Loading documents preview...
AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 1 of 7

AutoPIPE Vs Caesar - User interface

Applies To Product(s):

AutoPIPE

Version(s):

V8i

Environment:

N/A

Area:

New Users

Subarea: Original Author:

Bentley Technical Support Group

Problem:

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__...

2016-09-09

AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 2 of 7

AutoPIPE and Caesar are both 2 iconic programs that perform the same functions; Pipe Stress Analysis based on pipe arrangement, pipe properties, and applied loads. Although these applications have the same end goal, provide stress analysis results, they are different programs with different methodology. This WIKI is to help new users of AutoPIPE that had used Caesar before, but have now migrated to AutoPIPE.   

Answer: Item #1:  1 of 2, most important differences between AutoPIPE & Caesar Non-linear Load Sequencing Explained

Item #2:  2 of 2, most important differences between AutoPIPE & Caesar AutoPIPE vs Caesar load combinations

Item #3: C-Node or Connecting Nodes in Caesar

Item #4: Compare AutoPIPE Input Grids with Caesar Spreadsheets

item #5: Dynamic Load questions :

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__...

2016-09-09

AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 3 of 7

1. Dynamic load factor 2. The default % value of critical damping used in Caesar II Are answered on the following WIKI page: Dynamic Analysis in AutoPIPE

Item #6: Modeling Support - AutoPIPE 1. Item #8: Modeling Guide Supports 2. Item #11: Define a Displacement at a Support Are answered on the following WIKI page: Modeling Support - AutoPIPE

Item #7: Error message: The load case did not converge. Do you wish to continue iterating?

Item #8: Graphical Point Editing Caesar users are used to looking at the model, then reading and entering the point name. In AutoPIPE like CAD use point and click, point names are automatically taken care of. Productivity Example - Add a Support

AutoPIPE

1. Click on the Support Point 2. Select Support Type (Friction & Gaps)



Caesar

1. Look at the Graphic Plot & Read Point Name 2. Go to the data sheet

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__...



2016-09-09

AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 4 of 7

3. Click on the Restraint Option 4. Enter the Point Name 5. Select Support Type (Friction & Gaps)

• 2 way gaps permitted all supports • Guide - Both Horiz. + Vertical

• Only 1 gap permitted • 2 supports required for Guide + Y





Item #9: Pipe Stress Work involves lots of Iterations 99 levels of Undo / Redo are available at all times in AutoPIPE such that different support configurations can be tried and if stresses or equipment loads are worse then can easily revert back to some previous state. But in Caesar undo/redo is always lost when exit the INPUT module. Alphanumeric node numbering by segments – easy to identify which nodes relate to which parts / line numbers of the model

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__...

2016-09-09

AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 5 of 7

Item #10: Defining Wind, Wave, and Earthquake Loads Go to the Load menu to define them Note: Up to 10 (AutoPIPE V8i 09.06.00.xx and lower) or 30 (AutoPIPE V8i 09.06.01.xx and higher) seismic loads are available useful for evaluating +X, -X, +Z, -Z as a minimum for non-linear cases. (Only 3 uniform loads available in Caesar). Similarly up to 10 wind cases available in the one static analysis.

Item #11: Define a displacement at a support In AutoPIPE simply assign a displacement at the support for any load case, GR, T1, T2, E1, etc during modelling. Caesar has limitation of defining only 9 displacements which have to be combined in post processing to specific load cases. Insert > Xtra data > imposed support displacement. These can be applied also to anchors but only act in the direction of the restraint.

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__...

2016-09-09

AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 6 of 7

item #12: Download file: Caesar_autopipe_Translation_5.pdf File contains information on the following topics: • • • • • • • •

AutoPIPE / Caesar Translation Caesar Neutral File Versions Transferring Caesar Model to AutoPIPE Transfer Large Caesar Models AutoPIPE Configurable Mapping Translation Limitations Comparative Results Write AutoPIPE Model to Caesar

See Also Bentley AutoPIPE

External Links Bentley Technical Support KnowledgeBase

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__...

2016-09-09

AutoPIPE Vs Caesar - User interface - AutoPIPE Wiki - AutoPIPE - Bentley Communities

Page 7 of 7

Bentley LEARN Server

Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!

The load case did not converge. Do you wish to continue iterating?  New user

 Caesar

 AutoPIPE

Created by Mike Dattilio When: Tue, Jun 3 2014 8:05 PM Last revision by Mike Dattilio When: Wed, Aug 13 2014 12:23 AM Revisions: 3 Comments: 0