
count
The cumulated number when preparation fails due to S1AP specification cause during the intra handover preparation.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRVCELL-STS) is changed to disabled during Inter X2 HO execution Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
810
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
the inter X2 HO execution procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO execution procedure IntraEnbPr epFail_S1 apLinkFail _QCI
count
The cumulated number when preparation fails since the S1AP link status is changed to 'Out of Service' during the intra HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbPr epFail_S1 apSigFail_ QCI
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the intra HO preparation procedure.
None
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_CpCcT o_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the intra HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_CpCcF ail_QCI
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter X2 HO
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
811
Chapter 2 Counter Description Name
Unit
Description
Trigger
failure during the intra HO execution procedure.
execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter X2 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
IntraEnbF ail_UpGtp Fail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the intra HO execution procedure.
None
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_UpMac Fail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the intra HO execution procedure.
This counter is cumulated when a call is released due to the S1AP specification cause during the inter X2 handover execution.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_UpRlc Fail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the MAC block during the intra HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO execution procedure This counter is cumulated when the eNB releases the call due to an SCTB reset
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
812
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
during Inter X2 HO execution procedure IntraEnbF ail_RrcHc To_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since an RRCConnectionComplete message is not received from the UE or a response message is not received from the inner blocks (PDCP, RLC, MAC) during the intra HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO execution procedure.
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_RrcSig Fail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_S1apC uFail_QCI
count
The cumulated number when execution fails since a S1AP specification cause occurs during the intra HO execution procedure.
None
Y
CC
event
int
0~2 147 483 647
-
-
IntraEnbF ail_S1apLi nkFail_QC I
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the intra HO execution procedure.
This counter is cumulated when a timeout occurs since the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE
Y
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
813
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2 147 483 647
-
-
during the Inter X2 HO execution procedure, then an UE context release message is transmitted to the source eNB but the source eNB does not receive the message. IntraEnbF ail_S1apSi gFail_QCI
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the intra HO execution procedure.
This counter is cumulated number when a call is released due to receiving the X2AP signaling during the inter X2 handover execution.
IntraEnbC nt_QCI
count
The cumulated number when intra HO is judged in the handover decision after a measurement report message is received from the UE.
This counter is cumulated when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
CC
event
int
0~2 147 483 647
-
-
IntraEnbN brCid_QCI
count
The tcID of which collection is requested
None
CC
event
int
0~2 147 483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
814
Chapter 2 Counter Description
X2 Out Handover per QCI This section provides statistics on the X2 handover between eNBs in reference with the source eNB for each cell. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id.
QCI_SPECIFIC
enum = QCI_1(0), QCI_5(1), QCI_8(2), QCI_9(3)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2Out Att_QCI
count
The cumulated number when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
This counter is cumulated when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out PrepSucc _QCI
count
The cumulated number when a RRC Connection Reconfiguration message is transmitted to the UE since a HandoverRequestAcknowled ge message is received from
This counter is cumulated when the time to transmit the RRC Connection Reconfiguration message is completed after HandoverRequest is
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
815
Chapter 2 Counter Description Name
Unit
Description
Trigger
the target eNB after a HandoverRequest message is transmitted to the target eNB due to inter X2 HO being judged in the HO decision after a MeasurementReport message is received from the UE.
transmitted to the target eNB and HandoverRequestAcknow ledge is received from the target eNB when inter X2 HO is judged in the HO decision after the MeasurementReport message is received from the UE.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2Out Succ_QCI
count
The cumulated number when an UE context release command is normally received by the source eNB when the target eNB receives a RRC connection reconfiguration complete message from the UE after the source eNB transmits a RRCConnectionReconfigurati on message to the UE through inter X2 HO execution.
This counter is cumulated when an UE context release command is normally received by the source eNB when the target eNB receives a RRC connection reconfiguration complete message from the UE after the source eNB transmits a RRCConnectionReconfigu ration message to the UE through inter X2 HO execution.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out PrepFail_ CpCcFail_ QCI
count
The cumulated number when preparation fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases a call as a
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
816
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474 83647
-
-
result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Inter X2 HO preparation Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter HO preparation procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO preparation procedure InterX2Out PrepFail_ S1apLinkF ail_QCI
count
The cumulated number when preparation fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO preparation procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service)
817
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO preparation procedure. InterX2Out PrepFail_ S1apSigF ail_QCI
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out PrepFail_ X2apCuFa il_QCI
count
The cumulated number when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out PrepFail_
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
818
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2Out PrepFail_ X2apRpTo _QCI
count
The cumulated number when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails due to a timeout that has occurred since the serving eNB has not received a handover request acknowledge message from the target eNB after transmitting a handover request message to the target eNB during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out PrepFail_ X2apSigF ail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_CpCc To_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_CpCc Fail_QCI
count
The cumulated number when execution fails due to a reset notification (eNB failure or
This counter is cumulated when the eNB releases a call due
Y
CC
event
int
0~21474 83647
-
-
X2apLinkF ail_QCI
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
819
Chapter 2 Counter Description Name
InterX2Out
Unit
count
Description
Trigger
block restart) from ECMB or ECCB resource allocation failure during the inter X2 HO execution procedure.
to ECMB reset during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Inter X2 HO execution Procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter X2 HO execution procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO execution procedure
The cumulated number when
This counter is cumulated
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474
-
820
Chapter 2 Counter Description Name
Unit
Fail_UpGt pFail_QCI
Description
Trigger
execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
InterX2Out Fail_UpMa cFail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_UpPd cpFail_QC I
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_UpRl cFail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter X2 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter X2 HO
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
821
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2Out Fail_RrcSi gFail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_S1ap CuFail_Q CI
count
The cumulated number when execution fails since a S1AP specification cause occurs during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to the S1AP specification cause during the inter X2 handover execution.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_S1ap LinkFail_Q CI
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO execution procedure This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO execution procedure
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_S1ap SigFail_Q CI
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO
Y
CC
event
int
0~21474 83647
-
-
execution procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
822
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO execution procedure. InterX2Out Fail_X2ap CuFail_Q CI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_X2ap LinkFail_Q CI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Fail_X2ap RoTo_QCI
count
The cumulated number when a timeout occurs since the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE during the Inter X2 HO execution procedure, then an UE context release message is transmitted to the source eNB but the source eNB does not receive the message.
This counter is cumulated when a timeout occurs since the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE during the Inter X2 HO execution procedure, then an UE context release message is transmitted to the source eNB but the source eNB does not
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
823
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2Out Fail_X2ap SigFail_Q CI
count
The cumulated number when a call is released due to receiving the X2AP signaling during the inter X2 handover execution.
This counter is cumulated number when a call is released due to receiving the X2AP signaling during the inter X2 handover execution.
Y
CC
event
int
0~21474 83647
-
-
InterX2Out Cnt_QCI
count
The cumulated number when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
This counter is cumulated when inter X2 HO is judged in the handover decision based on the source eNB after a measurement report message is received from the UE.
CC
event
int
0~21474 83647
-
-
InterX2Out Cid_QCI
count
The tcID of which collection is requested
None
CC
event
int
0~21474 83647
-
-
receive the message.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
824
Chapter 2 Counter Description
S1 Out Handover per QCI This section provides statistics on the S1 handovers between eNBs for each cell in reference with the source eNB. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id.
QCI_SPECIFIC
enum = QCI_1(0), QCI_5(1), QCI_8(2), QCI_9(3)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1Out Att_QCI
count
The cumulated number when inter S1 HO is judged in the HO decision after a measurement report message is received. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover attempts).
This counter is cumulated when inter S1 HO is judged in the HO decision after a measurement report message is received.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out PrepSucc _QCI
count
The cumulated number when the transmission of the RRC connection reconfiguration
This counter is cumulated when a S1 handover required message is transmitted to MME and a
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
825
Chapter 2 Counter Description Name
Unit
Description
Trigger
message to the UE is completed by receiving a S1 handover command message from MME after transmitting a S1 handover required message to MME when inter S1 HO is judged in the HO decision after a measurement report is received.
S1 handover command message is received from MME when inter S1 HO is judged in the HO decision after the measurement report message is received.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1Out Succ_QCI
count
The cumulated number when the source eNB normally receives an UE context release command message transmitted by the target eNB after inter S1 HO is executed and the source eNB transmits a RRC connection reconfiguration message to the UE and the target eNB receives a RRC connection reconfiguration complete message from the UE.
This counter is cumulated when the source eNB normally receives the UE context release command message after inter S1 HO is executed, the source eNB transmits the RRC connection reconfiguration message to the UE, the target eNB receives the RRC connection reconfiguration complete message from the UE, and the target eNB transmits the UE context release command message to the source eNB.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out PrepFail_ CpCcFail_ QCI
count
The cumulated number when preparation fails due to reset notification (eNB failure or block
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
826
Chapter 2 Counter Description Name
InterS1Out PrepFail_ S1apCuFa il_QCI
Unit
count
Description
Trigger
restart) from ECMB or by ECCB block during inter S1 handover preparation.
preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter S1 HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO preparation procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter S1 HO preparation procedure
The cumulated number when preparation fails since a S1AP specification cause occurs during the inter
This counter is cumulated when preparation fails since a S1AP specification cause occurs during the inter S1 HO preparation
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Y
CC
event
int
0~21474 83647
Granularity Formula
Hourly, Daily, Monthly Formula
827
Chapter 2 Counter Description Name
Unit
Description
Trigger
S1 HO preparation procedure.
procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1Out PrepFail_ S1apLinkF ail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1Out PrepFail_ S1apRpTo _QCI
count
The cumulated number when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1 handover required message to MME during the inter S1 HO preparation.
This counter is cumulated when preparation fails due to a timeout that has occurred since the SeNB does not receive a S1 handover command message from MME after transmitting a S1 handover required message to MME during the inter S1 HO preparation.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out PrepFail_ S1apSigF ail_QCI
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter S1 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
828
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
MME during Inter S1 HO preparation procedure. InterS1Out Fail_CpCc To_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out Fail_CpCc Fail_QCI
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELLSTS) is changed to disabled during Inter S1 HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
829
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
MAC in the execution of an audit of UE information during the inter S1 HO execution procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Inter S1 HO execution procedure InterS1Out Fail_UpGt pFail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out Fail_UpMa cFail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1Out Fail_UpPd cpFail_QC I
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
--
-
InterS1Out Fail_UpRl cFail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
830
Chapter 2 Counter Description Name
Unit
Description
Trigger
an audit mismatch occurs with the MAC block during the inter S1 HO execution procedure.
during the inter S1 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter S1 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1Out Fail_RrcSi gFail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1Out Fail_S1ap CuFail_Q CI
count
The cumulated number when execution fails since a S1AP specification cause occurs during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since a S1AP specification cause occurs during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out Fail_S1ap LinkFail_Q CI
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter S1 HO
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
831
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1Out Fail_S1ap RoTO_QC I
count
The cumulated number when timeout occurs during the inter S1 HO execution procedure since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
This counter is cumulated when timeout occurs during the inter S1 HO execution procedure since the source eNB transmits a RRC connection reconfiguration message to the UE, then the target eNB receives a RRC reconfiguration complete message from the UE and transmits an UE context release command message to the source eNB but the message is not received.
Y
CC
event
int
0~21474 83647
-
-
InterS1Out Fail_S1ap SigFail_Q CI
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from
Y
CC
event
int
0~21474 83647
-
-
execution procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
832
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
MME during Inter S1 HO execution procedure. InterS1Out Cnt_QCI
count
The cumulated number when inter S1 HO is judged in the HO decision after a measurement report message is received.
This counter is cumulated when inter S1 HO is judged in the HO decision after a measurement report message is received.
-
CC
event
int
0~21474 83647
-
-
InterS1Out Cid_QCI
count
The tcID of which collection is requested
This counter is updated when the S1 Out Handover is collected
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
833
Chapter 2 Counter Description
X2 In Handover per QCI This section provides statistics on the X2 handover between eNBs in reference with the target eNB. Index Name
Description
cNum
Cell Id
QCI_SPECIFIC
enum = QCI_1(0), QCI_5(1), QCI_8(2), QCI_9(3)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InA tt_QCI
count
The cumulated number of HandoverRequest messages received from the source eNB based on the target eNB.
This counter is cumulated when HandoverRequest messages received from the source eNB based on the target eNB.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repSucc_ QCI
count
The cumulated number of HandoverRequestAcknowl edge messages transmitted to the source eNB after a HandoverRequest message is received from the source eNB based on the target eNB.
This counter is cumulated when HandoverRequestAcknowledg e messages transmitted to the source eNB after a HandoverRequest message is received from the source eNB based on the target eNB.
Y
CC
event
int
0~21474 83647
-
-
InterX2InS ucc_QCI
count
The cumulated number of UEContextRelease messages received from the source eNB after X2 HO is completed normally
This counter is cumulated when UEContextRelease messages received from the source eNB after X2 HO is completed normally based on
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
834
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InP repFail_C pCcTo_Q CI
count
based on the target eNB.
the target eNB.
The cumulated number when preparation fails due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
This counter is cumulated when preparation fails due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_C pCcFail_Q CI
count
The cumulated number when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter X2 handover preparation.
This counter is cumulated when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter X2 handover preparation.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_U pGtpFail_ QCI
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_U pMacFail_ QCI
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the inter
This counter is cumulated when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the inter X2 HO preparation
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
835
Chapter 2 Counter Description Name
Unit
Description
Trigger
X2 HO preparation procedure.
procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InP repFail_U pPdcpFail _QCI
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_U pRlcFail_ QCI
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the RLC block during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails since Fail is received as a response message from the RLC block during the inter X2 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_C pBhCacFa il_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_C
count
The cumulated number when preparation fails due
This counter is cumulated when preparation fails due to
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
836
Chapter 2 Counter Description Name
Unit
pCapaCac Fail_QCI
Description
Trigger
to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter X2 HO preparation procedure.
the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter X2 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InP repFail_C pQosCacF ail_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_S1 apLinkFail _QCI
count
The cumulated number when preparation fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO preparation procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_S1 apSigFail_ QCI
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
837
Chapter 2 Counter Description Name
Unit
Description
Trigger
RESET from MME during the inter X2 HO preparation procedure.
message from MME during Inter X2 HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InP repFail_X2 apCuFail_ QCI
count
The cumulated number when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails since a X2AP specification cause occurs during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_X2 apLinkFail _QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2InP repFail_X2 apSigFail_ QCI
count
The cumulated number when preparation fails due to receiving X2AP reset Request during the inter X2 HO preparation procedure.
This counter is cumulated when preparation fails due to receiving X2AP reset Request during the inter X2 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_CpCcT o_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after transmitting a call control message to the protocol inner blocks (MAC, RLC, PDCP, GTP) during the
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
838
Chapter 2 Counter Description Name
Unit
Description
Trigger
(MAC, RLC, PDCP, GTP) during the inter X2 HO execution procedure.
inter X2 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InF ail_CpCcF ail_QCI
count
The cumulated number when execution fails due to a reset notification (eNB failure or block restart) from ECMB or ECCB resource allocation failure during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Inter X2 HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter X2 HO execution procedure. This counter is cumulated when a call release due to failure of ECCB resource allocation during Inter X2 HO execution procedure
Y
CC
event
int
0~21474 83647
-
-
InterX2InF
count
The cumulated number
This counter is cumulated
Y
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
839
Chapter 2 Counter Description Name
Unit
ail_UpGtp Fail_QCI
Description
Trigger
when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
when execution fails since Fail is received as a response message from the GTP block during the inter X2 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
InterX2InF ail_UpMac Fail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_UpPdc pFail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_UpRlc Fail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_RrcHc To_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a RRCConnectionComplete message is not received from the UE during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that occurs when RRCConnectionComplete is not received from the UE during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_RrcSig Fail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2InF
count
The cumulated number of
This counter is cumulated
Y
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
840
Chapter 2 Counter Description Name
Unit
ail_S1apC uFail_QCI
Description
Trigger
releases due to a S1AP specification cause that occurs during the inter X2 HO execution procedure.
when a release occurs during the inter X2 HO execution procedure due to a S1AP specification cause that occurs.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
InterX2InF ail_S1apLi nkFail_QC I
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter X2 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter X2 HO execution procedure. This counter is cumulated when the eNB releases the call due to an SCTB reset during Inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_S1apP athTo_QC I
count
The cumulated number of releases due to a timeout that has occurred since a response message is not received after a S1AP Path Switch Request message is transmitted during the inter X2 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response message is not received after a S1AP Path Switch Request message is transmitted during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_S1apSi gFail_QCI
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter X2 HO execution
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter X2 HO execution
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
841
Chapter 2 Counter Description Name
Unit
Description
Trigger
procedure.
procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter X2 HO execution procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterX2InF ail_X2apC uFail_QCI
count
The cumulated number when execution fails since a X2AP specification cause occurs during the inter X2 HO execution procedure.
This counter is cumulated when execution fails since a X2AP specification cause occurs during the inter X2 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_X2apLi nkFail_QC I
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_X2apSi gFail_QCI
count
The cumulated number of releases due to receiving a X2AP reset Request message during the inter X2 handover execution.
This counter is cumulated when a call is released due to receiving a X2AP reset Request message during the inter X2 handover execution.
Y
CC
event
int
0~21474 83647
-
-
InterX2InF ail_X2apSi gTo_QCI
count
The cumulated number of releases due to a timeout that has occurred since a X2AP signaling message is not received during the inter X2 handover execution.
This counter is cumulated when a call is released due to a timeout that has occurred since a X2AP signaling message is not received during the inter X2 handover execution.
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
842
Chapter 2 Counter Description
S1 In Handover per QCI This section provides statistics on the S1 handovers between eNBs for each cell in reference with the target eNB. Index Name
Description
cNum
Cell Id
QCI_SPECIFIC
enum = QCI_1(0), QCI_5(1), QCI_8(2), QCI_9(3)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InA tt_QCI
count
The cumulated number of S1 handover request messages received by the target eNB.
This counter is cumulated when S1 handover request messages is received by the target eNB.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP repSucc_ QCI
count
The cumulated number of S1 handover request acknowledge messages transmitted by the target eNB after it receives a S1 handover request message.
This counter is cumulated when S1 handover request acknowledge messages is transmitted by the target eNB after it receives a S1 handover request message.
Y
CC
event
int
0~21474 83647
-
-
InterS1InS ucc_QCI
count
The cumulated number of S1 handover notify messages transmitted when the handover is completed normally after the source eNB transmits a RRC connection
This counter is cumulated when S1 handover notify messages is transmitted when the handover is completed normally after the source eNB transmits a RRC connection reconfiguration message to the
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
843
Chapter 2 Counter Description Name
Unit
Description
Trigger
reconfiguration message to the UE and the target eNB normally receives a RRC connection reconfiguration complete message.
UE and the target eNB normally receives a RRC connection reconfiguration complete message.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InP rep_FailC pCcTo_Q CI
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO preparation procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailC pCcFail_Q CI
count
The cumulated numer when preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during inter S1 handover preparation.
This counter is cumulated when the eNB releases a call due to ECMB reset during Inter S1 HO preparation procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Inter S1 HO preparation procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
844
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
and between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO preparation procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Inter S1 HO preparation procedure InterS1InP rep_FailU pGtpFail_ QCI
count
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailU pMacFail_ QCI
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the MAC block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailU pPdcpFail _QCI
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO preparation procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailU
count
The cumulated number when execution fails since
This counter is cumulated when execution fails since Fail
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
845
Chapter 2 Counter Description Name
Unit
pRlcFail_ QCI
Description
Trigger
Fail is received as a response message from the RLC block during the inter S1 HO preparation procedure.
is received as a response message from the RLC block during the inter S1 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InP rep_FailC pBhCacFa il_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on backhaul bandwidth operation during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailC pCapaCac Fail_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on call count per cell operation or CAC based on DRB count per cell operation during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailC pQosCacF ail_QCI
count
The cumulated number when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter S1 HO preparation procedure.
This counter is cumulated when preparation fails due to the Call Admission Control (CAC) based on QoS operation during the inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailS1 apCuFail_
count
The cumulated number when preparation fails since a S1AP specification
This counter is cumulated when preparation fails since a S1AP specification cause
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
846
Chapter 2 Counter Description Name
Unit
QCI
Description
Trigger
cause occurs during the inter S1 HO preparation procedure.
occurs during the inter S1 HO preparation procedure.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InP rep_FailS1 apLinkFail _QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1InP rep_FailS1 apSigFail_ QCI
count
The cumulated number when preparation fails due to receiving S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET from MME during the inter S1 HO preparation procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO preparation procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter S1 HO preparation procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_CpCcT o_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
This counter is cumulated when a call is released due to a timeout that has occurred since a response is not received after a call control message is transmitted to the inner block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_CpCcF ail_QCI
count
The cumulated number when execution fails due to a reset notification (eNB
This counter is cumulated when the eNB releases a call due to ECMB reset
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
847
Chapter 2 Counter Description Name
InterS1InF ail_UpGtp Fail_QCI
Unit
count
Description
Trigger
failure or block restart) from ECMB or ECCB resource allocation failure during the inter S1 HO execution procedure.
during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases a call as a result of being notified by the ECMB that the operational state of the cell (operational State of RTRV-CELL-STS) is changed to disabled during Inter S1 HO execution procedure This counter is cumulated when a call is released since mismatches on the UE occur between the ECCB and RLC and between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO execution procedure. This counter is cumulated when a call is released due to failure of ECCB resource allocation during Inter S1 HO execution procedure
The cumulated number when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the GTP block during the inter S1 HO execution procedure.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~21474 83647
-
-
848
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterS1InF ail_UpMac Fail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the MAC block or an audit mismatch occurs with the MAC block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the MAC block during the inter S1 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and MAC in the execution of an audit of UE information during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_UpPdc pFail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the PDCP block during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_UpRlc Fail_QCI
count
The cumulated number when execution fails since Fail is received as a response message from the RLC block or an audit mismatch occurs with the MAC block during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since Fail is received as a response message from the RLC block during the inter S1 HO execution procedure. This counter is cumulated when a call is released since a mismatch on the UE occurs between the ECCB and RLC in the execution of an audit of UE information
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
849
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
during the inter S1 HO execution procedure. InterS1InF ail_RrcHc To_QCI
count
The cumulated number when a call is released due to a timeout that has occurred since RRCConnectionComplete is not received from the UE or a response message is not received from the inner blocks (PDCP, RLC, MAC) during the inter S1 HO execution procedure.
This counter is cumulated when timeout occurs since RRCConnectionComplete is not received from the UE during the inter S1 HO execution procedure. This counter is cumulated when a call is released due to a timeout that occurs since a response message is not received from the inner blocks (PDCP, RLC, MAC) during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_RrcSig Fail_QCI
count
This counter is not collected in the system
None
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_S1apC uFail_QCI
count
The cumulated number when execution fails since a S1AP specification cause occurs during the inter S1 HO execution procedure.
This counter is cumulated when execution fails since a S1AP specification cause occurs during the inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_S1apLi nkFail_QC I
count
The cumulated number when execution fails since the S1AP link status is changed to 'Out of Service' during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call because the status of the call-related S1AP link has been changed to OOS (Out Of Service) during Inter S1 HO execution procedure. This counter is cumulated
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
850
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
when the eNB releases the call due to an SCTB reset during Inter S1 HO execution procedure. InterS1InF ail_S1apSi gFail_QCI
count
The cumulated number when execution fails since S1AP UE CONTEXT RELEASE COMMAND or S1AP RESET is received from MME during the inter S1 HO execution procedure.
This counter is cumulated when the eNB releases the call as a result of receiving an S1AP UE CONTEXT RELEASE COMMAND message from MME during Inter S1 HO execution procedure. This counter is cumulated when the eNB releases the call as a result of receiving an S1AP RESET message from MME during Inter S1 HO execution procedure.
Y
CC
event
int
0~21474 83647
-
-
InterS1InF ail_S1apSi gTo_QCI
count
The cumulated number of timeouts that occur when the TeNB does not receive a S1AP MME status transfer message from MME after the SeNB transmits a S1AP eNB status transfer message to MME during the inter S1 HO execution.
This counter is cumulated when the TeNB does not receive a S1AP MME status transfer message from MME after the SeNB transmits a S1AP eNB status transfer message to MME during the inter S1 HO execution, and timeout occurred.
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
851
Chapter 2 Counter Description
HO UTRAN This section provides the statistics data for the handover between the LTE system and UTRAN system for each cell. The following shows the message flow for the PS handover procedure from the E-UTRAN to the UTRAN.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
852
Chapter 2 Counter Description Figure 554. PS Handover Procedure from E-UTRAN to UTRAN. UE
Source eNB
Target RNS
Downlink/Uplink data
Source MME
Source S-GW
Target SGSN
Target S-GW
P-GW
Downlink/Uplink data
Downlink/Uplink data
1) Handover Initiation 2) HANDOVER REQUIRED 3) FORWARD RELOCATION REQUEST 4) Create Session Request/Response 5) RELOCATION REQUEST 6) RELOCATION REQUEST ACKNOWLEDGE 7) Create Indirect Data Forwarding Tunnel Request/Response 8) FORWARD RELOCATION RESPONSE 9) Create Indirect Data Forwarding Tunnel Request/Response 10) HANDOVER COMMAND 11) Mobility from E- UTRAN Complete Indirect data forwarding Indirect data forwarding 12) HO to UTRAN Complete
13) RELOCATION COMPLETE 14) FORWARD RELOCATION COMPLETE NOTIFICATION 15) FORWARD RELOCATION COMPLETE ACKNOWLEDGE 16) MODIFY BEARER REQUEST 17) Modify Bearer Request/Response 18) MODIFY BEARER Response
Downlink/Uplink data
Downlink/Uplink data
Downlink/Uplink data
19) Routing Area Update procedure 20) S1 Release 21) Delete Session Request/Response 22) Create Indirect Data Forwarding Tunnel Request/Response 23) Create Indirect Data Forwarding Tunnel Request/Response
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
853
Chapter 2 Counter Description Step
Description
1)
The source eNB determines the PS handover to the UTRAN. This decision is made according to the measurement report received from the UE.
2)
The source eNB transmits the HANDOVER REQUIRED message to the MME. The source eNB then includes the source RNC to target RNC transparent container IE information in the message for relaying the necessary information to the target RNC.
3)-4)
The source MME recognizes the handover from the target ID IE of the HANDOVER REQUIRED message to the UTRAN and transmits the FORWARD RELOCATION REQUEST message to the target SGSN. The target SGSN determines whether to change the S-GW. If change is required, it carries out the Create Session Request/Response procedure with a new S-GW.
5)-6)
The target SGSN transmits the RELOCATION REQUEST message to the target RNC to request resource allocation for the target RNC. The target RNC performs CAC and resource allocation for each RAB for which handover is requested, and transmits to the target SGSN the RELOCATION REQUEST ACKNOWLEDGE message that encapsulates the result. The RELOCATION REQUEST ACKNOWLEDGE message encapsulates the Target RNC to Source RNC Transparent Container IE to be transmitted to the source eNB.
7)-9)
To perform the forwarding tunnel setup, the target SGSN performs the Create Indirect Data Forwarding Tunnel Request/Response procedure with target S-GW and transmits the FORWARD RELOCATION RESPONSE message to the source MME. To perform the forwarding tunnel setup, the source MME carries out the Create Indirect Data Forwarding Tunnel Request/Response procedure with the source S-GW.
10)-11)
The source MME transmits the HANDOVER COMMAND message to the source eNB to complete the handover preparation procedure to the target UTRAN. The source eNB configures the MOBILITY FROM E-UTRAN COMMAND containing the Target RNC to Source RNC Transparent Container IE in the HANDOVER COMMAND message and transmits it to the UE to request the PS handover to the UTRAN.
12)
The UE performs synchronization with the target UTRAN and connects to the target cell via the RACH. After UE is successfully connected to the target cell, UE transmits the HANDOVER TO UTRAN COMPLETE message to the target UTRAN to complete the handover procedure.
13)-15)
The target RNC transmits the RELOCATION COMPLETE message to the target SGSN to notify that the handover procedure from the UE to the UTRAN has been completed successfully. The target SGSN transmits the FORWARD RELOCATION COMPLETE NOTIFICATION message to the source MME. At this time, the source MME operates the waiting timer for releasing the resource of the E-UTRAN and transmits the FORWARD RELOCATION COMPLETE ACKNOWLEDGE response message to the target SGSN. The target SGSN operates the waiting timer for releasing the forwarding tunnel at the time when the source MME receives the response message.
16)-18)
The target SGSN transmits the Modify Bearer Request message for each PDN connection to the target S-GW. Subsequent downlink packets are then transmitted from the S-GW to the target RNC. The target S-GW performs the Modify Bearer Request/Response procedure with the P-GW and transmits the Modify Bearer Response message to the target SGSN.
19)
When UE satisfies the conditions specified in section 5.5.2.1 of TS 23.401, the Routing Area Update procedure starts.
20)-23)
When the timer at Step 14) expires, the source MME requests the source eNB and the source S-GW to release the resources. When the timer at Step 15) expires, the target SGSN releases the resources release allocated for forwarding tunnel with the target S-GW.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
854
Chapter 2 Counter Description
Inter-RAT UTRAN PS Out Handover This section provides statistics on the outgoing handover between the LTE and UTRAN systems for each cell. The collection time for the HO attempt, the HO preparation and the HO success statistics is the same as that for the S1 handover out statistics. Index Name
Description
cNum
Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RatUtranOutAtt
count
LTE to inter-RAT UTRAN handover attempt count.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutPrepSuc c
count
LTE to inter-RAT UTRAN handover preparation success count
Y
CC
event
int
0~2147483647
-
-
RatUtranOutSucc
count
LTE to inter-RAT UTRAN handover execution success count
Y
CC
event
int
0~2147483647
-
-
RatUtranOutPrepFail _CpCcFail
count
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutPrepFail _S1apCuFail
count
Preparation fails due to S1AP specification cause during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutPrepFail _S1apLinkFail
count
Preparation fails due to S1 SCTP link failure during the UTRAN
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
855
Chapter 2 Counter Description Name
Unit
RatUtranOutPrepFail _S1apRpTo
count
RatUtranOutPrepFail _S1apSigFail
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
count
Preparation fails due to receiving S1AP signaling during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Cp CcTo
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Cp CcFail
count
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Up GtpFail
count
A call is released due to the failure in the GTP block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Up MacFail
count
A call is released due to the failure in the MAC block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Up PdcpFail
count
A call is released due to the failure in the PDCP block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Up RlcFail
count
A call is released due to the failure in the RLC block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_Rrc SigFail
count
A call is released due to receiving RRC signaling during the UTRAN
Y
CC
event
int
0~2147483647
-
-
handover preparation.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
856
Chapter 2 Counter Description Name
Unit
RatUtranOutFail_S1a pCuFail
count
RatUtranOutFail_S1a pLinkFail
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
A call is released due to the S1AP specification cause during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
count
A call is released due to the S1 SCTP link failure during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_S1a pRoTo
count
A call is released due to S1AP relocoverall timeout (not received) during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatUtranOutFail_S1a pSigFail
count
A call is released due to receiving S1AP signaling during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
handover execution.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
857
Chapter 2 Counter Description
Collection Time (Success) Figure 555. Collection Time for Inter-RAT UTRAN PS Handover Out UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command Prepare
Mobility From EUTRA Command UE Context Release Command UE Context Release Complete
Call Release
3
Success
For the inter-RAT UTRAN Handover Out statistics, an Attempt is counted when the S1 Handover Required message is transmitted after the UTRAN handover decision following the Measurement Report message arrival. A Prepare is counted when the Mobility Eutra Command message is transmitted to the UE. A Success is counted when the handover is completed and the MME transmits the UE Context Release Complete message. If the procedure from 1 to 2 fails, it is counted as a Prepare Fail and returns the cause value. When the procedure from 2 to 3fails, it is counted as an Inter RAT UTRAN HO Out Fail and returns the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
858
Chapter 2 Counter Description
Collection Time (Failure) Figure 556. Collection Time for Inter-RAT UTRAN PS Handover Out UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Failure - RatUtranOutPrepFail_CpCcFail - RatUtranOutPrepFail_S1apLinkFail - RatUtranOutPrepFail_S1apSigFail Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
859
Chapter 2 Counter Description Figure 557. Collection Time for RatUtranOutPrepFail_S1apCuFail UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required
Handover Preparation Fail
2
Failure - RatUtranOutPrepFail_S1apCuFail
2
Failure - RatUtranOutPrepFail_S1apRpTo
Figure 558. Collection Time for RatUtranOutPrepFail_S1apRpTo UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required
(Handover Command)
X
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
860
Chapter 2 Counter Description Figure 559. Collection Time for Inter-RAT UTRAN PS Handover Out UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command Prepare
Mobility From EUTRA Command
3
Failure - RatUtranOutFail_CpCcTo - RatUtranOutFail_CpCcFail - RatUtranOutFail_UpGtpFail - RatUtranOutFail_UpMacFail - RatUtranOutFail_UpPdcpFail - RatUtranOutFail_UpRlcFail - RatUtranOutFail_S1apCuFail - RatUtranOutFail_S1apLinkFail - RatUtranOutFail_S1apSigFail
UE Context Release Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
861
Chapter 2 Counter Description
Figure 560. Collection Time for RatUtranOutFail_RrcSigFail UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command Prepare
Mobility From EUTRA Command Rrc Connection Request
3
Failure - RatUtranOutFail_RrcSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
862
Chapter 2 Counter Description Figure 561. Collection Time for RatUtranOutFail_S1apRoTo UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Prepare
Mobility From EUTRA Command
Handover Command UE Context Release Command
X
3
Failure - RatUtranOutFail_S1apRoTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
863
Chapter 2 Counter Description
Inter-RAT UTRAN PS In Handover This section provides statistics on the handover between the LTE system and UTRAN system for each cell. Index Name
Description
cNum
Cell Id
HoCause
Handover cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RatUtranInAtt
count
Inter-RAT UTRAN to LTE handover attempt count.
Y
CC
event
int
0~2147483647
-
-
RatUtranInPrepSuc c
count
Inter-RAT UTRAN to LTE handover preparation success count.
Y
CC
event
int
0~2147483647
-
-
RatUtranInSucc
count
Inter-RAT UTRAN to LTE handover execution success count.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _CpCcTo
count
Preparation fails due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _CpCcFail
count
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _UpGtpFail
count
Preparation fails due to internal failure in the GTP block during the UTRAN
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
864
Chapter 2 Counter Description Name
Unit
RatInPrepFailUtran _UpMacFail
count
RatInPrepFailUtran _UpPdcpFail
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Preparation fails due to internal failure in the MAC block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
count
Preparation fails due to internal failure in the PDCP block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _UpRlcFail
count
Preparation fails due to internal failure in the RLC block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _CpBhCacFail
count
Preparation fails due to insufficient backhaul-based eNB resources during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _CpCapaCacFail
count
Preparation fails due to insufficient capacity-based eNB resources during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _CpQosCacFail
count
Preparation fails due to insufficient QoS-based eNB resources during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _S1apCuFail
count
Preparation fails due to S1AP specification cause during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _S1apLinkFail
count
Preparation fails due to S1 SCTP link failure during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInPrepFailUtran _S1apSigFail
count
Preparation fails due to receiving S1AP signaling during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_CpC cTo
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN
Y
CC
event
int
0~2147483647
-
-
handover preparation.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
865
Chapter 2 Counter Description Name
Unit
RatInFailUtran_CpC cFail
count
RatInFailUtran_UpG tpFail
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.
Y
CC
event
int
0~2147483647
-
-
count
A call is released due to the failure in the GTP block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_Up MacFail
count
A call is released due to the failure in the MAC block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_UpP dcpFail
count
A call is released due to the failure in the PDCP block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_UpR lcFail
count
A call is released due to the failure in the RLC block during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_Rrc HcTo
count
A call is released due to HO command timeout (not received) during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_Rrc SigFail
count
A call is released due to receiving RRC signaling during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_S1a pCuFail
count
A call is released due to the S1AP specification cause during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_S1a pLinkFail
count
A call is released due to the S1 SCTP link failure during the UTRAN handover execution.
Y
CC
event
int
0~2147483647
-
-
RatInFailUtran_S1a
count
A call is released due to receiving
Y
CC
event
int
0~2147483647
-
-
handover execution.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
866
Chapter 2 Counter Description Name
Unit
pSigFail RatInFailUtran_S1a pSigTo
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
S1AP signaling during the UTRAN handover execution. count
A call is released due to S1AP signaling timeout (not received) during the UTRAN handover execution.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
867
Chapter 2 Counter Description
Collection Time (Success) Figure 562. Collection Time for Inter-RAT UTRAN PS Handover In UE
Target eNB
Attempt
1
Prepare
2
MME
Handover Request
Handover Request Acknowledge
RRC Connection Reconfiguration Complete (Handover to E-UTRAN Complete) Success
3
Handover Notify
For the Inter-RAT UTRAN In statistics, an Attempt is counted when the target eNB receives the S1 Handover Request message. A Prepare is counted after the target eNB transmits the S1 Handover Request Acknowledge message. The target eNB receives the RRC Connection Reconfiguration Complete message from the UE. A Success is counted after the handover is successfully completed and the S1 Handover Notify message is transmitted to the MME. If the procedure from 1 to 2 fails, it is counted as a Prepare Fail, returning the cause value, and when the procedure from 2 to 3 fails, it is counted as an Inter-RAT UTRAN In Fail and returns the cause value.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
868
Chapter 2 Counter Description
Collect Time (Failure) Figure 563. Collection Time for Inter-RAT UTRAN PS Handover In UE
Target eNB
Attempt
MME
Handover Request
1 2
Failure - RatInPrepFailUtran_CpCcTo - RatInPrepFailUtran_CpCcFail - RatInPrepFailUtran_UpGtpFail - RatInPrepFailUtran_UpMacFail - RatInPrepFailUtran_UpPdcpFail - RatInPrepFailUtran_UpRlcFail - RatInPrepFailUtran_CpBhCacFail - RatInPrepFailUtran_CpCapaCacFail - RatInPrepFailUtran_CpQosCacFail - RatInPrepFailUtran_S1apLinkFail - RatInPrepFailUtran_S1apSigFail - RatInPrepFailUtran_S1apCuFail - RatInFailUtran_CpCcFail Handover Failure
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
869
Chapter 2 Counter Description
Figure 564. Collection Time for Inter-RAT UTRAN PS Handover In UE
Target eNB
Attempt
1
Prepare
2
MME
Handover Request
Handover Request Acknowledge
RRC Connection Reconfiguration Complete (Handover to E-UTRAN Complete) 3
Failure - RatInFailUtran_CpCcTo - RatInFailUtran_UpGtpFail - RatInFailUtran_UpMacFail - RatInFailUtran_UpPdcpFail - RatInFailUtran_UpRlcFail - RatInFailUtran_RrcHcTo - RatInFailUtran_S1apCuFail - RatInFailUtran_S1apLinkFail - RatInFailUtran_S1apSigFail - RatInFailUtran_S1apSigTo
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
870
Chapter 2 Counter Description
Figure 565. Collection Time for RatInFailUtran_RrcSigFail UE
Target eNB
Attempt
1
Prepare
2
MME
Handover Request
Handover Request Acknowledge
Rrc Connection Request 3
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Failure - RatInFailUtran_RrcSigFail
871
Chapter 2 Counter Description
UTRAN SRVCC This section provides the statistics data for the SRVCC handover to UTRAN. Index Name
Description
cNum
Cell Id
HOCause
Handover Cause 0: Handover desirable for radio reasons 1: reserved
HOIndication
Information on classifying PS_CS, and CS_only upon performing the handover
Statistic Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UtranSrvccOutAtt
count
UTRAN SRVCC Handover attempt count
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutPrepSuc c
count
UTRAN SRVCC Handover preparation success count
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutSucc
count
UTRAN SRVCC Handover execution success count
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutPrepFail_ CpCcFail
count
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC preparation.
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutPrepFail_ S1apCuFail
count
Preparation fails due to S1AP specification cause during the
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
872
Chapter 2 Counter Description Name
Unit
UtranSrvccOutPrepFail_ S1apLinkFail
count
UtranSrvccOutPrepFail_ S1apRpTo
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Preparation fails due to S1 SCTP link failure during the UTRAN SRVCC preparation.
Y
CC
event
int
0~2147483647
-
-
count
Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN SRVCC preparation.
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutPrepFail_ S1apSigFail
count
Preparation fails due to receiving S1AP signaling during the UTRAN SRVCC preparation
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_CpC cTo
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_CpC cFail
count
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_UpG tpFail
count
A call is released due to the failure in the GTP block during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_UpM acFail
count
A call is released due to the failure in the MAC block during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_UpP dcpFail
count
A call is released due to the failure in the PDCP block during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_UpR
count
A call is released due to the failure
Y
CC
event
int
0~2147483647
-
-
UTRAN SRVCC preparation
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
873
Chapter 2 Counter Description Name
Unit
lcFail
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
in the RLC block during the UTRAN SRVCC execution
UtranSrvccOutFail_Rrc SigFail
count
A call is released due to receiving RRC signaling during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_S1a pCuFail
count
A call is released due to the S1AP specification cause during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_S1a pLinkFail
count
A call is released due to the S1 SCTP link failure during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_S1a pRoTo
count
A call is released due to S1AP relocoverall timeout (not received) during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
UtranSrvccOutFail_S1a pSigFail
count
A call is released due to receiving S1AP signaling during the UTRAN SRVCC execution
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
874
Chapter 2 Counter Description
Collection Time (Success) Figure 566. Collection Time for UTRAN SRVCC UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command Prepare
Mobility From EUTRA Command UE Context Release Command UE Context Release Complete
Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
3
Success
875
Chapter 2 Counter Description
Collection Time (Failure) Figure 567. Collection Time for UTRAN SRVCC UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Failure - UtranSrvccOutPrepFail_CpCcFail - UtranSrvccOutPrepFail_S1apLinkFail - UtranSrvccOutPrepFail_S1apSigFail Handover Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
876
Chapter 2 Counter Description
Figure 568. Collection Time for UtranSrvccOutPrepFail_S1apCuFail UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required
Handover Preparation Fail
2
Failure - UtranSrvccOutPrepFail_S1apCuFail
2
Failure - UtranSrvccOutPrepFail_S1apRpTo
Figure 569. Collection Time for UtranSrvccOutPrepFail_S1apRpTo UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required
(Handover Command)
X
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
877
Chapter 2 Counter Description
Figure 570. Collection Time for UTRAN SRVCC UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command Prepare
Mobility From EUTRA Command
3
Failure - UtranSrvccOutFail_CpCcTo - UtranSrvccOutFail_CpCcFail - UtranSrvccOutFail_UpGtpFail - UtranSrvccOutFail_UpMacFail - UtranSrvccOutFail_UpPdcpFail - UtranSrvccOutFail_UpRlcFail - UtranSrvccOutFail_S1apCuFail - UtranSrvccOutFail_S1apLinkFail - UtranSrvccOutFail_S1apSigFail
UE Context Release Command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
878
Chapter 2 Counter Description
Figure 571. Collection Time for UtranSrvccOutFail_RrcSigFail UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command Prepare
Mobility From EUTRA Command Rrc Connection Request
3
Failure - UtranSrvccOutFail_RrcSigFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
879
Chapter 2 Counter Description Figure 572. Collection Time for UtranSrvccOutFail_S1apRoTo UE
Source eNB
MME
Measurement Report HO Decision
1
Attempt
Handover Required 2
Handover Command
Prepare
Mobility From EUTRA Command
UE Context Release Command
X
3
Failure - UtranSrvccOutFail_S1apRoTo
CSFB PS Out Handover This section provides statistics on the CSFB with PS handover count between the LTE and UTRAN for each cell. Index Name
Description
cNum
Cell Id
CSFBIndicator
CSFB Indicator 0: Normal 1: High Priority
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CSFBPsHoUtranAt
count
Attempt count for CSFB with inter-
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
880
Chapter 2 Counter Description Name
Unit
t
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RAT UTRAN PS handover.
CSFBPsHoUtranPr epSucc
count
Success count for CSFB with interRAT UTRAN PS handover preparation.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranS ucc
count
Success count for CSFB with interRAT UTRAN PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranPr epFail_CpCcFail
count
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the CSFB PS handover preparation.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranPr epFail_S1apCuFail
count
Preparation fails due to S1AP specification cause during the CSFB PS handover preparation.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranPr epFail_S1apLinkFa il
count
Preparation fails due to S1 SCTP link failure during the CSFB PS handover preparation.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranPr epFail_S1apRpTo
count
Preparation fails due to S1AP relocprep timeout (not received) during the CSFB PS handover preparation.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranPr epFail_S1apSigFai l
count
Preparation fails due to receiving S1AP signaling during the CSFB PS handover preparation.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_CpCcTo
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_CpCcFail
count
A call is released due to reset notification (eNB failure or block
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
881
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
restart) from ECMB or by the ECCB block during the CSFB PS handover execution. CSFBPsHoUtranF ail_UpGtpFail
count
A call is released due to the failure in the GTP block during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_UpMacFail
count
A call is released due to the failure in the MAC block during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_UpPdcpFail
count
A call is released due to the failure in the PDCP block during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_UpRlcFail
count
A call is released due to the failure in the RLC block during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_RrcSigFail
count
A call is released due to receiving RRC signaling during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_S1apCuFail
count
A call is released due to the S1AP specification cause during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_S1apLinkFail
count
A call is released due to the S1 SCTP link failure during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_S1apRoTo
count
A call is released due to S1AP relocoverall timeout (not received) during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
CSFBPsHoUtranF ail_S1apSigFail
count
A call is released due to receiving S1AP signaling during the CSFB PS handover execution.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
882
Chapter 2 Counter Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
883
Chapter 2 Counter Description
Collection Time (Success) Figure 573. Collection Time for CSFB PS Handover Out UE
Source eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Report Handover Required 1
Attempt
Mobility From EUTRA Command
Handover Command
2
Prepare
UE Context Release Command 3
Success
UE Context Release Complete
Call Release
For the CSFB PS handover UTRAN out statistics, when the S1 Handover Required message can be transmitted to the MME after the handover UTRAN decision following the Measurement Report message arrival, it is counted as an Attempt. When the S1 Handover Command message is received from the MME, it is counted as a Prepare. The source eNB transmits the Mobility from EUTRA Command message to the UE, and the MME transmits the S1 UE Context Release Command message to the source eNB. At this point, the source eNB is counted as a Success. If the procedure from 1 to 2 fails, it is counted as a Prepare Fail, returning the cause value. When the procedure from 2 to 3 fails, it is counted as a CSFB PS HO UTRAN Out and returns the cause value
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
884
Chapter 2 Counter Description
Collection Time (Failure) Figure 574. Collection Time for CSFBPsHoUtranPrepFail_S1apCuFail UE
eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Handover Required 1
Attempt
2
Preparation Failure
Handover Preparation Failure
CSFBPsHoUtranPrepFail_S1apCuFail
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
885
Chapter 2 Counter Description Figure 575. Collection Time for CSFB PS Out Handover UE
eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Report Handover Required 1
Attempt
2
Preparation Failure - CSFBPsHoUtranPrepFail_CpCcFail - CSFBPsHoUtranPrepFail_S1apLinkFail - CSFBPsHoUtranPrepFail_S1apSigFail
Figure 576. Collection Time for CSFBPsHoUtranPrepFail_S1apRpTo UE
eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Report Handover Required
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Attempt
2
Preparation Failure - CSFBPsHoUtranPrepFail_S1apRpTo
Handover Preparation Failure
886
Chapter 2 Counter Description Figure 577. Collection Time for CSFBPsHoUtranFail_S1apRoTo UE
eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Report Handover Required 1
Attempt
Mobility From EUTRA Command
Handover Command 2
Preparation Handover Preparation Failure
3
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Success Failure - CSFBPsHoUtranFail_S1apRoTo
887
Chapter 2 Counter Description
Figure 578. Collection Time for CSFB PS Out Handover UE
eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Report Handover Required 1
Attempt
Mobility From EUTRA Command
3
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Success Failure
Handover Command 2
Preparation
- CSFBPsHoUtranFail_CpCcTo - CSFBPsHoUtranFail_CpCcFail - CSFBPsHoUtranFail_UpGtpFail - CSFBPsHoUtranFail_UpMacFail - CSFBPsHoUtranFail_UpPdcpFail - CSFBPsHoUtranFail_UpRlcFail - CSFBPsHoUtranFail_RrcSigFail - CSFBPsHoUtranFail_S1apCuFail - CSFBPsHoUtranFail_S1apLinkFail - CSFBPsHoUtranFail_S1apSigFail
888
Chapter 2 Counter Description
CSFB Redirection Out This section provides statistics on the CSFB with Redirection count between the LTE and UTRAN for each cell. Index Name
Description
cNum
Cell Id
CSFBIndicator
CSFB Indicator 0: Normal 1: High priority
SIBOwn
Indicates whether UTRAN SI information is included. 0: Not included 1: Included
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CSFBRedirUtranAtt
count
CSFB with Redirection to interRAT UTRAN attempt count
Y
CC
event
int
0~2147483647
-
-
CSFBRedirUtranPr epSucc
count
CSFB with Redirection to interRAT UTRAN preparation success count.
Y
CC
event
int
0~2147483647
-
-
CSFBRedirUtranSu cc
count
CSFB with Redirection to interRAT UTRAN execution success count.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
889
Chapter 2 Counter Description
Collection Time Figure 579. Collection Time for CSFB Redirection Out UE
Source eNB
MME
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind)
1
Attempt
Initial Context Setup Response or UE Context Modification Response
Redirection 2
Prepare
RRC connection Release (with Redirection Info)
3
Success
Call Release
For the CSFB with Redirection UTRAN statistics, when the Initial Context Setup Request or the UE Context Modification Request message received has the CSFB Indicator IE, according to which CSFB is decided, it is counted as an Attempt. When preparation is completed in the eNB, it is counted as a Prepare. A Success is counted when the RRC Connection Release message is transmitted to the UE for redirection.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
890
Chapter 2 Counter Description
PS Redirection UTRAN Out This section provides statistics on the PS redirection between the LTE system and UTRAN for each cell. Index Name
Description
cNum
Cell Id
HOCause
Handover Cause 0: Handover desirable for radio reasons 1: reserved
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PsRedirAttUtran
count
PS Redirection to Inter RAT UTRAN attempt count
Y
CC
event
int
0~2147483647
-
-
PsRedirPrepSuccUtra n
count
PS Redirection to Inter RAT UTRAN preparation success count
Y
CC
event
int
0~2147483647
-
-
PsRedirSuccUtran
count
PS Redirection to Inter RAT UTRAN execution success count
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
891
Chapter 2 Counter Description
Collection Time Figure 580. Collection Time for PS Redirection UTRAN Out UE
eNB
MME
Measurement Report 1
Attempt
Redirection 2
Prepare
3
Success
RRC Connection Release (with Redirection Info)
UE Context Release Request Call Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
892
Chapter 2 Counter Description
Integrated UTRAN Out This section provides the statistics data for integrated outgoing handover between the LTE and UTRAN systems for each Eutran_Cell_Idl/RNC_Id/UTRAN_Cell_id. The collection time for the HO attempt, the HO preparation and the HO success statistics is the same as that for the S1 handover out statistics. Index Name
Description
cNum
Cell ID
RncID
RNC ID
UtranCellID
UTRAN cell ID
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RatUtranOutAtt_Int eg
count
LTE to inter-RAT UTRAN handover attempt count.
LTE to inter-RAT UTRAN handover attempt.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutPrepS ucc_Integ
count
LTE to inter-RAT UTRAN handover preparation success count
LTE to inter-RAT UTRAN handover preparation success
-
CC
event
int
0~21474 83647
-
-
RatUtranOutSucc_I nteg
count
LTE to inter-RAT UTRAN handover execution success count
LTE to inter-RAT UTRAN handover execution success
-
CC
event
int
0~21474 83647
-
-
RatUtranOutPrepF ail_CpCcFail_Integ
count
Preparation fails due to reset notification (eNB failure or block restart)
Preparation fails due to reset notification (eNB failure or block restart)
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
893
Chapter 2 Counter Description Name
Unit
Description
Trigger
from ECMB or by the ECCB block during the UTRAN handover preparation.
from ECMB or by the ECCB block during the UTRAN handover preparation.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RatUtranOutPrepF ail_S1apCuFail_Int eg
count
Preparation fails due to S1AP specification cause during the UTRAN handover preparation.
Preparation fails due to S1AP specification cause during the UTRAN handover preparation.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutPrepF ail_S1apLinkFail_In teg
count
Preparation fails due to S1 SCTP link failure during the UTRAN handover preparation.
Preparation fails due to S1 SCTP link failure during the UTRAN handover preparation.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutPrepF ail_S1apRpTo_Inte g
count
Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN handover preparation.
Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN handover preparation.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutPrepF ail_S1apSigFail_Int eg
count
Preparation fails due to receiving S1AP signaling during the UTRAN handover preparation.
Preparation fails due to receiving S1AP signaling during the UTRAN handover preparation.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_C pCcTo_Integ
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover execution.
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_C pCcFail_Integ
count
A call is released due to reset notification (eNB
A call is released due to reset notification (eNB
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
894
Chapter 2 Counter Description Name
Unit
Description
Trigger
failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.
failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RatUtranOutFail_U pGtpFail_Integ
count
A call is released due to the failure in the GTP block during the UTRAN handover execution.
A call is released due to the failure in the GTP block during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_U pMacFail_Integ
count
A call is released due to the failure in the MAC block during the UTRAN handover execution.
A call is released due to the failure in the MAC block during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_U pPdcpFail_Integ
count
A call is released due to the failure in the PDCP block during the UTRAN handover execution.
A call is released due to the failure in the PDCP block during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_U pRlcFail_Integ
count
A call is released due to the failure in the RLC block during the UTRAN handover execution.
A call is released due to the failure in the RLC block during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_R rcSigFail_Integ
count
A call is released due to receiving RRC signaling during the UTRAN handover execution.
A call is released due to receiving RRC signaling during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_S 1apCuFail_Integ
count
A call is released due to the S1AP specification cause during the
A call is released due to the S1AP specification cause during the
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
895
Chapter 2 Counter Description Name
Unit
Description
Trigger
UTRAN handover execution.
UTRAN handover execution.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RatUtranOutFail_S 1apLinkFail_Integ
count
A call is released due to the S1 SCTP link failure during the UTRAN handover execution.
A call is released due to the S1 SCTP link failure during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_S 1apRoTo_Integ
count
A call is released due to S1AP relocoverall timeout (not received) during the UTRAN handover execution.
A call is released due to S1AP relocoverall timeout (not received) during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
RatUtranOutFail_S 1apSigFail_Integ
count
A call is released due to receiving S1AP signaling during the UTRAN handover execution.
A call is released due to receiving S1AP signaling during the UTRAN handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranAtt _Integ
count
Attempt count for CSFB with inter-RAT UTRAN PS handover.
Attempt for CSFB with inter-RAT UTRAN PS handover.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranPr epSucc_Integ
count
Success count for CSFB with inter-RAT UTRAN PS handover preparation.
Success for CSFB with inter-RAT UTRAN PS handover preparation.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranSu cc_Integ
count
Success count for CSFB with inter-RAT UTRAN PS handover execution.
Success for CSFB with inter-RAT UTRAN PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranPr epFail_CpCcFail_In teg
count
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
896
Chapter 2 Counter Description Name
Unit
Description
Trigger
CSFB PS handover preparation.
CSFB PS handover preparation.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CSFBPsHoUtranPr epFail_S1apCuFail _Integ
count
Preparation fails due to S1AP specification cause during the CSFB PS handover preparation.
Preparation fails due to S1AP specification cause during the CSFB PS handover preparation.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranPr epFail_S1apLinkFa il_Integ
count
Preparation fails due to S1 SCTP link failure during the CSFB PS handover preparation.
Preparation fails due to S1 SCTP link failure during the CSFB PS handover preparation.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranPr epFail_S1apRpTo_ Integ
count
Preparation fails due to S1AP relocprep timeout (not received) during the CSFB PS handover preparation.
Preparation fails due to S1AP relocprep timeout (not received) during the CSFB PS handover preparation.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranPr epFail_S1apSigFail _Integ
count
Preparation fails due to receiving S1AP signaling during the CSFB PS handover preparation.
Preparation fails due to receiving S1AP signaling during the CSFB PS handover preparation.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_CpCcTo_Integ
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the CSFB PS handover execution.
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_CpCcFail_Integ
count
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
897
Chapter 2 Counter Description Name
Unit
Description
Trigger
CSFB PS handover execution.
CSFB PS handover execution.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CSFBPsHoUtranFa il_UpGtpFail_Integ
count
A call is released due to the failure in the GTP block during the CSFB PS handover execution.
A call is released due to the failure in the GTP block during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_UpMacFail_Integ
count
A call is released due to the failure in the MAC block during the CSFB PS handover execution.
A call is released due to the failure in the MAC block during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_UpPdcpFail_Inte g
count
A call is released due to the failure in the PDCP block during the CSFB PS handover execution.
A call is released due to the failure in the PDCP block during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_UpRlcFail_Integ
count
A call is released due to the failure in the RLC block during the CSFB PS handover execution.
A call is released due to the failure in the RLC block during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_RrcSigFail_Integ
count
A call is released due to receiving RRC signaling during the CSFB PS handover execution.
A call is released due to receiving RRC signaling during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_S1apCuFail_Inte g
count
A call is released due to the S1AP specification cause during the CSFB PS handover execution.
A call is released due to the S1AP specification cause during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa il_S1apLinkFail_Int eg
count
A call is released due to the S1 SCTP link failure during the CSFB PS handover execution.
A call is released due to the S1 SCTP link failure during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
CSFBPsHoUtranFa
count
A call is released due to S1AP relocoverall
A call is released due to S1AP relocoverall
-
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
898
Chapter 2 Counter Description Name
Unit
il_S1apRoTo_Integ
Description
Trigger
timeout (not received) during the CSFB PS handover execution.
timeout (not received) during the CSFB PS handover execution.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
CSFBPsHoUtranFa il_S1apSigFail_Inte g
count
A call is released due to receiving S1AP signaling during the CSFB PS handover execution.
A call is released due to receiving S1AP signaling during the CSFB PS handover execution.
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutAtt_I nteg
count
UTRAN SRVCC Handover attempt count
UTRAN SRVCC Handover attempt
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutPrep Succ_Integ
count
UTRAN SRVCC Handover preparation success count
UTRAN SRVCC Handover preparation success
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutSucc _Integ
count
UTRAN SRVCC Handover execution success count
UTRAN SRVCC Handover execution success
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutPrep Fail_CpCcFail_Inte g
count
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC preparation.
Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC preparation.
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutPrep Fail_S1apCuFail_In teg
count
Preparation fails due to S1AP specification cause during the UTRAN SRVCC preparation
Preparation fails due to S1AP specification cause during the UTRAN SRVCC preparation
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutPrep Fail_S1apLinkFail_I nteg
count
Preparation fails due to S1 SCTP link failure during the UTRAN SRVCC preparation.
Preparation fails due to S1 SCTP link failure during the UTRAN SRVCC preparation.
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
899
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UtranSrvccOutPrep Fail_S1apRpTo_Int eg
count
Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN SRVCC preparation.
Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN SRVCC preparation.
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutPrep Fail_S1apSigFail_I nteg
count
Preparation fails due to receiving S1AP signaling during the UTRAN SRVCC preparation
Preparation fails due to receiving S1AP signaling during the UTRAN SRVCC preparation
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ CpCcTo_Integ
count
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN SRVCC execution
A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ CpCcFail_Integ
count
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC execution
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ UpGtpFail_Integ
count
A call is released due to the failure in the GTP block during the UTRAN SRVCC execution
A call is released due to the failure in the GTP block during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ UpMacFail_Integ
count
A call is released due to the failure in the MAC block during the UTRAN SRVCC
A call is released due to the failure in the MAC block during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
900
Chapter 2 Counter Description Name
Unit
UtranSrvccOutFail_ UpPdcpFail_Integ
count
UtranSrvccOutFail_ UpRlcFail_Integ
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
A call is released due to the failure in the PDCP block during the UTRAN SRVCC execution
A call is released due to the failure in the PDCP block during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
count
A call is released due to the failure in the RLC block during the UTRAN SRVCC execution
A call is released due to the failure in the RLC block during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ RrcSigFail_Integ
count
A call is released due to receiving RRC signaling during the UTRAN SRVCC execution
A call is released due to receiving RRC signaling during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ S1apCuFail_Integ
count
A call is released due to the S1AP specification cause during the UTRAN SRVCC execution
A call is released due to the S1AP specification cause during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ S1apLinkFail_Integ
count
A call is released due to the S1 SCTP link failure during the UTRAN SRVCC execution
A call is released due to the S1 SCTP link failure during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ S1apRoTo_Integ
count
A call is released due to S1AP relocoverall timeout (not received) during the UTRAN SRVCC execution
A call is released due to S1AP relocoverall timeout (not received) during the UTRAN SRVCC execution
-
CC
event
int
0~21474 83647
-
-
UtranSrvccOutFail_ S1apSigFail_Integ
count
A call is released due to receiving S1AP signaling during the
A call is released due to receiving S1AP signaling during the
-
CC
event
int
0~21474 83647
-
-
execution
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
901
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
UTRAN SRVCC execution
UTRAN SRVCC execution
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CSL This section provides statistics on the Call Summary Log (CSL) and it counts when the call is dropped. It can be used to collect various information and actual release cause for the call for example Call Release Cause. These statistics items are described in the following tables.
Call Fail This section provides statistics on the CSL. The CSL statistics are collected when the call is released, and can help identify the actual cause of the call release. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0FFF]NoFault
count
The call is terminated normally.
Y
CC
event
int
0~2147483647
-
-
[0x0100]S1ap_Cause RadioNetworkUnspeci fied
count
During handover, the target eNB transmits the Path Switch Request message, and then does not
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
902
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
receive the Path Switch Response, but receives the UE Context Release Command message. [0x0101]S1ap_Tx2Rel ocOverallExpiry
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0102]S1ap_Succes sfulHandover
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0103]S1ap_Releas eDueToEutranGenera tedReason
count
A call is released due to redirection when MR is received from the UE.
Y
CC
event
int
0~2147483647
-
-
[0x0104]S1ap_Hando verCancelled
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0105]S1ap_Partial Handover
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0106]S1ap_HoFail ureInTargetEpcEnbOr TargetSystem
count
When a failure cause is received from target system as the Forward Relocation Response during InterMME/Inter-RAT S1 handover, it is transmitted by being specified in the Handover Preparation Failure.
Y
CC
event
int
0~2147483647
-
-
[0x0107]S1ap_HoTar getNotAllowed
count
If S1 handover fails due to AccessRestriction (such as Utran Not Allow) of the UE, it is transmitted by being specified in the Handover Preparation Failure.
Y
CC
event
int
0~2147483647
-
-
[0x0108]S1ap_TS1Re locOverallExpiry
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0109]S1ap_TS1Re locPrepExpiry
count
In S1_OUT statistics event, when the timer waiting for the handover command expires after the source eNB transmits the Handover
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
903
Chapter 2 Counter Description Name
Unit
[0x010A]S1ap_CellNo tAvailable
count
[0x010B]S1ap_Unkno wnTargetId
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
count
When it is not possible to find the TAI information for the TargetID received via the Handover Required or the remote MME information, it is transmitted by being specified in the Handover Preparation Failure.
Y
CC
event
int
0~2147483647
-
-
[0x010C]S1ap_NoRad ioResourcesAvailableI nTargetCell
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x010D]S1ap_Unkno wnMmeUES1apId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x010E]S1ap_Unkno wnEnbUES1apId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x010F]S1ap_Unkno wnPairUES1apId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0110]S1ap_Hando verDesirableForRadio Reason
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0111]S1ap_TimeCr iticalHandover
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0112]S1ap_Resour ceOptimizationHando ver
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0113]S1ap_Reduc eLoadInServingCell
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0114]S1ap_UserIn
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
Required message.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
904
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0115]S1ap_Radio ConnectionWithUELo st
count
At the time of DownlinkNASTransport message transmission, if MaxRetransInd or OutOfSync happens, eNB sends NAS Non Delivery message with S1 cause of 'radio_connection_with_ue_lost' to MME. And, if MME replies UE Context Release Command with same S1 cause, eNB generates the counter.
Y
CC
event
int
0~2147483647
-
-
[0x0116]S1ap_LoadB alancingTauRequired
count
When the RLB value of MME-INF is changed to other value than NONE, it is transmitted by being specified in the UE context release command for MME re-load balancing.
Y
CC
event
int
0~2147483647
-
-
[0x0117]S1ap_CsFall backTriggered
count
A call is released due to CSFB that causes the inter-RAT redirection.
Y
CC
event
int
0~2147483647
-
-
[0x0118]S1ap_UENot AvailableForPsServic e
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0119]S1ap_Radio ResourcesNotAvailabl e
count
A call is released due to resource allocation failure in eNB for the bearer where setup is requested by the MME.
Y
CC
event
int
0~2147483647
-
-
[0x011A]S1ap_Failure InRadioInterfaceProce dure
count
If during RRE procedure eNB transmits UE Context Release Request message with the S1 cause of 'ci_s1ap_failure_in_radio_interface
Y
CC
event
int
0~2147483647
-
-
activity
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
905
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
_procedure" to MME and MME sends UE Context Release Command message with same S1 cause, eNB generate the counter. [0x011B]S1ap_Invalid QosCombination
count
When gbrType of QCI received within E_RABLevelQoSParameters IE of the Initial Context Setup Request message is GBR but the gbrQosInformation received is the ‘not present’ message When gbrType of QCI received within E_RABLevelQoSParameters IE of the E_RAB Setup Request message is GBR but the gbrQosInformation received is the ‘not present’ message When gbrType of QCI received within E_RABLevelQoSParameters IE of the E_RAB Modify Request message is GBR but the gbrQosInformation received is the ‘not present’ message
Y
CC
event
int
0~2147483647
-
-
[0x011C]S1ap_InterR atRedirection
count
A call is released due to the interRAT redirection. It occurs when redirection is processed normally due to the inter-RAT redirection.
Y
CC
event
int
0~2147483647
-
-
[0x011D]S1ap_Interac tionWithOtherProcedu re
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
906
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x011E]S1ap_Unkno wnErabId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x011F]S1ap_Multipl eErabIdInstances
count
A call is released due to receiving the information with the same ERAB ID after the Initial Context Setup Request message is received.
Y
CC
event
int
0~2147483647
-
-
[0x0120]S1ap_Encryp tionAndOrIntegrityProt ectionAlgorithmsNotS upported
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0121]S1ap_S1Intra SystemHandoverTrigg ered
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0122]S1ap_S1Inter SystemHandoverTrigg ered
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0123]S1ap_X2Han doverTriggered
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0124]S1ap_Redire ctionTowards1xRtt
count
A call is released due to redirection to 1xRTT.
Y
CC
event
int
0~2147483647
-
-
[0x0125]S1ap_NotSu pportedQciValue
count
A call is released due to receiving the QCI value not supported by eNB through the Initial Context Setup Request message.
Y
CC
event
int
0~2147483647
-
-
[0x0126]S1ap_Invalid CsgId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0128]S1ap_Transp ortResourceUnavailab le
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
907
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0129]S1ap_Cause TransportUnspecified
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0132]S1ap_Normal Release
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0133]S1ap_Authen ticationFailure
count
MME transmits the UE Context Release Command message including the cause value due to the UE authentication failure during the attach.
Y
CC
event
int
0~2147483647
-
-
[0x0134]S1ap_Detach
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0135]S1ap_Cause NasUnspecified
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0136]S1ap_CsgSu bscriptionExpiry
count
If S1 is released because the UE whose location was registered in the CSG area has no or expired CSG subscription, the UE Context Release command is transmitted. The CSG-related causes will be supported later.
Y
CC
event
int
0~2147483647
-
-
[0x013C]S1ap_Transf erSyntaxError
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x013D]S1ap_Abstra ctSyntaxErrorReject
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x013E]S1ap_Abstra ctSyntaxErrorIgnoreA ndNotify
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x013F]S1ap_Messa geNotCompatibleWith ReceiverState
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0140]S1ap_Seman
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
908
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0141]S1ap_Abstra ctSyntaxErrorFalselyC onstructedMessage
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0142]S1ap_Cause ProtocolUnspecified
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0146]S1ap_Control ProcessingOverload
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0147]S1ap_NotEn oughUserPlaneProces singResources
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0148]S1ap_Hardw areFailure
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0149]S1ap_OmInte rvention
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x014A]S1ap_Cause MiscUnspecified
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x014B]S1ap_Unkno wnPlmn
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0200]X2ap_Hando verDesirableForRadio Reasons
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0201]X2ap_TimeCr iticalHandover
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0202]X2ap_Resour ceOptimizationHando ver
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0203]X2ap_Reduc eLoadInServingCell
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
ticError
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
909
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0204]X2ap_Partial Handover
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0205]X2ap_Unkno wnNewEnbUEX2apId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0206]X2ap_Unkno wnOldEnbUEX2apId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0207]X2ap_Unkno wnPairOfUEX2apId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0208]X2ap_HoTar getNotAllowed
count
If the DRB CAC procedure fails in the target during X2 handover, this will be included in the X2_IN and X2_OUT preparation fail statistics.
Y
CC
event
int
0~2147483647
-
-
[0x0209]X2ap_Tx2Rel ocOverallExpiry
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x020A]X2ap_Treloc prepExpiry
count
If the Handover Request Acknowledge message is not received from the target eNB during X2 handover, this will be included in the X2_OUT preparation fail statistics of the source eNB.
Y
CC
event
int
0~2147483647
-
-
[0x020B]X2ap_CellNo tAvailable
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x020C]X2ap_NoRad ioResourcesAvailableI nTargetCell
count
If the cell information corresponding to the target ID transmitted via the handover request message is not found in the target eNB, this will be included in the X2_IN and X2_OUT preparation fail statistics.
Y
CC
event
int
0~2147483647
-
-
[0x020D]X2ap_Invalid
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
910
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x020E]X2ap_Unkno wnMmeCode
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x020F]X2ap_Encryp tionAndOrIntegrityProt ectionAlgorithmsNotS upported
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0210]X2ap_Report CharacteristicsEmpty
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0211]X2ap_NoRep ortPeriodicity
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0212]X2ap_Existin gMeasurementId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0213]X2ap_Unkno wnEnbMeasurementId
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0214]X2ap_Measu rementTemporarilyNot Available
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0215]X2ap_Cause RadioNetworkUnspeci fied
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0216]X2ap_LoadB alancing
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0217]X2ap_Hando verOptimization
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0218]X2ap_Value OutOfAllowedRange
count
A call is released when the QCI value of the E-RAB level QoS parameters is out of the range specified in the specification during bearer setup in the target eNB.
Y
CC
event
int
0~2147483647
-
-
MmeGroupId
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
911
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This will be included in the X2_IN and X2_OUT preparation fail statistics. [0x0219]X2ap_Multipl eErabIdInstances
count
A call is released when setup is requested for the same ERAB ID during bearer setup in the target eNB. This will be included in the X2_IN and X2_OUT preparation fail statistics.
Y
CC
event
int
0~2147483647
-
-
[0x021A]X2ap_Switch OffOngoing
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x021E]X2ap_Transp ortResourceUnavailab le
count
A call is released when the internal resource setup fails in the target eNB during X2 handover; this will be included in the X2 IN Preparation Fail cause.
Y
CC
event
int
0~2147483647
-
-
[0x021F]X2ap_Cause TransportUnspecified
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0228]X2ap_Transf erSyntaxError
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0229]X2ap_Abstra ctSyntaxErrorReject
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x022A]X2ap_Abstra ctSyntaxErrorIgnoreA ndNotify
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x022B]X2ap_Messa geNotCompatibleWith ReceiverState
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x022C]X2ap_Sema nticError
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x022D]X2ap_Cause
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
912
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x022E]X2ap_Abstra ctSyntaxErrorFalselyC onstructedMessage
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0232]X2ap_Control ProcessingOverload
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0233]X2ap_Hardw areFailure
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0234]X2ap_OmInte rvention
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0235]X2ap_NotEn oughUserPlaneProces singResources
count
Currently not in use.
Y
CC
event
int
0~2147483647
-
-
[0x0236]X2ap_Cause MiscUnspecified
count
The Handover Cancel message is transmitted to the target eNB due to reestablishment to the source eNB during X2 handover. This call release will be included the X2_IN Fail statistics.
Y
CC
event
int
0~2147483647
-
-
[0x0300]EccTmout_Rr cConnectionSetupCo mplete
count
A call is released when the RRC Connection Setup Complete message is not received after the RRC Connection Setup message is transmitted to the UE.
Y
CC
event
int
0~2147483647
-
-
[0x0301]EccTmout_Rr cConnectionReconfig Complete
count
A call is released when the RRC Connection Reconfiguration Complete message is not received after transmitting the RRC Connection Reconfiguration message.
Y
CC
event
int
0~2147483647
-
-
[0x0302]EccTmout_Rr
count
A call is released when the RRC
Y
CC
event
int
0~2147483647
-
-
ProtocolUnspecified
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
913
Chapter 2 Counter Description Name
Unit
cConnectionReestabli shComplete
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Connection Reestablishment Complete message is not received from the UE after transmitting the RRC Connection Reestablishment message to the UE.
[0x0303]EccTmout_Rr cSecurityModeCompl ete
count
A call is released when the Security Mode Complete message is not received after the Security Mode Command message is transmitted to the UE.
Y
CC
event
int
0~2147483647
-
-
[0x0304]EccTmout_Rr cUECapabilityInformat ion
count
A call is released when the UE Capability Information message is not received after the UE Capability Enquiry message is transmitted to the UE.
Y
CC
event
int
0~2147483647
-
-
[0x0306]EccTmout_Rr cHandoverPreparation
count
A call is released when the UL Handover Preparation Transfer message is not received after transmitting the Handover From EUTRA Preparation Request during the Inter RAT HRPD handover. Not applicable to the service provider who does not use the HRPD handover.
Y
CC
event
int
0~2147483647
-
-
[0x0307]EccTmout_Int raHandoverCmdComp lete
count
A call is released when the target cell cannot receive the RRC Connection Reconfiguration Complete message during the intra-handover.
Y
CC
event
int
0~2147483647
-
-
[0x0308]EccTmout_Int erX2HandoverCmdCo mplete
count
A call is released when the target eNB cannot receive the RRC Connection Reconfiguration
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
914
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Complete message during the X2 handover. [0x0309]EccTmout_Int erS1HandoverCmdCo mplete
count
A call is released when the target eNB cannot receive the RRC Connection Reconfiguration Complete message during the S1 handover.
Y
CC
event
int
0~2147483647
-
-
[0x0313]EccTmout_S 1InitialContextSetupR equest
count
A call is released when the Initial Context Setup Request message is not received after transmitting the Initial UE message to the MME.
Y
CC
event
int
0~2147483647
-
-
[0x0316]EccTmout_S 1PathSwitchAck
count
A call is released when the Path Switch Request Acknowledge message is not received after the target eNB transmits the Path Switch Request message during the X2 handover.
Y
CC
event
int
0~2147483647
-
-
[0x0317]EccTmout_S 1HandoverPreparatio n
count
A call is released when DownlinkS1 cdma2000tunneling message is not received after transmitting the UplinkS1cdma 2000tunneling message to MME during the Inter RAT HRPD handover. Not applicable to the service provider who does not use the HRPD handover.
Y
CC
event
int
0~2147483647
-
-
[0x0318]EccTmout_S 1RelocOverall
count
A call is released when a RelocOverall Timeout occurs in the source eNB during the S1 handover.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
915
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x031A]EccTmout_S 1MmeStatusTransfer
count
A call is released when the target eNB cannot receive the MME Status Transfer message after the source eNB transmits the eNB Status Transfer message to the MME.
Y
CC
event
int
0~2147483647
-
-
[0x0324]EccTmout_X 2RelocOverall
count
A call is released when a RelocOverall Timeout occurs in the source eNB during the X2 handover.
Y
CC
event
int
0~2147483647
-
-
[0x0325]EccTmout_X 2SnStatusTransfer
count
A call is released when the target eNB cannot receive the X2 SN Status Transfer message transmitted from the source eNB.
Y
CC
event
int
0~2147483647
-
-
[0x0330]EccTmout_Int ernalResourceSetup
count
A response message is not received after the SetupReq message is transmitted to allocate resources to the protocol blocks within the eNB.
Y
CC
event
int
0~2147483647
-
-
[0x0332]EccTmout_Int ernalSecurityControl
count
A call is released when a response is not received from the PDCB block while transferring the security information to eNB’s internal PDCB block during attach procedure.
Y
CC
event
int
0~2147483647
-
-
[0x0334]EccTmout_Int ernalForwardingPathS etup
count
A call is released when no response is received for the request of uplink and downlink path setup between the ECCB block and the eNB’s internal block GTPB during handover.
Y
CC
event
int
0~2147483647
-
-
[0x0335]EccTmout_Int ernalReestablishContr
count
A call is released when no response message is received
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
916
Chapter 2 Counter Description Name
Unit
ol
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
from RLCB and PDCB blocks while configuring the eNB’s ECCB block and internal RLCB and PDCB blocks for RLC and PDCP Reestablishment during X2/S1 handover.
[0x0336]EccTmout_Int ernalBufferFlush
count
A call is released when no response message is received from the PDCB while interfacing between the ECCB and PDCB for buffer flush during handover.
Y
CC
event
int
0~2147483647
-
-
[0x0337]EccTmout_Int ernalDataTransferStar t
count
A call is released when PDCP setup fails in the target eNB during handover.
Y
CC
event
int
0~2147483647
-
-
[0x0341]Ecc_UserIna ctivity
count
A call is released due to no traffic transmission during the given period of time (user inactivity time) for a specific UE when the MACB block detects the user inactivity, and notifies the fact to the ECCB block.
Y
CC
event
int
0~2147483647
-
-
[0x0342]Ecc_ArqMax ReTransmission
count
A call is released when the RLCB block made transmission to the UE as many times as the Max Retransmission, but ARQ ACK is not received from the UE, which is notified to the ECCB.
Y
CC
event
int
0~2147483647
-
-
[0x0343]Ecc_RadioLin kFailure
count
When the MACB determines the Sync disconnection with the UE, it notifies the ECCB of OutOfSync. If the ECCB is notified of the MACB of being InSync again (HARQ-ACK/NACK received 20
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
917
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
times), or if it fails to receive the RRC Connection Reestablishment Request from the UE, the call is released after a timeout (default: 5 seconds). [0x0344]Ecc_UECont extNotFound
count
Although the UE requested the Reestablishment, cannot perform Reestablishment because could not find the UE Context information in eNB.
Y
CC
event
int
0~2147483647
-
-
[0x0345]Ecc_S1ApSn StatusNotReceived
count
If the RRC Connection Reestablishment Request message is received while waiting for the SN Status Transfer message from the source eNB or the MME Status Transfer message from the MME, the RRC Connection Reestablishment Reject message is transmitted to the UE.
Y
CC
event
int
0~2147483647
-
-
[0x0346]Ecc_ReestFa ilInvalidState
count
If the RRC Connection Reestablishment Request message is received during Attach, the eNB detects that reestablishment occurs while the DRB setup is not normal, and releases the call.
Y
CC
event
int
0~2147483647
-
-
[0x0347]Ecc_CdmaHa ndoverPreparationFail ure
count
A call is released when the UL Handover Preparation Transfer message is not received after transmitting the Handover From EUTRA Preparation Request during the Inter RAT HRPD
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
918
Chapter 2 Counter Description Name
Unit
[0x0348]Ecc_RcvS1U ECtxtReleaseCmdAbn ormalState
count
[0x0349]Ecc_RcvRes etRequestFromEcmb
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
A call is released when the UE Context Release Command message is received when the UE Associated setup is not made with the MME. If this cause occurs, it is necessary to check the cause value delivered to the MME.
Y
CC
event
int
0~2147483647
-
-
count
A call is released due to receiving a reset request from ECMB due to refork of a specific block in eNB.
Y
CC
event
int
0~2147483647
-
-
[0x034A]Ecc_RcvS1R esetFromMme
count
The call in the handover process is released by receiving a reset message from the MME.
Y
CC
event
int
0~2147483647
-
-
[0x034B]Ecc_RcvX2R esetRequest
count
A call is released due to the reception of the Reset Request message from other eNB.
Y
CC
event
int
0~2147483647
-
-
[0x034C]Ecc_S1Sctp OutOfService
count
A call is released when the S1 Association’s status is changed from In Service to Out of Service state.
Y
CC
event
int
0~2147483647
-
-
[0x034D]Ecc_RcvCell ReleaseIndFromEcmb
count
A call is released due to the Cell Release Ind message received from the ECMB block because of DSP down or CPRI failure caused by DSP problem. (CPRI deleted)
Y
CC
event
int
0~2147483647
-
-
[0x034E]Ecc_DspAudi tRlcCallRelease
count
A call is released when the call remains in the ECCB and MACB, but not in the RLCB, which causes resource mismatch.
Y
CC
event
int
0~2147483647
-
-
handover.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
919
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x034F]Ecc_DspAudi tMacCallRelease
count
A call is released when the call remains in the ECCB and RLC, but not in the MACB, which causes resource mismatch.
Y
CC
event
int
0~2147483647
-
-
[0x0350]Ecc_DspAudi tRlcMacCallRelease
count
A call is released when the call remains in the ECCB, but not in the RLC and MAC, which causes resource mismatch.
Y
CC
event
int
0~2147483647
-
-
[0x0351]Ecc_SecAlgo rithmsCombinationInv alid
count
The security algorithm value is received in the Initial Context Setup Request, S1 Handover Request, X2 Handover Request, S1 UE Context Modification message. A call is released when the ciphering algorithm does not have the null algorithm value if the integrity algorithm supports the null algorithm.
Y
CC
event
int
0~2147483647
-
-
[0x0352]Ecc_X2Sctp OutOfService
count
A call is released when the X2 Association’s status is changed from In Service to Out of Service state.
Y
CC
event
int
0~2147483647
-
-
[0x0353]Ecc_Release DueToEnbGenerated Reason
count
A call is released due to the internal cause in eNB.
Y
CC
event
int
0~2147483647
-
-
[0x0354]Ecc_InterFaR edirection
count
When processing the redirection to the inter FA (If it conflicts with the CRR output conditions based on the S1AP cause, the CRR in the column D (Call Release Cause) is displayed.)
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
920
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0355]Ecc_CSFBCo nfigFailure
count
A call is released when, even if CSFB was triggered by the InitialContextSetupRequest message, the CSFB redirection cannot be processed due to eNB setting error (Inter RAT FA information not specified).
Y
CC
event
int
0~2147483647
-
-
[0x0365]Rrm_Fail
count
The DB initialization procedure managed by the ERRM fails.
Y
CC
event
int
0~2147483647
-
-
[0x0366]Rrm_CellBarr ed
count
A call is released when RRC Connection Reject message is transmitted due to call rejection because the relevant cell is barred even when the RRC Connection Request message is received.
Y
CC
event
int
0~2147483647
-
-
[0x0367]Rrm_MaxCall CountOver
count
When calls are generated exceeding the number of calls that can be accommodated, they are rejected by CAC.
Y
CC
event
int
0~2147483647
-
-
[0x0368]Rrm_MaxDrb CountOver
count
When calls are generated exceeding the number of DRB that can be accommodated by cell, they are rejected by CAC.
Y
CC
event
int
0~2147483647
-
-
[0x0369]Rrm_QosCac Fail
count
The call with the QoS that cannot be allowed by the cell is generated; it is rejected by CAC.
Y
CC
event
int
0~2147483647
-
-
[0x036A]Rrm_Preemp tionFail
count
Preemption fails because the requested ERAB’s priority is under the priority of the existing UE.
Y
CC
event
int
0~2147483647
-
-
[0x036B]Rrm_CallRsc Fail
count
Call ID is all assigned thus Call ID cannot be assigned any more.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
921
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x036C]Rrm_BhCac Fail
count
A call is released when the BH link usage by a specific QoS (GBR Bearer) exceeds the threshold defined in the PLD.
Y
CC
event
int
0~2147483647
-
-
[0x036D]Rrm_SrsRsc Fail
count
When a new call supports both SRS and DRX, the SRS resources need to assigned in advance to assign the DRX resources but the DRX resources cannot be assigned because the SRS resource is not assigned.
Y
CC
event
int
0~2147483647
-
-
[0x036E]Rrm_CqiRsc Fail
count
CQI/PMI resources are all assigned thus cannot assign the resource any more.
Y
CC
event
int
0~2147483647
-
-
[0x036F]Rrm_SpsRsc Fail
count
SPS resources are all assigned thus the SPS resource cannot be assigned any more.
Y
CC
event
int
0~2147483647
-
-
[0x0370]Rrm_N1Pucc hRscFail
count
n1PucchAnRep resources are all assigned thus the resource cannot be assigned any more.
Y
CC
event
int
0~2147483647
-
-
[0x0371]Rrm_SrRscF ail
count
During SR resource allocation and release, the SR resource search is not allowed to exceed the Max value of the SR resource DB.
Y
CC
event
int
0~2147483647
-
-
[0x0372]Rrm_TpcRsc Fail
count
During TPC PUCCH RNTI resource allocation and release, the TPC PUCCH resource search is not allowed to exceed the Max value of TPC PUCCH resource DB.
Y
CC
event
int
0~2147483647
-
-
[0x0373]Rrm_AllMme NotService
count
A call is rejected because there exists no MME currently in
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
922
Chapter 2 Counter Description Name
Unit
[0x0374]Rrm_MmeOv erload
count
[0x0375]Rrm_NotExist Mme
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
When the MME is in Overload status, cannot accommodate the calls because overloadAction and establishmentCause does not match.
Y
CC
event
int
0~2147483647
-
-
count
The registered MME information that the UE informs in the RRC Connection Setup Complete message does not exist in the eNB database.
Y
CC
event
int
0~2147483647
-
-
[0x0376]Rrm_Availabl eMmeNotExist
count
The MME with the PLMN value informed by the UE does not exist in the RRC Connection Setup Complete message.
Y
CC
event
int
0~2147483647
-
-
[0x0377]Rrm_UEStms iDuplicate
count
The same UE transmits the RRC Connection Request with the same S-TMSI value.
Y
CC
event
int
0~2147483647
-
-
[0x0600]Gtp_SetupFai l
count
A call is released when a response to GTP Setup Fail is transmitted after the SetupReq message is received from the ECCB. Tunnel information error managed by the GTPB block and tunnel setting failure due to DB management error are notified to the ECCB.
Y
CC
event
int
0~2147483647
-
-
[0x0601]Gtp_Release Fail
count
An error response is generated when GTP Release fails.
Y
CC
event
int
0~2147483647
-
-
[0x0602]Gtp_ModifyF ail
count
A call is released when a response to GTP Modify Fail is transmitted after the ModifyReq message is
Y
CC
event
int
0~2147483647
-
-
connection.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
923
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
received from the ECCB. Tunnel information error managed by the GTPB block and tunnel setting failure due to DB management error are notified to the ECCB. [0x0603]Gtp_ResetFai l
count
A call is released if there is response for Gtp setup fail after receiving the ModifyReq message from the ECMB.
Y
CC
event
int
0~2147483647
-
-
[0x0604]Gtp_PathFail
count
If there is no Echo Response within 60 seconds after Echo Request is transmitted periodically to the peer node of the EPS bearer, the request is retransmitted five times at the interval of 5 seconds. If there is still no response, ECCB receives the response indicating a path to the peer node is abnormal. The GTPB block determines that a bearer path to the peer node is abnormal or GTP entity within the peer node is abnormal and notifies the ECCB block of the failure.
Y
CC
event
int
0~2147483647
-
-
[0x0605]Gtp_NotSupp ortEh
count
Send a response when receiving the message with the extension header that cannot be supported by the system from dst peer during tunnel setup.
Y
CC
event
int
0~2147483647
-
-
[0x0606]Gtp_RcvError IndFromGw
count
A bearer is released when an error indication message is received from the peer node of GTPB,
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
924
Chapter 2 Counter Description Name
Unit
[0x0700]Pdcp_Invalid CallId
count
[0x0701]Pdcp_Invalid RbId
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
An error response is generated when the callid of the downloaded message from the ECCB is the value of the MAX_USER_ENB or higher.
Y
CC
event
int
0~2147483647
-
-
count
When Rbid of the message received from ECCB is MAX_RB or less for PDCP_DRB and MAX_SRB or less for PDCP_SRB, the message is normal. Otherwise, an error response is generated. There is no possibility that it will a CSL cause.
Y
CC
event
int
0~2147483647
-
-
[0x0702]Pdcp_Invalid NumOfRb
count
An error response is generated when the NumRb of the downloaded message from the ECCB is the value of the CI_MAX_RB or higher.
Y
CC
event
int
0~2147483647
-
-
[0x0703]Pdcp_Invalid RlcMode
count
An error response is generated when the RLC mode of the message downloaded from the ECCB is invalid.
Y
CC
event
int
0~2147483647
-
-
[0x0704]Pdcp_Invalid SetupType
count
An error response is generated when the setupType of the message downloaded from the ECCB is invalid.
Y
CC
event
int
0~2147483647
-
-
[0x0705]Pdcp_Invalid CntlType
count
An error response is generated when the CntlType of the message downloaded from the ECCB is invalid.
Y
CC
event
int
0~2147483647
-
-
[0x0706]Pdcp_Invalid
count
An error response is generated
Y
CC
event
int
0~2147483647
-
-
which is notified to the ECCB.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
925
Chapter 2 Counter Description Name
Unit
PdcpSnType
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
when the SNType of the message downloaded from the ECCB is UM, but not 7-bit or 12-bit.
[0x0707]Pdcp_Invalid LochType
count
An error response is generated when the logical type of the message downloaded from the ECCB is other than either LOCH_DCCH (for the SRB) or LOCH_DTCH (for the DRB). There is no possibility that it will a CSL cause.
Y
CC
event
int
0~2147483647
-
-
[0x0708]Pdcp_RohcS etupFail
count
An error response is generated when the ROHC context setup procedure fails due to lack of memory while receiving ConfigReq from the ECCB.
Y
CC
event
int
0~2147483647
-
-
[0x0709]Pdcp_Inactiv ateRbId
count
A call is released when the message on Inactive RB is received while receiving the msgCpdcpModifyReq from the ECCB.
Y
CC
event
int
0~2147483647
-
-
[0x070A]Pdcp_SrbInte grityFail
count
A call is released when SRB’s integrity check failure notification is received from the PDCB.
Y
CC
event
int
0~2147483647
-
-
[0x0846]Rlc_InvalidPa rameter
count
An error response is generated when the parameter of the message received from the ECCB is not the value within the defined range.
Y
CC
event
int
0~2147483647
-
-
[0x0847]Rlc_NoMore Resource
count
An error response is generated when a new connection cannot be allowed due to insufficient
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
926
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
resources to be allocated to the message received from the ECCB. [0x0848]Rlc_CellIsIdle
count
An error response is generated when cell ID status of the message received from the ECCB is IDLE, not ACTIVE.
Y
CC
event
int
0~2147483647
-
-
[0x0849]Rlc_CallIsNot Active
count
An error response is generated when the call ID status of the message received from the ECCB is not ACTIVE.
Y
CC
event
int
0~2147483647
-
-
[0x0880]Rlc_ErrorEm ptyMsg
count
An error response is generated when the message received by the RLC is NULL.
Y
CC
event
int
0~2147483647
-
-
[0x0881]Rlc_ErrorUnk nownMsgId
count
An error response is generated when the type of the message received by the RLC is unknown
Y
CC
event
int
0~2147483647
-
-
[0x0882]Rlc_ErrorInva lidDataLen
count
An error response is generated when the size of the message received by the RLC is abnormal.
Y
CC
event
int
0~2147483647
-
-
[0x0883]Rlc_ErrorNo RspFromDL
count
An error response is generated when the RLC downlink does not respond to the message received.
Y
CC
event
int
0~2147483647
-
-
[0x0884]Rlc_ErrorNo RspFromUL
count
An error response is generated when the RLC uplink does not respond to the message received.
Y
CC
event
int
0~2147483647
-
-
[0x0885]Rlc_ErrorNo RspFromDLUL
count
An error response is generated when the RLC downlink and uplink do not respond to the message received.
Y
CC
event
int
0~2147483647
-
-
[0x0886]Rlc_ErrorRxB eforeRlcReady
count
An error response is generated when the RLC uplink receives a
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
927
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
signaling message before it operates properly. [0x0887]Rlc_ErrorInva lidRlcTransactionId
count
An error response is generated when the transaction ID exceeds the specified range while the RLC processes the message received from the ECCB.
Y
CC
event
int
0~2147483647
-
-
[0x0888]Rlc_ErrorInva lidContext
count
An error response is generated when a response is retransmitted from the RLC downlink for the signaling message that the RLC has already processed.
Y
CC
event
int
0~2147483647
-
-
[0x0889]Rlc_ErrorRlc ContextFull
count
An error code is generated when the number of the signaling messages received exceeds the capacity that the RLC can process.
Y
CC
event
int
0~2147483647
-
-
[0x0900]Mac_InvalidM sgId
count
An undefined Message Id is received.
Y
CC
event
int
0~2147483647
-
-
[0x0901]Mac_InvalidS etupType
count
An undefined SetupType is received.
Y
CC
event
int
0~2147483647
-
-
[0x0902]Mac_InvalidC allCellId
count
When the ‘cell call ID’ value of the message received from the ECCB is outside the defined range.
Y
CC
event
int
0~2147483647
-
-
[0x0903]Mac_InvalidP arameter
count
When the parameter received is outside the defined range.
Y
CC
event
int
0~2147483647
-
-
[0x0904]Mac_Insuffici entResource
count
The RB cannot be allocated due to insufficient MACB internal resource required to manage the RB.
Y
CC
event
int
0~2147483647
-
-
[0x0905]Mac_NotAssi gnedRb
count
A reconfig/delete request is received for the RB that is not allocated.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
928
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
[0x0906]Mac_NotAssi gnedUE
count
A config/delete request is received for the UE that is not allocated.
Y
CC
event
int
0~2147483647
-
-
[0x0908]Mac_NotAssi gnSrb1
count
When the call setup message is received without SRB1 setup.
Y
CC
event
int
0~2147483647
-
-
[0x0909]Mac_InvalidR bConfig
count
When the RB number within the Logical Channel Config exceeds the maximum value.
Y
CC
event
int
0~2147483647
-
-
[0x090A]Mac_InvalidC ellId
count
When the cell that corresponds to the received message is idle.
Y
CC
event
int
0~2147483647
-
-
[0x0357]EccTmout_s CellAdditionFailure
count
A call is released when RRC Connection Reconfiguration Complete message is not received from UE, after RRC Connection Reconfiguration message is transmitted to UE for SCell Addition.
Y
CC
event
int
0~2147483647
-
-
[0x0358]EccTmout_s CellReleaseFailure
count
A call is released when RRC Connection Reconfiguration Complete message is not received from UE, after a RRC Connection Reconfiguration message is transmitted to UE for SCell Release.
Y
CC
event
int
0~2147483647
-
-
[0x0359]Ecc_RcvGtp AliveInd
count
Restart GTP in Inter DU
Y
CC
event
int
0~2147483647
-
-
[0x035A]Ecc_RcvSeR estart
count
Restart SE in Inter DU
Y
CC
event
int
0~2147483647
-
-
[0x0378]Rrm_LbhoCa cFailure
count
when receiving the handover request for the purpose of load balancing, it adds up if the cell load exceeds the target cell load
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
929
Chapter 2 Counter Description Name
Unit
[0x035C]Rrm_Overloa dProtection
count
[0x035D]Ecc_RadioLi nkFailurebyRRE
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
A call is rejected by Overload Protection control function
Y
CC
event
int
0-2147483647
-
-
count
The MACB determines that sync with the UE has been disconnected, which notifies the ECCB of OutOfSync. This failure occurs when the ECCB is notified of InSync by the MACB (receiving HARQ-ACK/NACK 20 times) or when a conflict with the CRR833 (C_ECCB_USER_INACTIVITY) output condition is occurred while receiving an RRC Connection Reestablishment Request message on standby.
Y
CC
event
int
0~2147483647
-
-
[0x0379]Rrm_Preemp tionFailCpFail
count
When RRC establishment has failed due to a preemption failure (when an InitialContextSetupFailure message has been transmitted)
Y
CC
event
int
0~2147483647
-
-
[0x070B]Pdcp_Invalid cellNum
count
When the cellNum of the message received from the ECCB has an inappropriate value, it reports that it has received a wrong message (when a conflict with the S1APcause-based CCR output conditions occurs)
Y
CC
event
int
0~2147483647
-
-
[0x35F]Ecc_ARQMax RetransmissionbyRR E
count
When ARQ ACK cannot be received from the UE, even though the RLC layer made transmission as many times as the max retransmission count. When a
Y
CC
event
int
0~2147483647
-
-
threshold
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
930
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
conflict with the RR833 (C_ECCB_USER_INACTIVITY) output conditions occurs after RLF detection in the MAC layer, an RRC Connection Re-establishment Request message could not be received from the UE.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
931
Chapter 2 Counter Description
MRO This section provide statistics on the Mobility Robustness Optimization (MRO) that are intended to collect and classify handover issues due to Radio Link Failure (RLF) occurring during or after a handover, and use them in the MRO algorithm to optimize handover parameters (e.g. Cell Individual Offset) and improve the handover performance.
MRO RLF Classification This section provides statistics on the MRO RLF Classification. The causes of the handover-related RLF recorded as MRO issues are: toolate handover, too-early handover, and handover to a wrong cell. The causes of the RLF not recorded as MRO issues are recorded as coverage holes. Index Name
Description
cNum
Cell number to detect Handover problem
NeighborCell
Neighbor Cell Identity that is the subject of Handover problem
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CoverageHole
count
Number of RLF/HO failures due to the coverage hole
Y
CC
event
int
0~2147483647
-
-
CoverageHoleN
count
Number of RLF/HO failures due to the coverage hole toward Cell N
Y
CC
event
int
0~2147483647
-
-
TooEarlyHoFailur e
count
The number of too-early handovers after transmitting the handover
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
932
Chapter 2 Counter Description Name
Unit
TooEarlyHoRlfAft erHo
count
TooLateHoRlfBef oreTriggering
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The number of too-early handovers after completing the handover process.
Y
CC
event
int
0~2147483647
-
-
count
The number of RLFs before triggering the handover.
Y
CC
event
int
0~2147483647
-
-
TooLateHoRlfAfte rTriggering
count
The number of RLFs after the handover command is transmitted.
Y
CC
event
int
0~2147483647
-
-
WrongCellRlfAfter Triggering
count
The number of handovers to a wrong cell before transmitting the handover command.
Y
CC
event
int
0~2147483647
-
-
WrongCellRlfAfter Ho
count
The number of handovers to a wrong cell after transmitting the handover command.
Y
CC
event
int
0~2147483647
-
-
BlackCellRlfAfter Ho
count
The number of handovers to a black cell RLF after HO (X2)
-
CC
event
int
0~2147483647
-
-
PingpongHandov er
count
The number of ping-pong handovers detected by the ping-pong detection algorithm.
Y
CC
event
int
0~2147483647
-
-
MroRlfCnt
count
MRO RLF Classification collection count
-
CC
event
int
0~2147483647
-
-
MroRlfCid
Neighbor Cell ID
NeighborCell ID of which collection is requested
-
OW
event
int
0~2147483647
-
-
command
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
933
Chapter 2 Counter Description
MRO RLF at RRC Connection This section provides statistics on MRO for RLF information received at the step of RRC connection setup after failure in RRC reestablishment Index Name
Description
cNum
Cell number in a base station detecting a handover problem
NeighborCell
Identifier of a neighboring cell which is a subject of handover problem (Cell Identity)
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CoverageHoleAtSetup
count
Occurrence in radio link failure by a coverage hole in a serving cell RRC reestablishment in the serving cell
Y
CC
event
int
0~21474836 47
-
-
CoverageHoleAtSetup N
count
RRC reestablishment in the target cell during or after handover
Y
CC
event
int
0~21474836 47
-
-
TooEarlyHoFailureAtS etup
count
RRC reestablishment in the source cell without the terminal moving to the target cell due to the attempt for too-early handover
Y
CC
event
int
0~21474836 47
-
-
TooEarlyHoRlfAfterH OAtSetup
count
Occurrence in radio link failure after the terminal moves to the target cell due to the attempt for too-early handover RRC reestablishment in the source cell
Y
CC
event
int
0~21474836 47
-
-
TooLateHoRlfBeforeT riggeringAtSetup
count
Occurrence in radio link failure in the serving cell by failing to attempt
Y
CC
event
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
934
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
the handover even though the terminal has moved to another cell RRC reestablishment in the serving cell HoToWrongCellRlfAft erTriggeringAtSetup
count
RRC reestablishment by the terminal in other cell while the handover procedure is not complete by attempting at the handover to the cell where the terminal is not located
Y
CC
event
int
0~21474836 47
-
-
HoToWrongCellRlfAft erHOAtSetup
count
Occurrence in radio link failure in the target cell after completion of handover by attempting at the handover to the target cell RRC reestablishment in other cell by the terminal
Y
CC
event
int
0~21474836 47
-
-
MroRrcConnCnt
count
MRO RRC connection collection count
-
CC
event
int
0~21474836 47
-
-
MroRrcConnCid
Neighbo rCell ID
NeighborCell ID requested for collection
-
OW
event
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
935
Chapter 2 Counter Description
UTRAN MRO This section provides statistics on the Inter RAT UTRAN MRO function. Index Name
Description
cNum
Cell number in a base station detecting a handover problem
UtranNbrCell
Identifier of a neighboring cell which is a subject of handover problem (Cell Identity)
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UtranTooEarlyHo
count
Too-early PS handover count to the UTRAN network
Y
CC
event
int
0~2147483647
-
-
UtranMroCnt
count
Count of UTRAN MRO collection
-
CC
event
int
0~2147483647
-
-
UtranMroCid
NeighborC ell ID
NeighborCell ID requested for collection
-
OW
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
936
Chapter 2 Counter Description
eICIC eICIC This section provides statistics on the basic operations of eICIC. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PartnershipCount
count
The average count of Partner Cell in Partnership
Y
SI
10 s
float
0~3.4*10^38
PartnershipCou ntTot/Partnershi pCountCnt
sum(Partnership CountTot)/sum(P artnershipCountC nt)
PartnershipCountT ot
count
Sum of PartnershipCount collected
-
SI
10 s
float
0~3.4*10^38
-
-
PartnershipCountC nt
count
Count of PartnershipCount collected
-
SI
10 s
int
0~2147483647
-
-
EICICCapaUECou nt
count
Number of UEs that support FGI bit 115
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
937
Chapter 2 Counter Description
eICIC Partnership This section provides statistics on eICIC partnerships. Index Name
Description
cNum
Cell Id
pcID
PartnerCell ID
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CompositeAvailCa pa
%
Average value of the composite availability capacity
Y
SI
10s
float
0~100
CompositeAvail CapaTot/Comp ositeAvailCapa Cnt
sum(CompositeA vailCapaTot)/sum (CompositeAvail CapaCnt)
CompositeAvailCa paTot
%
Sum of CompositeAvailCapa collected
-
SI
10s
float
0~3.4*10^38
-
-
CompositeAvailCa paCnt
count
Collection count of CompositeAvailCapa
-
SI
10s
int
0~2147483647
-
-
DLABSstatus
%
Average use rate of ABS resources
Y
SI
10s
float
0~100
DLABSstatusTo t/DLABSstatusC nt
sum(DLABSstatu sTot)/sum(DLAB SstatusCnt)
DLABSstatusTot
%
Total DLABSstatus statistics
-
SI
10s
float
0~3.4*10^38
-
-
DLABSstatusCnt
count
Collection count of DLABSstatus
-
SI
10s
int
0~2147483647
-
-
CREUECount
count
Average number of CRE UEs per partnership cell
Y
SI
10s
float
0~3.4*10^38
CREUECountT ot/CREUECoun
sum(CREUECou ntTot)/sum(CREU
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
938
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula tCnt
Hourly, Daily, Monthly Formula ECountCnt)
CREUECountTot
count
Sum of CREUECount
-
SI
10s
float
0~3.4*10^38
-
-
CREUECountCnt
count
Collection count of CREUECount
-
SI
10s
int
0~2147483647
-
-
EICICHOAtt
count
Number of handover out attempts made by the CRE operation during the eICIC function
Y
CC
10s
int
0~2147483647
-
-
EICICHOSucc
count
Number of successful handover outs made by the CRE operation during the eICIC function
Y
CC
10s
int
0~2147483647
-
-
EICICPartnershipC nt
count
Collection count of eICIC Partnership
-
CC
10s
int
0~2147483647
-
-
EICICPartnershipC id
pcID
pcID of which collection is requested
-
OW
10s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
939
Chapter 2 Counter Description
eICIC ABS Pattern Info This section provides information on ABS pattern use when eICIC is applied. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AvgABS Num
count
The average number of ABS pattern uses during the collection interval.
The average number of ABS pattern uses during the collection interval.
Y
OW
Period
float
0~23
(0*ABSBin0UsedCnt+5*AB SBin5UsedCnt+6*ABSBin6 UsedCnt+7*ABSBin7UsedC nt+8*ABSBin8UsedCnt+9*A BSBin9UsedCnt+10*ABSBi n10UsedCnt+11*ABSBin11 UsedCnt+12*ABSBin12Use dCnt+13*ABSBin13UsedCn t+14*ABSBin14UsedCnt+15 *ABSBin15UsedCnt+16*AB SBin16UsedCnt+17*ABSBi n17UsedCnt+18*ABSBin18 UsedCnt+19*ABSBin19Use dCnt+20*ABSBin20UsedCn t+21*ABSBin21UsedCnt+22 *ABSBin22UsedCnt+23*AB SBin23UsedCnt)/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC
(0*sum(ABSBin0UsedCnt)+5 *sum(ABSBin5UsedCnt)+6*s um(ABSBin6UsedCnt)+7*su m(ABSBin7UsedCnt)+8*sum (ABSBin8UsedCnt)+9*sum(A BSBin9UsedCnt)+10*sum(A BSBin10UsedCnt)+11*sum(A BSBin11UsedCnt)+12*sum(A BSBin12UsedCnt)+13*sum(A BSBin13UsedCnt)+14*sum(A BSBin14UsedCnt)+15*sum(A BSBin15UsedCnt)+16*sum(A BSBin16UsedCnt)+17*sum(A BSBin17UsedCnt)+18*sum(A BSBin18UsedCnt)+19*sum(A BSBin19UsedCnt)+20*sum(A BSBin20UsedCnt)+21*sum(A BSBin21UsedCnt)+22*sum(A BSBin22UsedCnt)+23*sum(A BSBin23UsedCnt))/(sum(AB
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
940
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt)
ABSBin0
%
The ratio of macro cells to which an ABS pattern was not allocated during the collection interval.
This counter is calculated when measurem ent period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Y
OW
Period
float
0~100
ABSBin0UsedCnt/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt) *100
Hourly, Daily, Monthly Formula SBin0UsedCnt)+sum(ABSBi n5UsedCnt)+sum(ABSBin6U sedCnt)+sum(ABSBin7Used Cnt)+sum(ABSBin8UsedCnt) +sum(ABSBin9UsedCnt)+su m(ABSBin10UsedCnt)+sum( ABSBin11UsedCnt)+sum(AB SBin12UsedCnt)+sum(ABSB in13UsedCnt)+sum(ABSBin1 4UsedCnt)+sum(ABSBin15U sedCnt)+sum(ABSBin16Use dCnt)+sum(ABSBin17UsedC nt)+sum(ABSBin18UsedCnt) +sum(ABSBin19UsedCnt)+s um(ABSBin20UsedCnt)+sum (ABSBin21UsedCnt)+sum(A BSBin22UsedCnt)+sum(ABS Bin23UsedCnt)) sum(ABSBin0UsedCnt)/(sum (ABSBin0UsedCnt)+sum(AB SBin5UsedCnt)+sum(ABSBi n6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su 941
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin5
%
The use rate for the ABS pattern with an ABS ratio of 5/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin5UsedCnt/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt) *100
sum(ABSBin5UsedCnt)/(sum (ABSBin0UsedCnt)+sum(AB SBin5UsedCnt)+sum(ABSBi n6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin6
%
The use rate for the ABS pattern with an ABS ratio of 6/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin6UsedCnt/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS
sum(ABSBin6UsedCnt)/(sum (ABSBin0UsedCnt)+sum(AB SBin5UsedCnt)+sum(ABSBi n6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
942
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt) *100
Hourly, Daily, Monthly Formula edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin7
%
The use rate for the ABS pattern with an ABS ratio of 7/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin7UsedCnt/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt) *100
sum(ABSBin7UsedCnt)/(sum (ABSBin0UsedCnt)+sum(AB SBin5UsedCnt)+sum(ABSBi n6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin8
%
The use rate for the ABS pattern with an ABS ratio of 8/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin8UsedCnt/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used
sum(ABSBin8UsedCnt)/(sum (ABSBin0UsedCnt)+sum(AB SBin5UsedCnt)+sum(ABSBi n6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
943
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
the collection interval.
Granularity Formula Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt) *100
Hourly, Daily, Monthly Formula BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin9
%
The use rate for the ABS pattern with an ABS ratio of 9/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin9UsedCnt/(ABSBin0 UsedCnt+ABSBin5UsedCnt +ABSBin6UsedCnt+ABSBin 7UsedCnt+ABSBin8UsedC nt+ABSBin9UsedCnt+ABSB in10UsedCnt+ABSBin11Us edCnt+ABSBin12UsedCnt+ ABSBin13UsedCnt+ABSBin 14UsedCnt+ABSBin15Used Cnt+ABSBin16UsedCnt+AB SBin17UsedCnt+ABSBin18 UsedCnt+ABSBin19UsedC nt+ABSBin20UsedCnt+ABS Bin21UsedCnt+ABSBin22U sedCnt+ABSBin23UsedCnt) *100
sum(ABSBin9UsedCnt)/(sum (ABSBin0UsedCnt)+sum(AB SBin5UsedCnt)+sum(ABSBi n6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 0
%
The use rate for the ABS pattern with an ABS ratio of 10/40 relative to all Almost Blank
This counter is calculated when measurem
Y
OW
Period
float
0~100
ABSBin10UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS
sum(ABSBin10UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
944
Chapter 2 Counter Description Name
Unit
Description
Trigger
Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
ent period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Hourly, Daily, Monthly Formula Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 1
%
The use rate for the ABS pattern with an ABS ratio of 11/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin11UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
sum(ABSBin11UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1
%
The use rate for
This
Y
OW
Period
float
0~100
ABSBin12UsedCnt/(ABSBin
sum(ABSBin12UsedCnt)/(su
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
945
Chapter 2 Counter Description Name
Unit
2
ABSBin1 3
%
Description
Trigger
the ABS pattern with an ABS ratio of 12/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
counter is calculated when measurem ent period comes.
The use rate for the ABS pattern with an ABS ratio of 13/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Y
OW
Period
float
0~100
ABSBin13UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Hourly, Daily, Monthly Formula m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100 sum(ABSBin13UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su 946
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 4
%
The use rate for the ABS pattern with an ABS ratio of 14/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin14UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
sum(ABSBin14UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 5
%
The use rate for the ABS pattern with an ABS ratio of 15/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin15UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB
sum(ABSBin15UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
947
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Hourly, Daily, Monthly Formula edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 6
%
The use rate for the ABS pattern with an ABS ratio of 16/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin16UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
sum(ABSBin16UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 7
%
The use rate for the ABS pattern with an ABS ratio of 17/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin17UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use
sum(ABSBin17UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
948
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
the collection interval.
Granularity Formula dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Hourly, Daily, Monthly Formula BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 8
%
The use rate for the ABS pattern with an ABS ratio of 18/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin18UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
sum(ABSBin18UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin1 9
%
The use rate for the ABS pattern with an ABS ratio of 19/40 relative to all Almost Blank
This counter is calculated when measurem
Y
OW
Period
float
0~100
ABSBin19UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS
sum(ABSBin19UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
949
Chapter 2 Counter Description Name
Unit
Description
Trigger
Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
ent period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Hourly, Daily, Monthly Formula Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin2 0
%
The use rate for the ABS pattern with an ABS ratio of 20/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin20UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
sum(ABSBin20UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin2
%
The use rate for
This
Y
OW
Period
float
0~100
ABSBin21UsedCnt/(ABSBin
sum(ABSBin21UsedCnt)/(su
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
950
Chapter 2 Counter Description Name
Unit
1
ABSBin2 2
%
Description
Trigger
the ABS pattern with an ABS ratio of 21/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
counter is calculated when measurem ent period comes.
The use rate for the ABS pattern with an ABS ratio of 22/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Y
OW
Period
float
0~100
ABSBin22UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
Hourly, Daily, Monthly Formula m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100 sum(ABSBin22UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su 951
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin2 3
%
The use rate for the ABS pattern with an ABS ratio of 23/40 relative to all Almost Blank Subframes (ABS) patterns that have been applied to macro cells during the collection interval.
This counter is calculated when measurem ent period comes.
Y
OW
Period
float
0~100
ABSBin23UsedCnt/(ABSBin 0UsedCnt+ABSBin5UsedC nt+ABSBin6UsedCnt+ABSB in7UsedCnt+ABSBin8Used Cnt+ABSBin9UsedCnt+ABS Bin10UsedCnt+ABSBin11U sedCnt+ABSBin12UsedCnt +ABSBin13UsedCnt+ABSBi n14UsedCnt+ABSBin15Use dCnt+ABSBin16UsedCnt+A BSBin17UsedCnt+ABSBin1 8UsedCnt+ABSBin19Used Cnt+ABSBin20UsedCnt+AB SBin21UsedCnt+ABSBin22 UsedCnt+ABSBin23UsedC nt)*100
sum(ABSBin23UsedCnt)/(su m(ABSBin0UsedCnt)+sum(A BSBin5UsedCnt)+sum(ABSB in6UsedCnt)+sum(ABSBin7U sedCnt)+sum(ABSBin8Used Cnt)+sum(ABSBin9UsedCnt) +sum(ABSBin10UsedCnt)+s um(ABSBin11UsedCnt)+sum (ABSBin12UsedCnt)+sum(A BSBin13UsedCnt)+sum(ABS Bin14UsedCnt)+sum(ABSBin 15UsedCnt)+sum(ABSBin16 UsedCnt)+sum(ABSBin17Us edCnt)+sum(ABSBin18Used Cnt)+sum(ABSBin19UsedCn t)+sum(ABSBin20UsedCnt)+ sum(ABSBin21UsedCnt)+su m(ABSBin22UsedCnt)+sum( ABSBin23UsedCnt))*100
ABSBin0 UsedCnt
count
The cumulated number of times an ABS pattern was not allocated to a macro cell. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an ABS pattern is not allocated to a macro cell.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin5 UsedCnt
count
The cumulated number of times the ABS pattern
This counter is cumulated
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
952
Chapter 2 Counter Description Name
Unit
Description
Trigger
with an ABS ratio of 5/40 was used. For this counter, statistics are collected periodically.
by 1 when the ABS pattern with an ABS ratio of 5/40 is used.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ABSBin6 UsedCnt
count
The cumulated number of times the ABS pattern with an ABS ratio of 6/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 6/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin7 UsedCnt
count
The cumulated number of times the ABS pattern with an ABS ratio of 7/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 7/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin8 UsedCnt
count
The cumulated number of times the ABS pattern with an ABS ratio of 8/40 was used. For this counter, statistics are
This counter is cumulated by 1 when the ABS pattern with an
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
953
Chapter 2 Counter Description Name
Unit
Description
Trigger
collected periodically.
ABS ratio of 8/40 is used.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ABSBin9 UsedCnt
count
The cumulated number of times the ABS pattern with an ABS ratio of 9/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 9/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 0UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 10/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 10/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 1UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 11/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 11/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
954
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ABSBin1 2UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 12/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 12/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 3UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 13/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 13/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 4UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 14/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 14/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 5UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio
This counter is cumulated by 1 when
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
955
Chapter 2 Counter Description Name
Unit
Description
Trigger
of 15/40 was used. For this counter, statistics are collected periodically.
the ABS pattern with an ABS ratio of 15/40 is used.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ABSBin1 6UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 16/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 16/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 7UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 17/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 17/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin1 8UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 18/40 was used. For this counter, statistics are collected
This counter is cumulated by 1 when the ABS pattern with an ABS ratio
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
956
Chapter 2 Counter Description Name
Unit
Description
Trigger
periodically.
of 18/40 is used.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ABSBin1 9UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 19/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 19/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin2 0UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 20/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 20/40 is used.
-
CC
5.12 s
int
0~21474 83647
-
-
ABSBin2 1UsedC nt
count
The cumulated number of times the ABS pattern with an ABS ratio of 21/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 21/40 is used.
-
CC
5.12 s
int
0~21474 8364
-
-
ABSBin2
count
The cumulated
This
-
CC
5.12 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
957
Chapter 2 Counter Description Name
Unit
2UsedC nt
ABSBin2 3UsedC nt
count
Description
Trigger
number of times the ABS pattern with an ABS ratio of 22/40 was used. For this counter, statistics are collected periodically.
counter is cumulated by 1 when the ABS pattern with an ABS ratio of 22/40 is used.
The cumulated number of times the ABS pattern with an ABS ratio of 23/40 was used. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when the ABS pattern with an ABS ratio of 23/40 is used.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
-
-
8364
-
CC
5.12 s
int
0~21474 8364
958
Chapter 2 Counter Description
GTP This section provides statistics on the GPRS Tunneling Protocol (GTP). The GPRS Tunneling Protocol Block (GTPB) handles the GPRS Tunneling Protocol for data access from the S1-U or X2-U, manages the GTP tunnels for the E-RAB, and transmits/receives user data. GTP statistics are on the GTP layer packets that are received from the S1-U (S-GW) over the downlink, which allow the operator to detect the backhaul condition.
GTP Sequence Number per QCI This section provides statistics on the count of lost downlink packets and the count of Out of Sequence downlink packets in the GTP layer. Index Name
Description
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
GtpSnQciPeakL oss
count
The cumulated number of downlink GTP packets which have been regarded to be lost until the statistics collection time for each QCI.
When the value is a negative number, the collection cycle has an outof-sequence inflow of packets that are counted
This counter is cumulated for each QCI when receiving the downlink GTP packets which have been regarded to be lost in the order of the GTP sequence
Y
CC
5s
int
-2147483647 ~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
959
Chapter 2 Counter Description Name
GtpSnQciOos
Unit
count
Description
Trigger
as a loss in the previous collection cycle.
numbers.
The cumulated number of out of sequence downlink packets for each QCI until the statistics collection time.
That is, the cumulated number of packets in which the order of the GTP sequence numbers is reversed for each QCI.
This counter is cumulated for each QCI when receiving packets in which the order of the GTP sequence numbers is reversed.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
5s
int
0~2147483647
-
-
Collection Time Figure 581. Collection Time for GTP Sequence Number per QCI
UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet Receive (if loss or oss packet occurs) - GtpSnQciPeakLoss - GtpSnQciOos
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
960
Chapter 2 Counter Description
GTP Sequence Number per eNB This section provides statistics on the count of lost downlink packets and the count of Out of Sequence downlink packets in the GTP layer for the eNB. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
GtpSnEnbPeakL oss
count
The cumulated number of downlink GTP packets which have been regarded to be lost until the statistics collection time. Minus value means that the packets counted as loss at previous collection time have come to out-of-sequence at current collection time.
This counter is cumulated when receiving the downlink GTP packets which have been regarded to be lost by the order of GTP sequence number
Y
CC
5s
int
-2147483647 ~2147483647
-
-
GtpSnEnbOos
count
The cumulated number of Out of Sequence downlink packets (i.e. the accumulated count of packets which order of the GTP Sequence Number is reversed)
This counter is cumulated when receiving the packets which order of the GTP Sequence Number is
Y
CC
5s
int
0~214748364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
961
Chapter 2 Counter Description Name
Unit
Description
GtpSnEnbDLCnt
count
The cumulated number of the downlink GTP packets received until the time of counting the statistic.
GtpSnEnbLossR ate
%
GtpSnEnbOosRa te
%
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is updated when receiving the Downlink GTP packet
Y
CC
5s
int
0~214748364 7
-
-
The calculated ratio of the downlink GTP packets lost against the total packets until the time of collecting the statistics loss packet=GtpSnEnb PeakLoss total packet=GtpSnEnb DLCnt+(GtpSnEnbDLCntGtpSnEnbOos). Minus value means that the packets counted as loss at previous collection time have come to out-ofsequence at current collection time.
This counter is calculated when measurement period comes
Y
OW
Period
float
-100~100
GtpSnEnbP eakLoss/(G tpSnEnbDL Cnt+GtpSn Enb PeakLoss)* 100
sum(GtpSnEnbP eakLoss)/(sum(G tpSnEnbDLCnt)+ sum(GtpSnEnb PeakLoss))*100
Total GTP Packet OOS rate per eNB
This counter is calculated when measurement period comes
Y
OW
Period
float
0~100
GtpSnEnb Oos/GtpSn EnbDLCnt* 100
sum(GtpSnEnbO os)/sum(GtpSnE nbDLCnt)*100
reversed
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
962
Chapter 2 Counter Description
Collection Time Figure 582. Collection Time for GTP Sequence Number per eNB UE
eNB
MME
S/GW
RRC_CONNECTED
Downlink DRB Packet Receive - GtpSnEnbDLCnt (if loss or oss packet occurs) - GtpSnEnbPeakLoss - GtpSnEnbOos
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
963
Chapter 2 Counter Description
GTP Forward Traffic This section provides statistics on the GTP Forward Traffic that is defined as the downlink/uplink count/byte/throughput of forwarding traffic during calls, S1/X2 handovers and inter-RAT S1/X2 handovers. In the statistics items, the DL is based on the received packets. The UL is based on the transmitted packets. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CntGtpDLEnbS 1Nor
count
The cumulated number of S1 downlink GTP packets during the basis call.
This counter is cumulated when receiving the S1 downlink GTP packets during the basis call.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpULEnbS 1Nor
count
The cumulated number of S1 uplink GTP packets during the basis call.
This counter is cumulated when receiving the S1 uplink GTP packets during the basis call.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpDLEnbS 1Fw
count
The cumulated number of forwarded packets received in the S1 downlink during the S1 handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink
Y
CC
20 s
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
964
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
during the S1 handover. CntGtpULEnbS 1Fw
count
The cumulated number of packets forwarded to the S1 uplink during the S1 handover.
This counter is cumulated when forwarding packets to the S1 uplink during the S1 handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpDLEnbX 2Fw
count
The cumulated number of forwarded packets received in the X2 downlink during the X2 handover.
This counter is cumulated when receiving the forwarded packets in the X2 downlink during the X2 handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpULEnbX 2Fw
count
The cumulated number of packets forwarded to the X2 uplink during the X2 handover.
This counter is cumulated when forwarding packets to the X2 uplink during the X2 handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpDLEnbI RatUtranS1Fw
count
The cumulated number of forwarded packets received in the S1 downlink during the inter-RAT (UTRAN) handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink during the inter-RAT (UTRAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpULEnbI RatUtranS1Fw
count
The cumulated number of packets forwarded to the S1 uplink during the inter-RAT (UTRAN) handover.
This counter is cumulated when forwarding packets to the S1 uplink during the inter-RAT
Y
CC
20 s
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
965
Chapter 2 Counter Description Name
Unit
Description
CntGtpDLEnbI RatUtranX2Fw
count
The cumulated number of forwarded packets received in the X2 downlink during the inter-RAT (UTRAN) handover.
CntGtpULEnbI RatUtranX2Fw
count
CntGtpDLEnbI RatGeranS1Fw
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when receiving the forwarded packets in the X2 downlink during the inter-RAT (UTRAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
The cumulated number of packets forwarded to the X2 uplink during the inter-RAT (UTRAN) handover.
This counter is cumulated when forwarding packets to the X2 uplink during the inter-RAT (UTRAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
count
The cumulated number of forwarded packets received in the S1 downlink during the inter-RAT (GERAN) handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpULEnbI RatGeranS1Fw
count
The cumulated number of packets forwarded to the S1 uplink during the inter-RAT (GERAN) handover.
This counter is cumulated when forwarding packets to the S1 uplink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpDLEnbI RatGeranX2Fw
count
The cumulated number of forwarded packets received in the X2 downlink during the inter-RAT (GERAN) handover.
This counter is cumulated when receiving the forwarded packets in the X2 downlink during the inter-RAT
Y
CC
20 s
int
0~2147483 647
-
-
(UTRAN) handover.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
966
Chapter 2 Counter Description Name
Unit
Description
CntGtpULEnbI RatGeranX2Fw
count
The cumulated number of packets forwarded to the X2 uplink during the inter-RAT (GERAN) handover.
CntGtpDLEnbI RatCdma2000 HrpdS1Fw
count
CntGtpULEnbI RatCdma2000 HrpdS1Fw
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated when forwarding packets to the X2 uplink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
The cumulated number of forwarded packets received in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.
Y
CC
20 s
int
0~2147483 647
-
-
count
The cumulated number of packets forwarded to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when forwarding packets to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpDLEnbI RatCdma2000 HrpdX2Fw
count
The cumulated number of forwarded packets received in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when receiving the forwarded packets in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.
Y
CC
20 s
int
0~2147483 647
-
-
CntGtpULEnbI RatCdma2000 HrpdX2Fw
count
The cumulated number of packets forwarded to the X2 uplink during the inter-RAT
This counter is cumulated when forwarding packets
Y
CC
20 s
int
0~2147483 647
-
-
(GERAN) handover.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
967
Chapter 2 Counter Description Name
Unit
Description
Trigger
(CDMA2000 HRPD) handover.
to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ByteGtpDLEnb S1Nor
Kbyte s
The cumulated bytes of S1 downlink GTP packets during the basis call.
This counter is cumulated when receiving the Downlink GTP packet in the S1 during the basis call.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb S1Nor
Kbyte s
The cumulated bytes of S1 uplink GTP packets during the basis call.
This counter is cumulated when receiving the Uplink GTP packet in the S1 during the basis call.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb S1Fw
Kbyte s
The cumulated bytes of forwarded packets received in the S1 downlink during the S1 handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink during the S1 handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb S1Fw
Kbyte s
The cumulated bytes of packets forwarded to the S1 uplink during the S1 handover.
This counter is cumulated when forwarding packets to the S1 uplink during the S1 handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb X2Fw
Kbyte s
The cumulated bytes of forwarded packets received in the X2 downlink during the
This counter is cumulated when receiving forwarded
Y
CC
20 s
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
968
Chapter 2 Counter Description Name
Unit
Description
Trigger
X2 handover.
packets in the X2 downlink during the X2 handover.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ByteGtpULEnb X2Fw
Kbyte s
The cumulated bytes of packets forwarded to the X2 uplink during the X2 handover.
This counter is cumulated when forwarding packets to the X2 uplink during the X2 handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb IRatUtranS1Fw
Kbyte s
The cumulated bytes of forwarded packets received in the S1 downlink during the inter-RAT (UTRAN) handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink during the inter-RAT (UTRAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb IRatUtranS1Fw
Kbyte s
The cumulated bytes of packets forwarded to the S1 uplink during the inter-RAT (UTRAN) handover.
This counter is cumulated when forwarding packets to the S1 uplink during the inter-RAT (UTRAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb IRatUtranX2Fw
Kbyte s
The cumulated bytes of forwarded packets received in the X2 downlink during the inter-RAT (UTRAN) handover.
This counter is cumulated when receiving forwarded packets in the X2 downlink during the inter-RAT (UTRAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb IRatUtranX2Fw
Kbyte s
The cumulated bytes of packets forwarded to the X2 uplink during the inter-RAT (UTRAN) handover.
This counter is cumulated when forwarding packets to the X2 uplink
Y
CC
20 s
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
969
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
during the inter-RAT (UTRAN) handover. ByteGtpDLEnb IRatGeranS1F w
Kbyte s
The cumulated bytes of forwarded packets received in the S1 downlink during the inter-RAT (GERAN) handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb IRatGeranS1F w
Kbyte s
The cumulated bytes of packets forwarded to the S1 uplink during the inter-RAT (GERAN) handover.
This counter is cumulated when forwarding packets to the S1 uplink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb IRatGeranX2F w
Kbyte s
The cumulated bytes of forwarded packets received in the X2 downlink during the inter-RAT (GERAN) handover.
This counter is cumulated when receiving the forwarded packets in the X2 downlink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb IRatGeranX2F w
Kbyte s
The cumulated bytes of packets forwarded to the X2 uplink during the inter-RAT (GERAN) handover.
This counter is cumulated when forwarding packets to the X2 uplink during the inter-RAT (GERAN) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb IRatCdma2000 HrpdS1Fw
Kbyte s
The cumulated bytes of forwarded packets received in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when receiving the forwarded packets in the S1 downlink
Y
CC
20 s
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
970
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
during the inter-RAT (CDMA2000 HRPD) handover. ByteGtpULEnb IRatCdma2000 HrpdS1Fw
Kbyte s
The cumulated bytes of packets forwarded to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when forwarding packet to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpDLEnb IRatCdma2000 HrpdX2Fw
Kbyte s
The cumulated bytes of forwarded packets received in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when receiving the forwarded packets in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ByteGtpULEnb IRatCdma2000 HrpdX2Fw
Kbyte s
The cumulated bytes of packets forwarded to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is cumulated when forwarding packets to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover.
Y
CC
20 s
int
0~2147483 647
-
-
ThruGtpDLEnb S1Nor
Kbps
The average throughput of S1 downlink GTP packet in the basis call
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbS1Nor *8*K_UNIT )/ThruGtpD LEnbS1Nor Cnt/1000
(sum(ByteGtpDLE nbS1Nor)*8*K_UN IT)/sum(ThruGtpD LEnbS1NorCnt)/1 000
ThruGtpDLEnb S1NorTot
Kbps
The cumulated number of ThruGtpDLEnbS1Nor
This counter is cumulated by the
-
CC
20 s
float
0~3.4*10^3 8
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
971
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of ThruGtpDLEnbS1N or when it collected ThruGtpDLEnb S1NorCnt
s
The cumulated collection time of ThruGtpDLEnbS1Nor
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb S1Nor
Kbps
The average throughput of S1 uplink GTP packet in the basis call
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbS1Nor *8*K_UNIT )/ThruGtpU LEnbS1Nor Cnt/1000
(sum(ByteGtpULE nbS1Nor)*8*K_UN IT)/sum(ThruGtpU LEnbS1NorCnt)/1 000
ThruGtpULEnb S1NorTot
Kbps
The cumulated number of ThruGtpULEnbS1Nor
This counter is cumulated by the number of ThruGtpULEnbS1N or when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb S1NorCnt
s
The cumulated collection time of ThruGtpULEnbS1Nor
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb S1Fw
Kbps
The average throughput of forwarded packets received in the S1 downlink during the S1 handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbS1Fw *8*K_UNIT )/ThruGtpD LEnbS1Fw Cnt/1000
(sum(ByteGtpDLE nbS1Fw)*8*K_UNI T)/sum(ThruGtpD LEnbS1FwCnt)/10 00
ThruGtpDLEnb S1FwTot
Kbps
The cumulated number of ThruGtpDLEnbS1Fw
This counter is cumulated by the number of ThruGtpDLEnbS1F
-
CC
20 s
float
0~3.4*10^3 8
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
972
Chapter 2 Counter Description Name
Unit
Description
ThruGtpDLEnb S1FwCnt
s
The cumulated collection time of ThruGtpDLEnbS1Fw
ThruGtpULEnb S1Fw
Kbps
ThruGtpULEnb S1FwTot
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
The average throughput of packets forwarded to the S1 uplink during the S1 handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbS1Fw *8*K_UNIT )/ThruGtpU LEnbS1Fw Cnt/1000
(sum(ByteGtpULE nbS1Fw)*8*K_UNI T)/sum(ThruGtpU LEnbS1FwCnt)/10 00
Kbps
The cumulated number of ThruGtpULEnbS1Fw
This counter is cumulated by the number of ThruGtpULEnbS1F w when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb S1FwCnt
s
The cumulated collection time of ThruGtpULEnbS1Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb X2Fw
Kbps
The average throughput of forwarded packets received in the X2 downlink during the X2 handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbX2Fw *8*K_UNIT )/ThruGtpD LEnbX2Fw Cnt/1000
(sum(ByteGtpDLE nbX2Fw)*8*K_UNI T)/sum(ThruGtpD LEnbX2FwCnt)/10 00
ThruGtpDLEnb X2FwTot
Kbps
The cumulated number of ThruGtpDLEnbX2Fw
This counter is cumulated by the number of ThruGtpDLEnbX2F w when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpDLEnb
s
The cumulated collection
This counter is
-
OW
period
int
0~60*Perio
-
-
w when it collected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
973
Chapter 2 Counter Description Name
Unit
X2FwCnt
Description
Trigger
time of ThruGtpDLEnbX2Fw
calculated when measure period comes
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
d
ThruGtpULEnb X2Fw
Kbps
The average throughput of packets forwarded to the X2 uplink during the X2 handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbX2Fw *8*K_UNIT )/ThruGtpU LEnbX2Fw Cnt/1000
(sum(ByteGtpULE nbX2Fw)*8*K_UNI T)/sum(ThruGtpU LEnbX2FwCnt)/10 00
ThruGtpULEnb X2FwTot
Kbps
The cumulated number of ThruGtpULEnbX2Fw
This counter is cumulated by the number of ThruGtpULEnbX2F w when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb X2FwCnt
s
The cumulated collection time of ThruGtpULEnbX2Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb IRatUtranS1Fw
Kbps
The average throughput of forwarded packets received in the S1 downlink during the inter-RAT (UTRAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbIRatUt ranS1Fw*8 *K_UNIT)/T hruGtpDLE nbIRatUtra nS1FwCnt/ 1000
(sum(ByteGtpDLE nbIRatUtranS1Fw) *8*K_UNIT)/sum( ThruGtpDLEnbIRa tUtranS1FwCnt)/1 000
ThruGtpDLEnb IRatUtranS1Fw Tot
Kbps
The cumulated number of ThruGtpDLEnbIRatUtranS1F w
This counter is cumulated by the number of ThruGtpDLEnbIRat UtranS1Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
974
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ThruGtpDLEnb IRatUtranS1Fw Cnt
s
The cumulated collection time of ThruGtpDLEnbIRatUtranS1F w
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb IRatUtranS1Fw
Kbps
The average throughput of packets forwarded to the S1 uplink during the inter-RAT (UTRAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbIRatUt ranS1Fw*8 *K_UNIT)/T hruGtpULE nbIRatUtra nS1FwCnt/ 1000
(sum(ByteGtpULE nbIRatUtranS1Fw) *8*K_UNIT)/sum( ThruGtpULEnbIRa tUtranS1FwCnt)/1 000
ThruGtpULEnb IRatUtranS1Fw Tot
Kbps
The cumulated number of ThruGtpULEnbIRatUtranS1F w
This counter is cumulated by the number of ThruGtpULEnbIRat UtranS1Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb IRatUtranS1Fw Cnt
s
The cumulated collection time of ThruGtpULEnbIRatUtranS1F w
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb IRatUtranX2Fw
Kbps
The average throughput of forwarded packets received in the X2 downlink during the inter-RAT (UTRAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbIRatUt ranX2Fw*8 *K_UNIT)/T hruGtpDLE nbIRatUtra nX2FwCnt/ 1000
(sum(ByteGtpDLE nbIRatUtranX2Fw) *8*K_UNIT)/sum( ThruGtpDLEnbIRa tUtranX2FwCnt)/1 000
ThruGtpDLEnb IRatUtranX2Fw Tot
Kbps
The cumulated number of ThruGtpDLEnbIRatUtranX2F w
This counter is cumulated by the number of
-
CC
20 s
float
0~3.4*10^3 8
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
975
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ThruGtpDLEnbIRat UtranX2Fw when it collected ThruGtpDLEnb IRatUtranX2Fw Cnt
s
The cumulated collection time of ThruGtpDLEnbIRatUtranX2F w
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb IRatUtranX2Fw
Kbps
The average throughput of packets forwarded to the X2 uplink during the inter-RAT (UTRAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbIRatUt ranX2Fw*8 *K_UNIT)/T hruGtpULE nbIRatUtra nX2FwCnt/ 1000
(sum(ByteGtpULE nbIRatUtranX2Fw) *8*K_UNIT)/sum( ThruGtpULEnbIRa tUtranX2FwCnt)/1 000
ThruGtpULEnb IRatUtranX2Fw Tot
Kbps
The cumulated number of ThruGtpULEnbIRatUtranX2F w
This counter is cumulated by the number of ThruGtpULEnbIRat UtranX2Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb IRatUtranX2Fw Cnt
s
The cumulated collection time of ThruGtpULEnbIRatUtranX2F w
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb IRatGeranS1F w
Kbps
The average bytes of forwarded packets received in the S1 downlink during the inter-RAT (GERAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbIRatG eranS1Fw* 8*K_UNIT)/ ThruGtpDL EnbIRatGe ranS1FwC nt/1000
(sum(ByteGtpDLE nbIRatGeranS1Fw )*8*K_UNIT)/sum( ThruGtpDLEnbIRa tGeranS1FwCnt)/ 1000
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
976
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ThruGtpDLEnb IRatGeranS1F wTot
Kbps
The cumulated number of ThruGtpDLEnbIRatGeranS1 Fw
This counter is cumulated by the number of ThruGtpDLEnbIRat GeranS1Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpDLEnb IRatGeranS1F wCnt
s
The cumulated collection time of ThruGtpDLEnbIRatGeranS1 Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb IRatGeranS1F w
Kbps
The average throughput of packets forwarded to the S1 uplink during the inter-RAT (GERAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbIRatG eranS1Fw* 8*K_UNIT)/ ThruGtpUL EnbIRatGe ranS1FwC nt/1000
(sum(ByteGtpULE nbIRatGeranS1Fw )*8*K_UNIT)/sum( ThruGtpULEnbIRa tGeranS1FwCnt)/ 1000
ThruGtpULEnb IRatGeranS1F wTot
Kbps
The cumulated number of ThruGtpULEnbIRatGeranS1 Fw
This counter is cumulated by the number of ThruGtpULEnbIRat GeranS1Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb IRatGeranS1F wCnt
s
The cumulated collection time of ThruGtpULEnbIRatGeranS1 Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb IRatGeranX2F w
Kbps
The average throughput of forwarded packets received in the X2 downlink during the inter-RAT (GERAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbIRatG eranX2Fw* 8*K_UNIT)/ ThruGtpDL
(sum(ByteGtpDLE nbIRatGeranX2Fw )*8*K_UNIT)/sum( ThruGtpDLEnbIRa tGeranX2FwCnt)/
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
977
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula EnbIRatGe ranX2FwC nt/1000
Hourly, Daily, Monthly Formula 1000
ThruGtpDLEnb IRatGeranX2F wTot
Kbps
The cumulated number of ThruGtpDLEnbIRatGeranX2 Fw
This counter is cumulated by the number of ThruGtpDLEnbIRat GeranX2Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpDLEnb IRatGeranX2F wCnt
s
The cumulated collection time of ThruGtpDLEnbIRatGeranX2 Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb IRatGeranX2F w
Kbps
The average throughput of packets forwarded to the X2 uplink during the inter-RAT (GERAN) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbIRatG eranX2Fw* 8*K_UNIT)/ ThruGtpUL EnbIRatGe ranX2FwC nt/1000
(sum(ByteGtpULE nbIRatGeranX2Fw )*8*K_UNIT)/sum( ThruGtpULEnbIRa tGeranX2FwCnt)/ 1000
ThruGtpULEnb IRatGeranX2F wTot
Kbps
The cumulated number of ThruGtpULEnbIRatGeranX2 Fw
This counter is cumulated by the number of ThruGtpULEnbIRat GeranX2Fw when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb IRatGeranX2F wCnt
s
The cumulated collection time of ThruGtpULEnbIRatGeranX2 Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb
Kbps
The average throughput of
This counter is
Y
OW
period
float
0~3.4*10^3
(ByteGtpD
(sum(ByteGtpDLE
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
978
Chapter 2 Counter Description Name
Unit
IRatCdma2000 HrpdS1Fw
Description
Trigger
forwarded packets received in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.
calculated when measure period comes
Visible
Counter Type
Trigger Type
Data Type
Min/Max 8
Granularity Formula LEnbIRatC dma2000H rpdS1Fw*8 *K_UNIT)/T hruGtpDLE nbIRatCdm a2000Hrpd S1FwCnt/1 000
Hourly, Daily, Monthly Formula nbIRatCdma2000 HrpdS1Fw)*8*K_ UNIT)/sum(ThruGt pDLEnbIRatCdma 2000HrpdS1FwCn t)/1000
ThruGtpDLEnb IRatCdma2000 HrpdS1FwTot
Kbps
The cumulated number of ThruGtpDLEnbIRatCdma200 0HrpdS1Fw
This counter is cumulated by the number of ThruGtpDLEnbIRat Cdma2000HrpdS1F w when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpDLEnb IRatCdma2000 HrpdS1FwCnt
s
The cumulated collection time of ThruGtpDLEnbIRatCdma200 0HrpdS1Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb IRatCdma2000 HrpdS1Fw
Kbps
The average throughput of packets forwarded to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbIRatC dma2000H rpdS1Fw*8 *K_UNIT)/T hruGtpULE nbIRatCdm a2000Hrpd S1FwCnt/1 000
(sum(ByteGtpULE nbIRatCdma2000 HrpdS1Fw)*8*K_ UNIT)/sum(ThruGt pULEnbIRatCdma 2000HrpdS1FwCn t)/1000
ThruGtpULEnb IRatCdma2000 HrpdS1FwTot
Kbps
The cumulated number of ThruGtpULEnbIRatCdma200 0HrpdS1Fw
This counter is cumulated by the number of ThruGtpULEnbIRat
-
CC
20 s
float
0~3.4*10^3 8
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
979
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Cdma2000HrpdS1F w when it collected ThruGtpULEnb IRatCdma2000 HrpdS1FwCnt
s
The cumulated collection time of ThruGtpULEnbIRatCdma200 0HrpdS1Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
ThruGtpDLEnb IRatCdma2000 HrpdX2Fw
Kbps
The average throughput of forwarded packets received in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^3 8
(ByteGtpD LEnbIRatC dma2000H rpdX2Fw*8 *K_UNIT)/T hruGtpDLE nbIRatCdm a2000Hrpd X2FwCnt/1 000
(sum(ByteGtpDLE nbIRatCdma2000 HrpdX2Fw)*8*K_ UNIT)/sum(ThruGt pDLEnbIRatCdma 2000HrpdX2FwCn t)/1000
ThruGtpDLEnb IRatCdma2000 HrpdX2FwTot
Kbps
The cumulated number of ThruGtpDLEnbIRatCdma200 0HrpdX2Fw
This counter is cumulated by the number of ThruGtpDLEnbIRat Cdma2000HrpdX2F w when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpDLEnb IRatCdma2000 HrpdX2FwCnt
s
The cumulated collection time of ThruGtpDLEnbIRatCdma200 0HrpdX2Fw
This counter is calculated when measure period comes
OW
period
int
0~60*Perio d
-
-
ThruGtpULEnb IRatCdma2000 HrpdX2Fw
Kbps
The average throughput of packets forwarded to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover.
This counter is calculated when measure period comes
OW
period
float
0~3.4*10^3 8
(ByteGtpU LEnbIRatC dma2000H rpdX2Fw*8 *K_UNIT)/T hruGtpULE nbIRatCdm
(sum(ByteGtpULE nbIRatCdma2000 HrpdX2Fw)*8*K_ UNIT)/sum(ThruGt pULEnbIRatCdma 2000HrpdX2FwCn t)/1000
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Y
980
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula a2000Hrpd X2FwCnt/1 000
Hourly, Daily, Monthly Formula
ThruGtpULEnb IRatCdma2000 HrpdX2FwTot
Kbps
The cumulated number of ThruGtpULEnbIRatCdma200 0HrpdX2Fw
This counter is cumulated by the number of ThruGtpULEnbIRat Cdma2000HrpdX2F w when it collected
-
CC
20 s
float
0~3.4*10^3 8
-
-
ThruGtpULEnb IRatCdma2000 HrpdX2FwCnt
s
The cumulated collection time of ThruGtpULEnbIRatCdma200 0HrpdX2Fw
This counter is calculated when measure period comes
-
OW
period
int
0~60*Perio d
-
-
Collection Time Figure 583. Collection Time for GTP Forward Traffic UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet Send - CntGtpULEnbS1Nor - ByteGtpULEnbS1Nor Downlink DRB Packet Receive - CntGtpDLEnbS1Nor - ByteGtpDLEnbS1Nor
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
981
Chapter 2 Counter Description Figure 584. Collection Time for GTP Forward Traffic UE
Source eNB
S/GW
Target eNB
RRC_CONNECTED
Forward Traffic Send - CntGtpULEnbS1Fw - CntGtpULEnbIRatUtransS1Fw - CntGtpULEnbIRatGeranS1Fw - CntGtpULEnblRatCdma2000HrpdS1Fw - ByteGtpULEnbS1Fw - ByteGtpULEnblRatUtransS1Fw - ByteGtpULEnblratGeranS1Fw - ByteGtpULEnbSlRatCdma2000HrpdS1Fw
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Forward Traffic Receive - CntGtpDLEnbS1Fw - CntGtpDLEnbIRatUtransS1Fw - CntGtpDLEnbIRatGeranS1Fw - CntGtpDLEnblRatCdma2000HrpdS1Fw - ByteGtpDLEnbS1Fw - ByteGtpDLEnblRatUtransS1Fw - ByteGtpDLEnblratGeranS1Fw - ByteGtpDLEnbSlRatCdma2000HrpdS1Fw
982
Chapter 2 Counter Description Figure 585. Collection Time for GTP Forward Traffic UE
Source eNB
Target eNB RRC_CONNECTED
Forward Traffic Send - CntGtpULEnbX2Fw - CntGtpULEnbIRatUtransX2Fw - CntGtpULEnbIRatGeranX2Fw - CntGtpULEnblRatCdma2000HrpdX2Fw - ByteGtpULEnbX2Fw - ByteGtpULEnblRatUtransX2Fw - ByteGtpULEnblratGeranX2Fw - ByteGtpULEnbSlRatCdma2000HrpdX2Fw
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Forward Traffic Receive - CntGtpDLEnbX2Fw - CntGtpDLEnbIRatUtransX2Fw - CntGtpDLEnbIRatGeranX2Fw - CntGtpDLEnblRatCdma2000HrpdX2Fw - ByteGtpDLEnbX2Fw - ByteGtpDLEnblRatUtransX2Fw - ByteGtpDLEnblratGeranX2Fw - ByteGtpDLEnbSlRatCdma2000HrpdX2Fw
983
Chapter 2 Counter Description
SRB This section provides statistics on the Signaling Radio Bearer (SRB, data Plane of PDCP) that provides the Control Plane PDCP SDU bit rates per cell over the downlink and uplink respectively.
Cell PDCP SDU Bit Rate This section provides statistics on the Cell Bit Rate of PDCP SDU. The eNB groups the Control Plane PDCP SDU bit rates per cell by the downlink/uplink in accordance with the 3GPP standard (3GPPTS 32.425 Performance Measurements) and calculates the average value at every measurement interval. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduBitr ateDLAvg
Kbps
The average cell bitrate of the control plane PDCP SDUs over the downlink.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^38
(PdcpSduBitrateDLT ot*8*K_UNIT)/PdcpS duBitrateDLCnt/1000
(sum(PdcpSduBitrate DLTot)*8*K_UNIT)/su m(PdcpSduBitrateDLC nt)/1000
PdcpSduBitr ateDLTot
bytes
The cumulatednumber of
This counter is cumulated
-
CC
2s
float
0~3.4*10^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
984
Chapter 2 Counter Description Name
Unit
Description
Trigger
SRB Packet that is received in the PDCP
when receiving the SRB Packet in the PDCP
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduBitr ateDLCnt
s
The cumulated collection time of PdcpSduBitrateDLAv g
This counter is calculated when measure period comes
-
OW
period
int
0~60*Period
-
-
PdcpSduBitr ateULAvg
Kbps
The average cell bitrate of the control plane PDCP SDUs over the uplink.
This counter is calculated when measure period comes
Y
OW
period
float
0~3.4*10^38
(PdcpSduBitrateULT ot*8)/PdcpSduBitrate ULCnt/1000
(sum(PdcpSduBitrate ULTot)*8)/sum(PdcpS duBitrateULCnt)/1000
PdcpSduBitr ateULTot
bytes
The cumulated number of SRB Packet that is transmitted in the PDCP
This counter is cumulated when transmitting the SRB Packet in the PDCP
-
CC
2s
float
0~3.4*10^38
-
-
PdcpSduBitr ateULCnt
s
The cumulated collection time of PdcpSduBitrateULAv g
This counter is calculated when measure period comes
-
OW
period
int
0~60*Period
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
985
Chapter 2 Counter Description
Collection Time Figure 586. Collection Time for PdcpSduBitrateDLTot UE
eNB
MME
S/GW
Downlink SRB Packet Send - PdcpSduBitrateDLTot
Downlink SRB Packet Receive
Figure 587. Collection Time for PdcpSduBitrateULTot UE
eNB
MME
S/GW
Uplink SRB Packet Receive - PdcpSduBitrateULTot
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Uplink SRB Packet Send
986
Chapter 2 Counter Description
DRB This section provides statistics on the Data Radio Bearer (DRB, User Plane of RLC/MAC) that provides QCI information of the DRB, such as the number of active UEs, packet delay, packet drop rate, packet loss rate and IP latency.
Active UE Number This section provides statistics on the average number of UEs where the buffer data of the DRB is waiting for each QCI. See more information ‘4.1.3 Number of active Ues’ in the 3GPP TS 36.314. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UEActiveD LAvg
count
The calculated number of DL active UEs for each QCI during the collection interval.
This counter indicates the number of UL active UEs per QCI that meet a specific condition during the collection period. The sampling period for this counter is 80 ms (for
Y
SI
5.12 s
float
0~3.4*10^38
UEActiveDLTot /UEActiveDLC nt
sum(UEActiveDL Tot)/sum(UEActiv eDLCnt)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
987
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
more information, see 3GPP TS 36.314). UEs that are targeted for the collection in regard to this counter meets one of the following conditions: There is a Data Radio Bearer (DRB) in the UE during the sampling period and the uplink data which requested to be allocated to the buffer status report is on standby in the DRB. There is a DRB that has received a HARQ retransmission request during the sampling period. UEActiveD LTot
count
The cumulated number of UEActiveDl
This counter is cumulated when UEActiveDl is collected
Y
SI
5.12 s
float
0~3.4*10^38
-
-
UEActiveD LCnt
count
The collection count of UEActiveDl
This counter is cumulated by 1 when UEActiveDl is collected
-
SI
5.12 s
int
0~21474836 47
-
-
UEActiveU LAvg
count
The calculated number of UL active UEs for each QCI during the collection interval.
The number of UEs satisfying one or more of the following conditions in This counter indicates the number of UL active UEs per QCI that meet a
Y
SI
5.12 s
float
0~3.4*10^38
UEActiveULTot /UEActiveULC nt
sum(UEActiveUL Tot)/sum(UEActiv eULCnt)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
988
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
specific condition during the collection period. The sampling period for this counter is 80 ms (for more information, see 3GPP TS 36.314). UEs that are targeted for the collection in regard to this counter meets one of the following conditions: There is a Data Radio Bearer (DRB) in the UE during the sampling period and the uplink data which requested to be allocated to the buffer status report is on standby in the DRB. There is a DRB that has received a HARQ retransmission request during the sampling period. UEActiveU LTot
count
The cumulated number of UEActiveUl
This counter is cumulated when UEActiveUl is collected
Y
SI
5.12 s
float
0~3.4*10^38
-
-
UEActiveU LCnt
count
The collection count of UEActiveUl
This counter is cumulated by 1 when UEActiveUl is collected
-
SI
5.12 s
int
0~21474836 47
-
-
SumActive UEDL
count
This counter is the cumulated number per
This counter is cumulated by 1 per
Y
CC
5.12 s
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
989
Chapter 2 Counter Description Name
SumActive UEUL
Unit
count
Description
Trigger
every TTI of DL DRB for each QCI which receives a buffer occupancy request from the RLC or which has received a HARQ retransmission request during the sampling period.
every TTI when, for each QCI, there is a DL DRB which receives a buffer occupancy request from the RLC or which has received a HARQ retransmission request during the sampling period.
This counter is the cumulated number per every TTI of UL DRB for each QCI where the uplink data requested to be allocated using the Buffer Status Report message is waiting or which received an HARQ retransmission request
This counter is cumulated by 1 per every TTI when, for each QCI, there is a UL DRB where the uplink data requested to be allocated using the Buffer Status Report message is waiting or which received an HARQ retransmission request.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
5.12 s
int
0~21474836 47
-
-
990
Chapter 2 Counter Description
Packet Delay This section provides statistics on the DL PDCP SDU delay defined in the standard 3GPP TS 36.314 for each QCI. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduDelay Avg
ms
Average DL PDCP SDU delay DL PDCP SDU delay on the downlink that occurred for 1 minute.
Y
SI
10 s
float
0~3.4*10^38
PdcpSduDelayTot/ PdcpSduDelayCnt
sum(PdcpSduDelayT ot)/sum(PdcpSduDel ayCnt)
PdcpSduDelay Tot
ms
Sum of PdcpSduDelayAvg collected
Y
SI
10 s
float
0~3.4*10^38
-
-
PdcpSduDelay Cnt
count
Collection count of PdcpSduDelayAvg
-
SI
10 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
991
Chapter 2 Counter Description
Packet Drop Rate This section provides statistics on the per-eNB drop rate for downlink packet drops of the user plane traffic per QCI in accordance with the 3GPP standard (3GPP TS 32.425 Performance Measurements). Packet drops can occur due to traffic congestion and are calculated (in ppm) by multiplying it by 1E6 according to the standard (3GPP TS 36.314 Layer 2-Measurements). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduDropRateD L
ppm
The calculated packet drop rate of downlink SRB Packet which is received in the PDCP
This counter is cumulated when downlink SRB Packet is dropped in the PDCP
Y
SI
1 min
float
0~3.4*10^ 38
PdcpSduDr opRateDLT ot/PdcpSdu DropRateD LCnt
sum(PdcpSduDrop RateDLTot)/sum(P dcpSduDropRateD LCnt)
PdcpSduDropRateD LTot
ppm
The cumulated number of PdcpSduDropRateDL
This counter is cumulated when PdcpSduDropRate DL is collected
-
SI
1 min
float
0~3.4*10^ 38
-
-
PdcpSduDropRateD LCnt
count
The collection count of PdcpSduDropRateDL
This counter is cumulated by 1 when PdcpSduDropRate DL is collected
-
SI
1 min
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
992
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpPduDropRateD L
ppm
The calculated average DL PDCP SDU drop rate. The DL PDCP SDU drop rate on the downlink that occurred for 1 minute.
This counter is calculated when measurement period comes.
Y
SI
10 s
float
0~3.4*10^ 38
PdcpPduDr opRateDLT ot/PdcpPdu DropRateD LCnt
sum(PdcpPduDrop RateDLTot)/sum(P dcpPduDropRateD LCnt)
PdcpPduDropRateD LTot
ppm
The cumulated number of PdcpPduDropRateDL
This counter is cumulated when PdcpPduDropRate DL is collected
-
SI
10 s
float
0~3.4*10^ 38
-
-
PdcpPduDropRateD LCnt
count
The collection count of PdcpPduDropRateDL
This counter is cumulated by 1 when PdcpPduDropRate DL is collected
-
SI
10 s
int
0~214748 3647
-
-
Collection Time Figure 588. Collection Time for PdcpSduDropRateDL UE
eNB
MME
S/GW
RRC_CONNECTED Downlink DRB Packet Send Fail - PdcpSduDropRateDL
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Downlink DRB Packet Receive
993
Chapter 2 Counter Description
Packet Loss Rate This section provides statistics on the per-eNB loss rate for PDCP SDUs of the user plane traffic that have not been received successfully over the uplink per QCI in accordance with the 3GPP standard (TS32.425 Performance Measurements). The rate is calculated (in ppm) by multiplying 1E6 according to the standard (TS 36.314 Layer 2-Measurements). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduLossR ateUL
ppm
The calculated average loss rate of uplink SRB Packet that is received in the PDCP
This counter is cumulated when the loss occurs in the uplink SRB Packet received from PDCP
Y
SI
1 min
float
0~3.4*10^3 8
PdcpSduLossRa teULTot/PdcpSd uLossRateULCn t
sum(PdcpSduLossRate ULTot)/sum(PdcpSduL ossRateULCnt)
PdcpSduLossR ateULTot
ppm
The cumulated number of PdcpSduLossRat eUL
This counter is cumulated when PdcpSduLossRate UL is collected
-
SI
1 min
float
0~3.4*10^3 8
-
-
PdcpSduLossR ateULCnt
count
The collection count of PdcpSduLossRat
This counter is cumulated by 1 when PdcpSduLossRate
-
SI
1 min
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
994
Chapter 2 Counter Description Name
Unit
Description
Trigger
PdcpSduAirIntf Avg
ppm
PdcpSduAirIntf Tot
PdcpSduAirIntf Cnt
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
eUL
UL is collected
The calculated average DL PDCP SDU loss rate. The DL PDCP SDU packet loss rate on the downlink that occurred for 10 seconds.
This counter is calculated when measurement period comes.
Y
SI
1 min
float
0~3.4*10^3 8
PdcpSduAirIntfT ot/PdcpSduAirIn tfCnt
sum(PdcpSduAirIntfTot )/sum(PdcpSduAirIntfC nt)
ppm
The cumulated number of PdcpSduAirIntfAv g
This counter is cumulated when PdcpSduAirIntfAvg is collected
-
SI
1 min
float
0~3.4*10^3 8
-
-
count
The collection count of PdcpSduAirIntfAv g
This counter is cumulated by 1 when PdcpSduAirIntfAvg is collected
-
SI
1 min
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
995
Chapter 2 Counter Description
Collection Time Figure 589. Collection Time for PdcpSduLossRateUL UE
eNB
MME
S/GW
RRC_CONNECTED
Uplink DRB Packet Receive
Uplink DRB Packet Send
Packet Loss Uplink DRB Packet Receive - PdcpSduLossRateUL
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Uplink DRB Packet Send
996
Chapter 2 Counter Description
IP Latency This section provides the statistics on the DL IP latency defined in the standard 3GPP TS 32.450 for each QCI. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
IpLateDL
ms
IP latency in the downlink, SAE bearer level. IP latency for 10 seconds in the downlink.
Y
SI
10 s
float
0~3.4*10^38
IpLateDLTot/ IpLateDLCnt
sum(IpLateDLTot)/ sum(IpLateDLCnt)
IpLateDLTot
ms
The sum of collected IpLateDL
-
SI
10 s
float
0~3.4*10^38
-
-
IpLateDLCnt
count
Collection count of IpLateDL
-
SI
10 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
997
Chapter 2 Counter Description
RRU This section provides statistics on the Radio Resource Utilization (RRU) that includes DL/UL PRB Usage, DL/UL Total PRB Usage, and Cell Unavailable Time statistics. These statistics items are described in the following tables.
PRB Usage This section provides statistics on the rate (per QCI) of PRB allocated to the DTCH among the total PRB on the DL/UL in the MAC. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PrbDLAvg
%
The average use rate for PRBs used for each QCI in order to transmit DTCH traffic for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
0~100
PrbDLTot/Prb DLCnt
sum(PrbDLTot)/sum(P rbDLCnt)
PrbDLTot
%
The cumulated
This counter is cumulated by
-
SI
5.12 s
float
0~3.4*1
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
998
Chapter 2 Counter Description Name
Unit
Description
Trigger
number of PrbDl
the number of PRB usage when it is used for DTCH traffic transmission per QCI in the downlink
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
0^38
PrbDLCnt
count
The collection count of PrbDl
This counter is cumulated by 1 when PrbDl is collected
-
SI
5.12 s
int
0~21474 83647
-
-
PrbULAvg
%
The average use rate for PRBs used for each QCI in order to transmit DTCH traffic for the uplink during the collection interval.
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
0~100
PrbULTot/Prb ULCnt
sum(PrbULTot)/sum(P rbULCnt)
PrbULTot
%
The cumulated number of PrbUl
This counter is cumulated by the number of PRB usage when it is used for DTCH traffic transmission per QCI in the uplink
-
SI
5.12 s
float
0~3.4*1 0^38
-
-
PrbULCnt
count
The collection count of PrbUl
This counter is cumulated by 1 when PrbUl is collected
-
SI
5.12 s
int
0~21474 83647
-
-
PrbDLCurr
%
The most recent collected PrbDl's value
This counter is updated when PrbDI is collected
-
SI
5.12 s
float
0~100
-
-
PrbULCurr
%
The most recent collected PrbUl's value
This counter is updated when PrbUI is collected
-
SI
5.12 s
float
0~100
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
999
Chapter 2 Counter Description
Total PRB Usage This section provides statistics on the usage rate (percentage) of the PRB on the downlink PDSCH and the uplink PUSCH among the total PRB in the MAC Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotPrbDLAvg
%
The average use rate for PRBs used for each QCI in order to transmit the PDSCH/PBCH for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUGE
5.12 s
float
0~100
TotPrbDLTo t/TotPrbDL Cnt
sum(TotPrbDLTot)/sum( TotPrbDLCnt)
TotPrbDLMin
%
The minimum value of TotPrbDl
This counter is updated when the TotPrbDl is smaller than previous value
-
GAUGE
5.12 s
float
0~100
-
min(TotPrbDLMin)
TotPrbDLMax
%
The maximum value of TotPrbDl
This counter is updated when the TotPrbDl is greater than previous value
-
GAUGE
5.12 s
float
0~100
-
max(TotPrbDLMax)
TotPrbDLTot
%
The cumulated
This counter is
-
GAUGE
5.12 s
float
0~3.4*10
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1000
Chapter 2 Counter Description Name
Unit
Description
Trigger
number of TotPrbDl
cumulated by the number of PRB usage when it is used for PDSCH/PBCH transmission in the downlink
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
^38
TotPrbDLCnt
count
The collection count of TotPrbDl
This counter is cumulated by 1 when TotPrbDl is collected
-
GAUGE
5.12 s
int
0~21474 83647
-
-
TotGbrPrbDL Avg
%
The average use rate for PRBs used for each QCI in order to transmit GBR traffic for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUGE
5.12 s
float
0~100
TotGbrPrbD LTot/TotGbr PrbDLCnt
sum(TotGbrPrbDLTot)/ sum(TotGbrPrbDLCnt)
TotGbrPrbDL Min
%
The minimum value of TotGbrPrbDl
This counter is updated when the TotGbrPrbDl is smaller than previous value
-
GAUGE
5.12 s
float
0~100
-
min(TotGbrPrbDLMin)
TotGbrPrbDL Max
%
The maximum value of TotGbrPrbDl
This counter is updated when the TotGbrPrbDl is greater than previous value
-
GAUGE
5.12 s
float
0~100
-
max(TotGbrPrbDLMax)
TotGbrPrbDL Tot
%
The cumulated number of TotGbrPrbDl
This counter is cumulated by the number of PRB usage when it is used for GBR Traffic transmission in the downlink
-
GAUGE
5.12 s
float
0~3.4*10 ^38
-
-
TotGbrPrbDL Cnt
count
The collection count of TotGbrPrbDl
This counter is cumulated by 1 when
-
GAUGE
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1001
Chapter 2 Counter Description Name
Unit
Description
TotNGbrPrbD LAvg
%
The average use rate for PRBs used for each QCI in order to transmit non-GBR traffic for the downlink during the collection interval.
TotNGbrPrbD LMin
%
TotNGbrPrbD LMax
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is calculated when measurement period comes.
Y
GAUGE
5.12 s
float
0~100
TotNGbrPrb DLTot/TotN GbrPrbDLC nt
sum(TotNGbrPrbDLTot)/ sum(TotNGbrPrbDLCnt)
The minimum value of TotNGbrPrbDl
This counter is updated when the TotNGbrPrbDl is smaller than previous value
-
GAUGE
5.12 s
float
0~100
-
min(TotNGbrPrbDLMin)
%
The maximum value of TotNGbrPrbDl
This counter is updated when the TotNGbrPrbDl is greater than previous value
-
GAUGE
5.12 s
float
0~100
-
max(TotNGbrPrbDLMax )
TotNGbrPrbD LTot
%
The cumulated number of TotNGbrPrbDl
This counter is cumulated by the number of PRB usage when it is used for NonGBR traffic transmission in the downlink
-
GAUGE
5.12 s
float
0~3.4*10 ^38
-
-
TotNGbrPrbD LCnt
count
The collection count of TotNGbrPrbDl
This counter is cumulated by 1 when TotNGbrPrbDl is collected
-
GAUGE
5.12 s
int
0~21474 83647
-
-
TotPrbULAvg
%
The average use rate for PRBs used for each QCI in order to transmit PUSCH for the uplink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUGE
5.12 s
float
0~100
TotPrbULTo t/TotPrbUL Cnt
sum(TotPrbULTot)/sum( TotPrbULCnt)
TotGbrPrbDl is collected
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1002
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotPrbULMin
%
The minimum value of TotPrbUl
This counter is updated when the TotPrbUl is smaller than previous value
-
GAUGE
5.12 s
float
0~100
-
min(TotPrbULMin)
TotPrbULMax
%
The maximum value of TotPrbUl
This counter is updated when the TotPrbUl is greater than previous value
-
GAUGE
5.12 s
float
0~100
-
max(TotPrbULMax)
TotPrbULTot
%
The cumulated number of TotPrbUl
This counter is cumulated by the number of PRB usage when it is used for PUSCH transmission in the downlink
-
GAUGE
5.12 s
float
0~3.4*10 ^38
-
-
TotPrbULCnt
count
The collection count of PrbUL
This counter is cumulated by 1 when TotPrbUl is collected
-
GAUGE
5.12 s
int
0~21474 83647
-
-
TotGbrPrbUL Avg
%
The average use rate for PRBs used for each QCI in order to transmit GBR traffic for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUGE
5.12 s
float
0~100
TotGbrPrbU LTot/TotGbr PrbULCnt
sum(TotGbrPrbULTot)/s um(TotGbrPrbULCnt)
TotGbrPrbUL Min
%
The minimum value of TotGbrPrbUl
This counter is updated when the TotGbrPrbUl is smaller than previous value
-
GAUGE
5.12 s
float
0~100
-
min(TotGbrPrbULMin)
TotGbrPrbUL Max
%
The maximum value of TotGbrPrbUl
This counter is updated when the TotGbrPrbUl is greater than previous value
-
GAUGE
5.12 s
float
0~100
-
max(TotGbrPrbULMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1003
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotGbrPrbUL Tot
%
The cumulated number of TotGbrPrbUl
This counter is cumulated by the number of PRB usage when it is used for GBR traffic transmission in the downlink
-
GAUGE
5.12 s
float
0~3.4*10 ^38
-
-
TotGbrPrbUL Cnt
count
The collection count of TotGbrPrbUl
This counter is cumulated by 1 when TotGbrPrbUl is collected
-
GAUGE
5.12 s
int
0~21474 83647
-
-
TotNGbrPrbU LAvg
%
The average use rate for PRBs used for each QCI in order to transmit non-GBR traffic for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUGE
5.12 s
float
0~100
TotNGbrPrb ULTot/TotN GbrPrbULC nt
sum(TotNGbrPrbULTot)/ sum(TotNGbrPrbULCnt)
TotNGbrPrbU LMin
%
The minimum value of TotNGbrPrbUl
This counter is updated when the TotNGbrPrbUl is smaller than previous value
-
GAUGE
5.12 s
float
0~100
-
min(TotNGbrPrbULMin)
TotNGbrPrbU LMax
%
The maximum value of TotNGbrPrbUl
This counter is updated when the TotNGbrPrbUl is greater than previous value
-
GAUGE
5.12 s
float
0~100
-
max(TotNGbrPrbULMax )
TotNGbrPrbU LTot
%
The cumulated number of TotNGbrPrbUl
This counter is cumulated by the number of PRB usage when it is used for NonGBR traffic transmission in the downlink
-
GAUGE
5.12 s
float
0~3.4*10 ^38
-
-
TotNGbrPrbU LCnt
count
The collection count of TotNGbrPrbUl
This counter is cumulated by 1 when
-
GAUGE
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1004
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotNGbrPrbUl is collected TotPrbDLCur r
%
The most recent collected TotalPrbDl
This counter is updated when TotalPrbDl is collected
-
GAUGE
5.12 s
float
0~100
-
-
TotPrbULCur r
%
The most recent collected TotalPrbUl
This counter is updated when TotalPrbUL is collected
-
GAUGE
5.12 s
float
0~100
-
-
TotPucchPrb ULAvg
%
The average use rate for PRBs used for each QCI in order to transmit the PUCCH for the uplink during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(TotUsedPu cchPrbULN um/TotAvail PrbULNum) *100
(sum(TotUsedPucchPrb ULNum)/sum(TotAvailPr bULNum))*100
TotUsedPucc hPrbULNum
count
The number of PRBs used to receive the PUCCH during the collection interval.
This counter is cumulated by the number of PRBs that were used to receive the PUCCH during the collection interval.
-
CC
5.12 s
int
0~21474 83647
-
-
TotAvailPrbU LNum
count
The total number of PRBs available for the uplink during the collection interval.
This counter is cumulated by the available PRB for each TTI in the uplink
-
CC
5.12 s
int
0~21474 83647
-
-
TotPucchPus chPrbULAvg
%
The average use rate for PRBs used to receive the PUCCH/PUSCH for the uplink during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
((TotUsedP ucchPrbUL Num+TotUs edPuschPrb ULNum)/Tot AvailPrbUL Num)*100
((sum(TotUsedPucchPrb ULNum)+sum(TotUsedP uschPrbULNum))/sum(T otAvailPrbULNum))*100
TotUsedPusc
count
The number of PRBs
This counter is
-
CC
5.12 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1005
Chapter 2 Counter Description Name
Unit
hPrbULNum
Description
Trigger
used to receive PUSCH during the collection interval.
cumulated by the number of PRBs that were used to receive PUSCH during the collection interval.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
TotNgbrSCell PrbDLAvg
%
The average use rate for PRBs used to transmit the SCell's non-GBR traffic for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(TotNgbrSC ellPrbDLNu m/TotAvailP rbDLNum)* 100
(sum(TotNgbrSCellPrbD LNum)/sum(TotAvailPrb DLNum))*100
TotNgbrSCell PrbDLNum
count
The total number of PRBs used to transmit the SCell's non-GBR traffic during the collection interval.
This counter is cumulated by the number of PRBs that were used to allocate the SCell's non-GBR traffic during the collection interval.
-
CC
5.12 s
int
0~21474 83647
-
-
TotAvailPrbD LNum
count
The total number of PRBs available for the downlink during the collection interval.
This counter is cumulated by the total number of PRBs available for the downlink at every TTI.
Y
CC
5.12 s
int
0~21474 83647
(TotUsedPu cchPrbULN um/TotAvail PrbULNum) *100
(sum(TotUsedPucchPrb ULNum)/sum(TotAvailPr bULNum))*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1006
Chapter 2 Counter Description
Total PRB Usage per PLMN This section provides statistics on the total PRB usage including the control data of DL/UL per PLMN. Index Name
Description
PLMN
PLMN Id, the first three digits are MCC and the others are MNC
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PLMNTotPrbD LAvg
%
The average use rate for PRBs used for each QCI in order to transmit the PDSCH/PBCH for the downlink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUG E
5.12 s
float
0~100
PLMNTotPrb DLTot/PLMN TotPrbDLCnt
sum(PLMNTotPrb DLTot)/sum(PLMN TotPrbDLCnt)
PLMNTotPrbD LMin
%
The minimum value of PLMNTotPrbDLAvg
This counter is updated when the PLMNTotPrbDLAvg is smaller than the previous value
Y
GAUG E
5.12 s
float
0~100
-
min(PLMNTotPrbD LMin)
PLMNTotPrbD LMax
%
The maximum value of PLMNTotPrbDLAvg
This counter is updated when the PLMNTotPrbDLAvg is greater than the previous value
Y
GAUG E
5.12 s
float
0~100
-
max(PLMNTotPrb DLMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1007
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PLMNTotPrbD LTot
%
The cumulated number of PLMNTotPrbDLAvg
This counter is cumulated by the number of PRB usage to transmit the PDSCH/PBCH in the downlink
-
GAUG E
5.12 s
float
0~3.4*10 ^38
-
-
PLMNTotPrbD LCnt
count
The collection count of PLMNTotPrbDLAvg
This counter is cumulated by 1 when PLMNTotPrbDLAvg is collected
-
GAUG E
5.12 s
int
0~21474 83647
-
-
PLMNTotPrbU LAvg
%
The average use rate for PRBs used for each QCI in order to transmit PUSCH for the uplink during the collection interval.
This counter is calculated when measurement period comes.
Y
GAUG E
5.12 s
float
0~100
PLMNTotPrb ULTot/PLMN TotPrbULCnt
sum(PLMNTotPrb ULTot)/sum(PLMN TotPrbULCnt)
PLMNTotPrbU LMin
%
The minimum value of PLMNTotPrbULAvg
This counter is updated when the PLMNTotPrbULAvg is smaller than the previous value
Y
GAUG E
5.12 s
float
0~100
-
min(PLMNTotPrbU LMin)
PLMNTotPrbU LMax
%
The maximum value of PLMNTotPrbULAvg
This counter is updated when the PLMNTotPrbULAvg is greater than the previous value
Y
GAUG E
5.12 s
float
0~100
-
max(PLMNTotPrb ULMax)
PLMNTotPrbU LTot
%
The cumulated number of PLMNTotPrbULAvg
This counter is cumulated by the number of PRB usage to transmit PUSCH in the downlink
-
GAUG E
5.12 s
float
0~3.4*10 ^38
-
-
PLMNTotPrbU
count
The collection count
This counter is
-
GAUG
5.12 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1008
Chapter 2 Counter Description Name
Unit
LCnt
Description
Trigger
of PLMNTotPrbULAvg
cumulated by 1 when PLMNTotPrbULAvg is collected
Visible
Counter Type E
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
PLMNTotPrbD LCurr
%
The most recent collected PLMNTotPrbDLAvg
This counter is updated when PLMNTotPrbDLAvg is collected
-
GAUG E
5.12 s
float
0~100
-
-
PLMNTotPrbU LCurr
%
The most recent collected PLMNTotPrbULAvg
This counter is updated when PLMNTotPrbULAvg is collected
-
GAUG E
5.12 s
float
0~100
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1009
Chapter 2 Counter Description
Cell Unavailable Time This section provides statistics on the average locked time and disabled time per unit time. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CellUnavailableTimeLock
s
The cumulated lock time per measurement period.
This counter is calculated when measurement period comes.
Y
CC
1 min
int
0~60*Perio d
-
-
CellUnavailableTimeDown
s
The cumulated disabled time per measurement period.
This counter is calculated when measurement period comes.
Y
CC
1 min
int
0~60*Perio d
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1010
Chapter 2 Counter Description
S1SIG This section provides statistics on the S1 Application Protocol Signalling (S1SIG) that provides UE-associated logical S1-connection establishment statistics.
UE-associated logical S1 Connection Establishment This section provides statistics data for S1 Logical Connection Setup for each cell. When the Initial UE message is transmitted, it is counted as an Attempt; when the first logical S1 Connection message is received from MME, it is counted as a Success. A Failure is counted when a failure or timeout occurs during the procedure and the applicable cause is recorded. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause
RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: delay_tolerant_access: Access by the delay tolerant access
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1011
Chapter 2 Counter Description
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1ConnEstabAtt
count
UE logical S1 connection setup attempt count
Y
CC
event
int
0~2147483647
-
-
S1ConnEstabSuc c
count
UE Logical S1 Connection Setup success count.
Y
CC
event
int
0~2147483647
-
-
S1ConnEstabFail _CpCcFail
count
A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during S1 connection.
Y
CC
event
int
0~2147483647
-
-
S1ConnEstabFail _S1apCuFail
count
A call is released due to the S1AP specification cause during S1 connection.
Y
CC
event
int
0~2147483647
-
-
S1ConnEstabFail _S1apLinkFail
count
A call is released due to S1 SCTP link failure during S1 connection.
Y
CC
event
int
0~2147483647
-
-
S1ConnEstabFail _S1apSigFail
count
A call is released due to receiving S1AP signaling during S1 connection.
Y
CC
event
int
0~2147483647
-
-
S1ConnEstabFail _S1apSigTo
count
A call is released due to S1AP signaling timeout (not received) during S1 connection.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1012
Chapter 2 Counter Description
Collection Time (Success) Figure 590. Collection Time for S1SIG (1) UE
eNB
MME
S/GW
MME
S/GW
RRC_IDLE Initial UE Message
1
Attempt
2
Success
Initial Context Setup Request
RRC_CONNECTED
Figure 591. Collection Time for S1SIG (2) UE
eNB RRC_IDLE Initial UE Message
1
Attempt
2
Success
Downlink NAS Transport
RRC_CONNECTED
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1013
Chapter 2 Counter Description Figure 592. Collection Time for S1SIG (3) UE
eNB
MME
S/GW
RRC_IDLE Initial UE Message
1
Attempt
2
Success
UE Context Release Command
RRC_CONNECTED
Collection Time (Failure) Figure 593. Collection Time for S1ConnEstabFail_S1apSigTo UE
eNB
MME
S/GW
RRC_CONNECTED
Attempt
1
Initial UE Message Initial Context Setup Request Timeout
2 Failure - S1ConnEstabFail_S1apSigTo RRC_CONNECTED
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1014
Chapter 2 Counter Description
S1 Connection Time This section provides statistics on the S1 setup time. It collects the time elapsed from transmitting the Initial UE message to receiving the first message from MME for the Initial UE message by cell and by EstabCause. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause
RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: delay_tolerant_access: Access by the delay tolerant access
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1SigTimeAvg
ms
S1 connection average setup time
Y
GAUGE
event
float
0~3.4*10^38
S1SigTimeTot/ S1SigTimeCnt
sum(S1SigTimeTot)/s um(S1SigTimeCnt)
S1SigTimeMax
ms
Maximum setup time for S1 connection
Y
GAUGE
event
float
0~3.4*10^38
-
max(S1SigTimeMax)
S1SigTimeTot
ms
Accumulated setup time for S1 connection
Y
GAUGE
event
float
0~3.4*10^38
-
-
S1SigTimeCnt
count
Collection count of S1SigTimeAvg
Y
GAUGE
event
int
0~214748364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1015
Chapter 2 Counter Description
Paging This section provides statistics on the paging, which the number of paging attempts by the RRC and number of paging messages that are discarded when the RLC cannot process paging messages upon receipt due to insufficient capacity. The RLC can save up to 4,096 paging messages in each cell.
Paging This section provides statistics on the Paging Performance. The eNB collects the statistics data for the paging attempt for each cell of the base station made by the MME’s paging request. Also, it collects the number of the discarded paging messages that were not processed by the eNB for each cell. The paging for both system information update and ETWA indication is not included. The eNB, which is an access network, does not collect the statistics data for the paging responses that are made through NAS signaling. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DiscardedNbr
count
Paging record count discarded in the eNB
Y
CC
10 s
int
0~2147483647
-
-
AttPaging
count
Paging transmission attempt count
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1016
Chapter 2 Counter Description
Collection Time Figure 594. Collection Time for PAGING UE
eNB
MME
S/GW
RRC_IDLE Paging Request Paging Paging
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1
Attempt
1017
Chapter 2 Counter Description
Overload Protection Denied Call by Overload Protection This section provides statistics on the number of calls that are denied due to the overload prevention function. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Denied_HighPriorityA ccess
count
The number of Priority Access calls that are denied due to the overload prevention function
Y
CC
event
int
0~2147483647
-
-
Denied_moSignaling
count
The number of mo Signaling calls that are denied due to the overload prevention function
Y
CC
event
int
0~2147483647
-
-
Denied_moData
count
The number of mo Data calls that are denied due to the overload prevention function
Y
CC
event
int
0~2147483647
-
-
Denied_DelayTolerant Access
count
The statistics that counts the number of DelayTolerantAccess calls that are denied due to the overload prevention function
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1018
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Denied_Paging
count
The number of paging message that are dumped by the overload prevention function
Y
CC
event
int
0~2147483647
-
-
Power Power This section provides statistics on the average interference over thermal noise for each PRB, the average thermal noise for each cell, the average RSSI for each cell, and the average RSSI for each antenna. See ‘5.2 E-UTRAN measurement abilities’ in the 3GPP TS 36.124. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterferencePo werAvg
dBm
The average value of interference over thermal noise for each PRB
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
-1000~1000
InterferencePow erTot/Interferenc ePowerCnt
sum(InterferencePowerT ot)/sum(InterferencePow erCnt)
InterferencePo werTot
dBm
The cumulated number of InterferencePower
This counter is updated when the InterferencePow er is collected
-
SI
5.12 s
float
-3.4*10^38 ~3.4*10^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1019
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
InterferencePo werCnt
count
The collection count of InterferencePower
This counter is collected by 1 when InterferencePow er is collected
-
SI
5.12 s
int
0~21474836 47
-
-
ThermalNoise PowerAvg
dBm
The average uplink thermal noise power of all UL bandwidths during the collection interval.
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
-1000~1000
ThermalNoisePo werTot/Thermal NoisePowerCnt
sum(ThermalNoisePower Tot)/sum(ThermalNoiseP owerCnt)
ThermalNoise PowerTot
dBm
The cumulated number of ThermalNoisePow er
This counter is collected when ThermalNoisePo wer is collected
-
SI
5.12 s
float
-3.4*10^38 ~3.4*10^38
-
-
ThermalNoise PowerCnt
count
The collection count of ThermalNoisePow er
This counter is collected by 1 when ThermalNoisePo wer is collected
-
SI
5.12 s
int
0~21474836 47
-
-
RssiOverPath Avg
dBm
The average RSSI value for path0 and path1
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
-1000~1000
RssiOverPathTo t/RssiOverPathC nt
sum(RssiOverPathTot)/s um(RssiOverPathCnt)
RssiOverPath Tot
dBm
The cumulated number of RssiOverPath
This counter is updated when the RssiOverPath is collected
-
SI
5.12 s
float
-3.4*10^38 ~3.4*10^38
-
-
RssiOverPath Cnt
count
The collection count RssiOverPath
This counter is collected by 1 when
-
SI
5.12 s
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1020
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RssiOverPath is collected RssiPath0Avg
dBm
The average value of RSSI of path0
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
-1000~1000
RssiPath0Tot/Rs siPath0Cnt
sum(RssiPath0Tot)/sum( RssiPath0Cnt)
RssiPath0Tot
dBm
The cumulated number of RssiPath0
This counter is updated when RssiPath0 is collected
-
SI
5.12 s
float
-3.4*10^38 ~3.4*10^38
-
-
RssiPath0Cnt
count
The collection count RssiPath0
This counter is collected by 1 when RssiPath0 is collected
-
SI
5.12 s
int
0~21474836 47
-
-
RssiPath1Avg
dBm
The average value of RSSI of path1
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
-1000~1000
RssiPath1Tot/Rs siPath1Cnt
sum(RssiPath1Tot)/sum( RssiPath1Cnt)
RssiPath1Tot
dBm
The cumulated number of RssiPath1
This counter is updated when RssiPath1 is collected
-
SI
5.12 s
float
-3.4*10^38 ~3.4*10^38
-
-
RssiPath1Cnt
count
The collection count RssiPath1
This counter is collected by 1 when RssiPath1 is collected
-
SI
5.12 s
int
0~21474836 47
-
-
RssiPath0Curr
dBm
The most recent collected RssiPath0
This counter is updated by the most recent collected RssiPath0
-
SI
5.12 s
float
-1000~1000
-
max(RssiPath0Curr)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1021
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RssiPath1Curr
dBm
The most recent collected RssiPath1
This counter is updated by the most recent collected RssiPath1
-
SI
5.12 s
float
-1000~1000
-
max(RssiPath1Curr)
RRH RSSI This section provides statistics on the Received Signal Strength Indicator (RSSI) values for each RRH path. Index Name
Description
BID
Board ID
RuPort
Ru Port Number
Cascade
Cascade ID
RSSIPath
RSSI Path ID
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RrhRssiAvg
dBm
The average values of RSSI for each RRH path
This counter is calculated when measurement period comes.
Y
GAUGE
10 s
float
-1000~1000
10*(log10(Rrh RssiTot/RrhRs siCnt)-12)
10*(log10(sum(Rrh RssiTot)/sum(RrhR ssiCnt))-12)
RrhRssiMax
dBm
The maximum values of RSSI for each RRH path
This counter is updated when RSSI is collected and it is greater than previous
Y
GAUGE
10 s
float
-1000~1000
-
max(RrhRssiMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1022
Chapter 2 Counter Description Name
Unit
Description
RrhRssiCurr
dBm
The most recent collected RSSI values for each RRH path
RrhRssiTot
mW*1 0^12
RrhRssiCnt
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is updated by the recently collected RSSI value
Y
GAUGE
10 s
float
-1000~1000
-
max(RrhRssiCurr)
The cumulated RSSI linear values for each RRH path
This counter is cumulated by the RSSI when it is collected
Y
GAUGE
10 s
float
3.4*10^38~3 .4*10^38
-
-
count
The cumulated collection count of RrhRssiAvg
This counter is cumulated by 1 when RrhRssiAvg is collected
Y
GAUGE
10 s
int
0~21474836 47
-
-
RrhRssidBmAvg
dBm
The average values of RSSI dBm for each RRH path
This counter is calculated when measurement period comes.
Y
SI
10 s
float
-1000~1000
RrhRssidBmT ot/RrhRssidB mCnt
sum(RrhRssidBmT ot)/sum(RrhRssidB mCnt)
RrhRssidBmTot
dBm
The cumulated RSSI dBm values for each RRH path
This counter is cumulated by the RSSI when it is collected
Y
SI
10 s
float
3.4*10^38~3 .4*10^38
-
-
RrhRssidBmCnt
count
The cumulated collection count of RrhRssidBmAvg
This counter is cumulated by 1 when RrhRssidBmAvg is collected
Y
SI
10 s
int
0~21474836 47
-
-
maximum value
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1023
Chapter 2 Counter Description
RA This section provides statistics on the Random Access (RA) Preamble. These statistics items are described in the following tables.
Random Access Preambles This section provides statistics on the number of the High-Speed Monitoring result and the RACH preamble. For High Speed Monitoring, it estimates the moving speed of the terminals within the cell and counts the terminals where the speed is determined as high. Also, it collects the number of detected Dedicated Preambles, Contention-based Group A Preambles, and Contentionbased Group B Preambles, then collects the average per second of the detected preambles. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
HighSpeedMonit oring
count
The number of UEs which are monitored for moving speed
None
Y
CC
5.12 s
int
0~2147483647
-
-
NoOfHighSpeed
count
The number of high speed UEs which are monitored
None
Y
CC
5.12 s
int
0~2147483647
-
-
DedicatedPream bles
count
The cumulated number of dedicated preambles among the periodically
This counter is cumulated by 1 when a
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1024
Chapter 2 Counter Description Name
Unit
Description
Trigger
collected RACH preambles.
dedicated preamble is received to the eNB.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DedicatedPream blesAssignFail
count
The number of failures to get dedicated preamble allocation after requesting the dedicated preamble from the RRC to the MAC
None
Y
CC
event
int
0~2147483647
-
-
RandomlySelecte dPreamblesLow
count
The cumulated number of the preambles belonging to Group A among the detected contention based preambles
This counter is cumulated by 1 when a Group A preamble is received to the eNB.
Y
CC
5.12 s
int
0~2147483647
-
-
RandomlySelecte dPreamblesHigh
count
The cumulated number of the preambles belonging to Group B among the detected contention based preambles
This counter is cumulated by 1 when a Group B preamble is received to the eNB.
Y
CC
5.12 s
int
0~2147483647
-
-
RACHUsageAvg
count
The average of RACH use rates that were collected during the collection interval.
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
0~3.4*10^38
RACHUsag eTot/RACH UsageCnt
sum(RACHUsage Tot)/sum(RACHU sageCnt)
RACHUsageTot
count
The cumulated number of RACHUsage
This counter is cumulated the number of detected preamble by second
-
SI
5.12 s
float
0~3.4*10^38
-
-
RACHUsageCnt
count
The collection count of
This counter is
-
SI
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1025
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
RACHUsage
cumulated by 1 when the RACHUsage is collected
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RACH Usage This section provides statistics on the RACH Usage for each cell. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PreambleSent1
count
Count (COUNT/CC) when the number of RACH preamble sent is 1
Y
CC
event
int
0~2147483647
-
-
PreambleSent2
count
Count (COUNT/CC) when the number of RACH preamble sent is 2
Y
CC
event
int
0~2147483647
-
-
PreambleSent3
count
Count (COUNT/CC) when the number of RACH preamble sent is 3
Y
CC
event
int
0~2147483647
-
-
PreambleSent4
count
Count (COUNT/CC) when the number of RACH preamble sent is 4
Y
CC
event
int
0~2147483647
-
-
PreambleSent5
count
Count (COUNT/CC) when the number of RACH preamble sent is 5
Y
CC
event
int
0~2147483647
-
-
PreambleSent6
count
Count (COUNT/CC) when the number of RACH preamble sent is 6
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1026
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PreambleSent7
count
Count (COUNT/CC) when the number of RACH preamble sent is 7
Y
CC
event
int
0~2147483647
-
-
PreambleSent8
count
Count (COUNT/CC) when the number of RACH preamble sent is 8
Y
CC
event
int
0~2147483647
-
-
PreambleSent9
count
Count (COUNT/CC) when the number of RACH preamble sent is 9
Y
CC
event
int
0~2147483647
-
-
RACHContention
%
Ratio of RACH contention occurrence
Y
SI
event
float
0~100
RACHConte ntionTot/RA CHContentio nCnt*100
sum(RACHContenti onTot)/sum(RACH ContentionCnt)*100
RACHContentionT ot
count
Cumulative RachContention
Y
SI
event
int
0~2147483647
-
-
RACHContentionC nt
count
Collection count of RACHContention
Y
SI
event
int
0~2147483647
-
-
RACHReportsRcv Num
count
Count when rachReport is received
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1027
Chapter 2 Counter Description
HARQ This section provides statistics on the DL/UL transmission for HARQ. These statistics items are described in the following tables.
Transmission BLER This section provides statistics on the each HARQ transmission for PDSCH/PUSCH and the Block Error Rate (BLER) information. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLResidualBl erRetrans0
%
The calculated value of PDSCH BLER for the initial transmission during the collection interval. BLER is the failure rate for the initial transmission and is a ratio of the number of times the first re-transmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(DLTransmissionRe trans1/DLTransmis sionRetrans0)*100
(sum(DLTransmission Retrans1)/sum(DLTran smissionRetrans0))*10 0
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1028
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
was carried out to the number of times the initial transmission was carried out. DLResidualBl erRetrans1
%
The number of PDSCH BLER for the first HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(DLTransmissionRe trans2/DLTransmis sionRetrans1)*100
(sum(DLTransmission Retrans2)/sum(DLTran smissionRetrans1))*10 0
DLResidualBl erRetrans2
%
The number of PDSCH BLER for the second HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(DLTransmissionRe trans3/DLTransmis sionRetrans2)*100
(sum(DLTransmission Retrans3)/sum(DLTran smissionRetrans2))*10 0
DLResidualBl erRetrans3
%
The number of PDSCH BLER for the third HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(DLTransmissionNa ckedRetrans3/DLTr ansmissionRetrans 3)*100
(sum(DLTransmission NackedRetrans3)/sum( DLTransmissionRetran s3))*100
ULResidualBl erRetrans0
%
The number of PUSCH BLER for the initial HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans1/ULTransmis sionRetrans0)*100
(sum(ULTransmission Retrans1)/sum(ULTran smissionRetrans0))*10 0
ULResidualBl erRetrans1
%
The number of PUSCH BLER for the first HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans2/ULTransmis sionRetrans1)*100
(sum(ULTransmission Retrans2)/sum(ULTran smissionRetrans1))*10 0
ULResidualBl erRetrans2
%
The number of PUSCH BLER for
This counter is calculated
Y
OW
Period
float
0~100
(ULTransmissionRe trans3/ULTransmis
(sum(ULTransmission Retrans3)/sum(ULTran
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1029
Chapter 2 Counter Description Name
Unit
Description
Trigger
the second HARQ retransmission
when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula sionRetrans2)*100
Hourly, Daily, Monthly Formula smissionRetrans2))*10 0
ULResidualBl erRetrans3
%
The number of PUSCH BLER for the third HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionNa ckedRetrans27/UL TransmissionRetra ns3)*100
(sum(ULTransmission NackedRetrans27)/su m(ULTransmissionRetr ans3))*100
ULResidualBl erRetrans4
%
The number of PUSCH BLER for the fourth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans5/ULTransmis sionRetrans4)*100
(sum(ULTransmission Retrans5)/sum(ULTran smissionRetrans4))*10 0
ULResidualBl erRetrans5
%
The number of PUSCH BLER for the fifth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans6/ULTransmis sionRetrans5)*100
(sum(ULTransmission Retrans6)/sum(ULTran smissionRetrans5))*10 0
ULResidualBl erRetrans6
%
The number of PUSCH BLER for the sixth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans7/ULTransmis sionRetrans6)*100
(sum(ULTransmission Retrans7)/sum(ULTran smissionRetrans6))*10 0
ULResidualBl erRetrans7
%
The number of PUSCH BLER for the seventh HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans8/ULTransmis sionRetrans7)*100
(sum(ULTransmission Retrans8)/sum(ULTran smissionRetrans7))*10 0
ULResidualBl erRetrans8
%
The number of PUSCH BLER for the eighth HARQ retransmission
This counter is calculated when measurement
Y
OW
Period
float
0~100
(ULTransmissionRe trans9/ULTransmis sionRetrans8)*100
(sum(ULTransmission Retrans9)/sum(ULTran smissionRetrans8))*10 0
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1030
Chapter 2 Counter Description Name
Unit
Description
ULResidualBl erRetrans9
%
The number of PUSCH BLER for the ninth HARQ retransmission
ULResidualBl erRetrans10
%
ULResidualBl erRetrans11
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans10/ULTransmi ssionRetrans9)*100
(sum(ULTransmission Retrans10)/sum(ULTra nsmissionRetrans9))*1 00
The number of PUSCH BLER for the tenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans11/ULTransmi ssionRetrans10)*10 0
(sum(ULTransmission Retrans11)/sum(ULTra nsmissionRetrans10))* 100
%
The number of PUSCH BLER for the eleventh HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans12/ULTransmi ssionRetrans11)*10 0
(sum(ULTransmission Retrans12)/sum(ULTra nsmissionRetrans11))* 100
ULResidualBl erRetrans12
%
The number of PUSCH BLER for the twelfth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans13/ULTransmi ssionRetrans12)*10 0
(sum(ULTransmission Retrans13)/sum(ULTra nsmissionRetrans12))* 100
ULResidualBl erRetrans13
%
The number of PUSCH BLER for the thirteenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans14/ULTransmi ssionRetrans13)*10 0
(sum(ULTransmission Retrans14)/sum(ULTra nsmissionRetrans13))* 100
ULResidualBl erRetrans14
%
The number of PUSCH BLER for the fourteenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans15/ULTransmi ssionRetrans14)*10 0
(sum(ULTransmission Retrans15)/sum(ULTra nsmissionRetrans14))* 100
ULResidualBl
%
The number of
This counter
Y
OW
Period
float
0~100
(ULTransmissionRe
(sum(ULTransmission
period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1031
Chapter 2 Counter Description Name
Unit
erRetrans15
Description
Trigger
PUSCH BLER for the fifteenth HARQ retransmission
is calculated when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula trans16/ULTransmi ssionRetrans15)*10 0
Hourly, Daily, Monthly Formula Retrans16)/sum(ULTra nsmissionRetrans15))* 100
ULResidualBl erRetrans16
%
The number of PUSCH BLER for the sixteenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans17/ULTransmi ssionRetrans16)*10 0
(sum(ULTransmission Retrans17)/sum(ULTra nsmissionRetrans16))* 100
ULResidualBl erRetrans17
%
The number of PUSCH BLER for the seventeenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans18/ULTransmi ssionRetrans17)*10 0
(sum(ULTransmission Retrans18)/sum(ULTra nsmissionRetrans17))* 100
ULResidualBl erRetrans18
%
The number of PUSCH BLER for the eighteenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans19/ULTransmi ssionRetrans18)*10 0
(sum(ULTransmission Retrans19)/sum(ULTra nsmissionRetrans18))* 100
ULResidualBl erRetrans19
%
The number of PUSCH BLER for the nineteenth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans20/ULTransmi ssionRetrans19)*10 0
(sum(ULTransmission Retrans20)/sum(ULTra nsmissionRetrans19))* 100
ULResidualBl erRetrans20
%
The number of PUSCH BLER for the twentieth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans21/ULTransmi ssionRetrans20)*10 0
(sum(ULTransmission Retrans21)/sum(ULTra nsmissionRetrans20))* 100
ULResidualBl erRetrans21
%
The number of PUSCH BLER for the twenty first
This counter is calculated when
Y
OW
Period
float
0~100
(ULTransmissionRe trans22/ULTransmi ssionRetrans21)*10
(sum(ULTransmission Retrans22)/sum(ULTra nsmissionRetrans21))*
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1032
Chapter 2 Counter Description Name
Unit
Description
Trigger
HARQ retransmission
measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula 0
Hourly, Daily, Monthly Formula 100
ULResidualBl erRetrans22
%
The number of PUSCH BLER for the twenty second HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans23/ULTransmi ssionRetrans22)*10 0
(sum(ULTransmission Retrans23)/sum(ULTra nsmissionRetrans22))* 100
ULResidualBl erRetrans23
%
The number of PUSCH BLER for the twenty third HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans24/ULTransmi ssionRetrans23)*10 0
(sum(ULTransmission Retrans24)/sum(ULTra nsmissionRetrans23))* 100
ULResidualBl erRetrans24
%
The number of PUSCH BLER for the twenty fourth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans25/ULTransmi ssionRetrans24)*10 0
(sum(ULTransmission Retrans25)/sum(ULTra nsmissionRetrans24))* 100
ULResidualBl erRetrans25
%
The number of PUSCH BLER for the twenty fifth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans26/ULTransmi ssionRetrans25)*10 0
(sum(ULTransmission Retrans26)/sum(ULTra nsmissionRetrans25))* 100
ULResidualBl erRetrans26
%
The number of PUSCH BLER for the twenty sixth HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionRe trans27/ULTransmi ssionRetrans26)*10 0
(sum(ULTransmission Retrans27)/sum(ULTra nsmissionRetrans26))* 100
ULResidualBl erRetrans27
%
The number of PUSCH BLER for the twenty seventh HARQ retransmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ULTransmissionNa ckedRetrans27/UL TransmissionRetra ns27)*100
(sum(ULTransmission NackedRetrans27)/su m(ULTransmissionRetr ans27))*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1033
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmissi onRetrans0
count
The cumulated number of initial PDSCH HARQ transmissions
This counter is cumulated by 1 when the initial PDSCH HARQ transmissions occurs
Y
CC
5.12 s
int
0~2147483647
-
-
DLTransmissi onRetrans1
count
The cumulated number of first PDSCH HARQ retransmissions
This counter is cumulated by 1 when the first PDSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
DLTransmissi onRetrans2
count
The cumulated number of second PDSCH HARQ retransmissions
This counter is cumulated by 1 when the second PDSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
DLTransmissi onRetrans3
count
The cumulated number of third PDSCH HARQ retransmissions
This counter is cumulated by 1 when the third PDSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
DLTransmissi onNackedRetr ans3
count
The cumulated of third PDSCH HARQ retransmission failures
This counter is cumulated by 1 when an NAK occurs
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1034
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
after maximum PDSCH HARQ retransmission. ULTransmissi onRetrans0
count
The cumulated number of initial PUSCH HARQ transmissions
This counter is cumulated by 1 when the initial PUSCH HARQ transmissions occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans1
count
The cumulated number of first PUSCH HARQ retransmissions
This counter is cumulated by 1 when the first PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans2
count
The cumulated number of second PUSCH HARQ retransmissions
This counter is cumulated by 1 when the second PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans3
count
The cumulated number of third PUSCH HARQ retransmissions
This counter is cumulated by 1 when the third PUSCH HARQ retransmissio
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1035
Chapter 2 Counter Description Name
Unit
Description
ULTransmissi onRetrans4
count
The cumulated number of fourth PUSCH HARQ retransmissions
ULTransmissi onRetrans5
count
ULTransmissi onRetrans6
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated by 1 when the fourth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
The cumulated number of fifth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the fifth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
count
The cumulated number of sixth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the sixth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans7
count
The cumulated number of seventh PUSCH HARQ retransmissions
This counter is cumulated by 1 when the seventh PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans8
count
The cumulated number of eighth PUSCH HARQ
This counter is cumulated by 1 when the
Y
CC
5.12 s
int
0~2147483647
-
-
ns occurs
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1036
Chapter 2 Counter Description Name
Unit
Description
Trigger
retransmissions
eighth PUSCH HARQ retransmissio ns occurs
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULTransmissi onRetrans9
count
The cumulated number of ninth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the ninth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans10
count
The cumulated number of tenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the tenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans11
count
The cumulated number of eleventh PUSCH HARQ retransmissions
This counter is cumulated by 1 when the eleventh PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans12
count
The cumulated number of twelfth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twelfth PUSCH HARQ
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1037
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
retransmissio ns occurs ULTransmissi onRetrans13
count
The cumulated number of thirteenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the thirteenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans14
count
The cumulated number of fourteenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the fourteenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans15
count
The cumulated number of fifteenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the fifteenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans16
count
The cumulated number of sixteenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the sixteenth PUSCH HARQ retransmissio
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1038
Chapter 2 Counter Description Name
Unit
Description
ULTransmissi onRetrans17
count
The cumulated number of seventeenth PUSCH HARQ retransmissions
ULTransmissi onRetrans18
count
ULTransmissi onRetrans19
ULTransmissi onRetrans20
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated by 1 when the seventeenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
The cumulated number of eighteenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the eighteenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
count
The cumulated number of nineteenth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the nineteenth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
count
The cumulated number of twentieth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twentieth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ns occurs
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1039
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULTransmissi onRetrans21
count
The cumulated number of twenty first PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twenty first PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans22
count
The cumulated number of twenty second PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twenty second PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans23
count
The cumulated number of twenty third PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twenty third PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans24
count
The cumulated number of twenty fourth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twenty fourth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi
count
The cumulated
This counter
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1040
Chapter 2 Counter Description Name
Unit
onRetrans25
Description
Trigger
number of twenty fifth PUSCH HARQ retransmissions
is cumulated by 1 when the twenty fifth PUSCH HARQ retransmissio ns occurs
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULTransmissi onRetrans26
count
The cumulated number of twenty sixth PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twenty sixth PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onRetrans27
count
The cumulated number of twenty seventh PUSCH HARQ retransmissions
This counter is cumulated by 1 when the twenty seventh PUSCH HARQ retransmissio ns occurs
Y
CC
5.12 s
int
0~2147483647
-
-
ULTransmissi onNackedRetr ans27
count
The cumulated number of more than twenty seventh PUSCH HARQ retransmissions and failed to transmit
This counter is cumulated by 1 when an NAK occurs after maximum PUSCH HARQ retransmission.
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1041
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLResidualBl erRetransMin
count
The minimum value of DLResidualRetrans 0~DLResidualRetra ns3
This counter is updated by the minimum value among DlResidual_R etrans0~DlRe sidual_Retran s3
Y
OW
Period
int
0~2147483647
-
min(DLResidualBlerRe transMin)
DLResidualBl erRetransMax
count
The maximum value of DLResidualRetrans 0~DLResidualRetra ns3
This counter is updated by the maximum value among DlResidual_R etrans0~DlRe sidual_Retran s3
Y
OW
Period
int
0~2147483647
-
max(DLResidualBlerR etransMax)
DLResidualBl erRetransAvg
ratio
The average value of DLResidualRetrans 0~DLResidualRetra ns3
This counter is updated by the average value among DlResidual_R etrans0~DlRe sidual_Retran s3
Y
OW
Period
float
0~3.4*10 ^38
(DLTransmissionRe trans1+DLTransmis sionRetrans2+DLTr ansmissionRetrans 3)/DLTransmission Retrans0
(sum(DLTransmission Retrans1)+sum(DLTra nsmissionRetrans2)+s um(DLTransmissionRe trans3))/sum(DLTrans missionRetrans0)
ULResidualBl erRetransMin
count
The minimum value of ULResidualRetrans 0~ULResidualRetra ns27
This counter is updated by the minimum value among UlResidual_R etrans0~UlRe sidual_Retran s3
Y
OW
Period
int
0~2147483647
-
min(ULResidualBlerRe transMin)
ULResidualBl
count
The maximum value
This counter
Y
OW
Period
int
0~2147483647
-
max(ULResidualBlerR
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1042
Chapter 2 Counter Description Name
Unit
erRetransMax
ULResidualBl erRetransAvg
ratio
Description
Trigger
of ULResidualRetrans 0~ULResidualRetra ns27
is updated by the maximum value among UlResidual_R etrans0~UlRe sidual_Retran s3
The average value of ULResidualRetrans 0~ULResidualRetra ns27
This counter is updated by the average value among UlResidual_R etrans0~UlRe sidual_Retran s3
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula etransMax)
Y
OW
Period
float
0~3.4*10^38
(ULTransmissionRe trans1+ULTransmis sionRetrans2+ULTr ansmissionRetrans 3+ULTransmission Retrans4+ULTrans missionRetrans5+U LTransmissionRetr ans6+ULTransmiss ionRetrans7+ULTra nsmissionRetrans8 +ULTransmissionR etrans9+ULTransmi ssionRetrans10+UL TransmissionRetra ns11+ULTransmiss ionRetrans12+ULTr ansmissionRetrans 13+ULTransmissio nRetrans14+ULTra nsmissionRetrans1 5+ULTransmission Retrans16+ULTran smissionRetrans17 +ULTransmissionR etrans18+ULTrans missionRetrans19+ ULTransmissionRet
(sum(ULTransmission Retrans1)+sum(ULTra nsmissionRetrans2)+s um(ULTransmissionRe trans3)+sum(ULTrans missionRetrans4)+sum (ULTransmissionRetra ns5)+sum(ULTransmis sionRetrans6)+sum(UL TransmissionRetrans7) +sum(ULTransmission Retrans8)+sum(ULTra nsmissionRetrans9)+s um(ULTransmissionRe trans10)+sum(ULTrans missionRetrans11)+su m(ULTransmissionRetr ans12)+sum(ULTrans missionRetrans13)+su m(ULTransmissionRetr ans14)+sum(ULTrans missionRetrans15)+su m(ULTransmissionRetr ans16)+sum(ULTrans missionRetrans17)+su m(ULTransmissionRetr ans18)+sum(ULTrans missionRetrans19)+su 1043
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula rans20+ULTransmi ssionRetrans21+UL TransmissionRetra ns22+ULTransmiss ionRetrans23+ULTr ansmissionRetrans 24+ULTransmissio nRetrans25+ULTra nsmissionRetrans2 6+ULTransmission Retrans27)/ULTran smissionRetrans0
Hourly, Daily, Monthly Formula m(ULTransmissionRetr ans20)+sum(ULTrans missionRetrans21)+su m(ULTransmissionRetr ans22)+sum(ULTrans missionRetrans23)+su m(ULTransmissionRetr ans24)+sum(ULTrans missionRetrans25)+su m(ULTransmissionRetr ans26)+sum(ULTrans missionRetrans27))/su m(ULTransmissionRetr ans0)
DLResidualBl erRetransNak
%
The calculated value of PDSCH BELR for HARQ NAK
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
DLTransmissionNa ckedRetrans3/DLTr ansmissionRetrans 0*100
sum(DLTransmissionN ackedRetrans3)/sum(D LTransmissionRetrans 0)*100
ULResidualBl erRetransNak
%
The calculated value of PUSCH BELR for HARQ NAK
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
ULTransmissionNa ckedRetrans27/UL TransmissionRetra ns0*100
sum(ULTransmissionN ackedRetrans27)/sum( ULTransmissionRetran s0)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1044
Chapter 2 Counter Description
AMC MIMO This section provides statistics on the Block Error Rate (BLER) information for each layer for PUSCH/PDSCH. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBlerPerL ayer
%
The BLER for the PDSCH at each layer during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerPer LayerTot/Pdsc hBlerPerLayer Cnt*100
sum(PdschBlerPerLayerT ot)/sum(PdschBlerPerLay erCnt)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1045
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of times transmission failed to the number of times transmission succeeded. PdschBlerPerL ayerTot
count
The cumulated number of failed transmission for the periodically collected PDSCH transmission.
This counter is cumulated by 1 when a PDSCH error is collected per each layer.
-
CC
5.12 s
int
0~3.4*10^38
-
-
PdschBlerPerL ayerCnt
count
The cumulated number of successful transmission for the periodically collected PDSCH transmission.
This counter is cumulated by 1 when the PDSCH is transmitted per each layer.
-
CC
5.12 s
int
0~214748364 7
-
-
PuschBlerPerL ayer
%
The BLER for PUSCH at each layer during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerPer LayerTot/Pusc hBlerPerLayer Cnt*100
sum(PuschBlerPerLayerT ot)/sum(PuschBlerPerLay erCnt)*100
PuschBlerPerL ayerTot
count
The cumulated number of failed
This counter is cumulated by 1
-
CC
5.12 s
int
0~3.4*10^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1046
Chapter 2 Counter Description Name
PuschBlerPerL ayerCnt
Unit
count
Description
Trigger
transmission for the periodically collected PUSCH transmission.
when a PUSCH error is collected per each layer.
The cumulated number of successful transmission for the periodically collected PUSCH transmission.
This counter is cumulated by 1 when PUSCH is transmitted per each layer.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
-
CC
5.12 s
int
0~214748364 7
-
-
1047
Chapter 2 Counter Description
MCS This section provides statistics on the PUSCH’s Block Error Rate (BLER), the number of allocated PRBs and the number of transmissions for each MCS. For the PDSCH, it collects the Block Error Rate (BLER) and the number of allocated PRBs. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs0
%
The BLER for the PDSCH at MCS0 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s0Tot/Pdsch BlerMcs0Cnt *100
sum(PdschBlerMc s0Tot)/sum(Pdsch BlerMcs0Cnt)*100
PdschBler Mcs1
%
The BLER for the PDSCH at MCS1 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s1Tot/Pdsch BlerMcs1Cnt *100
sum(PdschBlerMc s1Tot)/sum(Pdsch BlerMcs1Cnt)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1048
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
transmission failed to the number of times transmission succeeded. PdschBler Mcs2
%
The BLER for the PDSCH at MCS2 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s2Tot/Pdsch BlerMcs2Cnt *100
sum(PdschBlerMc s2Tot)/sum(Pdsch BlerMcs2Cnt)*100
PdschBler Mcs3
%
The BLER for the PDSCH at MCS3 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s3Tot/Pdsch BlerMcs3Cnt *100
sum(PdschBlerMc s3Tot)/sum(Pdsch BlerMcs3Cnt)*100
PdschBler Mcs4
%
The BLER for the PDSCH at MCS4 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s4Tot/Pdsch BlerMcs4Cnt *100
sum(PdschBlerMc s4Tot)/sum(Pdsch BlerMcs4Cnt)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1049
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs5
%
The BLER for the PDSCH at MCS5 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s5Tot/Pdsch BlerMcs5Cnt *100
sum(PdschBlerMc s5Tot)/sum(Pdsch BlerMcs5Cnt)*100
PdschBler Mcs6
%
The BLER for the PDSCH at MCS6 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s6Tot/Pdsch BlerMcs6Cnt *100
sum(PdschBlerMc s6Tot)/sum(Pdsch BlerMcs6Cnt)*100
PdschBler Mcs7
%
The BLER for the PDSCH at MCS7 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s7Tot/Pdsch BlerMcs7Cnt *100
sum(PdschBlerMc s7Tot)/sum(Pdsch BlerMcs7Cnt)*100
PdschBler Mcs8
%
The BLER for the PDSCH at MCS8 during the collection interval. BLER is the failure rate in
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s8Tot/Pdsch BlerMcs8Cnt
sum(PdschBlerMc s8Tot)/sum(Pdsch BlerMcs8Cnt)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1050
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula *100
Hourly, Daily, Monthly Formula
relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded. PdschBler Mcs9
%
The BLER for the PDSCH at MCS9 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s9Tot/Pdsch BlerMcs9Cnt *100
sum(PdschBlerMc s9Tot)/sum(Pdsch BlerMcs9Cnt)*100
PdschBler Mcs10
%
The BLER for the PDSCH at MCS10 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s10Tot/Pdsc hBlerMcs10 Cnt*100
sum(PdschBlerMc s10Tot)/sum(Pdsc hBlerMcs10Cnt)*1 00
PdschBler Mcs11
%
The BLER for the PDSCH at MCS11 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s11Tot/Pdsc hBlerMcs11 Cnt*100
sum(PdschBlerMc s11Tot)/sum(Pdsc hBlerMcs11Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1051
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of times transmission succeeded. PdschBler Mcs12
%
The BLER for the PDSCH at MCS12 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s12Tot/Pdsc hBlerMcs12 Cnt*100
sum(PdschBlerMc s12Tot)/sum(Pdsc hBlerMcs12Cnt)*1 00
PdschBler Mcs13
%
The BLER for the PDSCH at MCS13 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s13Tot/Pdsc hBlerMcs13 Cnt*100
sum(PdschBlerMc s13Tot)/sum(Pdsc hBlerMcs13Cnt)*1 00
PdschBler Mcs14
%
The BLER for the PDSCH at MCS14 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s14Tot/Pdsc hBlerMcs14 Cnt*100
sum(PdschBlerMc s14Tot)/sum(Pdsc hBlerMcs14Cnt)*1 00
PdschBler
%
The BLER for the PDSCH
This counter is calculated
Y
OW
Period
float
0~100
PdschBlerMc
sum(PdschBlerMc
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1052
Chapter 2 Counter Description Name
Unit
Mcs15
Description
Trigger
at MCS15 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula s15Tot/Pdsc hBlerMcs15 Cnt*100
Hourly, Daily, Monthly Formula s15Tot)/sum(Pdsc hBlerMcs15Cnt)*1 00
PdschBler Mcs16
%
The BLER for the PDSCH at MCS16 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s16Tot/Pdsc hBlerMcs16 Cnt*100
sum(PdschBlerMc s16Tot)/sum(Pdsc hBlerMcs16Cnt)*1 00
PdschBler Mcs17
%
The BLER for the PDSCH at MCS17 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s17Tot/Pdsc hBlerMcs17 Cnt*100
sum(PdschBlerMc s17Tot)/sum(Pdsc hBlerMcs17Cnt)*1 00
PdschBler Mcs18
%
The BLER for the PDSCH at MCS18 during the collection interval. BLER is the failure rate in relation to transmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s18Tot/Pdsc hBlerMcs18 Cnt*100
sum(PdschBlerMc s18Tot)/sum(Pdsc hBlerMcs18Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1053
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
and is a ratio of the number of times transmission failed to the number of times transmission succeeded. PdschBler Mcs19
%
The BLER for the PDSCH at MCS19 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s19Tot/Pdsc hBlerMcs19 Cnt*100
sum(PdschBlerMc s19Tot)/sum(Pdsc hBlerMcs19Cnt)*1 00
PdschBler Mcs20
%
The BLER for the PDSCH at MCS20 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s20Tot/Pdsc hBlerMcs20 Cnt*100
sum(PdschBlerMc s20Tot)/sum(Pdsc hBlerMcs20Cnt)*1 00
PdschBler Mcs21
%
The BLER for the PDSCH at MCS21 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s21Tot/Pdsc hBlerMcs21 Cnt*100
sum(PdschBlerMc s21Tot)/sum(Pdsc hBlerMcs21Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1054
Chapter 2 Counter Description Name
Unit
PdschBler Mcs22
%
PdschBler Mcs23
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The BLER for the PDSCH at MCS22 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s22Tot/Pdsc hBlerMcs22 Cnt*100
sum(PdschBlerMc s22Tot)/sum(Pdsc hBlerMcs22Cnt)*1 00
%
The BLER for the PDSCH at MCS23 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s23Tot/Pdsc hBlerMcs23 Cnt*100
sum(PdschBlerMc s23Tot)/sum(Pdsc hBlerMcs23Cnt)*1 00
PdschBler Mcs24
%
The BLER for the PDSCH at MCS24 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s24Tot/Pdsc hBlerMcs24 Cnt*100
sum(PdschBlerMc s24Tot)/sum(Pdsc hBlerMcs24Cnt)*1 00
PdschBler Mcs25
%
The BLER for the PDSCH at MCS25 during the
This counter is calculated when measurement period
Y
OW
Period
float
0~100
PdschBlerMc s25Tot/Pdsc
sum(PdschBlerMc s25Tot)/sum(Pdsc
transmission succeeded.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1055
Chapter 2 Counter Description Name
Unit
Description
Trigger
collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula hBlerMcs25 Cnt*100
Hourly, Daily, Monthly Formula hBlerMcs25Cnt)*1 00
PdschBler Mcs26
%
The BLER for the PDSCH at MCS26 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s26Tot/Pdsc hBlerMcs26 Cnt*100
sum(PdschBlerMc s26Tot)/sum(Pdsc hBlerMcs26Cnt)*1 00
PdschBler Mcs27
%
The BLER for the PDSCH at MCS27 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s27Tot/Pdsc hBlerMcs27 Cnt*100
sum(PdschBlerMc s27Tot)/sum(Pdsc hBlerMcs27Cnt)*1 00
PdschBler Mcs28
%
The BLER for the PDSCH at MCS28 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s28Tot/Pdsc hBlerMcs28 Cnt*100
sum(PdschBlerMc s28Tot)/sum(Pdsc hBlerMcs28Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1056
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of times transmission failed to the number of times transmission succeeded. PdschBler Mcs29
%
The BLER for the PDSCH at MCS29 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s29Tot/Pdsc hBlerMcs29 Cnt*100
sum(PdschBlerMc s29Tot)/sum(Pdsc hBlerMcs29Cnt)*1 00
PdschBler Mcs30
%
The BLER for the PDSCH at MCS30 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s30Tot/Pdsc hBlerMcs30 Cnt*100
sum(PdschBlerMc s30Tot)/sum(Pdsc hBlerMcs30Cnt)*1 00
PdschBler Mcs31
%
The BLER for the PDSCH at MCS31 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PdschBlerMc s31Tot/Pdsc hBlerMcs31 Cnt*100
sum(PdschBlerMc s31Tot)/sum(Pdsc hBlerMcs31Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1057
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs0Tot
count
The cumulated number of times PDSCH transmission failed at MCS0. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS0's PDSCH transmission.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs1Tot
count
The cumulated number of times PDSCH transmission failed at MCS1. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS1's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs2Tot
count
The cumulated number of times PDSCH transmission failed at MCS2. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS2's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs3Tot
count
The cumulated number of times PDSCH transmission failed at MCS3. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS3's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs4Tot
count
The cumulated number of times PDSCH transmission failed at MCS4. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS4's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs5Tot
count
The cumulated number of times PDSCH transmission failed at
This counter is cumulated by 1 when an error in MCS5's PDSCH transmission is
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1058
Chapter 2 Counter Description Name
Unit
Description
Trigger
MCS5. For this counter, statistics are collected periodically.
collected.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs6Tot
count
The cumulated number of times PDSCH transmission failed at MCS6. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS6's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs7Tot
count
The cumulated number of times PDSCH transmission failed at MCS7. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS7's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs8Tot
count
The cumulated number of times PDSCH transmission failed at MCS8. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS8's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs9Tot
count
The cumulated number of times PDSCH transmission failed at MCS9. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS9's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs10Tot
count
The cumulated number of times PDSCH transmission failed at MCS10. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS10's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1059
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs11Tot
count
The cumulated number of times PDSCH transmission failed at MCS11. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS11's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs12Tot
count
The cumulated number of times PDSCH transmission failed at MCS12. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS12's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs13Tot
count
The cumulated number of times PDSCH transmission failed at MCS13. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS13's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs14Tot
count
The cumulated number of times PDSCH transmission failed at MCS14. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS14's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs15Tot
count
The cumulated number of times PDSCH transmission failed at MCS15. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS15's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs16Tot
count
The cumulated number of times PDSCH transmission failed at
This counter is cumulated by 1 when an error in MCS16's PDSCH transmission is
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1060
Chapter 2 Counter Description Name
Unit
Description
Trigger
MCS16. For this counter, statistics are collected periodically.
collected.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs17Tot
count
The cumulated number of times PDSCH transmission failed at MCS17. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS17's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs18Tot
count
The cumulated number of times PDSCH transmission failed at MCS18. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS18's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs19Tot
count
The cumulated number of times PDSCH transmission failed at MCS19. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS19's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs20Tot
count
The cumulated number of times PDSCH transmission failed at MCS20. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS20's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs21Tot
count
The cumulated number of times PDSCH transmission failed at MCS21. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS21's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1061
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs22Tot
count
The cumulated number of times PDSCH transmission failed at MCS22. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS22's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs23Tot
count
The cumulated number of times PDSCH transmission failed at MCS23. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS23's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs24Tot
count
The cumulated number of times PDSCH transmission failed at MCS24. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS24's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs25Tot
count
The cumulated number of times PDSCH transmission failed at MCS25. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS25's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs26Tot
count
The cumulated number of times PDSCH transmission failed at MCS26. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS26's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs27Tot
count
The cumulated number of times PDSCH transmission failed at
This counter is cumulated by 1 when an error in MCS27's PDSCH transmission is
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1062
Chapter 2 Counter Description Name
Unit
Description
Trigger
MCS27. For this counter, statistics are collected periodically.
collected.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs28Tot
count
The cumulated number of times PDSCH transmission failed at MCS28. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS28's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs29Tot
count
The cumulated number of times PDSCH transmission failed at MCS29. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS29's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs30Tot
count
The cumulated number of times PDSCH transmission failed at MCS30. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS30's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs31Tot
count
The cumulated number of times PDSCH transmission failed at MCS31. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error in MCS31's PDSCH transmission is collected.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PdschBler Mcs0Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS0. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS0's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1063
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs1Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS1. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS1's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs2Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS2. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS2's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs3Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS3. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS3's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs4Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS4. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS4's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs5Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS5. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS5's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs6Cnt
count
The cumulated number of times PDSCH transmission succeeded
This counter is cumulated by 1 when MCS6's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1064
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
at MCS6. For this counter, statistics are collected periodically. PdschBler Mcs7Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS7. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS7's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs8Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS8. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS8's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs9Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS9. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS9's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs10Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS10. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS10's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs11Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS11. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS11's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1065
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs12Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS12. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS12's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs13Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS13. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS13's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs14Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS14. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS14's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs15Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS15. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS15's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs16Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS16. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS16's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs17Cnt
count
The cumulated number of times PDSCH transmission succeeded
This counter is cumulated by 1 when MCS17's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1066
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
at MCS17. For this counter, statistics are collected periodically. PdschBler Mcs18Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS18. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS18's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs19Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS19. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS19's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs20Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS20. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS20's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs21Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS21. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS21's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs22Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS22. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS22's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1067
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdschBler Mcs23Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS23. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS23's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs24Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS24. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS24's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs25Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS25. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS25's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs26Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS26. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS26's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs27Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS27. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS27's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs28Cnt
count
The cumulated number of times PDSCH transmission succeeded
This counter is cumulated by 1 when MCS28's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1068
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
at MCS28. For this counter, statistics are collected periodically. PdschBler Mcs29Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS29. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS29's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs30Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS30. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS30's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PdschBler Mcs31Cnt
count
The cumulated number of times PDSCH transmission succeeded at MCS31. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS31's PDSCH is transmitted
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs0
%
The BLER for PUSCH at MCS0 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s0Tot/Pusch BlerMcs0Cnt *100
sum(PuschBlerMc s0Tot)/sum(Pusch BlerMcs0Cnt)*100
PuschBler Mcs1
%
The BLER for PUSCH at MCS1 during the
This counter is calculated when measurement period
Y
OW
Period
float
0~100
PuschBlerMc s1Tot/Pusch
sum(PuschBlerMc s1Tot)/sum(Pusch
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1069
Chapter 2 Counter Description Name
Unit
Description
Trigger
collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula BlerMcs1Cnt *100
Hourly, Daily, Monthly Formula BlerMcs1Cnt)*100
PuschBler Mcs2
%
The BLER for PUSCH at MCS2 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s2Tot/Pusch BlerMcs2Cnt *100
sum(PuschBlerMc s2Tot)/sum(Pusch BlerMcs2Cnt)*100
PuschBler Mcs3
%
The BLER for PUSCH at MCS3 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s3Tot/Pusch BlerMcs3Cnt *100
sum(PuschBlerMc s3Tot)/sum(Pusch BlerMcs3Cnt)*100
PuschBler Mcs4
%
The BLER for PUSCH at MCS4 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s4Tot/Pusch BlerMcs4Cnt *100
sum(PuschBlerMc s4Tot)/sum(Pusch BlerMcs4Cnt)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1070
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of times transmission failed to the number of times transmission succeeded. PuschBler Mcs5
%
The BLER for PUSCH at MCS5 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s5Tot/Pusch BlerMcs5Cnt *100
sum(PuschBlerMc s5Tot)/sum(Pusch BlerMcs5Cnt)*100
PuschBler Mcs6
%
The BLER for PUSCH at MCS6 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s6Tot/Pusch BlerMcs6Cnt *100
sum(PuschBlerMc s6Tot)/sum(Pusch BlerMcs6Cnt)*100
PuschBler Mcs7
%
The BLER for PUSCH at MCS7 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s7Tot/Pusch BlerMcs7Cnt *100
sum(PuschBlerMc s7Tot)/sum(Pusch BlerMcs7Cnt)*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1071
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PuschBler Mcs8
%
The BLER for PUSCH at MCS8 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s8Tot/Pusch BlerMcs8Cnt *100
sum(PuschBlerMc s8Tot)/sum(Pusch BlerMcs8Cnt)*100
PuschBler Mcs9
%
The BLER for PUSCH at MCS9 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s9Tot/Pusch BlerMcs9Cnt *100
sum(PuschBlerMc s9Tot)/sum(Pusch BlerMcs9Cnt)*100
PuschBler Mcs10
%
The BLER for PUSCH at MCS10 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s10Tot/Pusc hBlerMcs10 Cnt*100
sum(PuschBlerMc s10Tot)/sum(Pusc hBlerMcs10Cnt)*1 00
PuschBler Mcs11
%
The BLER for PUSCH at MCS11 during the collection interval. BLER is the failure rate in
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s11Tot/Pusc hBlerMcs11
sum(PuschBlerMc s11Tot)/sum(Pusc hBlerMcs11Cnt)*1
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1072
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula Cnt*100
Hourly, Daily, Monthly Formula 00
relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded. PuschBler Mcs12
%
The BLER for PUSCH at MCS12 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s12Tot/Pusc hBlerMcs12 Cnt*100
sum(PuschBlerMc s12Tot)/sum(Pusc hBlerMcs12Cnt)*1 00
PuschBler Mcs13
%
The BLER for PUSCH at MCS13 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s13Tot/Pusc hBlerMcs13 Cnt*100
sum(PuschBlerMc s13Tot)/sum(Pusc hBlerMcs13Cnt)*1 00
PuschBler Mcs14
%
The BLER for PUSCH at MCS14 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s14Tot/Pusc hBlerMcs14 Cnt*100
sum(PuschBlerMc s14Tot)/sum(Pusc hBlerMcs14Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1073
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of times transmission succeeded. PuschBler Mcs15
%
The BLER for PUSCH at MCS15 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s15Tot/Pusc hBlerMcs15 Cnt*100
sum(PuschBlerMc s15Tot)/sum(Pusc hBlerMcs15Cnt)*1 00
PuschBler Mcs16
%
The BLER for PUSCH at MCS16 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s16Tot/Pusc hBlerMcs16 Cnt*100
sum(PuschBlerMc s16Tot)/sum(Pusc hBlerMcs16Cnt)*1 00
PuschBler Mcs17
%
The BLER for PUSCH at MCS17 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s17Tot/Pusc hBlerMcs17 Cnt*100
sum(PuschBlerMc s17Tot)/sum(Pusc hBlerMcs17Cnt)*1 00
PuschBler
%
The BLER for PUSCH at
This counter is calculated
Y
OW
Period
float
0~100
PuschBlerMc
sum(PuschBlerMc
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1074
Chapter 2 Counter Description Name
Unit
Mcs18
Description
Trigger
MCS18 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula s18Tot/Pusc hBlerMcs18 Cnt*100
Hourly, Daily, Monthly Formula s18Tot)/sum(Pusc hBlerMcs18Cnt)*1 00
PuschBler Mcs19
%
The BLER for PUSCH at MCS19 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s19Tot/Pusc hBlerMcs19 Cnt*100
sum(PuschBlerMc s19Tot)/sum(Pusc hBlerMcs19Cnt)*1 00
PuschBler Mcs20
%
The BLER for PUSCH at MCS20 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s20Tot/Pusc hBlerMcs20 Cnt*100
sum(PuschBlerMc s20Tot)/sum(Pusc hBlerMcs20Cnt)*1 00
PuschBler Mcs21
%
The BLER for PUSCH at MCS21 during the collection interval. BLER is the failure rate in relation to transmission
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s21Tot/Pusc hBlerMcs21 Cnt*100
sum(PuschBlerMc s21Tot)/sum(Pusc hBlerMcs21Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1075
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
and is a ratio of the number of times transmission failed to the number of times transmission succeeded. PuschBler Mcs22
%
The BLER for PUSCH at MCS22 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s22Tot/Pusc hBlerMcs22 Cnt*100
sum(PuschBlerMc s22Tot)/sum(Pusc hBlerMcs22Cnt)*1 00
PuschBler Mcs23
%
The BLER for PUSCH at MCS23 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s23Tot/Pusc hBlerMcs23 Cnt*100
sum(PuschBlerMc s23Tot)/sum(Pusc hBlerMcs23Cnt)*1 00
PuschBler Mcs24
%
The BLER for PUSCH at MCS24 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s24Tot/Pusc hBlerMcs24 Cnt*100
sum(PuschBlerMc s24Tot)/sum(Pusc hBlerMcs24Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1076
Chapter 2 Counter Description Name
Unit
PuschBler Mcs25
%
PuschBler Mcs26
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The BLER for PUSCH at MCS25 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s25Tot/Pusc hBlerMcs25 Cnt*100
sum(PuschBlerMc s25Tot)/sum(Pusc hBlerMcs25Cnt)*1 00
%
The BLER for PUSCH at MCS26 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s26Tot/Pusc hBlerMcs26 Cnt*100
sum(PuschBlerMc s26Tot)/sum(Pusc hBlerMcs26Cnt)*1 00
PuschBler Mcs27
%
The BLER for PUSCH at MCS27 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s27Tot/Pusc hBlerMcs27 Cnt*100
sum(PuschBlerMc s27Tot)/sum(Pusc hBlerMcs27Cnt)*1 00
PuschBler Mcs28
%
The BLER for PUSCH at MCS28 during the
This counter is calculated when measurement period
Y
OW
Period
float
0~100
PuschBlerMc s28Tot/Pusc
sum(PuschBlerMc s28Tot)/sum(Pusc
transmission succeeded.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1077
Chapter 2 Counter Description Name
Unit
Description
Trigger
collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula hBlerMcs28 Cnt*100
Hourly, Daily, Monthly Formula hBlerMcs28Cnt)*1 00
PuschBler Mcs29
%
The BLER for PUSCH at MCS29 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s29Tot/Pusc hBlerMcs29 Cnt*100
sum(PuschBlerMc s29Tot)/sum(Pusc hBlerMcs29Cnt)*1 00
PuschBler Mcs30
%
The BLER for PUSCH at MCS30 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the number of times transmission failed to the number of times transmission succeeded.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s30Tot/Pusc hBlerMcs30 Cnt*100
sum(PuschBlerMc s30Tot)/sum(Pusc hBlerMcs30Cnt)*1 00
PuschBler Mcs31
%
The BLER for PUSCH at MCS31 during the collection interval. BLER is the failure rate in relation to transmission and is a ratio of the
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
PuschBlerMc s31Tot/Pusc hBlerMcs31 Cnt*100
sum(PuschBlerMc s31Tot)/sum(Pusc hBlerMcs31Cnt)*1 00
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1078
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
number of times transmission failed to the number of times transmission succeeded. PuschBler Mcs0Tot
count
The cumulated number of times PUSCH transmission failed at MCS0. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS0's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs1Tot
count
The cumulated number of times PUSCH transmission failed at MCS1. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS1's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs2Tot
count
The cumulated number of times PUSCH transmission failed at MCS2. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS2's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs3Tot
count
The cumulated number of times PUSCH transmission failed at MCS3. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS3's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs4Tot
count
The cumulated number of times PUSCH transmission failed at MCS4. For this counter, statistics are collected
This counter is cumulated by 1 when an error occurs in MCS4's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1079
Chapter 2 Counter Description Name
Unit
PuschBler Mcs5Tot
count
PuschBler Mcs6Tot
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The cumulated number of times PUSCH transmission failed at MCS5. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS5's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
count
The cumulated number of times PUSCH transmission failed at MCS6. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS6's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs7Tot
count
The cumulated number of times PUSCH transmission failed at MCS7. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS7's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs8Tot
count
The cumulated number of times PUSCH transmission failed at MCS8. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS8's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs9Tot
count
The cumulated number of times PUSCH transmission failed at MCS9. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS9's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler
count
The cumulated number of
This counter is cumulated by
-
CC
5.12 s
float
0~3.4*1
-
-
periodically.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1080
Chapter 2 Counter Description Name
Unit
Mcs10Tot
Description
Trigger
times PUSCH transmission failed at MCS10. For this counter, statistics are collected periodically.
1 when an error occurs in MCS10's PUSCH reception.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
0^38
PuschBler Mcs11Tot
count
The cumulated number of times PUSCH transmission failed at MCS11. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS11's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs12Tot
count
The cumulated number of times PUSCH transmission failed at MCS12. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS12's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs13Tot
count
The cumulated number of times PUSCH transmission failed at MCS13. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS13's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs14Tot
count
The cumulated number of times PUSCH transmission failed at MCS14. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS14's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs15Tot
count
The cumulated number of times PUSCH transmission failed at MCS15. For this counter,
This counter is cumulated by 1 when an error occurs in MCS15's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1081
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
statistics are collected periodically. PuschBler Mcs16Tot
count
The cumulated number of times PUSCH transmission failed at MCS16. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS16's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs17Tot
count
The cumulated number of times PUSCH transmission failed at MCS17. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS17's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs18Tot
count
The cumulated number of times PUSCH transmission failed at MCS18. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS18's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs19Tot
count
The cumulated number of times PUSCH transmission failed at MCS19. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS19's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs20Tot
count
The cumulated number of times PUSCH transmission failed at MCS20. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS20's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1082
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PuschBler Mcs21Tot
count
The cumulated number of times PUSCH transmission failed at MCS21. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS21's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs22Tot
count
The cumulated number of times PUSCH transmission failed at MCS22. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS22's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs23Tot
count
The cumulated number of times PUSCH transmission failed at MCS23. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS23's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs24Tot
count
The cumulated number of times PUSCH transmission failed at MCS24. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS24's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs25Tot
count
The cumulated number of times PUSCH transmission failed at MCS25. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS25's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs26Tot
count
The cumulated number of times PUSCH transmission failed at
This counter is cumulated by 1 when an error occurs in MCS26's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1083
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
MCS26. For this counter, statistics are collected periodically. PuschBler Mcs27Tot
count
The cumulated number of times PUSCH transmission failed at MCS27. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS27's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs28Tot
count
The cumulated number of times PUSCH transmission failed at MCS28. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS28's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs29Tot
count
The cumulated number of times PUSCH transmission failed at MCS29. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS29's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs30Tot
count
The cumulated number of times PUSCH transmission failed at MCS30. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS30's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
PuschBler Mcs31Tot
count
The cumulated number of times PUSCH transmission failed at MCS31. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when an error occurs in MCS31's PUSCH reception.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1084
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PuschBler Mcs0Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS0. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS0's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs1Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS1. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS1's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs2Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS2. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS2's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs3Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS3. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS3's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs4Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS4. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS4's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs5Cnt
count
The cumulated number of times PUSCH transmission succeeded
This counter is cumulated by 1 when MCS5's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1085
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
at MCS5. For this counter, statistics are collected periodically. PuschBler Mcs6Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS6. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS6's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs7Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS7. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS7's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs8Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS8. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS8's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs9Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS9. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS9's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs10Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS10. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS10's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1086
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PuschBler Mcs11Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS11. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS11's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs12Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS12. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS12's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs13Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS13. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS13's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs14Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS14. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS14's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs15Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS15. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS15's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs16Cnt
count
The cumulated number of times PUSCH transmission succeeded
This counter is cumulated by 1 when MCS16's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1087
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
at MCS16. For this counter, statistics are collected periodically. PuschBler Mcs17Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS17. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS17's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs18Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS18. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS18's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs19Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS19. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS19's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs20Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS20. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS20's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs21Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS21. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS21's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1088
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PuschBler Mcs22Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS22. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS22's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs23Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS23. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS23's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs24Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS24. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS24's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs25Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS25. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS25's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs26Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS26. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS26's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs27Cnt
count
The cumulated number of times PUSCH transmission succeeded
This counter is cumulated by 1 when MCS27's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1089
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
at MCS27. For this counter, statistics are collected periodically. PuschBler Mcs28Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS28. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS28's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs29Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS29. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS29's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs30Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS30. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS30's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
PuschBler Mcs31Cnt
count
The cumulated number of times PUSCH transmission succeeded at MCS31. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS31's PUSCH transmission occurs.
-
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs0
count
The cumulated number of times PUSCH was received at MCS0. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS0 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1090
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULReceive dMcs1
count
The cumulated number of times PUSCH was received at MCS1. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS1 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs2
count
The cumulated number of times PUSCH was received at MCS2. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS2 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs3
count
The cumulated number of times PUSCH was received at MCS3. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS3 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs4
count
The cumulated number of times PUSCH was received at MCS4. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS4 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs5
count
The cumulated number of times PUSCH was received at MCS5. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS5 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs6
count
The cumulated number of times PUSCH was received at MCS6. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS6 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs7
count
The cumulated number of times PUSCH was
This counter is cumulated by 1 when MCS7 PUSCH is
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1091
Chapter 2 Counter Description Name
Unit
Description
Trigger
received at MCS7. For this counter, statistics are collected periodically.
received.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULReceive dMcs8
count
The cumulated number of times PUSCH was received at MCS8. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS8 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs9
count
The cumulated number of times PUSCH was received at MCS9. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS9 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs10
count
The cumulated number of times PUSCH was received at MCS10. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS10 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs11
count
The cumulated number of times PUSCH was received at MCS11. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS11 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs12
count
The cumulated number of times PUSCH was received at MCS12. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS12 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs13
count
The cumulated number of times PUSCH was received at MCS13. For this counter, statistics are
This counter is cumulated by 1 when MCS13 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1092
Chapter 2 Counter Description Name
Unit
ULReceive dMcs14
count
ULReceive dMcs15
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The cumulated number of times PUSCH was received at MCS14. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS14 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
count
The cumulated number of times PUSCH was received at MCS15. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS15 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs16
count
The cumulated number of times PUSCH was received at MCS16. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS16 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs17
count
The cumulated number of times PUSCH was received at MCS17. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS17 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs18
count
The cumulated number of times PUSCH was received at MCS18. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS18 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs19
count
The cumulated number of times PUSCH was received at MCS19. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS19 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive
count
The cumulated number of
This counter is cumulated by
Y
CC
5.12 s
int
0~21474
-
-
collected periodically.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1093
Chapter 2 Counter Description Name
Unit
dMcs20
Description
Trigger
times PUSCH was received at MCS20. For this counter, statistics are collected periodically.
1 when MCS20 PUSCH is received.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
ULReceive dMcs21
count
The cumulated number of times PUSCH was received at MCS21. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS21 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs22
count
The cumulated number of times PUSCH was received at MCS22. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS22 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs23
count
The cumulated number of times PUSCH was received at MCS23. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS23 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs24
count
The cumulated number of times PUSCH was received at MCS24. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS24 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs25
count
The cumulated number of times PUSCH was received at MCS25. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS25 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs26
count
The cumulated number of times PUSCH was received at MCS26. For
This counter is cumulated by 1 when MCS26 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1094
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
this counter, statistics are collected periodically. ULReceive dMcs27
count
The cumulated number of times PUSCH was received at MCS27. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS27 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs28
count
The cumulated number of times PUSCH was received at MCS28. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS28 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs29
count
The cumulated number of times PUSCH was received at MCS29. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS29 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs30
count
The cumulated number of times PUSCH was received at MCS30. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS30 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
ULReceive dMcs31
count
The cumulated number of times PUSCH was received at MCS31. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when MCS31 PUSCH is received.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs0
count
The cumulated number of PRBs assigned to PDSCH MCS 0
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS0's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul
count
The cumulated number of
This counter is cumulated by
Y
CC
5.12 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1095
Chapter 2 Counter Description Name
Unit
erMcs1
Description
Trigger
PRBs assigned to PDSCH MCS 1
the size of PRB when the PRB is allocated to transmit MCS1's PDSCH
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
DLSchedul erMcs2
count
The cumulated number of PRBs assigned to PDSCH MCS 2
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS2's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs3
count
The cumulated number of PRBs assigned to PDSCH MCS 3
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS3's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs4
count
The cumulated number of PRBs assigned to PDSCH MCS 4
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS4's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs5
count
The cumulated number of PRBs assigned to PDSCH MCS 5
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS5's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs6
count
The cumulated number of PRBs assigned to PDSCH MCS 6
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS6's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs7
count
The cumulated number of PRBs assigned to PDSCH MCS 7
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS7's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs8
count
The cumulated number of PRBs assigned to PDSCH MCS 8
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS8's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1096
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLSchedul erMcs9
count
The cumulated number of PRBs assigned to PDSCH MCS 9
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS9's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs10
count
The cumulated number of PRBs assigned to PDSCH MCS 10
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS10's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs11
count
The cumulated number of PRBs assigned to PDSCH MCS 11
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS11's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs12
count
The cumulated number of PRBs assigned to PDSCH MCS 12
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS12's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs13
count
The cumulated number of PRBs assigned to PDSCH MCS 13
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS13's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs14
count
The cumulated number of PRBs assigned to PDSCH MCS 14
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS14's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs15
count
The cumulated number of PRBs assigned to PDSCH MCS 15
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS15's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs16
count
The cumulated number of PRBs assigned to PDSCH MCS 16
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS16's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1097
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLSchedul erMcs17
count
The cumulated number of PRBs assigned to PDSCH MCS 17
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS17's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs18
count
The cumulated number of PRBs assigned to PDSCH MCS 18
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS18's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs19
count
The cumulated number of PRBs assigned to PDSCH MCS 19
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS19's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs20
count
The cumulated number of PRBs assigned to PDSCH MCS 20
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS20's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs21
count
The cumulated number of PRBs assigned to PDSCH MCS 21
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS21's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs22
count
The cumulated number of PRBs assigned to PDSCH MCS 22
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS22's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs23
count
The cumulated number of PRBs assigned to PDSCH MCS 23
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS23's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs24
count
The cumulated number of PRBs assigned to PDSCH MCS 24
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS24's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1098
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLSchedul erMcs25
count
The cumulated number of PRBs assigned to PDSCH MCS 25
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS25's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs26
count
The cumulated number of PRBs assigned to PDSCH MCS 26
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS26's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs27
count
The cumulated number of PRBs assigned to PDSCH MCS 27
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS27's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs28
count
The cumulated number of PRBs assigned to PDSCH MCS 28
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS28's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs29
count
The cumulated number of PRBs assigned to PDSCH MCS 29
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS29's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs30
count
The cumulated number of PRBs assigned to PDSCH MCS 30
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS30's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
DLSchedul erMcs31
count
The cumulated number of PRBs assigned to PDSCH MCS 31
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS31's PDSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs0
count
The cumulated number of PRBs assigned to PUSCH MCS 0
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS0's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1099
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULSchedul erMcs1
count
The cumulated number of PRBs assigned to PUSCH MCS 1
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS1's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs2
count
The cumulated number of PRBs assigned to PUSCH MCS 2
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS2's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs3
count
The cumulated number of PRBs assigned to PUSCH MCS 3
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS3's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs4
count
The cumulated number of PRBs assigned to PUSCH MCS 4
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS4's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs5
count
The cumulated number of PRBs assigned to PUSCH MCS 5
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS5's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs6
count
The cumulated number of PRBs assigned to PUSCH MCS 6
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS6's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs7
count
The cumulated number of PRBs assigned to PUSCH MCS 7
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS7's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs8
count
The cumulated number of PRBs assigned to PUSCH MCS 8
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS8's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1100
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULSchedul erMcs9
count
The cumulated number of PRBs assigned to PUSCH MCS 9
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS9's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs10
count
The cumulated number of PRBs assigned to PUSCH MCS 10
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS10's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs11
count
The cumulated number of PRBs assigned to PUSCH MCS 11
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS11's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs12
count
The cumulated number of PRBs assigned to PUSCH MCS 12
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS12's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs13
count
The cumulated number of PRBs assigned to PUSCH MCS 13
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS13's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs14
count
The cumulated number of PRBs assigned to PUSCH MCS 14
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS14's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs15
count
The cumulated number of PRBs assigned to PUSCH MCS 15
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS15's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs16
count
The cumulated number of PRBs assigned to PUSCH MCS 16
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS16's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1101
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULSchedul erMcs17
count
The cumulated number of PRBs assigned to PUSCH MCS 17
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS17's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs18
count
The cumulated number of PRBs assigned to PUSCH MCS 18
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS18's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs19
count
The cumulated number of PRBs assigned to PUSCH MCS 19
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS19's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs20
count
The cumulated number of PRBs assigned to PUSCH MCS 20
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS20's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs21
count
The cumulated number of PRBs assigned to PUSCH MCS 21
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS21's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs22
count
The cumulated number of PRBs assigned to PUSCH MCS 22
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS22's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs23
count
The cumulated number of PRBs assigned to PUSCH MCS 23
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS23's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs24
count
The cumulated number of PRBs assigned to PUSCH MCS 24
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS24's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1102
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULSchedul erMcs25
count
The cumulated number of PRBs assigned to PUSCH MCS 25
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS25's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs26
count
The cumulated number of PRBs assigned to PUSCH MCS 26
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS26's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs27
count
The cumulated number of PRBs assigned to PUSCH MCS 27
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS27's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs28
count
The cumulated number of PRBs assigned to PUSCH MCS 28
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS28's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs29
count
The cumulated number of PRBs assigned to PUSCH MCS 29
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS29's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs30
count
The cumulated number of PRBs assigned to PUSCH MCS 30
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS30's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
ULSchedul erMcs31
count
The cumulated number of PRBs assigned to PUSCH MCS 31
This counter is cumulated by the size of PRB when the PRB is allocated to transmit MCS31's PUSCH
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1103
Chapter 2 Counter Description
DL MCS This section provides statistics on the transmission counts per MCS/layer/Codeword for PDSCH. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 streams 3: 3 streams 4: 4 streams
codeword
Codeword (Transport block count) 0: First transport block 1: Second transport block
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmittedMcs0
count
The cumulated number of times that MCS 0 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS0's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1
count
The cumulated number of times that MCS 1 PDSCH is
This counter is cumulated by 1 when MCS1's PDSCH is
Y
CC
5.12 s
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1104
Chapter 2 Counter Description Name
Unit
Description
Trigger
transmitted per Layer/Codeword
transmitted per layer/codeword.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmittedMcs2
count
The cumulated number of times that MCS 2 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS2's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs3
count
The cumulated number of times that MCS 3 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS3's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs4
count
The cumulated number of times that MCS 4 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS4's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs5
count
The cumulated number of times that MCS 5 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS5's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs6
count
The cumulated number of times that MCS 6 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS6's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs7
count
The cumulated number of times that MCS 7 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS7's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1105
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmittedMcs8
count
The cumulated number of times that MCS 8 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS8's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs9
count
The cumulated number of times that MCS 9 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS9's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 0
count
The cumulated number of times that MCS 10 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS10's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 1
count
The cumulated number of times that MCS 11 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS11's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 2
count
The cumulated number of times that MCS 12 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS12's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 3
count
The cumulated number of times that MCS 13 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS13's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 4
count
The cumulated number of times that
This counter is cumulated by 1 when
Y
CC
5.12 s
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1106
Chapter 2 Counter Description Name
Unit
Description
Trigger
MCS 14 PDSCH is transmitted per Layer/Codeword
MCS14's PDSCH is transmitted per layer/codeword.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmittedMcs1 5
count
The cumulated number of times that MCS 15 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS15's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 6
count
The cumulated number of times that MCS 16 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS16's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 7
count
The cumulated number of times that MCS 17 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS17's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 8
count
The cumulated number of times that MCS 18 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS18's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs1 9
count
The cumulated number of times that MCS 19 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS19's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 0
count
The cumulated number of times that MCS 20 PDSCH is transmitted per
This counter is cumulated by 1 when MCS20's PDSCH is transmitted per
Y
CC
5.12 s
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1107
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmittedMcs2 1
count
Layer/Codeword
layer/codeword.
The cumulated number of times that MCS 21 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS21's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 2
count
The cumulated number of times that MCS 22 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS22's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 3
count
The cumulated number of times that MCS 23 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS23's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 4
count
The cumulated number of times that MCS 24 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS24's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 5
count
The cumulated number of times that MCS 25 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS25's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 6
count
The cumulated number of times that MCS 26 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS26's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2
count
The cumulated
This counter is
Y
CC
5.12 s
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1108
Chapter 2 Counter Description Name
Unit
7
Description
Trigger
number of times that MCS 27 PDSCH is transmitted per Layer/Codeword
cumulated by 1 when MCS27's PDSCH is transmitted per layer/codeword.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
DLTransmittedMcs2 8
count
The cumulated number of times that MCS 28 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS28's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs2 9
count
The cumulated number of times that MCS 29 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS29's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs3 0
count
The cumulated number of times that MCS 30 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS30's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
DLTransmittedMcs3 1
count
The cumulated number of times that MCS 31 PDSCH is transmitted per Layer/Codeword
This counter is cumulated by 1 when MCS31's PDSCH is transmitted per layer/codeword.
Y
CC
5.12 s
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1109
Chapter 2 Counter Description
DL LAYER This section provides statistics on the transmission counts per layer for PDSCH. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLTransmitte dLayer
count
The cumulated number of transmission per layer for PDSCH
This counter is cumulated by 1 when the PDSCH is transmitted per layer
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1110
Chapter 2 Counter Description
DL Wideband CQI This section provides statistics on the CQI report information per layer/codeword for the UE. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
codeword
Codeword (the number of Transport block) 0: first transport block 1: second transport block
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI0
count
The cumulated number of times CQI0 and CQI Erase were received for each layer/codeword. For this counter, statistics are collected periodically.
This counter is cumulated by 1 when CQI0 or CQI Erase is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1111
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI1
count
The cumulated number that CQI 1 is received per layer/codeword
This counter is cumulated by 1 when CQI1 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI2
count
The cumulated number that CQI 2 is received per layer/codeword
This counter is cumulated by 1 when CQI2 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI3
count
The cumulated number that CQI 3 is received per layer/codeword
This counter is cumulated by 1 when CQI3 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI4
count
The cumulated number that CQI 4 is received per layer/codeword
This counter is cumulated by 1 when CQI4 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI5
count
The cumulated number that CQI 5 is received per layer/codeword
This counter is cumulated by 1 when CQI5 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI6
count
The cumulated number that CQI 6 is received per layer/codeword
This counter is cumulated by 1 when CQI6 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI7
count
The cumulated number that CQI 7 is received
This counter is cumulated by 1
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1112
Chapter 2 Counter Description Name
Unit
Description
Trigger
per layer/codeword
when CQI7 is received per layer/codeword.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI8
count
The cumulated number that CQI 8 is received per layer/codeword
This counter is cumulated by 1 when CQI8 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI9
count
The cumulated number that CQI 9 is received per layer/codeword
This counter is cumulated by 1 when CQI9 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 0
count
The cumulated number that CQI 10 is received per layer/codeword
This counter is cumulated by 1 when CQI10 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 1
count
The cumulated number that CQI 11 is received per layer/codeword
This counter is cumulated by 1 when CQI11 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 2
count
The cumulated number that CQI 12 is received per layer/codeword
This counter is cumulated by 1 when CQI12 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 3
count
The cumulated number that CQI 13 is received per layer/codeword
This counter is cumulated by 1 when CQI13 is received per
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1113
Chapter 2 Counter Description Name
Unit
Description
DLReceivedCQI1 4
count
The cumulated number that CQI 14 is received per layer/codeword
DLReceivedCQI1 5
count
DLReceivedCQIM in
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
This counter is cumulated by 1 when CQI14 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
The cumulated number that CQI 15 is received per layer/codeword
This counter is cumulated by 1 when CQI15 is received per layer/codeword.
Y
CC
5.12 s
int
0~21474 83647
-
-
CQI
The minimum value of DLReceivedCQI0~DLR eceivedCQ15
This counter is updated when the DLReceivedCQI Min is smaller than the previous value.
Y
OW
Period
int
0~15
-
min(DLReceivedCQIM in)
DLReceivedCQIM ax
CQI
The maximum value of DLReceivedCQI0~DLR eceivedCQ15
This counter is updated when the DLReceivedCQI Max is greater than the previous value.
Y
OW
Period
int
0~15
-
max(DLReceivedCQI Max)
DLReceivedCQIA vg
CQI
The average value of DLReceivedCQI0~DLR eceivedCQ15
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~15
(0*DLReceivedC QI0+1*DLReceiv edCQI1+2*DLRe ceivedCQI2+3*D LReceivedCQI3+ 4*DLReceivedC QI4+5*DLReceiv edCQI5+6*DLRe
(0*sum(DLReceivedC QI0)+1*sum(DLReceiv edCQI1)+2*sum(DLR eceivedCQI2)+3*sum( DLReceivedCQI3)+4* sum(DLReceivedCQI4 )+5*sum(DLReceived CQI5)+6*sum(DLRece
layer/codeword.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1114
Chapter 2 Counter Description Name
Unit
Description
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula ceivedCQI6+7*D LReceivedCQI7+ 8*DLReceivedC QI8+9*DLReceiv edCQI9+10*DLR eceivedCQI10+1 1*DLReceivedC QI11+12*DLRec eivedCQI12+13* DLReceivedCQI 13+14*DLReceiv edCQI14+15*DL ReceivedCQI15) /(DLReceivedCQ I0+DLReceivedC QI1+DLReceived CQI2+DLReceiv edCQI3+DLRece ivedCQI4+DLRe ceivedCQI5+DL ReceivedCQI6+ DLReceivedCQI 7+DLReceivedC QI8+DLReceived CQI9+DLReceiv edCQI10+DLRec eivedCQI11+DL ReceivedCQI12+ DLReceivedCQI 13+DLReceived CQI14+DLRecei vedCQI15)
Hourly, Daily, Monthly Formula ivedCQI6)+7*sum(DL ReceivedCQI7)+8*su m(DLReceivedCQI8)+ 9*sum(DLReceivedC QI9)+10*sum(DLRece ivedCQI10)+11*sum( DLReceivedCQI11)+1 2*sum(DLReceivedC QI12)+13*sum(DLRec eivedCQI13)+14*sum( DLReceivedCQI14)+1 5*sum(DLReceivedC QI15))/(sum(DLReceiv edCQI0)+sum(DLRec eivedCQI1)+sum(DLR eceivedCQI2)+sum(D LReceivedCQI3)+sum (DLReceivedCQI4)+s um(DLReceivedCQI5) +sum(DLReceivedCQI 6)+sum(DLReceivedC QI7)+sum(DLReceive dCQI8)+sum(DLRecei vedCQI9)+sum(DLRe ceivedCQI10)+sum(D LReceivedCQI11)+su m(DLReceivedCQI12) +sum(DLReceivedCQI 13)+sum(DLReceived CQI14)+sum(DLRecei vedCQI15))
1115
Chapter 2 Counter Description
DL PMI This section provides statistics on the number of times that PMI is received for each Layer of UE. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedPMI0
count
The cumulated number that PMI 0 is received
This counter is cumulated by 1 when PMI0 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI1
count
The cumulated number that PMI 1 is received
This counter is cumulated by 1 when PMI1 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI2
count
The cumulated number that PMI 2 is received
This counter is cumulated by 1 when PMI2 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI3
count
The cumulated number that PMI 3 is received
This counter is cumulated by 1 when PMI3 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI4
count
The cumulated
This counter is
Y
CC
5.12 s
int
0~214748364
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1116
Chapter 2 Counter Description Name
Unit
Description
Trigger
number that PMI 4 is received
cumulated by 1 when PMI4 is received
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
7
DLReceivedPMI5
count
The cumulated number that PMI 5 is received
This counter is cumulated by 1 when PMI5 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI6
count
The cumulated number that PMI 6 is received
This counter is cumulated by 1 when PMI6 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI7
count
The cumulated number that PMI 7 is received
This counter is cumulated by 1 when PMI7 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI8
count
The cumulated number that PMI 8 is received
This counter is cumulated by 1 when PMI8 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI9
count
The cumulated number that PMI 9 is received
This counter is cumulated by 1 when PMI9 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI1 0
count
The cumulated number that PMI 10 is received
This counter is cumulated by 1 when PMI10 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI1 1
count
The cumulated number that PMI 11 is received
This counter is cumulated by 1 when PMI11 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1117
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedPMI1 2
count
The cumulated number that PMI 12 is received
This counter is cumulated by 1 when PMI12 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI1 3
count
The cumulated number that PMI 13 is received
This counter is cumulated by 1 when PMI13 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI1 4
count
The cumulated number that PMI 14 is received
This counter is cumulated by 1 when PMI14 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
DLReceivedPMI1 5
count
The cumulated number that PMI 15 is received
This counter is cumulated by 1 when PMI15 is received
Y
CC
5.12 s
int
0~214748364 7
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1118
Chapter 2 Counter Description
DL RI This section provides statistics on the UE’s RI report information in the MAC Layer. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceiv edRI0
count
Reserved
None
Y
CC
5.12 s
int
0~2147483647
-
-
DLReceiv edRI1
count
The cumulated number that RI 1 is received
This counter is cumulated by 1 when RI1 is received
Y
CC
5.12 s
int
0~2147483647
-
-
DLReceiv edRI2
count
The cumulated number that RI 2 is received
This counter is cumulated by 1 when RI2 is received
Y
CC
5.12 s
int
0~2147483647
-
-
DLReceiv edRI3
count
The cumulated number that RI 3 is received
This counter is cumulated by 1 when RI3 is received
Y
CC
5.12 s
int
0~2147483647
-
-
DLReceiv edRI4
count
The cumulated number that RI 4 is received
This counter is cumulated by 1 when RI4 is
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1119
Chapter 2 Counter Description Name
Unit
Description
DLReceiv edRIAvg
RI
The average value of DLReceivedRI0~DLRec eivedRI4
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
OW
Period
int
0~4
(0*DLReceived RI0+1*DLRece ivedRI1+2*DL ReceivedRI2+ 3*DLReceived RI3+4*DLRece ivedRI4)/(DLR eceivedRI0+D LReceivedRI1 +DLReceivedR I2+DLReceive dRI3+DLRecei vedRI4)
(0*sum(DLReceivedRI0 )+1*sum(DLReceivedRI 1)+2*sum(DLReceived RI2)+3*sum(DLReceive dRI3)+4*sum(DLReceiv edRI4))/(sum(DLReceiv edRI0)+sum(DLReceive dRI1)+sum(DLReceived RI2)+sum(DLReceived RI3)+sum(DLReceived RI4))
received This counter is calculated when measurement period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1120
Chapter 2 Counter Description
DL-ACK-NACK-DTX Ratio This section provides statistics on the ACK, NACK, DTX ratio per layer in the MAC Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
codeword
Codeword (the number of Transport block) 0: first transport block 1: second transport block
status
0: ACK, 1: NACK, 2: DTX
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedAckN ackDtxRatio
%
The average value of ACK, NACK, DTX ratio
This counter is calculated when measurem ent period comes.
Y
SI
5.12 s
float
0~100
DLReceivedAckNackDt xRatioTot/DLReceivedA ckNackDtxRatioCnt
sum(DLReceivedAck NackDtxRatioTot)/su m(DLReceivedAckNa ckDtxRatioCnt)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1121
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedAckN ackDtxRatioTot
%
The sum of DlreceivedAckNack DtxRatio in the collection period
This counter is cumulated when Dlreceived AckNackD txRatio is collected
-
SI
5.12 s
float
0~3.4*10^38
-
-
DLReceivedAckN ackDtxRatioCnt
count
The collection count of DlreceivedAckNack DtxRatio
This counter is cumulated by 1 when Dlreceived AckNackD txRatio is collected
-
SI
5.12 s
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1122
Chapter 2 Counter Description
Timing Alignment Timing Alignment This section provides statistics on the TA for each cell. The TA is collected in the unit of 16Ts when the RRC Connection Request message is received from the MAC. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TimeAdvanceSecti on0
count
distance (meter): 0~200, 16TS: from 0 to 2
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on1
count
distance (meter): 201~400, 16TS: from 3 to 5
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on2
count
distance (meter): 401~600, 16TS: from 6 to 7
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on3
count
distance (meter): 601~800, 16TS: from 8 to 10
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on4
count
distance (meter): 801~1000, 16TS: from 11 to 12
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1123
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TimeAdvanceSecti on5
count
distance (meter): 1001~1200, 16TS: from 13 to 15
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on6
count
distance (meter): 1201~1400, 16TS: from 16 to 17
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on7
count
distance (meter): 1401~1600, 16TS: from 18 to 20
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on8
count
distance (meter): 1601~1800, 16TS: from 21 to 22
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on9
count
distance (meter): 1801~2000, 16TS: from 23 to 25
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on10
count
distance (meter): 2001~2500, 16TS: from 26 to 31
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on11
count
distance (meter): 2501~3000, 16TS: from 32 to 38
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on12
count
distance (meter): 3001~3500, 16TS: from 39 to 44
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on13
count
distance (meter): 3501~4000, 16TS: from 45 to 50
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on14
count
distance (meter): 4001~5000, 16TS: from 51 to 63
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on15
count
distance (meter): 5001~6000, 16TS: from 64 to 76
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on16
count
distance (meter): 6001~7000, 16TS: from 77 to 88
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on17
count
distance (meter): 7001~8000, 16TS: from 89 to 101
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti on18
count
distance (meter): 8001~9000, 16TS: from 102 to 114
Y
CC
event
int
0~2147483647
-
-
TimeAdvanceSecti
count
distance (meter): 9001~10000, 16TS:
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1124
Chapter 2 Counter Description Name
Unit
on19 TimeAdvanceSecti on20
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
CC
event
int
0~2147483647
-
-
from 115 to 126 count
distance (meter): 10001~, 16TS: from 127 to 1282
IOT Uplink IOT Level This section provides statistics on the Uplink IOT by nine levels. The IoT dB value is divided into 10 levels for each PRB and the statistics levels are classified as follows. Level 1: Level 2:
IoT < 7 dB 7 <= IoT < 7.25 dB
Level 3: 7.25 <= IoT < 7.5dB Level 4: 7.5 <= IoT < 7.75 dB Level 5: 7.75 <= IoT < 8.25 dB Level 6: 8.25 <= IoT < 8.5 dB Level 7: 8.5 <= IoT < 8.75 dB Level 8: 8.75 <= IoT < 9 dB Level 9:
9 <= IoT
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1125
Chapter 2 Counter Description
Index Name
Description
cNum
Cell Id
LEVEL
IOT Level
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PRB0
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB1
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB2
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB3
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB4
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB5
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB6
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB7
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB8
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB9
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB10
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB11
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB12
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB13
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB14
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB15
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB16
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB17
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB18
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1126
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PRB19
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB20
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB21
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB22
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB23
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB24
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB25
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB26
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB27
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB28
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB29
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB30
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB31
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB32
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB33
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB34
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB35
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB36
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB37
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB38
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB39
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB40
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB41
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB42
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1127
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PRB43
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB44
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB45
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB46
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB47
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB48
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB49
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB50
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB51
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB52
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB53
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB54
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB55
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB56
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB57
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB58
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB59
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB60
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB61
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB62
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB63
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB64
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB65
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB66
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1128
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PRB67
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB68
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB69
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB70
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB71
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB72
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB73
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB74
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB75
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB76
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB77
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB78
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB79
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB80
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB81
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB82
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB83
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB84
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB85
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB86
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB87
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB88
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB89
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB90
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1129
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PRB91
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB92
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB93
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB94
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB95
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB96
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB97
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB98
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
PRB99
count
IOT level count for each PRB
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1130
Chapter 2 Counter Description
Load Balancing Load This section provides statistics on Load information of MLB (Mobility Load Balancing). Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
LoadIndicatorAvg
%
The average load of a cell when overload occurs due to the MLBO operation
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~10 0
LoadIndicat orTot/LoadI ndicatorCnt
sum(LoadIndicatorTot)/ sum(LoadIndicatorCnt)
LoadIndicatorMin
%
The minimum number of LoadIndicatorAvg
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~10 0
-
min(LoadIndicatorMin)
LoadIndicatorMax
%
The maximum number of LoadIndicatorAvg
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~10 0
-
max(LoadIndicatorMax)
LoadIndicatorTot
%
The cumulated number of load when overload occurs due
This counter is collected when transmitting ActiveLbInfoInd message to
Y
GAUGE
5s
float
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1131
Chapter 2 Counter Description Name
Unit
Description
Trigger
to the MLBO operation
the ECCB
Visible
Counter Type
Trigger Type
Data Type
Min/ Max
Granularity Formula
Hourly, Daily, Monthly Formula
LoadIndicatorCnt
count
The collection count of LoadIndicatorAvg
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
int
0~21 4748 3647
-
-
OverloadCount
count
The cumulated number of overload occurrences due to the MLBO operation
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
CC
5s
int
0~21 4748 3647
-
-
MlbDurationAvg
s
The average of the overload period due to the MLBO operation
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~3.4 *10^3 8
MlbDuratio nTot/MlbDu rationCnt
sum(MlbDurationTot)/s um(MlbDurationCnt)
MlbDurationMin
s
The minimum number of MlbDurationAvg
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~3.4 *10^3 8
-
min(MlbDurationMin)
MlbDurationMax
s
The minimum number of MlbDurationAvg
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~3.4 *10^3 8
-
max(MlbDurationMax)
MlbDurationTot
s
The cumulated value of the overload period due to the MLBO operation
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
float
0~3.4 *10^3 8
-
-
MlbDurationCnt
count
The collection count of MlbDurationAvg
This counter is collected when transmitting ActiveLbInfoInd message to the ECCB
Y
GAUGE
5s
int
0~21 4748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1132
Chapter 2 Counter Description
Collection Time Figure 595. Collection Time for Load DSP
CSAB
ECCB
PrbUsage
. . .
ActiveLbInd 1
PrbUsage
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
LoadInd, MlbDuration
1133
Chapter 2 Counter Description
Load Balancing Handover This section provides statistics on the handovers that are performed by SON Load Balancing. Index Name
Description
cNum
Cell Id
tcID
Target Cell Id
Step
Load Balancing Handover Triggering Step 1: LBHO within the same group & sector 2: LBHO between different groups but the same sector (the same eNB) 3: LBHO between different sectors
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
MlbNotTriggered_L oadCondition
count
The number of times when there is no candidate neighbor cell that meets the load condition although MLB is triggered (collected only at Step 3)
Y
CC
event
int
0~2147483647
-
-
MlbNotTriggered_ RadioCondition
count
The number of times when there is no candidate UE because radio condition is not met although MLB is triggered (collected only at Step 3)
Y
CC
event
int
0~2147483647
-
-
MlbHOAtt
count
The number of handover attempts when MLB is triggered. For each source cell, the statistics are collected for up to 32 most targeted destination cells (based on highest number of handover
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1134
Chapter 2 Counter Description Name
Unit
MlbHOSucc
count
LbhoCnt LbhoCid
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The number of successful handovers when MLB is triggered
Y
CC
event
int
0~2147483647
-
-
count
Load Balancing handover collection count
-
CC
event
int
0~2147483647
-
-
tcID
tcID of which collection is requested
-
OW
event
int
0~2147483647
-
-
attempts).
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1135
Chapter 2 Counter Description
Idle Load Balancing This section provides statistics on the idle Load Distribution. Index Name
Description
cNum
Cell Id
TargetEarfcnDl
Target Neighbor cell frequency (EARFCN DL)
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UECount
count
Number of UEs with maximum cellReselectionPriority in the carrier selected by the idle UE distribution function during RRC connection release
Y
CC
event
int
0~2147483647
-
-
IdleLbCnt
count
Idle load balancing collection count
-
CC
event
int
0~2147483647
-
-
IdleLbTargetEarfcn DL
Target Earfcn Dl
TargetEarfcnDl requested for collection
-
OW
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1136
Chapter 2 Counter Description
Redirection by Load Balancing This section provides statistics on redirection that are performed by load balancing. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
LBRedirectiontoLT E
count
Number of times that load balancing is redirected to intra-LTE cell
Y
CC
event
int
0~2147483647
-
-
LBRedirectiontoW CDMA
count
Number of times that load balancing is redirected to WCDMA
Y
CC
event
int
0~2147483647
-
-
LBRedirectiontoGS M
count
Number of times that load balancing is redirected to GSM
Y
CC
event
int
0~2147483647
-
-
LBRedirectiontoHR PD
count
Number of times that load balancing is redirected to HRPD
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1137
Chapter 2 Counter Description
Load Histogram This section provides histogram statistics based on cell load information. Index Name
Description
cNum
Cell Id
HistogramBin
Bin index of Histogram
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
LoadBinAvg
%
Average of cell load per each Bin Index
Y
SI
2s
float
0~100
LoadBinTot/Load BinCnt
sum(LoadBinTot)/su m(LoadBinCnt)
LoadBinTot
%
Accumulated value of LoadBinAvg
-
SI
2s
float
0~3.4*10^38
-
-
LoadBinCnt
count
Collection count of LoadBinAvg
Y
SI
2s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1138
Chapter 2 Counter Description
Collection Time Figure 596. Collection Time for Load Histogram DSP
CSAB
ECCB
PrbUsage 1 . . .
LoadHistogram
ActiveLbInd
PrbUsage
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1139
Chapter 2 Counter Description
Message RRC Message This section provides statistics on the RRC Message transmitted/received by the eNB. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotalRrcTx
count
Number of Total RRC Msg transmitted by the eNB
Y
CC
event
int
0~214748 3647
-
-
TotalRrcRx
count
Number of Total RRC Msg received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcCounterCheck
count
Number of RrcCounterCheck Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcCounterCheckRe sponse
count
Number of RrcCounterCheck Response Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcCSFBParameters RequestCDMA2000
count
Number of RrcCSFBParameters RequestCDMA2000 Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcCSFBParameters
count
Number of RrcCSFBParameters
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1140
Chapter 2 Counter Description Name
Unit
ResponseCDMA200 0
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
ResponseCDMA2000 Msg transmitted/received by the eNB
RrcDLInformationTra nsfer
count
Number of RrcDLInformationTransfer Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcHandoverFromE UTRAPreparationRe quest
count
Number of RrcHandoverFromEUTRA PreparationRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcMeasurementRe port
count
Number of RrcMeasurementReport Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcMobilityFromEUT RACommand
count
Number of RrcMobilityFromEUTRA Command Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR econfiguration
count
Number of RrcRRCConnection Reconfiguration Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR econfigurationCompl ete
count
Number of RrcRRCConnection ReconfigurationComplete Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR eestablishment
count
Number of RrcRRCConnection Reestablishment Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR eestablishmentComp lete
count
Number of RrcRRCConnection ReestablishmentComplete Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR eestablishmentRejec t
count
Number of RrcRRCConnection ReestablishmentReject Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR eestablishmentRequ est
count
Number of RrcRRCConnection ReestablishmentRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1141
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RrcRrcConnectionR eject
count
Number of RrcRRCConnectionReject Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR elease
count
Number of RrcRRCConnection Release Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionR equest
count
Number of RrcRRCConnection Request Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionSe tup
count
Number of RrcRRCConnectionSetup Msg transmitted/received by the eN
Y
CC
event
int
0~214748 3647
-
-
RrcRrcConnectionSe tupComplete
count
Number of RrcRRCConnection SetupComplete Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcSecurityModeCo mmand
count
Number of RrcSecurityModeCommand Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcSecurityModeCo mplete
count
Number of RrcSecurityModeComplete Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcSecurityModeFail ure
count
Number of RrcSecurityModeFailure Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcUECapabilityEnq uiry
count
Number of RrcUECapabilityEnquiry Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcUECapabilityInfor mation
count
Number of RrcUECapabilityInformation Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcULHandoverPrep arationTransfer
count
Number of RrcULHandover PreparationTransfer Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcULInformationTra nsfer
count
Number of RrcULInformationTransfer Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcUEInformationRe
count
Number of RrcUEInformationRequest
Y
CC
event
int
0~214748
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1142
Chapter 2 Counter Description Name
Unit
quest
Description
Visible
Counter Type
Trigger Type
Data Type
Msg transmitted/received by the eNB
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
3647
RrcUEInformationRe sponse
count
Number of RrcUEInformation Response Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcProximityIndicatio n
count
Number of RrcProximityIndication Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcMBMSInterestInd ication
count
Number of RrcMBMSInterestIndication Msg transmitted/received by the eNB
Y
CC
event
int
0~214748 3647
-
-
RrcInterFreqRSTDM easurementIndicatio n
count
Number of InterFreqRSTDMeasurementIndication Msg received by the eNB
Y
CC
event
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1143
Chapter 2 Counter Description
S1AP Message This section provides statistics on the S1AP Message transmitted/received from the eNB. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotalS1apTx
count
Number of Total S1AP Msg transmitted by the eNB
Y
CC
event
int
0~21474 83647
-
-
TotalS1apRx
count
Number of Total S1AP Msg received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apCellTrafficTrac e
count
Number of S1apCellTrafficTrace Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apDeactivateTrac e
count
Number of S1apDeactivateTrace Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apDownlinkNAST ransport
count
Number of S1apDownlinkNASTransport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apDownlinkScdm a2000tunneling
count
Number of S1apDownlinkScdma2000 tunneling Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apENBConfigurati onTransfer
count
Number of S1apENBConfiguration Transfer Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apENBConfigurati
count
Number of S1apENBConfiguration
Y
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1144
Chapter 2 Counter Description Name
Unit
onUpdate
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
Update Msg transmitted/received by the eNB
S1apENBConfigurati onUpdateAcknowled ge
count
Number of S1apENBConfiguration UpdateAcknowledge Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apENBConfigurati onUpdateFailure
count
Number of S1apENBConfiguration UpdateFailure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apENBDirectInfor mationTransfer
count
Number of S1apENBDirectInformation Transfer Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apENBStatusTran sfer
count
Number of S1apENBStatusTransfer Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABModifyRe quest
count
Number of S1apERABModifyRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABModifyRe sponse
count
Number of S1apERABModifyResponse Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABRelease Command
count
Number of S1apERABReleaseCommand Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABRelease Response
count
Number of S1apERABReleaseResponse Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABReleaseI ndication
count
Number of S1apERABReleaseIndication Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABSetupRe quest
count
Number of S1apERABSetupRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apERABSetupRe sponse
count
Number of S1apERABSetupResponse Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apErrorIndication
count
Number of S1apErrorIndication Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1145
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1apHandoverCanc el
count
Number of S1apHandoverCancel Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverCanc elAcknowledge
count
Number of S1apHandoverCancelAcknow ledge Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverCom mand
count
Number of S1apHandoverCommand Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverFailur e
count
Number of S1apHandoverFailure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverNotify
count
Number of S1apHandoverNotify Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverPrepa rationFailure
count
Number of S1apHandoverPreparation Failure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverRequ est
count
Number of S1apHandoverRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverRequ estAcknowledge
count
Number of S1apHandoverRequest Acknowledge Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apHandoverRequi red
count
Number of S1apHandoverRequired Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apInitialContextSe tupFailure
count
Number of S1apInitialContextSetup Failure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apInitialContextSe tupRequest
count
Number of S1apInitialContextSetup Request Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apInitialContextSe tupResponse
count
Number of S1apInitialContextSetup Response Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1146
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1apInitialUEMessa ge
count
Number of S1apInitialUEMessage Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apLocationReporti ngControl
count
Number of S1apLocationReporting Control Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apLocationReport FailureIndication
count
Number of S1apLocationReportFailure Indication Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apLocationReport
count
Number of S1apLocationReport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apMMEConfigurat ionTransfer
count
Number of S1apMMEConfiguration Transfer Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apMMEConfigurat ionUpdate
count
Number of S1apMMEConfiguration Update Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apMMEConfigurat ionUpdateAcknowle dge
count
Number of S1apMMEConfiguration UpdateAcknowledge Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apMMEConfigurat ionUpdateFailure
count
Number of S1apMMEConfiguration UpdateFailure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apMMEDirectInfor mationTransfer
count
Number of S1apMMEDirectInformation Transfer Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apMMEStatusTra nsfer
count
Number of S1apMMEStatusTransfer Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apNASNonDeliver yIndication
count
Number of S1apNASNonDelivery Indication Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1147
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1apOverloadStart
count
Number of S1apOverloadStart Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apOverloadStop
count
Number of S1apOverloadStop Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apPaging
count
Number of S1apPaging Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apPathSwitchReq uest
count
Number of S1apPathSwitchRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apPathSwitchReq uestAcknowledge
count
Number of S1apPathSwitchRequest Acknowledge Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apPathSwitchReq uestFailure
count
Number of S1apPathSwitchRequest Failure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apReset
count
Number of S1apReset Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apResetAcknowle dge
count
Number of S1apResetAcknowledge Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apSetupFailure
count
Number of S1apSetupFailure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apSetupRequest
count
Number of S1apSetupRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apSetupRespons e
count
Number of S1apSetupResponse Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apTraceFailureInd ication
count
Number of S1apTraceFailureIndication Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apTraceStart
count
Number of S1apTraceStart Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUECapabilityInf
count
Number of S1apUECapabilityInfo
Y
CC
event
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1148
Chapter 2 Counter Description Name
Unit
oIndication
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
Indication Msg transmitted/received by the eNB
S1apUEContextModi ficationFailure
count
Number of S1apUEContextModification Failure Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUEContextModi ficationRequest
count
Number of S1apUEContextModification Request Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUEContextModi ficationResponse
count
Number of S1apUEContextModification Response Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUEContextRele aseCommand
count
Number of S1apUEContextRelease Command Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUEContextRele aseComplete
count
Number of S1apUEContextRelease Complete Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUEContextRele aseRequest
count
Number of S1apUEContextRelease Request Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUplinkNASTran sport
count
Number of S1apUplinkNASTransport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUplinkScdma20 00tunneling
count
Number of S1apUplinkScdma2000 tunneling Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apWriteReplaceW arningRequest
count
Number of S1apWriteReplaceWarning Request Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apWriteReplaceW arningResponse
count
Number of S1apWriteReplaceWarning Response Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1149
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1apKillRequest
count
Number of S1apKillRequest Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apKillResponse
count
Number of S1apKillResponse Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apDownlinkUEAs sociatedLPPaTransp ort
count
Number of S1apDownlinkUEAssociatedLPPaTransport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUplinkUEAssoc iatedLPPaTransport
count
Number of S1apUplinkUEAssociated LPPaTransport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apDownlinkNonU EAssociatedLPPaTr ansport
count
Number of S1apDownlinkNonUE AssociatedLPPaTransport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUplinkNonUEA ssociatedLPPaTrans port
count
Number of S1apUplinkNonUEAssociated LPPaTransport Msg transmitted/received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUERadioCapab ilityMatchRequest
count
Number of S1apUERadioCapabilityMatchRequest Msg received by the eNB
Y
CC
event
int
0~21474 83647
-
-
S1apUERadioCapab ilityMatchResponse
count
Number of S1apUERadioCapabilityMatchResponse Msg transmitted by the eNB
Y
CC
event
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1150
Chapter 2 Counter Description
X2AP Message This section provides statistics on the X2AP Message transmitted/received from the eNB. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
TotalX2apTx
count
Number of Total X2AP Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
TotalX2apRx
count
Number of Total X2AP Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apErrorIndicati on
count
Number of Total X2ap ErrorIndication Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apHandoverR equest
count
Number of Total X2apHandover Request Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apHandoverR equestAcknowledge
count
Number of Total X2apHandover RequestAcknowledge Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apHandoverPr eparationFailure
count
Number of Total X2apHandover PreparationFailure Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apSNStatusTr ansfer
count
Number of Total X2apSNStatus Transfer Msg transmitted by the
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1151
Chapter 2 Counter Description Name
Unit
Tx_X2apUEContext Release
count
Tx_X2apHandoverC ancel
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of Total X2apUEContext Release Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
count
Number of Total X2apHandover Cancel Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apLoadInform ation
count
Number of Total X2apLoad Information Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apResetRequ est
count
Number of Total X2apReset Request Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apResetResp onse
count
Number of Total X2apReset Response Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apX2SetupRe quest
count
Number of Total X2apX2Setup Request Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apX2SetupRe sponse
count
Number of Total X2apX2Setup Response Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apX2SetupFai lure
count
Number of Total X2apX2Setup Failure Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apENBConfig urationUpdate
count
Number of Total X2apENB ConfigurationUpdate Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apENBConfig urationUpdateAckno wledge
count
Number of Total X2apENB ConfigurationUpdateAcknowledge Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
eNB
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1152
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Tx_X2apENBConfig urationUpdateFailure
count
Number of Total X2apENB ConfigurationUpdateFailure Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apResourceSt atusRequest
count
Number of Total X2apResource StatusRequest Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apResourceSt atusResponse
count
Number of Total X2apResource StatusResponse Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apResourceSt atusFailure
count
Number of Total X2apResource StatusFailure Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apResourceSt atusUpdate
count
Number of Total X2apResource StatusUpdate Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apHandoverR eport
count
Number of Total X2apHandover Report Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apMobilityCha ngeRequest
count
Number of Total X2apMobility ChangeRequest Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apMobilityCha ngeAcknowledge
count
Number of Total X2apMobility ChangeAcknowledge Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apMobilityCha ngeFailure
count
Number of Total X2apMobility ChangeFailure Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apCellActivati onRequest
count
Number of Total X2apCell ActivationRequest Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apCellActivati
count
Number of Total X2apCell ActivationResponse Msg
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1153
Chapter 2 Counter Description Name
Unit
onResponse
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
transmitted by the eNB
Tx_X2apCellActivati onFailure
count
Number of Total X2apCell ActivationFailure Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Tx_X2apRadioLinkF ailureIndication
count
Number of Total X2apRadio LinkFailureIndication Msg transmitted by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apErrorIndicat ion
count
Number of Total X2apError Indication Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apHandoverR equest
count
Number of Total X2apHandover Request Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apHandoverR equestAcknowledge
count
Number of Total X2apHandover RequestAcknowledge Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apHandoverP reparationFailure
count
Number of Total X2apHandover PreparationFailure Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apSNStatusTr ansfer
count
Number of Total X2apSNStatus Transfer Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apUEContext Release
count
Number of Total X2apUEContext Release Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apHandoverC ancel
count
Number of Total X2apHandover Cancel Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apLoadInform ation
count
Number of Total X2apLoad Information Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apResetRequ est
count
Number of Total X2apReset Request Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apResetResp
count
Number of Total X2apReset
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1154
Chapter 2 Counter Description Name
Unit
onse
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Response Msg received by the eNB
Rx_X2apX2SetupRe quest
count
Number of Total X2apX2Setup Request Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apX2SetupRe sponse
count
Number of Total X2apX2Setup Response Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apX2SetupFai lure
count
Number of Total X2apX2Setup Failure Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apENBConfig urationUpdate
count
Number of Total X2apENB ConfigurationUpdate Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apENBConfig urationUpdateAckno wledge
count
Number of Total X2apENB ConfigurationUpdateAcknowledge Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apENBConfig urationUpdateFailure
count
Number of Total X2apENB ConfigurationUpdateFailure Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apResourceSt atusRequest
count
Number of Total X2apResource StatusRequest Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apResourceSt atusResponse
count
Number of Total X2apResource StatusResponse Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apResourceSt atusFailure
count
Number of Total X2apResource StatusFailure Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apResourceSt atusUpdate
count
Number of Total X2apResource StatusUpdate Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1155
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Rx_X2apHandoverR eport
count
Number of Total X2apHandover Report Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apMobilityCha ngeRequest
count
Number of Total X2apMobility ChangeRequest Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apMobilityCha ngeAcknowledge
count
Number of Total X2apMobility ChangeAcknowledge Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apMobilityCha ngeFailure
count
Number of Total X2apMobility ChangeFailure Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apCellActivati onRequest
count
Number of Total X2apCell ActivationRequest Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apCellActivati onResponse
count
Number of Total X2apCell ActivationResponse Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apCellActivati onFailure
count
Number of Total X2apCell ActivationFailure Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Rx_X2apRadioLinkF ailureIndication
count
Number of Total X2apRadioLink FailureIndication Msg received by the eNB
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1156
Chapter 2 Counter Description
Traffic Distribution Throughput Distribution This section provides statistics on the packet throughput distribution. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULThruBin1
count
Number of uplink RBs with 0 Kbps ≤ throughput < 100 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin2
count
Number of uplink RBs with 100 Kbps ≤ throughput < 200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin3
count
Number of uplink RBs with 200 Kbps ≤ throughput < 300 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin4
count
Number of uplink RBs with 300 Kbps ≤ throughput < 400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin5
count
Number of uplink RBs with 400 Kbps ≤ throughput < 500 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin6
count
Number of uplink RBs with 500 Kbps ≤
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1157
Chapter 2 Counter Description Name
Unit
ULThruBin7
count
ULThruBin8
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of uplink RBs with 600 Kbps ≤ throughput < 700 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of uplink RBs with 700 Kbps ≤ throughput < 800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin9
count
Number of uplink RBs with 800 Kbps ≤ throughput < 900 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin10
count
Number of uplink RBs with 900 Kbps ≤ throughput < 1000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin11
count
Number of uplink RBs with 1000 Kbps ≤ throughput < 1200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin12
count
Number of uplink RBs with 1200 Kbps ≤ throughput < 1400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin13
count
Number of uplink RBs with 1400 Kbps ≤ throughput < 1600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin14
count
Number of uplink RBs with 1600 Kbps ≤ throughput < 1800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin15
count
Number of uplink RBs with 1800 Kbps ≤ throughput < 2000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin16
count
Number of uplink RBs with 2000 Kbps ≤ throughput < 2200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin17
count
Number of uplink RBs with 22000 Kbps ≤ throughput < 2400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin18
count
Number of uplink RBs with 2400 Kbps ≤ throughput < 2600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin19
count
Number of uplink RBs with 2600 Kbps ≤ throughput < 2800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin20
count
Number of uplink RBs with 2800 Kbps ≤ throughput < 3000 Kbps
Y
CC
event
int
0~2147483647
-
-
throughput < 600 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1158
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULThruBin21
count
Number of uplink RBs with 3000 Kbps ≤ throughput < 3400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin22
count
Number of uplink RBs with 3400 Kbps ≤ throughput < 3800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin23
count
Number of uplink RBs with 3800 Kbps ≤ throughput < 4200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin24
count
Number of uplink RBs with 4200 Kbps ≤ throughput < 4600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin25
count
Number of uplink RBs with 4600 Kbps ≤ throughput < 5000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin26
count
Number of uplink RBs with 5000 Kbps ≤ throughput < 5400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin27
count
Number of uplink RBs with 5400 Kbps ≤ throughput < 5800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin28
count
Number of uplink RBs with 5800 Kbps ≤ throughput < 6200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin29
count
Number of uplink RBs with 6200 Kbps ≤ throughput < 6600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin30
count
Number of uplink RBs with 6600 Kbps ≤ throughput < 7000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin31
count
Number of uplink RBs with 7000 Kbps ≤ throughput < 7800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin32
count
Number of uplink RBs with 7800 Kbps ≤ throughput < 8600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin33
count
Number of uplink RBs with 8600 Kbps ≤ throughput < 9400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin34
count
Number of uplink RBs with 9400 Kbps ≤ throughput < 10200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin35
count
Number of uplink RBs with 10200 Kbps ≤
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1159
Chapter 2 Counter Description Name
Unit
ULThruBin36
count
ULThruBin37
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of uplink RBs with 11000 Kbps ≤ throughput < 11800 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of uplink RBs with 11800 Kbps ≤ throughput < 12600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin38
count
Number of uplink RBs with 12600 Kbps ≤ throughput < 13400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin39
count
Number of uplink RBs with 13400 Kbps ≤ throughput < 14200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin40
count
Number of uplink RBs with 14200 Kbps ≤ throughput < 15000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin41
count
Number of uplink RBs with 15000 Kbps ≤ throughput < 16600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin42
count
Number of uplink RBs with 16600 Kbps ≤ throughput < 18200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin43
count
Number of uplink RBs with 18200 Kbps ≤ throughput < 19800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin44
count
Number of uplink RBs with 19800 Kbps ≤ throughput < 21400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin45
count
Number of uplink RBs with 21400 Kbps ≤ throughput < 23000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin46
count
Number of uplink RBs with 23000 Kbps ≤ throughput < 24600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin47
count
Number of uplink RBs with 24600 Kbps ≤ throughput < 26200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin48
count
Number of uplink RBs with 26200 Kbps ≤ throughput < 27800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin49
count
Number of uplink RBs with 27800 Kbps ≤ throughput < 29400 Kbps
Y
CC
event
int
0~2147483647
-
-
throughput < 11000 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1160
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULThruBin50
count
Number of uplink RBs with 29400 Kbps ≤ throughput < 31000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin51
count
Number of uplink RBs with 31000 Kbps ≤ throughput < 34200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin52
count
Number of uplink RBs with 34200 Kbps ≤ throughput < 37400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin53
count
Number of uplink RBs with 37400 Kbps ≤ throughput < 40600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin54
count
Number of uplink RBs with 40600 Kbps ≤ throughput < 43800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin55
count
Number of uplink RBs with 43800 Kbps ≤ throughput < 47000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin56
count
Number of uplink RBs with 47000 Kbps ≤ throughput < 50200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin57
count
Number of uplink RBs with 50200 Kbps ≤ throughput < 53400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin58
count
Number of uplink RBs with 53400 Kbps ≤ throughput < 56600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin59
count
Number of uplink RBs with 56600 Kbps ≤ throughput < 59800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin60
count
Number of uplink RBs with 59800 Kbps ≤ throughput < 63000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin61
count
Number of uplink RBs with 63000 Kbps ≤ throughput < 69400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin62
count
Number of uplink RBs with 69400 Kbps ≤ throughput < 75800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin63
count
Number of uplink RBs with 75800 Kbps ≤ throughput < 82200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin64
count
Number of uplink RBs with 82200 Kbps ≤
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1161
Chapter 2 Counter Description Name
Unit
ULThruBin65
count
ULThruBin66
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of uplink RBs with 88600 Kbps ≤ throughput < 95000 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of uplink RBs with 95000 Kbps ≤ throughput < 101400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin67
count
Number of uplink RBs with 101400 Kbps ≤ throughput < 107800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin68
count
Number of uplink RBs with 107800 Kbps ≤ throughput < 114200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin69
count
Number of uplink RBs with 114200 Kbps ≤ throughput < 120600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin70
count
Number of uplink RBs with 120600 Kbps ≤ throughput < 127000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin71
count
Number of uplink RBs with 127000 Kbps ≤ throughput < 139800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin72
count
Number of uplink RBs with 139800 Kbps ≤ throughput < 152600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin73
count
Number of uplink RBs with 152600 Kbps ≤ throughput < 165400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin74
count
Number of uplink RBs with 165400 Kbps ≤ throughput < 178200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin75
count
Number of uplink RBs with 178200 Kbps ≤ throughput < 191000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin76
count
Number of uplink RBs with 191000 Kbps ≤ throughput < 203800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin77
count
Number of uplink RBs with 203800 Kbps ≤ throughput < 216600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin78
count
Number of uplink RBs with 216600 Kbps ≤ throughput < 229400 Kbps
Y
CC
event
int
0~2147483647
-
-
throughput < 88600 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1162
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ULThruBin79
count
Number of uplink RBs with 229400 Kbps ≤ throughput < 242200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin80
count
Number of uplink RBs with 242200 Kbps ≤ throughput < 255000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin81
count
Number of uplink RBs with 255000 Kbps ≤ throughput < 280600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin82
count
Number of uplink RBs with 280600 Kbps ≤ throughput < 306200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin83
count
Number of uplink RBs with 306200 Kbps ≤ throughput < 331800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin84
count
Number of uplink RBs with 331800 Kbps ≤ throughput < 357400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin85
count
Number of uplink RBs with 357400 Kbps ≤ throughput < 383000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin86
count
Number of uplink RBs with 383000 Kbps ≤ throughput < 408600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin87
count
Number of uplink RBs with 408600 Kbps ≤ throughput < 434200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin88
count
Number of uplink RBs with 434200 Kbps ≤ throughput < 459800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin89
count
Number of uplink RBs with 459800 Kbps ≤ throughput < 485400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin90
count
Number of uplink RBs with 485400 Kbps ≤ throughput < 511000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin91
count
Number of uplink RBs with 511000 Kbps ≤ throughput < 562200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin92
count
Number of uplink RBs with 562200 Kbps ≤ throughput < 613400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin93
count
Number of uplink RBs with 613400 Kbps ≤
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1163
Chapter 2 Counter Description Name
Unit
ULThruBin94
count
ULThruBin95
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of uplink RBs with 664600 Kbps ≤ throughput < 715800 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of uplink RBs with 715800 Kbps ≤ throughput < 767000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin96
count
Number of uplink RBs with 767000 Kbps ≤ throughput < 818200 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin97
count
Number of uplink RBs with 818200 Kbps ≤ throughput < 869400 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin98
count
Number of uplink RBs with 869400 Kbps ≤ throughput < 920600 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin99
count
Number of uplink RBs with 920600 Kbps ≤ throughput < 971800 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin100
count
Number of uplink RBs with 971800 Kbps ≤ throughput < 1023000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruBin101
count
Number of uplink RBs with throughput ≥ 1023000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin1
count
Number of downlink RBs with 0 Kbps ≤ throughput < 100 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin2
count
Number of downlink RBs with 100 Kbps ≤ throughput < 200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin3
count
Number of downlink RBs with 200 Kbps ≤ throughput < 300 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin4
count
Number of downlink RBs with 300 Kbps ≤ throughput < 400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin5
count
Number of downlink RBs with 400 Kbps ≤ throughput < 500 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin6
count
Number of downlink RBs with 500 Kbps ≤ throughput < 600 Kbps
Y
CC
event
int
0~2147483647
-
-
throughput < 664600 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1164
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLThruBin7
count
Number of downlink RBs with 600 Kbps ≤ throughput < 700 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin8
count
Number of downlink RBs with 700 Kbps ≤ throughput < 800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin9
count
Number of downlink RBs with 800 Kbps ≤ throughput < 900 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin10
count
Number of downlink RBs with 900 Kbps ≤ throughput < 1000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin11
count
Number of downlink RBs with 1000 Kbps ≤ throughput < 1200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin12
count
Number of downlink RBs with 1200 Kbps ≤ throughput < 1400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin13
count
Number of downlink RBs with 1400 Kbps ≤ throughput < 1600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin14
count
Number of downlink RBs with 1600 Kbps ≤ throughput < 1800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin15
count
Number of downlink RBs with 1800 Kbps ≤ throughput < 2000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin16
count
Number of downlink RBs with 2000 Kbps ≤ throughput < 2200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin17
count
Number of downlink RBs with 2200 Kbps ≤ throughput < 2400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin18
count
Number of downlink RBs with 2400 Kbps ≤ throughput < 2600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin19
count
Number of downlink RBs with 2600 Kbps ≤ throughput < 2800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin20
count
Number of downlink RBs with 2800 Kbps ≤ throughput < 3000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin21
count
Number of downlink RBs with 3000 Kbps ≤
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1165
Chapter 2 Counter Description Name
Unit
DLThruBin22
count
DLThruBin23
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of downlink RBs with 3400 Kbps ≤ throughput < 3800 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of downlink RBs with 3800 Kbps ≤ throughput < 4200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin24
count
Number of downlink RBs with 4200 Kbps ≤ throughput < 4600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin25
count
Number of downlink RBs with 4600 Kbps ≤ throughput < 5000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin26
count
Number of downlink RBs with 5000 Kbps ≤ throughput < 5400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin27
count
Number of downlink RBs with 5400 Kbps ≤ throughput < 5800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin28
count
Number of downlink RBs with 5800 Kbps ≤ throughput < 6200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin29
count
Number of downlink RBs with 6200 Kbps ≤ throughput < 6600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin30
count
Number of downlink RBs with 6600 Kbps ≤ throughput < 7000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin31
count
Number of downlink RBs with 7000 Kbps ≤ throughput < 7800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin32
count
Number of downlink RBs with 7800 Kbps ≤ throughput < 8600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin33
count
Number of downlink RBs with 8600 Kbps ≤ throughput < 9400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin34
count
Number of downlink RBs with 9400 Kbps ≤ throughput < 10200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin35
count
Number of downlink RBs with 10200 Kbps ≤ throughput < 11000 Kbps
Y
CC
event
int
0~2147483647
-
-
throughput < 3400 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1166
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLThruBin36
count
Number of downlink RBs with 11000 Kbps ≤ throughput < 11800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin37
count
Number of downlink RBs with 11800 Kbps ≤ throughput < 12600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin38
count
Number of downlink RBs with 12600 Kbps ≤ throughput < 13400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin39
count
Number of downlink RBs with 13400 Kbps ≤ throughput < 14200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin40
count
Number of downlink RBs with 14200 Kbps ≤ throughput < 15000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin41
count
Number of downlink RBs with 15000 Kbps ≤ throughput < 16600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin42
count
Number of downlink RBs with 16600 Kbps ≤ throughput < 18200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin43
count
Number of downlink RBs with 18200 Kbps ≤ throughput < 19800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin44
count
Number of downlink RBs with 19800 Kbps ≤ throughput < 21400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin45
count
Number of downlink RBs with 21400 Kbps ≤ throughput < 23000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin46
count
Number of downlink RBs with 23000 Kbps ≤ throughput < 24600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin47
count
Number of downlink RBs with 24600 Kbps ≤ throughput < 26200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin48
count
Number of downlink RBs with 26200 Kbps ≤ throughput < 27800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin49
count
Number of downlink RBs with 27800 Kbps ≤ throughput < 29400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin50
count
Number of downlink RBs with 29400 Kbps ≤
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1167
Chapter 2 Counter Description Name
Unit
DLThruBin51
count
DLThruBin52
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of downlink RBs with 31000 Kbps ≤ throughput < 34200 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of downlink RBs with 34200 Kbps ≤ throughput < 37400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin53
count
Number of downlink RBs with 37400 Kbps ≤ throughput < 40600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin54
count
Number of downlink RBs with 40600 Kbps ≤ throughput < 43800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin55
count
Number of downlink RBs with 43800 Kbps ≤ throughput < 47000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin56
count
Number of downlink RBs with 47000 Kbps ≤ throughput < 50200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin57
count
Number of downlink RBs with 50200 Kbps ≤ throughput < 53400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin58
count
Number of downlink RBs with 53400 Kbps ≤ throughput < 56600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin59
count
Number of downlink RBs with 56600 Kbps ≤ throughput < 59800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin60
count
Number of downlink RBs with 59800 Kbps ≤ throughput < 63000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin61
count
Number of downlink RBs with 63000 Kbps ≤ throughput < 69400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin62
count
Number of downlink RBs with 69400 Kbps ≤ throughput < 75800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin63
count
Number of downlink RBs with 75800 Kbps ≤ throughput < 82200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin64
count
Number of downlink RBs with 82200 Kbps ≤ throughput < 88600 Kbps
Y
CC
event
int
0~2147483647
-
-
throughput < 31000 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1168
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLThruBin65
count
Number of downlink RBs with 88600 Kbps ≤ throughput < 95000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin66
count
Number of downlink RBs with 95000 Kbps ≤ throughput < 101400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin67
count
Number of downlink RBs with 101400 Kbps ≤ throughput < 107800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin68
count
Number of downlink RBs with 107800 Kbps ≤ throughput < 114200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin69
count
Number of downlink RBs with 114200 Kbps ≤ throughput < 120600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin70
count
Number of downlink RBs with 120600 Kbps ≤ throughput < 127000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin71
count
Number of downlink RBs with 127000 Kbps ≤ throughput < 139800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin72
count
Number of downlink RBs with 139800 Kbps ≤ throughput < 152600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin73
count
Number of downlink RBs with 152600 Kbps ≤ throughput < 165400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin74
count
Number of downlink RBs with 165400 Kbps ≤ throughput < 178200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin75
count
Number of downlink RBs with 178200 Kbps ≤ throughput < 191000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin76
count
Number of downlink RBs with 191000 Kbps ≤ throughput < 203800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin77
count
Number of downlink RBs with 203800 Kbps ≤ throughput < 216600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin78
count
Number of downlink RBs with 216600 Kbps ≤ throughput < 229400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin79
count
Number of downlink RBs with 229400 Kbps
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1169
Chapter 2 Counter Description Name
Unit
DLThruBin80
count
DLThruBin81
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of downlink RBs with 242200 Kbps ≤ throughput < 255000 Kbps
Y
CC
event
int
0~2147483647
-
-
count
Number of downlink RBs with 255000 Kbps ≤ throughput < 280600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin82
count
Number of downlink RBs with 280600 Kbps ≤ throughput < 306200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin83
count
Number of downlink RBs with 306200 Kbps ≤ throughput < 331800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin84
count
Number of downlink RBs with 331800 Kbps ≤ throughput < 357400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin85
count
Number of downlink RBs with 357400 Kbps ≤ throughput < 383000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin86
count
Number of downlink RBs with 383000 Kbps ≤ throughput < 408600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin87
count
Number of downlink RBs with 408600 Kbps ≤ throughput < 434200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin88
count
Number of downlink RBs with 434200 Kbps ≤ throughput < 459800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin89
count
Number of downlink RBs with 459800 Kbps ≤ throughput < 485400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin90
count
Number of downlink RBs with 485400 Kbps ≤ throughput < 511000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin91
count
Number of downlink RBs with 511000 Kbps ≤ throughput < 562200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin92
count
Number of downlink RBs with 562200 Kbps ≤ throughput < 613400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin93
count
Number of downlink RBs with 613400 Kbps ≤ throughput < 664600 Kbps
Y
CC
event
int
0~2147483647
-
-
≤ throughput < 242200 Kbps
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1170
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLThruBin94
count
Number of downlink RBs with 664600 Kbps ≤ throughput < 715800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin95
count
Number of downlink RBs with 715800 Kbps ≤ throughput < 767000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin96
count
Number of downlink RBs with 767000 Kbps ≤ throughput < 818200 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin97
count
Number of downlink RBs with 818200 Kbps ≤ throughput < 869400 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin98
count
Number of downlink RBs with 869400 Kbps ≤ throughput < 920600 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin99
count
Number of downlink RBs with 920600 Kbps ≤ throughput < 971800 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin100
count
Number of downlink RBs with 971800 Kbps ≤ throughput < 1023000 Kbps
Y
CC
event
int
0~2147483647
-
-
DLThruBin101
count
Number of downlink RBs with throughput ≥ 1023000 Kbps
Y
CC
event
int
0~2147483647
-
-
ULThruAvg
Kbps
Average of the user uplink throughputs collected
Y
GAUGE
event
int
0~2147483647
ULThruTot/ ULThruCnt
sum(ULThruTot)/ sum(ULThruCnt)
ULThruMax
Kbps
Maximum value of the user uplink throughput collected
Y
GAUGE
event
int
0~2147483647
-
max(ULThruMax)
ULThruMin
Kbps
Minimum value of the user uplink throughput collected
Y
GAUGE
event
int
0~2147483647
-
min(ULThruMin)
ULThruTot
Kbps
Sum of the user uplink throughputs collected
Y
GAUGE
event
int
0~2147483647
-
-
ULThruCnt
count
Number of user uplink throughput collections
Y
GAUGE
event
int
0~2147483647
-
-
DLThruAvg
Kbps
Average of the user downlink throughputs collected
Y
GAUGE
event
int
0~2147483647
DLThruTot/ DLThruCnt
sum(DLThruTot)/ sum(DLThruCnt)
DLThruMax
Kbps
Maximum value of the user downlink throughputs collected
Y
GAUGE
event
int
0~2147483647
-
max(DLThruMax)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1171
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLThruMin
Kbps
Minimum value of the user downlink throughputs collected
Y
GAUGE
event
int
0~2147483647
-
min(DLThruMin)
DLThruTot
Kbps
Sum of the user downlink throughputs collected
Y
GAUGE
event
int
0~2147483647
-
-
DLThruCnt
count
Number of user downlink throughput collections
Y
GAUGE
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1172
Chapter 2 Counter Description
Delay Distribution This section provides statistics on the packet delay distribution. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RlcDLDelayBin1
count
Number of downlink RBs with 0 ms ≤ delay < 10 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin2
count
Number of downlink RBs with 10 ms ≤ delay < 20 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin3
count
Number of downlink RBs with 20 ms ≤ delay < 30 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin4
count
Number of downlink RBs with 30 ms ≤ delay < 40 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin5
count
Number of downlink RBs with 40 ms ≤ delay < 50 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin6
count
Number of downlink RBs with 50 ms ≤ delay < 60 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin7
count
Number of downlink RBs with 60 ms ≤ delay < 70 ms
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1173
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RlcDLDelayBin8
count
Number of downlink RBs with 70 ms ≤ delay < 80 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin9
count
Number of downlink RBs with 80 ms ≤ delay < 90 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin10
count
Number of downlink RBs with 90 ms ≤ delay < 100 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin11
count
Number of downlink RBs with 100 ms ≤ delay < 110 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin12
count
Number of downlink RBs with 110 ms ≤ delay < 120 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin13
count
Number of downlink RBs with 120 ms ≤ delay < 130 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin14
count
Number of downlink RBs with 130 ms ≤ delay < 140 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin15
count
Number of downlink RBs with 140 ms ≤ delay < 150 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin16
count
Number of downlink RBs with 150 ms ≤ delay < 160 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin17
count
Number of downlink RBs with 160 ms ≤ delay < 170 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin18
count
Number of downlink RBs with 170 ms ≤ delay < 180 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin19
count
Number of downlink RBs with 180 ms ≤ delay < 190 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin20
count
Number of downlink RBs with 190 ms ≤ delay < 200 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin21
count
Number of downlink RBs with 200 ms ≤ delay < 210 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin22
count
Number of downlink RBs with 210
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1174
Chapter 2 Counter Description Name
Unit
RlcDLDelayBin23
count
RlcDLDelayBin24
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of downlink RBs with 220 ms ≤ delay < 230 ms
Y
CC
event
int
0~2147483647
-
-
count
Number of downlink RBs with 230 ms ≤ delay < 240 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin25
count
Number of downlink RBs with 240 ms ≤ delay < 250 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin26
count
Number of downlink RBs with 250 ms ≤ delay < 260 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin27
count
Number of downlink RBs with 260 ms ≤ delay < 270 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin28
count
Number of downlink RBs with 270 ms ≤ delay < 280 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin29
count
Number of downlink RBs with 280 ms ≤ delay < 290 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin30
count
Number of downlink RBs with 290 ms ≤ delay < 300 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin31
count
Number of downlink RBs with 300 ms ≤ delay < 320 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin32
count
Number of downlink RBs with 320 ms ≤ delay < 340 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin33
count
Number of downlink RBs with 340 ms ≤ delay < 360 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin34
count
Number of downlink RBs with 360 ms ≤ delay < 380 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin35
count
Number of downlink RBs with 380 ms ≤ delay < 400 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin36
count
Number of downlink RBs with 400 ms ≤ delay < 420 ms
Y
CC
event
int
0~2147483647
-
-
ms ≤ delay < 220 ms
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1175
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RlcDLDelayBin37
count
Number of downlink RBs with 420 ms ≤ delay < 440 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin38
count
Number of downlink RBs with 440 ms ≤ delay < 460 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin39
count
Number of downlink RBs with 460 ms ≤ delay < 480 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin40
count
Number of downlink RBs with 480 ms ≤ delay < 500 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin41
count
Number of downlink RBs with 500 ms ≤ delay < 550 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin42
count
Number of downlink RBs with 550 ms ≤ delay < 600 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin43
count
Number of downlink RBs with 600 ms ≤ delay < 650 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin44
count
Number of downlink RBs with 650 ms ≤ delay < 700 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin45
count
Number of downlink RBs with 700 ms ≤ delay < 750 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin46
count
Number of downlink RBs with 750 ms ≤ delay < 800 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin47
count
Number of downlink RBs with 800 ms ≤ delay < 850 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin48
count
Number of downlink RBs with 850 ms ≤ delay < 900 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin49
count
Number of downlink RBs with 900 ms ≤ delay < 950 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin50
count
Number of downlink RBs with 950 ms ≤ delay < 1000 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin51
count
Number of downlink RBs with 1000
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1176
Chapter 2 Counter Description Name
Unit
RlcDLDelayBin52
count
RlcDLDelayBin53
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Number of downlink RBs with 1100 ms ≤ delay < 1200 ms
Y
CC
event
int
0~2147483647
-
-
count
Number of downlink RBs with 1200 ms ≤ delay < 1300 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin54
count
Number of downlink RBs with 1300 ms ≤ delay < 1400 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin55
count
Number of downlink RBs with 1400 ms ≤ delay < 1500 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin56
count
Number of downlink RBs with 1500 ms ≤ delay < 1600 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin57
count
Number of downlink RBs with 1600 ms ≤ delay < 1700 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin58
count
Number of downlink RBs with 1700 ms ≤ delay < 1800 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin59
count
Number of downlink RBs with 1800 ms ≤ delay < 1900 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin60
count
Number of downlink RBs with 1900 ms ≤ delay < 2000 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin61
count
Number of downlink RBs with 2000 ms ≤ delay < 2100 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin62
count
Number of downlink RBs with 2100 ms ≤ delay < 2200 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin63
count
Number of downlink RBs with 2200 ms ≤ delay < 2300 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin64
count
Number of downlink RBs with 2300 ms ≤ delay < 2400 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin65
count
Number of downlink RBs with 2400 ms ≤ delay < 2500 ms
Y
CC
event
int
0~2147483647
-
-
ms ≤ delay < 1100 ms
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1177
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RlcDLDelayBin66
count
Number of downlink RBs with 2500 ms ≤ delay < 2600 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin67
count
Number of downlink RBs with 2600 ms ≤ delay < 2700 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin68
count
Number of downlink RBs with 2700 ms ≤ delay < 2800 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin69
count
Number of downlink RBs with 2800 ms ≤ delay < 2900 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin70
count
Number of downlink RBs with 2900 ms ≤ delay < 3000 ms
Y
CC
event
int
0~2147483647
-
-
RlcDLDelayBin71
count
Number of downlink RBs with delay ≥ 3000 ms
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1178
Chapter 2 Counter Description
Drop Distribution This section provides statistics on the packet drop and loss distribution. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduDropRate DLBin1
count
Number of downlink RBs with SDU packet drop rate ≤ 0 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduDropRate DLBin2
count
Number of downlink RBs with 0 ppm < SDU packet drop rate ≤ 1 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduDropRate DLBin3
count
Number of downlink RBs with 1 ppm < SDU packet drop rate ≤ 10 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduDropRate DLBin4
count
Number of downlink RBs with 10 ppm < SDU packet drop rate ≤ 100 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduDropRate DLBin5
count
Number of downlink RBs with 100 ppm < SDU packet drop rate ≤ 1000 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduDropRate DLBin6
count
Number of downlink RBs with 1000 ppm < SDU packet drop rate ≤ 10000 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduDropRate DLBin7
count
Number of downlink RBs with 10000 ppm < SDU packet drop rate ≤ 100000 ppm
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1179
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
PdcpSduDropRate DLBin8
count
Number of downlink RBs with 100000 ppm < SDU packet drop rate ≤ 1000000 ppm
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin1
count
Number of downlink RBs with PDU packet drop rate ≤ 0
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin2
count
Number of downlink RBs with 0 < PDU packet drop rate ≤ 0.000001
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin3
count
Number of downlink RBs with 0.000001 < PDU packet drop rate ≤ 0.00001
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin4
count
Number of downlink RBs with 0.00001 < PDU packet drop rate ≤ 0.0001
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin5
count
Number of downlink RBs with 0.0001 < PDU packet drop rate ≤ 0.001
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin6
count
Number of downlink RBs with 0.001 < PDU packet drop rate ≤ 0.01
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin7
count
Number of downlink RBs with 0.01 < PDU packet drop rate ≤ 0.1
Y
CC
event
int
0~2147483 647
-
-
RlcSduDropRateD LBin8
count
Number of downlink RBs with 0.1 < PDU packet drop rate ≤ 1
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate ULBin1
count
Number of uplink RBs with SDU packet loss rate ≤ 0 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate ULBin2
count
Number of uplink RBs with 0 ppm < SDU packet loss rate ≤ 1 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate ULBin3
count
Number of uplink RBs with 1 ppm < SDU packet loss rate ≤ 10 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate ULBin4
count
Number of uplink RBs with 10 ppm < SDU packet loss rate ≤ 100 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate ULBin5
count
Number of uplink RBs with 100 ppm < SDU packet loss rate ≤ 1000 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate
count
Number of uplink RBs with 1000 ppm < SDU
Y
CC
event
int
0~2147483
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1180
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
packet loss rate ≤ 10000 ppm
ULBin6
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
647
PdcpSduLossRate ULBin7
count
Number of uplink RBs with 10000 ppm < SDU packet loss rate ≤ 100000 ppm
Y
CC
event
int
0~2147483 647
-
-
PdcpSduLossRate ULBin8
count
Number of uplink RBs with 100000 ppm < SDU packet loss rate ≤ 1000000 ppm
Y
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1181
Chapter 2 Counter Description
CQI Distribution This section provides statistics on the CQI distribution. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CQI1Bin
count
Number of RBs that use CQI 1
Y
CC
event
int
0~2147483647
-
-
CQI2Bin
count
Number of RBs that use CQI 2
Y
CC
event
int
0~2147483647
-
-
CQI3Bin
count
Number of RBs that use CQI 3
Y
CC
event
int
0~2147483647
-
-
CQI4Bin
count
Number of RBs that use CQI 4
Y
CC
event
int
0~2147483647
-
-
CQI5Bin
count
Number of RBs that use CQI 5
Y
CC
event
int
0~2147483647
-
-
CQI6Bin
count
Number of RBs that use CQI 6
Y
CC
event
int
0~2147483647
-
-
CQI7Bin
count
Number of RBs that use CQI 7
Y
CC
event
int
0~2147483647
-
-
CQI8Bin
count
Number of RBs that use CQI 8
Y
CC
event
int
0~2147483647
-
-
CQI9Bin
count
Number of RBs that use CQI 9
Y
CC
event
int
0~2147483647
-
-
CQI10Bin
count
Number of RBs that use CQI 10
Y
CC
event
int
0~2147483647
-
-
CQI11Bin
count
Number of RBs that use CQI 11
Y
CC
event
int
0~2147483647
-
-
CQI12Bin
count
Number of RBs that use CQI 12
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1182
Chapter 2 Counter Description Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CQI13Bin
count
Number of RBs that use CQI 13
Y
CC
event
int
0~2147483647
-
-
CQI14Bin
count
Number of RBs that use CQI 14
Y
CC
event
int
0~2147483647
-
-
CQI15Bin
count
Number of RBs that use CQI 15
Y
CC
event
int
0~2147483647
-
-
CQI16Bin
count
Number of RBs that use CQI 16
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1183
Chapter 2 Counter Description
Carrier Aggregation Carrier Aggregation capable UEs (PCell) This section provides statistics on the number of accesses of carrier aggregation capable UEs (PCell). Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CaCapaPCellUE
count
Number of CA capable UEs (PCell)
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1184
Chapter 2 Counter Description Figure 597. Initial attach case UE
eNB
MME Initial Context Setup Request 1
CaCapaPCellUE
RRC Connection Reconfiguration RRC Connection Reconfiguration Complete Initial Context Setup Response
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1185
Chapter 2 Counter Description Figure 598. X2 handover case UE
Source eNB
Target eNB
MME
UE moves to Inter eNB Cell Measurement Report Handover Request
RRC Connection Reconfiguration
Handover Request Acknowledge
1
CaCapaPCellUE
SN Status Transfer RRC Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge UE Context Release
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1186
Chapter 2 Counter Description Figure 599. S1 handover case UE
Source eNB
Target eNB
MME
UE moves to Inter eNB Cell Measurement Report Handover Required Handover Request 1
CaCapaPCellUE
Handover Request Acknowledge
Handover Command RRC Connection Reconfiguration eNB Status Transfer MME Status Transfer RRC Connection Reconfiguration Complete Handover Notify UE Context Release Command UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1187
Chapter 2 Counter Description Figure 600. Intra eNB handover case UE
Source Cell
Target Cell
Measurement Report Target Cell Preparation 1
CaCapaPCellUE
RRC Connection Reconfiguration RRC Connection Reconfiguration Complete
Figure 601. Rrc Reestablishment UE
PCell
RRC Connection Reestablishment Request RRC Connection Reestablishment RRC Connection Reestablishment Complete RRC Connection Reconfiguration
1
CaCapaPCellUE
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1188
Chapter 2 Counter Description
Carrier Aggregation Message count for Addition-Release (SCell) This section provides statistics on the count of additions/releases of carrier aggregation per event (SCell). Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
SCellAddAtt
count
Scell Addition attempt count (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddSucc_Rrc Sig
count
Number of successes in addition to colocated SCell or successes in SCell addition by HO-in procedure (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddSucc_Ev entA4
count
Number of successes in SCell addition by Event A4 (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddSucc_Ev entA6
count
Number of successes in SCell addition (change) by Event A6 (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddSucc_Rrc Resetup
count
Number of successes in addition to SCell after RRC connection reestablishment procedures (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddFail_RrcS igTO
count
Number of fails in Scell addition by released calls by RRC Connection Reconfiguration T/O (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddFail_CaC apaCac
count
Number of fails in SCell addition under Carrier Aggregation Capability CAC Procedure (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellAddFail_CpC
count
Number of fails in Scell Addition under
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1189
Chapter 2 Counter Description Name
Unit
cFail
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ECCB (Scell)
SCellAddFail_CpR rmFail
count
Number of fails in Scell Addition due to resource allocation failure (Scell)
Y
CC
event
int
0~2147483647
-
-
SCellRel_RrcSig
count
Number of times that SCell Release is performed under the RRC connection reestablishment procedures (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellRel_HoOut
count
Number of times that SCell Release is performed under the HO Out procedures (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellRel_EventA2
count
Number of times that SCell Release is performed by Event A2 (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellRel_EventA6
count
Number of times that SCell Release (Change) is performed by Event A6 (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellRel_RrcReset up
count
Number of times that SCell Release is performed under the RRC connection reestablishment procedures (SCell)
Y
CC
event
int
0~2147483647
-
-
SCellRel_CaCac
count
Number of times that SCell Release is performed under the Carrier Aggregation CAC (SCell)
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1190
Chapter 2 Counter Description Figure 602. Initial attach case UE
eNB
MME
RRC Connection Establishment Initial Context Setup Request SCellAddAtt
1
Scell Decision
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
RRC Connection Reconfiguration
2
- SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail
RRC Connection Reconfiguration Complete
2
SCellAddFail_RrcSigTO
3
SCellAddSucc_RrcSig
1191
Chapter 2 Counter Description Figure 603. Intra-eNB handover case UE
Source Cell
Target Cell
Measurement Report (A3 or A5 event) Target Cell Perparation 1 SCellAddAtt Scell Decision
RRC Connection Reconfiguration
RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
2
- SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail
2
SCellAddFail_RrcSigTO
3
SCellAddSucc_RrcSig
1192
Chapter 2 Counter Description Figure 604. X2 handover case UE
Source eNB
Target eNB
MME
Measurement Report HO Decision Handover Required 1 SCellAddAtt Scell Decision 2
- SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail Handover Request Acknowledge
RRC Connection Reconfiguration
RRC Connection Reconfiguration Complete
2
SCellAddFail_RrcSigTO
3
SCellAddSucc_RrcSig
Path Switch Request
UE Context Release SCellRel_HoOut
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Path Switch Request Acknowledge
4
1193
Chapter 2 Counter Description Figure 605. S1 handover case UE
Source eNB
Target eNB
MME
Measurement Report HO Decision Handover Required Handover Request 1 SCellAddAtt Scell Decision - SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail Handover Request Acknowledge 2
RRC Connection Reconfiguration
Handover Command
RRC Connection Reconfiguration Complete
2
SCellAddFail_RrcSigTO
3
SCellAddSucc_RrcSig
Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete SCellRel_HoOut
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
4
1194
Chapter 2 Counter Description Figure 606. Event A2 case UE
eNB RRC Connected Measurement Report (A2 event) 1
RRC Connection Reconfiguration
SCellRel_EventA2
RRC Connection Reconfiguration Complete
Figure 607. Event A4 case UE
eNB RRC Connected Measurement Report (A4 event) 1
SCellAddAtt
Scell Decision 2
- SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail
2
SCellAddFail_RrcSigTO
3
SCellAddSucc_EventA4
RRC Connection Reconfiguration RRC Connection Reconfiguration Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1195
Chapter 2 Counter Description Figure 608. Event A6 case UE
PCell
Source SCell
Target SCell
Measurement Report (A6 event) 1 SCellAddAtt Scell Decision RRC Connection Reconfiguration
2
RRC Connection 2 Reconfiguration Complete SCellAddSucc_EventA6
3
- SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail SCellAddFail_RrcSigTO
Scell delete 4
SCellRel_EventA6
Scell Setup
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1196
Chapter 2 Counter Description Figure 609. RRC connection re-establishment case UE
PCell
Source SCell
Target SCell
RRC Connection Reestablishment Request Scell delete 1 SCellRel_RrcResetup
RRC Connection Reestablishment RRC Connection Reestablishment Complete 2
SCellAddAtt
Scell Decision
3
- SCellAddFail_CaCapaCac - SCellAddFail_CpCcFail - SCellAddFail_CpRrmFail
RRC Connection Reconfiguration 3
SCellAddFail_RrcSigTO
RRC Connection Reconfiguration Complete 4
SCellAddSucc_RrcResetup Scell Setup
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1197
Chapter 2 Counter Description Figure 610. RRC connection release case UE
eNB
MME
RRC Connection Establishment UE Context Release Command RRC Connection Release 1 SCellRel_RrcSig UE Context Release Complete
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1198
Chapter 2 Counter Description
Carrier Aggregation Message count for Activation-Deactivation (SCell) This section provides statistics on the count of activations/deactivations of carrier aggregation by event (SCell). Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
SCellActivation
count
The cumulated number of Scell Activations
This counter is cumulated when Scell Activations occurs
Y
CC
5.12 s
int
0~214748 3647
-
-
SCellDeactivation _TO
count
The cumulated number of SCell deactivation occurrences by reason: When deactivation timer expires (SCell)
This counter is cumulated when the Deactivation when the Deactivation timer is expired
Y
CC
5.12 s
int
0~214748 3647
-
-
SCellDeactivation _Mismatch
count
The cumulated number of SCell deactivation occurrence by reason: When CA status of eNB and that of the UE are different (SCell)
This counter is cumulated when the Deactivation when the CA Status is different between eNB and UE.
Y
CC
5.12 s
int
0~214748 3647
-
-
CRNTIcollision
count
The cumulated number of Scell Activation fail due to C-RNTI collision (The C-RNTI of UE, who requests Scell activation to SCell, is
This counter is updated by 1 when the C-RNTI requires to activate is already used in the Cell
Y
CC
5.12 s
int
0~214748 3647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1199
Chapter 2 Counter Description Name
Unit
SCellActUEAvg
count
SCellActUETot
SCellActUECnt
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
The average number of Scell activated UE
This counter is calculated when measurement period comes.
Y
SI
5.12 s
float
0~214748 3647
(SCellActU ETot/SCell ActUECnt)
(sum(SCellActUE Tot)/sum(SCellAc tUECnt))
count
The cumulated number of SCell Activated UE
This counter is updated by the average number of UE that succeed in SCell Activation during 80 msec.
-
SI
5.12 s
float
0~214748 3647
-
-
count
The collection count of SCellActUEAvg
This counter is cumulated by 1 when SCellActUE_Avg is collected
-
SI
5.12 s
int
0~214748 3647
-
-
already used in SCell)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1200
Chapter 2 Counter Description
Air MAC Packet (PCell) This section provides statistics on the DL/UL transfer bytes measured in Mac (PCell). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirMacULByte
Kbytes
The cumulated size of the MAC PDU successfully received via PUSCH during the statistics period
This counter is updated by the bytes of MAC PDU when MAC PDU successfully received via PUSCH
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacULByteCnt
count
The collection count of AirMacULByte
This counter is cumulated by 1 when AirMacULByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacULTti
TTI
The cumulated number of TTIs that have MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is updated by 1 when MAC PDU successfully received via PUSCH
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1201
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirMacULThruAv g
Kbps
The calculated number that indicates the average per-second size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10^38
((AirMacUL Byte*8)/(51 20*AirMac ULByteCnt) )*K_UNIT
((sum(AirMacULB yte)*8)/(5120*sum (AirMacULByteCn t)))*K_UNIT
AirMacULEfctivTh ruAvg
Kbps
The overall calculated size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10^38
((AirMacUL Byte*8)/Air MacULTti)* K_UNIT
((sum(AirMacULB yte)*8)/sum(AirMa cULTti))*K_UNIT
AirMacDLByte
Kbytes
The cumulated size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is updated by the bytes of MAC PDU when MAC PDU successfully received via PDSCH
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacDLByteCnt
count
The collection count of AirMacDLByte
This counter is cumulated by 1 when AirMacDLByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacDLTti
TTI
The cumulated number of TTIs that have MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is updated by 1 when MAC PDU successfully received via PDSCH
Y
CC
5.12 s
int
0~2147483647
-
-
AirMacDLThruAv g
Kbps
The calculated average per-second size of MAC
This counter is calculated when
Y
OW
Period
float
0~3.4*10^38
((AirMacDL Byte*8)/(51
((sum(AirMacDLB yte)*8)/(5120*sum
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1202
Chapter 2 Counter Description Name
Unit
Description
Trigger
PDUs which were successfully transmitted through PDSCH during the collection interval.
measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula 20*AirMac DLByteCnt) )*K_UNIT
Hourly, Daily, Monthly Formula (AirMacDLByteCn t)))*K_UNIT
AirMacDLEfctivTh ruAvg
Kbps
The overall calculated size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10^38
((AirMacDL Byte*8)/Air MacDLTti)* K_UNIT
((sum(AirMacDLB yte)*8)/sum(AirMa cDLTti))*K_UNIT
AirMacULByteCur r
Kbytes
The most recent collected AirMacULByte
This counter is updated when AirMacULByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacDLByteCur r
Kbytes
The most recent collected AirMacDLByte
This counter is updated when AirMacDLByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacULThruMin
Kbps
The minimum value of AirMacULByte
This counter is updated when the AirMacULByte is smaller than the previous value
Y
OW
5.12 s
float
0~3.4*10^38
-
min(AirMacULThr uMin)
AirMacULThruMa x
Kbps
The maximum value of AirMacULByte
This counter is updated when the AirMacULByte is greater than the previous value
Y
OW
5.12 s
float
0~3.4*10^38
-
max(AirMacULTh ruMax)
AirMacDLThruMin
Kbps
The minimum value of AirMacDLByte
This counter is updated when the AirMacDLByte is smaller than the
Y
OW
5.12 s
float
0~3.4*10^38
-
min(AirMacDLThr uMin)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1203
Chapter 2 Counter Description Name
Unit
Description
AirMacDLThruMa x
Kbps
The maximum value of AirMacDLByte
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
OW
5.12 s
float
0~3.4*10^38
-
max(AirMacDLTh ruMax)
previous value
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is updated when the AirMacDLByte is greater than the previous value
1204
Chapter 2 Counter Description
Air MAC Packet (SCell) This section provides statistics on the DL/UL transfer bytes measured by Mac (SCell). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirMacULByte
Kbytes
The cumulated number that indicates the sum of the size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is updated by the bytes of MAC PDU when MAC PDU successfully received via PUSCH
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacULByteCnt
count
The collection count of AirMacULByte
This counter is cumulated by 1 when AirMacULByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacULTti
TTI
The cumulated number of TTIs that have MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is updated by 1 when MAC PDU successfully received via PUSCH
Y
CC
5.12 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1205
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
AirMacULThruAvg
Kbps
The calculated number that indicates the average per-second size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10^38
((AirMacUL Byte*8)/(51 20*AirMac ULByteCnt) )*K_UNIT
((sum(AirMacULB yte)*8)/(5120*sum (AirMacULByteCn t)))*K_UNIT
AirMacULEfctivThr uAvg
Kbps
The overall calculated size of MAC PDUs which were successfully received through PUSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10^38
((AirMacUL Byte*8)/Air MacULTti)* K_UNIT
((sum(AirMacULB yte)*8)/sum(AirMa cULTti))*K_UNIT
AirMacDLByte
Kbytes
The cumulated size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is updated by the bytes of MAC PDU when MAC PDU successfully received via PDSCH
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacDLByteCnt
count
The collection count of AirMacDLByte
This counter is cumulated by 1 when AirMacDLByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacDLTti
TTI
The cumulated number of TTIs that have MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is updated by 1 when MAC PDU successfully received via PDSCH
Y
CC
5.12 s
int
0~2147483647
-
-
AirMacDLThruAvg
Kbps
The calculated average
This counter is
Y
OW
Period
float
0~3.4*10^38
((AirMacDL
((sum(AirMacDLB
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1206
Chapter 2 Counter Description Name
Unit
Description
Trigger
per-second size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
calculated when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula Byte*8)/(51 20*AirMac DLByteCnt) )*K_UNIT
Hourly, Daily, Monthly Formula yte)*8)/(5120*sum (AirMacDLByteCn t)))*K_UNIT
AirMacDLEfctivThr uAvg
Kbps
The overall calculated size of MAC PDUs which were successfully transmitted through PDSCH during the collection interval.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~3.4*10^38
((AirMacDL Byte*8)/Air MacDLTti)* K_UNIT
((sum(AirMacDLB yte)*8)/sum(AirMa cDLTti))*K_UNIT
AirMacULByteCurr
Kbytes
The most recent collected AirMacULByte
This counter is updated when AirMacULByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacDLByteCurr
Kbytes
The most recent collected AirMacDLByte
This counter is updated when AirMacDLByte is collected
Y
CC_LL
5.12 s
int
0~2147483647
-
-
AirMacULThruMin
Kbps
The minimum value of AirMacULByte
This counter is updated when the AirMacULByte is smaller than the previous value
Y
OW
5.12 s
float
0~3.4*10^38
-
min(AirMacULThr uMin)
AirMacULThruMax
Kbps
The maximum value of AirMacULByte
This counter is updated when the AirMacULByte is greater than the previous value
Y
OW
5.12 s
float
0~3.4*10^38
-
max(AirMacULTh ruMax)
AirMacDLThruMin
Kbps
The minimum value of AirMacDLByte
This counter is updated when the AirMacDLByte is
Y
OW
5.12 s
float
0~3.4*10^38
-
min(AirMacDLThr uMin)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1207
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
OW
5.12 s
float
0~3.4*10^38
-
max(AirMacDLTh ruMax)
smaller than the previous value AirMacDLThruMax
Kbps
The maximum value of AirMacDLByte
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is updated when the AirMacDLByte is greater than the previous value
1208
Chapter 2 Counter Description
DL Wideband CQI (PCell) This section provides statistics on the CQI report information per layer/codeword for the CA UE (PCell). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
codeword
Codeword (Number of transport blocks) 0: First transport block 1: Second transport block
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI0
count
The cumulated number of receiving CQI 0 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI0 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1
count
The cumulated number
This counter is
Y
CC
5.12 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1209
Chapter 2 Counter Description Name
Unit
Description
Trigger
of receiving CQI 1 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
cumulated by 1 when CQI1 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
DLReceivedCQI2
count
The cumulated number of receiving CQI 2 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI2 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI3
count
The cumulated number of receiving CQI 3 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI3 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI4
count
The cumulated number of receiving CQI 4 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI4 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI5
count
The cumulated number of receiving CQI 5 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is
This counter is cumulated by 1 when CQI5 is received for any layer/codeword from a CA UE that uses
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1210
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI6
count
PCell
the cell as its PCell.
The cumulated number of receiving CQI 6 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI6 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI7
count
The cumulated number of receiving CQI 7 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI7 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI8
count
The cumulated number of receiving CQI 8 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI8 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI9
count
The cumulated number of receiving CQI 9 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI9 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 0
count
The cumulated number of receiving CQI 10 for a wideband CQI per layer/codeword
This counter is cumulated by 1 when CQI10 is received for any
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1211
Chapter 2 Counter Description Name
Unit
Description
Trigger
transmitted from CA UE whose the cell is PCell
layer/codeword from a CA UE that uses the cell as its PCell.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI1 1
count
The cumulated number of receiving CQI 11 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI11 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 2
count
The cumulated number of receiving CQI 12 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI12 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 3
count
The cumulated number of receiving CQI 13 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI13 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 4
count
The cumulated number of receiving CQI 14 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
This counter is cumulated by 1 when CQI14 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 5
count
The cumulated number of receiving CQI 15 for
This counter is cumulated by 1
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1212
Chapter 2 Counter Description Name
Unit
Description
Trigger
a wideband CQI per layer/codeword transmitted from CA UE whose the cell is PCell
when CQI15 is received for any layer/codeword from a CA UE that uses the cell as its PCell.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQIM in
CQI
The minimum value of DlReceivedCQI received from CA UE whose cell is PCell
This counter is updated when the DLReceivedCQIMin is smaller than the previous value
Y
OW
Period
int
0~15
-
min(DLReceived CQIMin)
DLReceivedCQIM ax
CQI
The maximum value of DlReceivedCQI received from CA UE whose cell is PCell
This counter is updated when the DLReceivedCQIMm ax is greater than the previous value
Y
OW
Period
int
0~15
-
max(DLReceived CQIMax)
DLReceivedCQIA vg
CQI
The average value of DlReceivedCQI received from CA UE whose cell is PCell
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~15
(0*DLReceivedC QI0+1*DLReceiv edCQI1+2*DLRe ceivedCQI2+3*D LReceivedCQI3+ 4*DLReceivedCQ I4+5*DLReceived CQI5+6*DLRecei vedCQI6+7*DLR eceivedCQI7+8* DLReceivedCQI8 +9*DLReceivedC QI9+10*DLRecei vedCQI10+11*DL ReceivedCQI11+ 12*DLReceivedC QI12+13*DLRece ivedCQI13+14*D LReceivedCQI14
(0*sum(DLReceiv edCQI0)+1*sum( DLReceivedCQI1 )+2*sum(DLRecei vedCQI2)+3*sum( DLReceivedCQI3 )+4*sum(DLRecei vedCQI4)+5*sum( DLReceivedCQI5 )+6*sum(DLRecei vedCQI6)+7*sum( DLReceivedCQI7 )+8*sum(DLRecei vedCQI8)+9*sum( DLReceivedCQI9 )+10*sum(DLRec eivedCQI10)+11* sum(DLReceived CQI11)+12*sum(
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1213
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula +15*DLReceived CQI15)/(DLRecei vedCQI0+DLRec eivedCQI1+DLRe ceivedCQI2+DLR eceivedCQI3+DL ReceivedCQI4+D LReceivedCQI5+ DLReceivedCQI6 +DLReceivedCQI 7+DLReceivedC QI8+DLReceived CQI9+DLReceive dCQI10+DLRecei vedCQI11+DLRe ceivedCQI12+DL ReceivedCQI13+ DLReceivedCQI1 4+DLReceivedC QI15)
Hourly, Daily, Monthly Formula DLReceivedCQI1 2)+13*sum(DLRe ceivedCQI13)+14 *sum(DLReceived CQI14)+15*sum( DLReceivedCQI1 5))/(sum(DLRecei vedCQI0)+sum(D LReceivedCQI1)+ sum(DLReceived CQI2)+sum(DLRe ceivedCQI3)+sum (DLReceivedCQI 4)+sum(DLReceiv edCQI5)+sum(DL ReceivedCQI6)+s um(DLReceivedC QI7)+sum(DLRec eivedCQI8)+sum( DLReceivedCQI9 )+sum(DLReceive dCQI10)+sum(DL ReceivedCQI11)+ sum(DLReceived CQI12)+sum(DLR eceivedCQI13)+s um(DLReceivedC QI14)+sum(DLRe ceivedCQI15))
CQIErase
count
The cumulated number that CQI erase per Layer/Codeword is received from CA UE whose cell is PCell
This counter is cumulated by 1 when CQI erase is received for any layer/codeword from a CA UE that uses
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1214
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
the cell as its PCell.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1215
Chapter 2 Counter Description
DL Wideband CQI (SCell) This section provides statistics on the CQI report information per layer/codeword for the CA UE (SCell). Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
codeword
Codeword (Number of transport blocks) 0: First transport block 1: Second transport block
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI0
count
The cumulated number of receiving CQI 0 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI0 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1216
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI1
count
The cumulated number of receiving CQI 1 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI1 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI2
count
The cumulated number of receiving CQI 2 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI2 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI3
count
The cumulated number of receiving CQI 3 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI3 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI4
count
The cumulated number of receiving CQI 4 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI4 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI5
count
The cumulated number of
This counter is
Y
CC
5.12 s
int
0~21474
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1217
Chapter 2 Counter Description Name
Unit
Description
Trigger
receiving CQI 5 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
cumulated by 1 when CQI5 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
83647
DLReceivedCQI6
count
The cumulated number of receiving CQI 6 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI6 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI7
count
The cumulated number of receiving CQI 7 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI7 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI8
count
The cumulated number of receiving CQI 8 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI8 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI9
count
The cumulated number of receiving CQI 9 for a
This counter is cumulated by 1
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1218
Chapter 2 Counter Description Name
Unit
Description
Trigger
wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
when CQI9 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI1 0
count
The cumulated number of receiving CQI 10 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI10 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 1
count
The cumulated number of receiving CQI 11 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI11 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 2
count
The cumulated number of receiving CQI 12 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI12 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 3
count
The cumulated number of receiving CQI 13 for a wideband CQI per
This counter is cumulated by 1 when CQI13 is
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1219
Chapter 2 Counter Description Name
Unit
Description
Trigger
layer/codeword transmitted from CA UE whose the cell is SCell
received for any layer/codeword from a CA UE that uses the cell as its SCell.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
DLReceivedCQI1 4
count
The cumulated number of receiving CQI 14 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI14 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQI1 5
count
The cumulated number of receiving CQI 15 for a wideband CQI per layer/codeword transmitted from CA UE whose the cell is SCell
This counter is cumulated by 1 when CQI15 is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
DLReceivedCQIM in
CQI
The minimum value of DlReceivedCQI transmitted from CA UE whose the cell is Scell
This counter is updated when the DLReceivedCQIMin is smaller than the previous value
Y
OW
Period
int
0~15
-
min(DLReceived CQIMin)
DLReceivedCQIM ax
CQI
The maximum value of DlReceivedCQI transmitted from CA UE whose the cell is Scell
This counter is updated when the DLReceivedCQIM max is greater than the previous value
Y
OW
Period
int
0~15
-
max(DLReceived CQIMax)
DLReceivedCQIA vg
CQI
The average value of DlReceivedCQI transmitted
This counter is calculated when
Y
OW
Period
float
0~15
(0*DLRecei vedCQI0+1
(0*sum(DLReceiv edCQI0)+1*sum(
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1220
Chapter 2 Counter Description Name
Unit
Description
Trigger
from CA UE whose the cell is Scell
measurement period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula *DLReceive dCQI1+2*D LReceived CQI2+3*DL ReceivedC QI3+4*DLR eceivedCQI 4+5*DLRec eivedCQI5+ 6*DLReceiv edCQI6+7* DLReceive dCQI7+8*D LReceived CQI8+9*DL ReceivedC QI9+10*DL ReceivedC QI10+11*D LReceived CQI11+12* DLReceive dCQI12+13 *DLReceive dCQI13+14 *DLReceive dCQI14+15 *DLReceive dCQI15)/(D LReceived CQI0+DLR eceivedCQI 1+DLRecei vedCQI2+D LReceived
Hourly, Daily, Monthly Formula DLReceivedCQI1 )+2*sum(DLRecei vedCQI2)+3*sum( DLReceivedCQI3 )+4*sum(DLRecei vedCQI4)+5*sum( DLReceivedCQI5 )+6*sum(DLRecei vedCQI6)+7*sum( DLReceivedCQI7 )+8*sum(DLRecei vedCQI8)+9*sum( DLReceivedCQI9 )+10*sum(DLRec eivedCQI10)+11* sum(DLReceived CQI11)+12*sum( DLReceivedCQI1 2)+13*sum(DLRe ceivedCQI13)+14 *sum(DLReceive dCQI14)+15*sum (DLReceivedCQI 15))/(sum(DLRec eivedCQI0)+sum( DLReceivedCQI1 )+sum(DLReceive dCQI2)+sum(DLR eceivedCQI3)+su m(DLReceivedC QI4)+sum(DLRec eivedCQI5)+sum( DLReceivedCQI6 )+sum(DLReceive dCQI7)+sum(DLR 1221
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula CQI3+DLR eceivedCQI 4+DLRecei vedCQI5+D LReceived CQI6+DLR eceivedCQI 7+DLRecei vedCQI8+D LReceived CQI9+DLR eceivedCQI 10+DLRece ivedCQI11+ DLReceive dCQI12+DL ReceivedC QI13+DLRe ceivedCQI1 4+DLRecei vedCQI15)
Hourly, Daily, Monthly Formula eceivedCQI8)+su m(DLReceivedC QI9)+sum(DLRec eivedCQI10)+su m(DLReceivedC QI11)+sum(DLRe ceivedCQI12)+su m(DLReceivedC QI13)+sum(DLRe ceivedCQI14)+su m(DLReceivedC QI15))
CQIErase
count
The number of times CQI Erase was received for each layer/codeword from CA UEs that use the cell as their SCell during the collection interval.
This counter is cumulated by 1 when CQI Erase is received for any layer/codeword from a CA UE that uses the cell as its SCell.
Y
CC
5.12 s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1222
Chapter 2 Counter Description
Aggregate Maximum Bit Rate UE-AMBR Override This section provides statistics on the data when UE-AMBR override occurs. Index Name
Description
PLMN
PLMN Id; mcc in the first three-digit numbers and mnc after the three-digit numbers
cNum
Cell Id
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
S1APUEAmbrOverride
count
If the UE-AMBR value received from MME is larger than the limited MAX value, count the relevant statistics.
Y
CC
event
int
0~2147483647
-
-
X2APUEAmbrOverride
count
If the UE-AMBR value received from the source eNB at the handover is larger than the limited MAX value, count the relevant statistics.
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1223
Chapter 2 Counter Description
KPI This section calculates the KPI defined as per 3GPP TS 32.450 and provides to the EMS.
Accessibility This KPI shows the probability for an end-user to be provided with an E-RAB at request.
Probability Success Rate for E-RABs Establishment Successful attempts compared with total number of attempts for the different parts of the E-RAB establishment SAEB.NbrSu ccEstabInit.QCI RRC.SuccCo nnEstab.cause S1SIG.Conn EstabSucc QCI A1 InitialEPS BEstabSR cause 100 RRC.AttConnEstab.cause S1SIG.Conn EstabAtt SAEB.NbrAttEstabInit.QCI cause
A2 AddedEPSBE stabSR
SAEB.NbrSuccEstabAdd.QCI QCI
SAEB.NbrAttEstabAdd.QCI
QCI
100
QCI
Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1224
Chapter 2 Counter Description
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabAcces sibilityInit
%
The success rate of Initial E-RAB establishment success rate
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(SumRrcConnE stabSucc/SumR rcConnEstabAtt) *(SumS1sigS1C onnEstabSucc/S umS1sigS1Con nEstabAtt)*(Sum ErabEstabInitSu ccNbr/SumErab EstabInitAttNbr)* 100
(sum(SumRrcConn EstabSucc)/sum(Su mRrcConnEstabAtt) )*(sum(SumS1sigS1 ConnEstabSucc)/su m(SumS1sigS1Con nEstabAtt))*(sum(S umErabEstabInitSu ccNbr)/sum(SumEra bEstabInitAttNbr))*1 00
SumRrcCo nnEstabSu cc
count
The cumulated number of RRC ESTAB success count
This counter is cumulated by 1 when RRC ESTAB success count is collected
-
CC
event
int
0~21474836 47
-
-
SumRrcCo nnEstabAtt
count
The cumulated number of RRC ESTAB attempt count
This counter is cumulated by 1 when RRC ESTAB attempt count is collected
-
CC
event
int
0~21474836 47
-
-
SumS1sigS 1ConnEsta bSucc
count
The cumulated number of UE Logical S1 Connection Setup success count
This counter is cumulated when UE Logical S1 Connection Setup success is collected
-
CC
event
int
0~21474836 47
-
-
SumS1sigS
count
The cumulated
This counter
-
CC
event
int
0~21474836
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1225
Chapter 2 Counter Description Name
Unit
1ConnEsta bAtt
Description
Trigger
number of UE Logical S1 Connection Setup attempt count
is cumulated when UE Logical S1 Connection Setup attempt count is collected
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
47
SumErabE stabInitSuc cNbr
count
The cumulated number of ERAB setup success count
This counter is cumulated when ERAB setup success is collected
-
CC
event
int
0~21474836 47
-
-
SumErabE stabInitAttN br
count
The cumulated number of ERAB setup attempt count
This counter is cumulated when ERAB setup attempt is collected
-
CC
event
int
0~21474836 47
-
-
ErabAcces sibilityAdd
%
The success rate of E-RAB establishment
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(SumErabEstab AddSuccNbr/Su mErabEstabAdd AttNbr)*100
(sum(SumErabEsta bAddSuccNbr)/sum( SumErabEstabAdd AttNbr))*100
SumErabE stabAddSu ccNbr
count
The cumulated number of ERAB additional setup success count
This counter is cumulated when ERAB additional setup success is collected
-
CC
event
int
0~21474836 47
-
-
SumErabE stabAddAtt Nbr
count
The cumulated number of ERAB additional setup attempt count
This counter is cumulated when ERAB additional setup attempt
-
CC
event
int
0~21474836 47
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1226
Chapter 2 Counter Description Name
Unit
Description
ErabConne ctionFailure Rate
%
The fail ratio of E-RAB establishment
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
OW
Period
float
0~100
if((SumRrcConn EstabAtt=0)&(S umS1sigS1Con nEstabAtt=0)&( SumErabEstabI nitAttNbr=0), 0, if((SumRrcConn EstabAtt=0)|(Su mS1sigS1Conn EstabAtt=0)|(Su mErabEstabInit AttNbr =0), 100, 100(SumRrcConnE stabSucc/SumR rcConnEstabAtt) *(SumS1sigS1C onnEstabSucc/S umS1sigS1Con nEstabAtt)*(Sum ErabEstabInitSu ccNbr/SumErab EstabInitAttNbr)* 100))
if((sum(SumRrcCon nEstabAtt)=0)&(sum (SumS1sigS1Conn EstabAtt)=0)&(sum( SumErabEstabInitAt tNbr)=0), 0, if((sum(SumRrcCon nEstabAtt)=0)|(sum( SumS1sigS1ConnE stabAtt)=0)|(sum(Su mErabEstabInitAttN br)=0), 100, 100(sum(SumRrcConn EstabSucc)/sum(Su mRrcConnEstabAtt) )*(sum(SumS1sigS1 ConnEstabSucc)/su m(SumS1sigS1Con nEstabAtt))*(sum(S umErabEstabInitSu ccNbr)/sum(SumEra bEstabInitAttNbr))*1 00))
is collected This counter is calculated when measurement period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1227
Chapter 2 Counter Description
Retainability This section provides statistics on a measurement that shows how often an end-user abnormally looses an E-RAB during the time the ERAB is used. This statistics item is collected for each cell.
Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabRetainab ility
%
The number by dividing the E-RAB Release count by E-RAB holding time.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumRelActive/ RetainSession TimeUE*100
sum(SumRelActive)/s um(RetainSessionTi meUE)*100
SumRelActiv e
count
The cumulated number of bearers among active ERABs where a call is released due to abnormal operation in eNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~21474 83647
-
-
RetainSessio nTimeUE
ms
The cumulated number of in-session time of the UE
This counter is calculated when
-
CC
5.12 s
float
0~3.4*10 ^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1228
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
measurement period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1229
Chapter 2 Counter Description
Retainability per QCI This section provides statistics on the measurement that shows how often an end-user abnormally loses an E-RAB during the time the ERAB is used. This statistics item is collected for each QCI.
R1QCI x
ERAB . Re lActNbr _ QCIQCI x Index ERAB .SessionTimeQCI _ QCIQCI x
Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ErabRetainability
%
The number by dividing the E-RAB Release count by ERAB holding time.
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
RetainRelActiv e/RetainSessi onTimeQci*10 0
sum(RetainRelActi ve)/sum(RetainSes sionTimeQci)*100
RetainRelActive
count
The cumulated number of bearers among active ERABs where a call is released due to abnormal operation in eNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~21474 83647
-
-
RetainSessionTime Qci
ms
The cumulated number of in-session time of the UE
This counter is calculated when measurement period comes.
-
CC
5.12 s
float
0~3.4*1 0^38
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1230
Chapter 2 Counter Description
Integrity This section provides statistics on the data that shows how E-UTRAN impacts the service quality provided to an end-user. Payload data volume on IP level per elapsed time unit on the Uu interface.
E-UTRAN IP Throughput
V _ tp _ DL IP_ Throughput Samples
T _ tp _ DL Samples
E-UTRAN IP Latency Downlink
LatQCI x DRB.IPLatDlQCI x
Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EutranIpThroughput
Kbps
The sum of EutranIpThroug hput per QCI
This counter is calculated when measurement period comes.
Y
SI
Period
float
0~3.4*10^38
-
avg (EutranIpThroughput )
EutranIpLatency
ms
The sum of
This counter is
Y
SI
Period
float
0~60*Period*100
-
avg
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1231
Chapter 2 Counter Description Name
Unit
Description
Trigger
EutranIpLatenc y per QCI
calculated when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula (EutranIpLatency)
0
IntegrityEutranIpThr oughputTot
Kbps
The cumulated number of collected IpThru
This counter is calculated when measurement period comes.
-
SI
10 s
float
0~3.4*10^38
-
-
IntegrityEutranIpThr oughputCnt
count
The cumulated collection count of IpThru
This counter is calculated when measurement period comes.
-
SI
10 s
int
0~2147483647
-
-
IntegrityEutranIpLat encyTot
ms
The Sum of collected IpLateDI
This counter is calculated when measurement period comes.
-
SI
10 s
float
0~3.4*10^38
-
-
IntegrityEutranIpLat encyCnt
ms
The cumulated collection count of IpLateDI
This counter is calculated when measurement period comes.
-
SI
10 s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1232
Chapter 2 Counter Description
Availability This section provides statistics on the availability of an E-UTRAN cell.
Percentage of time that the cell is considered available. The elapsed time from the cell down due to the fault until its recovery. E-UTRAN Cell Availability CellAvaila bility
measuremen t_period - RRU.CellUnavailableT ime.[cause ] cause
measurement _ period
100
Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EutranCellAvail ability
%
The percentage of time that the cell is considered available
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(CellAvailPmPeriod TimeReadCellUnavailabl eTime)*100/CellAva ilPmPeriodTime
(sum(CellAvailPmPeri odTime)-sum(Read CellUnavailableTime)) *100/sum(CellAvailPm PeriodTime)
ReadCellUnava ilableTime
s
The number of disabled time per unit time
This counter is calculated when measurement period comes.
-
CC
1 min
int
0~60*Per iod
-
-
CellAvailPmPer
s
The data collection
This counter is calculated when
-
OW
Period
int
0~60*Per
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1233
Chapter 2 Counter Description Name iodTime
Unit
Description
Trigger
interval
measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
iod
Mobility This section provides statistics on the data that shows how E-UTRAN Mobility functionality is working.
Success rate of E-UTRAN mobility Mobility Success RateQCIx
HO.ExeSucc HO.PrepSucc.QCI QCIx 100% HO.ExeAtt HO.PrepAtt.QCIQCIx
The handover is calculated for each case to produce the KPI.
Intra eNB Handover X2 Handover Out X2 Handover In S1 Handover Out S1 Handover In Inter-RAT HPRD Handover HO.PrepAtt.QCI is calculated by HO.PrepSucc.QCI+HO.PrepFail.QCI. Index Name
Description
cNum
Cell Id
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1234
Chapter 2 Counter Description
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EutranMo bilityHoInt ra
%
The calculated HOIntra success rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoIntraSucc/ SumHoIntraAtt*10 0
sum(SumHoIntraSuc c)/sum(SumHoIntraAt t)*100
SumHoIn traAtt
count
The cumulated number of intra handover attempt count
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn traSucc
count
The cumulated number of intra handover execution success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn traPrepS ucc
count
The cumulated number of intra handover preparation success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
EutranMo bilityHoX 2Out
%
The calculated HOX2Out success rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoX2OutSuc c/SumHoX2OutAtt *100
sum(SumHoX2OutSu cc)/sum(SumHoX2Ou tAtt)*100
SumHoX 2OutAtt
count
The cumulated number of X2 handover attempt in SeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoX 2OutSucc
count
The cumulated number of X2 handover execution success in SeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoX 2OutPrep
count
The cumulated number of X2 handover preparation
This counter is calculated when measurement
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1235
Chapter 2 Counter Description Name
Unit
Succ
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
success in SeNB
period comes.
EutranMo bilityHoX 2In
%
The calculated HOX2In success rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoX2InSucc/ SumHoX2InAtt*10 0
sum(SumHoX2InSuc c)/sum(SumHoX2InAt t)*100
SumHoX 2InAtt
count
The cumulated number of X2 handover attempt in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoX 2InSucc
count
The cumulated number of X2 handover execution success in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoX 2InPrepS ucc
count
The cumulated number of X2 handover preparation success in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
EutranMo bilityHoS 1Out
%
The calculated HOIS1Out success rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoS1OutSuc c/SumHoS1OutAtt *100
sum(SumHoS1OutSu cc)/sum(SumHoS1Ou tAtt)*100
SumHoS 1OutAtt
count
The cumulated number of S1 handover attempt in SeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoS 1OutSucc
count
The cumulated number of S1 handover execution success in SeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoS 1OutPrep
count
The cumulated number of S1 handover preparation
This counter is calculated when measurement
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1236
Chapter 2 Counter Description Name
Unit
Succ
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
success in SeNB
period comes.
EutranMo bilityHoS 1In
%
The calculated HOS1In success rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoS1InSucc/ SumHoS1InAtt*10 0
sum(SumHoS1InSuc c)/sum(SumHoS1InAt t)*100
SumHoS 1InAtt
count
The cumulated number of S1 handover attempt in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoS 1InSucc
count
The cumulated number of S1 handover execution success in SeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoS 1InPrepS ucc
count
The cumulated number of S1 handover preparation success in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
EutranMo bilityHoInt erRatHrp d
%
The calculated HOInterRat success rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoInterRatHr pdSucc/SumHoInt erRatHrpdAtt*100
sum(SumHoInterRat HrpdSucc)/sum(Sum HoInterRatHrpdAtt)*1 00
SumHoIn terRatHrp dAtt
count
The cumulated number of Inter RAT Optimized HRPD handover attempt
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn terRatHrp dSucc
count
The cumulated number of Inter RAT Optimized HRPD handover execution success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn terRatHrp dPrepSuc
count
The cumulated number of Inter RAT Optimized HRPD handover
This counter is calculated when measurement
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1237
Chapter 2 Counter Description Name
Unit
c
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
preparation success
period comes.
EutranMo bilityHoInt erRatUtra nOut
%
The calculated HOInterRatUtranOut rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoInterRatUtr anOutSucc/SumH oInterRatUtranOut Att*100
sum(SumHoInterRat UtranOutSucc)/sum( SumHoInterRatUtran OutAtt)*100
SumHoIn terRatUtr anOutAtt
count
The cumulated number of LTE to Inter-RAT UTRAN handover attempt
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn terRatUtr anOutSu cc
count
The cumulated number of LTE to Inter-RAT UTRAN handover preparation failure
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn terRatUtr anOutPre pSucc
count
The cumulated number of LTE to Inter-RAT UTRAN handover preparation success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
EutranMo bilityHoInt erRatUtra nIn
%
The calculated HOInterRatUtranIn rate of E-UTRAN mobility
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
SumHoInterRatUtr anInSucc/SumHoI nterRatUtranInAtt* 100
sum(SumHoInterRat UtranInSucc)/sum(Su mHoInterRatUtranInA tt)*100
SumHoIn terRatUtr anInAtt
count
The cumulated number of Inter-RAT UTRAN to LTE handover attempt
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn terRatUtr anInSucc
count
The cumulated number of Inter-RAT UTRAN to LTE handover execution success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumHoIn terRatUtr anInPrep
count
The cumulated number of Inter-RAT UTRAN to LTE handover preparation
This counter is calculated when measurement
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1238
Chapter 2 Counter Description Name
Unit
Succ EutranMo bilityHoInt er
%
Description
Trigger
success
period comes.
The calculated probability that an end-user successfully completes a handover to a separate eNB of the same frequency
This counter is calculated when measurement period comes.
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Y
OW
Period
float
0~100
(SumHoS1OutSuc c+SumHoX2OutS ucc)/(SumHoS1O utAtt+SumHoX2O utAtt)*100
(sum(SumHoS1OutS ucc)+sum(SumHoX2 OutSucc))/(sum(Sum HoS1OutAtt)+sum(Su mHoX2OutAtt))*100
1239
Chapter 2 Counter Description
Success Rate This section provides statistics on the RRC success rate, ERAB success rate, and call drop rate are calculated based on the RRC, ERAB, CALL_DROP, and HO statistics collected.
Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
RrcEstabSu ccessRatio
%
The average success rate of RRC ESTAB
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(SumRrcEstabS uccess/SumRrc EstabAttempt)* 100
(sum(SumRrcEstabSu ccess)/sum(SumRrcE stabAttempt))*100
ErabEstabS uccessRatio
%
The average success rate of ERAB ESTAB
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(SumErabEstab Success/SumEr abEstabAttempt )*100
(sum(SumErabEstabS uccess)/sum(SumEra bEstabAttempt))*100
CallDropRati o
%
The average call drop rate
This counter is calculated when measurement period
Y
OW
Period
float
0~100
(SumCallDrop_ EccbDspAuditRl cMacCallReleas e+SumCallDrop _EccbRcvReset
((sum(SumCallDrop_E ccbDspAuditRlcMacC allRelease)+sum(Sum CallDrop_EccbRcvRe setRequestFromEcmb
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1240
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula RequestFromEc mb+SumCallDr op_EccbRcvCel lReleaseIndFro mEcmb+SumC allDrop_EccbRa dioLinkFailure+ SumCallDrop_E ccbDspAuditMa cCallRelease+S umCallDrop_Ec cbArqMaxRetra nsmission+Sum CallDrop_Eccb DspAuditRlcCall Release+SumC allDrop_EccbT moutRrcConnec tionReconfig+S umCallDrop_Ec cbTmoutRrcCo nnectionReesta blish+SumCallD rop_EccbS1Sct pOutOfService/ SumEstabInitSu ccNbr+SumInter X2InSucc+SumI nterS1InSucc+S umRatInSuccU TRAN)*100
Hourly, Daily, Monthly Formula )+sum(SumCallDrop_ EccbRcvCellReleaseI ndFromEcmb)+sum(S umCallDrop_EccbRad ioLinkFailure)+sum(Su mCallDrop_EccbDspA uditMacCallRelease)+ sum(SumCallDrop_Ec cbArqMaxRetransmiss ion)+sum(SumCallDro p_EccbDspAuditRlcC allRelease)+sum(Sum CallDrop_EccbTmout RrcConnectionReconfi g)+sum(SumCallDrop _EccbTmoutRrcConn ectionReestablish)+su m(SumCallDrop_Eccb S1SctpOutOfService)) /(sum(SumEstabInitSu ccNbr)+sum(SumInter X2InSucc)+sum(SumI nterS1InSucc)+sum(S umRatInSuccUTRAN) ))*100
-
CC
event
int
0~2147483 647
-
-
comes.
SumRrcEsta bAttempt
count
The cumulated number of RRC ESTAB attempt for each cell
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
This counter is calculated when measurement
1241
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
period comes. SumRrcEsta bSuccess
count
The cumulated number of RRC ESTAB success for each cell
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumErabEst abAttempt
count
The cumulated number of ERAB ESTAB attempt for each cell
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumErabEst abSuccess
count
The cumulated number of ERAB ESTAB success for each cell
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbDsp AuditRlcMac CallRelease
count
The cumulated number count that a call is released due to resource mismatch because the ECCB has remaining calls but the RLC and the MAC have no remaining calls.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbRcv ResetReque stFromEcmb
count
The cumulated number count that a call is released when a reset request is received from ECMB block due to
This counter is calculated when measurement period
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1242
Chapter 2 Counter Description Name
Unit
Description
Trigger
refork of a specific block in eNB.
comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
SumCallDro p_EccbRcv CellReleaseI ndFromEcm b
count
The cumulated number that a call is released when a Cell Release Ind message is received from ECMB block because of DSP down or CPRI failure caused by a problem in DSP.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbRadi oLinkFailure
count
The cumulated number that a call is released due to radio link failure.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbDsp AuditMacCal lRelease
count
The cumulated number that a call is released due to resource mismatch because the ECCB and the RLC have remaining calls but the MAC has no remaining calls.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbArq MaxRetrans mission
count
The cumulated number that a call is released when ARQ ACK is not received from the UE after the RLC performs as many transmission as the Max Retransmission to the UE.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro
count
The cumulated number
This counter
-
CC
event
int
0~2147483
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1243
Chapter 2 Counter Description Name
Unit
p_EccbDsp AuditRlcCall Release
Description
Trigger
that a call is released due to resource mismatch because the ECCB and the MAC have remaining calls but the RLC has no remaining calls.
is calculated when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
647
SumCallDro p_EccbTmo utRrcConne ctionReconfi g
count
The cumulated number that a call is released when the RRC Connection Reconfiguration Complete message is not received after the RRC Connection Reconfiguration message is sent.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbTmo utRrcConne ctionReesta blish
count
The cumulated number that a call is released when the RRC Connection Reestablishment Complete message is not received after the RRC Connection Reestablishment message is sent
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumCallDro p_EccbS1S ctpOutOfSer vice
count
The cumulated number that a call is released when the S1 Association’s status is changed from In Service to Out of Service.
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1244
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
SumEstabIni tSuccNbr
count
The cumulated number of ERAB ESTAB success for each cell
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumInterX2I nSucc
count
The cumulated number of X2 handover execution success for each cell in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumInterS1I nSucc
count
The cumulated number of S1 handover execution success for each cell in TeNB
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
SumRatInSu ccUTRAN
count
The cumulated number of Inter-RAT UTRAN to LTE handover execution success for each cell
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483 647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1245
Chapter 2 Counter Description
Connection Drop Rate This section provides statistics that indicate the ratio of abnormally terminated connections based on the number of created ERABs. Index Name
Description
cNum
Cell Id
mcID
Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI
QoS Class Identifier
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnDropRate
%
The calculated probability that an end-user abnormally looses an ERAB
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
CdrRelActiv e/(CdrSumE stabInitSucc Nbr+CdrEst abAddSucc Nbr)*100
sum(CdrRelActive)/ (sum(CdrSumEstab InitSuccNbr)+sum( CdrEstabAddSucc Nbr))*100
CdrSumEstabInit SuccNbr
count
The cumulated number of ERAB setup success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483647
-
-
CdrEstabAddSu ccNbr
count
The cumulated number of ERAB additional setup success
This counter is calculated when measurement period comes.
-
CC
event
int
0~2147483647
-
-
CdrRelActive
count
The cumulated number of bearers among active E-
This counter is calculated when
-
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1246
Chapter 2 Counter Description Name
Unit
Description
Trigger
RABs where a call is released due to abnormal operation in eNB.
measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
Cell Capacity This section provides statistics on the average simultaneous RRC Connected UE Load per Cell. Index Name
Description
cNum
Cell Id
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
ConnNoUEAvg
%
The average RRC Connection Capacity rate (%) per unit time
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(ConnNoRrc Avg/ConnMa xCallCount)* 100
(sum(ConnNoRrcAvg) /sum(ConnMaxCallCo unt))*100
ConnNoUEMax
%
The maximum RRC Connection Capacity rate (%) per unit time
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
-
max(ConnNoUEMax)
UsageNbrRbAvg
%
The average E-RAB Capacity rate (%) per unit time
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(UsageNbrEr ab/UsageMa xDrbCount)*1 00
(sum(UsageNbrErab)/ sum(UsageMaxDrbCo unt))*100
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1247
Chapter 2 Counter Description Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UsageNbrRbMax
%
The maximum ERAB Capacity rate (%) per unit time
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
-
max(UsageNbrRbMax )
ConnNoRrcAvg
count
The average RRC Connection per unit time
This counter is calculated when measurement period comes.
Y
GAUGE
2s
float
0~3.4*10^38
-
avg(ConnNoRrcAvg)
ConnMaxCallCou nt
count
The average available call count in the cell
This counter is calculated when measurement period comes.
Y
OW
Period
int
0~2147483647
-
avg(ConnMaxCallCou nt)
UsageNbrErab
count
The average number of E-RAB per unit time
This counter is calculated when measurement period comes.
Y
GAUGE
2s
float
0~3.4*10^38
-
avg(UsageNbrErab)
UsageMaxDrbCou nt
count
The average available number of E-RAB in the cell
This counter is calculated when measurement period comes.
Y
OW
Period
int
0~2147483647
-
avg(UsageMaxDrbCo unt)
CellCapacityConn NoRRCTot
count
The cumulated number of ConnNoAvg
This counter is calculated when measurement period comes.
Y
SI
2s
float
0~3.4*10^38
-
-
CellCapacityConn NoRRCCnt
count
The cumulated collection count of
This counter is calculated
Y
SI
2s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1248
Chapter 2 Counter Description Name
Unit
Description
Trigger
ConnNoAvg
when measurement period comes.
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
CellCapacityUsag eNbrERABTot
count
The cumulated number of UsageNbrAvg
This counter is calculated when measurement period comes.
Y
SI
2s
float
0~3.4*10^38
-
-
CellCapacityUsag eNbrERABCnt
count
The collection count of UsageNbrAvg
This counter is calculated when measurement period comes.
Y
SI
2s
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1249
Chapter 2 Counter Description
eNB Capacity This section provides statistics on the Average Simultaneous RRC Connected UE Load per eNB. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Trigger
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
EnbConnNo UEAvg
%
The average RRC Connection Capacity rate (%) per unit time
This counter is calculated when measurement period comes.
Y
OW
Period
float
0~100
(EnbConnNo RrcAvg/Enb MaxCallCou nt)*100
(sum(EnbConnN oRrcAvg)/sum(E nbMaxCallCount ))*100
EnbConnNo RrcAvg
count
The average RRC Connection per unit time
This counter is calculated when measurement period comes.
Y
GAUGE
2s
float
0~3.4*1 0^38
-
avg(EnbConnNo RrcAvg)
EnbMaxCall Count
count
The average available call count in eNB
This counter is calculated when measurement period comes.
Y
OW
Period
int
0~21474 83647
-
avg(EnbMaxCall Count)
EnbCapacity eNBConnNo RRCTot
count
The cumulated number of ConnNoAvg
This counter is calculated when measurement period comes.
-
GAUGE
2s
float
0~3.4*1 0^38
-
-
EnbCapacity eNBConnNo RRCCnt
count
The cumulated collection count of ConnNoAvg
This counter is calculated when measurement period comes.
-
GAUGE
2s
int
0~21474 83647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1250
Chapter 2 Counter Description
UE Category UE Category This section provides statistics on the number of UE for each UE Category. The eNB performs a count by category of EMM-Registered UE. Index Name
Description
-
-
Statistics Type Name
Unit
Description
Visible
Counter Type
Trigger Type
Data Type
Min/Max
Granularity Formula
Hourly, Daily, Monthly Formula
UECategory1
count
The number of UE for UECategory 1
Y
CC
event
int
0~2147483647
-
-
UECategory2
count
The number of UE for UECategory 2
Y
CC
event
int
0~2147483647
-
-
UECategory3
count
The number of UE for UECategory 3
Y
CC
event
int
0~2147483647
-
-
UECategory4
count
The number of UE for UECategory 4
Y
CC
event
int
0~2147483647
-
-
UECategory5
count
The number of UE for UECategory 5
Y
CC
event
int
0~2147483647
-
-
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
1251
Appendix A Acronyms AP ARQ AVG BH BHCAC BLER CAC CALLRSC CDMA CLI CPRI CQI CQIRSC CRC CS CSFB CSL DCCH DLUL DRB DRX DSCH DSP DTCH DTX EARFCN ECMB EMS ENB EPC EPS ERAB ETWA EUTRA EUTRAN GBR GPRS GTP GTPB GW
Application Automatic Repeat Request Average Backhaul Backhaul Call Admission Control Block Error Rate Call Admission Control Call Resource Code Division Multiple Access Command Line Interface Common Public Radio Interface Channel Quality Indicator Channel Quality Indicator Resource Cyclic Redundancy Check Circuit Switched Circuit Switched Fallback Call Summary Log Dedicated Control Channel Downlink and Uplink Data Radio Bearer Discontinuous Reception Downlink Shared Channel Digital Signal Processing Dedicated Traffic Channel Discontinuous Transmission E-UTRA Absolute Radio Frequency Channel Number ENB Call Control Block Element Management System E-UTRAN NodeB Evolved Packet Core Evolved Packet System E-UTRAN Radio Access Bearer Earthquake and Tsunami Warning service Evolved-Universal Terrestrial Radio Access Evolved UTRAN Guaranteed Bit Rate General Packet Radio Services GPRS Tunneling Protocol GTP Block Gateway
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Appendix A Acronyms
HARQ HC HFN HRPD IP KPI LBHO LSM LTE MAC MACB MCS MIMO MLB MME MRO MSGID NACK NAS OAM OOS OW PAG PDCB PDCCH PDCP PDN PDSCH PDU PHY PLD PLMN PMI PRB PUSCH QCI QOS RA RAB RACH RB RBID RCL RLC
Hybrid ARQ High Capability Hyper Frame Number High Rate Packet Data Internet Protocol Key Performance Indicators Load Balancing Handover LTE System Manager Long Term Evolution Medium Access Control Medium Access Control Block Modulation and Coding Scheme Multiple Input Multiple Output Mobility Load Balancing Mobility Management Entity Mobility Robustness Optimization Message ID Negative Acknowledgement Non Access Stratum Operating And Management Out Of Service Overwrite Paging Packet Data Control Block Physical Download Control Channel Packet Data Convergence Protocol Packet Data Network Physical Downlink Shared Channel Packet Data Unit Physical Programmed Loadable Data Public Land Mobile Network Precoding Matrix Indicator Physical Resource Block Physical Uplink Shared Channel QoS Class Identifier Quality Of Service Radio Access Radio Access Bearer Random Access Channel Resource Block Resource Block ID Routing Control Layer Radio Link Control
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Appendix A Acronyms
RLCB RLF RNC RNTI RNTP RRC RRH RRM RRU RSP RSSI SAE SCTP SDU SGSN SLR SRB STMSI TA TB TMSI TS TTI TTI UE UL UTRAN VPN WEEE
Radio Link Control Block Radio Link Fail Radio Network Controller Radio Network Temporary Identifier Relative Narrowband TX Power Radio Resource Control Remote RF Header Radio Resource Manager Remote RF Unit RNC Switch control Processor Received Signal Strength Indicator System Architecture Evolution Stream Control Transmission Protocol Service Data Unit Serving GPRS Support Node Samsung LTE Release Signaling Radio Bearer SAE Temporary Mobile Subscriber Identity Timing Alignment Transport Block Temporary Mobile Station Identify Technical Specification Transmission Time Interval Transmission Time Interval User Equipment Uplink UMTS Terrestrial Radio Access Network Virtual Private Network Waste Electrical and Electronic Equipment
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Appendix B Index Range Explains the index used for each counter. Parameters
Value Range
Description
MAX
MIN
BID
2
0
Board Id
CallDropEstab Cause
6
0
RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: delay_tolerant_access: Access by the delay tolerant access 6: relocated: Access by the UE due to handover
Cascade
0
0
Cascade ID
cNum
255
0
Cell Id
codeword
1
0
Codeword (Transport block count) 0: First transport block 1: Second transport block
cos
7
0
Class of Service
CSFBIndicator
1
0
CSFB Indicator 0: Normal 1: High priority
DL Layer
4
1
Layer (data stream count) 1: 1 stream 2: 2 stream 3: 3 stream 4: 4 stream
EstabCause
5
0
RRC Connection Establishment Cause 0: emergency (Emergency call connection) 1: highPriorityAccess (Access by the UE with a specific access class) 2: mt_Access (Access by the UE due to paging received) 3: mo_Signaling (Access by the UE due to attach) 4: mo_Data (Access by the UE due to service request) 5: delay_tolerant_access (Access by the delay tolerant access)
HistogramBin
9
0
Bin index of Histogram
HOCause
1
0
Handover Cause 0: Handover desirable for radio reasons 1: reserved
HOIndication
1
0
Upon performing the handover Information on classifying PS_CS, and CS_only
LEVEL
9
0
IOT Level
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Appendix B Index Range Parameters
Value Range
Description
MAX
MIN
mcID
35
0
Subcell Index (displayed only for smart cell configuration; included in the statistics)
mepId
8191
1
CFM Mep Id
NeighborCell
268435455
0
The identifier of NeighborCell which is the target of the handover problem (Cell Identity)
pcID
268435455
0
PartnerCell ID
PktPerSec
20000
1
Packets per second
PktSize
8206
83
The test packet size of TWAMP Test.
PLMN
268435455
0
PLMN Id; mcc in the first three-digit numbers and mnc after the three-digit numbers
QCI
255
0
QoS Class Identifier
QCI_SPECIFI C
3
0
0: QCI_1, 1: QCI_5, 2: QCI_8, 3: QCI_9
ReEstabCause
3
0
RRC Connection Re-establishment Cause 0: reconfigurationFailure (Re-establishment occurs due to reconfiguration failure) 1: handoverFailure (Re-establishment occurs due to handover failure) 2: otherFailure (Re-establishment occurs due to other failures) 3: reserved
rmepId
8191
1
CFM Remote Mep Id
RncID
4095
0
RNC ID
RRC_QCI_SP ECIFIC
4
0
0: NO_QCI, 1: QCI_1, 2: QCI_5, 3: QCI_8, 4: QCI_9
RSSIPath
7
0
RSSI Path ID
RuPort
5
0
Ru Port Number
scID
268435455
0
Source Cell Id
SIBOwn
1
0
Indicates whether UTRAN SI information is included. 0: Not Included 1: Included
SlotId
6
0
The ID of the slot where the board is mounted.
status
2
0
0: ACK, 1: NACK, 2: DTX
Step
3
1
Load Balancing Handover Triggering Step 1: LBHO within the same group and sector 2: LBHO between different groups but the same sector (the same eNB) 3: LBHO between different sectors
TargetEarfcnDl
268435455
0
target Neighbor Cell Frequency (EARFCN DL)
tcID
268435455
0
Target Cell Id
UtranCellID
268435455
0
UTRAN Cell ID
VlanId
268435455
0
dbIndex in the VlanConf PLD
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Appendix B Index Range
The constant in the formula are calculated as follows: Constant
Description
Value
K_UNIT
The constant value used in the unit conversion in the packet (Kbyte byte)
1000
M_UNIT
The constant value used in the unit conversion in the packet (Mbyte byte)
1000*1000
Samsung eNB Counter Description for SLR 4.5 v7.0 © Samsung Proprietary and Confidential
Samsung eNB Counter Description for SLR 4.5 Document Version 7.0 © 2015 Samsung Electronics Co., Ltd. All rights reserved.