Roofing Chapter 6
ROOFS ARE CONSTRUCTED WITH THE PRIMARY FUNCTION OF PROVIDING THE BUILDING OCCUPANTS PROTECTION
Galvanized Iron Sheet --G.I. SHEET IS EITHER: • PLAIN • CORRUGATED
G.I. SHEET is either: • PLAIN G.I. SHEET IS WIDELY USED FOR ROOFING, GUTTER, FLASHING, DOWN SPOUT, RIDGE, HIP ROLL AND MANY OTHER TINSMITHING WORK. STANDARD COMMERCIAL SIZE: 90cm x 240cm / 36” x 8’ • CORRUGATED G.I. SHEET IS COMMONLY USED FOR ROOFING AND SIDING MATERIALS. STANDARD COMMERCIAL SIZE: 80cm x 1.5m to 3.6m / 32” x 5’to 12’
32 ’
5’ – 12’
LENGTH IN METERS AND FEET
STANDARD WEIGTH OF GALVANIZED IRON SHEET GAUGE THICK 1.5 M. 1.8 M. 2.1 M. 2.4 M. 2.7 M. 3.0 M. 3.60 M. NO. CM. IN KILOGRAMS 5 FT. 6 FT. 7 FT 8 FT. 9 FT. 10 FT. 12 FT. 14 GAUGE .203 THICK CM. 15NO. .180 16 14 17 15 16 18 17 19 18 20 19 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 29 28 30 29 30
.163 .203 .180 .147 .163 .132 .147 .117 .132 .117 .102 .102 .094 .094 .086 .086 .079 .079 .071 .071 .064 .064 .056 .056 .051 .048 .051 .043 .048 .041 .043
22.36 1.5 M. 20.25 5 FT. 18.44 22.36 20.25 16.43 18.44 14.73 16.43 13.03 14.73 13.03 11.32 11.32 10.43 10.43 9.62 9.62 8.73 8.73 7.91 7.91 7.03 7.03 6.19 6.19 5.76 5.33 5.76 4.90 5.33 4.48 4.90
FEET 44.72 26.83 LENGTH 31.30 IN METERS 35.78 AND 40.25 53.66 1.8 M. 2.1 M. 2.4 M. 2.7 M. 3.0 M. 3.60 M. 24.30 28.35 32.40 36.45 40.50 48.60 6 FT. 7 FT 8 FT. 9 FT. 10 FT. 12 FT. 27.76 25.39 35.78 29.02 40.25 32.64 44.72 36.27 53.66 43.52 26.83 31.30 24.30 28.35 19.72 23.00 32.40 26.29 36.45 29.58 40.50 32.86 48.60 39.43 27.76 25.39 29.02 32.64 36.27 43.52 17.67 20.62 23.56 26.51 29.45 35.34 19.72 23.00 26.29 29.58 32.86 39.43 15.63 18.24 23.56 20.84 26.51 23.45 29.45 26.05 35.34 31.27 17.67 20.62 15.63 18.24 13.58 15.85 20.84 18.11 23.45 20.38 26.05 22.64 31.27 27.17 13.58 15.85 18.11 20.38 22.64 27.17 12.52 14.60 16.69 18.78 20.86 25.03 12.52 14.60 16.69 18.78 20.86 25.03 11.54 13.46 15.38 15.38 17.31 17.31 19.23 19.23 23.08 23.08 11.54 13.46 10.47 12.22 10.47 12.22 13.96 13.96 15.71 15.71 17.45 17.45 20.94 20.94 9.49 11.07 9.49 11.07 12.66 12.66 14.24 14.24 15.82 15.82 18.29 18.29 8.43 9.84 11.24 12.65 14.05 16.86 8.43 9.84 11.24 11.14 12.65 12.38 14.05 14.86 16.86 7.43 8.66 9.90 7.43 8.66 9.90 10.37 11.14 11.52 12.38 13.82 14.86 6.91 8.06 9.22 6.39 7.46 8.52 9.59 6.91 8.06 9.22 10.37 10.65 11.52 12.78 13.82 5.88 6.86 7.84 8.82 9.80 11.76 6.39 7.46 8.52 9.59 10.65 12.78 5.37 6.27 7.16 8.06 8.95 10.74 5.88 6.86 7.84 8.82 9.80 11.76
THE THICKNESS OF GALVANIZED IRON SHEET IS .041 4.48 7.16 NUMBER 8.06 8.95 14 TO 10.74 MEASURED IN5.37 TERMS6.27 OF GAUGE FROM
BEFORE MAKING AN ESTIMATE OF CORRUGATED G.I. ROOFING SHEETS, THE FOLLOWING IMPORTANT DATA SHOULD BE CONSIDERED FIRST. 1.Verify the specifications for a.) Side Lapping 1- ½ corrugation use 0.70m 2 ½ corrugations use 0.60m b.) End Lapping 2. The length of G.I. sheet is proportionally Standard joint; use adjusted by the spacing of purlins from 25-30 cm (refer to table 6-2) ex. In 1.5 m (5’) the spacing of purlins i 0.60 m. 3.
A good roofing design are those that
LENGTH FEET-METER
EFFECTIVE WIDTH COVERING SIDE LAPPING
PURLINS SPACING CM.
NUMBER OF NAILS OR RIVETS PER SHEET
1–½
2–½
6” – 1.80
.70
.60
.75
.14
7” – 2.10
.70
.60
.60
.18
8” – 2.40
.70
.60
.70
.18
9” – 2.70
.70
.60
.60
.22
10” – 3.00
.70
.60
.67
.22
12” – 3.60
.70
.60
.66
.26
EFFECTIVE COVERING OF G.I. ROOFING SHEETS PURLINS SPACING AND NUMBER OF FASTENERS PER SHEET
Procedures in Estimating G.I. Roof Sheet and its Accessories
Procedures in Estimating G.I. Roof Sheet and its Accessories
•1.Determine the number of sheets per row:
2. Determine the combination of roofing sheets:
3. Find the number of order by the result in Step 1 of Step 2
MATERIALS
NUMBER OF PIECES PER KILOGRAM
1. Find the number of rivets or nails for total sheet Take note:
G.I. ROOF NAILS
120
G.I. RIVETS
180
G.I. WASHERS
126
LEAD WASHERS
75
QUANTITY OF ROOF ACCESSORIES IN KILOGRAMS UMBRELLA NAILS 120
2.
3
SIZE OF PURLINS INCHES
SIZE OF G.I. STRAP INCHES
NUMBER OF STRAP IN ONE PLAIN SHEET
2” X 3”
1” X 9”
384
2” X 4”
1” X 10”
342
2” X 5”
1” X 11”
312
To convert to kilogram refer to table 6-
1” X 12” 288 3. Solve the no. of plain G.I. sheets 2” X 6” SIZE AND QUANTITY OF STRAPS IN ONE PLAIN G.I. SHEET required for anchor strap with the aid of table 6-4
SOLUTION A. Corrugated G.I. Sheet 1.Divide the length of the gutter by the effective covering of one sheet. Refer to Table6-2 under 1 ½ corrugation the value is .70. Divide: 14.00 m. = 20 sheets in one row 70 2.The length of the rafter is 6.00 meters. Thus, a combination of 3.60 m. and 2.70 m. long G.I. Sheet or 12 ft. x 9 ft. Order : 20 pcs. 32” x 12’ corrugated G.I. sheet and 20 pcs. 32” x 9’ corrugated G.I. sheet B. Rivets 3.Refer to Table 6-2. For a 12 ft. and 9 ft. long roof sheet, Multiply: For 12 ft. long : 20 x 26 = 520 pieces For 9 ft. long : 20 x 22 = 440 Total rivets …………. 960 pieces 2.Convert to kilograms. Refer to Table 6-3, Divide : 9.60 pieces = 5.3 say 5.5 kilograms 180
C. G.I. Washers 1.Double the number of rivets; 960 x 2 = 1,920 pcs. 2.Convert to kilograms. Refer to Table 6-3 for G.I. washers SUMMARY Divide: 1,920 = 15.24 say 15.5 kilograms 126
20 pcs. 32” x 12 ft. corr D. Plain G.I. Strap on 2” x 3” Purlins sheet 20 pcs. 32” x 9 3.Total number of rivets = 960 pieces 5.5 kg. G.I. rive 2. Refer to Table 6-4. Using a 2” x 3” purlins, 15.5 kg. G.I. was Divide: 960 = 2.5 pieces plain G.I. sheet 13.0 kg. lead was 384 2.5 pcs. plain G.I. s E. Lead Washers 4.The number of rivets is the number of lead washer = 960 2. Refer to Table 6-3 For lead washers; Divide : 960 = 12.8 say 13 kilograms 75
SOLUTION A. Corrugated G.I. Sheets Determine the number of roof sheet. Refer to Table 6-2, Using 2 ½ corrugations; Divide: 18.00 m = 30 pcs. .60 The length of the rafter is 6.00 meters or a combination of 3.60 and 2.70 meters. (12’ and 9’) roof sheet (see Table 6-5) multiply each sheet length by the result of step -1. 30 pcs. 32” x 12 ft. and 30 pcs. 32” x 9 ft. G.I. roof sheets. Take note that this is only one side of the roof. For two sides, double the quantity. 2 x 30 = 60 pcs x 32 x 12 ft
B. Umbrella Nails Determine the number of umbrella nails for the 12 ft. and 9 ft. roof sheets. Refer to Table 6-2; Multiply : 60 pcs. of 1 ft. x 26 = 1,560 pieces 60 pcs. of 9 ft. x 22 = 1,320 pieces Total……...2,880 pieces Convert to kilograms. Refer to Table 6-3; Divide: 2,880 = 24 kilograms of umbrella nail 120
A. Corrugated G.I. Sheet 1.Determine the number of roof sheet. Refer to Table 6-2; Divide : 12.90 m. = 21.5 say 22 pcs. .60 2.Determine the length of the rafter = 4.80 m. or 16ft. Refer to Table 6-5. For 16 ft. it requires a combination of 10 ft. and 7 ft. or 9 ft. and 8 ft. Thus, Order: 22 pcs. of 32” x 10 ft. and 22 pcs. of 32” x 7 ft. roofing sheets 3.Again, take note that this is only for one side of the roof. To include the other side, double the quantity. 2 x 22 = 44 pcs. of 32” x 9’ and 2 x 22 = 44 pcs of 32” x 8’ roof sheets. B. Roof Nails and Lead Washers 4.Solve for the quantity of roof nails. Refer to Table 6-2; For 3.00 m. (10 ft.) sheet: 44 x 22 = 968 pcs. For 2.10 m. (7 ft.) sheet: 44 x 18 = 792 pcs. Total roof nails………………… 1,760 pcs 2.Convert 1,760 pcs. into kilograms. Refer to Table 6-3; Divide: 1,760 = 14.7 say 15 kilos G.I. roof nails 120 1760 = 23.5 say 24 kilos lead washers. 75
SOLUTION A. Roofing Sheets Determine the number of roofing sheet in one row along the 18.00 m. length of the gutter. Refer to Table 6-2 for 2 - ½ side lap corrugation. Divide: 18.00 m. = 30 pcs. .60 Determine the length of the rafter. For a 6.00 meters long, choose a combination of 12 ft. and ft. roof sheet. See Table 6-5, 30 pcs. of 32” x 12 ft. and 30 pcs. of 32” x 9 ft. corrugated G.I. sheet Take note that the above quantity is only for one side of the roof. To include the other side double the quantity. 2 x 30 = 60 pcs. 12 ft. and 2 x 30 = 60 pcs. 9 ft. roofing sheets Considering that the roof is a hipped type, wastage on cutting can not be avoided, hence add 5% allowance if the angle of the hip is 45° and 10° if not 45°. The percentage allowance shall be multiplied to the total number of sheets. Get a longer sheet to avoid excessive waste in cutting. Thus, 60 + 60 = 120 pcs. x 5% = 6 pcs. of 12 ft. Order : 66 pcs. 32” x 12 ft. and 60 pcs. 32” x 9 ft. corrugated G.I. sheets
B. G.I. Rivets Determine the number of rivets. Refer to Table 6-2; Multiply: For 12 ft. sheet: 60 x 26 = 1,560 pcs. For 9 ft. sheet: 60 x 22 = 1,320 pcs. Total number of rivets……2,880 pcs. Convert to kilograms: Refer to Table 6-3; Divide: 2,880 = 16 kilograms 180 C. G.I. and Lead Washers Double the number of rivets = 2880 x 2 = 5,760 pcs. Refer to Table 6-3, Divide: 5760 = 45.7 say 46 kilograms 126 Lead washer is the same number as the rivets. Refer to Table 6-3 Divide: 2,880 pcs. = 38.4 say 39 kilograms 75 D. Plain G.I. Anchor Strap Refer to Table 6-4. The Size of G.I. strap on a 2” x 4” purlins is 1" x 10" . Number of strap is equal to the number of rivets = 2,880. Solve for the number of plain sheet. Refer to Table 6-4. Divide:
Gutter, Flashing, Ridge, Hipped and Valley Roll TINSMITHING WORK
THE PRIMARY CONSIDERATION IN TINSMITHING WORK IS ECONOMY WHICH SIMPLY MEAN: “TO UTILIZE EVERY INCH OF THE TIN SHEET”. Estimating Procedures : 1.Determine the total length of the gutter in meter. 2.Divide this length by 2.35 meter to find the number of gutter required. (2.35 m. is the effective length of one gutter.) 3.Find the total width of one gutter. ( see the detailed plan.) 4.Divide .90 meter (36 inches width of one plain G.I. sheets by the result of step-3 to find out how many gutter could be made out from one plain G.I. sheet. The fractional value or extra cut will be reserved for other smaller parts. 5.Divide the result of step-2 by the result of step-4. the result is the required number of G.I. sheets.
SOLUTION Find the total length of the gutter. Length = 2 (18.00 ) + 2 ( 10.00 ) = 36.00 + 20.00 L = 56.00 meters. Divide the length by 2.35 meters the effective length of one gutter. 56.00 = 23.82 say 24 pcs. 2.35 The total width of the gutter is 52.5 centimeters (see cross section of gutter). Subtract 52.5 from 90 centimeters the standard width of one plain G.I sheet.
This 37.5 centimeters excess cut from one plain G.I. sheet could be set aside momentarily to be considered in making other roof accessories such as flashing, downspout, anchor strap for riveting etc. Thus, only one gutter at 2.40 m (8 ft.) long could be made out from one plain G.I sheet. Therefore, order : 24 pcs. 90 cm. x 240 cm.(36” x 8 ft.) Plain G.I. sheet.
ITEM
EFFECTIVE LENGTH IN METERS
GUTTER
2.35
FLASHING
2.30
RIDGE ROLL
2.20
VALLEY ROLL
2.30
HIPPED ROLL
2.20 ¼ BAR (.25) PER SOLDER JOINT 10 CC PER SOLDERING LEAD
SOLDERING LEAD MORIATIC ACID
ROOF ACCESSORIES COMMERCIAL SIZE
EFFECTIVE WIDTH COVERING CORRUGATION
IN. / FT.
METER
1–½
2–½
26” X 8’
.650 X 2.40
.46 M.
.31 M.
29” X 8’
.725 X 2.40
.53 M.
.38 M.
CORRUGATED PLASTIC ROOF SHEET
SOLUTION A. ) Gutter Find the total length of the roof gutter. From Figure 6-8, the total length is =20 meters. Refer to Table 6-6. Divide this length by the effective length of one gutter. 20 m = 8.5 say 9 pcs. gutter 2.35 Determine the total width of one gutter. From Figure 6-8, the total width is = 45 cm. Divide the width of the plain G.I. sheet by 45 cm. 90 cm.= 2 pcs 45 This simply mean that 2 pcs. gutter could be made out from one plain G.I. sheet. Thus, divide the result of step
9 pcs. = 4.5 say 5 pcs. plain G.I. sheet 2 B.) Flashing Determine the total length of the flashing. From Figure 6-8, Multiply: 4 x 4.50 m. = 18 meters Find the number of flashing. Refer to Table 6-6; Divide : 18 m. = 7.8 say 8 pcs. 2.30 Width of plain G.I. sheet divided by width of flashing 90 cm = 2 pcs. of flashing in one plain G.I. sheet 45 Divide the result of step 2 by step 3. to find the number of plain sheet
C.) Ridge Roll Find the total length of the ridge roll = 10 meters. Refer to Table 6-6, for ridge roll; Divide : 10.00 m. = 4.5 pcs. ridge roll 2.20 Determine how many ridge roll can be made out from one plain G.I sheet. 90 cm. = 2 pcs. 45 cm. Divide step- 1 by step – 2 tofind the number of plain G.I. sheet required. 4.5= 2.25 Order 2 pcs. .90 m x 2.40 m. (36” x 8’) plain G.I. sheet. Get the balance of .25 from the excess cut of gutter.
Summary For Gutter ; 5 pcs. 90 cm. x 240 cm. plain G.I. sheet Flashing ; 4 pcs. 90 cm. x 240 cm. plain G.I. sheet Ridge Roll ; 2 pcs. 90 cm. x 240 cm. plain G.I. sheet Total ; 11 pcs. plain G.I. sheets
Asbestos Roofing DIFFERENT KINDS OF ASBESTOS ROOFING 1. 2. 3. 4. 5. 6.
STANDARD CORRUGATED SHEET 4-V CORRUGATED SHEET KANALETAS PLACA ROMANA TENCOR CORRUGATED SHEET ARDEX LIGHTWEIGHT CORRUGATED SHEET
Estimating Procedures: 1. The number of corrugated asbestos roofing is determined by dividing the gutter length by the effective width covering of one sheet. 2. In finding the number of flashing, gutter, ridge, hip and valley roll, divide the total length by the effective length of the accessories. 3. Other parts such as ridge end cap, apron flashing, gutter corner, down spout and fittings are determine by direct counting. They are already made according to factory standard sizes.
SOLUTION A.) Standard Corrugated Sheet 1.Find the total length of the gutter. 2 x 26.00 m. = 52.00 meters. 2.Refer to Table 6-8. Divide 52.00 meters by the effective width of one sheet : 52.00 m. = 62 pcs. standard asbestos sheet. .838 B.) Gutter 1.The total length of the ridge roll is = 26.00 m. Refer to Table 6-8, divide by the effective length of gutter. 2 x 26.00 m. = 22.26 pcs. 2.336 m. C.) Ridge Roll 1. The total length of the ridge is = 26.00 meters. Refer to Table 6-8 for ridge roll. Divide: 26.00 m. = 31.0 ridge roll .838
D.) Flashing 1.Find the total length of the flashing ( see figure) 3.00 m. x 4 sides = 12 meters 2. Refer to Table 6-8,For outside flashing Divide: 12.00 m = 5.25 say 6 pcs. outside flashing 2.286 E.) Ridge End Cap 1.From Figure 6-9 by actual count, there are 2 pieces ridge end cap. Thus, order 2 pcs.
Summary 62 pcs. 1.20 x 3.00 Standard corrugated sheet 23 pcs. standard gutter 31 pcs. standard ridge roll 6 pcs. standard flashing
TECHNICAL DATA FOR ESTIMATING ASBESTOS ROOFING LENGTH
1.20 X 3.00 M.
END LAPPING : BELOW 20 DEGREES
.30 M.
ABOVE 20 DEGREES
.15 M.
EFFECTIVE WIDTH
.838 M.
RIDGE ROLL EFFECTIVE LENGTH
.838 M.
GUTTER EFFECTIVE LENGTH
2.336 M.
OUTSIDE FLASHING
2.286 M.
HIP ROLL
1.676 M.
STANDARD CORRUGATED SHEETS
CORRUGATED SHEET TECHNICAL DATA STANDARD LENGTH EFFECTIVE WIDTH RIDGE ROLL EFFECTIVE LENGTH OUTSIDE FLASHING EFFECTIVE LENGTH
2.438 METERS .965 METERS .965 METERS 2.286 METERS
KANALETAS ITEM
LENGTH IN METERS
LENGTH
7.315 M.
EFFECTIVE WIDTH
.885 M.
EAVES FLASHING
.885 M.
OUTSIDE FLASHING EFFECTIVE LENGTH
2.40 TO 3.00 M.
PLACA ROMANA ITEM STANDARD LENGTH EFFECTIVE LENGTH STANDARD WIDTH EFFECTIVE LENGTH END LAP SIDE LAP RIDGE ROLL EFFECTIVE LENGTH OUTSIDE FLASHING EFFECTIVE LENGTH RIDGE FLASHING EFFECTIVE LENGTH EAVES FLASHING EFFECTIVE LENGTH
LENGTH IN METERS .812 METERS .600 METERS 1.180 METERS 1.100 METERS .200 METERS .080 METERS 1.100 METERS 2.286 METERS 1.100 METERS 1.100 METERS
TENCOR CORRUGATED SHEET ITEMS LENGTH IN METERS STANDARD LENGTH
2.44 M.
LAPPING
.15 OR .30 M.
EFFECTIVE LENGTH
2.29 OR 2.14 M.
STANDARD WIDTH
.748 M.
EFFECTIVE WIDTH
.675 M.
OUTSIDE FLASHING
1.50 TO 3.00 M.
MINUS LAPPING
.15 M.
RIDGE ROLL
.953 M.
ARDEX CORRUGATED SHEET ITEM
MEASUREMENT STANDARD SUPER
STANDARD WIDTH
.52 M.
1.05 M.
EFFECTIVE WIDTH
.45 M.
NOMINAL LENGTH RIDGE ROLL EFFECTIVE LENGTH OUTSIDE FLASHING
.75 TO 3.15 M.
2.40 TO 3.60 M.
.95 M.
.95 M.
1.50 TO 2.00 M.
1.50 TO 3.00 M.
SIDE LAPPING
.15 M.
.15 M.
.97 M
COLORBOND KLIP-LOK is a corrosion resistant zinc coated steel sheet prepainted steel ribbed tray roofing and walling with the following special features. 1. Concealed fastening 2. Lock action rib design 3. Attractive fluted rays 4. Near flat roof slopes 5. Less supports-wider spaced 6. Strong lightweight steel 7. Custom cut long lengths
Colorbond Klip-lok STEEL BASE THICKNESS
0.60 MM
TOTAL COATED THICKNESS
0.63 MM
WEIGHT PER METER LENGTH OF PANEL
2.66 KG.
WEIGHT PER COVERED AREA
6.55 KG / M²
LENGTH AVAILABLE UP TO
15 METERS
LONGER LENGTH THROUGH SPECIAL ORDER UP TO
35 METERS
OVERALL WIDTH
.427 M.
EFFECTIVE WIDTH COVERAGE
.406 M.
RECOMMENDED FASTENERS (TWO FASTENERS REQUIRED PER CLIP) SUPPORT MEMBER
NORMAL FASTENING
FASTENING OVER INSULATION UP TO 100 MM (4”)
STEEL UP TO 3/32” (2.5MM) THICK
NO. 10-16 X 5/8” WAFER HEAD SELF DRILLING AND TAPPING SCREW
NO. 10-16 X 7/8” (22 MM) WAFER HEAD SELF DRILLING AND TAPPING SCREW
STEEL 3/32” TO 3/16 2.5 – 5 MM THICK
NO. 10-24 X 5/8” WAFER HEAD SELF DRILLING AND TAPPING SCREW
NO. 10-24 X 7/8 (22 MM) WAFER HEAD SELF DRILLING AND TAPPING SCREW
STEEL OVER 3/16 (5MM THICK)
NO. 10-24 X 5/8” WAFER HEAD THREAD CUTTING SCREW. DRILL 4.5 MM
NO. 10-24 X 7/8 (22 MM) HOLE FOR NO. 10-24 X 7/8” WAFER HEAD SELF DRILLING AND TAPPING SCREW
HARDWOOD
SOFTWOOD
2” X 9 G (50 X 3.75 MM) COUNTER 2 1/2 “ X 9 G (60 X 3.75 MM) COUNTER SUNK HEAD G.I. SPIRAL NAIL OR NO. 10- SUNK HEAD G.I. SPIRAL NAIL OR NO. 10 12 X 1” (25 MM) TYPE 17 WAFER HEAD – 12 X 1 3/4 “ (45 MM) TYPE 17 WAFER SELF DRILLING WOOD SCREW HEAD SELF DRILLING WOOD SCREW
NO. 10-12 X 1 3/4 “ TYPE 17 WAFER HEAD SELF DRILLING WOOD SCREW
NO.10-12 X 1 3/4 “ (45MM) TYPE 17 WAFER HEAD SELF DRILLING WOOD SCREW
BANAWE HORIZONTAL METAL TILE
Technical Data NOMINAL WIDTH
.228 M.
EFFECTIVE WIDTH COVERAGE
.204 M.
LENGTH
12.19 M.
MINIMUM ROOF SLOPE
15 DEGREES
MARCELO ROOFING SYSTEM
Technical Data WIDTH LENGTH EFFECTIVE WIDTH COVERAGE EFFECTIVE AREA COVERAGE PER SHEET NUMBER OF FASTENER PER SHEET FIRST ROW SUCCEEDING ROWS AVERAGE NO. OF FASTENERS PER SHEET
1.14 M. 1.11 M. .95 M. .92 SQ. M. 15 PCS. PER SHEET 10 PCS. PER SHEET 12 PCS. PER SHEET
COLORBOND CUSTOM ORB
Technical Data
.86 M. NORMAL WIDTH .76 M. EFFECTIVE COVERAGE 1.35 M. LENGTH SPECIAL ORDER LONGER LENGTH MAXIMUM RECOMMENDED LENGTH FOR CONTINUOUS SHEET WITHOUT EXPANSION JOINTS 24 M.
MILANO LONGSPAN STEEL BRICKS
Technical Data STEEL BASE THICKNESS (NO. 26) TOTAL COATED THICKNESS
0.40 MM. 0.46 MM
WEIGHT PER SQ. M.
4.53 KG.
WEIGHT PER LENGTH
3.44 KG.
EFFECTIVE COVERAGE
0.67 M.
LENGTH UP TO
6.00 M.
LONGER LENGTH RECOMMENDED ROOF SLOPE
SPECIAL ORDER 10° MIN.
COLORBOND TREMDEX HI-TEN
Technical Data
STEEL BASE THICKNESS
0.40 M.
TOTAL COATED THICKNESS
0.46 M.
WEIGHT
PER UNIT AREA
4.28 KG. / SQ. M.
PER UNIT LENGTH
3.26 KG. / SQ. M.
NORMAL WIDTH EFFECTIVE WIDTH COVERAGE AVAILABLE LENGTH UP TO LONGER LENGTH MINIMUM SLOPE SINGLE SHEET ROOF WITH END LAP
0.83 M. 0.76M. 15 M. SPECIAL ORDER 3 DEGREES 5 DEGREES
Fasteners : For Hardwood: Use Type 17 self drilling wood screw No. 12 x 50 mm. hexagonal head with neoprene washer. For Softwood: Add 12 mm to length of screw. There should be four fasteners per sheet at all supports. For side lap fastener, use Type S point self drilling screw No. 10 x 16 mm. hexagonal head with neoprene washers. Teks self drilling screw to steel support up to 4.5 mm. thick use No. 12 x 45
BRICK TILE ROOFING
Technical Data : DESCRIPTION
WEIGHT PER PLACE IN KILOGRAMS
NUMBER REQUIRED
MARCEILLE TYPE (FLAT) ONDULA TYPE (WAVY) SR. ( STANDARD RIDGE) HALF MARCEILLE JRT – 1 JRT – 2 JRT – 3 JRT – 4 JRT – 5 SRT – 1 SRT – 2 SRT – L SRT – R JSR – 1 JSR – 2 SRT – U SRT – T
3.60 4.00 2.80 2.00 3.00 3.75 3.20 3.20 2.20 4.00 2.20 2.25 2.25 2.00 3.00 1.75 1.50
14.0 PER SQ. M. 15.0 PER SQ. M. 2.5 PER LN. M. 1.0 PER LN. M. 13.0 PER SQ. M. 4.0 PER SQ. M. 1.0 PER LN. M. 1.0 PER LN. M. 4.0 PER LN. M. 13.0 PER SQ. M. 1.0 PER LN. M. 1.0 PER LN. M. 1.0 PER LN. M. 1.0 PER LN. M. 4.0 PER LN. M. 25.0 PER SQ. M. 25.0 PER SQ. M.