Loading documents preview...
DESIGN OF SQUARE FOOTING Design Constants: fc’ = 21 MPa fc = 9.45 MPa fs = 124 MPa n = 10 γconrete = 23.6 kN/m3 Covering = 40 mm k = 0.432 j = 0.856 R = 1.75 va 0.09 f c ' 0.412 MPa v p 0.17 f c ' 0.779 MPa
LL = 1.9 kN/m2 Allowable Soil Pressure = 143 kPa Total Service Load, Ptotal: From design of axially loaded column P5 = 358.33 kN load @ 5th floor P = 5P5 + Weight of column 5 + Weight of column 4 + Weight of column 3 + Weight of column 2 + Weight of column 1 P = 358.33(5) + 0.2542 (4)(23.6) + 0.3352(4)(23.6) + 0.412 (4)(23.6) + 0.4752 (4)(23.6) + 0.532 (4)(23.6) P = 1872 kN Ptotal = P + 6% of P Ptotal = 1872 + ( 0.07 ) 1872 Ptotal =2003.04 kN Wt. of footing = 0.07(1872) = 131.04 kN Required Area: P S total A A
2003 143
A = 14 m2 L2 = 14 L = 3.7 m
Try 3.7 m x 3.7 m Footing Effective Depth: 2003 3.7 2 Net Upward Soil Pressure = 146.31 kN/m2 Net UpwardSoil Pressure
( From Bending ) d
M Rb
1.585 M 146.31(3.7)(1.585) 2
M = 680.13 kN-m d
673.441x10 6 1.75(3700)
d = 324.09mm Says d = 350 mm Try d = 250 + 200
d =550 mm ( Check Shear ) V bd V = 144.9 ( 1.035 ) ( 3.7 ) V = 560.29 kN v
v
560.29 (10 3 ) 3.7(0.55)
v = 0.275 MPa < 0.412 MPa (safe)
( Check Punching Shear ) vp
Vp
Ap Vp = 146.31 [(3.7)2 - (1.08)2] Vp = 1832.33 kN vp
183.2.33 1.08(0.55)(4)
(10 3 )
vp = 0.771 MPa < 0.779 MPa (safe) Use d = 550 mm Steel Reinforcement: (Using 28 mm Ф bars) M As f s jd As
680.13x10 6 124(0.856)(550)
As = 11650.21 mm2 (d ) 2 N As 4 2 4
(28) N 11650.12
N = 18.92 Says N = 19-28 mm Ф bars bothways Use 19-28 mm Ф bars bothways Check Bond Stress: V u o jd V = 146.31 ( 1.585 ) ( 3.7 ) V = 858 kN u
858(1000) (28)19(0.856)(550)
u = 1.09 MPa < 1.859 MPa (safe) Check for Weight: Total depth = 550 + 75 + 14 Total depth = 639 mm Wt. of footing = 0.639 (3.7)2 (23.6) Wt. of footing = 206 kN > 112.32 kN (safe)