Loading documents preview...
Schindler Escalator and Moving Walk Troubleshooting Guide Q 43831001_00 Edition 10-2014
Prepared
naidura
28.08.2014
Lead Office
Classification
Document Owner
Reviewed
laeuffpe
04.09.2014
SC7
11XXX
Norms checked
plattle
03.10.2014
INVENTIO AG, CH-6052 Hergiswil
Released
ludwigj2
11.10.2014
Modification:
00
KA No.:
107490
KA Date:
11.10.2014
Copyright © 2014 INVENTIO AG All rights reserved. INVENTIO AG, Seestrasse 55, CH-6052 Hergiswil, owns and retains all copyrights and other intellectual property rights in this manual. It shall only be used by SCHINDLER personnel or authorized SCHINDLER agents for purposes which are in the interest of SCHINDLER. Any reproduction, translation, copying or storing in data processing units in any form or by any means without prior permission of INVENTIO AG is regarded as infringement and will be prosecuted.
Table of Contents Table of Contents
1
2
3 4
5
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 Protective Clothing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Personal Protective Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.6 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Identification of Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 SW, SW 77, SWE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 SDS, SDG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 S 9300, S 9500, S 9700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Mechanical Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Electrical Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Activities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Customer/Protective Barriers/EoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 Floor Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4 Maintenance Operating Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 Guard Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6 Maintenance Steps/Pallets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7 Handrail Entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8 Combplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 Step Level Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Relay Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 MICONIC F 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 MICONIC F 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 MICONIC F 3/4/5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents Copyright © 2014 INVENTIO AG
Q 43831001_00
4 4 5 6 12 13 14 15 15 16 17 18 18 20 29 29 31 32 33 35 36 40 41 45 46 46 49 54 60
3
1 1.1
General Information Introduction
The purpose of this troubleshooting guide is to provide the Schindler employee with an appropriate tool to make troubleshooting work easier. Only properly trained and authorized Schindler employees are permitted to operate or handle any portion of the equipment. This also applies to settings, adjustments, inspections, maintenance, repair and modernization.
The given instructions are for escalator and moving walks. To keep this troubleshooting guide as slim as possible only the wording “step” and “step axle” are used. At a moving walk with short pallets remove three pallets instead of one step. At a moving walk with long pallets proceed as described for steps.
This troubleshooting guide does not claim to include all possibilities. The Schindler employee has to read, understand and follow the instructions in this troubleshooting guide in any case. Do not disclose this troubleshooting guide to third parties. Return the troubleshooting guide to the line manager when requested. For any questions and suggestions please contact your local branch office or national master trainer.
General Information Copyright © 2014 INVENTIO AG
Introduction
Q 43831001_00
4
1 General Information 1.2 Safety Warnings The following types of safety warnings are used in the present manual. DANGER Danger The safety warning with the signal word “Danger” is used to indicate a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING Warning The safety warning with the signal word “Warning” is used to indicate a hazardous situation which, if not avoided, could result in death or serious injury.
NOTICE Notice The safety warning with the signal word “Notice” is used to address practices that could lead to property damage but not to injury.
General Information Copyright © 2014 INVENTIO AG
Safety Warnings
Q 43831001_00
5
1 General Information 1.3 Safety Guidelines DANGER Accidents or Operating Errors
DANGER Maintenance Operating Panel
Accidents or operating errors will lead to serious injury to persons and/ Before entering the pit: or damage to property. – Connect the maintenance operating panel Every precaution should be taken to prevent accidents and incorrect – Check the proper function of the movement – Activate the emergency stop button operation. – Check that no movement is possible. DANGER DANGER
Unexpected Movement of the Escalator Test Runs
Unexpected movement of the escalator will result in serious injury or death. Test runs during work performed on the unit represent an increased risk Lock out and tag out the main switch JHA while working inside the step to persons and components of the unit. In the course of work performed at the escalator or moving walk, trial band. runs should only be carried out with the maintenance operating panel. DANGER DANGER
Unexpected Movement of the Escalator Emergency Stop Button
Unexpected movement of the escalator will result in serious injury or death. As a matter of principle, always press the emergency stop button at the Always press the emergency stop button JHRE as long as the unit must location where work takes place. not be moved. This will prevent starting the unit by mistake.
General Information Copyright © 2014 INVENTIO AG
Safety Guidelines
Q 43831001_00
6
1 1.3
General Information Safety Guidelines DANGER
WARNING
Hazardous Voltage
Bypassing of Safety Devices and Safety Contacts
Contact with live parts will result in electric shock causing serious injury Any bypassing of safety-relevant devices could result in damage to the or death. installation or in serious injury or death. Take the following precautions: Bypassing the safety circuit without explicit instruction is Do not touch live parts. prohibited. Switch off the main switch JHA before starting to work on the unit. Always take appropriate safety measures if premeditated bypassing is necessary for specific work on the installation. Do not use bypassing of the safety devices if prohibited by local WARNING code. Local Health and Safety Regulations Always leave the installation with all bypassing disabled. Ignoring health and safety regulations could result in damage to the installation or in serious injury or death. WARNING Strictly follow the local health and safety regulations, which apply in No Passengers on the Unit During a Technical Test addition to the minimal health and safety regulations specified in this Passenger on the unit while running a technical test could result in manual. death or serious injury. Do not allow any passengers on the unit while running a technical test. WARNING Unauthorized Access Secure the unit against accidental or unauthorized access. Set up warning signs and barriers to alert passengers to the fact that the unit is not in use.
General Information Copyright © 2014 INVENTIO AG
Safety Guidelines
Q 43831001_00
7
1 General Information 1.3 Safety Guidelines Escalators with hollow step axles are identified by stickers on the guard plates.
NOTICE Do NOT Step onto the Hollow Step Axles If the escalator is equipped with hollow step axles, do not step directly onto the step axles. Observe the sticker in the escalator pit. Never step onto the step axles in the inclined section of the step band.
Since release of the EN115-1:2008 a “emergency service” with bridged safety relevant components like switches or sensors at units which were commissioned since 2008 is not permissible anymore. Controller older than MIC F 2: Supply voltage of safety circuit is 230 VAC. Controller MIC F 2/3/4/5: Supply voltage of safety circuit is 110 VAC or 24 VDC.
[45386; 01.05.2013]
General Information Copyright © 2014 INVENTIO AG
Safety Guidelines
Q 43831001_00
8
1 General Information 1.3 Safety Guidelines The Following Five Safety Rules must be Observed NOTICE
1
Electrostatic Sensitive Device Printed Circuit Boards (PCB) are equipped with electrostatic sensitive semiconductors. Thus beware of electrostatic discharge and direct contact with the semiconductors. Touch the control cabinet to ground yourself for electrostatic discharge. Do not directly touch the PCB components. Always use the original antistatic packing when transporting the PCBs.
2 3 4 5
Before starting installation work, put up barriers to protect passersby and "Out of Order" signs (if hinged floor covers are used, they must be properly opened and locked). As soon as a floor cover has to be removed (or folded up) and before entering the pit, connect the maintenance operating panel. Perform all trial runs with the maintenance operating panel. When carrying out maintenance work inside the step/pallet band, switch off and lock the main switch. Never turn on escalators or moving walks under load.
Only appropriate tools, devices and materials may be used. The specifications on the safety data sheet for lubricants (oils, greases, etc.) must be met.
General Information Copyright © 2014 INVENTIO AG
Safety Guidelines
Q 43831001_00
9
1 General Information 1.3 Safety Guidelines Turning by Hand WARNING Risk of Injury from Flywheel
1
Fingers might get hurt by the flywheel. Do not stick fingers under the flywheel.
10004259
Loosen the safety brake (1), if fitted. Loosen the service brake (2). Turn the flywheel (3). - The correct direction of rotation is indicated on the flywheel (3).
[29429; 26.06.2009]
1 2 3
Safety brake Service brake Flywheel
[46381; 21.12.2012]
General Information Copyright © 2014 INVENTIO AG
Safety Guidelines
Q 43831001_00
10
1 General Information 1.3 Safety Guidelines Safety Equipment
Industrial Helmet
Safety Goggles
Full Body Harness
Safety Shoes
Protective Gloves
Hearing Protection
All people involved must know and follow the company and local safety regulations. Protective clothing and appropriate safety equipment must be worn. General Information Copyright © 2014 INVENTIO AG
Safety Guidelines
Q 43831001_00
11
1 General Information 1.4 Protective Clothing 1 2 3 4 5 6
1 2 3
Industrial helmet Safety goggles Dust mask Kevlar sleeves Protective gloves Safety shoes
4 5
6 [29410; 23.07.2010]
General Information Copyright © 2014 INVENTIO AG
Protective Clothing
Q 43831001_00
12
1 General Information 1.5 Personal Protective Equipment Designation
Quantity
Dust mask
1
Safety goggles
1
Protective gloves, size “M”
ID. No. 50639223
1
Protective gloves, size “L”
ID. No. 50639224
1
Kevlar sleeves
ID. No. 50639221
1
Industrial helmet
1
Safety shoes
1
Safety lock
1
Safety harness
1
Reflective jacket
1
Hearing protection
1
First aid kit
1
General Information Copyright © 2014 INVENTIO AG
Personal Protective Equipment
Q 43831001_00
13
1 General Information 1.6 Abbreviations Abbreviation _ ∗ [∗∗] or [∗∗∗∗] [∗∗∗∗]/[∗∗∗∗] BMS Bus EoS MIC FCOM Flash Jumper PCB PA PB PT P2 P3 PEM50.Q PEM51.Q PEM52.Q PF1.Q General Information Copyright © 2014 INVENTIO AG
Abbreviation Blank space Wildcard character Display MICONIC F 5S or F 5E Alternating display Building management system Communication system Engineer on Site MICONIC Maintenance software Program, parameter and error memory Bridge between two male connectors Printed circuit board PCB in the external control cabinet PCB in the bottom control cabinet PCB in the top control cabinet PCB, contract-specific position PCB, contract-specific position PB for MICONIC F 5S PT for MICONIC F 5S PCB for MICONIC F 5E PCB for MICONIC F 1, F 2
Abbreviation
Explanation
RAM
Random access memory
RS-232
Interface for FCOM or BMS
RS-485 X2.9 - 13 Interface for connecting of PCBs
Abbreviations
RS-485 X5.1 - 4
Interface for BMS or ALCDG
SEMI5-Card
Memory card with access rights
0x0000
Number in hex format
T
Top
B
Bottom
L
Left
R
Right
M
Middle
Q 43831001_00
14
2 2.1
Identification of Units SW, SW 77, SWE The type of unit can be identified by the specific handrail entry. A B C
A [49166; 22.10.2013]
SW: Relay control, no handrail entry contacts SW: Relay control, handrail entry “mouse trap” SW77: Relay control, handrail entry “mouse trap”
B [49153; 21.10.2013]
C [49152; 21.05.2014]
Identification of Units Copyright © 2014 INVENTIO AG
SW, SW 77, SWE
Q 43831001_00
15
2 Identification of Units 2.2 SDS, SDG The type of unit can be identified by the specific handrail entry. A, B SDS: MICONIC F 2 control C
A [49169; 23.10.2013]
SDG: MICONIC F 2 control
B [49156; 21.10.2013]
C [49155; 21.10.2013]
Identification of Units Copyright © 2014 INVENTIO AG
SDS, SDG
Q 43831001_00
16
2 Identification of Units 2.3 S 9300, S 9500, S 9700 The type of unit can be identified by the specific handrail entry. A, B S 9300, S 9500: MICONIC F 3, F 4, F 5 control C
A [49159; 22.10.2013]
S 9300, S 9500, S 9700: MICONIC F 3, F 4, F 5 control
B [49161; 25.10.2013]
C [49164; 22.10.2013]
Identification of Units Copyright © 2014 INVENTIO AG
S 9300, S 9500, S 9700
Q 43831001_00
17
3 Components 3.1 Mechanical Components 28 27a
29
28
27b
29
1
26
3 4
25a 24
24
6
23
7
22
22 21
8 9
21
2 3 4 5 6
25b
5
23
1
26
2
7 8
20
20
9
11a
10 18
11b
12
12 13
13 14a
14b
15 15 17
16
17
Components
3
Motor
4
Gearbox
5
Drive chain
6
Drive shaft with optional safety brake
7
Handrail drive
8
Pressure belt / pressure chain
9
Handrail tensioning device
10
Lateral cladding
12
Truss
13
Handrail entry
14a Step chain tensioning device 14b Pallet chain tensioning device 15
Truss soffit
16
Combplate
17
MICONIC F 2, F 3, F 4, F 5 control cabinet
18
Newel chain
16 [49168; 11.04.2014]
Copyright © 2014 INVENTIO AG
Service brake
11b Pallet chain
10
18
Flywheel
2
11a Step chain
19
19
1
Mechanical Components
Q 43831001_00
18
3 Components 3.1 Mechanical Components 28 27a
29
28
27b
29
1
26
3 4
25a 24
24
6
23
7
22
22 21
8 9
21
2 3 4 5 6
25b
5
23
1
26
2
7 8
20
20
9
10 11a
18
Outer decking
20
Inner decking
21
Skirt panel
22
Handrail
23
Balustrade
24
Balustrade clamps
25a Steps 25b Pallets 26
Combplate lighting
27a Balustrade profile (design E) 27b Balustrade profile (design F)
19
19
19
10 18
28
Floor covers
29
Control cabinet
11b
12
12 13
13 14a
14b
15 15 17
16
17 16 [49168; 15.08.2014]
Components Copyright © 2014 INVENTIO AG
Mechanical Components
Q 43831001_00
19
3 Components 3.2 Electrical Components
TL
T
TR ML M MR
Top
TL
Top Left
TR
Top Right
B
Bottom
BL
Bottom Left
BR
Bottom Right
M
Middle
ML
Middle Left
MR
Middle Right
A
Additional
A
BL
B
T
BR
Electrical Components Overview [43831001_001; 19.05.2014]
Components Copyright © 2014 INVENTIO AG
Electrical Components
Q 43831001_00
20
3 Components 3.2 Electrical Components Abbreviation
Area
ALCDG CBA
T
D DH DH1
Component
Abbreviation
Area
Component
Graphic plain text display
GLMGB
Safety brake capacitor
GPH
Diode
GV
Blocking valve
HK
Radiator
HS
Heating element
BR, M, TL Stop button
Safety brake rectifier T
Soft starting device
DIG
Digital display
HWD-relay
DJH
Push button for triggering the main switch
INAK
TL, TR
Hardware watchdog
INBB
TL, TR
Brake lining monitor
DH-BO
Stop button provided by client
INBMG
TL, TR
Motor speed monitor
DH-BS
Stop button, building site
INHL
BL, BR
Handrail speed monitor
DHEN
For maintenance panel
INMH
TL, TR
Motor speed monitor
DRE
Inspection push button up, down
INVK
B, T
Step speed monitor
DRES
Reset key
IRAD
BR, TL
Radar for entrance monitoring
DS
Start button
ITH
B, T
PT 100 temperature sensor
G
Rectifier
IZ
T
Pulse counter
GBMW
Braking distance measurement device
Drive chain monitor
JA
T
Deactivation switch
GFU
T, A
Frequency converter
JB
T
Switch for brake release
GFU-C
T
Frequency converter, crawling
JD
T
Continuous operation switch
GFUP
T, A
Frequency converter Plus
JF1
T
Residual current circuit breaker
Manual control device inspection
JFIH
T
Main circuit fault current breaker
GHRE Components Copyright © 2014 INVENTIO AG
Electrical Components
Q 43831001_00
21
3 Components 3.2 Electrical Components Abbreviation
Area
JFIL
T
JHA
T
JHHE
T
JHL JHRE JH-US
Component
Abbreviation
Component
T
Brake contact
Main circuit breaker
KBB
T
Brake lining contact
Heating switch
KBF
B, T
Contact in case of fire by customer
T
Main lighting system switch
KBFM
B, T
Smoke detector
B, T
Inspection stop switch
KBSA
T
Safety brake active contact
B
Return station stop switch
KBSP
T
Safety brake passive contact
KBW
BR, BL
Handrail monitoring contact
KBZ
T
Additional brake contact
KDH
BR, TL
Stop push button cover contact
KDMR
B, T
Floor cover contact / Machine room cover contact
JH JH1
Area
KB
B, M, T
Stop button
JH2 JL
B, T
Pit lighting switch
JMo
T
Motor switch
JMZS
T
Motor automatic lubrication switch
KDZS
T
Automatic lubrication pressure contact
JRE
B, T
Inspection switch
KF
T
Speed regulator contact
KGGFU
T, A
Frequency converter in generator mode contact
JREM
B, T
Stop switch
JR
B, T
Direction key switch
JRES
B, T
Key switch reset
JS
B, T
Key switch
JSK
Safety circuit switch
KAK
TL, TR
Drive chain contact
KANK
T
Missing-step check contact
Components Copyright © 2014 INVENTIO AG
KGL
Glass cladding monitor
KHL
BR, BL
Handrail contact
KHLA
BR, BL
Handrail displacement contact
KHLE
BL, BR, TL, TR
Handrail entry contact
Electrical Components
Q 43831001_00
22
3 Components 3.2 Electrical Components Abbreviation
Area
Component
Abbreviation
Area
Component
KHLL
BR, BL
Handrail elongation contact
KTBB
KKA
B, T
Step broken contact
KTHM
T
Thermo motor contact
KKB
TR, TL
KTHR
T
Thermo controller contact
KUS
BL, BR, TL, TR
Step upthrust monitoring contact
LAG
B, T
Direction indicator green
LAR
B, T
KKE KKP
Broken drive chain contact
Balustrade lighting door contact
BL, BR, TL, TR
Combplate contact
BL, BR, TL, TR
Combplate contact horizontal
KKPV
BL, BR, TL, TR
Combplate contact vertical
LG
KKS
BL, BR
Step/pallet chain tension contact
LHL
Mat pressure contact
LKPE
BL, BR, TL, TR
KKPH
KMD
LBB
Direction indicator red Balustrade lighting
B, T
Machine room lighting / pit lighting lamp Handrail check lamp Combplate lamp
KMs
T
Anti-reversing lock contact
KOZS
T
Automatic lubrication oil level contact
LMG
T
Motor noise choke
KRL
T
Anti-reversing contact
LNF
T, A
Interference suppression filter
KSEIS
B, T
Seismic monitor
LSS
B, T
Step gap lamp
KSL
BL, BR, TL, TR, ML, MR
LV
M
Light curtain
Skirt contact
MB
T, A
Motor brake
KSOFU
T, A
Frequency converter fault contact
MF
T, A
Motor filter
KTHWFU
M, A
Braking resistor
MGBA
T
Solenoid safety brake
Components Copyright © 2014 INVENTIO AG
Electrical Components
Q 43831001_00
23
3 Components 3.2 Electrical Components Abbreviation
Area
Component
Abbreviation PHANK
Area
T
Solenoid brake passive
MGBZ
T
Solenoid brake supplement
MGRL
T
Anti-reversing solenoid
PHGPH
Photoelectric cell phase angle control Photoelectric cell step receiver
MGS
T
Solenoid valve lubrication
PHKE
MGP
T
Piston pump
PHKS
B, T
Component
MGBP
Photoelectric cell / proximity switch missing-step check
Photoelectric cell step transmitter
MGSKA
T
Drive chain lubrication valve
PHS
B, T
Skirt panel photocell
MGSKHL
T
Handrail drive chain lubrication valve
PHSE
Photoelectric cell skirting receiver Photoelectric cell skirting transmitter
MGSKS
T
Step chain lubrication valve
PHSS
MH
T
Main drive motor
PHSTE
MJH
T
Main switch trigger solenoid
Photoelectric cell passenger guide bars receiver
Mo
T
Motor
PHSTS
Photoelectric cell passenger guide bars transmitter
MS
T
Anti-reversing solenoid
MVEH
T
Fan motor heating
MZS
T
Motor automatic lubrication
NGLBB
B, T
Balustrade LED lighting power supply
P
B, T
Socket
PBL
B, T
Dummy inspection connector
PCBA PGH
Components Copyright © 2014 INVENTIO AG
Capacitor safety brake B, T
PHVE
B, T
PHVS
B, T
Scan sensors transmitter
PMVEH
T
Heating fan motor connector
PRE
B, T
Inspection socket
P-AS
T
Socket drive station
P-US
B
Socket return station
R
Manual control unit connector
RB
Electrical Components
Scan sensors receiver
Ballast resistor T
Relay service brake Q 43831001_00
24
3 Components 3.2 Electrical Components Abbreviation
Area
Component
Abbreviation
Area
Component
RBGA
T
Relay safety brake
RKL
T
PTC resistor
RBL
B, T
Relay lighting
RKPH
T
Relay phase monitoring
RBLD1
B, T
Relay activation delay illumination 1
RKPV
B, T
Combplate relay vertical
RE
T
Switch-on contactor circuit
RKu
T
Auxiliary relay to changeover relay
RFPH
T, A
Phase error relay
RLAG
B, T
Relay direction indicator green
RFUS
T, A
Relay selection speed
RMBth
T
RGBA
T
Relay safety brake
Thermal solenoid brake protection relay
RGF
T, A
Output relay electrical regulated brake down, up
RMGB
T
Safety brake relay
RMGSKA
T
Drive chain lubrication relay
RHBS
Relay stop by customer
RMGSKHL
T
Handrail drive chain lubrication relay
RHM
Relay signalling stop
RMGSKS
T
Step chain lubrication relay
RIZHL
Pulse counter relay handrail
RMGSP
T
Lubrication pump relay
RJH
T
Main contactor
RN
T
Voltage monitoring relay
RK
T
Auxiliary relay
RPHV
B, T
Scan sensors output relay
RKB
T
Brake release relay contact
RR-D/U
T
Relay direction down/up
RKBB
T
Brake lining relay contact
RRE-A
T
Relay maintenance off
RKBF
T
Fire contact relay
RRUN
T
Miconic F running relay
RKE
T
Auxiliary relay to switch-on contactor
RSF
T
Crawling relay
RKF
T
Relay for speed regulator / handrail monitor
RSFK
T
Frost protection signaling relay
RSFU
T, A
Frequency converter relay
Components Copyright © 2014 INVENTIO AG
Electrical Components
Q 43831001_00
25
3 Components 3.2 Electrical Components Abbreviation
Area
RSK
B, T
RSKM RSSL
Component
Abbreviation
Area
Component
Safety circuit relay
RZRL
T
Anti-reversing solenoid time delay
B, T
Signalling safety circuit relay
RZSPF
T
Time lock trip relay
B, T
Skirting strips signaling relay
RZth
T
Time delay relay star / delta
RTH
T
Thermal trigger block
RZU
T
Return protection relay
Rth
T
Thermal motor protection relay
RZYD
T
Star / delta time delay relay
RTHFK
B, T
Antifreeze controller combplates relay
SB
T
Brake contactor
RTHK
B, T
Temperature controller combplates relay
SBL
B, T
Balustrade lighting contactor
SBM
T
Service brake / safety brake contactor
RTZS
T
Automatic lubrication timing relay
SD
T
Delta connection / direct contactor
RU1
T
Changeover relay down
SDA
T
Contactor delta connection drive unit
RU2
T
Changeover relay up
SFE
T
Travel initiation contactor
RVEKA
T
Cooling fan relay
SFU
T
Frequency converter contactor
RVFU
T, A
Frequency converter output relay
SGBA
T
Active safety brake contactor
RVN
T
Main supply output relay
SGFB
T
Regulated brake electrical relay
RVR-D/U
T
Direction output relay down/up
SH
T
Main contactor
Rz
T
Time delay relay for star / delta change over
SHE
B, T
Heating contactor
SHL
B
Handrail monitor auxiliary contactor
SIBB
B, T
RZB
T
Time delay relay for handrail monitor
RZMs
T
Time delay relay for anti-reversing solenoid
Components Copyright © 2014 INVENTIO AG
SIBS
Electrical Components
Balustrade lighting fuse Main circuit fuse by customer
Q 43831001_00
26
3 Components 3.2 Electrical Components Abbreviation
Area
SIBS1
Component
Abbreviation
Light circuit fuse by customer
Area
SKVS
B, T
Component Speed check contactor software channel
SIF
B, T
Fine fuse
SIF1
B, T
22 VAC mains fuse
SMGSP
T
Lubrication pump fuse
T
Main contactor supply
SIF4
T
Valve for lubrication mains fuse
SN
SiG
T
Fuse for rectifier
SNBA
T
SIH
T
Main fuse
Active safety brake mains supply contactor
SIHK
B, T
Radiator fuse
SR-D/U
T
Direction contactor down / up
SIHS
B, T
Heating element fuse
SRE
T
Trip inspection contactor
SIL
B, T
Light system fuse
SNBA
T
Active safety brake mains supply contactor
SILS
B, T
Light circuit fuse
SR-D/U
T
Direction contactor down / up
SIMVA
B, T
Heating fan motor fuse
SUM
B, T
Buzzer
SIMVK-A
T
Cooling fan circuit breaker
SY
T
Star connection contactor
SIS
T
Control fuse
SYA
T
Star connection drive unit contactor
SiSg
T
Fuse for signals
SZS
T
Automatic lubrication contactor
SiTr
T
Primary fuse of control transformer
TA
T
Trimming transformer control
SIS3
T
Brake release circuit breaker
THFK
B, T
SK
T
Relay check contactor
Antifreeze protection combplates thermosensor
SKVH
B, T
Speed check contactor hardware channel
THK
B, T
Combplates thermosensor
THS
B, T
High-voltage transformer
TLBB
B, T
Balustrade lighting ballast
Components Copyright © 2014 INVENTIO AG
Electrical Components
Q 43831001_00
27
3 Components 3.2 Electrical Components Abbreviation
Area
Component
Tr
B, T
TS
B, T
Transformer control
TSP
T
Transformer lubrication piston pump
VMGB
T
Safety brake booster relay
VSD
T
Delta contactor booster relay
VSR
T
Direction contactor booster relay
VSY
T
Star contactor booster relay
VSZS
T
Lubrication contactor booster relay
W
T
Resistor 2K2
WFU
T, M
Brake resistor
WTHM
T
PTC resistor in motor winding
WVB
T, M
Ballest resistor to DC brake
ZQF
T
Trip counter
ZQH
T
Hours counter
Components Copyright © 2014 INVENTIO AG
Transformer
Electrical Components
Q 43831001_00
28
4 4.1
Activities Troubleshooting – Press the emergency stop button
WARNING Open Step / Pallet Band
– Connect the maintenance operating panel
Unit with open step / pallet band could result in death or serious injury. Never leave a unit with open step / pallet band. If no immediate repair is possible, reassemble all disassembled parts in reverse order.
– Lift out the control cabinet and open it – Unit older than MIC F 2: Check every safety contact with a continuity meter and the wiring diagram – Unit with digital display: Check the display for the error message. Refer to chapter “7 Error Messages” and follow the correction instructions
Notify the customer at arrival and at departure. If the unit is equipped with handrail entry type "mouse trap" check all four entries are closed. Check if the unit is equipped with a display which is visible from outside.
– Only at error message 28 or 36, refer to the chapter “Step Level Switch” – Check if the error related switch is mechanically locked
If the display is toggling showing [d0] and an error message: – Read the error message and refer to the chapter “7 Error Messages” – Check the mentioned area for trapped objects and correct switch / sensor setting.
– Confirm the error. Reassemble all disassembled parts in reverse order. Restart the unit by using the key switch.
If no display is present or the display do not show [d0]: – Set up protective barriers – Activate EoS – Unit older than MIC F 2: Remove the floor cover at the drive station – Unit with MIC F 2/3/4/5: Remove the floor covers at the tension station Activities Copyright © 2014 INVENTIO AG
Troubleshooting
Q 43831001_00
29
4 4.1
Activities Troubleshooting If the escalator does not start up when switched on, check:
– – – – – –
The main switch is turned on Both inspection switches are set to Normal Both inspection dummy plugs are connected and secured The fuses are OK The safety circuit is closed The relays and contactors are picked up.
If there is a failure of a step band light barrier, emergency operation can be started: – – – – – –
Switch off the main switch Disconnect the defective light barrier / proximity switch (terminal 115 or 116) Insert a jumper between terminals 115 or 116 Switch on the main switch Set DIL switch S10 to OFF position The defective light barrier must be renewed as quickly as possible, and the jumper removed.
If a combplate contact has tripped, it is essential to check there are still objects in the combs or under the combplate. If the contact on the step chain tensioning device has switched off and this is not clearly due to a slight elongation of the step chain, it LED Function Miconic F 1, F 2 PCB PF1.Q is essential to establish the cause. Unit Stopped LED Status Meaning If the escalator switched off again for about 4 ... 10 seconds after LED 3 red Flashes Safety circuit open being switched on, check the speed monitoring or the handrail monitor has tripped. DIL switch not in normal position LED 2 yellow
Flashes
Interlocked shutdown
LED 2 yellow
Lit
Unit ready to start
Unit Moving
Activities Copyright © 2014 INVENTIO AG
LED Status
Meaning
LED 1 green
Flashes
Startup bypass phase
LED 1 green
Lit
Rated operation
LED 2 yellow and LED 3 red
Alternate flashing Automatic lubrication fault
Troubleshooting
Q 43831001_00
30
4 4.2
Activities Customer/Protective Barriers/EoS A: Notify the customer of shutdown and start-up. B: Set up protective barriers before starting any work and remove them at the end of the work. C: Activate/deactivate EoS. - Press and hold the STOP button - Turn the key switch in up and down direction.
A [29414; 24.07.2013]
STOP
B [49102; 08.10.2013]
Activities Copyright © 2014 INVENTIO AG
C [49103; 08.10.2013]
Customer/Protective Barriers/EoS
Q 43831001_00
31
4 Activities 4.3 Floor Covers Removal and Reassembly 1
2
A
A: Lift the end cover (3). B: Rest the end cover (3) onto the safety shoe. C: Remove the end cover (3) using both hands. Remove the middle cover (2), if fitted. D: Loosen and slide the fixing nuts (4) on both sides of the connection cover (1). Pull the connection cover (1) horizontally and remove it.
3
B 3
1 2 3 4
Connection cover Middle cover (if present) End cover Fixing nut or wing nut (if present)
1
C
D
[35764; 11.04.2014]
Activities Copyright © 2014 INVENTIO AG
Floor Covers
Q 43831001_00
32
4 Activities 4.4 Maintenance Operating Panel Function Check DANGER Test Runs Test runs during work performed on the unit represent an increased risk to persons and components of the unit. In the course of work performed at the escalator or moving walk, trial runs should only be carried out with the maintenance operating panel. At SW, SW77 the maintenance operating panel is mounted in the top and bottom pit. 1
Maintenance operating panel
[29604; 06.04.2009]
Activities Copyright © 2014 INVENTIO AG
Maintenance Operating Panel
Q 43831001_00
33
4 Activities 4.4 Maintenance Operating Panel Function Check With the emergency stop button pressed, the unit must not start up. With MIC F 4 and higher controllers, "EoS" must be activated. Release the lock and remove the dummy plug. Connect and lock the maintenance operating panel (1): - Reading on the display: "r0". Press the enable button and one of the direction buttons to run the unit in the desired direction. Activate the emergency button. Check that no movement is possible. 1
Maintenance operating panel
[29604; 06.04.2009]
Activities Copyright © 2014 INVENTIO AG
Maintenance Operating Panel
Q 43831001_00
34
4 Activities 4.5 Guard Plate Removal and Reassembly Remove the control cabinet Remove the guard plate.
[35763; 23.07.2010]
Activities Copyright © 2014 INVENTIO AG
Guard Plate
Q 43831001_00
35
4 Activities 4.6 Maintenance Steps/Pallets Removal of Steps 4
3
Only at the tension station. Position the step (1) such that the step roller has just passed the removal recess (4). Mark the position of the step bushings (3). Loosen the straps (2). Shift the straps (2) and the step bushings (3) inward. Lift and remove the step (1).
2
Maintenance step with divided step axle Strap Step bushing Removal recess
10004335
1 2 3 4
1
[29508; 23.07.2010]
Activities Copyright © 2014 INVENTIO AG
Maintenance Steps/Pallets
Q 43831001_00
36
4 Activities 4.6 Maintenance Steps/Pallets Reassembly of Steps 4
3
Only at the tension station.
2
Maintenance step with divided step axle Strap Step bushing Recess
10005460
1 2 3 4
Insert the step rollers into the recesses (4). Attach the step (1) to the step axle. Insert the step bushings (3). Slide on the straps (2). Check if the step (1) is centered. Tighten the strap bolts to 10 Nm. Check if the step (1) is secured without play.
1
[30297; 23.07.2010]
Activities Copyright © 2014 INVENTIO AG
Maintenance Steps/Pallets
Q 43831001_00
37
4 Activities 4.6 Maintenance Steps/Pallets Removal of Short Pallets Remove the M5x20 screws with washers (1). Lift the pallet (2) off, but do not turn it upside down. Remove the pallet holder (3).
1
2
1 2 3
M5x20 screw with washer Pallet Pallet holder
3
[29510; 03.04.2009]
Activities Copyright © 2014 INVENTIO AG
Maintenance Steps/Pallets
Q 43831001_00
38
4 Activities 4.6 Maintenance Steps/Pallets Reassembly of Short Pallets NOTICE Pallet Fastening Screws 2
Pallet fastening screws can only be used once. Fasten the pallets only with new fastening screws. Insert pallet holders (3) alternately into the inner and outer link plates. Insert the pallets (1). All arrows must point in the same direction. Screw in the M5x20 screws with washers (2) and tighten them to 10 Nm.
1
1 2 3
Pallets M5x20 screw with washer Pallet holder
10004338
3
[29511; 23.07.2010]
Activities Copyright © 2014 INVENTIO AG
Maintenance Steps/Pallets
Q 43831001_00
39
4 4.7
Activities Handrail Entry Function Check Check handrail entries for trapped objects. For “mouse trap”: Check that the three flaps are closed. Check that the gap between the handrail entry and the handrail is uniform on all sides.
[29597; 10.10.2013]
Activities Copyright © 2014 INVENTIO AG
Handrail Entry
Q 43831001_00
40
4 4.8
Activities Combplate Combplate The unit must be put out of operation if two or more adjacent teeth are broken. Check combplate for trapped objects. Check that not two or more adjacent teeth of the combs are broken.
Variant 1: Function Check The contact must be triggered by moving the combplate. Actuate only one KKP contact at a time, the triggered KKP contact must prevent the unit from starting up: - Error "10": KKP-T - Error "15": KKP-B. A B
5 mm
C
A B C
Block Roller Combplate contact KKP
[46599; 23.09.2013]
Activities Copyright © 2014 INVENTIO AG
Combplate
Q 43831001_00
41
4 4.8
Activities Combplate Variant 2: Function Check The contact must be triggered by moving the combplate. Actuate only one KKP contact at a time. The triggered KKP contact must prevent the unit from starting up: - Error "10": KKP-TL - Error "15": KKP-BL - Error "4A": KKP-TR - Error "4b": KKP-BR.
4 mm
1
Combplate contact KKP
1
[46571; 20.11.2013]
Activities Copyright © 2014 INVENTIO AG
Combplate
Q 43831001_00
42
4 4.8
Activities Combplate Variant 3: Function Check Actuate only one contact at a time. The triggered contact must prevent the unit from starting up: - Error "10": KKP-TL - Error "15": KKP-BL - Error "4A": KKP-TR - Error "4b": KKP-BR - Error "23": KKPYV-T - Error "29": KKPYV-B.
3
2
10 mm
9.5 mm
1
1 2 3
Combplate contact, horizontal KKP Combplate contact, vertical KKPYV (optional) Contact NYC RS-18 (optional)
[30292; 25.09.2013]
Activities Copyright © 2014 INVENTIO AG
Combplate
Q 43831001_00
43
4 4.8
Activities Combplate Variant 4: Function Check Actuate only one contact at a time. The triggered contact must prevent the unit from starting up: - Error "10": KKP-TL - Error "15": KKP-BL - Error "4A": KKP-TR - Error "4b": KKP-BR - Error "23": KKPYV-T - Error "29": KKPYV-B. 2
1 2
Combplate contact, horizontal KKP Combplate contact, vertical KKPYV (optional)
10.2 mm
1 [46504; 09.12.2013]
Activities Copyright © 2014 INVENTIO AG
Combplate
Q 43831001_00
44
4 4.9
Activities Step Level Switch Only at error message 28 or 36.
Check if the step level switch has triggered at bottom (error message 28) or top (error message 36). Mark the step at the area of the triggered step level switch. Confirm the error message on the controller. Only if the error persists: - Switch off the main switch - Bridge out the triggered step level switch at the respective controller - Remove the feedback signal of the triggered step level switch at the respective controller - Switch on the main switch. Move the marked step to the tension station with the maintenance operating panel. Check three steps before and after the marked step as well as the marked step for any damage: - Step deformed / damaged - Step hook deformed / broken - Step roller defective - Step roller bearing defective - Step chain roller defective - Step axle deformed. Change damaged steps / rollers immediately. Activities Copyright © 2014 INVENTIO AG
Only if the triggered step level switch is bridged out: - Remove one maintenance step - Drive the step gap to the triggered step level switch - Switch off the main switch - Remove the bridge at the controller - Reconnect the feedback signal - Place the step level switch into the correct position - Switch on the main switch - Move the step band one full turn with the maintenance operating panel to verify the correct function. Reassemble all disassembled parts in reverse order. Restart the unit by using the key switch.
Step Level Switch
Q 43831001_00
45
5 5.1
Error Messages Relay Control Only type SWE.
Display
Error Message
Abbreviation
[00]
In operation
OK
[00]
Signaling stop relay
RSH
[01]
Signaling phase relay
RSPH
[02]
Step chain tension contact, left/ right
KKS-L/R
[03]
Check dropping contact, bottom
KKA-B
[04]
Handrail entry contact, bottom left/ KHLE-B L/R right
Error Messages Copyright © 2014 INVENTIO AG
Note
Correction
Check: Step band Contact setting Spring tension
Relay Control
Measure all three phases to ground Check direction of rotation of main line
Check KKA-B relay drops out
Check: Handrail entry: – For trapped objects – For damage – For correct setting Contact setting
Q 43831001_00
46
5 5.1
Error Messages Relay Control
Display
Error Message
Abbreviation
[05]
Combplate contact, bottom left/ right
KKP-B L/R
[06]
Signaling skirt strip relay, bottom
RSSL-B
[07]
Signaling skirt strip relay, left
RSSL-L
[08]
Main power supply
JHA
[10]
Speed check contactor
SVK
[20]
Drive chain contact, left/right
KAK-L/R
Note
Correction Check: Combs for damage Step for damage (before and beneath the combplate) Combplate: – returns to its initial position – side adjusting screws are set too tightly – touches skirt panel – antilift screws are set too tightly – support plate is very dirty
Release safety brake (if installed)
Check: Chain tension Chain for excessive elongation Chain damage [30]
Check dropping contact, top
Error Messages Copyright © 2014 INVENTIO AG
KKA-T
Relay Control
Check KKA-T relay drops out
Q 43831001_00
47
5 5.1
Error Messages Relay Control
Display
Error Message
Abbreviation
Note
Correction
[40]
Handrail entry contact, top left/ right
KHLE-T L/R
See [04]
[50]
Combplate contact, top left/right
KKP-T L/R
See [05]
[60]
Signaling skirt strip relay, top
RSSL-T
[70]
Signaling skirt strip relay, right
RSSL-R
[80]
Signaling PTC resistor relay
RSKL
Check motor temperature
[90]
Auxiliary brake contact
KBZ
Error Messages Copyright © 2014 INVENTIO AG
Check: Power supply of brake motor Brake motor for malfunction
Relay Control
Q 43831001_00
48
5 5.2
Error Messages MICONIC F 1 To confirm interlock errors: – Switch S11 ON and OFF.
Display
Error Message
Abbreviation
Note
Correction
[-.-]
Displacement error warning
PHKE
[00]
Key switch not in operative position
JR-U JR-T
[10]
Combplate contact top
KKP-T
Check: Combs for damage Step for damage (before and beneath the combplate) Combplate: – returns to its initial position – side adjusting screws are set too tightly – touches skirt panel – antilift screws are set too tightly – support plate is very dirty
[11]
Handrail entry contact top
KHLE-T
Check: Handrail entry: – For trapped objects – For damage – For correct setting Contact setting
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 1
Check key switch
Q 43831001_00
49
5 5.2
Error Messages MICONIC F 1
Display
Error Message
[12]
Skirting contact
[13]
HWD fault
[14]
Emergency stop
[15] [16]
Abbreviation
Note
KSL
Correction Check: Objects trapped between step and skirting Visible damage of steps or skirting
DH
Check stop button for damage
Complate contact bottom
KKP-B
See [10]
Handrail entry contact bottom
KHLE-B
See [11]
[17]
Step Chain tension contact
KKS-B
[20]
ROM check error
[21]
Missing step
KANK
Check: Step / pallet band for completeness and damage Sensors Sensor setting Power supply of sensor
[22]
Smoke detector
KBFM
Check: Smoke formation Cause of smoke Respective component
Error Messages Copyright © 2014 INVENTIO AG
Check: Step band Contact setting Spring tension Interlocked
MICONIC F 1
Q 43831001_00
50
5 5.2
Error Messages MICONIC F 1
Display
Error Message
Abbreviation
Note
Correction
[23]
Safety brake contact
KBSP
[24]
PTC resistor
WTHM
[25]
Contact dropout check
[26]
Wrong direction of rotation
PHKE
Interlocked
[27]
Deviation value exceeded
PHKE
Interlocked
[30]
Overspeed
PHKE
Interlocked
[31]
Underspeed
PHKE
Interlocked
[32]
Handrail monitor left
INHL-L
[33]
Handrail monitor right
INHL-R
[34]
Service brake contact
KB
Phase failure
RKPH
Measure all three phases to ground Check direction of rotation of main line
Active safety brake
KBSA
See [23]
[35] Error Messages
Copyright © 2014 INVENTIO AG
Check: Pawl setting Pawl for free movement Lifting solenoid of pawl
Check motor temperature
Check: Motor, SKV, SRE contactors are in off position SFE contactor picked up
Check function and setting of PHKE, PHNK-T and PHNK-B
Check: Sensors Handrail speed Try to stop handrail manually Check: Power supply of brake motor Brake motor for malfunction
MICONIC F 1
Q 43831001_00
51
5 5.2
Error Messages MICONIC F 1
Display [36]
Error Message
Abbreviation
Note
Correction
Step sag check
KKA
Smoke detector
KBFM
[37]
Step missing
PHKE
Interlocked
[39]
Missing step/pallet, top
PHANK-T
Interlocked
[3A]
Light scanner error top
PHANK-T
[3B]
Missing step/pallet, bottom
PHANK-B
[3C]
Light scanner error bottom
PHANK-B
[40]
Reset
[41]
See chapter “Step Level Switch”
Check: Smoke formation Cause of smoke Respective component
See [26]
Key switch top
Check key switch
[42]
Voltage drop 24 VDC
Check 24 VDC
[43]
Current limiter responded
[44]
RAM check error
Set parameter according to control cabinet sticker
[45]
SRE drop check error
Close inspection cover Activate EoS Open inspection cover Check function of RRE-A, SRE-A JREMACT is off
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
MICONIC F 1
Q 43831001_00
52
5 5.2
Error Messages MICONIC F 1
Display
Error Message
Abbreviation
[46]
Step band monitor inactive
S10
[47]
Light beam error
PHKE
[88]
Undefined shutdown
Error Messages Copyright © 2014 INVENTIO AG
Note Interlocked
MICONIC F 1
Correction
See [26]
Q 43831001_00
53
5 5.3
Error Messages MICONIC F 2 To confirm interlocked errors:
Switch S11 ON and OFF If the error persists: – Switch S11 to ON position – Switch the main switch off and on – Switch S11 to OFF position.
Display
Error Message
Abbreviation
[-.-]
Displacement error warning
PHKE
[00]
Key switch not in operative position
JR-U JR-D
[10]
Combplate contact, top
KKP-T KKPV-T
Error Messages Copyright © 2014 INVENTIO AG
Note
Correction
Interlocked
MICONIC F 2
Check key switch
Check: Combs for damage Step for damage (before and beneath the combplate) Combplate: – returns to its initial position – side adjusting screws are set too tightly – touches skirt panel – antilift screws are set too tightly – support plate is very dirty
Q 43831001_00
54
5 5.3
Error Messages MICONIC F 2
Display
Error Message
Abbreviation
Note
Correction
[11]
Handrail entry contact, top
KHLE-T
Check: Handrail entry: – For trapped objects – For damage – For correct setting Contact setting
[12]
Skirting contact, top
KSL-T
Check: Objects trapped between step and skirting Visible damage of steps or skirting
[13]
HWD error
HWD-relay SKVS
[14]
Emergency stop
DH
[15]
Combplate contact, bottom
KKP-B KKPV-B
[16]
Handrail entry contact, bottom
KHLE-B
[17]
Step chain tension contact
KKS-B
Check: Step band Contact setting Spring tension
Upthrust contact
KUS
Check for trapped objects: Between two adjacent steps Between steps and skirting
[18]
Interlocked
Combplate contact horizontal, top KKPH-T
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 2
Check stop button for damage
See [10]
See [11]
See [10] Q 43831001_00
55
5 5.3
Error Messages MICONIC F 2
Display [19]
Error Message Drive chain contact
Abbreviation
Note
Correction
KAK
Release safety brake (if installed)
Check: Chain tension Chain for excessive elongation Chain damage [1A]
Smoke detector
KBFM
Check: Smoke formation Cause of smoke Respective component
[1b]
Handrail displacement contact
KHLA
Check handrail: Breakage or damage Tension
[1C]
Combplate contact horizontal, bottom
KKPH-B
[1d]
Upthrust contact
KUS
[1E]
Combplate heating
RTHFK-T/B RSFK-T/B
[1F]
Skirting contact, bottom
[20]
ROM check error
Error Messages Copyright © 2014 INVENTIO AG
See [10]
Check for trapped objects: Between two adjacent steps Between steps and skirting
Remove ice and snow from combplate
Check: Heating element PT100 sensor
KSL-B
See [12]
Interlocked MICONIC F 2
Q 43831001_00
56
5 5.3
Error Messages MICONIC F 2
Display
Error Message
Abbreviation
[21]
Safety brake
KBSA KBS1A
[23]
Safety brake contact
KBSP KBS2A
[24]
PTC resistor
WTHM
[25]
Contactor release check
[26]
Rotation direction error
[27]
Displacement value exceeded
[28]
Step level contact, bottom
[2A]
Stop switch
[2b] [2d] [2F]
Note
Correction Check: Pawl setting Pawl for free movement Lifting solenoid of pawl
Check motor temperature
Check: Motor, SKV, SRE contactors are in OFF position SFE contactor picked up
Check function and setting of PHKE, PHANK-B and PHANK-T
KKA-B
See chapter “Step Level Contact”
JH-T/B/ A
Release JH-T
Handrail elongation contact
KHLL
See [1b]
Defect frequency converter
GFU
Check error message at GFU Bypass device, if defective
Floor cover contact, top
KD-T
Error Messages Copyright © 2014 INVENTIO AG
PHKE
Interlocked
Check: Proper fit of floor cover in frame Contact setting
MICONIC F 2
Q 43831001_00
57
5 5.3
Error Messages MICONIC F 2
Display
Error Message
Abbreviation
[30]
Overspeed
[31]
Underspeed
[32]
Handrail monitor, left
INHL-L
[33]
Handrail monitor, right
INHL-R
[34]
Service brake contact
KB
Phase failure
RKPH
[35]
Safety brake contact
[36]
PHKE
Note Interlocked
Interlocked
Correction
See [26]
Check: Sensors Handrail speed Try to stop handrail manually Check: Power supply of brake solenoid Brake solenoid for malfunction
Measure all three phases to ground Check direction of rotation of main line
KBSA KSBS1A
See [21]
Step level contact
KKA-T KKA-B
See [28]
Smoke detector
KBFM
See [1A]
See [26]
Check sensor Sensor setting Perform technical test [t_13]
Pallet monitor
KANK
[37]
Step absence
PHKE
Interlocked
[38]
Speed monitor
PFVK.Q INBMG
Interlocked
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 2
Q 43831001_00
58
5 5.3
Error Messages MICONIC F 2
Display
Error Message
Abbreviation
Note
[39]
Step absence, top
PHANK-T
[3A]
Initiator error, top
PHANK-T
[3b]
Step absence, bottom
PHANK-B
[3C]
Initiator error, bottom
PHANK-B
[40]
Reset
[41]
Key switch, stop
Start the unit
[42]
Voltage drop 24 VDC
Check 24 VDC
[43]
Current limit triggered
[44]
RAM check error
Set parameter according to control cabinet sticker
[45]
SRE drop check error
Close inspection cover Activate EoS Open inspection cover Check function of RRE-A, SRE-A JREMACT is off
[46]
Step band monitor
S10
[47]
Light barrier error
PHKE
See [26]
[4E]
Floor cover contact, bottom
KD-B
See [2F]
[88]
Undefined shutdown
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
Correction
Interlocked
Interlocked
MICONIC F 2
Check: Step / pallet band for completeness and damage Sensors Sensor setting Power supply of sensor See [26]
Q 43831001_00
59
5 5.4
Error Messages MICONIC F 3/4/5 To confirm interlocked errors:
Press the OK button on the PCB.
Display MIC F 3/4/5E:
Display [E_01] [01] [E_02]
Display MIC F 5S:
Error Message PT: 24 VDC short circuit
Abbreviation
PB: 24 VDC short circuit
P0B
[E_03]
PA: 24 VDC short circuit
P0A
[E_04]
PT: 24 VDC short circuit
P0T
[E_05]
PB: 24 VDC short circuit
P0B
Error Messages Copyright © 2014 INVENTIO AG
Note
Correction
P0T
Interlocked
MICONIC F 3/4/5
Check +24 VDC at the corresponding PCB
Q 43831001_00
60
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_10] [10]
Combplate contact, top left
KKP-TL
MIC F 3 ≤ V3.3 US Check: version: Interlocked Combs for damage Step for damage (before and beneath the combplate) Combplate: – returns to its initial position – side adjusting screws are set too tightly – touches skirt panel – antilift screws are set too tightly – support plate is very dirty
[E_11] [11]
Handrail entry contact, top left
KHLE-TL
MIC F 3 US Check: version: Interlocked Handrail entry for trapped objects Rubber collar for damage Rubber collar for correct setting Contact setting
[E_12] [12]
Skirt contact, top
KSL-T
[E_13]
Monitoring contactor, bottom
SKVB
Check that SKVB picks up
[E_14] [14]
Emergency stop
DH
Check stop button for damage
[E_15] [15]
Combplate contact, bottom left
KKP-BL
See [E_10]
Error Messages Copyright © 2014 INVENTIO AG
Check: Objects trapped between step and skirting Visible damage of steps or skirting
MIC F 3 ≤ V3.3 US version: Interlocked
MICONIC F 3/4/5
Q 43831001_00
61
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_16] [16]
Handrail entry contact, bottom left KHLE-BL
MIC F 3 US version: Interlocked
[E_17] [17]
Step chain tension contact
KKS-B
Interlocked
Check: Step band Contact setting Spring tension
[E_18] [18]
15 % motor overspeed
INBMG INMH-R
Interlocked
Check: Sensor Sensor setting All three phases of motor to ground MIC F 3/4: Perform technical test [t_13] MIC F 5E: Speed via [A_31], [A_32]
[E_19] [19]
Drive chain contact, top right
KAK-T KAK-TR INAK-TR
Interlocked
[E_1A]
Smoke detector, top
Error Messages Copyright © 2014 INVENTIO AG
KBFM-T
MICONIC F 3/4/5
See [E_11]
Release safety brake (if installed)
Check: Chain tension Chain for excessive elongation Chain damage Check: Smoke formation Cause of smoke Respective component
Q 43831001_00
62
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_1b]
Error Message
Abbreviation
Note
MIC F 3/4: Handrail displacement contact
Correction Check handrail: Breakage or damage Tension
KHLA
MIC F 5E: Handrail rupture, left
KHLB-L
[E_1C] [1C]
Motor underspeed
INBMG INMH-R
[E_1d]
Step upthrust contact, top
KUS-T
[1d]
Stop button, top
JH-T
Release JH-T
Combplate heating, bottom
RTHFK-B ITH-B
Remove ice and snow from combplate
[E_1E]
Interlocked
See [E_18]
Check for trapped objects: Between two adjacent steps Between steps and skirting
Check: Heating element MIC F 4/5E: PT100 sensor
See [E_12]
[E_1F] [1F]
Skirt contact, bottom
KSL-B
[E_20]
Contact flywheel cover
KHR
[E_21]
Emergency pull switch
KHRL
Check cable pull for proper operation Manually release the switch
[E_22]
Stop button 1, top
JH1-T
Release JH1-T
Error Messages Copyright © 2014 INVENTIO AG
Check: Flywheel cover is properly fastened Contact setting
MICONIC F 3/4/5
Q 43831001_00
63
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_23]
Error Message
Abbreviation
Note
MIC F 3: Stop button 2, top
JH2-T
MIC F 4/5E: Combplate contact, vertical, top
KKPYV-T
[E_24] [24]
PTC resistor, top
WTHM-T
[E_25] [25]
Contactor dropout check
SFE
[E_26]
Rotation direction error
INVK
[E_27]
Stop button 1, bottom
JH1-B
[E_28] [28]
Step level contact, bottom
KKA-B
Error Messages Copyright © 2014 INVENTIO AG
Correction
Release JH2-T
See [E_10]
Check motor temperature MIC F 3/4: With PES versions A to C, connect the PTC resistor between 1 and A2 (instead of 2)
Check: Motor, SKV, SRE contactors are in OFF position SFE contactor picked up Interlocked
MIC F 4/5: Interlocked
MICONIC F 3/4/5
Check: Sensors Sensor setting MIC F3/4/5E: Perform technical tests [t_05], [t_06] Power supply of sensor
Release JH1-B
See chapter “Step Level Switch”
Q 43831001_00
64
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_29]
Error Message
Abbreviation
MIC F 3: Stop button 2, bottom
JH2-B
Note
Correction
Release the JH2-B
See [E_10]
Release JH-T
See [E_1b]
MIC F 4/5E: Combplate contact, bottom vertical
KKPYV-B
[E_2A] [2A]
Stop button, top
JH-T
[E_2b]
MIC F 3/4: Handrail elongation contact
KHLL
MIC F 5E: Handrail rupture, right
KHLB-R
[E_2C] [2C]
Stop button, bottom
JH-B
Release JH-B
[E_2d] [2d]
Controlled drive failure
GFU GPH KSGFU
Check error message at GFU Bypass device, if defective
[E_2E]
Stop button, external control cabinet
JH-A
Release JH-A
[E_2F] [2F]
Floor cover contact, top
KDMR-T
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Check: Proper fit of floor cover in frame Contact setting Q 43831001_00
65
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_30] [30]
15 % overspeed
INVK-T INVK-B
Interlocked
[E_31] [31]
Underspeed
INVK-T INVK-B
Interlocked
[E_32] [32]
Handrail monitor, left
INHL-L
[E_33] [33]
Handrail monitor, right
INHL-R
Check: Sensors MIC F 3 US Perform technical test [t_07] version: Interlocked Handrail speed Try to stop handrail manually
[E_34] [34]
Service brake contact
MGB-L
[E_35] [35]
Safety brake
MGBA-L
[E_36] [36]
Step level contact, top
KKA-T
[E_37]
Stop button 1, external control cabinet
JH1-A
Error Messages Copyright © 2014 INVENTIO AG
MIC F 5 V54XX: Interlocked
See [E_26]
Check: Drive chain for damage Main contactors pick up All three phases of motor to ground See [E_26]
Check: Power supply of brake solenoid Brake solenoid for malfunction Check: Pawl setting Pawl for free movement Lifting solenoid of pawl
MIC F 4/5: Interlocked
MICONIC F 3/4/5
See [E_28]
Release JH1-A
Q 43831001_00
66
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
[E_38]
MIC F 3/4/5S:
[38]
Initiator for braking distance measurement
Abbreviation INBMG
Note Initiator defect
MIC F 5E: Drive motor initiator, right
INMH-R
[E_39] [39]
Missing step/pallet, top
INVK-T INMH-R
[E_3A] [3A]
Initiator defective, top
INVK-T
[E_3b] [3b]
Missing step/pallet, bottom
INVK-B INMH-R
[E_3C] [3C]
Initiator defective, bottom
[E_3d]
Interlocked
Correction
Check sensor Sensor setting MIC F 3/4: Perform technical test [t_13]
See [E_18]
Check: Step / pallet band for completeness and damage See [E_26]
See [E_26]
See [E_39]
INVK-B
See [E_26]
Monitoring contactor, top
SKVT
Check that SKVT picked up
[E_3E] [3E]
15 % overspeed
INVK-T INVK-B
Interlocked
See [E_26]
[E_3F] [3F]
Underspeed
INVK-T INVK-B
Interlocked
See [E_31]
[E_40] [40]
Contactor dropout check
SFE
Check if motor and brake contactors are dropped out
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
MICONIC F 3/4/5
Q 43831001_00
67
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
[E_41] [41]
Key switch stop
[E_42]
MIC F 3: Stop button 2, external control cabinet
Abbreviation
JH2-A
MIC F 4/5E: Skirt contact, middle section, top
KSLM-T
[E_43]
Oil level, drive motor
KOMH
[E_44] [44]
Parameters lost
[E_45]
RRE-A dropout check error
RRE-A
[45]
SRE-A dropout check error
SRE-A
Inspection outlet cover open [E_46]
Handrail drive chain
Error Messages Copyright © 2014 INVENTIO AG
KHLK
Note
Correction
Start the unit
Release the JH2-A
See [E_12]
Wait for 5 minutes Check oil level of gear box
Set parameter according to control cabinet sticker
Close inspection cover Activate EoS Open inspection cover Check function of RRE-A, SRE-A JREMACT is off
Check: Chain tension Chain for excessive elongation Chain for breakage
MICONIC F 3/4/5
Q 43831001_00
68
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_47]
Error Message
Abbreviation
Note
MIC F 3/4: External shutdown
Check input for STOP-BS
Restart unit
MIC F 3 US version: Interlocked
See [E_11]
MIC F 3 ≤ V3.3 US version: Interlocked
See [E_10]
STOP_ BS
MIC F 5E: Remote stop
JREMSTOP
[E_48] [48]
Handrail entry contact, top right
KHLE-TR
[E_49] [49]
Handrail entry contact, bottom right
KHLE-BR
[E_4A] [4A]
Combplate contact, top right
KKP-TR
[E_4b] [4b]
Combplate contact, bottom right
KKP-BR
[E_4C]
Safety circuit interruption
RSK
[E_4d]
DC901
[E_4E] [4E]
Floor cover contact, bottom
[E_4F] [4F]
Shutdown
Error Messages Copyright © 2014 INVENTIO AG
Correction
Check: PCB connector for proper fit Voltage along safety circuit
KDMR-B
MICONIC F 3/4/5
See [E_2F]
Restart unit
Q 43831001_00
69
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_50] [50]
Handrail monitor, left
INHL-L
[E_51] [51]
Handrail monitor, right
INHL-R
[E_52]
Entrance monitoring
IRAD-T IRAD-B
Check: Entrance monitoring (radar, light sensors, passenger guide bar light barriers) Activate display of operating data [A_03]
[E_53]
Seismic monitor
SEIS KSEIS
Check Relay External evaluation
[E_54]
Pit light barrier
PHTK_B
Check Reflector Setting of light barrier
[E_55]
Braking resistor
WFU KTHWFU
Check: Soiling Short circuits to ground Resistance value
[E_56]
Glass cladding monitor
RKGL KGL
Check Proper seat of glass panel Contact setting
[E_57] [57]
Engineer on Site
EoS
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
See [E_32]
Check if error is interlocked
Q 43831001_00
70
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_58]
Light curtain active too long
SLP1 LV1-PE LV2-PE
Check: Display of light curtain controller for defective light barriers Step band in the displayed light curtain area for cause of error Replace defective light barrier
[E_62] [62]
Crawling speed too slow
GFU GFU-C INBMG
Check: Mechanical movement of unit Power of unit without load Parameter of GFU, GFU-C Function of GFU, GFU-C, INBMG
[E_63]
Water level monitor, top
KWS-T
Check drive station pit for water
DH-B
Check stop button
[E_64]
Emergency stop, bottom
[E_65]
Start command pending
[E_66]
Remote stop via communication
[E_67]
PA: System status
[E_68]
PB-PA: System check
[E_69]
PA-PT: System check
[E_6A]
PA-PB: System check
[E_6b]
PT-PA: System check
Error Messages Copyright © 2014 INVENTIO AG
Check: Key switches or start button for damage Connection to BMS
MICONIC F 3/4/5
Check connection to BMS
Check parameter setting
Q 43831001_00
71
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_6C] [6C]
SB dropout check
I-SB
Check function of SB
[E_6d] [6d]
SR-U dropout check
I-SR-U
Check function of SR-U, SR1-U
[E_6E] [6E]
SR-D dropout check
I-SR-D
Check function of SR-D, SR1-D
[E_6F] [6F]
Dropout check motor contactors
I-SANTR
Check function of SY, SD, SFU, SN
[E_70]
SGBF dropout check
I-SGBF
Check function of SGBF
[E_71]
SR1-U dropout check
I-SR1-U
Check function of SR-U, SR1-U
Check function of SR-D, SR1-D
See [E_34]
Restart unit
See [E_19]
[E_72]
SR1-D dropout check
I-SR1-D
[E_73] [73]
Service brake dropout check
MGB MGB-L
[E_74]
Drive shut down
MIC F 5 V54XX: Interlocked
[E_75]
Drive chain contact, top left
INAK-TL KAK-TL
[E_76]
Overheat monitoring of truss
PB board X6.1
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
MICONIC F 3/4/5
Check: LHDC cable for short circuit 24 VDC 2 ... 6.4 VDC at PB X6.1
Q 43831001_00
72
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_77]
[E_78]
Error Message
Abbreviation
Note
Evacuation
End of evacuation
Correction Check: Safety relay Inputs
I-EVAK1 I-EVAK2 Interlocked
Check: Reason for evacuation travel Error history
[E_79]
Fuse 110 VAC
SIS2
Check 110 VAC control voltage
[E_7A]
Fuse main motor
SIHM
[E_7b]
Stop button, customer provided
DH-BS2
Check customer provided stop button
See [E_34]
Check: Main motor fuses Equal load conditions at double drive
[E_7C] [7C]
Service brake dropout check
MGB-L
[E_7d] [7d]
SB dropout check
I-SB
Check SB
[E_7E] [7E]
SR-U dropout check
I-SR-U
Check SR-U, SR1-U
[E_7F] [7F]
SR-D dropout check
I-SR-D
Check SR-D, SR1-D
[E_80] [80]
Dropout check of motor contactors I-SANTR
Check SY, SD, SFU, SN
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
MICONIC F 3/4/5
Q 43831001_00
73
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_81] [81]
Error Message
Abbreviation
Note
Correction
SB pickup check
I-SB
Check SB picks up during travel
SR-U pickup check
I-SR-U
Check SR-U, SR1-U pick up during travel
SR-D pickup check
I-SR-D
Check SR-D, SR1-D pick up during travel
Pickup check of motor contactors
I-SANTR
Check SY, SD, SFU, SN pick up during travel
[E_89] [89]
RB contactor dropout check
RB
Check RB relay drops out
[E_8A] [8A]
Motor underspeed
INMH-R
See [E_18]
[E_82] [82] [E_83] [83] [E_84] [84] [E_85] [85] [E_86] [86] [E_87] [87] [E_88] [88]
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
MICONIC F 3/4/5
Q 43831001_00
74
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
[E_8b] [8b]
15 % motor overspeed
INMH-R
Interlocked
See [E_18]
[E_8C] [8C]
30 % motor overspeed
INMH-R
Interlocked
See [E_18]
[E_8d] [8d]
Floor cover contact, top
KDMR-T
[E_8E] [8E]
Floor cover contact, bottom
KDMR-B
See [E_2F]
[E_8F] [8F]
Step level contact, top
KKA-T
[E_90] [90]
Step level contact, bottom
KKA-B
See [E_28]
[E_91] [91]
Stop button, bottom
JH-B
Release JH-B
[E_92] [92]
Service brake pickup check
MGB
See [E_34]
[E_94] [94]
Stop button, top
JH-T
Release JH-T
[E_9d]
Emergency stop
DH-M
Check DH-M
I-SBC-ERR
Check service brake control unit for error message
[E_9E]
Service brake control error
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
Interlocked
MICONIC F 3/4/5
Q 43831001_00
75
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
[E_9F]
Revision control error
[E_A0] [A0]
PEM/PB: Reset
[E_A1] [A1]
PES/PT: Reset
[E_A2]
PES1/PA: Reset
[E_A3]
PES2/P2: Reset
[E_A4]
PES3/P3: Reset
[E_A5]
MIC F 3/4:
Abbreviation
Note
I-REC-ERR
Correction
Check revision control unit for error message
Check 24 VDC at P01
Remove blocking device
Check parameter setting Replace PEM
See [E_17]
ALCD 80: Reset MIC F 5E: Blocking device, left [E_A6]
KBV-L
MIC F 3/4: PEM: Bus retry reset MIC F 5E: Step chain tension contact, bottom KKS-BL left
[A6]
Interlocked
PB: Bus retry reset
Error Messages Copyright © 2014 INVENTIO AG
Check: Bus connection Jumper setting MICONIC F 3/4/5
Q 43831001_00
76
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_A7]
Error Message
Abbreviation
Correction
MIC F 3/4: PES: Bus retry reset MIC F 5E: Step chain link contact, left
Note
Check parameter setting Replace PES
Check: Step chain Lubrication of step chain
KKL-L
[A7]
PB: Bus retry reset
See [A6]
[E_A8]
MIC F 3/4:
Check parameter setting Replace PES1
See [E_A7]
Check parameter setting Replace PES2
Check P0049
PES1: Bus retry reset MIC F 5E: Step chain link contact, right [E_A9]
KKL-R
MIC F 3/4: PES2: Bus retry reset MIC F 5E: Communication error
RS232/ RS485-2
[E_AA]
PES3: Bus retry reset
Check parameter setting Replace PES3
[E_Ab]
ALCD 80: Bus retry reset
Check parameter setting Replace ALCD 80
[E_AC]
Buffer full reset
Check parameter setting Replace PEM
[AC]
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Q 43831001_00
77
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
Correction
Buffer full reset
Check parameter setting Replace PES
[E_AE]
Buffer full reset
Check parameter setting Replace PES1
[E_AF]
Buffer full reset
Check parameter setting Replace PES2
[E_b0]
MIC F 3/4:
See [E_AA]
Check next error entry and correct
See [E_Ab]
Check next error entry and correct
See [E_AC]
Check next error entry and correct
Update software
[E_Ad] [Ad]
Buffer full reset MIC F 5E: Reset [E_b1]
MIC F 3/4: Buffer full reset MIC F 5E: Reset
[E_b2]
MIC F 3/4: Wrong message reset MIC F 5E: Reset
[b2]
Wrong message reset
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Q 43831001_00
78
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_b3]
Error Message
Abbreviation
MIC F 3/4: Wrong message reset MIC F 5E: Reset
[b3]
Wrong message reset
[E_b4]
MIC F 3/4: Wrong message reset MIC F 5E: Reset
Note
Correction
See [E_Ad]
Check next error entry and correct
Update software
See [E_AE]
Check next error entry and correct
[E_b5]
Wrong message reset
See [E_AF]
[E_b6]
Wrong message reset
See [E_AA]
[E_b7]
Wrong message reset
See [E_Ab]
[E_b8]
MIC F 3/4:
See [E_AC]
Check connecting line
See [E_A0]
Reset MIC F 5E: Bus retry reset [b8]
Reset
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Q 43831001_00
79
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_b9]
Error Message
Abbreviation
MIC F 3/4: Reset MIC F 5E: Buffer full reset
Note
Correction
Check parameter setting Replace PES, PEM
Check of quickly activated inputs
[b9]
Reset
See [E_A0]
[E_bA]
MIC F 3/4:
Check parameter setting Replace PES1, PEM
Reset MIC F 5E:
Check: Connecting line Incorrect devices connected
Wrong message reset [E_bb]
MIC F 3/4: Reset MIC F 5E: Timeout reset
[E_bC]
MIC F 3/4: Reset MIC F 5E: Flash reset
[E_bd]
Reset
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Check parameter setting Replace PES2, PEM
Check connecting line
Check parameter setting Replace PES3, PEM
Set parameter to default Program parameter according to control cabinet sticker
Check parameter setting Replace ALCD 80, PEM Q 43831001_00
80
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_bE] [bE] [E_bF]
Error Message
Abbreviation
Timeout reset Timeout reset
Note
Correction
See [E_AC]
Check jumper setting
See [E_Ad]
Check jumper setting
[E_C0]
Timeout reset
See [E_A8]
[E_C1]
Timeout reset
See [E_A9]
[E_C2]
Timeout reset
See [E_AA]
[E_C3]
Timeout reset
See [E_Ab]
Reset
Press the reset button on the PEM/PB
Reset
Press the reset button on the PES/PT
[E_C6]
Reset
Press the reset button on the PES1
[E_C7]
Reset
Press the reset button on the PES2
[E_C8]
Reset
Press the reset button on the PES3
[E_C9]
Reset
Turn supply voltage at the ALCD 80 off and on
Press the reset button on the PEM, PES
Press the reset button on the PB, PT
[bF]
[E_C4] [C4] [E_C5] [C5]
[E_CA] [CA]
Board reset
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Q 43831001_00
81
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
Note
[E_Cb] [Cb]
Voltage reset
[E_CC]
MIC F 3:
[CC]
Combplate contact 2, bottom left
KKP-BL
MIC F 3 ≥ V3.3: Interlocked
MIC F 4/5:
INBMG INMH INMH-R
Interlocked
30 % motor overspeed [E_Cd]
Check: 22 VAC supply 24 VDC at P01
MIC F 3: Power failure > 250 ms with UPS
USV
Combplate contact 2, bottom right KKP-BR
MIC F 3 ≥ V3.3: Interlocked
MIC F 4: Power failure > 250 ms with UPS [E_CE]
MIC F 3:
[CE]
Combplate contact 2, top left
USV KKP-TL
MIC F 3 ≥ V3.3: Interlocked
INVK-T INVK-B
Interlocked
MIC F 4/5: 30 % overspeed
Error Messages Copyright © 2014 INVENTIO AG
Correction
MICONIC F 3/4/5
See [E_10]
Release the safety brake (if installed) See [E_18]
Check line voltage supply
See [E_10]
Check line voltage supply
See [E_10]
Release safety brake (if installed) See [E_26]
Q 43831001_00
82
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
[E_CF]
MIC F 3:
[CF]
Combplate contact 2, top right
Abbreviation
Note MIC F 3 ≥ V3.3:
Correction
See [E_10]
Release safety brake (if installed) See [E_26]
KBFM-B
See [E_1A]
Skirt contact, middle
KSL-M
See [E_12]
[E_d3] [d3]
Phase failure
RKPH
Measure all three phases to ground Check direction of rotation of main line
[E_d4]
Rubber belt contact, top
KGB-T
[E_d5]
Rubber belt contact, bottom
KGB-B
Check rubber belt
[E_d6]
Blocking device
KBV
Check blocking device
[E_d7]
Combplate heating, top
RTHFK-T ITH-T
See [E_1E]
[E_d8] [d8]
Step upthrust contact, bottom
KUS-B
See [E_1d]
[E_d9]
Brake lining monitor
INBB
Check brake lining Replace brake lining if minimum is reached
[E_dA] [dA]
Stop button, customer provided
RHBS DH-BS
Check RHBS, DH-BS
KKP-TR
Interlocked
30 % overspeed
INVK-T INVK-B
Interlocked
[E_d1]
Smoke detector, bottom
[E_d2]
MIC F 4/5:
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Q 43831001_00
83
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
[E_db]
Water level monitor, bottom
KWS KWS-B
[E_dC]
Contactor pickup check
SK
[E_dE]
PTC resistor, bottom
WTHM-B
[E_dF]
Shutdown with lubrication failure
KDZS KDS
[E_E0]
Unit-specific error, bottom
KSPEZ-B
[E_E1]
Unit-specific error, top
KSPEZ-T
[E_E2]
Unit-specific error
KSPEZ-1
[E_E3]
Unit-specific error
KSPEZ-2
[E_E4]
MIC F 3:
Note
MIC F 3 ≥ V3.2 US version: Interlocked
MIC F 4/5E: MIC F 3:
Check wiring of the SKU, SKD, SRE contactors
Check motor temperature
Unit-specific
See [E_E0]
Unit-specific error MIC F 4/5E:
See [E_E0]
Drive station too warm Cool drive station
Over temperature Error Messages
Check tension station pit for water
Tension station too warm Cool tension station
Over temperature
Copyright © 2014 INVENTIO AG
Check lubrication system: Level switch Manometric switch Tubes for kinks
Unit-specific error
[E_E5]
Correction
MICONIC F 3/4/5
Q 43831001_00
84
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_E6]
Error Message
Abbreviation
Note
MIC F 3:
Unit-specific error MIC F 4/5E: MIC F 3:
[E7]
Unit-specific error MIC F 4/5E: Missing step/pallet, bottom
[E_E8]
See [E_E0]
Machine room too warm Cool machine room
Over temperature [E_E7]
Correction
INVK-B
Interlocked
See [E_E0]
See [E_39]
See [E_E0]
MIC F 3: Brake monitor, channel 1
SKUE1
MIC F 4: Unit-specific error MIC F 5E:
Check: GFU parameters GFU activation
Controlled brake monitor
Error Messages Copyright © 2014 INVENTIO AG
MICONIC F 3/4/5
Q 43831001_00
85
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_E9]
Error Message
Abbreviation
Note
Correction
MIC F 3: Brake monitor, channel 2
SKUE2
MIC F 4:
See [E_E0]
See [E_E8]
See [E_38]
Start the next unit in line
See [E_E0]
See [E_26]
Unit-specific error MIC F 5E: Controlled brake 2 monitor [E_EA]
MIC F 3:
[EA]
Braking distance exceeded MIC F 4/5:
INBMG
Braking distance exceeded
INMH-R
[E_Eb]
Consecutive operation
[E_EC]
MIC F 3:
[EC]
Unit-specific error
MIC F 5: Interlocked
MIC F 4/5: Initiator defective, top
Error Messages Copyright © 2014 INVENTIO AG
INVK-T
MICONIC F 3/4/5
Q 43831001_00
86
5 5.4
Error Messages MICONIC F 3/4/5
Display [E_Ed]
Error Message
Abbreviation
Note
Correction
MIC F 3/4: Unit-specific error MIC F 5E: Emergency stop 2
[E_EE] [E_EF]
DH
See [E_E0]
Press DRES2 or DRES3 to show the error
See [E_39]
See [E_26]
Unit-specific error
[E_Er]
Electronically interlocked error
[E_F0] [F0]
Missing step/pallet, top
INVK-T
[E_F1] [F1]
Initiator defective, bottom
INVK-B
[E_F2] [F2]
PES/PT: System check
MIC F 5E: Interlocked
See [E_A7]
[E_F3] [F3]
PEM/PB: System check
MIC F 5E: Interlocked
See [E_A6]
[E_F4] [F4]
PES/PT-PB: System check
See [E_A7]
[E_F5] [F5]
PEM/PB-PT: System check
See [E_A6]
Error Messages Copyright © 2014 INVENTIO AG
Interlocked
MICONIC F 3/4/5
Q 43831001_00
87
5 5.4
Error Messages MICONIC F 3/4/5
Display
Error Message
Abbreviation
[E_F6] [F6]
RB contactor dropout check
RB
[E_F7] [F7]
RGBA contactor dropout check
RGBA
Error Messages Copyright © 2014 INVENTIO AG
Note
MIC F 5: Interlocked
MICONIC F 3/4/5
Correction
Check RB
Check RGBA, RGBA1
Q 43831001_00
88