14000 6000

2700

FLOOR PLAN

5300

SCALE

1:130

W3

WALK-IN CLOSET

6000

3000

T&B

W3

W1

MASTER'S BEDROOM

W1

T&B D3

KITCHEN

W1

3000

D5

D4

8000

W1

DINING AREA

BEDROOM 1

D6

5000

4000

14000

LIVING AREA

D2

D2

4000

BEDROOM 2

W1

W1

1000

1800

W1 D1

W1

CARPORT

W2

PORCH

4000

2000

3000

4000

13000

SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR

SHEET NO:

SHEET CONTENTS:

ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN

FLOOR PLAN

A1 1/6

r

r

C5

r

LIGHTING LAYOUT

r

SCALE

C4

b

1:180

b

So

n

o

Sn b

m

m

b

b

r

k

r

l f

p Sp

S klm

m j

j d i

h

b

e

b

d

Sgh

C1 Scd ab c S

g

r

C2

S ij

j

r

h

h

b a

b

b

C3 Sqrs

s

s s s OUTDOOR FOUNTAIN

q

s

r

r

SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR

r

r

r

r

ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN

SHEET CONTENTS: LIGHTING LAYOUT

SHEET NO: E1 2/6

POWER & AUX. LAYOUT SCALE

1:180

C11 WH

ACU C10

WH

REF C12

C13 RANGE PB

WP C14

ACU C7

C9

CATV

TEL WP ACU C8

CARPORT PORCH

DB C6

SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR

ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN

SHEET CONTENTS: POWER & AUX. LAYOUT

SHEET NO: E2 3/6

SINGLE LINE DIAGRAM SCALE

1:20

METERING CONDUIT

KWHR METER

1

15AT

15AT

2

3

15AT

15AT

4

5

15AT

20AT

6

7

20AT

20AT

8

9

20AT

20AT

10

11

20AT

20AT

12

13

20AT

20AT

14

1400

2000

80AT/80AF, 2P 230V AC

GROUND BUS BAR

FINISH FLOOR LINE

GROUNDING SYSTEM SOFT DRAWN BARE COPPER WIRE. 14 mm BARE COPPER WIRE IN 25 mm Ø X 240 mm LENGTH GROUNDING ROD COPPERWELD

NATURAL GROUND LINE

SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR

ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN

SHEET CONTENTS: SINGLE LINE DIAGRAM

SHEET NO: E3 4/6

ELECTRICAL NOTES: LEGEND:

Sab

ACU

INCANDESCENT CEILING LAMP, SURFACE MOUNTED ON PORCELAIN KEYLESS RECEPTACLE, 240 V, 100 WATTS

CONDUCTOR IN CONDUIT EXPOSED OR CONCEALED ABOVE SUSPENDED CEILINGS AND/OR WALL PARTITIONS.

WALL SWITCH, TOGGLE TYPE, SINGLE POLE, 10A, 240V, SUBSCRIPT LETTER DENOTES LIGHT CONTROLLED (S3WC - FOR THREE WAY SWITCH)

CONDUCTOR IN CONDUIT EMBEDDED IN CONCRETE OR BURRIED UNDERGROUND.

WALL AIR CONDITIONING OUTLET, SINGLE, 20 Amps., 3-WIRE, 250V, GRINDING. TYPE FLUSH MOUNTED WITH MATCHING DEVICE PLATE

20AT/50AF CIRCUIT BREAKER, THERMAL MAGNETIC, AMPERE RATING AS SHOWN IN THE DRAWING.

WALL DUPLEX CONVENIENCE OUTLET, 15 Amps., 3-WIRE, 240V GRINDING. TYPE W/ MATCHING DEVICE PLATE. (WP-FOR WEATHER PROOF OUTLET; RANGE- FOR RANGE OUTLET; REF- FOR REFRIGERATOR OUTLET) TELEPHONE WALL OOUTLET, FLUSH MOUNTED W/ MATCHING DEVICE PLATE COVER.

CATV

C3

CABLE T.V. WALL OOUTLET, FLUSH MOUNTED W/ MATCHING DEVICE PLATE COVER.

PANEL BOARD, RATING AND CAPACITY AS SHOWN IN THE DRAWINGCONFRORMANCE W/ R.A. 7920.

SERVICE ENTRANCE, 2300V, 60Hz, 3-WIRE, SINGLE PHASE.

WALL DOOR BELL OUTLET

1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE PLANS & SPECS, AND THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, IT'S RULES AND REGULATIONS, OF THE LOCAL ENFORCING AUTHORITY & THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORK SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED PROFESSIONAL ELECTRICAL ENGINEER. 2. ALL WIRES SHALL BE COPPER & THERMOPLASTIC INSULATED TYPE "THHN" UNLESS OTHERWISE INDICATED. USE PHELPS DODGE OR COLUMBIA BRAND. 3. THE CONTRACTOR SHALL VERIFY & ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY. 4. ALL FEEDERS & BRAND CIRCUIT HOMERUN SHALL BE INSTALLED AS INDICATED ON THE PLANS. BRAND CIRCUIT HOMERUN WIRES SHALL BE INSTALLED IN INDIVIDUAL HOMERUN CONDUITS. 5. ANY DISCREPANCY IN LOCATION & RANGE OF EQUIPMENT AND/OR APPARATUS TO BE INSTALLED SHALL BE VERIFIED WITH THE OWNER OR HIS AUTHORIZED REPRESENTATIVE, & CHANGES SHALL BE MADE ACCORDINGLY. 6. ALL MATERIALS & EQUIPMENT TO BE USED & INSTALLED SHALL BE BRAND NEW, OF THE APPROVED TYPE FOR THE LOCATION AND PURPOSE INTENDED. 7. ALL POWER & CONVENIENCE OUTLETS SHALL BE GROUNDING TYPE. 8. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS: a. LIGHT SWITCHES - 1.40 M. ABOVE FINISH FLOOR LINE b. CONVENIENCE OUTLETS - 0.30 M. ABOVE FINISH FLOOR LINE c. TELEPHONE OUTLETS - 0.30 M. ABOVE FINISH FLOOR LINE d. PANELBOARD & CABINETS - 1.40 M. ABOVE FINISH FLOOR LINE e. CABLE TV OUTLET - 0.30 M. ABOVE FINISH FLOOR LINE

CIRCUIT HOMERUN, NUMBER OF HATCH MARKS INDICATE NUMBER OF CONDUTORS OTHER THAN TWO (ALL THRU OUT). SUBSCRIPT INDICATE CIRCUIT NUMBER.

SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR

ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN

SHEET CONTENTS: SYMBOLS & LEGENDS ELECTRICAL NOTES

SHEET NO: E4 5/6

PANELBOARD: CKT. NO.

PB-1

DESCRIPTION

MAIN: 80AT / 80 AF, 2P 230V AC QTY

LOAD IN WATTS

TOTAL WATTS

VOLT

AMP

AT

AF

CIRCUIT BREAKER WIRE & CONDUIT SIZE

1

LIGHTING OUTLET

11

100

1100

230

4.78

15

80

2.00 mm² THW IN 15mmØ C

2

LIGHTING OUTLET

11

100

1100

230

4.78

15

80

2.00 mm² THW IN 15mmØ C

3

LIGHTING OUTLET

10

100

1000

230

4.35

15

80

2.00 mm² THW IN 15mmØ C

4

LIGHTING OUTLET

10

100

1000

230

4.35

15

80

2.00 mm² THW IN 15mmØ C

5

LIGHTING OUTLET

10

100

1000

230

4.35

15

80

2.00 mm² THW IN 15mmØ C

6

CONVENIENCE OUTLET

7

180

1260

230

5.48

20

80

3.50 mm² THW IN 15mmØ C

7

CONVENIENCE OUTLET

6

180

1080

230

4.70

20

80

3.50 mm² THW IN 15mmØ C

8

ACU

1

1440

1440

230

6.26

20

80

3.50 mm² THW IN 15mmØ C

6.26

20

80

3.50 mm² THW IN 15mmØ C

9

ACU

1

1440

1440

230

10

ACU

1

1440

1440

230

6.26

20

80

3.50 mm² THW IN 15mmØ C

11

WATER HEATER

1

360

360

230

1.57

20

80

3.50 mm² THW IN 15mmØ C

12

WATER HEATER

1

360

360

230

1.57

20

80

3.50 mm² THW IN 15mmØ C

13

REFRIGERATOR

1

500

500

230

2.17

20

80

3.50 mm² THW IN 15mmØ C

14

RANGE

1

3000

3000

230

13.04

30

80

5.50 mm² THW IN 15mmØ C

TOTAL

16080

69.92 USE: 2-14mm² THHN 1.35mm² THHN GROUNDING 25mm Ø RSC

DESIGN COMPUTATION: FEEDER CONDUCTORS I fc = 69.92 + (0.25 x 6.26) = 71.49 A

OVER CURRENT PROTECTION Iop= 69.92 + (1.25 x 6.26) = 77.75 A

80AT / 80 AF, 2P 230V AC

SCHEDULE OF LOADS & COMPUTATIONS SCALE

SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR

NTS

ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN

SHEET CONTENTS: SCHEDULE OF LOADS & COMPUTATIONS

SHEET NO: E5 6/6

Related Documents

Eplan
February 2021 3
Eplan
February 2021 4
Iec_sybols (eplan)
February 2021 1
Eplan Curs
February 2021 2
Eplan Manual
January 2021 1
Eplan Electric P8 Basici
February 2021 1

More Documents from "hungvtc9"

Eplan
February 2021 4
February 2021 0
January 2021 0
Dsm 5 Completo
February 2021 1
January 2021 0