Test Report issued under the responsibility of:

www.tuv.com

TEST REPORT IEC 62109-1 Safety of power converters for use in photovoltaic power systems – Part1: General requirements Report Reference No. ...................... : Tested by (name + signature) .......... : Witnessed by (name + signature) .... : Supervised by (name + signature) ... : Approved by (name + signature) ...... : Date of issue ..................................... : Testing Laboratory ........................... : Address ............................................ :

10055611 001 See cover page N/A N/A See cover page See cover page TÜV Rheinland Taiwan Ltd. 11F., No.758, Sec. 4, Bade Rd., Songshan Dist., Taipei City 105, Taiwan. Testing location/ procedure .............. : CBTL TMP WMT SMT Testing location/ address ................. : TUV Rheinland Taiwan Ltd., Taichung Laboratory. No. 9, Ln. 36, Sec. 3, Minsheng Rd., Daya District, Taichung City 428, Taiwan. Applicant’s name .............................. : Asian Power Devices INC. Address ............................................ : 3F, No.209, Nan Yang St., Xizhi Dist., New Taipei City 221, Taiwan Test specification: Standard ........................................... : IEC 62109-1: 2010, EN 62109-1: 2010 Test procedure ................................. : TÜV Rheinland Test Mark Approval Non-standard test method………..: N/A Test Report Form No. ....................... : IEC 62109-1A Test Report Form(s) Originator ........ : VDE Testing and Certification Institute Master TRF....................................... : Dated 2011-03 Copyright © 2011 Worldwide System for Conformity Testing and Certification of Electrical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. Test item description ........................ : Grid Tie PV inverter Trade Mark ....................................... : 1) PrimeVOLT or REP, 2) or SENERGY Manufacturer .................................... : Same as applicant Model/Type reference ...................... : 1) PV-5000E-V, 2) PVT-SE5KTL Ratings ............................................. : DC rated inout: DC input voltage range: 70-600Vdc, DC input MPPT voltage range: 240-520Vdc, DC Max. input voltage: 600Vdc, DC Max. input current: 10.4Ax2, DC Max. PV Isc: 15Ax2 AC rated output: 220/230/240V, 50/60Hz, 22.7/21.7/20.8A, 5000W/5000VA, PF 0.99 max, or 230Vac, 50Hz, 21.7A, 5000W/5000VA, PF 0.99 max.