VRF Indoor unit High Static Pressure Duct (2nd Generation DC Series,50Hz) Submittal Data Job Data Buyer Buyer PO# Unit number Performance data certified by

Location Carrier# Model number Date

High Static Pressure Duct Feature  

DC motors : energy saving, low noise and more reliable External static pressure can be up to 200Pa (models 71 to 160) ,250Pa(models 200-280),400Pa(model560) A double-skin drainage pan provides double protection for ceilings (models 71 to 160) Drain pump with a 750mm pump head available as a customization option 20-step static pressure control on all models (requires latest generation wired controllers)

   Accessories (optional) Wireless remote controller: WL-12D-CM, WL-12B-CM Wired remote controller: WR-86KD-CM, WR-120G-CM Centralized controller: CRF-180A-CM, CRF-270B-CM Grille panel:/

Specifications Model

42VD024H115011016

42VD028H115011016

42VD030H115011016

Power supply

42VD036H115011016

42VD048H115011016

42VD054H115011016

1 phase,220-240V, 50Hz

Cooling1

Heating2

Fan motor

Capacity

kBtu/h

24.2

27.3

30.7

38.2

47.8

54.6

Power input

kW

0.18

0.18

0.22

0.38

0.42

0.70

Capacity

kBtu/h

27.3

30.7

34.1

42.7

54.6

58

Power input

kW

0.18

0.18

0.22

0.38

0.42

0.70

2.9

4.5

4.7

Type

DC

Quantity

1

Minimum Circuit Amps(MCA)

A

2.1

Maximum Overcurrent Protection(MOP)

A

15

Indoor air flow rate

CFM

800/781/761/742/ 722/702/683

726/699/671

896/846/795

10671005/942

1260/1183/1107

Fan speed

RPM

970/950/940/910/

980/950/930/900/

1110/1070/1010/970/

1015/975/935/905/

1080/1050/1000/960/

880/860/840

870/840/810

920/870/840

845/805/765

920/870/830

42/41/40/ 40/

45/44/43/42/

48/47/46/45/

45/44/43/ 42/

46/45/44/ 43/

39/39/38

41/40/39

43/42/41

41/40/40

42/41/40

Sound pressure level

Main body

Pipe connection

3

2.1

2.2

15

15

15

15

15

836/808/781/753/

1101/1049/999/948/

1318/1255/1193/1130/

1566/1489/1413/1336/

dB(A)

Net dimension(W×H×D)

mm

965×423×690

Ship dimension(W×H×D)

mm

1090×440×768

1322×423×691

Net weight

kg

41

51

68

68

Ship weight

kg

47

57

67

76

Liquid pipe o.d.(flare)

mm

Gas pipe o.d.(flare)

mm

Ф15.9

Drain pipe o.d.

mm

OD Φ25

1436×450×768

Ф9.53

1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m, level difference 0. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m, level difference 0. 3. Sound pressure level is measured 1.4m below the unit in a semi-anechoic chamber.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs and without incurring obligations Page 1

Specifications Model

42VD070H115011016

42VD085H115011016

42VD096H115011016

Power supply

42VD140H115011016

42VD160H115011016

42VD190H115011016

153.54

191.1 2.272

1 phase,220-240V, 50Hz

Cooling1

Heating2

Fan motor

Capacity

kBtu/h

68.2

85.3

95.5

Power input

kW

0.99

1.20

1.20

1.8

1.8

Capacity

kBtu/h

76.8

88.7

107.5

153.6

191.1

215

Power input

kW

0.99

1.20

1.20

1.80

1.80

2.272

Type

136.5

DC

Quantity

1

2

Minimum Circuit Amps(MCA)

A

6.7

Maximum Overcurrent Protection(MOP)

A

15

Indoor air flow rate

CFM

2549/2490/2431/2372/ 2313/2254/2195

3002/2796/2590

3414/3178/2943

Fan speed

RPM

1210/1180/1150/1130/

1060/1015/960/900/

1103/1043/978/927/

1100/1080/1050

840/785/735

869/820/755

Sound pressure level3

dB(A)

51/50/50/ 49/49/48/47

60/59/58/57/55/54/52

59/58/57/56/55/53/51

Main body

Net dimension(W×H×D)

mm

1454×515×931

2005×929×670

Ship dimension(W×H×D)

mm

1509×550×990

2095×964×800

Net weight

kg

130

210

Ship weight

kg

142

235

248

Liquid pipe o.d.(flare)

mm

Ф12.7

Ф15.9

Ф15.9

Gas pipe o.d.(flare)

mm

Ф22.2

Ф28.6

Ф28.6

Drain pipe o.d.

mm

OD Ф32

OD Ф32

OD Ф32

Pipe connection

6.7

6.7

12.5

12.5

15

15

30

30 3826/3620/3414/3208/

15.4 30 4356/4120/3885/3649/

218

1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m, level difference 0. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m, level difference 0. 3. Sound pressure level is measured 1.4m below the unit in a semi-anechoic chamber.

Dimensional Drawing (mm)

40-56kW

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs and without incurring obligations Page 2

Related Documents

Static Equipment
March 2021 0
Delphi Pressure
January 2021 1
Itp For Duct Work
March 2021 0
Blood Pressure
January 2021 1
Hydro Static Drive
February 2021 1

More Documents from "beau042"