afety devices
The Series Z escalator is equipped with various safety devices that provide for safety and reliability.
For
EN115 Code ●…Standard
○ Step Motion Safety Device (CRS) A safety device to stop the escalator when a Step has been dislocated on its riser side due to an object caught between the Steps, or between the Skirt Guard and the Step, or if an abnormality has been observed in the Step motion.
● Emergency Stop Button (E-STOP) A button to immediately stop the escalator in emergency situations.
●* Door Open Switch (DOS)
* - EN115-1: 2008 + A1: 2010 → Standard - EN115-1/A2: 2004 → Not applicable
● Overload Detection Device A safety device that stops the escalator if overload has been detected by abnormal current or temperature of the drive motor.
● Drive Chain Safety Device (DCS) A safety device that stops the escalator if the Drive Chain breaks or stretches beyond an allowable limit.
● Speed Governor (GOV) A safety device that stops the escalator if the speed significantly decreases or increases to 120% of the rated speed.
A safety device that stops the escalator if the speed exceeds the rated speed, or before the Steps’ traveling direction changes due to an abnormality such as breakage of the Drive Chain.
● Electromagnetic Brake A safety device that stops the escalator in the case of power failure, or if any safety device or the Emergency Stop Button has been activated.
* A standard device for public-use escalators or those exceeding 6m in rise.
● Step Level Device (SRS) A safety device that stops the escalator if the horizontal level of a Step has dropped.
○ Skirt Guard Safety Device (SSS) A safety device to stop the escalator if a shoe or other item becomes trapped in the gap between the Step and Skirt Guard.
●* Handrail Speed Safety Device (HSS) A safety device that stops the escalator if the Moving Handrails fail to synchronize with the Steps due to slippage, loosening or breakage of the Moving Handrails. * - EN115-1: 2008 + A1: 2010 → Standard - EN115-1/A2: 2004 → Optional
● Comb-Step Safety Switch (CSS) A safety device that stops the escalator if a foreign object becomes trapped in the gap between the Step and Comb.
L - 1 7 0 - 6 - C 7 9 4 0 0 -E
Division Environment
Specification Indoor Semi-outdoor
ZS
ZL
*1
N/A
● *1
ZP
*1 ● ○ *2 Control ○ Automatic Operation with Posts (Stationary in stand-by, AC1) system ○ Automatic Operation with Posts (Slow operation in stand-by, Inverter) ○ Post-Free Automatic Operation (Slow operation in stand-by, Inverter) ● Stop-Buzzer Key Switch Anti-Slip Floor Plate ● ● Step with Anti-Slip Grooves ● Demarcation Line Tiered Demarcation Line ● Safety ○ Step Demarcation Lighting ○ Comb Light features ○/● *3 Three Horizontal Steps ○ *4 Warning System on Moving Handrail Inlet (Inlet Sensor) ○ *4 Warning System on Outer Deck (Outer Deck Sensor) N/A ○*4 *5 Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator) N/A Transparent tempered glass panel ● Balustrade N/A Under-Handrail Lighting ● N/A See page 12 for sections. Stainless steel hairline panel ● N/A Fluoropolymer Coating ● Skirt Guard Skirt Guard Lighting ○*6 N/A ○*6 Deck Board Stainless steel hairline ● Aluminum alloy Step Tread ● Step Finish and Aluminum alloy Cleat Riser ● Yellow Demarcation Line ● decorative Decorative Panel (Embossed stainless steel) ● components Floor Plate Floor Name ○ Comb ● Extension of Floor Plate ○ Connection of adjacent Floor Plates ○ Moving Handrail Rubber No. 0001 (Black) ● (See page 5 for colors.) ○ No. 0502 to 0508 Handrail Inlet Cap Resin ● MelEye ○ Others Automatic oiler ○ Outdoor
AC1 Inverter (VVVF)
*1: Please contact your local Mitsubishi Electric sales agent for semi-outdoor and outdoor use. *2: Please contact your local Mitsubishi Electric sales agent for VVVF control. *3: A standard feature for rises exceeding 6000mm or rated speeds exceeding 0.5m/sec. *4: Not applicable to outdoor use. *5: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas). *6: Not applicable to semi-outdoor and outdoor use.
Deck Board
Step
Skirt Guard
Floor Plate
●* Missing Step Device (SMS) A safety device that stops the escalator if it detects a missing step(s) before it is visible to passengers. * - EN115-1: 2008 + A1: 2010 → Standard - EN115-1/A2: 2004 → Not applicable
e4
●…Standard ○…Optional N/A…Not applicable
Balustrade
1) Inlet Guard A guard made of soft rubber, which fits over the outside of the Moving Handrail where it enters the Balustrade to keep fingers, hands or foreign objects away from the Moving Handrail opening. 2) Inlet Guard Switch A safety device that stops escalator when physical contact is made with the inlet.
A safety device that stops the escalator if the Step Chain breaks or stretches beyond an allowable limit.
EN115 Code
Max rise (mm): 7000 (30°), 6000 (35°)
Moving Handrail
● Handrail Guard Safety Device (HGS)
● Step Chain Safety Device (SCS)
For
○…Optional
A safety switch that stops the escalator when the manhole cover is opened.
○* Auxiliary brake
S
pecifications
Operating Panel Escalators in the graphics are based on the Japan Code, with optional Fluoropolymer Coating on Skirt Guard.
e1
EN 30°
EN 35°
NJ-865 RC, SRC structure Min. 270 Steel structure Min. 250 Finished floor level
50
Support beam end
Distance between support beams MM
+30 0
+40 0
Truss end
TK
Support beam section detail (by owner)
50
LA Max. 11000 for S1000, S800 Max. 11700 for S600
W2
Clearance Min.2000
950
F.L.
RB F.L.
R2100
Wedge guard (by owner)
W.P.
440
440
TJ-140
NK R1500
Floor opening Min. 2000
Height of intermediate support beams,180~1000.
1245
Outer sheathing panel (by owner)
RC SA
35°
950
W.P. 1100
1100
1030
NK-385
F.L.
Intermediate support beam is required when TG exceeds 15000mm for Type S1000 15500mm for Type S800 or 16000mm for Type S600
1030
SA
RA
W.P.
Floor opening Min. 1800
For VVVF control, TJ may increase from that shown. Please contact your local Mitsubishi Electric sales agent for details.
■Standard dimensions S600
S800
S1000
W1 (Escalator Width)
1150
1350
1550
W2 (Between Moving Handrails)
840
1040
1240
W3 (Between Skirt Panels)
610
810
1010
LF
UF
NK
NJ
2 Steps
850
1100
1550
1835
3 Steps
1440
1725
1975
2260
Without intermediate support beam
S800
S600
e2
TG
TG 13500<TG 15000<TG TG 13850<TG 15500<TG TG 14200<TG 16000<TG
■Reaction force on beam (N)
α・LL+ 4220・(LL-TK+X1)+12000・(TJ-X2) LL
α・LA+4220-
RB
α・LL+ 4220・(TK-X1)+12000・(LL-TJ+X2) LL
α・LB+12000- 12000・(TJ-X2) LB 12000・(TJ-X2) α・LL+ 4220・(TK-X1) + LA LB
RC
Type
S600
S800
S1000
W1 (Escalator Width)
1150
1350
1550
W2 (Between Moving Handrails)
840
1040
1240
W3 (Between Skirt Panels)
610
810
1010
Horizontal Steps
LF
UF
NK
NJ
2 Steps
1095
1365
1630
1900
Without intermediate support beam RA
α・LL+ 4220・(LL-TK+1111)+12000・(TJ-1370) LL
With intermediate support beam α・LA+4220-
4220・(TK-1111) LA
RB α・LL+ 4220・(TK-1111)+12000・(LL-TJ+1370) LL
α・LB+12000- 12000・(TJ-1370) LB
RC
α・LL+ 4220・(TK-1111) + 12000・(TJ-1370) LA LB
■Reaction force factors α(N/mm)
S1000
4220・(TK-X1) LA
RA
■Reaction force factors
Type
With intermediate support beam
Height of intermediate support beams,180~1000.
Intermediate support beam is required when TG exceeds 15000mm for Type S1000 15500mm for Type S800 or 16000mm for Type S600
For VVVF control, TJ may increase from that shown. Please contact your local Mitsubishi Electric sales agent for details.
■Standard dimensions
■Reaction force on beam (N)
Type
Wiring inlet (R.H.)
Truss
RC
30°
950
RA
2390 (S1000,S800) 2940 (S600) 50
Outer sheathing panel (by owner) F.L.
RB F.L.
Ceiling
Clearance Min. 2000
HE Rise Max. 6000
Overhead Min. 2320
Recommended
Recommended
5
Truss
5
R1500
Wiring inlet (R.H.)
125
1515
215
91
NK
Clearance Min.2000
F.L.
1030
NJ-385 20
91
HE Rise Max. 7000
LB Max. 11000 for S1000, S800 Max. 11700 for S600 NJ
Safety fence (by owner)
0
Clearance Min. 2000
LA Max. 11000 for S1000, S800 Max. 11700 for S600
+30 0
TJ=2530 (S1000, S800) TJ=3080 (S600)
HE/tan35°
79
Ceiling
TK=2260
50
0
Recommended
79
440
75
Truss length TG
W1
W.P.
Wedge guard (by owner)
+40 0
W3 250
R2100
440
50
+30 0
W2
W3
Recommended
Support beam end Truss end
NJ
Safety fence (by owner)
Wiring inlet (R.H.)
Max.UF
Upper floor opening
Distance between support beams MM
75
Support beam section detail (by owner)
LB Max.11000 for S1000, S800 Max.11700 for S600
W1
Lower floor opening
LL=TG+250 Anchor
+30 0
TJ
HE/tan30°
1035
765
Max. LF
75
Truss length TG
Comb
250
75
Wiring inlet (R.H.)
Max. UF
Upper floor opening
LL=TG+250
Comb
950
Lower floor opening
Max. LF
Anchor
Floor opening W1+100
Floor opening W1+100
NK-865
Manhole cover
Manhole cover
Comb
Comb
120±10
RC, SRC structure Min. 270 Steel structure Min. 250 Finished floor level
(Unit: mm)
Manhole cover
1030
Manhole cover
Overhead Min. 2340
(Unit: mm)
Horizontal Steps
EN115 Code
For
120±10
L
ayout
13500 15000 13850 15500 14200 16000
2 Steps
Environment
Type
Indoor Outdoor Semi-outdoor 5.25 5.25 5.32 5.25 4.56 4.62 4.56 3.87 3.87 3.93 3.87
S1000 S800 S600
TJ HE 6000
2465
α(N/mm) X1
TK
2180
X2
Type
1031 1305
3015
S1000
3 Steps Type S1000 S800 S600
TJ HE 6000 6000<HE
2890
TK
X1
X2
S800
3440 3440 3440
2605
1456 1730
S600
Environment
TG
TG 13500<TG 15000<TG TG 13600<TG 15250<TG TG 14200<TG 16000<TG
13500 15000 13600 15250 14200 16000
Indoor Outdoor Semi-outdoor 5.25 5.25 5.32 5.25 4.56 4.62 4.56 3.87 3.87 3.93 3.87
e3