Loading documents preview...
14000 6000
2700
FLOOR PLAN
5300
SCALE
1:130
W3
WALK-IN CLOSET
6000
3000
T&B
W3
W1
MASTER'S BEDROOM
W1
T&B D3
KITCHEN
W1
3000
D5
D4
8000
W1
DINING AREA
BEDROOM 1
D6
5000
4000
14000
LIVING AREA
D2
D2
4000
BEDROOM 2
W1
W1
1000
1800
W1 D1
W1
CARPORT
W2
PORCH
4000
2000
3000
4000
13000
SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR
SHEET NO:
SHEET CONTENTS:
ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN
FLOOR PLAN
A1 1/6
r
r
C5
r
LIGHTING LAYOUT
r
SCALE
C4
b
1:180
b
So
n
o
Sn b
m
m
b
b
r
k
r
l f
p Sp
S klm
m j
j d i
h
b
e
b
d
Sgh
C1 Scd ab c S
g
r
C2
S ij
j
r
h
h
b a
b
b
C3 Sqrs
s
s s s OUTDOOR FOUNTAIN
q
s
r
r
SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR
r
r
r
r
ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN
SHEET CONTENTS: LIGHTING LAYOUT
SHEET NO: E1 2/6
POWER & AUX. LAYOUT SCALE
1:180
C11 WH
ACU C10
WH
REF C12
C13 RANGE PB
WP C14
ACU C7
C9
CATV
TEL WP ACU C8
CARPORT PORCH
DB C6
SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR
ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN
SHEET CONTENTS: POWER & AUX. LAYOUT
SHEET NO: E2 3/6
SINGLE LINE DIAGRAM SCALE
1:20
METERING CONDUIT
KWHR METER
1
15AT
15AT
2
3
15AT
15AT
4
5
15AT
20AT
6
7
20AT
20AT
8
9
20AT
20AT
10
11
20AT
20AT
12
13
20AT
20AT
14
1400
2000
80AT/80AF, 2P 230V AC
GROUND BUS BAR
FINISH FLOOR LINE
GROUNDING SYSTEM SOFT DRAWN BARE COPPER WIRE. 14 mm BARE COPPER WIRE IN 25 mm Ø X 240 mm LENGTH GROUNDING ROD COPPERWELD
NATURAL GROUND LINE
SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR
ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN
SHEET CONTENTS: SINGLE LINE DIAGRAM
SHEET NO: E3 4/6
ELECTRICAL NOTES: LEGEND:
Sab
ACU
INCANDESCENT CEILING LAMP, SURFACE MOUNTED ON PORCELAIN KEYLESS RECEPTACLE, 240 V, 100 WATTS
CONDUCTOR IN CONDUIT EXPOSED OR CONCEALED ABOVE SUSPENDED CEILINGS AND/OR WALL PARTITIONS.
WALL SWITCH, TOGGLE TYPE, SINGLE POLE, 10A, 240V, SUBSCRIPT LETTER DENOTES LIGHT CONTROLLED (S3WC - FOR THREE WAY SWITCH)
CONDUCTOR IN CONDUIT EMBEDDED IN CONCRETE OR BURRIED UNDERGROUND.
WALL AIR CONDITIONING OUTLET, SINGLE, 20 Amps., 3-WIRE, 250V, GRINDING. TYPE FLUSH MOUNTED WITH MATCHING DEVICE PLATE
20AT/50AF CIRCUIT BREAKER, THERMAL MAGNETIC, AMPERE RATING AS SHOWN IN THE DRAWING.
WALL DUPLEX CONVENIENCE OUTLET, 15 Amps., 3-WIRE, 240V GRINDING. TYPE W/ MATCHING DEVICE PLATE. (WP-FOR WEATHER PROOF OUTLET; RANGE- FOR RANGE OUTLET; REF- FOR REFRIGERATOR OUTLET) TELEPHONE WALL OOUTLET, FLUSH MOUNTED W/ MATCHING DEVICE PLATE COVER.
CATV
C3
CABLE T.V. WALL OOUTLET, FLUSH MOUNTED W/ MATCHING DEVICE PLATE COVER.
PANEL BOARD, RATING AND CAPACITY AS SHOWN IN THE DRAWINGCONFRORMANCE W/ R.A. 7920.
SERVICE ENTRANCE, 2300V, 60Hz, 3-WIRE, SINGLE PHASE.
WALL DOOR BELL OUTLET
1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE PLANS & SPECS, AND THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, IT'S RULES AND REGULATIONS, OF THE LOCAL ENFORCING AUTHORITY & THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORK SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED PROFESSIONAL ELECTRICAL ENGINEER. 2. ALL WIRES SHALL BE COPPER & THERMOPLASTIC INSULATED TYPE "THHN" UNLESS OTHERWISE INDICATED. USE PHELPS DODGE OR COLUMBIA BRAND. 3. THE CONTRACTOR SHALL VERIFY & ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY. 4. ALL FEEDERS & BRAND CIRCUIT HOMERUN SHALL BE INSTALLED AS INDICATED ON THE PLANS. BRAND CIRCUIT HOMERUN WIRES SHALL BE INSTALLED IN INDIVIDUAL HOMERUN CONDUITS. 5. ANY DISCREPANCY IN LOCATION & RANGE OF EQUIPMENT AND/OR APPARATUS TO BE INSTALLED SHALL BE VERIFIED WITH THE OWNER OR HIS AUTHORIZED REPRESENTATIVE, & CHANGES SHALL BE MADE ACCORDINGLY. 6. ALL MATERIALS & EQUIPMENT TO BE USED & INSTALLED SHALL BE BRAND NEW, OF THE APPROVED TYPE FOR THE LOCATION AND PURPOSE INTENDED. 7. ALL POWER & CONVENIENCE OUTLETS SHALL BE GROUNDING TYPE. 8. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS: a. LIGHT SWITCHES - 1.40 M. ABOVE FINISH FLOOR LINE b. CONVENIENCE OUTLETS - 0.30 M. ABOVE FINISH FLOOR LINE c. TELEPHONE OUTLETS - 0.30 M. ABOVE FINISH FLOOR LINE d. PANELBOARD & CABINETS - 1.40 M. ABOVE FINISH FLOOR LINE e. CABLE TV OUTLET - 0.30 M. ABOVE FINISH FLOOR LINE
CIRCUIT HOMERUN, NUMBER OF HATCH MARKS INDICATE NUMBER OF CONDUTORS OTHER THAN TWO (ALL THRU OUT). SUBSCRIPT INDICATE CIRCUIT NUMBER.
SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR
ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN
SHEET CONTENTS: SYMBOLS & LEGENDS ELECTRICAL NOTES
SHEET NO: E4 5/6
PANELBOARD: CKT. NO.
PB-1
DESCRIPTION
MAIN: 80AT / 80 AF, 2P 230V AC QTY
LOAD IN WATTS
TOTAL WATTS
VOLT
AMP
AT
AF
CIRCUIT BREAKER WIRE & CONDUIT SIZE
1
LIGHTING OUTLET
11
100
1100
230
4.78
15
80
2.00 mm² THW IN 15mmØ C
2
LIGHTING OUTLET
11
100
1100
230
4.78
15
80
2.00 mm² THW IN 15mmØ C
3
LIGHTING OUTLET
10
100
1000
230
4.35
15
80
2.00 mm² THW IN 15mmØ C
4
LIGHTING OUTLET
10
100
1000
230
4.35
15
80
2.00 mm² THW IN 15mmØ C
5
LIGHTING OUTLET
10
100
1000
230
4.35
15
80
2.00 mm² THW IN 15mmØ C
6
CONVENIENCE OUTLET
7
180
1260
230
5.48
20
80
3.50 mm² THW IN 15mmØ C
7
CONVENIENCE OUTLET
6
180
1080
230
4.70
20
80
3.50 mm² THW IN 15mmØ C
8
ACU
1
1440
1440
230
6.26
20
80
3.50 mm² THW IN 15mmØ C
6.26
20
80
3.50 mm² THW IN 15mmØ C
9
ACU
1
1440
1440
230
10
ACU
1
1440
1440
230
6.26
20
80
3.50 mm² THW IN 15mmØ C
11
WATER HEATER
1
360
360
230
1.57
20
80
3.50 mm² THW IN 15mmØ C
12
WATER HEATER
1
360
360
230
1.57
20
80
3.50 mm² THW IN 15mmØ C
13
REFRIGERATOR
1
500
500
230
2.17
20
80
3.50 mm² THW IN 15mmØ C
14
RANGE
1
3000
3000
230
13.04
30
80
5.50 mm² THW IN 15mmØ C
TOTAL
16080
69.92 USE: 2-14mm² THHN 1.35mm² THHN GROUNDING 25mm Ø RSC
DESIGN COMPUTATION: FEEDER CONDUCTORS I fc = 69.92 + (0.25 x 6.26) = 71.49 A
OVER CURRENT PROTECTION Iop= 69.92 + (1.25 x 6.26) = 77.75 A
80AT / 80 AF, 2P 230V AC
SCHEDULE OF LOADS & COMPUTATIONS SCALE
SUBMITTED BY: JERICO M. SUMAWANG BSCE 5-3 SUBMITTED TO: ENGR. POLICARPIO V. BULANAN INSTRUCTOR
NTS
ENGR 310 ELECTRICAL CIRCUITS AND WIRING DESIGN
SHEET CONTENTS: SCHEDULE OF LOADS & COMPUTATIONS
SHEET NO: E5 6/6