Customer Item number Service Flowserve reference Date

: : : : :

WIJAYA KARYA, PT. P 7A/B/C LPG FILLING PUMP 445564384 October 1, 2015

Pump size & type Based on curve no. Number of stages

: 4HPX13A : 4HPX13A-1-2 : 1

Capacity Head Specific gravity Pump speed Test tolerance

: : : : :

167.0 m3/h 91.18 m 0.510 2975 rpm API 610 11th Edition

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND POWER.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

1 of 20

Hydraulic Datasheet Customer Customer reference Item number Service

: : : :

WIJAYA KARYA, PT. PT WIKA P 7A/B/C LPG FILLING PUMP

Operating Conditions Capacity : 167.0 m³/h Water capacity (CQ=1.00) : Normal capacity : Total developed head : 91.18 m Water head (CH=1.00) : NPSH available (NPSHa) : 15.1 m NPSHa less NPSH margin : 14.1 m Maximum suction pressure : 18.0 kg/cm²g Liquid : Hydrocarbon : 35 °C / 0.510 : / 14.0 mm : 0.12 cP / 136.59 psia

Liquid type Temperature / Spec. Gravity Solid Size - Actual / Limit Viscosity / Vapor pressure Hydraulic power Pump speed Pump overall efficiency (CE=1.00)

: 21.1 kW : 2975 rpm : 69.4 %

NPSH required (NPSH3) Rated power Maximum power Driver power Casing working pressure (based on shut off @ cut dia/rated SG) Maximum allowable Hydrostatic test pressure Est. rated seal chamb. press.

: : : : :

4.3 m 30.4 kW 38.0 kW 37.0 kW / 49.6 hp 23.2 kg/cm²g

: 42.2 kg/cm²g : 63.3 kg/cm²g : 0.9 kg/cm²g

Pump / Stages Based on curve no. Flowserve reference Date

: : : :

4HPX13A 4HPX13A-1-2 445564384 October 1, 2015

Material column code Pump specification

Materials / Specification : S-8 : -

/1

Other Requirements Hydraulic selection : API 610 11th Edition Construction : API 610 11th Edition Test tolerance : API 610 11th Edition Max NSS : 11000.0 (US units) Min NPSHa Margin : 1.0 m Driver Sizing : API 610 Performance data based on standard impeller Seal configuration : Single Seal

Performance Impeller diameter Rated Maximum Minimum Suction specific speed Minimum continuous flow Maximum head @ rated dia Flow at BEP Flow as % of BEP Efficiency at normal flow Impeller dia ratio (rated/max) Head rise to shut off Total head ratio (rated/max)

: : : : : : : : : : : :

266.9 mm 323.8 mm 254.0 mm 9370 (US units) 76.7 m³/h 102.24 m 197.1 m³/h 84.7 % 82.4 % 12.1 % 64.5 %

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND POWER.

** denotes rejection criteria

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

2 of 20

Full Page GA Drawing

All dimensions are in millimeters unless otherwise specified Customer Item number

: WIJAYA KARYA, PT. : P 7A/B/C

Pump size & type Pump speed / Stages

: 4HPX13A : 2975 rpm / 1

Service Customer PO # Flowserve reference

: LPG FILLING PUMP : : 445564384

Flow / Head Driver power / Frame Volts / Phase / Hz

: 167.0 m3/h / 91.18 m : 37.0 kW / 49.6 hp / 200L : - / - / 50

Copyright © 2014 Flowserve. All rights reserved.

Drawing number Date Certified by / Date :

: : October 1, 2015 : -

Seal type Seal flush plan

: : Plan 11 Affinity v1.3.9.1

4 of 20

Customer Item number Service Flowserve reference Date

: : : : :

WIJAYA KARYA, PT. P-30 DEP WELL PUMP 445564384 October 2, 2015

Pump size & type Based on curve no. Number of stages

: 2K2x1.5V-10ARV M3V : MIII8021AV : 1

Capacity Head Specific gravity Pump speed Test tolerance

: : : : :

20.0 m3/h 49.41 m 1.000 2900 rpm Hydraulic Institute Level B

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

5 of 20

Hydraulic Datasheet Customer Customer reference Item number Service

: : : :

WIJAYA KARYA, PT. PT WIKA P-30 DEP WELL PUMP

Operating Conditions Capacity : 20.0 m³/h Water capacity (CQ=1.00) : Normal capacity : Total developed head : 49.41 m Water head (CH=1.00) : NPSH available (NPSHa) : Ample NPSHa less NPSH margin : Maximum suction pressure : 0.0 kg/cm²g Liquid : Other : 55 °C : : 1.00 cP

Liquid type Temperature / Spec. Gravity Solid Size - Actual / Limit Viscosity / Vapor pressure

Pump / Stages Based on curve no. Flowserve reference Date Material column code Pump specification

: : : :

2K2x1.5V-10ARV M3V MIII8021AV 445564384 October 2, 2015

/1

Materials / Specification : DS : ANSI B73.2M

Other Requirements Hydraulic selection : No specification Construction : No specification Test tolerance : Hydraulic Institute Level B Driver Sizing : API 610 Seal configuration : Single Seal

/ 1.000 //-

Hydraulic power Pump speed Pump overall efficiency (CE=1.00)

: 2.69 kW : 2900 rpm : 42.1 %

NPSH required (NPSH3) Rated power Maximum power Driver power Casing working pressure (based on shut off @ cut dia/rated SG) Maximum allowable Hydrostatic test pressure Est. rated seal chamb. press.

: : : : :

1.7 m 6.39 kW 7.44 kW 11.2 kW / 15.0 hp 5.9 kg/cm²g

: 19.5 kg/cm²g : 30.1 kg/cm²g : -

Performance Impeller diameter Rated Maximum Minimum Suction specific speed Minimum continuous flow Maximum head @ rated dia Flow at BEP Flow as % of BEP Efficiency at normal flow Impeller dia ratio (rated/max) Head rise to shut off Total head ratio (rated/max)

: : : : : : : : : : : :

201.6 mm 254.0 mm 152.4 mm 5660 (US units) 2.4 m³/h 59.08 m 21.2 m³/h 94.3 % 79.4 % 19.6 % 55.2 %

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

6 of 20

Full Page GA Drawing

All dimensions are in millimeters unless otherwise specified Customer Item number

: WIJAYA KARYA, PT. : P-30

Pump size & type Pump speed / Stages

: 2K2x1.5V-10ARV M3V : 2900 rpm / 1

Service Customer PO # Flowserve reference

: DEP WELL PUMP : : 445564384

Flow / Head Driver power / Frame Volts / Phase / Hz

: 20.0 m3/h / 49.41 m : 11.2 kW / 15.0 hp / 254TC : 400 / 3 / 50

Copyright © 2014 Flowserve. All rights reserved.

Drawing number Date Certified by / Date :

: : October 2, 2015 : -

Seal type Seal flush plan

: ISC2 Pusher : F - API Plan 13 Affinity v1.3.9.1

8 of 20

Customer Item number Service Flowserve reference Date

: : : : :

WIJAYA KARYA, PT. P-29 WATER PIT PUMP 445564384 October 2, 2015

Pump size & type Based on curve no. Number of stages

: 1K3x1.5V-81RV M3V : MIII7168 : 1

Capacity Head Specific gravity Pump speed Test tolerance

: : : : :

30.0 m3/h 42.45 m 1.000 2900 rpm Hydraulic Institute Level B

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

9 of 20

Hydraulic Datasheet Customer Customer reference Item number Service

: : : :

WIJAYA KARYA, PT. PT WIKA P-29 WATER PIT PUMP

Operating Conditions Capacity : 30.0 m³/h Water capacity (CQ=1.00) : Normal capacity : Total developed head : 42.45 m Water head (CH=1.00) : NPSH available (NPSHa) : Ample NPSHa less NPSH margin : Maximum suction pressure : 0.0 kg/cm²g Liquid : Other : 55 °C : : 1.00 cP

Liquid type Temperature / Spec. Gravity Solid Size - Actual / Limit Viscosity / Vapor pressure

Pump / Stages Based on curve no. Flowserve reference Date Material column code Pump specification

: : : :

1K3x1.5V-81RV M3V MIII7168 445564384 October 2, 2015

/1

Materials / Specification : DS : ANSI B73.2M

Other Requirements Hydraulic selection : No specification Construction : No specification Test tolerance : Hydraulic Institute Level B Driver Sizing : API 610 Seal configuration : Single Seal

/ 1.000 //-

Hydraulic power Pump speed Pump overall efficiency (CE=1.00)

: 3.46 kW : 2900 rpm : 57.2 %

NPSH required (NPSH3) Rated power Maximum power Driver power Casing working pressure (based on shut off @ cut dia/rated SG) Maximum allowable Hydrostatic test pressure Est. rated seal chamb. press.

: : : : :

1.8 m 6.05 kW 7.72 kW 11.2 kW / 15.0 hp 4.6 kg/cm²g

: 19.5 kg/cm²g : 30.1 kg/cm²g : -

Performance Impeller diameter Rated Maximum Minimum Suction specific speed Minimum continuous flow Maximum head @ rated dia Flow at BEP Flow as % of BEP Efficiency at normal flow Impeller dia ratio (rated/max) Head rise to shut off Total head ratio (rated/max)

: : : : : : : : : : : :

188.9 mm 204.8 mm 101.6 mm 7680 (US units) 3.9 m³/h 45.75 m 37.9 m³/h 79.1 % 92.2 % 7.8 % 80.7 %

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

10 of 20

Full Page GA Drawing

All dimensions are in millimeters unless otherwise specified Customer Item number

: WIJAYA KARYA, PT. : P-29

Pump size & type Pump speed / Stages

: 1K3x1.5V-81RV M3V : 2900 rpm / 1

Service Customer PO # Flowserve reference

: WATER PIT PUMP : : 445564384

Flow / Head Driver power / Frame Volts / Phase / Hz

: 30.0 m3/h / 42.45 m : 11.2 kW / 15.0 hp / 254TC : 400 / 3 / 50

Copyright © 2014 Flowserve. All rights reserved.

Drawing number Date Certified by / Date :

: : October 2, 2015 : -

Seal type Seal flush plan

: ISC2 Pusher : F - API Plan 13 Affinity v1.3.9.1

12 of 20

Customer Item number Service Flowserve reference Date

: : : : :

WIJAYA KARYA, PT. P-28 A/B SEA WATER INTAKE P... 445564384 October 2, 2015

Pump size & type Based on curve no. Number of stages

: 12EHM : EC-2657 : 2

Capacity Head Specific gravity Pump speed Test tolerance

: : : : :

570.0 m3/h 76.68 m 1.000 2950 rpm Hydraulic Institute Level A

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Bowl performance shown below is corrected for materials, viscosity and construction.

Bowl head of 77.81 m corresponds with 76.68 m head at discharge flange adjusted for elevation and friction losses.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

13 of 20

Hydraulic Datasheet Customer Customer reference Item number Service

: : : :

WIJAYA KARYA, PT. PT WIKA P-28 A/B SEA WATER INTAKE PUMP

Pump / Stages Based on curve no. Flowserve reference Date

Operating Conditions Capacity Water capacity (CQ=1.00) Normal capacity Total developed head Water head (CH=1.00) NPSH available (NPSHa) NPSHa less NPSH margin Maximum suction pressure Rated suction pressure

: : : : : : : : :

: : : :

12EHM EC-2657 445564384 October 2, 2015

/2

Materials / Specification

570.0 m³/h 76.68 m Ample Not applicable Not applicable

Material column code

: B30 Other Requirements

Hydraulic selection : No specification Construction : No specification Test tolerance : Hydraulic Institute Level A Driver Sizing : API 610

Liquid Liquid type Liquid description Temperature / Spec. Gravity Viscosity / Vapor pressure

: : : :

Other WATER 55 °C 1.00 cP

Pump speed NPSH required (NPSH3) Minimum submergence Hydraulic power Pump overall efficiency (CE=1.00) Power: (Rated / Max) Driver power Bowl Pressure (based on shut off @ cut dia/rated SG) Maximum allowable Bowl & column hydrotest Dischg Head Dischg Region MAWP Suction specific speed

: : : : : : : :

2950 rpm 13.2 m 609.6 mm 120 kW 77.6 % 155 kW / 155 kW 185 kW / 248 hp 13.3 kg/cm²g

: : : :

30.2 kg/cm²g 16.6 kg/cm²g 20.0 kg/cm²g 9240 (US units)

/ 1.000 / Performance Impeller diameter

: Rated / Maximum / Minimum : 229.1 mm 237.0 mm 214.4 mm Impeller dia ratio (rated/max) : 96.7 % Maximum head @ rated dia : 133.20 m Head rise to shut off : 71.2 % Total head ratio (rated/max) : 82.7 % Flow at BEP : 492.7 m³/h Flow as % of BEP : 115.7 % Minimum continuous flow : 198.0 m³/h Rated thrust (at Rated flow) : 8800.6 N Maximum thrust (at Shut off flow) : 14846.7 N Min thrust - Runout flow / Max Suction : 6474.1 N (A negative thrust value indicates an upthrust condition)

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY. Bowl performance shown below is corrected for materials, viscosity and construction.

Bowl head of 77.81 m corresponds with 76.68 m head at discharge flange adjusted for elevation and friction losses.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

14 of 20

Full Page GA Drawing

All dimensions are in millimeters unless otherwise specified Customer Item number

: WIJAYA KARYA, PT. : P-28 A/B

Pump size & type Pump speed / Stages

: 12EHM : 2950 rpm / 2

Service Customer PO # Flowserve reference

: SEA WATER INTAKE PUMP : : 445564384

Flow / Head Driver power / Frame Volts / Phase / Hz

: 570.0 m3/h / 76.68 m : 185 kW / 248 hp / : 400 / 0 / 50

Copyright © 2014 Flowserve. All rights reserved.

Drawing number Date Certified by / Date :

: : October 2, 2015 : -

Seal type Seal flush plan

: Packing : Plan 13 Affinity v1.3.9.1

16 of 20

Customer Item number Service Flowserve reference Date

: : : : :

WIJAYA KARYA, PT. P-26 JOCKEY PUMP 445564384 October 2, 2015

Pump size & type Based on curve no. Number of stages

: 2K3x1.5LF-13 M3 LF : MIII7306V : 1

Capacity Head Specific gravity Pump speed Test tolerance

: : : : :

12.0 m3/h 106.52 m 1.000 2900 rpm Hydraulic Institute Level B

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY. MCSF PROVIDES MECHANICAL PROTECTION ONLY. MINIMUM THERMAL FLOW MUST BE CALCULATED FOR THE SPECIFIC FLUID AND OPERATING CONDITIONS.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

17 of 20

Hydraulic Datasheet Customer Customer reference Item number Service

: : : :

WIJAYA KARYA, PT. PT WIKA P-26 JOCKEY PUMP

Operating Conditions Capacity : 12.0 m³/h Water capacity (CQ=1.00) : Normal capacity : Total developed head : 106.52 m Water head (CH=1.00) : NPSH available (NPSHa) : 7.9 m NPSHa less NPSH margin : Maximum suction pressure : 0.0 kg/cm²g Liquid type Temperature / Spec. Gravity Solid Size - Actual / Limit Viscosity / Vapor pressure

Pump / Stages Based on curve no. Flowserve reference Date

: : : :

2K3x1.5LF-13 M3 LF MIII7306V 445564384 October 2, 2015

Material column code Pump specification

Materials / Specification : DCI : ANSI B73.1

/1

Other Requirements Hydraulic selection : No specification Construction : No specification Test tolerance : Hydraulic Institute Level B Driver Sizing : API 610 Seal configuration : Single Seal

Liquid : Hydrocarbon : 35 °C / 1.000 : / 8.0 mm : 0.78 cP / 0.57 psia

Hydraulic power Pump speed Pump overall efficiency (CE=1.00)

: 3.48 kW : 2900 rpm : 21.6 %

NPSH required (NPSH3) Rated power Maximum power Driver power Casing working pressure (based on shut off @ cut dia/rated SG) Maximum allowable Hydrostatic test pressure Est. rated seal chamb. press.

: : : : :

0.9 m 16.1 kW 23.0 kW 22.4 kW / 30.0 hp 10.8 kg/cm²g

: 17.6 kg/cm²g : 26.4 kg/cm²g : -

Performance Impeller diameter Rated Maximum Minimum Suction specific speed Minimum continuous flow Maximum head @ rated dia Flow at BEP Flow as % of BEP Efficiency at normal flow Impeller dia ratio (rated/max) Head rise to shut off Total head ratio (rated/max)

: : : : : : : : : : : :

247.6 mm 330.2 mm 228.6 mm 7890 (US units) 0.0 m³/h 108.47 m 29.7 m³/h 40.4 % 75.0 % 1.8 % 53.3 %

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY. MCSF PROVIDES MECHANICAL PROTECTION ONLY. MINIMUM THERMAL FLOW MUST BE CALCULATED FOR THE SPECIFIC FLUID AND OPERATING CONDITIONS.

Copyright © 2014 Flowserve. All rights reserved.

Affinity v1.3.9.1

18 of 20

Full Page GA Drawing

All dimensions are in millimeters unless otherwise specified Customer Item number

: WIJAYA KARYA, PT. : P-26

Pump size & type Pump speed / Stages

: 2K3x1.5LF-13 M3 LF : 2900 rpm / 1

Service Customer PO # Flowserve reference

: JOCKEY PUMP : : 445564384

Flow / Head Driver power / Frame Volts / Phase / Hz

: 12.0 m3/h / 106.52 m : 22.4 kW / 30.0 hp / 286TS : - / 3 / 50

Copyright © 2014 Flowserve. All rights reserved.

Drawing number Date Certified by / Date :

: : October 2, 2015 : -

Seal type Seal flush plan

: ISC2 Pusher : D - Plan 11 Affinity v1.3.9.1

20 of 20