3.2 Guide Hadware Installation

  • Uploaded by: Mitch Harris
  • 0
  • 0
  • February 2021
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View 3.2 Guide Hadware Installation as PDF for free.

More details

  • Words: 3,784
  • Pages: 21
Loading documents preview...
Smartfren LTE Expansion Project Key installation guide No

When

What

Who

Planning & Preparation

1- Permit 2- Key 3- DP, CAF 4- WAH Certificate, Training certificate. 5- Checking Installation Tools, Safety PPE, and vehicle 6- Site Address, rout and contact details

Subcon Team Leader, Coordinator

MOS

1- Check all Material Items according to DN & Site BOM in DP 2- Any missing Item should be write on DN Receiving note & Escalate to ZTE 3- Ensure HSE Compliance, No Safety PPE - No Work!! Mandatory- Safety Harness, Safety helmet, Safety Shoes, Safety Gloves

Subcon Team Leader

3

Installation

1- Ensure pre labelling of RRU optical, RRU power & RF Jumper cables first. 2- Team Finish WIP check report using Site Manager. 3- Ensure Working in allowed area. 4- Ensure Team follow Site Design and Installation Standard Subcon Team 5- Any misunderstanding , question about solution, work etc Leader contact ZTE Engineer. 6- Any exception from design and site standards must take written approval from ZTE before process installation. 7- Report any incident from Site.

4

1- Subcon Do Power on Commissioning, and integration of Commissioning Integration equipments. and CA 2- Check with OMC that there is no Alarm. 3- Ensure no cross fiber connection among sectors.

3

1- Team leader do Quality Self check using ZTE Site Manager after all work complete. Subcon After Finish Installation & 2- Team leader coordinate with ZTE EPMS Review team to make Engineer/Team CA sure self check accepted. Leader 3- Without Self check completed , Team not allowed to leave Site.

1

2

Subcon Engineer

This guide only cover key installation points. For complete guide and standards please contact Quality Manager Rajesh- [email protected] Lukman-081231349595 PT.ZTE INDONESIA Andi-081384234840

Page 1

Model 1-1 :TDD 8T8R with 8 port ANT and without PS No.

BBU Material

Amount

No.

RRU & ANT Material

Amount

1

B8200 Frame

1

1

R8978

3

2

CCE1B

1

2

Rosenberger BA-4Q7X90V-00

3

3

BPN2

1

3

Rosenberger SBT

3

4

CR0

0

4

Rosenberger AISG cable

3

5

PM3

1

5

R8862A

0

6

SA

1

6

Filter

0

Model 1-2 :TDD 8T8R with 8 port ANT and with PS (ZXDU48 H002 WR12) No.

BBU Material

Amount

No.

RRU & ANT Material

Amount

1

B8200 Frame

1

2

CCE1B

1

1

R8978

3

2

Rosenberger BA-4Q7X90V-00

3

3

BPN2

1

4

CR0

0

3

Rosenberger SBT

3

4

Rosenberger AISG cable

3

5

PM3

6

SA

1

5

R8862A

0

1

6

Filter

0

Model 2-1 :TDD 8T8R+FDD 2T2R with 10 port ANT and without PS No.

BBU Material

Amount

No.

RRU & ANT Material

Amount

1

B8200 Frame

1

1

R8978

3

2

CCE1B

1

2

Rosenberger BA-4Q7X90V-00

3

3

BPN2

2

3

Rosenberger SBT

3

4

CR0

1

4

Rosenberger AISG cable

3

5

PM3

2

5

R8862A

3

6

SA

1

6

Filter

3

Model 2-2 :TDD 8T8R+FDD 2T2R with 10 port ANT and with PS (ZXDU48 H002 WR12) No.

BBU Material

Amount

No.

RRU & ANT Material

Amount

1

B8200 Frame

1

2

CCE1B

1

1

R8978

3

2

Rosenberger BA-4Q7X90V-00

3

BPN2

3

2

3

Rosenberger SBT

4

1

CR0

1

4

Rosenberger AISG cable

1

5

PM3

2

5

R8862A

3

6

SA

1

6

Filter

3

Model 3-1 :TDD 8T8R+FDD 2T4R with 12 port ANT and with PS (ZXDU68 W201) No.

BBU Material

Amount

No.

RRU & ANT Material

Amount

1

B8200 Frame

1

2

CCE1B

1

1

R8978

3

2

Rosenberger BA-4Q7X90V-00

3

3

BPN2

2

4

CR0

1

3

Rosenberger SBT

3

4

Rosenberger AISG cable

5

PM3

3

2

5

R8862A

3

6

SA

1

6

Filter

3

Model 3-2 :TDD 8T8R+FDD 2T4R with 2 Separated and with PS (ZXDU68 W201) No.

BBU Material

Amount

No.

RRU & ANT Material

Amount

1

B8200 Frame

1

1

R8978

3

2

CCE1B

1

2

Rosenberger BA-4Q7X90V-00

3

3

BPN2

2

3

Rosenberger SBT

3

4

CR0

1

4

Rosenberger AISG cable

3

5

PM3

2

5

R8862A

3

6

SA

1

6

Filter

3

7

LDXX-6515DS-VTM

3

7

ATM200-A20 (RET Motor)

6

PT.ZTE INDONESIA

Page 5

BBU 8200 Scenario:TDD Only

BBU 8200 Scenario:TDD +FDD

PM3

BPN2 TDD

PM3

CR0

SA

CCE1B

CCE1B

SA

BPN2 TDD

BPN2 FDD

CCE1B

Optical Port

BPN2:

SECTOR2

Electric Port SECTOR3

SECTOR1

TDDRRU(R8978 S2300):

OPT2 OPT1

Ant 8

Ant 7

Ant 6

Ant 5

Ant 4

Ant 3

Ant 2

Ant-1

PWR

CAL/AISG

GND

CONNECTION: CASE1(TDD 8T8R Only)

FDDRRU(R8862A):

To PDCP

To Transmission equipment

R8978 AISG/CAL

CONNECTION:CASE2(TDD 8T8R and FDD 2T2R) Option-1 With SBT

Option-2 No SBT

To PDCP

To PDCP

SBT

To Transmission equipment

C A L

To Transmission equipment

R8978

R E T

8 Port Antenna

R8978 R8862A

AISG/CAL

R8862A

CAL R E T

SBT

Filter

Filter

C A L

C A L

R E T

10 Port Antenna

R E T

10 Port Antenna

CONNECTION:CASE3(TDD 8T8R and FDD 2T4R) Option-1(With SBT) To PDCP

Option-2(No SBT) To PDCP

To Transmission equipment

To Transmission equipment

R8978

R8978 AISG/CAL

R8862A

R8862A

CAL R E T

SBT Filter Filter

C A L

R E T

12 Port Antenna

PT.ZTE INDONESIA

C A L

R E T

12 Port Antenna

Page 2

Model 1-1 :TDD 8T8R with 8 port ANT and without PS

Connection jumper At antenna 8 port

Marking Colour insulation tape Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 1 Port 7 Yellow ring 3 blue ring 1 Port 8 Yellow ring 4 blue ring 1

Rosenberger BA-4Q7X90V-00 AISG

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

2300-2400 MHz -45°

IN

OUT

RET CALL

2300-2400 MHz +45°

4

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

2300-2400 MHz +45°

8

SBT

Jumper cablle connection

Cable power RRU to DCPD

R8978 ANT1

ANT2

ANT3

ANT4

ANT5 ANT6

Power PM3 to DCPD BALI TOWER

Optic cable Connection from RRU To BPN

Opt1

CCE1B

PM3

ANT8

ZXSDR8978

AISG

-48V-48VRTN

ANT7

BPN2 Board on Slot 8 ESD

SA

GND RRU

Opt3 Opt2 Opt1

DEBUG

Busbar

BPN2 Transmission (LAN Cable)

Remark :

Squence slot module BBU B8200 GPS

Transmission (Opt Cable) Antenna GPS

Model 1-2 :TDD 8T8R with 8 port ANT and without PS (ZXDU48 H002 WR12)

Connection jumper At antenna 8 port

Marking Colour insulation tape Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 1 Port 7 Yellow ring 3 blue ring 1 Port 8 Yellow ring 4 blue ring 1

Rosenberger BA-4Q7X90V-00 AISG

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

2300-2400 MHz -45°

IN

OUT

RET CALL

2300-2400 MHz +45°

4

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

2300-2400 MHz +45°

8

SBT

Jumper cablle connection

Cable power RRU to DCPD

R8978

Cable power RRU to DCPD ANT1

ANT2

ANT3

ANT4

ANT5 ANT6

Power Connect MCB 1 TDD1 MCB 2 TDD2 MCB 3 TDD3 MCB 4 FDD1 MCB 5 FDD2 MCB 6 FDD3 MCB 7 BBU

PM3

Opt1

ANT8

ZXSDR8978

AISG

-48V-48VRTN

ANT7

Optic cable Connection from RRU To BPN

CCE1B

BPN2 Board on Slot 8

ESD SA

Opt3 Opt2 Opt1

DEBUG

GND RRU Busbar

BPN2 Transmission (LAN Cable)

Squence slot module BBU B8200 GPS

Transmission (Opt Cable) Antenna GPS

PT.ZTE INDONESIA

Page 6

Model 2-1 :TDD 8T8R+FDD 2T2R with 10 port ANT and without PS jumper FDD Marking Colour insulation tape AISG

Port 1 Red 1 Port 2 Red 2 Port 3 Red 3 Port 4 Red 4

ZXSDR8862A

ANT1

Cable power RRU FDD to DCPD

ANT2

ANT3

ANT4

Opt1

R8862 FDD RRU

FILTER

antenna 10 port 810-890 MHz +45°

Rosenberger BA-4Q7X90V-00

810-890 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

2300-2400 MHz -45°

RET

2300-2400 MHz +45°

2300-2400 MHz +45°

4

5

2300-2400 MHz +45°

2300-2400 MHz +45°

6

7

8

SBT

Jumper cablle connection

Bias T

Power Connect MCB 1 POWER PM1 MCB 2 TDD1 MCB 3 TDD2 MCB 4 TDD3 MCB 5 POWER PM 2 MCB 6 FDD1 MCB 7 FDD2 MCB 8 FDD3

Jumper TDD Marking Colour insulation tape Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 1 Port 7 Yellow ring 3 blue ring 1 Port 8 Yellow ring 4 blue ring 1

R8978 TDD RRU

Cable power RRU TDDto DCPD ANT1

ANT2

ANT3

ANT4

ANT5 ANT6

ANT7

ANT8

ZXSDR8978

AISG

Opt1

-48V PM3 -48VRTN

Optic cable Connection from RRU To BPN

CR0

Power PM3 to DCPD BALI TOWER

CCE1B SA

ESD

Slot 8 For TDD Slot 6 For FDD

DEBUG

GND RRU

Opt3 Opt2 Opt1

Busbar

BPN2 Transmission (LAN Cable)

Squence slot module BBU B8200 GPS

Transmission (Opt Cable) Antenna GPS

Model 2-2 :TDD 8T8R+FDD 2T2R with 10 port ANT and with PS ZXDU48 H002 WR12

jumper FDD Marking Colour insulation tape

AISG

ZXSDR8862A

ANT1

Cable power RRU FDD to DCPD

ANT2

ANT3

ANT4

Opt1

Rosenberger BA-4Q7X90V-00

R8862 FDD RRU

FILTER

antenna 10 port

1

2

810-890 MHz +45°

810-890 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

3

4

810-890 MHz +45°

2300-2400 MHz -45°

RET

2300-2400 MHz +45°

4

810-890 MHz -45°

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

2300-2400 MHz +45°

7

8

SBT

Jumper cablle connection

Bias T

ANT2

ANT3

ANT4

ANT8

Opt1 Optic cable Connection from RRU To BPN

-48V

PM3 -48VRTN CR0 CCE1B

SA

Slot 8 For TDD Slot 6 For FDD

DEBUG

ESD Opt3 Opt2 Opt1

GND RRU Busbar

BPN2

ZXDU48 H002

Remark :

ANT7

ZXSDR8978

AISG

Power Connect MCB 1 TDD1 MCB 2 TDD2 MCB 3 TDD3 MCB 4 FDD1 MCB 5 FDD2 MCB 6 FDD3 MCB 7 BBU MCB 8 BBU

ANT5 ANT6

Jumper TDD Marking Colour insulation tape Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 1 Port 7 Yellow ring 3 blue ring 1 Port 8 Yellow ring 4 blue ring 1

R8978 TDD RRU

Cable power RRU TDDto DCPD ANT1

Port 1 Red 1 Port 2 Red 2 Port 3 Red 3 Port 4 Red 4

Squence slot module BBU B8200

Transmission

GPS Transmission Antenna GPS

PT.ZTE INDONESIA

Page 7

Model 3 :TDD 8T8R+FDD 2T4R with 12 port ANT and with PS ZXDU68 w201

jumper FDD Marking Colour insulation tape

AISG

Cable power RRU FDD to DCPD

Port 1 Red 1 Port 2 Red 2 Port 3 Red 3

ZXSDR8862A

ANT1

ANT2

ANT3

ANT4

R8862 FDD RRU

Opt1

antenna 12 port

FILTER

Jumper TDD Marking Colour insulation tape Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 1 Port 7 Yellow ring 3 blue ring 1 Port 8 Yellow ring 4 blue ring 1

Rosenberger BA-4Q7X90V-00

1

3

2

810-890 MHz +45° 2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

4

810-890 MHz +45°

810-890 MHz -45° 2300-2400 MHz -45°

RET

2300-2400 MHz +45°

4

810-890 MHz -45°

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

2300-2400 MHz +45°

8

SBT

Jumper cablle connection

Bias T

R8978 TDD RRU

Cable power RRU TDDto DCPD ANT1

Power Connect MCB 1 PM1 MCB 2 PM2 MCB 3 TDD1 MCB 4 TDD2 MCB 5 TDD3 MCB 6 FDD1 MCB 7 FDD2 MCB 8 FDD3 BLVD for eguard transmition, Fan

ANT2

ANT3

ANT4

ANT5 ANT6

ANT8

ZXSDR8978

AISG

PM3 -48VRTN -48V

ANT7

Opt1

Optic cable Connection from RRU To BPN

CR0 CCE1B

SA

ESD

Slot 8 For TDD Slot 6 For FDD

DEBUG

GND RRU

Opt3 Opt2

Opt1

Busbar

BPN2 Transmission (LAN Cable)

Squence slot module BBU B8200 GPS

Transmission (Opt Cable) Antenna GPS

Model 3 :TDD 8T8R+FDD 2T4R with 2 separate ANT and with PS ZXDU68 W201

Jumper TDD Marking Colour insulation tape Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 1 Port 7 Yellow ring 3 blue ring 1 Port 8 Yellow ring 4 blue ring 1

jumper FDD Marking Colour insulation tape Port 1 Red 1 Port 2 Red 2 Port 3 Red 3

LDXX-6515DS-VTM L-790-960 MHz +45°

L-790-960 MHz -45°

R-790-960 MHz +45°

Rosenberger BA-4Q7X90V-00 R-790-960 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

2300-2400 MHz -45°

RET

2300-2400 MHz +45°

4

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

2300-2400 MHz +45°

8

SBT

ANT A

ANT B Filter

Node A

R8978 TDD RRU

Node B

ANT1

ANT2

ANT3

ANT4

AISG

R8862 FDD RRU

ANT5 ANT6

ANT7

ANT8

ZXSDR8978

ANT1 ANT2 ANT3 ANT4

R8862A Optic Power Cable Cable RRU

ZXDU68 W201 DEBUG

Slot 8 For TDD Slot 6 For FDD

Opt3 Opt2

Opt1

Transmission

Transmission Antenna GPS

PT.ZTE INDONESIA

Page 8

Antenna Installation Antenna mounting bracket installed with washer, lock washer and double nuts

Orientation as per plan – checked by compass

Tilt Should be as per plan checked by tilt meter

TDD RRU

Fix with black ties length waterproofing 13cm

Height of Antenna As per Design pack and CAF

Fix with black ties

Labeling with same direction

FDD RRU

Jumpers of each antenna connected at correct ports.  Waterproofing at antenna ports is as per standards, (+3 layer +3 layers + 3 layers mode)  At the antenna connectors, the jumper shall keep 300mm straight.  Labeling of each jumper at both ends (200mm away from connectors)

Antenna mounting bracket installed with washer, lock washer and double nuts

FILTER

BIAS T

Antenna must be installed within the 45° protection scope of the lightning rod.

PT.ZTE INDONESIA

Page 9

Jumper connection Antenna 8 Port with SBT only for TDD

Color Labeling TDD Port 1 Yellow ring 1 Port 2 Yellow ring 2 Port 3 Yellow ring 3 Port 4 Yellow ring 4 Port 5 Yellow ring 1 blue ring 1 Port 6 Yellow ring 2 blue ring 2 Port 7 Yellow ring 3 blue ring 3 Port 8 Yellow ring 4 blue ring 4

RET 2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

OUT

2300-2400 MHz -45°

IN

CALL

2300-2400 MHz +45°

2300-2400 MHz +45°

4

5

2300-2400 MHz +45°

2300-2400 MHz +45°

6

7

8

SBT

FDD Port 1 Red 1 Port 2 Red 2 Port 3 Red 3 Port 4 Red 4 Need isolation tape 3 Color TDD Yellow and Blue

Antenna 12 Port ANT1

ANT2

ANT3

ANT4

ANT5 ANT6

ANT7

ANT8

ZXSDR8978

AISG

Optic Power Cable Cable RRU

Antenna 8 Port without SBT only for TDD

Antenna 8 Port RET 2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

2300-2400 MHz -45°

OUT

4

IN

CALL

2300-2400 MHz +45°

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

2300-2400 MHz +45°

8

FDD RRU

ANT1

TDD RRU

AISG

ANT2

ANT3

ANT4

ANT5 ANT6

ANT7

ANT8

ZXSDR8978

Optic Power Cable Cable RRU

PT.ZTE INDONESIA

Page 4

Antenna 10 Port without SBT for TDD and FDD

Antenna 10 Port with SBT for TDD and FDD Power Optic Cable Cable RRU

Power Optic Cable Cable RRU

AISG ANT1

AISG

ZXSDR8862A ANT2

ANT3

ANT4

ANT1

FILTER

810-890 MHz +45° 2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

ANT3

ANT4

FILTER

810-890 MHz -45°

2300-2400 MHz -45°

ZXSDR8862A ANT2

810-890 MHz +45°

RET 2300-2400 MHz -45°

OUT

IN CALL

2300-2400 MHz +45°

4

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

2300-2400 MHz +45°

8

810-890 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

RET 2300-2400 MHz -45°

OUT

IN CALL

2300-2400 MHz +45°

4

2300-2400 MHz +45°

5

6

2300-2400 MHz +45°

7

SBT

ANT1

ANT2

ANT3

AISG

Optic Power Cable Cable RRU

PT.ZTE INDONESIA

ANT4

ANT5 ANT6

ANT7

ANT1

ANT8

AISG

ZXSDR8978

ANT2

ANT3

ANT4

ANT5 ANT6

ANT7

ANT8

ZXSDR8978

Optic Power Cable Cable RRU

Page 4

2300-2400 MHz +45°

8

Antenna 12 Port without SBT for TDD and FDD

Antenna 12 Port with SBT for TDD and FDD Power Optic Cable Cable RRU

Power Optic Cable Cable RRU

AISG

AISG

ZXSDR8862A

ANT1

ANT2

ANT3

ANT4

ZXSDR8862A

ANT1

ANT2

FILTER

1

2

810-890 MHz +45°

810-890 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

ANT3

ANT4

FILTER

RET

2300-2400 MHz -45°

OUT

IN RET

4

3

4

1

2

3

4

810-890 MHz +45°

810-890 MHz -45°

810-890 MHz +45°

810-890 MHz -45°

810-890 MHz +45°

810-890 MHz -45°

2300-2400 MHz +45°

2300-2400 MHz +45°

2300-2400 MHz +45°

2300-2400 MHz +45°

5

6

7

8

2300-2400 MHz -45°

2300-2400 MHz -45°

2300-2400 MHz -45°

1

2

3

RET

2300-2400 MHz -45°

IN

OUT RET

2300-2400 MHz +45°

2300-2400 MHz +45°

2300-2400 MHz +45°

2300-2400 MHz +45°

5

6

7

8

4

SBT

4 port antenna LDXX for ANT1 ANT2 ANT3 ANT4 ANT5 ANT6 ANT7 FDD Only AISG

Optic Power Cable Cable RRU

PT.ZTE INDONESIA

ANT8

ANT1

ZXSDR8978

AISG

ANT2

ANT3

ANT4

ANT5 ANT6

ANT7

ANT8

ZXSDR8978

Optic Power Cable Cable RRU

Page 4

Antenna 4 Port For FDD and RET ( ATM 200 ) Connection

L-790-960 MHz +45°

L-790-960 MHz -45°

ANT A

R-790-960 MHz +45°

R-790-960 MHz -45°

Connection ATM 200

ANT B Filter

Node A

Node B

RET ATM 200

R8862A ANT1 ANT2 ANT3 ANT4

R8862A

ATM 200 RET AISG CABLE

HOW TO CONNECT ATM 200 TO ANTENNA

PT.ZTE INDONESIA

Page 4

Installation Optic cable . Please make sure Cover the Head of LC Connector to Prevent any Damage

- Push through the fiber cable inside the metal conduit until the required length

35cm - Combined 3 Fiber Cable As Shown in the Picture and make sure there is Support ( wood, metal ) below it to secure the fiber for any damage

- TDD Fiber and FDD Fiber Separate metal Conduit All Fiber Cable Horizontal Run Must Install with The metal Conduit For Vertical Run Only 1m

OPT1

Print Label

Plastic Label

2cm

20cm

Opt cable connect to BPN Port

Opt cable connect to OPT1 RRU To BPN Port

Laying New Cable Optic at Tray Vertical and Fixing with Clamp 1mtr – 1,5mtr

- Ensure Optic cable already have Temporary Label End to end , Red Insulation For FDD, Yellow Insulation For TDD

To OPT 1 RRU

1. if outdoor optical cable is longer than expected. Put one top on leg of tower,bind the remained opticalcable into circles whose diameter ranges from 30cm to 40 cm and then fasten the cable coil to the pole. 2. Use metal ties ( less then 10 meters ), the coil for each sector should be placed separate. 3. Excess optic holder will be used when the excess optic cable length more than 10 mts, one optic holder for one site

PT.ZTE INDONESIA

Page 10

ZXSDR R8978 TDD 8 Path Remote Radio Unit 1. Radiating pin 2. Handle 3. LED indicators 4. Operation and maintenance cavity 5. Antenna interface 6. CAL/AISG interface 7. Grounding bolt 8. Breathable valve 9. EAM/RGPS interface

Recommended Installation Space (Unit: mm)

External Cable Connection

Connection of the Protective Grounding Cable

Connection of the Antenna Feeder Interface Cable

Installing an RRU

Structure of the Power Connector

Fixing the Cable Clip

1. Button 2. Loop insulator 3. Top 4. Cable-pressing slot 5. External body

RRU CLAMP Fastening-plate bolt installation Special Note: Smartfren request additional nut for RRU fixing bracket bolt Nut 1 Nut 2

PT.ZTE INDONESIA

Page 12

Power connection at RRU Tube terminal diameter according to the cross-section area of the power cable.

Tube terminals

crimping of terminal perfect

Standard for RRU power cable R8978 ( TDD RRU ) Installation Qty. of R8978

R8862A ( FDD RRU ) Installation Qty. of R8862A

RRU grounding •

• •

Lugs of PGND cable made properly at both ends and cable is connected from the grounding point of RRU to ground bar. Each cable at ground bar connected independently. RRU Ground bar is connected with site main ground bar.

PT.ZTE INDONESIA

RRU Power cable entry waterproof rubber plug used at cable entry.

Power cable shield grounding should be connected properly at power cable grounding terminal.

GPS Installation

• • • • • • • •

Installation position of GPS antenna as per standard design. GPS shall be fixed at 300mm distance from tower. Fixing of GPS surge arrester in GPS panel shall be tight. GPS antenna shall be fixed with bracket firmly. Both end connectors of 1/4"feeder cable shall be made perfect as per standard process. Hot Shrinkable tube/insulation tape should be installed on connectors. ¼” feeder cable must be grounded near the feeder window of the equipment room, grounding clip must be connected to ground bar reliably, the direction of grounding clip wire shall be towards ground bar. Position of a cable where a grounding clamp is applied must be processed with the “1-3-3” water-proof measure, that is, one-layer insulating adhesive tape, three-layer waterproof adhesive tape, and three-layer ultraviolet-proof adhesive tape.

GPS connectivity with BBU

SMA cable connected to CH1 port of GPS Surge arrester

+ 300mm SMA cable fixing at CC Board

GPS ¼” jumper connector made-up method

PT.ZTE INDONESIA

Placement and connection BBU B8200 at Bali tower cabinet

Antenna

1 2 3 4

5 6 7 8

BALI TOWER CABINET RACK RRU

SECTOR2

BBU

SECTOR3

GPS PENAL TRAY

DC Power

Optic cable RRU

SECTOR1

BPN2

PM3 PM3 SA

BPN2

TDD

BPN2

FDD

FAM

CR0 CCE

SEMIRIGIDE GPS CABLE

ARESTER GPS

ESD CABLE

GPS PENAL TRAY

Placement and connection BBU B8200 at ZXDU48 H002 & ZXDU68 W201 ZXDU48 H002 WR12

1

2

ZXDU68 W201

1

PT.ZTE INDONESIA

2

3 4 5 6

Page 11

ZXDU48 H002(V5.0)Outdoor DC PS Single phase (1 Phase)

PT. ZTE INDONESIA

**Koneksi kabel power 1 phase dari ACPDB box ke AC Input rectifier

PT. ZTE INDONESIA

MODEL >>> 2

PT. ZTE INDONESIA

ZXDU68 W201 Outdoor DC PS Three phase (3 Phase) *Koneksi kabel power 3 phase dari ACPDB box ke AC Input rectifier

Netral Phase R Phase S Phase T

BOX ACPDB

PT. ZTE INDONESIA

LLVD1

BLVD

Power PM1

MW

Power PM2 TDD 1,2,3

FDD 1,2,3

-48 V Connection with label

PT. ZTE INDONESIA

Eguard

TEC FAN

-48 VRTN Connection with label

Related Documents


More Documents from "Jack Gerrard"